Cases of widespread bone hydatid infection are relatively rare in clinical practice.In this study,we reported for the first time a validated integrated repair therapy for multiple bone tissues,including the hip,femur,...Cases of widespread bone hydatid infection are relatively rare in clinical practice.In this study,we reported for the first time a validated integrated repair therapy for multiple bone tissues,including the hip,femur,and knee,caused by echinococ cosis.Artificial intelligence(AI)was used to develop a targeted surgical plan and to design a personalized prosthesis.Finite element analysis(FEA)was used to optimize the mechanical effectiveness of a customized integrated replacement prosthesis and to model stress distribution in the surrounding bone.Three-dimensional(3 D)printing was used to fabricate a customized prosthesis.With the assistance of AI,FEA,and 3 D printing technology,a personalized surgical plan and customized prosthesis were successfully constructed based on the patient’s disease.This approach achieved a successful therapeutic effect,demonstrating that AI-assisted personalized medicine holds great promise for the future.展开更多
BACKGROUND Giant cell tumors(GCT)are most commonly seen in the distal femur.These tumors are uncommon in the small bones of the hand and feet,and a very few cases have been reported.A giant cell tumor of the talus is ...BACKGROUND Giant cell tumors(GCT)are most commonly seen in the distal femur.These tumors are uncommon in the small bones of the hand and feet,and a very few cases have been reported.A giant cell tumor of the talus is rarely seen clinically and could be a challenge to physicians.CASE SUMMARY We report a rare case of GCT of the talus in one patient who underwent a new reconstructive surgery technique using a three-dimensional(3D)printing talar prosthesis.The prosthesis shape was designed by tomographic image processing and segmentation using technology to match the intact side by mirror symmetry with 3D post-processing technologies.The patient recovered nearly full range of motion of the ankle after 6 mo.The visual analogue scale and American Orthopaedic Foot and Ankle Society scores were 1 and 89 points,respectively.CONCLUSION We demonstrated that 3D printing of a talar prosthesis is a beneficial option for GCT of the talus.展开更多
Internal structural defects in engineering rock masses vary in size,exhibit complex shapes,and are unevenly distributed.Dominant fractures within a rock mass often play a critical to its mechanical behavior,directly a...Internal structural defects in engineering rock masses vary in size,exhibit complex shapes,and are unevenly distributed.Dominant fractures within a rock mass often play a critical to its mechanical behavior,directly affecting the macromechanical properties and failure modes.These fractures affect the instability and failure of the surrounding rock,significantlyimpacting the overall stability of engineering structures.Herein,sand-powder three-dimensional(3D)printing technology was used to prepare rock-like specimens with internal fracture networks.Triaxial compression testing,post-failure fracture mapping,and fractal dimension analysis of the fracture surfaces were conducted to investigate the effects of dominant fracture angles on the strength and deformation of rocks with internal fracture networks under triaxial stress.The results indicate that the dominant fracture angle has a pronounced effect on the mechanical behavior of rock.With increasing angle,both compressive strength and elastic modulus exhibit an initial decline followed by an increase.Moreover,higher confiningpressure significantlyimproves the compressive strength of fractured rock.This enhancement weakens as the confiningpressure further increases.Moreover,with increasing confiningpressure,the differences between the maximum and minimum values of elastic moduli and lateral strain ratios in fractured rock gradually decrease.Thus,the impact of the dominant fracture angle on rock mass deformation decreases with increasing confiningpressure.This research elucidates the effects of dominant fracture angles on the mechanical and failure properties of complex fractured rock masses and the influenceof the confiningpressure on these relationships.It provides valuable theoretical insights and practical guidance for stability analyses in engineering rock masses.展开更多
BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular compon...BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning.展开更多
Background: As the population age structure gradually ages, more and more elderly people were found to have pulmonary nodules during physical examinations. Most elderly people had underlying diseases such as heart, lu...Background: As the population age structure gradually ages, more and more elderly people were found to have pulmonary nodules during physical examinations. Most elderly people had underlying diseases such as heart, lung, brain and blood vessels and cannot tolerate surgery. Computed tomography (CT)-guided percutaneous core needle biopsy (CNB) was the first choice for pathological diagnosis and subsequent targeted drugs, immune drugs or ablation treatment. CT-guided percutaneous CNB requires clinicians with rich CNB experience to ensure high CNB accuracy, but it was easy to cause complications such as pneumothorax and hemorrhage. Three-dimensional (3D) printing coplanar template (PCT) combined with CT-guided percutaneous pulmonary CNB biopsy has been used in clinical practice, but there was no prospective, randomized controlled study. Methods: Elderly patients with lung nodules admitted to the Department of Oncology of our hospital from January 2019 to January 2023 were selected. A total of 225 elderly patients were screened, and 30 patients were included after screening. They were randomly divided into experimental group (Group A: 30 cases) and control group (Group B: 30 cases). Group A was given 3D-PCT combined with CT-guided percutaneous pulmonary CNB biopsy, Group B underwent CT-guided percutaneous pulmonary CNB. The primary outcome measure of this study was the accuracy of diagnostic CNB, and the secondary outcome measures were CNB time, number of CNB needles, number of pathological tissues and complications. Results: The diagnostic accuracy of group A and group B was 96.67% and 76.67%, respectively (P = 0.026). There were statistical differences between group A and group B in average CNB time (P = 0.001), number of CNB (1 vs more than 1, P = 0.029), and pathological tissue obtained by CNB (3 vs 1, P = 0.040). There was no statistical difference in the incidence of pneumothorax and hemorrhage between the two groups (P > 0.05). Conclusions: 3D-PCT combined with CT-guided percutaneous CNB can improve the puncture accuracy of elderly patients, shorten the puncture time, reduce the number of punctures, and increase the amount of puncture pathological tissue, without increasing pneumothorax and hemorrhage complications. We look forward to verifying this in a phase III randomized controlled clinical study. .展开更多
