BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are ne...BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are necessary.However,due to differences in race and sex,people’s body shapes vary.According to European guidelines,the patch should measure 10 cm×15 cm.If any part of the MPO is dissected,injury to the nerves,vascular network,or organs may occur during surgery,thereby leading to inguinal discomfort,pain,and seroma formation after surgery.Therefore,accurate localization and measurement of the boundary of the MPO are crucial for selecting the optimal patch for inguinal hernia repair.AIM To compare the size of the MPO measured on three-dimensional multislice spiral computed tomography(CT)with that measured via laparoscopy and explore the relevant factors influencing the size of the MPO.METHODS Clinical data from 74 patients who underwent laparoscopic tension-free inguinal hernia repair at the General Surgery Department of the First Affiliated Hospital of Anhui University of Science and Technology between September 2022 and July 2024 were collected and analyzed retrospectively.Transabdominal preperitoneal was performed.Sixty-four males and 10 females,with an average age of 58.30±12.32 years,were included.The clinical data of the patients were collected.The boundary of the MPO was measured on three-dimensional CT images before surgery and then again during transabdominal preperitoneal.All the preoperative and intraoperative data were analyzed via paired t-tests.A t-test was used for comparisons of age,body mass index,and sex between the groups.In the comparative analysis,a P value less than 0.05 indicated a significant difference.RESULTS The boundaries of the MPO on 3-dimensional CT images measured 7.05±0.47 cm and 6.27±0.61 cm,and the area of the MPO was 19.54±3.33 cm^(2).The boundaries of the MPO during surgery were 7.18±0.51 cm and 6.17±0.40 cm.The errors were not statistically significant.However,the intraoperative BD(the width of the MPO,P=0.024,P<0.05)and preoperative AC(the length of the MPO,P=0.045,P<0.05)significantly differed according to sex.The AC and BD measurements before and during surgery were not significantly different according to age,body mass index,hernia side or hernia type(P>0.05).CONCLUSION The application of this technology can aid in determining the most appropriate dissection range and patch size.展开更多
Oceanic dissolved oxygen(DO)concentration is crucial for assessing the status of marine ecosystems.Against the backdrop of global warming,DO shows a general decrease,posing a threat to the health of marine ecosystems....Oceanic dissolved oxygen(DO)concentration is crucial for assessing the status of marine ecosystems.Against the backdrop of global warming,DO shows a general decrease,posing a threat to the health of marine ecosystems.Therefore,there is an urgent need to develop advanced tools to characterize the spatio-temporal variations of three-dimensional(3D)DO.To address this challenge,this study introduces the Light Gradient Boosting Machine(Light-GBM),combining satellite remote sensing and reanalysis data with Biogeochemical Argo data to accurately reconstruct the 3D DO structure in the Mediterranean Sea from 2010 to 2022.Various environmental parameters are incorporated as inputs,including spatiotemporal features,meteorological characteristics,and ocean color properties.The LightGBM model demonstrates excellent performance on the testing dataset with R^(2) of 0.958.The modeled DO agrees better with in-situ measurements than products from numerical models.Using the Shapley Additive exPlanations method,the contributions of input features are assessed.Sea surface temperatures provide a correlation with DO at the sea surface,while spatial coordinates supplement the view of the ocean interior.Based on the reconstructed 3D DO structure,we identify an oxygen minimum zone in the western Mediterranean that expands continuously,reaching depths of approximately 300–800 m.The western Mediterranean exhibits a significant declining trend.This study enhances marine environmental evidence by proposing a precise and cost-effective approach for reconstructing 3D DO,thereby offering insights into the dynamics of DO variations under changing climatic conditions.展开更多
BACKGROUND Percutaneous transhepatic biliary drainage(PTBD)is one of the primary clinical treatment options for patients with obstructive jaundice.In recent years,PTBD assisted by three-dimensional(3D)reconstruction t...BACKGROUND Percutaneous transhepatic biliary drainage(PTBD)is one of the primary clinical treatment options for patients with obstructive jaundice.In recent years,PTBD assisted by three-dimensional(3D)reconstruction technology has been widely implemented,but its advantages over traditional methods remains inconclusive.Thus,a discussion is warranted.AIM To explore the safety and efficacy of 3D reconstruction technology-assisted PTBD.METHODS We systematically searched the databases including the Cochrane Library,PubMed,EMBASE,Web of Science and China National Knowledge Infrastructure.The search period extended from the establishment of each database to November,2024.We screened the literature according to predefined inclusion and exclusion criteria,assessed the quality of the studies,and extracted data.Meta-analysis was performed using Revman 5.4.1 software.RESULTS A total of 15 studies were included,involving 1434 patients.The results of the meta-analysis showed that compared with the traditional group,the overall post-operative complications rate in the 3D reconstruction technology group was significantly lower[odds ratio=0.25;95%confidence interval(CI):0.17-0.36,P<0.00001].The overall puncture success rate in the 3D reconstruction group was better than those in the traditional group(odds ratio=3.61;95%CI:1.98-6.55,P<0.0001).However,there was no significant difference between the two groups in the reduction levels of postoperative total bilirubin(mean difference=-1.38;95%CI:-3.29 to 0.53,P=0.16).Subgroup analysis were conducted on the surgery time according to guidance stages of the 3D reconstruction,3D reconstruction imaging modalities,and types of studies.The results were stable,with no significant changes observed.CONCLUSION 3D reconstruction technology significantly improves the puncture success rate and safety of PTBD.However,it has no significant advantage in bile drainage effectiveness.Continued research is warranted to further explore its clinical value and optimize its application.展开更多
