While modeling a power supply system for an electric railway traction, knowing equivalent circuits of locomotives supplied this way is an essential issue. In alternating current traction, it is important to diagnose i...While modeling a power supply system for an electric railway traction, knowing equivalent circuits of locomotives supplied this way is an essential issue. In alternating current traction, it is important to diagnose inter alia processes taking place in transformers installed on electric vehicles. This article presents specific phenomena occurring during the work of mono-phase, multi-winding, multisystem (systems AC: 50 Hz, 16.7 Hz) laboratory traction transformer. It also shows difficulties encountered during the process of identifying multi-port equivalent scheme's elements of the described device, in which a construction defect occurs.展开更多
This work is aimed at developing an effective method for defect recognition in thermosonic imaging.The heat mechanism of thermosonic imaging is introduced,and the problem for defect recognition is discussed.For this p...This work is aimed at developing an effective method for defect recognition in thermosonic imaging.The heat mechanism of thermosonic imaging is introduced,and the problem for defect recognition is discussed.For this purpose,defect existing in the inner wall of a metal pipeline specimen and defects embedded in a carbon fiber reinforced plastic(CFRP) laminate are tested.The experimental data are processed by pulse phase thermography(PPT) method to show the phase images at different frequencies,and the characteristic of phase angle vs frequency curve of thermal anomalies and sound area is analyzed.A binary image,which is based on the characteristic value of defects,is obtained by a new recognition algorithm to show the defects.Results demonstrate good defect recognition performance for thermosonic imaging,and the reliability of this technique can be improved by the method.展开更多
文摘While modeling a power supply system for an electric railway traction, knowing equivalent circuits of locomotives supplied this way is an essential issue. In alternating current traction, it is important to diagnose inter alia processes taking place in transformers installed on electric vehicles. This article presents specific phenomena occurring during the work of mono-phase, multi-winding, multisystem (systems AC: 50 Hz, 16.7 Hz) laboratory traction transformer. It also shows difficulties encountered during the process of identifying multi-port equivalent scheme's elements of the described device, in which a construction defect occurs.
基金Joint Funds of the National Natural Science Foundationof China (61079020)
文摘This work is aimed at developing an effective method for defect recognition in thermosonic imaging.The heat mechanism of thermosonic imaging is introduced,and the problem for defect recognition is discussed.For this purpose,defect existing in the inner wall of a metal pipeline specimen and defects embedded in a carbon fiber reinforced plastic(CFRP) laminate are tested.The experimental data are processed by pulse phase thermography(PPT) method to show the phase images at different frequencies,and the characteristic of phase angle vs frequency curve of thermal anomalies and sound area is analyzed.A binary image,which is based on the characteristic value of defects,is obtained by a new recognition algorithm to show the defects.Results demonstrate good defect recognition performance for thermosonic imaging,and the reliability of this technique can be improved by the method.