期刊文献+
共找到475篇文章
< 1 2 24 >
每页显示 20 50 100
Achieving 2.1%Effciency in Alpha-Voltaic Cell Based on Silicon Carbide Transducer
1
作者 Runlong Gao Wuying Ma +7 位作者 Pengying Wan Ao Liu Xiao Ouyang Xue Du Qiantao Lei Qi Deng Linyue Liu Xiaoping Ouyang 《Energy & Environmental Materials》 2025年第2期305-311,共7页
Alpha-voltaic cell is a type of micro nuclear battery that provides several decades of reliable power in the nano watt to microwatt range,supplying for special applications where traditional chemical batteries or sola... Alpha-voltaic cell is a type of micro nuclear battery that provides several decades of reliable power in the nano watt to microwatt range,supplying for special applications where traditional chemical batteries or solar cells are difficult to operate.However,the power conversion efficiency of the alpha-voltaic cells reported are still far behind the theoretical limit,making the development of alpha-voltaic cell challenging.Developing advanced semiconductor transducers with higher efficiency in converting the energy of alpha particles into electric energy is proving to be necessary for realizing high-power conversion efficiency.Herein,we propose an alpha-voltaic cell based on SiC PIN transducer that includes a sensitive region with an area of 1 cm^(2),a width of 51.2μm,and a charge collection efficiency of 95.6%at 0 V bias.We find that optimizing the unintentional doping concentration and crystal quality of the SiC epitaxial layer can significantly increase the absorption and utilization of the energy of alpha particles,resulting in a 2.4-fold enhancement in power conversion efficiency compared with that of the previous study.Electrical properties of the SiC alpha-voltaic cell are measured using an He-ion accelerator as the equivalentα-radioisotopes,with the best power conversion efficiency of 2.10%and maximum output power density of 406.66 nW cm-2 is obtained.Our research makes a big leap in SiC alpha-voltaic cell,bridging the gap between micro nuclear batteries and practical applications in micro-electromechanical systems,micro aerial vehicles,and tiny satellites. 展开更多
关键词 alpha-voltaiccell high-powerconversionefficiency nuclearbattery SiCPIN transducer
在线阅读 下载PDF
Generation of acoustical Bessel-like collimated beams using ring-excited flat plate structure transducers
2
作者 Ming-Liang Han Ruo-Yu Tang +2 位作者 Ning Ma Guang-Bin Zhang Xiao-Feng Zhang 《Chinese Physics B》 2025年第4期377-385,共9页
This paper proposes a method to generate Bessel-like collimated beams with suppressed side lobes using the flexural vibration modes of a fixed boundary circular plate,which is excited by a longitudinally vibrating tra... This paper proposes a method to generate Bessel-like collimated beams with suppressed side lobes using the flexural vibration modes of a fixed boundary circular plate,which is excited by a longitudinally vibrating transducer in a ring excitation manner.The factors affecting the generation of Bessel-like collimated beams are investigated by theoretical analysis,numerical simulation and experimental methods.The results indicate that Bessel-like wave can be generated by a thin circular plate with fixed boundaries.The third-order mode of the circular plate can be modified to generate a collimated beam with suppressing side lobes when it is excited in a ring excitation manner and the excitation position lies between the first two nodal circles of the plate.As the excitation radius increases,the main lobe width of the resulting Bessel-like collimated beam decreases,the extent of the focusing region increases,and the amplitude of the side lobes initially increases and then decreases.Based on the simulation results,a prototype Bessel-like collimated beam generation system is made and measured experimentally.The experimental results are in good agreement with the numerical results.The Bessel-like collimated beam can be generated by the proposed system,which has potential application in the fields of long-range detection,imaging of highly attenuated materials,and airflow acceleration. 展开更多
关键词 Bessel-like collimated beams flat plate structure transducers flexural vibration ring-excited
原文传递
Non-contact air-coupled transducers Lamb wave signal multipath effect and blind separation for different modes using PZT as receiver 被引量:1
3