The intricate anatomy of the corpus cavernosum in both the flaccid and tumescent state has not been fully elucidated. We report our experience using a three-dimensional (3D) scanner to reconstruct cadaveric casts an...The intricate anatomy of the corpus cavernosum in both the flaccid and tumescent state has not been fully elucidated. We report our experience using a three-dimensional (3D) scanner to reconstruct cadaveric casts and compare them with 3D images of two prototypes of penile prosthesis. Two different models of the Titan Coloplast inflatable penile prosthesis were analyzed using a 3D scanner. The first was the standard model and the second was a newer model with a rounder silicone tip. Two cadaveric phalluses were harvested using Smooth-Cast 300Q polyurethane molding. The molds were excised and scanned along side the penile prosthesis. 3D scans were completed and analyzed using Leios Mesh software, and GOM Inspect software. The 3D scans demonstrated the mean human corporal radii 2 mm from the distal tip to be 36.51 mm (36.01-37.0 mm), which is an obtuse angle. The standard Titan penile prosthesis spherical radius at the same level was 202.52 mm, while the new silicone tip prosthesis had a radius of 139.33 mm. 3D mapping further demonstrated the trajectory of the cavernosa appeared curvilinear and the distal ends appeared blunt. The use of cadaveric cavernosal molds in combination with the 3D scanner allowed us to accurately image the corpus cavernosum for the first time. Our findings suggest that anatomically accurate corporal tips appear to be relatively blunt and that the new Titan silicone tip penile prosthesis more closely resembles the human corporal tip.展开更多
This study investigated the resilience of traditional concrete dams compared to 3D printed concrete dams(3DPC)when subjected to debris flow.Three types of dams,namely check dams,arch dams,and curve dams,were numerical...This study investigated the resilience of traditional concrete dams compared to 3D printed concrete dams(3DPC)when subjected to debris flow.Three types of dams,namely check dams,arch dams,and curve dams,were numerically analyzed using a three-dimensional Coupled Eulerian-Lagrangian(CEL)methodology.The research focused on critical factors such as impact force and viscous energy dissipation to compare dam performance.Additionally,the study examined the printing and service phases of 3DPC models,determining potential failure modes and analyzing printing parameters.The results demonstrated that 3DPC dams outperformed traditional concrete dams,with filament deposition orientation,perpendicular to the debris flow direction,identified as a pivotal factor.Infill percentage and pattern were also found to influence the behavior of 3DPC models.Notably,curved dams exhibited superior performance based on dam geometry.These findings have significant potential for advancing the development of resilient dam structures capable of withstanding debris flow impacts.展开更多
Based on the building principle of additive manufacturing,printing orientation mainly determines the tribological properties of joint prostheses.In this study,we created a polyether-ether-ketone(PEEK)joint prosthesis ...Based on the building principle of additive manufacturing,printing orientation mainly determines the tribological properties of joint prostheses.In this study,we created a polyether-ether-ketone(PEEK)joint prosthesis using fused filament fabrication and investigated the effects of printing orientation on its tribological properties using a pin-on-plate tribometer in 25% newborn calf serum.An ultrahigh molecular weight polyethylene transfer film is formed on the surface of PEEK due to the mechanical capture of wear debris by the 3D-printed groove morphology,which is significantly impacted by the printing orientation of PEEK.When the printing orientation was parallel to the sliding direction of friction,the number and size of the transfer film increased due to higher steady stress.This transfer film protected the matrix and reduced the friction coefficient and wear rate of friction pairs by 39.13%and 74.33%,respectively.Furthermore,our findings provide a novel perspective regarding the role of printing orientation in designing knee prostheses,facilitating its practical applications.展开更多
The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who...The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology)by one surgeon at a single hospital were studied.The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule.Data collected included the operative duration,the blood loss,the damage of the important tissue,the biographic union and therecovery of the function after the operation.Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits.The scores of reduction and function were measured during follow-up.Results showed that the wounds of 30 patients were healed in the first stage,and there was no injury of important structures such as blood vessels and nerves.According to the Matta criteria,excellent effectiveness was obtained in 22 cases and good in 8 cases.According to the functional evaluation criteria of Majeed,excellent effectiveness was obtained in 21 cases and good in 9 cases.It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation,which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved,and better surgical result was finally achieved.展开更多
The increasing demand for geometrically complex structures—specifically, higher-inlet-temperature turbine blades for the fifth-generation or other high-generation machines of advanced fighter aircrafts—hasmade the d...The increasing demand for geometrically complex structures—specifically, higher-inlet-temperature turbine blades for the fifth-generation or other high-generation machines of advanced fighter aircrafts—hasmade the development of more complex double-walled three-layer hollow-cavity structures a necessity.However, this requires the preparation of complex ceramic cores and advanced, integrated technologies.Stereolithographic three-dimensional printing (SLA-3DP) technology, with digital control upon materialmorphology, composition, and structure, is a high integration and versatile technique that is superior tothe traditional manufacturing techniques for ceramic cores, including gel casting, injection molding, andhot pressing. The latent capacity of this technique is contingent on the progress of processing routesthat significantly reduce the distortion and defect formation in response to the elimination of the reactedorganic monomer phase during photo-curing. Despite the tremendous progress in the field, multiple challenges remain, such as the preparation of high-solid-content and low-viscosity suspensions, SLA-3DP oflarge double-walled ceramic cores with complex structures, and process optimization and sinter strengthening for the fabrication of ceramic cores. These challenges have prevented the broader applications andreduced the impact of the SLA-3DP technology. This review discusses cutting-edge research on the crucialfactors governing this production method. Specifically, we outline the existing challenges within the fieldand provide our perspective on the upcoming research work and progress.展开更多
BACKGROUND With the increasing complexity of surgical interventions performed in orthopaedic trauma surgery and the improving technologies used in threedimensional(3D)printing,there has been an increased interest in t...BACKGROUND With the increasing complexity of surgical interventions performed in orthopaedic trauma surgery and the improving technologies used in threedimensional(3D)printing,there has been an increased interest in the concept.It has been shown that 3D models allow surgeons to better visualise anatomy,aid in planning and performing complex surgery.It is however not clear how best to utilise the technique and whether this results in better outcomes.AIM To evaluate the effect of 3D printing used in pre-operative planning in orthopaedic trauma surgery on clinical outcomes.METHODS We performed a comprehensive systematic review of the literature and a metaanalysis.Medline,Ovid and Embase were searched from inception to February 8,2018.Randomised controlled trials,case-control studies,cohort studies and case series of five patients or more were included across any area of orthopaedic trauma.The primary outcomes were operation time,intra-operative blood loss and fluoroscopy used.RESULTS Seventeen studies(922 patients)met our inclusion criteria and were reviewed.The use of 3D printing across all specialties in orthopaedic trauma surgery demonstrated an overall reduction in operation time of 19.85%[95%confidence intervals(CI):(-22.99,-16.71)],intra-operative blood loss of 25.73%[95%CI:(-31.07,-20.40)],and number of times fluoroscopy was used by 23.80%[95%CI:(-38.49,-9.10)].CONCLUSION Our results suggest that the use of 3D printing in pre-operative planning in orthopaedic trauma reduces operative time,intraoperative blood loss and the number of times fluoroscopy is used.展开更多
This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to De...This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to December 2016),in which the guiding template printed by the three-dimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis,was performed.Totally,4 males and 3 females were included in template group,aged from 38to 65years old (mean 50.86±8.90).Of them,5 had sacral fractures (3 with Denis type Ⅰ and 2 with type Ⅱ)and 2 the separation of sacroiliac joint.Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out.A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively.The time of each screw insertion,volume of intra-operative blood loss,and the exposure to X ray were analyzed and the Matta's radiological criteria were used to evaluate the reduction quality.The Majeed score was used to evaluate postoperative living quality.The visual analogue scale (VAS)was applied at different time points to judge pain relief of coccydynia.All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months,mean (16.57±2.44)months.Totally 9 sacroiliac screws for the S 1 and S2 vertebra were inserted in the 7 patients.The time length for each screw insertion ranged from 450 to 870 s,mean (690.56±135.68)s,and the number of times of exposure to X ray were 4 to 8,mean (5.78±1.20).The intra-operative blood loss ranged from 45to 120 mL,mean (75±23.32)mL.According to Matta's radiology criteria,the fracture and dislocation reduction were excellent in 6cases and good in 1.The pre-operative VAS score ranged from 5.2 to 8.1,mean (7.13±1.00).The average one-week/six-month post-operative VAS was (5.33±0.78)and (1.33±0.66),respectively (P<0.05 when compared with pre-operative VAS).The 12-month post-operative Majeed score ranged from 86 to 92,mean (90.29±2.21).The three-dimensional printed guiding template for sacroiliac screw insertion,which could significantly shorten the operation time,provide a satisfied outcome of the stabilization of the pelvic ring,and protect doctors and patients from X-ray exposure,might be a practical and valuable new clinical technique.展开更多
As an emerging technology to promote the combination of medicine and industry,the three-dimensional(3D)printing has developed rapidly in the fields of orthopedics,while its unique advantages in improving precise treat...As an emerging technology to promote the combination of medicine and industry,the three-dimensional(3D)printing has developed rapidly in the fields of orthopedics,while its unique advantages in improving precise treatment still need to be further popularized.In this report,our team have exhibited several classic cases of integrating 3D printing into orthopedic clinical application,thereby further elaborating thoughts and opinions on the significance of 3D printing in the orthopedic clinical application,technical advantages,existing main problems and coping strategies.展开更多
Heart diseases remain the top threat to human health,and the treatment of heart diseases changes with each passing day.Convincing evidence shows that three-dimensional(3D)printing allows for a more precise understandi...Heart diseases remain the top threat to human health,and the treatment of heart diseases changes with each passing day.Convincing evidence shows that three-dimensional(3D)printing allows for a more precise understanding of the complex anatomy associated with various heart diseases.In addition,3D-printed models of cardiac diseases may serve as effective educational tools and for hands-on simulation of surgical interventions.We introduce examples of the clinical applications of different types of 3D printing based on specific cases and clinical application scenarios of 3D printing in treating heart diseases.We also discuss the limitations and clinically unmet needs of 3D printing in this context.展开更多
Hepatocellular carcinoma(HCC)constitutes the fifth most frequent malignancy worldwide and the third most frequent cause of cancer-related deaths.Currently,treatment selection is based on the stage of the disease.Emerg...Hepatocellular carcinoma(HCC)constitutes the fifth most frequent malignancy worldwide and the third most frequent cause of cancer-related deaths.Currently,treatment selection is based on the stage of the disease.Emerging fields such as three-dimensional(3D)printing,3D bioprinting,artificial intelligence(AI),and machine learning(ML)could lead to evidence-based,individualized management of HCC.In this review,we comprehensively report the current applications of 3D printing,3D bioprinting,and AI/ML-based models in HCC management;we outline the significant challenges to the broad use of these novel technologies in the clinical setting with the goal of identifying means to overcome them,and finally,we discuss the opportunities that arise from these applications.Notably,regarding 3D printing and bioprinting-related challenges,we elaborate on cost and cost-effectiveness,cell sourcing,cell viability,safety,accessibility,regulation,and legal and ethical concerns.Similarly,regarding AI/ML-related challenges,we elaborate on intellectual property,liability,intrinsic biases,data protection,cybersecurity,ethical challenges,and transparency.Our findings show that AI and 3D printing applications in HCC management and healthcare,in general,are steadily expanding;thus,these technologies will be integrated into the clinical setting sooner or later.Therefore,we believe that physicians need to become familiar with these technologies and prepare to engage with them constructively.展开更多
