期刊文献+
共找到562篇文章
< 1 2 29 >
每页显示 20 50 100
Experimental Observing Damage Evolution in Cement Pastes Exposed to External Sulfate Attack by in situ X-ray Computed Tomography
1
作者 WU Min CAO Kailei +4 位作者 XIAO Weirong YU Zetai CAO Jierong DING Qingjun LI Jinhui 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2025年第1期164-170,共7页
The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an ... The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an X-ray computed tomography(X-ray CT)was used,i e,the tomography system of Zeiss Xradia 510 versa.The results indicate that X-CT can monitor the development process and distribution characteristics of the internal cracks of cement pastes under ESA with attack time.In addition,the C3A content in the cement significantly affects the damage mode of cement paste specimens during sulfate erosion.The damage of ordinary Portland cement(OPC)pastes subjected to sulfate attack with high C3A content are severe,while the damage of sulfate resistant Portland cement(SRPC)pastes is much smaller than that of OPC pastes.Furthermore,a quadratic function describes the correlation between the crack volume fraction and development depth for two cement pastes immermed in sulfate solution. 展开更多
关键词 CONCRETE external sulfate attack damage evolution situ x-ray computed tomography
原文传递
Analyzing structural changes induced by gas migration in heterogeneous pellet/powder bentonite mixtures through X-ray computed micro-tomography
2
作者 Mohammed Zaidi Nadia Mokni +1 位作者 Magdalena Dymitrowska Kui Liu 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第5期3198-3212,共15页
Understanding the mechanisms of gas transport and the resulting preferential pathways formation through bentonite-based barriers is essential for their performance evaluation.In this experimental study,gas migration w... Understanding the mechanisms of gas transport and the resulting preferential pathways formation through bentonite-based barriers is essential for their performance evaluation.In this experimental study,gas migration within a heterogenous mixture of MX80 bentonite pellets and powder with a ratio of 80/20 in dry mass was investigated.A novel X-ray transparent constant volume cell has been developed to assess the effect of gas pressure,material heterogeneities,and water vapor gas saturation on breakthrough pressure and gas pathways.The new cell allows to perform high-resolution X-ray computed micro-tomography(X-ray μCT)scans to track microstructural changes during different phases of saturation and gas injection.Experimental results showed that the gas breakthrough occurred when the pressure was raised to 3 MPa.This is slightly higher than the expected swelling pressure(2.9 MPa)of the bentonite sample.Each gas injection was followed by a long resaturation phase restoring material homogeneity at μCT resolution scale(16 mm).However,the elapsed time needed for gas to breakthrough at 3 MPa diminished at each subsequent injection test.X-ray μCT results also revealed the opening of the specimen/cell wall interface during gas passage.This opening expanded as the injection pressure increased.The gas flow along the interface was associated with the development of dilatant pathways inside the sample,although they did not reach the outlet surface.It was observed that the water vapor gas saturation had no effect on the breakthrough pressure.These findings enhance the understanding of the complex mechanisms underlying microstructural evolution and gas pathway development within the highly heterogeneous mixture.The experimental outcomes highlight the effectiveness of X-ray μCT to improve quality protocols for engineering design and safety assessments of engineered barriers. 展开更多
关键词 Bentonite pellet-powder mixture Gas migration Breakthrough pressure Gas pathways x-ray computed tomography Heterogenous bentonite mixture
在线阅读 下载PDF
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
3
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
在线阅读 下载PDF
Renal angiomyolipomas:Typical and atypical features on computed tomography and magnetic resonance imaging 被引量:1
4
作者 Andres Labra Giancarlo Schiappacasse +1 位作者 Diego Constenla Joaquin Cristi 《World Journal of Radiology》 2025年第2期11-20,共10页