Fracture surface contour study is one of the important requirements for characterization and evaluation of the microstructure of rocks.Based on the improved cube covering method and the 3D contour digital reconstructi...Fracture surface contour study is one of the important requirements for characterization and evaluation of the microstructure of rocks.Based on the improved cube covering method and the 3D contour digital reconstruction model,this study proposes a quantitative microstructure characterization method combining the roughness evaluation index and the 3D fractal dimension to study the change rule of the fracture surface morphology after blasting.This method was applied and validated in the study of the fracture microstructure of the rock after blasting.The results show that the fracture morphology characteristics of the 3D contour digital reconstruction model have good correlation with the changes of the blasting action.The undulation rate of the three-dimensional surface profile of the rock is more prone to dramatic rise and dramatic fall morphology.In terms of tilting trend,the tilting direction also shows gradual disorder,with the tilting angle increasing correspondingly.All the roughness evaluation indexes of the rock fissure surface after blasting show a linear and gradually increasing trend as the distance to the bursting center increases;the difference between the two-dimensional roughness evaluation indexes and the three-dimensional ones of the same micro-area rock samples also becomes increasingly larger,among which the three-dimensional fissure roughness coefficient JRC and the surface roughness ratio Rs display better correlation.Compared with the linear fitting formula of the power function relationship,the three-dimensional fractal dimension of the postblast fissure surface is fitted with the values of JRC and Rs,which renders higher correlation coefficients,and the degree of linear fitting of JRC to the three-dimensional fractal dimension is higher.The fractal characteristics of the blast-affected region form a unity with the three-dimensional roughness evaluation of the fissure surface.展开更多
Abstract Objective: To evaluate the diagnostic value of two-phase multidetector-row spiral CT threedimensional reconstruction technique in TNM staging of gastric cancer. Methods: In 29 patients with gastric carcinom...Abstract Objective: To evaluate the diagnostic value of two-phase multidetector-row spiral CT threedimensional reconstruction technique in TNM staging of gastric cancer. Methods: In 29 patients with gastric carcinoma pathologically conformed, plan scans were done firstly. Two-phase spiral CT was performed within one breathhold each. Distension of the stomach was achieved by intravenous application of anisodamine and effervescent granules. After bolus injection of contrast medium, scanning was performed in the arterial and venous phase, and the source images were thin reconstructed. The stomach to three-dimension analysis was constructed by volume rendering (VR) multiplanaz volume reconstruction (MPVR), shaded surface display (SSD) and CT virtual gastroscopy (CTVG) technique. In combination with the sources images, gastric tumour invasion and lymph node metastasis was assessed, and TNM staging was performed. Results: In 29 cases of gastric carcinoma, the sensitivity and specificity of two-phase multidetector-row spiral CT three-dimensional reconstruction technique in T1, T2, T3 and Ta staging, the sensitivity and specificity was 50% and 50%, 87.5% and 77.8%, 83.3% and 76.9% and 100% and 80% respectively. For the N staging, the sensitivity and specificity in No, N1, and N2 N3 was 83.3% and 71.4%, 87.5% and 77.8% and 81.8% and 75% respectively. The sensitivity and the specificity for M1 staging was 100%. Conclusion: The reconstruction technique in combination with 16-slices spiral-CT can perform TNM staging well and effectively guide the choice of the surgical procedures for gastric cancer.展开更多
In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is prop...In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is proposed. The second-order statistics based on texture features are analyzed to evaluate the scale stationarity of the training image. The multiple-point statistics of the training image are applied to obtain the multiple-point statistics stationarity estimation by the multi-point density function. The results show that the reconstructed 3D structures are closer to reality when the training image has better scale stationarity and multiple-point statistics stationarity by the indications of local percolation probability and two-point probability. Moreover, training images with higher multiple-point statistics stationarity and lower scale stationarity are likely to obtain closer results to the real 3D structure, and vice versa. Thus, stationarity analysis of the training image has far-reaching significance in choosing a better 2D thin section image for the 3D reconstruction of porous media. Especially, high-order statistics perform better than low-order statistics.展开更多