Three-dimensional printing(3DP)offers valuable insight into the characterization of natural rocks and the verification of theoretical models due to its high reproducibility and accurate replication of complex defects ...Three-dimensional printing(3DP)offers valuable insight into the characterization of natural rocks and the verification of theoretical models due to its high reproducibility and accurate replication of complex defects such as cracks and pores.In this study,3DP gypsum samples with different printing directions were subjected to a series of uniaxial compression tests with in situ micro-computed tomography(micro-CT)scanning to quantitatively investigate their mechanical anisotropic properties and damage evolution characteristics.Based on the two-dimensional(2D)CT images obtained at different scanning steps,a novel void ratio variable was derived using the mean value and variance of CT intensity.Additionally,a constitutive model was formulated incorporating the proposed damage variable,utilizing the void ratio variable.The crack evolution and crack morphology of 3DP gypsum samples were obtained and analyzed using the 3D models reconstructed from the CT images.The results indicate that 3DP gypsum samples exhibit mechanical anisotropic characteristics similar to those found in naturally sedimentary rocks.The mechanical anisotropy is attributed to the bedding planes formed between adjacent layers and pillar-like structures along the printing direction formed by CaSO_(4)·2H_(2)O crystals of needle-like morphology.The mean gray intensity of the voids has a positive linear relationship with the threshold value,while the CT variance and void ratio have concave and convex relationships,respectively.The constitutive model can effectively match the stress–strain curves obtained from uniaxial compression experiments.This study provides comprehensive explanations of the failure modes and anisotropic mechanisms of 3DP gypsum samples,which is important for characterizing and understanding the failure mechanism and microstructural evolution of 3DP rocks when modeling natural rock behavior.展开更多
Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to crea...Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to create customized scaffolds with high precision and accuracy. In this study, an electrically controlled cortical impactor was used to induce randomized brain tissue defects. The overall shape of scaffolds was designed using rat-specific anatomical data obtained from magnetic resonance imaging, and the internal structure was created by computer- aided design. As the result of limitations arising from insufficient resolution of the manufacturing process, we magnified the size of the cavity model prototype five-fold to successfully fabricate customized collagen-chitosan scaffolds using three-dimensional printing. Results demonstrated that scaffolds have three-dimensional porous structures, high porosity, highly specific surface areas, pore connectivity and good internal characteristics. Neural stem cells co-cultured with scaffolds showed good viability, indicating good biocompatibility and biodegradability. This technique may be a promising new strategy for regenerating complex damaged brain tissues, and helps pave the way toward personalized medicine.展开更多
BACKGROUND Prior studies have shown that preserving the left colic artery(LCA)during laparo-scopic radical resection for rectal cancer(RC)can reduce the occurrence of anasto-motic leakage(AL),without compromising onco...BACKGROUND Prior studies have shown that preserving the left colic artery(LCA)during laparo-scopic radical resection for rectal cancer(RC)can reduce the occurrence of anasto-motic leakage(AL),without compromising oncological outcomes.However,anatomical variations in the branches of the inferior mesenteric artery(IMA)and LCA present significant surgical challenges.In this study,we present our novel three dimensional(3D)printed IMA model designed to facilitate preoperative rehearsal and intraoperative navigation to analyze its impact on surgical safety.AIM To investigate the effect of 3D IMA models on preserving the LCA during RC surgery.METHODS We retrospectively collected clinical dates from patients with RC who underwent laparoscopic radical resection from January 2022 to May 2024 at Fuyang People’s Hospital.Patients were divided into the 3D printing and control groups for sta-tistical analysis of perioperative characteristics.RESULTS The 3D printing observation group comprised of 72 patients,while the control group comprised 68 patients.The operation time(174.5±38.2 minutes vs 198.5±49.6 minutes,P=0.002),intraoperative blood loss(43.9±31.3 mL vs 58.2±30.8 mL,P=0.005),duration of hospitalization(13.1±3.1 days vs 15.9±5.6 days,P<0.001),postoperative recovery time(8.6±2.6 days vs 10.5±4.9 days,P=0.007),and the postoperative complication rate(P<0.05)were all significantly lower in the observation group.CONCLUSION Utilization of a 3D-printed IMA model in laparoscopic radical resection of RC can assist surgeons in understanding the LCA anatomy preoperatively,thereby reducing intraoperative bleeding and shortening operating time,demonstrating better clinical application potential.展开更多
A new type of implantable drug delivery devices ( DDD ) with complicated architectures were fubricated by three-dimensional printing technique, employing levofloxacin (LVFX) as a model drug. Processing parameters...A new type of implantable drug delivery devices ( DDD ) with complicated architectures were fubricated by three-dimensional printing technique, employing levofloxacin (LVFX) as a model drug. Processing parameters were optimized in riew of the layer thickness, spucing between printed lines, flow rate of liquid binder and the fast axis speed. The prepared DDD prototype consists of a double-layer structure, of which the upper region is a reservoir system and the lower region is a matrix one. The in vitro release test revealed that LVFX was released in a dual-puse pattern. This DDD may present a new strategy for the prophylaxis and treatment of diseases such as bone infection in the near future.展开更多
基金partially supported by the National Natural Science Foundation of China(Nos.32471474 and 82102574)the Precision Medicine Project of People’s Hospital of Xinjiang Uygur Autonomous Region(No.20220305)+4 种基金Chengdu Advanced Metal Materials Industry Technology Research Institute Co.,Ltd.Support Project(No.24H0802)Sichuan Science and Technology Program(Nos.2025YFHZ0086,2023YFS0053,2024YFHZ0125,and 2025ZNSFSC0381)Project of Tianfu Jincheng Laboratory(No.2025ZH009)Guangdong Basic and Applied Basic Research Foundation(No.2023A1515220102)Xinjiang Autonomous Region Science and Technology Support Project Plan(Directive)Project(No.2024E02049)。
文摘Cases of widespread bone hydatid infection are relatively rare in clinical practice.In this study,we reported for the first time a validated integrated repair therapy for multiple bone tissues,including the hip,femur,and knee,caused by echinococ cosis.Artificial intelligence(AI)was used to develop a targeted surgical plan and to design a personalized prosthesis.Finite element analysis(FEA)was used to optimize the mechanical effectiveness of a customized integrated replacement prosthesis and to model stress distribution in the surrounding bone.Three-dimensional(3 D)printing was used to fabricate a customized prosthesis.With the assistance of AI,FEA,and 3 D printing technology,a personalized surgical plan and customized prosthesis were successfully constructed based on the patient’s disease.This approach achieved a successful therapeutic effect,demonstrating that AI-assisted personalized medicine holds great promise for the future.