Angiomyolipomas(AMLs)represent the most common benign solid renal tumors.The frequency of their detection in the general population is increasing owing to advances in imaging technology.The objective of this review is... Angiomyolipomas(AMLs)represent the most common benign solid renal tumors.The frequency of their detection in the general population is increasing owing to advances in imaging technology.The objective of this review is to discuss computed tomography(CT)and magnetic resonance imaging findings for both typical and atypical renal AMLs,along with their associated complications.AMLs are typically defined as solid triphasic tumors composed of varying amounts of dysmorphic and tortuous blood vessels,smooth muscle components and adipose tissue.In an adult,a classical renal AML appears as a solid,heterogeneous renal cortical mass with macroscopic fat.However,up to 5%of AMLs contain minimal fat and cannot be reliably diagnosed by imaging.Fat-poor AMLs can appear as hyperattenuating masses on unenhanced CT and as hypointense masses on T2WI;other AMLs may be isodense or exhibit cystic components.Hemorrhage is the most common complication,and AMLs with hemorrhage can mimic other tumors,making their diagnosis challenging.Understanding the variable and heterogeneous nature of this neoplasm to correctly classify renal AMLs and to avoid misdiagnosis of other renal lesions is crucial. 展开更多
关键词 Kidney neoplasms ANGIOMYOLIPOMA Classic angiomyolipoma-fat poor angiomyolipoma tomography x-ray computed Magnetic resonance imaging
暂未订购
Use of X-ray computed tomography to study structures and particle contacts of granite residual soil 被引量:19
5
作者 SUN Yin-lei TANG Lian-sheng 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第4期938-954,共17页
A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d... A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil. 展开更多
关键词 x-ray computed tomography granite residual soil RECONSTRUCTION REGULARIZATION particle contact
在线阅读 下载PDF
Effects of dry-wet cycles on three-dimensional pore structure and permeability characteristics of granite residual soil using X-ray micro computed tomography 被引量:26
6
作者 Ran An Lingwei Kong +1 位作者 Xianwei Zhang Chengsheng Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第3期851-860,共10页
Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive to... Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results. 展开更多
关键词 Granite residual soil Dry-wet cycle x-ray micro computed tomography(micro-CT) Three-dimensional(3D)pore distribution Seepage simulations PERMEABILITY
在线阅读 下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:9
7
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance.To quantify the mineral dissemination and pore space distribution of an ore particle,a... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance.To quantify the mineral dissemination and pore space distribution of an ore particle,a cylindrical copper oxide ore sample(I center dot 4.6 mm x 5.6 mm)was scanned using high-resolution X-ray computed tomography(HRXCT),a nondestructive imaging technology,at a spatial resolution of 4.85 mu m.Combined with three-dimensional(3D)image analysis techniques,the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated.In addition,the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques.Furthermore,the pore phase features,including the pore size distribution,pore surface area,pore fractal dimension,pore centerline,and the pore connectivity,were investigated quantitatively.The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated,with a large surface area and low connectivity.This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution x-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
在线阅读 下载PDF
Three-dimensional visualization and quantification of microporosity in aluminum castings by X-ray micro-computed tomography 被引量:5
8
作者 Cheng Gu Yan Lu Alan A.Luo 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2021年第6期99-107,共9页
Porosity is a major issue in solidification processing of metallic materials.In this work,wedge die casting experiments were designed to investigate the effect of cooling rate on microporosity in an aluminum alloy A35... Porosity is a major issue in solidification processing of metallic materials.In this work,wedge die casting experiments were designed to investigate the effect of cooling rate on microporosity in an aluminum alloy A356.Microstructure information including dendrites and porosity were measured and observed by optical microscopy and X-ray micro-computed tomography(XMCT).The effects of cooling rate on secondary dendrite arm spacing(SDAS)and porosity were discussed.The relationship between SDAS and cooling rate was established and validated using a mathematical model.Three-dimensional(3-D)porosity information,including porosity percentage,pore volume,and pore number,was determined by XMCT.With the cooling rate decreasing from a lower to a higher position of the wedge die,the observed pore number decreases,the porosity percentage increases,and the equivalent pore radius increases.Sphericity of the pores was discussed as an empirical criterion to distinguish the types of porosity.For different cooling rates,the larger the equivalent pore radius is,the lower the sphericity of the pores.This research suggests that XMCT is a useful tool to provide critical 3-D porosity information for integrated computational materials engineering(ICME)design and process optimization of solidification products. 展开更多