Under hydrothermal and solvothermal conditions,two novel cobalt-based complexes,{[Co_(2)(CIA)(OH)(1,4-dtb)]·3.2H_(2)O}n(HU23)and{[Co_(2)(CIA)(OH)(1,4-dib)]·3.5H2O·DMF}n(HU24),were successfully construct...Under hydrothermal and solvothermal conditions,two novel cobalt-based complexes,{[Co_(2)(CIA)(OH)(1,4-dtb)]·3.2H_(2)O}n(HU23)and{[Co_(2)(CIA)(OH)(1,4-dib)]·3.5H2O·DMF}n(HU24),were successfully constructed by coordinatively assembling the semi-rigid multidentate ligand 5-(1-carboxyethoxy)isophthalic acid(H₃CIA)with the Nheterocyclic ligands 1,4-di(4H-1,2,4-triazol-4-yl)benzene(1,4-dtb)and 1,4-di(1H-imidazol-1-yl)benzene(1,4-dib),respectively,around Co^(2+)ions.Single-crystal X-ray diffraction analysis revealed that in both complexes HU23 and HU24,the CIA^(3-)anions adopt aκ^(7)-coordination mode,bridging six Co^(2+)ions via their five carboxylate oxygen atoms and one ether oxygen atom.This linkage forms tetranuclear[Co4(μ3-OH)2]^(6+)units.These Co-oxo cluster units were interconnected by CIA^(3-)anions to assemble into 2D kgd-type structures featuring a 3,6-connected topology.The 2D layers were further connected by 1,4-dtb and 1,4-dib,resulting in 3D pillar-layered frameworks for HU23 and HU24.Notably,despite the similar configurations of 1,4-dtb and 1,4-dib,differences in their coordination spatial orientations lead to topological divergence in the 3D frameworks of HU23 and HU24.Topological analysis indicates that the frameworks of HU23 and HU24 can be simplified into a 3,10-connected net(point symbol:(4^(10).6^(3).8^(2))(4^(3))_(2))and a 3,8-connected tfz-d net(point symbol:(4^(3))_(2)((4^(6).6^(18).8^(4)))),respectively.This structural differentiation confirms the precise regulatory role of ligands on the topology of metal-organic frameworks.Moreover,the ultraviolet-visible absorption spectra confirmed that HU23 and HU24 have strong absorption capabilities for ultraviolet and visible light.According to the Kubelka-Munk method,their bandwidths were 2.15 and 2.08 eV,respectively,which are consistent with those of typical semiconductor materials.Variable-temperature magnetic susceptibility measurements(2-300 K)revealed significant antiferromagnetic coupling in both complexes,with their effective magnetic moments decreasing markedly as the temperature lowered.CCDC:2457554,HU23;2457553,HU24.展开更多
Through the introduction of disaster situation of Qiang Culture after Wenchuan Earthquake, the paper emphasized that carriers of Qiang Culture had been seriously damaged, the inheritance of Qiang Culture had been affe...Through the introduction of disaster situation of Qiang Culture after Wenchuan Earthquake, the paper emphasized that carriers of Qiang Culture had been seriously damaged, the inheritance of Qiang Culture had been affected, and the environment for Qiang Culture was difficult to recover. It highlighted that three-dimensional reconstruction of Qiang Culture should stress the core task and timely and effectively rescue endangered cultural heritages of Qiang Nationality from the perspectives of material and spiritual life. It had explained focuses of three-dimensional pattern construction in detail. In terms of spatial reconstruction, it should reconstruct native culture and history while material culture was constructed, and reconstruct Qiang culture highland by depending on aborigines; in terms of cluster reconstruction, it should give support to large tourism enterprises and perfect tourism chain; in terms of ecological reconstruction, it should enhance construction and demonstration of "ecological protection pilot area of Qiang culture"; in terms of development reconstruction, it should realize coordinated unity between protection and development according to classification protection, characteristic protection and key protection, so as to form the virtuous circle of post-disaster recovery protection and sustainable development.展开更多
Oil-fired construction machinery(OCM)is a major source of urban air pollutants and CO_(2) emissions,and elec-trification is a crucial pathway for improving air quality and achieving China’s dual carbon goals;however,...Oil-fired construction machinery(OCM)is a major source of urban air pollutants and CO_(2) emissions,and elec-trification is a crucial pathway for improving air quality and achieving China’s dual carbon goals;however,its feasibility has not been fully explored.This study uses data envelopment analysis and the analytic hierarchy process to establish a development potential index,covering technical efficiency,economic cost,application sce-narios,and charging time and range,with an empirical analysis conducted in Beijing.The findings indicated the high feasibility of replacing OCM with electric alternatives,especially within the low-power range.Based on 2023 registered coding dat1,it is projected that by 2030,electrification could reduce regional average con-centrations of CO,NO_(x),PM_(2.5) and VOCs by 12.2%to 56.4%and reduce CO_(2) by 11.7%to 56.9%.Owing to economic considerations,small-and medium-sized machinery are particularly feasible for electrification.Key recommendations include prioritizing the electrification of forklifts,lifting platforms,and small-sized machinery in high-emission areas,particularly in central urban districts.Policies such as carbon taxes,carbon markets,and performance grading systems are suggested to incentivize electrification,along with expanding high-emission restriction zones and improving energy infrastructure to support widespread electrification.展开更多
To advance intelligent construction,standards must come first.The Ministry of Housing and Urban-Rural Development has issued the List for Replicable Experience and Practices for Developing Intelligent Construction fou...To advance intelligent construction,standards must come first.The Ministry of Housing and Urban-Rural Development has issued the List for Replicable Experience and Practices for Developing Intelligent Construction four times successively and the Technical Guidelines for Intelligent Construction(Trial).展开更多
The development of graphene-based composites with low density,robust absorption,wide bandwidth and thin thickness remained a great challenge in the field of electromagnetic(EM)absorption.In this work,nitrogen-doped re...The development of graphene-based composites with low density,robust absorption,wide bandwidth and thin thickness remained a great challenge in the field of electromagnetic(EM)absorption.In this work,nitrogen-doped reduced graphene oxide/hollow cobalt ferrite(NRGO/hollow CoFe_(2)O_(4))composite aerogels were constructed by a solvothermal and hydrothermal two-step route.Results demonstrated that the as-fabricated composite aerogels had the ultralow density and a unique three-dimensional(3D)network structure,and lots of hollow CoFe_(2)O_(4)microspheres were almost homogeneously distributed on the wrinkled surfaces of lamellar NRGO.Moreover,superior EM absorbing capacity could be achieved by modulating the ferrite structure,addition amounts of hollow CoFe_(2)O_(4)and thicknesses.It was noteworthy that the NRGO/hollow CoFe_(2)O_(4)composite aerogel with the addition amount of ferrite of 15.0 mg pos-sessed the minimum reflection loss of-44.7 dB and maximum absorption bandwidth of 5.2 GHz(from 12.6 to 17.8 GHz)at a very thin thickness of 1.8 mm and filling ratio of 15.0 wt.%.Furthermore,the possible EM attenuation mechanism had been proposed.The results of this work would be helpful for developing RGO-based 3D composites as lightweight,thin and highly efficient EM wave absorbers.展开更多
BACKGROUND Sigmoid colon cancer faces challenges due to anatomical diversity,including variable inferior mesenteric artery(IMA)branching and tumor localization complexities,which increase intraoperative risks.AIM To c...BACKGROUND Sigmoid colon cancer faces challenges due to anatomical diversity,including variable inferior mesenteric artery(IMA)branching and tumor localization complexities,which increase intraoperative risks.AIM To comprehensively evaluate the impact of three-dimensional(3D)visualization technology on enhancing surgical precision and safety,as well as optimizing perioperative outcomes in laparoscopic sigmoid cancer resection.METHODS A prospective cohort of 106 patients(January 2023 to December 2024)undergoing laparoscopic sigmoid cancer resection was divided into the 3D(n=55)group and the control(n=51)group.The 3D group underwent preoperative enhanced computed tomography reconstruction(3D Slicer 5.2.2&Mimics 19.0).3D reconstruction visualization navigation intraoperatively guided the following key steps:Tumor location,Toldt’s space dissection,IMA ligation level selection,regional lymph node dissection,and marginal artery preservation.Outcomes included operative parameters,lymph node yield,and recovery metrics.RESULTS The 3D group demonstrated a significantly shorter operative time(172.91±20.69 minutes vs 190.29±32.29 minutes;P=0.002),reduced blood loss(31.5±11.8 mL vs 44.1±23.4 mL,P=0.001),earlier postoperative flatus(2.23±0.54 days vs 2.53±0.61 days;P=0.013),shorter hospital length of stay(13.47±1.74 days vs 16.20±7.71 days;P=0.013),shorter postoperative length of stay(8.6±2.6 days vs 10.5±4.9 days;P=0.014),and earlier postoperative exhaust time(2.23±0.54 days vs 2.53±0.61 days;P=0.013).Furthermore,the 3D group exhibited a higher mean number of lymph nodes harvested(16.91±5.74 vs 14.45±5.66;P=0.030).CONCLUSION The 3D visualization technology effectively addresses sigmoid colon anatomical complexity through surgical navigation,improving procedural safety and efficiency.展开更多
An automatic three-dimensional(3D) reconstruction method based on four-view stereo vision using checkerboard pattern is presented. Mismatches easily exist in traditional binocular stereo matching due to the repeatable...An automatic three-dimensional(3D) reconstruction method based on four-view stereo vision using checkerboard pattern is presented. Mismatches easily exist in traditional binocular stereo matching due to the repeatable or similar features of binocular images. In order to reduce the probability of mismatching and improve the measure precision, a four-camera measurement system which can add extra matching constraints and offer multiple measurements is applied in this work. Moreover, a series of different checkerboard patterns are projected onto the object to obtain dense feature points and remove mismatched points. Finally, the 3D model is generated by performing Delaunay triangulation and texture mapping on the point cloud obtained by four-view matching. This method was tested on the 3D reconstruction of a terracotta soldier sculpture and the Buddhas in the Mogao Grottoes. Their point clouds without mismatched points were obtained and less processing time was consumed in most cases relative to binocular matching. These good reconstructed models show the effectiveness of the method.展开更多
Three-dimensional graphene/conducting polymer(3DGCP) composites have received significant attention in recent years due to their unique structures and promising applications in energy storage.With the structural div...Three-dimensional graphene/conducting polymer(3DGCP) composites have received significant attention in recent years due to their unique structures and promising applications in energy storage.With the structural diversity of graphene and π-functional conducting polymers via rich chemical routes,a number of 3DGCP composites with novel structures and attractive performance have been developed.Particularly,the hierarchical porosity,the interactions between graphene and conducting polymers as well as the their synergetic effects within 3DGCP composites can be well combined and elaborated by various synthetic methods,which made 3DGCP composites show unique electrochemical properties and significantly improved performance in energy storage fields compared to other graphenebased composites.In this short review,we present recent advances in 3DGCP composites in developing effective strategies to prepare 3DGCP composites and exploring them as a unique platform for supercapacitors with unprecedented performance.The challenges and future opportunities are also discussed for promotion of further study.展开更多
A three-dimensional finite element simulation was carried out to investigate the effects of tunnel construction on nearby pile foundation.The displacement controlled model (DCM) was used to simulate the tunneling-indu...A three-dimensional finite element simulation was carried out to investigate the effects of tunnel construction on nearby pile foundation.The displacement controlled model (DCM) was used to simulate the tunneling-induced volume loss effects.The numerical model was verified based on the results of a centrifuge test and a set of parametric studies was implemented based on this model.There is good agreement between the trend of the results of the centrifuge test and the present model.The results of parametric studies show that the tunnelling-induced pile internal force and deformation depend mainly on the pile?tunnel distance,the pile length to tunnel depth ratio and the volume loss.Two different zones are separated by a 45° line projected from the tunnel springline.Within the zone of influence,the pile is subjected to tensile force and large settlement;whereas outside the zone of influence,dragload and small settlement are induced.It is also established that the impact of tunnelling on a pile group is substantially smaller as compared with a single pile in the same location with the rear pile in a group,demonstrating a positive pile group effect.展开更多
Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic memb...Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes(TMs).Methods: Middle ears were identified from 36 patients ranging 18-89 years of age with TM perforations who underwent tympanometry and temporal bone computed tomography(CT) between 2005 and 2015. MEVs calculated by both tympanometry and three-dimensional volume reconstruction(3DVR) were analyzed for agreement using Bland Altman plots. The differences between tympanometric and 3DVR MEV values for each given middle ear were characterized across MEV quartiles(1= smallest; 4= largest) and across increasing states of middle ear disease using Kruskale Wallis and Wilcoxon testing with Bonferroni correction.Results: Bland Altman plots demonstrated significant disagreement between MEV measurement techniques. Differences between tympanometric(T) and 3DVR MEV values were significantly greater with increasing average(i.e.(Tt3DVR)/2)) MEV per linear regression(p < 0.0001). Significance was demonstrated between fourth and first average MEV quartiles(p= 0.0024), fourth and second quartiles(p= 0.0024), third and first quartiles(p= 0.0048), and third and second quartiles(p= 0.048). Absolute MEV difference was not significantly different across varying states of middle ear disease(p= 0.44).Conclusion: Statistically and clinically significant disagreement was demonstrated between tympanometric and 3DVR MEV values. Studies that vary in MEV estimation techniques may be expected to demonstrate significantly different results. These preliminary results suggest that clinicians should endeavor to seek further confirmation when interpreting high tympanometric MEV values.展开更多
The purpose of this study was to establish a method for measuring the knee valgus angle from the ana- tomical and mechanical axes on three-dimensional reconstruction imaging models, and to use this method for estimati...The purpose of this study was to establish a method for measuring the knee valgus angle from the ana- tomical and mechanical axes on three-dimensional reconstruction imaging models, and to use this method for estimating an average knee valgus angle value for northern Chinese adults. Computed tomographic angiography data in DICOM format for 128 normal femurs from 64 adult subjects were chosen for analysis. After the femur images were subjected to three-dimensional reconstruction, the deepest point in the intercondylar notch (point A), the midpoint of the medullary cavity 20 cm above the knee-joint line (point B), and the landmark of the femoral head rotation center (point C) were identified on each three-dimensional model. The knee valgus angle was defined as the angle enclosed by the distal femoral anatomical axis (line AB) and the femoral mechanical axis (line AC). The average (mean+SD) of knee valgus angle for the 128 femurs was 6.20°±1.20° (range, 3.05° to 10.64°). Significant positive correlations were found between the knee valgus angles of the right and left sides and between the knee valgus angle and age. During total knee arthroplasty, choosing a valgus cut angle of approximately 6° may achieve a good result in reestablishing the natural mechanical alignment of the lower extremity for patients of northern Chinese ethnicity. Larger valgus cut angles should be chosen for older patients.展开更多
Three-dimensional(3D)reconstruction of human organs has gained attention in recent years due to advances in the Internet and graphics processing units.In the coming years,most patient care will shift toward this new p...Three-dimensional(3D)reconstruction of human organs has gained attention in recent years due to advances in the Internet and graphics processing units.In the coming years,most patient care will shift toward this new paradigm.However,development of fast and accurate 3D models from medical images or a set of medical scans remains a daunting task due to the number of pre-processing steps involved,most of which are dependent on human expertise.In this review,a survey of pre-processing steps was conducted,and reconstruction techniques for several organs in medical diagnosis were studied.Various methods and principles related to 3D reconstruction were highlighted.The usefulness of 3D reconstruction of organs in medical diagnosis was also highlighted.展开更多
