Based on a digital image correlation(DIC)method with the measurements of a high speed crack's displacement and strain fields,a technique to accurately and automatically locate its crack tip has been developed.The c...Based on a digital image correlation(DIC)method with the measurements of a high speed crack's displacement and strain fields,a technique to accurately and automatically locate its crack tip has been developed.The crack tip is identified by finding the abrupt jump on the opening(or dislocation)curve of a point on the trace of the crack propagation,while the opening is measured through a virtual extensometer technique and the abrupt jump is identified by finding the peak on the curve.The method was verified using a specially designed experiment and applied to measure the critical crack tip opening angle of a rock sample.Because the involvement of analytical models has been avoided and then the good performance could be ensured for low resolution speckle images,this technique is expected to be very useful in the quantitative study of high speed cracks in experiments using high speed cameras.展开更多
Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This wo...Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data. Methods: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle. Results: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar. Conclusion: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively.展开更多
基金Supported by the National Natural Science Foundation of China(11172039,11402023)the Fundamental Research Funding of BIT(20120142021)the State Key Laboratory of Earthquake Dynamics(LED2011B03)
文摘Based on a digital image correlation(DIC)method with the measurements of a high speed crack's displacement and strain fields,a technique to accurately and automatically locate its crack tip has been developed.The crack tip is identified by finding the abrupt jump on the opening(or dislocation)curve of a point on the trace of the crack propagation,while the opening is measured through a virtual extensometer technique and the abrupt jump is identified by finding the peak on the curve.The method was verified using a specially designed experiment and applied to measure the critical crack tip opening angle of a rock sample.Because the involvement of analytical models has been avoided and then the good performance could be ensured for low resolution speckle images,this technique is expected to be very useful in the quantitative study of high speed cracks in experiments using high speed cameras.
基金the Science Research Foundation of Ministry of Health of China (No. WKJ2006-2-003)the Department of Education of Zhejiang Province (No. 20010505) the Science and Technol-ogy Department of Zhejiang Province (No. 2003C30044), China
文摘Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data. Methods: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle. Results: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar. Conclusion: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively.