期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Optimizing neon-based gas mixtures for two-stage amplification fast-timing Micromegas detectors
1
作者 Yue Meng Xu Wang +3 位作者 Jianbei Liu Ming Shao Zhiyong Zhang Yi Zhou 《中国科学技术大学学报》 北大核心 2025年第4期59-66,58,I0002,共10页
The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process th... The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance. 展开更多
关键词 gaseous detectors MICROMEGAS timing detectors fast-timing Micromegas Monte Carlo simulation gain uniformity
在线阅读 下载PDF
Measurement of X-ray photon energy and arrival time using a silicon drift detector 被引量:1
2
作者 刘利 郁海 郑伟 《Chinese Physics C》 SCIE CAS CSCD 2014年第3期39-44,共6页
Detecting the X-ray emission of pulsars and obtaining the photons' time of arrival are the foundational steps in autonomous navigation via X-ray pulsar measurement.The precision of a pulse's time of arrival is mainl... Detecting the X-ray emission of pulsars and obtaining the photons' time of arrival are the foundational steps in autonomous navigation via X-ray pulsar measurement.The precision of a pulse's time of arrival is mainly determined by the precision of photon arrival time measurement.In this work,a silicon drift detector is used to measure photon energy and arrival time.The measurement system consists of a signal detector,a processing unit,a signal acquisition unit and a data receiving unit.This system acquires the energy resolution and arrival time information of photons.In particular,background noise with different energies disturbs pulse profile forming,the system can also achieve a high signal-to-noise ratio profile.Ground test results show that this system can be applied in autonomous navigation based on X-ray pulsar measurement. 展开更多
关键词 X-ray photon energy time of arrival detector
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部