Summary: A three-dimensional (3D) graphic model of a single-chain Fv (scFv) which was derived from an anti-human placental acidic isoferritin (PAF) monoclonal antibody (MAb) was construct- ed by a homologous protein...Summary: A three-dimensional (3D) graphic model of a single-chain Fv (scFv) which was derived from an anti-human placental acidic isoferritin (PAF) monoclonal antibody (MAb) was construct- ed by a homologous protein-predicting computer algorithm on Silicon graphic computer station. The structure, surface static electricity and hydrophobicity of scFv were investigated. Computer graphic modelling indicated that all regions of scFv including the linker, variable regions of the heavy (VH) and light (VL) chains were suitable. The VH region and the VL region were involved in composing the 'hydrophobic pocket'. The linker was drifted away VH and VL regions. The complementarity determining regions (CDRs) of VH and VL regions surrounded the 'hydrophobic pocket'. This study provides a theory basis for improving antibody affinity, investigating antibody structure and analyzing the functions of VH and VL regions in antibody activity.展开更多
Objective:The aim of the study was to evaluate three-dimensional virtual models(3DVMs)usefulness in the intraoperative assistance of minimally-invasive partial nephrectomy in highly complex renal tumors.Methods:At our...Objective:The aim of the study was to evaluate three-dimensional virtual models(3DVMs)usefulness in the intraoperative assistance of minimally-invasive partial nephrectomy in highly complex renal tumors.Methods:At our institution cT1-2N0M0 all renal masses with Preoperative Aspects and Dimensions Used for an Anatomical classification score≥10 treated with minimally-invasive partial nephrectomy were considered for the present study.For inclusion a baseline contrast-enhanced computed tomography in order to obtain 3DVMs,the baseline and postoperative serum creatinine as well as estimated glomerular filtration rate values were needed.These patients,in which 3DVMs were used to assist the surgeon in the planning and intraoperative guidance,were then compared with a control group of patients who underwent minimally-invasive partial nephrectomy with the same renal function assessments,but without 3DVMs.Multivariable logistic regression models were used to predict the margin,ischemia,and complication score achievement.Results:Overall,79 patients met the inclusion criteria and were compared with 143 complex renal masses without 3DVM assistance.The 3DVM group showed better postoperative outcomes in terms of baseline-weighted differential estimated glomerular filtration rate(-17.7%vs.-22.2%,p=0.03),postoperative complications(16.5%vs.23.1%,p=0.03),and major complications(Clavien Dindo>III,2.5%vs.5.6%,p=0.03).At multivariable logistic regression 3DVM assistance independently predicted higher rates of successful partial nephrectomy(odds ratio:1.42,p=0.03).Conclusion:3DVMs represent a useful tool to plan a tailored surgical approach in case of surgically complex masses.They can be used in different ways,matching the surgeon's needs from the planning phase to the demolitive and reconstructive phase,leading towards maximum safety and efficacy outcomes.展开更多
基金Supported by the 2022 Provincial Quality Engineering Project for Higher Education Institutions,No.2022sx031the 2023 Provincial Quality Engineering Project for Higher Education Institutions,No.2023jyxm1071.
文摘BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are necessary.However,due to differences in race and sex,people’s body shapes vary.According to European guidelines,the patch should measure 10 cm×15 cm.If any part of the MPO is dissected,injury to the nerves,vascular network,or organs may occur during surgery,thereby leading to inguinal discomfort,pain,and seroma formation after surgery.Therefore,accurate localization and measurement of the boundary of the MPO are crucial for selecting the optimal patch for inguinal hernia repair.AIM To compare the size of the MPO measured on three-dimensional multislice spiral computed tomography(CT)with that measured via laparoscopy and explore the relevant factors influencing the size of the MPO.METHODS Clinical data from 74 patients who underwent laparoscopic tension-free inguinal hernia repair at the General Surgery Department of the First Affiliated Hospital of Anhui University of Science and Technology between September 2022 and July 2024 were collected and analyzed retrospectively.Transabdominal preperitoneal was performed.Sixty-four males and 10 females,with an average age of 58.30±12.32 years,were included.The clinical data of the patients were collected.The boundary of the MPO was measured on three-dimensional CT images before surgery and then again during transabdominal preperitoneal.All the preoperative and intraoperative data were analyzed via paired t-tests.A t-test was used for comparisons of age,body mass index,and sex between the groups.In the comparative analysis,a P value less than 0.05 indicated a significant difference.RESULTS The boundaries of the MPO on 3-dimensional CT images measured 7.05±0.47 cm and 6.27±0.61 cm,and the area of the MPO was 19.54±3.33 cm^(2).The boundaries of the MPO during surgery were 7.18±0.51 cm and 6.17±0.40 cm.The errors were not statistically significant.However,the intraoperative BD(the width of the MPO,P=0.024,P<0.05)and preoperative AC(the length of the MPO,P=0.045,P<0.05)significantly differed according to sex.The AC and BD measurements before and during surgery were not significantly different according to age,body mass index,hernia side or hernia type(P>0.05).CONCLUSION The application of this technology can aid in determining the most appropriate dissection range and patch size.
基金supported by the Central Guiding Local Science and Technology Development Fund of Shandong-Yellow River Basin(No.YDZX2023019)Shandong Natural Science Foundation of China(Nos.ZR2020QF067 and ZR2023QD073)+6 种基金the Discipline Cluster Research Project of Qingdao University“Deep mining and intelligent prediction of multimodal big data for marine ecological disasters”(No.20240604)sourced from the International Argo Program and the national programs that contribute to it(https://argo.ucsd.edu)the CMEMS(http://marine.copernicus.eu/)the CDS(https://cds.climate.copernicus.eu/)the EMODnet(https://www.emodnet-chemistry.eu/)obtained from the ERA5(https://www.ecmwf.int)derived from the Glob Colour Project(http://globcolour.info).