作者 Desheng WU Zhibo YANG +3 位作者 Yu RUAN Wenbo LI Lijuan YANG Xuefeng CHEN 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2024年第10期424-434,共11页
Due to the complexity and faintness of the detection wave patterns obtained by aircoupled transducers,if it is possible to effectively separate the various modes and obtain nondispersive signals for more accurate dete... Due to the complexity and faintness of the detection wave patterns obtained by aircoupled transducers,if it is possible to effectively separate the various modes and obtain nondispersive signals for more accurate detection and positioning,it will help to improve the accuracy and reliability of air-coupled ultrasonic Lamb wave detection,providing better technical support for the application and development of related fields.Because of the increased complexity of aircoupled signals,there is no definite theoretical formula to describe the mode changes of aircoupled signals,so the method based on blind separation has unique value.To address these challenges,the paper proposes a single-channel blind source separation(SCBSS)method.The effectiveness of this method is evaluated through simulations and experiments,demonstrating favorable separation results and efficient computational speed.This work first conducts an in-depth analysis of the signal characteristics of air-coupled ultrasonic non-destructive testing,and simulates the ultrasonic excitation conditions of air-coupled sensors through finite element software.The study of modal changes and multipath effects caused by the variation of the incidence angle of the ACT signal is carried out,and the situation of the Lamb wave signal excited by ACT at the receiving end is analyzed.By combining ACT with PZT signals,the ultrasonic signals of air-coupled Lamb waves are compared and studied,and their modal purification is carried out. 展开更多
关键词 Air-coupled transducers Lamb wave Mode separation Blind source separation Non-destructive testing
原文传递
Effects of interleukin-10 treated macrophages on bone marrow mesenchymal stem cells via signal transducer and activator of transcription 3 pathway
4
作者 Meng-Hao Lyu Ce Bian +3 位作者 Yi-Ping Dou Kang Gao Jun-Ji Xu Pan Ma 《World Journal of Stem Cells》 SCIE 2024年第5期560-574,共15页
BACKGROUND Alveolar bone defects caused by inflammation are an urgent issue in oral implant surgery that must be solved.Regulating the various phenotypes of macrophages to enhance the inflammatory environment can sign... BACKGROUND Alveolar bone defects caused by inflammation are an urgent issue in oral implant surgery that must be solved.Regulating the various phenotypes of macrophages to enhance the inflammatory environment can significantly affect the progression of diseases and tissue engineering repair process.AIM To assess the influence of interleukin-10(IL-10)on the osteogenic differentiation of bone marrow mesenchymal stem cells(BMSCs)following their interaction with macrophages in an inflammatory environment.METHODS IL-10 modulates the differentiation of peritoneal macrophages in Wistar rats in an inflammatory environment.In this study,we investigated its impact on the proliferation,migration,and osteogenesis of BMSCs.The expression levels of signal transducer and activator of transcription 3(STAT3)and its activated form,phos-phorylated-STAT3,were examined in IL-10-stimulated macrophages.Subsequently,a specific STAT3 signaling inhibitor was used to impede STAT3 signal activation to further investigate the role of STAT3 signaling.RESULTS IL-10-stimulated macrophages underwent polarization to the M2 type through substitution,and these M2 macrophages actively facilitated the osteogenic differentiation of BMSCs.Mechanistically,STAT3 signaling plays a crucial role in the process by which IL-10 influences macrophages.Specifically,IL-10 stimulated the activation of the STAT3 signaling pathway and reduced the macrophage inflammatory response,as evidenced by its diminished impact on the osteogenic differentiation of BMSCs.CONCLUSION Stimulating macrophages with IL-10 proved effective in improving the inflammatory environment and promoting the osteogenic differentiation of BMSCs.The IL-10/STAT3 signaling pathway has emerged as a key regulator in the macrophage-mediated control of BMSCs’osteogenic differentiation. 展开更多
关键词 MACROPHAGES INTERLEUKIN-10 Bone marrow mesenchymal stem cells Signal transducer and activator of transcription 3 Inflammatory response
暂未订购
Design and micromanufacturing technologies of focused piezoelectric ultrasound transducers for biomedical applications
5
作者 Xingyu Bai Daixu Wang +5 位作者 Liyun Zhen Meng Cui Jingquan Liu Ning Zhao Chengkuo Lee Bin Yang 《International Journal of Extreme Manufacturing》 CSCD 2024年第6期24-48,共25页
Piezoelectric ultrasonic transducers have shown great potential in biomedical applications due to their high acoustic-to-electric conversion efficiency and large power capacity.The focusing technique enables the trans... Piezoelectric ultrasonic transducers have shown great potential in biomedical applications due to their high acoustic-to-electric conversion efficiency and large power capacity.The focusing technique enables the transducer to produce an extremely narrow beam,greatly improving the resolution and sensitivity.In this work,we summarize the fundamental properties and biological effects of the ultrasound field,aiming to establish a correlation between device design and application.Focusing techniques for piezoelectric transducers are highlighted,including material selection and fabrication methods,which determine the final performance of piezoelectric transducers.Numerous examples,from ultrasound imaging,neuromodulation,tumor ablation to ultrasonic wireless energy transfer,are summarized to highlight the great promise of biomedical applications.Finally,the challenges and opportunities of focused ultrasound transducers are presented.The aim of this review is to bridge the gap between focused ultrasound systems and biomedical applications. 展开更多
关键词 piezoelectric ultrasonic transducers focusing techniques preparation method biomedical applications
在线阅读 下载PDF
Combined Digital Electronic Current and Voltage Transducer 被引量:2
6
作者 段雄英 邹积岩 +1 位作者 廖敏夫 张可卫 《Journal of Shanghai University(English Edition)》 CAS 2002年第1期79-84,共6页
A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil ... A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements. Active electronic components are used to modulate signal, and power supply for these components is drawn from power line via an auxiliary current transformer. Measurement signal is transmitted by optical fibers, which is resistant to electromagnetic induction and noise. With careful design and the use of digital signal processing technology, the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use. 展开更多
关键词 electronic current transducer (ECT) electronic voltage transducer (EVT) Rogowski coil capacitive voltage divider (CVD) optical fiber.
在线阅读 下载PDF
Diffusion-weighted magnetic resonance imaging reflects activation of signal transducer and activator of transcription 3 during focal cerebral ischemia/reperfusion 被引量:2
7
作者 Wen-juan Wu Chun-juan Jiang +2 位作者 Zhui-yang Zhang Kai Xu Wei Li 《Neural Regeneration Research》 SCIE CAS CSCD 2017年第7期1124-1130,共7页
Signal transducer and activator of transcription(STAT)is a unique protein family that binds to DNA,coupled with tyrosine phosphorylation signaling pathways,acting as a transcriptional regulator to mediate a variety ... Signal transducer and activator of transcription(STAT)is a unique protein family that binds to DNA,coupled with tyrosine phosphorylation signaling pathways,acting as a transcriptional regulator to mediate a variety of biological effects.Cerebral ischemia and reperfusion can activate STATs signaling pathway,but no studies have confirmed whether STAT activation can be verified by diffusion-weighted magnetic resonance imaging(DWI)in rats after cerebral ischemia/reperfusion.Here,we established a rat model of focal cerebral ischemia injury using the modified Longa method.DWI revealed hyperintensity in parts of the left hemisphere before reperfusion and a low apparent diffusion coefficient.STAT3 protein expression showed no significant change after reperfusion,but phosphorylated STAT3 expression began to increase after 30 minutes of reperfusion and peaked at 24 hours.Pearson correlation analysis showed that STAT3 activation was correlated positively with the relative apparent diffusion coefficient and negatively with the DWI abnormal signal area.These results indicate that DWI is a reliable representation of the infarct area and reflects STAT phosphorylation in rat brain following focal cerebral ischemia/reperfusion. 展开更多
关键词 nerve regeneration cerebral ischemia/repe(fusion magnetic resonance imaging diffusion weighted imaging signal transducer and activator of transcription 3 phosphorylated signal transducer and activator of transcription 3 apparent diffusion coefficient relative apparentdiffusion coefficient IMMUNOHISTOCHEMISTRY western blot assay neural regeneration
暂未订购
Genetic Algorithm-Based Estimation of Nonlinear Transducer
8
作者 庄哲民 黄惟一 《Journal of Southeast University(English Edition)》 EI CAS 2001年第1期4-7,共4页
This paper describes an innovative, genetic algorithm based inverse model of nonlinear transducer. In the inverse modeling, using a genetic algorithm, the unknown coefficients of the model are estimated accurately. T... This paper describes an innovative, genetic algorithm based inverse model of nonlinear transducer. In the inverse modeling, using a genetic algorithm, the unknown coefficients of the model are estimated accurately. The simulation results indicate that this technique provides greater flexibility and suitability than the existing methods. It is very easy to modify the nonlinear transducer on line. Thus the method improves the transducer's accuracy. With the help of genetic algorithm (GA), the model coefficients' training are less likely to be trapped in local minima than traditional gradient based search algorithms. 展开更多
关键词 nonlinear transducer genetic algorithm inverse model
在线阅读 下载PDF
Excitation and Detection of Shear Horizontal Waves with Electromagnetic Acoustic Transducers for Nondestructive Testing of Plates 被引量:14
9
作者 MA Qingzeng JIAO Jingpin +3 位作者 HU Ping ZHONG Xi WU Bin HE Cunfu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第2期428-436,共9页
The fundamental shear horizontal(SH0) wave has several unique features that are attractive for long-range nondestructive testing(NDT). By a careful design of the geometric configuration, electromagnetic acoustic t... The fundamental shear horizontal(SH0) wave has several unique features that are attractive for long-range nondestructive testing(NDT). By a careful design of the geometric configuration, electromagnetic acoustic transducers(EMATs) have the capability to generate a wide range of guided wave modes, such as Lamb waves and shear-horizontal(SH) waves in plates. However, the performance of EMATs is influenced by their parameters. To evaluate the performance of periodic permanent magnet(PPM) EMATs, a distributed-line-source model is developed to calculate the angular acoustic field cross-section in the far-field. Numerical analysis is conducted to investigate the performance of such EMATs with different geometric parameters, such as period and number of magnet arrays, and inner and outer coil widths. Such parameters have a great influence on the directivity of the generated SH0 waves that arises mainly in the amplitude and width of both main and side lobes. According to the numerical analysis, these parameters are optimized to obtain better directivity. Optimized PPM EMATs are designed and used for NDT of strip plates. Experimental results show that the lateral boundary of the strip plate has no perceivable influence on SHO-wave propagation, thus validating their used in NDT. The proposed model predicts the radiation pattern ofPPM EMATs, and can be used for their parameter optimization. 展开更多
关键词 electromagnetic acoustic transducers shear-horizontal waves strip plate nondestructive testing
在线阅读 下载PDF
Regulation and function of signal transducer and activator of transcription 3 被引量:24
10
作者 Qian-Rong Qi Zeng-Ming Yang 《World Journal of Biological Chemistry》 CAS 2014年第2期231-239,共9页
Signal transducer and activator of transcription 3(STAT3), a member of the STAT family, is a key regulator of many physiological and pathological processes. Significant progress has been made in understanding the tran... Signal transducer and activator of transcription 3(STAT3), a member of the STAT family, is a key regulator of many physiological and pathological processes. Significant progress has been made in understanding the transcriptional control, posttranslational modification, cellular localization and functional regulation of STAT3. STAT3 can translocate into the nucleus and bind to specific promoter sequences, thereby exerting transcriptional regulation. Recent studies have shown that STAT3 can also translocate into mitochondria, participating in aerobic respiration and apoptosis. In addition, STAT3 plays an important role in inflammation and tumorigenesis by regulating cell proliferation, differentiation and metabolism. Conditional knockout mouse models make it possible to study the physiological function of STAT3 in specific tissues and organs. This review summarizes the latest advances in the understanding of the expression, regulation and function of STAT3 in physiological and tumorigenic processes. 展开更多
关键词 SIGNAL transduceR and ACTIVATOR of TRANSCRIPTION 3 PHOSPHORYLATION ACETYLATION SIGNAL pathway Tumor
暂未订购
Modeling and finite element analysis of transduction process of electromagnetic acoustic transducers for nonferromagnetic metal material testing 被引量:14
11
作者 郝宽胜 黄松岭 +2 位作者 赵伟 段汝娇 王珅 《Journal of Central South University》 SCIE EI CAS 2011年第3期749-754,共6页
Facing the problems lack of considering the non-uniform distribution of the static bias magnetic field and computing the panicle displacements in the simulation model of electromagnetic acoustic transducer (EMAT), a... Facing the problems lack of considering the non-uniform distribution of the static bias magnetic field and computing the panicle displacements in the simulation model of electromagnetic acoustic transducer (EMAT), a multi-field coupled model was established and the finite element method (FEM) was presented to calculate the entire transduction process. The multi-field coupled model included the static magnetic field, pulsed eddy current field and mechanical field. The FEM equations of the three fields were derived by Garlerkin FEM method. Thus, the entire transduction process of the EMAT was calculated through sequentially coupling the three fields. The transduction process of a Lamb wave EMAT was calculated according to the present model and method. The results show that, by the present method, it is valid to calculate the particle displacement under the given excitation signal and non-uniformly distributed static magnetic field. Calculation error will be brought about if the non-uniform distribution of the static bias magnetic field is neglected. 展开更多
关键词 metal material nondestructive testing electromagnetic acoustic transducer multi-field coupling Garlerkin method finite element
在线阅读 下载PDF
Signal transducer and activator of transcription 3 promotes the Warburg effect possibly by inducing pyruvate kinase M2 phosphorylation in liver precancerous lesions 被引量:10
12
作者 Yang-Hui Bi Wen-Qi Han +4 位作者 Ruo-Fei Li Yun-Jiao Wang Zun-Shu Du Xue-Jiang Wang Ying Jiang 《World Journal of Gastroenterology》 SCIE CAS 2019年第16期1936-1949,共14页
BACKGROUND Study shows that signal transducer and activator of transcription 3(STAT3) can increase the Warburg effect by stimulating hexokinase 2 in breast cancer and upregulate lactate dehydrogenase A and pyruvate de... BACKGROUND Study shows that signal transducer and activator of transcription 3(STAT3) can increase the Warburg effect by stimulating hexokinase 2 in breast cancer and upregulate lactate dehydrogenase A and pyruvate dehydrogenase kinase 1 in myeloma. STAT3 and pyruvate kinase M2(PKM2) can also be activated and enhance the Warburg effect in hepatocellular carcinoma. Precancerous lesions are critical to human and rodent hepatocarcinogenesis. However, the underlying molecular mechanism for the development of liver precancerous lesions remains unknown. We hypothesized that STAT3 promotes the Warburg effect possibly by upregulating p-PKM2 in liver precancerous lesions in rats.AIM To investigate the mechanism of the Warburg effect in liver precancerous lesions in rats.METHODS A model of liver precancerous lesions was established by a modified Solt-Farber method. The liver pathological changes were observed by HE staining and immunohistochemistry. The transformation of WB-F344 cells induced with Nmethyl-N'-nitro-N-nitrosoguanidine and hydrogen peroxide was evaluated by the soft agar assay and aneuploidy. The levels of glucose and lactate in the tissue and culture medium were detected with a spectrophotometer. The protein levels of glutathione S-transferase-π, proliferating cell nuclear antigen(PCNA), STAT3,and PKM2 were examined by Western blot and immunofluorescence.RESULTS We found that the Warburg effect was increased in liver precancerous lesions in rats. PKM2 and p-STAT3 were upregulated in activated oval cells in liverprecancerous lesions in rats. The Warburg effect, p-PKM2, and p-STAT3 expression were also increased in transformed WB-F344 cells. STAT3 activation promoted the clonal formation rate, aneuploidy, alpha-fetoprotein expression,PCNA expression, G1/S phase transition, the Warburg effect, PKM2 phosphorylation, and nuclear translocation in transformed WB-F344 cells.Moreover, the Warburg effect was inhibited by stattic, a specific inhibitor of STAT3, and further reduced in transformed WB-F344 cells after the intervention for PKM2.CONCLUSION The Warburg effect is initiated in liver precancerous lesions in rats. STAT3 activation promotes the Warburg effect by enhancing the phosphorylation of PKM2 in transformed WB-F344 cells. 展开更多
关键词 WARBURG effect Hepatic PROGENITOR cell Signal transducer and activator of transcription 3 PYRUVATE kinase M2 LIVER PRECANCEROUS lesion
暂未订购
Ultrasound Imaging of Pipeline Crack Based on Composite Transducer Array 被引量:8
13
作者 Shou-Peng Song Ying-Jie Ni 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第5期25-34,共10页
Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. There... Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. Therefore, a new com?posite ultrasonic transducer array with three acoustic beam incidence modes is developed. The space model of the array is also established to obtain the defect reflection point location. And the crack ultrasound image is thus formed through a series of small cubical elements expanded around the point locations by using the projection of binariza?tion values extracted from the received ultrasonic echo signals. Laboratory experiments are performed on a pipeline sample with di erent types of cracks to verify the e ectiveness and performance of the proposed technique. From the image, the presence of small cracks can be clearly observed, in addition to the sizes and orientations of the cracks. The proposed technique can not only inspect common flaws, but also detect cracks with various orientations, which is helpful for defect evaluation in pipeline testing. 展开更多
关键词 Composite transducer array Ultrasound imaging CRACK NDT&E
在线阅读 下载PDF
OPTIMAL DESIGN OF A 6-AXIS FORCE TRANSDUCER BASED ON STEWART PLATFORM RELATED TO SENSITIVITY ISOTROPY 被引量:10
14
作者 JinZhenlin GaoFenfl GaoFeng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2003年第2期146-148,共3页
The design method of a 6-axis force robot's transducer based on the Stewartplatform is detailed. For this purpose, the sensitivity isotropy evaluation criteria of thetransducer are defined, and by the aid of compu... The design method of a 6-axis force robot's transducer based on the Stewartplatform is detailed. For this purpose, the sensitivity isotropy evaluation criteria of thetransducer are defined, and by the aid of computer, the relationships between the criteria and theparameters of all the transducers based on the Stewart platform are investigated within thegeometric model of the solution space, which can provide the theoretical background for the optimalconstruction design of the 6-axis force transducer related to the sensitivity isotropy. 展开更多
关键词 6-axis force robot's transducer optimal construction design stewartplatform sensitivity isotropy
在线阅读 下载PDF
Downregulation of signal transducer and activator of transcription 3 by sorafenib:A novel mechanism for hepatocellular carcinoma therapy 被引量:10
15
作者 Man-Hsin Hung Wei-Tien Tai +1 位作者 Chung-Wai Shiau Kuen-Feng Chen 《World Journal of Gastroenterology》 SCIE CAS 2014年第41期15269-15274,共6页
Hepatocellular carcinoma is one of the most common cancers worldwide,and a leading cause of cancer-related death.Owing to unsatisfactory clinical outcomes under the current standard of care,there is a need to search f... Hepatocellular carcinoma is one of the most common cancers worldwide,and a leading cause of cancer-related death.Owing to unsatisfactory clinical outcomes under the current standard of care,there is a need to search for and identify novel and potent therapeutic targets to improve patient outcomes.Sorafenib is the first and only approved targeted therapy for the treatment of hepatocellular carcinoma.Besides functioning as a multiple tyrosine kinase,sorafenib also acts via a kinase-independent mechanism to target signal transducer and activator of