In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator a...In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation.展开更多
This paper describes the design and development of the timer based on liquid level measurement system in which timer 555 is used in astable mode. The capacitor charging time i. e. the ON time pulse width of the ti...This paper describes the design and development of the timer based on liquid level measurement system in which timer 555 is used in astable mode. The capacitor charging time i. e. the ON time pulse width of the timer output waveform which is measured using a digital storage oscillator (DSO),is linearly proportional to the capacitance of a co-axial cylindrical capacitive transducer, and this capacitance once again linearly varies with the change in liquid level. Hence, we obtain a linear relationship between the liquid level and the capacitor charging time. The main advantages of this developed system are linear input-output relationship, small in size, easily portable, cost effective, and independent on the ambient temperature effect. The system can also be exploited to measure dielectric constant of liquid or solid in various process industries.展开更多
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra...Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.展开更多
随着分子生物学技术蓬勃发展,越来越多的肿瘤学者通过The Cancer Genome Atlas(TCGA)数据库下载高通量测序数据,运用生物信息学分析的方法,识别肿瘤免疫微环境中各种细胞的表达量,进行肿瘤浸润性免疫细胞的分析工作,但是肿瘤与免疫的相...随着分子生物学技术蓬勃发展,越来越多的肿瘤学者通过The Cancer Genome Atlas(TCGA)数据库下载高通量测序数据,运用生物信息学分析的方法,识别肿瘤免疫微环境中各种细胞的表达量,进行肿瘤浸润性免疫细胞的分析工作,但是肿瘤与免疫的相互作用往往十分复杂,临床工作人员面对庞大数据量展开分析工作仍然充满困难,基于此本文介绍一款全面分析肿瘤浸润性免疫细胞及其可视化的数据库TIMER2.0,旨在为临床研究人员轻松识别多种癌症类型与正常组织及免疫细胞浸润之间的基因组学关系,快速运用多种算法掌握肿瘤概况。展开更多
文摘In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation.
文摘This paper describes the design and development of the timer based on liquid level measurement system in which timer 555 is used in astable mode. The capacitor charging time i. e. the ON time pulse width of the timer output waveform which is measured using a digital storage oscillator (DSO),is linearly proportional to the capacitance of a co-axial cylindrical capacitive transducer, and this capacitance once again linearly varies with the change in liquid level. Hence, we obtain a linear relationship between the liquid level and the capacitor charging time. The main advantages of this developed system are linear input-output relationship, small in size, easily portable, cost effective, and independent on the ambient temperature effect. The system can also be exploited to measure dielectric constant of liquid or solid in various process industries.
文摘Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.
文摘随着分子生物学技术蓬勃发展,越来越多的肿瘤学者通过The Cancer Genome Atlas(TCGA)数据库下载高通量测序数据,运用生物信息学分析的方法,识别肿瘤免疫微环境中各种细胞的表达量,进行肿瘤浸润性免疫细胞的分析工作,但是肿瘤与免疫的相互作用往往十分复杂,临床工作人员面对庞大数据量展开分析工作仍然充满困难,基于此本文介绍一款全面分析肿瘤浸润性免疫细胞及其可视化的数据库TIMER2.0,旨在为临床研究人员轻松识别多种癌症类型与正常组织及免疫细胞浸润之间的基因组学关系,快速运用多种算法掌握肿瘤概况。