文摘Oceanic dissolved oxygen(DO)concentration is crucial for assessing the status of marine ecosystems.Against the backdrop of global warming,DO shows a general decrease,posing a threat to the health of marine ecosystems.Therefore,there is an urgent need to develop advanced tools to characterize the spatio-temporal variations of three-dimensional(3D)DO.To address this challenge,this study introduces the Light Gradient Boosting Machine(Light-GBM),combining satellite remote sensing and reanalysis data with Biogeochemical Argo data to accurately reconstruct the 3D DO structure in the Mediterranean Sea from 2010 to 2022.Various environmental parameters are incorporated as inputs,including spatiotemporal features,meteorological characteristics,and ocean color properties.The LightGBM model demonstrates excellent performance on the testing dataset with R^(2) of 0.958.The modeled DO agrees better with in-situ measurements than products from numerical models.Using the Shapley Additive exPlanations method,the contributions of input features are assessed.Sea surface temperatures provide a correlation with DO at the sea surface,while spatial coordinates supplement the view of the ocean interior.Based on the reconstructed 3D DO structure,we identify an oxygen minimum zone in the western Mediterranean that expands continuously,reaching depths of approximately 300–800 m.The western Mediterranean exhibits a significant declining trend.This study enhances marine environmental evidence by proposing a precise and cost-effective approach for reconstructing 3D DO,thereby offering insights into the dynamics of DO variations under changing climatic conditions.
基金Supported by the Natural Science Foundation of Fujian Province,No.2022J011442.
文摘BACKGROUND Percutaneous transhepatic biliary drainage(PTBD)is one of the primary clinical treatment options for patients with obstructive jaundice.In recent years,PTBD assisted by three-dimensional(3D)reconstruction technology has been widely implemented,but its advantages over traditional methods remains inconclusive.Thus,a discussion is warranted.AIM To explore the safety and efficacy of 3D reconstruction technology-assisted PTBD.METHODS We systematically searched the databases including the Cochrane Library,PubMed,EMBASE,Web of Science and China National Knowledge Infrastructure.The search period extended from the establishment of each database to November,2024.We screened the literature according to predefined inclusion and exclusion criteria,assessed the quality of the studies,and extracted data.Meta-analysis was performed using Revman 5.4.1 software.RESULTS A total of 15 studies were included,involving 1434 patients.The results of the meta-analysis showed that compared with the traditional group,the overall post-operative complications rate in the 3D reconstruction technology group was significantly lower[odds ratio=0.25;95%confidence interval(CI):0.17-0.36,P<0.00001].The overall puncture success rate in the 3D reconstruction group was better than those in the traditional group(odds ratio=3.61;95%CI:1.98-6.55,P<0.0001).However,there was no significant difference between the two groups in the reduction levels of postoperative total bilirubin(mean difference=-1.38;95%CI:-3.29 to 0.53,P=0.16).Subgroup analysis were conducted on the surgery time according to guidance stages of the 3D reconstruction,3D reconstruction imaging modalities,and types of studies.The results were stable,with no significant changes observed.CONCLUSION 3D reconstruction technology significantly improves the puncture success rate and safety of PTBD.However,it has no significant advantage in bile drainage effectiveness.Continued research is warranted to further explore its clinical value and optimize its application.
基金National Key Research and Development Program of China,Grant/Award Number:2021YFC2902103National Natural Science Foundation of China,Grant/Award Number:51934001Fundamental Research Funds for the Central Universities,Grant/Award Number:2023JCCXLJ02。
文摘Fracture surface contour study is one of the important requirements for characterization and evaluation of the microstructure of rocks.Based on the improved cube covering method and the 3D contour digital reconstruction model,this study proposes a quantitative microstructure characterization method combining the roughness evaluation index and the 3D fractal dimension to study the change rule of the fracture surface morphology after blasting.This method was applied and validated in the study of the fracture microstructure of the rock after blasting.The results show that the fracture morphology characteristics of the 3D contour digital reconstruction model have good correlation with the changes of the blasting action.The undulation rate of the three-dimensional surface profile of the rock is more prone to dramatic rise and dramatic fall morphology.In terms of tilting trend,the tilting direction also shows gradual disorder,with the tilting angle increasing correspondingly.All the roughness evaluation indexes of the rock fissure surface after blasting show a linear and gradually increasing trend as the distance to the bursting center increases;the difference between the two-dimensional roughness evaluation indexes and the three-dimensional ones of the same micro-area rock samples also becomes increasingly larger,among which the three-dimensional fissure roughness coefficient JRC and the surface roughness ratio Rs display better correlation.Compared with the linear fitting formula of the power function relationship,the three-dimensional fractal dimension of the postblast fissure surface is fitted with the values of JRC and Rs,which renders higher correlation coefficients,and the degree of linear fitting of JRC to the three-dimensional fractal dimension is higher.The fractal characteristics of the blast-affected region form a unity with the three-dimensional roughness evaluation of the fissure surface.