关键词 x-ray computed tomography Casting micropore Quantitative evaluation Al alloy
原文传递
Microstructure Evolution of Sandstone Cemented by Microbe Cement Using X-ray Computed Tomography 被引量:4
9
作者 RONG Hui QIAN Chunxiang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1134-1139,共6页
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica... The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone. 展开更多
关键词 microbe cement bio-sandstone microstructure evolution x-ray computed tomography CALCITE
原文传递
Review of X-ray and computed tomography scan findings with a promising role of point of care ultrasound in COVID-19 pandemic 被引量:5
10
作者 Darshan Gandhi Kriti Ahuja +4 位作者 Hemal Grover Pranav Sharma Shantanu Solanki Nishant Gupta Love Patel 《World Journal of Radiology》 CAS 2020年第9期195-203,共9页
As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not... As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not only helps assess the disease at the time of diagnosis but also aids evaluation of response to management,it is critical to examine the role of different modalities currently in use,such as baseline X-rays and computed tomography scans carefully.In this article,we will draw attention to the critical findings for the radiologist.Further,we will look at point of care ultrasound,an increasingly a popular tool in diagnostic medicine,as a component of COVID-19 management. 展开更多
关键词 x-ray computed tomography Point of care ultrasound COVID-19 CORONAVIRUS WUHAN
暂未订购
Isotropic compression behavior of granular assembly with non-spherical particles by X-ray micro-computed tomography and discrete element modeling 被引量:3
11
作者 Nan Zhang Ahmadreza Hedayat +4 位作者 Shaoyang Han Runlin Yang Héctor Gelber Bolaños Sosa Juan JoséGonzález Cárdenas Guido Edgard SalasÁlvarez 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2021年第5期972-984,共13页
The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.Howe... The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.However,limited studies on investigating the microscopic behavior of the granular assembly with real particle shapes under isotropic compression were reported.In this study,X-ray computed tomography(mCT)and discrete element modeling(DEM)were utilized to investigate isotropic compression behavior of the granular assembly with regard to the particle morphological properties,such as particle sphericity,concavity and interparticle frictions.The mCT was first used to extract the particle morphological parameters and then the DEM was utilized to numerically investigate the influences of the particle morphological properties on the isotropic compression behavior.The image reconstruction from mCT images indicated that the presented particle quantification algorithm was robust,and the presented microscopic analysis via the DEM simulation demonstrated that the particle surface concavity significantly affected the isotropic compression behavior.The observations of the particle connectivity and local void ratio distribution also provided insights into the granular assembly under isotropic compression.Results found that the particle concavity and interparticle friction influenced the most of the isotropic compression behavior of the granular assemblies. 展开更多
关键词 x-ray computed tomography(mCT) Discrete element modeling(DEM) Isotropic compression Particle surface curvature Particle morphology
在线阅读 下载PDF
Quantification of 3D macropore networks in forest soils in Touzhai valley(Yunnan,China)using X-ray computed tomography and image analysis 被引量:2
12
作者 ZHANG Jia-ming XU Ze-min +2 位作者 LI Feng HOU Ru-ji REN Zhe 《Journal of Mountain Science》 SCIE CSCD 2017年第3期474-491,共18页
The three dimensional (3D) geometry of soil macropores largely controls preferential flow, which is a significant infiltrating mechanism for rainfall in forest soils and affects slope stability. However, detailed st... The three dimensional (3D) geometry of soil macropores largely controls preferential flow, which is a significant infiltrating mechanism for rainfall in forest soils and affects slope stability. However, detailed studies on the 3D geometry of macropore networks in forest soils are rare. The intense rainfall-triggered potentially unstable slopes were threatening the villages at the downstream of Touzhai valley (Yunnan, China). We visualized and quantified the 3D macropore networks in undisturbed soil columns (Histosols) taken from a forest hillslope in Touzhai valley, and compared them with those in agricultural soils (corn and soybean in USA; barley, fodder beet and red fescue in Denmark) and grassland soils in USA. We took two large undisturbed soil columns (250 mm^25o mmxsoo mm), and scanned the soil columns at in-situ soil water content conditions using X-ray computed tomography at a voxel resolution of 0.945 × 0.945 × 1.500o mm^3. After reconstruction and visualization, we quantified the characteristics of macropore networks. In the studied forest soils, the main types of maeropores were root channels, inter-aggregate voids, maeropores without knowing origin, root-soil interfaee and stone-soil interface. While maeropore networks tend to be more eomplex, larger, deeper and longer. The forest soils have high maeroporosity, total maeropore wall area density, node density, and large maeropore volume, hydraulie radius, mean maeropore length, angle, and low tortuosity. The findings suggest that maeropore networks in the forest soils have high inter- connectivity, vertical continuity, linearity and less vertically oriented. 展开更多
关键词 Slope stability Touzhai valley Rainfall infiltration Forest soils x-ray computed tomography 3D macropore networks
原文传递
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
13
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
在线阅读 下载PDF
X-ray Computed Tomography Characterization of 3D Tufted Twill Textile Composite for Aerostructures 被引量:1
14
作者 A.Saboktakin M.Shahrouz +1 位作者 T.Vu-Khanh J.Bicerano 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期7-13,共7页
Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the f... Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the fracture behavior of 3D tufted textile composites.X-ray computed tomography as a non-destructive evaluation method is appropriate to detect damage locations and identify their progression in 3D textile composites.Destructive methods such as sectioning toward observing damage provide valuable information about damage patterns.The results of this research could be utilized to evaluate the initial cause of rupture in 3D tufted composites used in aerospace structures and analyze fracture modes and damage progression. 展开更多
关键词 x-ray computed tomography DAMAGE CHARACTERIZATION 3D composite TEXTILE PREFORM
在线阅读 下载PDF
Using X-ray computed tomography and micro-Raman spectrometry to measure individual particle surface area, volume, and morphology towards investigating atmospheric heterogeneous reactions 被引量:1
15
作者 Mingjin Wang Nan Zheng +6 位作者 Tong Zhu Jing Shang Ting Yu Xiaojuan Song Defeng Zhao Yong Guan Yangchao Tian 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第7期23-32,共10页
Heterogeneous reactions on the aerosol particle surface in the atmosphere play important roles in air pollution, climate change, and global biogeochemical cycles. However, the reported uptake coefficients of heterogen... Heterogeneous reactions on the aerosol particle surface in the atmosphere play important roles in air pollution, climate change, and global biogeochemical cycles. However, the reported uptake coefficients of heterogeneous reactions usually have large variations and may not be relevant to real atmospheric conditions. One of the major reasons for this is the use of bulk samples in laboratory experiments, while particles in the atmosphere are suspended individually. A number of technologies have been developed recently to study heterogeneous reactions on the surfaces of individual particles. Precise measurements on the reactive surface area, volume, and morphology of individual particles are necessary for calculating the uptake coefficient, quantifying reactants and products, and understanding the reaction mechanism better. In this study, for the first time we used synchrotron radiation X-ray computed tomography(XCT) and micro-Raman spectrometry to measure individual CaCO_3 particle morphology, with sizes ranging from 3.5–6.5 μm. Particle surface area and volume were calculated using a reconstruction method based on software threedimensional(3-D) rendering. The XCT was first validated with high-resolution fieldemission scanning electron microscopy(FE-SEM) to acquire accurate CaCO_3 particle surface area and volume estimates. Our results showed an average difference of only 6.1% in surface area and 3.2% in volume measured either by micro-Raman spectrometry or X-ray tomography. X-ray tomography and FE-SEM can provide more morphological details of individual Ca CO3 particles than micro-Raman spectrometry. This study demonstrated that X-ray computed tomography and micro-Raman spectrometry can precisely measure the surface area, volume, and morphology of an individual particle. 展开更多
关键词 Heterogeneous reactions Individual CaCO3 particle Micro-Raman spectrometry Synchrotron radiation x-ray computed tomography MORPHOLOGY Surface area VOLUME
原文传递
Seeing through Materials:X-Ray Imaging Using Computed Tomography 被引量:1
16
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(XCT) SYNCHROTRON DENDRITE POROSITY ALLOYS
在线阅读 下载PDF
Performance evaluation of the simpli¯ed spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging 被引量:1
17
作者 Haibo Zhang Guohua Geng +6 位作者 Yanrong Chen Fengjun Zhao Yuqing Hou Huangjian Yi Shunli Zhang Jingjing Yu Xiaowei He 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第3期97-106,共10页
As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)dis... As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)distribution of the probes from surface measurements.A proper photon-transportation model is critical to accuracy of XLCT.Here,we presented a systematic comparison between the common-used Monte Carlo model and simplified spherical harmonics(SPN).The performance of the two methods was evaluated over several main spec-trums using a known XLCT material.We designed both a global measurement based on the cosine similarity and a locally-averaged relative error,to quantitatively assess these methods.The results show that the SP_(3) could reach a good balance between the modeling accuracy and computational efficiency for all of the tested emission spectrums.Besides,the SP_(1)(which is equivalent to the difusion equation(DE))can be a reasonable alternative model for emission wavelength over 692nm.In vivo experiment further demonstrates the reconstruction perfor-mance of the SP:and DE.This study would provide a valuable guidance for modeling the photon-transportation in CB-XLCT. 展开更多
关键词 Cone-beam x-ray luminescence computed tomography photon-transportation model .simplified spherical harmonics approximation diffusion equations.
原文传递
X-Ray Computed Tomography for Root Quantification 被引量:1
18
作者 Bente Foereid 《Open Journal of Soil Science》 2015年第7期145-148,共4页
Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and we... Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and weight and length were determined by conventional means. Root volume and surface area were then calculated from the 3D images using state of the art software and methodology, and the measured and calculated measures were correlated. The only strong and significant correlation was between measured weight and calculated volume for mutants without root hairs. It is concluded that the software cannot segment out very small roots, but segmentation accuracy also depends on root structure in some unknown way. Any study using X-ray computed tomography to quantify roots as they grow in situ should start with a calibration for the conditions in question. 展开更多
关键词 ROOTS 3D IMAGE x-ray computed tomography
暂未订购
Distinct root system acclimation patterns of seagrass Zostera japonica in sediments of different trophic status:a research by X-ray computed tomography
19
作者 Xiaoyue SONG Yi ZHOU +7 位作者 Jiangning ZENG Lu SHOU Xiaomei ZHANG Shidong YUE Wei GAO Weihua FENG Zhifu WANG Ping DU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2021年第6期2267-2280,共14页
Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collec... Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collected from typical oligotrophic and eutrophic sediments in two coastal sites of northern China,and determined sediment physicochemical properties that might influence root system morphology,density,and distribution.The trophic status of sediments had little influence on the Z.japonica root length,and diameters of root and rhizome.However,Z.japonica in oligotrophic sediment developed the root system with longer rhizome node,deeper rhizome distribution,and larger allocation to below-ground tissues in order to acquire more nutrients and relieve the N deficiency.And the lower root and rhizome densities of Z.japonica in eutrophic sediment were mainly caused by fewer shoots and shorter longevity,which was resulted from the more serious sulfide inhibition.Our results systematically revealed the effect of sediment trophic status on the phenotypic plasticity,quantity,and distribution of Z.japonica root system,and demonstrated the feasibly of X-ray CT in seagrass root system research. 展开更多
关键词 Zostera japonica root system acclimation pattern SEDIMENT trophic status x-ray computed tomography
在线阅读 下载PDF
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
20
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor x-ray computed tomography(CT)
在线阅读 下载PDF
上一页 1 2 29 下一页 到第
使用帮助 返回顶部