文摘BACKGROUND Giant cell tumors(GCT)are most commonly seen in the distal femur.These tumors are uncommon in the small bones of the hand and feet,and a very few cases have been reported.A giant cell tumor of the talus is rarely seen clinically and could be a challenge to physicians.CASE SUMMARY We report a rare case of GCT of the talus in one patient who underwent a new reconstructive surgery technique using a three-dimensional(3D)printing talar prosthesis.The prosthesis shape was designed by tomographic image processing and segmentation using technology to match the intact side by mirror symmetry with 3D post-processing technologies.The patient recovered nearly full range of motion of the ankle after 6 mo.The visual analogue scale and American Orthopaedic Foot and Ankle Society scores were 1 and 89 points,respectively.CONCLUSION We demonstrated that 3D printing of a talar prosthesis is a beneficial option for GCT of the talus.
基金supported by the National Key Research and Development Program Young Scientist Project(Grant No.2024YFC2911000)the National Natural Science Foundation of China(Grant No.52474103)the Major Basic Research Project of the Natural Science Foundation of Shandong Province(Grant No.ZR2024ZD22).
文摘Internal structural defects in engineering rock masses vary in size,exhibit complex shapes,and are unevenly distributed.Dominant fractures within a rock mass often play a critical to its mechanical behavior,directly affecting the macromechanical properties and failure modes.These fractures affect the instability and failure of the surrounding rock,significantlyimpacting the overall stability of engineering structures.Herein,sand-powder three-dimensional(3D)printing technology was used to prepare rock-like specimens with internal fracture networks.Triaxial compression testing,post-failure fracture mapping,and fractal dimension analysis of the fracture surfaces were conducted to investigate the effects of dominant fracture angles on the strength and deformation of rocks with internal fracture networks under triaxial stress.The results indicate that the dominant fracture angle has a pronounced effect on the mechanical behavior of rock.With increasing angle,both compressive strength and elastic modulus exhibit an initial decline followed by an increase.Moreover,higher confiningpressure significantlyimproves the compressive strength of fractured rock.This enhancement weakens as the confiningpressure further increases.Moreover,with increasing confiningpressure,the differences between the maximum and minimum values of elastic moduli and lateral strain ratios in fractured rock gradually decrease.Thus,the impact of the dominant fracture angle on rock mass deformation decreases with increasing confiningpressure.This research elucidates the effects of dominant fracture angles on the mechanical and failure properties of complex fractured rock masses and the influenceof the confiningpressure on these relationships.It provides valuable theoretical insights and practical guidance for stability analyses in engineering rock masses.
文摘BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning.
文摘Background: As the population age structure gradually ages, more and more elderly people were found to have pulmonary nodules during physical examinations. Most elderly people had underlying diseases such as heart, lung, brain and blood vessels and cannot tolerate surgery. Computed tomography (CT)-guided percutaneous core needle biopsy (CNB) was the first choice for pathological diagnosis and subsequent targeted drugs, immune drugs or ablation treatment. CT-guided percutaneous CNB requires clinicians with rich CNB experience to ensure high CNB accuracy, but it was easy to cause complications such as pneumothorax and hemorrhage. Three-dimensional (3D) printing coplanar template (PCT) combined with CT-guided percutaneous pulmonary CNB biopsy has been used in clinical practice, but there was no prospective, randomized controlled study. Methods: Elderly patients with lung nodules admitted to the Department of Oncology of our hospital from January 2019 to January 2023 were selected. A total of 225 elderly patients were screened, and 30 patients were included after screening. They were randomly divided into experimental group (Group A: 30 cases) and control group (Group B: 30 cases). Group A was given 3D-PCT combined with CT-guided percutaneous pulmonary CNB biopsy, Group B underwent CT-guided percutaneous pulmonary CNB. The primary outcome measure of this study was the accuracy of diagnostic CNB, and the secondary outcome measures were CNB time, number of CNB needles, number of pathological tissues and complications. Results: The diagnostic accuracy of group A and group B was 96.67% and 76.67%, respectively (P = 0.026). There were statistical differences between group A and group B in average CNB time (P = 0.001), number of CNB (1 vs more than 1, P = 0.029), and pathological tissue obtained by CNB (3 vs 1, P = 0.040). There was no statistical difference in the incidence of pneumothorax and hemorrhage between the two groups (P > 0.05). Conclusions: 3D-PCT combined with CT-guided percutaneous CNB can improve the puncture accuracy of elderly patients, shorten the puncture time, reduce the number of punctures, and increase the amount of puncture pathological tissue, without increasing pneumothorax and hemorrhage complications. We look forward to verifying this in a phase III randomized controlled clinical study. .