transcription 3(STAT3) signaling in hepatocellular carcinoma cells.STAT3 is a key regulator of inflammation,cell survival,and tumorigenesis of liver cells,and the high percentage of hepatocellular carcinoma cells with constitutively active STAT3 justifies targeting it for the development of novel therapeutics.Sorafenib inactivates STAT3 and STAT3-related signaling by inducing a conformational change in and releasing the autoinhibition of Src homology region 2 domaincontaining phosphatase-1.This phosphatase negatively regulates STAT3 activity,which leads to the subsequent apoptosis of cancer cells.The novel anti-cancer property of sorafenib will be discussed in this review,not only adding information regarding its mechanism of action but also providing an innovative approach for the development of cancer therapeutics in the future. 展开更多
关键词 Hepatocellular carcinoma SORAFENIB Signal transducer and activator of transcription 3 Target therapy Kinase-independent
暂未订购
Resonant frequencies of a piezoelectric drum transducer 被引量:6
16
作者 Jiang-bo YUAN Tao XIE +1 位作者 Xiao-biao SHAN Wei-shan CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第9期1313-1319,共7页
This paper presents a piezoelectric-metal structure called a drum transducer. An equation for calculating the resonance frequency of the drum transducer is obtained based on thin plate elastic theory of piezoelectric ... This paper presents a piezoelectric-metal structure called a drum transducer. An equation for calculating the resonance frequency of the drum transducer is obtained based on thin plate elastic theory of piezoelectric and metal material combined with the Rayleigh-Ritz method. The finite element method (FEM) was used to predict the excitation frequency of the drum transducer. To verify the theoretical analysis, the input impedance characteristic of the drum transducer was measured using an experimental method. The results obtained from theoretical analysis were in very good agreement with those from the FEM and experimental results. The effect of geometrical changes to the thick-walled steel ring of the drum transducer at the first resonance frequency is also described. The calculated results were found to be in good agreement with the FEM results. The results indicate that the first resonance frequency of the drum decreases with the increasing inner diameter of the thick-walled steel ring. 展开更多
关键词 PIEZOELECTRIC Drum transducer Resonance frequency
原文传递
Hybrid calibration method for six-component force/torque transducers of wind tunnel balance based on support vector machines 被引量:4
17
作者 Ma Yingkun Xie Shilin +1 位作者 Zhang Xinong Luo Yajun 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第3期554-562,共9页
A hybrid calibration approach based on support vector machines (SVM) is proposed to characterize nonlinear cross coupling of multi-dimensional transducer. It is difficult to identify these unknown nonlinearities and... A hybrid calibration approach based on support vector machines (SVM) is proposed to characterize nonlinear cross coupling of multi-dimensional transducer. It is difficult to identify these unknown nonlinearities and crosstalk just with a single conventional calibration approach. In this paper, a hybrid model comprising calibration matrix and SVM model for calibrating linearity and nonlinearity respectively is built up. The calibration matrix is determined by linear artificial neural network (ANN), and the SVM is used to compensate for the nonlinear cross coupling among each dimension. A simulation of the calibration of a multi-dimensional sensor is conducted by the SVM hybrid calibration method, which is then utilized to calibrate a six-component force/torque transducer of wind tunnel balance. From the calibrating results, it can be indicated that the SVM hybrid calibration method has improved the calibration accuracy significantly without increasing data samples, compared with calibration matrix. Moreover, with the calibration matrix, the hybrid model can provide a basis for the design of transducers. 展开更多
关键词 HYBRID MULTI-DIMENSIONAL Nonlinear coupling Support vector machines transducers
原文传递
Simulation of thermal field induced by concave spherical transducer in multi-layer media 被引量:5
18
作者 丁亚军 钱盛友 廖志远 《Journal of Central South University》 SCIE EI CAS 2013年第11期3166-3170,共5页
High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,tempe... High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,temperature field induced by this kind of transducer in multi-layer media will be simulated through solving Pennes equation with finite difference method,and the influence of initial sound pressure,absorption coefficient,and thickness of different layers of biological tissue as well as thermal conductivity parameter on sound focus and temperature distribution will be analyzed,respectively.The results show that the temperature in focus area increases faster while the initial sound pressure and thermal conductivity increase.The absorption coefficient is smaller,the ultrasound intensity in the focus area is bigger,and the size of the focus area is increasing.When the thicknesses of different layers of tissue change,the focus position changes slightly,but the sound intensity of the focus area will change obviously.The temperature in focus area will rise quickly before reaching a threshold,and then the temperature will keep in the threshold range. 展开更多
关键词 multi-layer media concave spherical transducer high intensity focused ultrasound thermal field
在线阅读 下载PDF
A Novel Traveling Wave Ultrasonic Motor Using a Bar Shaped Transducer 被引量:4
19
作者 金家楣 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第6期961-963,共3页
A novel traveling wave ultrasonic motor was proposed. The structure of the motor is rather simple and different from the conventional traveling wave ultrasonic motors. Its production processes are very convenient. It ... A novel traveling wave ultrasonic motor was proposed. The structure of the motor is rather simple and different from the conventional traveling wave ultrasonic motors. Its production processes are very convenient. It is composed of a stator constituted with a ring and a bar shaped transducer and two cone shaped rotors. The rotors were pressed on inner surface of the ring by means of a pre-pressure system. The bar shaped transducer has a sand- wich-like configuration,where two sets of piezoelectric element are bolted. One set excites a longitudinal vibration of the bar, and the other set excites a flexural vibration of the bar. The ring's traveling wave excited with the longitudinal vibration and the bending vibration of the bar transducer was simulated with FEM (finite element method). The prototype of the motor was made and investigated experimentally for its performance. Its maximum torque and rotating speed are 0.25 N · m and 50 r/min, respectively. 展开更多
关键词 ultrasonic motor traveling wave bar transducer
原文传递
Design of a hexagonal air-coupled capacitive micromachined ultrasonic transducer for air parametric array 被引量:5
20
作者 Xiaoli Zhang Hui Zhang Dachao Li 《Nanotechnology and Precision Engineering》 CAS CSCD 2021年第1期26-35,共10页
An air parametric array can generate a highly directional beam of audible sound in air,which has a wide range of applications in targeted audio delivery.Capacitive micromachined ultrasonic transducer(CMUTs)have great ... An air parametric array can generate a highly directional beam of audible sound in air,which has a wide range of applications in targeted audio delivery.Capacitive micromachined ultrasonic transducer(CMUTs)have great potential for air-coupled applications,mainly because of their low acoustic impedance.In this study,an air-coupled CMUT array is designed as an air parametric array.A hexagonal array is proposed to improve the directivity of the sound generated.A finite element model of the CMUT is established in COMSOL software to facilitate the choice of appropriate structural parameters of the CMUT cell.The CMUT array is then fabricated by a wafer bonding process with high consistency.The performances of the CMUT are tested to verify the accuracy of the finite element analysis.By optimizing the component parameters of the bias-T circuit used for driving the CMUT,DC and AC voltages can be effectively applied to the top and bottom electrodes of the CMUT to provide efficient ultrasound transmission.Finally,the prepared hexagonal array is successfully used to conduct preliminary experiments on its application as an air parametric array. 展开更多
关键词 Capacitive micromachined ultrasonic transducer Air–coupled Wafer bonding process Bias-T circuit optimization Parametric array
在线阅读 下载PDF
上一页 1 2 24 下一页 到第
使用帮助 返回顶部