文摘The intricate anatomy of the corpus cavernosum in both the flaccid and tumescent state has not been fully elucidated. We report our experience using a three-dimensional (3D) scanner to reconstruct cadaveric casts and compare them with 3D images of two prototypes of penile prosthesis. Two different models of the Titan Coloplast inflatable penile prosthesis were analyzed using a 3D scanner. The first was the standard model and the second was a newer model with a rounder silicone tip. Two cadaveric phalluses were harvested using Smooth-Cast 300Q polyurethane molding. The molds were excised and scanned along side the penile prosthesis. 3D scans were completed and analyzed using Leios Mesh software, and GOM Inspect software. The 3D scans demonstrated the mean human corporal radii 2 mm from the distal tip to be 36.51 mm (36.01-37.0 mm), which is an obtuse angle. The standard Titan penile prosthesis spherical radius at the same level was 202.52 mm, while the new silicone tip prosthesis had a radius of 139.33 mm. 3D mapping further demonstrated the trajectory of the cavernosa appeared curvilinear and the distal ends appeared blunt. The use of cadaveric cavernosal molds in combination with the 3D scanner allowed us to accurately image the corpus cavernosum for the first time. Our findings suggest that anatomically accurate corporal tips appear to be relatively blunt and that the new Titan silicone tip penile prosthesis more closely resembles the human corporal tip.
基金supported by the National Natural Science Foundation of China(Grant no.42207232)the Sichuan Science and Technology Plan Project(2023YFS0444)+1 种基金the Transportation Technology Project of Sichuan Province(2021-A-04)the State Key Laboratory of Geohazard Prevention and Geoenvironment Protection Independent Research Project(SKLGP2021Z001,SKLGP2022Z023)。
文摘This study investigated the resilience of traditional concrete dams compared to 3D printed concrete dams(3DPC)when subjected to debris flow.Three types of dams,namely check dams,arch dams,and curve dams,were numerically analyzed using a three-dimensional Coupled Eulerian-Lagrangian(CEL)methodology.The research focused on critical factors such as impact force and viscous energy dissipation to compare dam performance.Additionally,the study examined the printing and service phases of 3DPC models,determining potential failure modes and analyzing printing parameters.The results demonstrated that 3DPC dams outperformed traditional concrete dams,with filament deposition orientation,perpendicular to the debris flow direction,identified as a pivotal factor.Infill percentage and pattern were also found to influence the behavior of 3DPC models.Notably,curved dams exhibited superior performance based on dam geometry.These findings have significant potential for advancing the development of resilient dam structures capable of withstanding debris flow impacts.
基金This study was supported by the following funds:National Key R&D Program of China(No.2018YFE0207900)Program for Innovation Team of Shaanxi Province(No.2023-CXTD-17)+5 种基金Program of the National Natural Science Foundation of China(No.51835010)Key R&D Program of Guangdong Province(No.2018B090906001)Natural Science Basic Research Program of Shaanxi Province(No.2022JQ-378)China Postdoctoral Science Foundation(No.2020M683458)Fundamental Research Funds for the Central Universities(8)Youth Innovation Team of Shaanxi Universities.
文摘Based on the building principle of additive manufacturing,printing orientation mainly determines the tribological properties of joint prostheses.In this study,we created a polyether-ether-ketone(PEEK)joint prosthesis using fused filament fabrication and investigated the effects of printing orientation on its tribological properties using a pin-on-plate tribometer in 25% newborn calf serum.An ultrahigh molecular weight polyethylene transfer film is formed on the surface of PEEK due to the mechanical capture of wear debris by the 3D-printed groove morphology,which is significantly impacted by the printing orientation of PEEK.When the printing orientation was parallel to the sliding direction of friction,the number and size of the transfer film increased due to higher steady stress.This transfer film protected the matrix and reduced the friction coefficient and wear rate of friction pairs by 39.13%and 74.33%,respectively.Furthermore,our findings provide a novel perspective regarding the role of printing orientation in designing knee prostheses,facilitating its practical applications.
文摘The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology)by one surgeon at a single hospital were studied.The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule.Data collected included the operative duration,the blood loss,the damage of the important tissue,the biographic union and therecovery of the function after the operation.Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits.The scores of reduction and function were measured during follow-up.Results showed that the wounds of 30 patients were healed in the first stage,and there was no injury of important structures such as blood vessels and nerves.According to the Matta criteria,excellent effectiveness was obtained in 22 cases and good in 8 cases.According to the functional evaluation criteria of Majeed,excellent effectiveness was obtained in 21 cases and good in 9 cases.It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation,which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved,and better surgical result was finally achieved.
基金This work was supported by the National Key Research and Development Program,China(No.2018YFB1106600)National Science and Technology Major Project,China(No.2017-VI-0002–0072 and No.Y2019-VII-0011-0151).
文摘The increasing demand for geometrically complex structures—specifically, higher-inlet-temperature turbine blades for the fifth-generation or other high-generation machines of advanced fighter aircrafts—hasmade the development of more complex double-walled three-layer hollow-cavity structures a necessity.However, this requires the preparation of complex ceramic cores and advanced, integrated technologies.Stereolithographic three-dimensional printing (SLA-3DP) technology, with digital control upon materialmorphology, composition, and structure, is a high integration and versatile technique that is superior tothe traditional manufacturing techniques for ceramic cores, including gel casting, injection molding, andhot pressing. The latent capacity of this technique is contingent on the progress of processing routesthat significantly reduce the distortion and defect formation in response to the elimination of the reactedorganic monomer phase during photo-curing. Despite the tremendous progress in the field, multiple challenges remain, such as the preparation of high-solid-content and low-viscosity suspensions, SLA-3DP oflarge double-walled ceramic cores with complex structures, and process optimization and sinter strengthening for the fabrication of ceramic cores. These challenges have prevented the broader applications andreduced the impact of the SLA-3DP technology. This review discusses cutting-edge research on the crucialfactors governing this production method. Specifically, we outline the existing challenges within the fieldand provide our perspective on the upcoming research work and progress.
文摘BACKGROUND With the increasing complexity of surgical interventions performed in orthopaedic trauma surgery and the improving technologies used in threedimensional(3D)printing,there has been an increased interest in the concept.It has been shown that 3D models allow surgeons to better visualise anatomy,aid in planning and performing complex surgery.It is however not clear how best to utilise the technique and whether this results in better outcomes.AIM To evaluate the effect of 3D printing used in pre-operative planning in orthopaedic trauma surgery on clinical outcomes.METHODS We performed a comprehensive systematic review of the literature and a metaanalysis.Medline,Ovid and Embase were searched from inception to February 8,2018.Randomised controlled trials,case-control studies,cohort studies and case series of five patients or more were included across any area of orthopaedic trauma.The primary outcomes were operation time,intra-operative blood loss and fluoroscopy used.RESULTS Seventeen studies(922 patients)met our inclusion criteria and were reviewed.The use of 3D printing across all specialties in orthopaedic trauma surgery demonstrated an overall reduction in operation time of 19.85%[95%confidence intervals(CI):(-22.99,-16.71)],intra-operative blood loss of 25.73%[95%CI:(-31.07,-20.40)],and number of times fluoroscopy was used by 23.80%[95%CI:(-38.49,-9.10)].CONCLUSION Our results suggest that the use of 3D printing in pre-operative planning in orthopaedic trauma reduces operative time,intraoperative blood loss and the number of times fluoroscopy is used.
文摘This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to December 2016),in which the guiding template printed by the three-dimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis,was performed.Totally,4 males and 3 females were included in template group,aged from 38to 65years old (mean 50.86±8.90).Of them,5 had sacral fractures (3 with Denis type Ⅰ and 2 with type Ⅱ)and 2 the separation of sacroiliac joint.Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out.A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively.The time of each screw insertion,volume of intra-operative blood loss,and the exposure to X ray were analyzed and the Matta's radiological criteria were used to evaluate the reduction quality.The Majeed score was used to evaluate postoperative living quality.The visual analogue scale (VAS)was applied at different time points to judge pain relief of coccydynia.All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months,mean (16.57±2.44)months.Totally 9 sacroiliac screws for the S 1 and S2 vertebra were inserted in the 7 patients.The time length for each screw insertion ranged from 450 to 870 s,mean (690.56±135.68)s,and the number of times of exposure to X ray were 4 to 8,mean (5.78±1.20).The intra-operative blood loss ranged from 45to 120 mL,mean (75±23.32)mL.According to Matta's radiology criteria,the fracture and dislocation reduction were excellent in 6cases and good in 1.The pre-operative VAS score ranged from 5.2 to 8.1,mean (7.13±1.00).The average one-week/six-month post-operative VAS was (5.33±0.78)and (1.33±0.66),respectively (P<0.05 when compared with pre-operative VAS).The 12-month post-operative Majeed score ranged from 86 to 92,mean (90.29±2.21).The three-dimensional printed guiding template for sacroiliac screw insertion,which could significantly shorten the operation time,provide a satisfied outcome of the stabilization of the pelvic ring,and protect doctors and patients from X-ray exposure,might be a practical and valuable new clinical technique.
文摘As an emerging technology to promote the combination of medicine and industry,the three-dimensional(3D)printing has developed rapidly in the fields of orthopedics,while its unique advantages in improving precise treatment still need to be further popularized.In this report,our team have exhibited several classic cases of integrating 3D printing into orthopedic clinical application,thereby further elaborating thoughts and opinions on the significance of 3D printing in the orthopedic clinical application,technical advantages,existing main problems and coping strategies.
基金This study was supported by the National key R&D plan(No.2020YFC2008100)the Science and Technology Innovation Team Project of the Shaanxi Innovation Capability Support Plan(No.S2020-ZC-TD-0029)the Science Foundation for Distinguished Young Scholars of Shaanxi Natural Science Basic Research Program(No.S2018-JC-JQ-0094)。
文摘Heart diseases remain the top threat to human health,and the treatment of heart diseases changes with each passing day.Convincing evidence shows that three-dimensional(3D)printing allows for a more precise understanding of the complex anatomy associated with various heart diseases.In addition,3D-printed models of cardiac diseases may serve as effective educational tools and for hands-on simulation of surgical interventions.We introduce examples of the clinical applications of different types of 3D printing based on specific cases and clinical application scenarios of 3D printing in treating heart diseases.We also discuss the limitations and clinically unmet needs of 3D printing in this context.
文摘Hepatocellular carcinoma(HCC)constitutes the fifth most frequent malignancy worldwide and the third most frequent cause of cancer-related deaths.Currently,treatment selection is based on the stage of the disease.Emerging fields such as three-dimensional(3D)printing,3D bioprinting,artificial intelligence(AI),and machine learning(ML)could lead to evidence-based,individualized management of HCC.In this review,we comprehensively report the current applications of 3D printing,3D bioprinting,and AI/ML-based models in HCC management;we outline the significant challenges to the broad use of these novel technologies in the clinical setting with the goal of identifying means to overcome them,and finally,we discuss the opportunities that arise from these applications.Notably,regarding 3D printing and bioprinting-related challenges,we elaborate on cost and cost-effectiveness,cell sourcing,cell viability,safety,accessibility,regulation,and legal and ethical concerns.Similarly,regarding AI/ML-related challenges,we elaborate on intellectual property,liability,intrinsic biases,data protection,cybersecurity,ethical challenges,and transparency.Our findings show that AI and 3D printing applications in HCC management and healthcare,in general,are steadily expanding;thus,these technologies will be integrated into the clinical setting sooner or later.Therefore,we believe that physicians need to become familiar with these technologies and prepare to engage with them constructively.
基金supported by grants from the Human Resources Development program(Grant No.20204010600250)the Training Program of CCUS for the Green Growth(Grant No.20214000000500)by the Korea Institute of Energy Technology Evaluation and Planning(KETEP)funded by the Ministry of Trade,Industry,and Energy of the Korean Government(MOTIE).
文摘Three-dimensional printing(3DP)offers valuable insight into the characterization of natural rocks and the verification of theoretical models due to its high reproducibility and accurate replication of complex defects such as cracks and pores.In this study,3DP gypsum samples with different printing directions were subjected to a series of uniaxial compression tests with in situ micro-computed tomography(micro-CT)scanning to quantitatively investigate their mechanical anisotropic properties and damage evolution characteristics.Based on the two-dimensional(2D)CT images obtained at different scanning steps,a novel void ratio variable was derived using the mean value and variance of CT intensity.Additionally,a constitutive model was formulated incorporating the proposed damage variable,utilizing the void ratio variable.The crack evolution and crack morphology of 3DP gypsum samples were obtained and analyzed using the 3D models reconstructed from the CT images.The results indicate that 3DP gypsum samples exhibit mechanical anisotropic characteristics similar to those found in naturally sedimentary rocks.The mechanical anisotropy is attributed to the bedding planes formed between adjacent layers and pillar-like structures along the printing direction formed by CaSO_(4)·2H_(2)O crystals of needle-like morphology.The mean gray intensity of the voids has a positive linear relationship with the threshold value,while the CT variance and void ratio have concave and convex relationships,respectively.The constitutive model can effectively match the stress–strain curves obtained from uniaxial compression experiments.This study provides comprehensive explanations of the failure modes and anisotropic mechanisms of 3DP gypsum samples,which is important for characterizing and understanding the failure mechanism and microstructural evolution of 3DP rocks when modeling natural rock behavior.
基金supported by the National Natural Science Foundation of China,No.81301050,81401067,81271392,81471275,81541034the Natural Science Foundation of Tianjin City of China,No.14JCQNJC10200,15JCQNJC11100,16JCYBJC27600
文摘Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to create customized scaffolds with high precision and accuracy. In this study, an electrically controlled cortical impactor was used to induce randomized brain tissue defects. The overall shape of scaffolds was designed using rat-specific anatomical data obtained from magnetic resonance imaging, and the internal structure was created by computer- aided design. As the result of limitations arising from insufficient resolution of the manufacturing process, we magnified the size of the cavity model prototype five-fold to successfully fabricate customized collagen-chitosan scaffolds using three-dimensional printing. Results demonstrated that scaffolds have three-dimensional porous structures, high porosity, highly specific surface areas, pore connectivity and good internal characteristics. Neural stem cells co-cultured with scaffolds showed good viability, indicating good biocompatibility and biodegradability. This technique may be a promising new strategy for regenerating complex damaged brain tissues, and helps pave the way toward personalized medicine.
基金Supported by the Health Commission of Fuyang City,No.FY2021-18Bengbu Medical College of Bengbu City,No.2023byzd215the Health Commission Anhui Provence,No.AHWJ2023BAa20164.
文摘BACKGROUND Prior studies have shown that preserving the left colic artery(LCA)during laparo-scopic radical resection for rectal cancer(RC)can reduce the occurrence of anasto-motic leakage(AL),without compromising oncological outcomes.However,anatomical variations in the branches of the inferior mesenteric artery(IMA)and LCA present significant surgical challenges.In this study,we present our novel three dimensional(3D)printed IMA model designed to facilitate preoperative rehearsal and intraoperative navigation to analyze its impact on surgical safety.AIM To investigate the effect of 3D IMA models on preserving the LCA during RC surgery.METHODS We retrospectively collected clinical dates from patients with RC who underwent laparoscopic radical resection from January 2022 to May 2024 at Fuyang People’s Hospital.Patients were divided into the 3D printing and control groups for sta-tistical analysis of perioperative characteristics.RESULTS The 3D printing observation group comprised of 72 patients,while the control group comprised 68 patients.The operation time(174.5±38.2 minutes vs 198.5±49.6 minutes,P=0.002),intraoperative blood loss(43.9±31.3 mL vs 58.2±30.8 mL,P=0.005),duration of hospitalization(13.1±3.1 days vs 15.9±5.6 days,P<0.001),postoperative recovery time(8.6±2.6 days vs 10.5±4.9 days,P=0.007),and the postoperative complication rate(P<0.05)were all significantly lower in the observation group.CONCLUSION Utilization of a 3D-printed IMA model in laparoscopic radical resection of RC can assist surgeons in understanding the LCA anatomy preoperatively,thereby reducing intraoperative bleeding and shortening operating time,demonstrating better clinical application potential.
文摘A new type of implantable drug delivery devices ( DDD ) with complicated architectures were fubricated by three-dimensional printing technique, employing levofloxacin (LVFX) as a model drug. Processing parameters were optimized in riew of the layer thickness, spucing between printed lines, flow rate of liquid binder and the fast axis speed. The prepared DDD prototype consists of a double-layer structure, of which the upper region is a reservoir system and the lower region is a matrix one. The in vitro release test revealed that LVFX was released in a dual-puse pattern. This DDD may present a new strategy for the prophylaxis and treatment of diseases such as bone infection in the near future.