基金This project was supported by a grant from the Natural Science Foundation of Hubei Province (No. 2002AB130)
文摘Abstract Objective: To evaluate the diagnostic value of two-phase multidetector-row spiral CT threedimensional reconstruction technique in TNM staging of gastric cancer. Methods: In 29 patients with gastric carcinoma pathologically conformed, plan scans were done firstly. Two-phase spiral CT was performed within one breathhold each. Distension of the stomach was achieved by intravenous application of anisodamine and effervescent granules. After bolus injection of contrast medium, scanning was performed in the arterial and venous phase, and the source images were thin reconstructed. The stomach to three-dimension analysis was constructed by volume rendering (VR) multiplanaz volume reconstruction (MPVR), shaded surface display (SSD) and CT virtual gastroscopy (CTVG) technique. In combination with the sources images, gastric tumour invasion and lymph node metastasis was assessed, and TNM staging was performed. Results: In 29 cases of gastric carcinoma, the sensitivity and specificity of two-phase multidetector-row spiral CT three-dimensional reconstruction technique in T1, T2, T3 and Ta staging, the sensitivity and specificity was 50% and 50%, 87.5% and 77.8%, 83.3% and 76.9% and 100% and 80% respectively. For the N staging, the sensitivity and specificity in No, N1, and N2 N3 was 83.3% and 71.4%, 87.5% and 77.8% and 81.8% and 75% respectively. The sensitivity and the specificity for M1 staging was 100%. Conclusion: The reconstruction technique in combination with 16-slices spiral-CT can perform TNM staging well and effectively guide the choice of the surgical procedures for gastric cancer.
基金The National Natural Science Foundation of China(No.60972130)
文摘In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is proposed. The second-order statistics based on texture features are analyzed to evaluate the scale stationarity of the training image. The multiple-point statistics of the training image are applied to obtain the multiple-point statistics stationarity estimation by the multi-point density function. The results show that the reconstructed 3D structures are closer to reality when the training image has better scale stationarity and multiple-point statistics stationarity by the indications of local percolation probability and two-point probability. Moreover, training images with higher multiple-point statistics stationarity and lower scale stationarity are likely to obtain closer results to the real 3D structure, and vice versa. Thus, stationarity analysis of the training image has far-reaching significance in choosing a better 2D thin section image for the 3D reconstruction of porous media. Especially, high-order statistics perform better than low-order statistics.
文摘Under hydrothermal and solvothermal conditions,two novel cobalt-based complexes,{[Co_(2)(CIA)(OH)(1,4-dtb)]·3.2H_(2)O}n(HU23)and{[Co_(2)(CIA)(OH)(1,4-dib)]·3.5H2O·DMF}n(HU24),were successfully constructed by coordinatively assembling the semi-rigid multidentate ligand 5-(1-carboxyethoxy)isophthalic acid(H₃CIA)with the Nheterocyclic ligands 1,4-di(4H-1,2,4-triazol-4-yl)benzene(1,4-dtb)and 1,4-di(1H-imidazol-1-yl)benzene(1,4-dib),respectively,around Co^(2+)ions.Single-crystal X-ray diffraction analysis revealed that in both complexes HU23 and HU24,the CIA^(3-)anions adopt aκ^(7)-coordination mode,bridging six Co^(2+)ions via their five carboxylate oxygen atoms and one ether oxygen atom.This linkage forms tetranuclear[Co4(μ3-OH)2]^(6+)units.These Co-oxo cluster units were interconnected by CIA^(3-)anions to assemble into 2D kgd-type structures featuring a 3,6-connected topology.The 2D layers were further connected by 1,4-dtb and 1,4-dib,resulting in 3D pillar-layered frameworks for HU23 and HU24.Notably,despite the similar configurations of 1,4-dtb and 1,4-dib,differences in their coordination spatial orientations lead to topological divergence in the 3D frameworks of HU23 and HU24.Topological analysis indicates that the frameworks of HU23 and HU24 can be simplified into a 3,10-connected net(point symbol:(4^(10).6^(3).8^(2))(4^(3))_(2))and a 3,8-connected tfz-d net(point symbol:(4^(3))_(2)((4^(6).6^(18).8^(4)))),respectively.This structural differentiation confirms the precise regulatory role of ligands on the topology of metal-organic frameworks.Moreover,the ultraviolet-visible absorption spectra confirmed that HU23 and HU24 have strong absorption capabilities for ultraviolet and visible light.According to the Kubelka-Munk method,their bandwidths were 2.15 and 2.08 eV,respectively,which are consistent with those of typical semiconductor materials.Variable-temperature magnetic susceptibility measurements(2-300 K)revealed significant antiferromagnetic coupling in both complexes,with their effective magnetic moments decreasing markedly as the temperature lowered.CCDC:2457554,HU23;2457553,HU24.
文摘Through the introduction of disaster situation of Qiang Culture after Wenchuan Earthquake, the paper emphasized that carriers of Qiang Culture had been seriously damaged, the inheritance of Qiang Culture had been affected, and the environment for Qiang Culture was difficult to recover. It highlighted that three-dimensional reconstruction of Qiang Culture should stress the core task and timely and effectively rescue endangered cultural heritages of Qiang Nationality from the perspectives of material and spiritual life. It had explained focuses of three-dimensional pattern construction in detail. In terms of spatial reconstruction, it should reconstruct native culture and history while material culture was constructed, and reconstruct Qiang culture highland by depending on aborigines; in terms of cluster reconstruction, it should give support to large tourism enterprises and perfect tourism chain; in terms of ecological reconstruction, it should enhance construction and demonstration of "ecological protection pilot area of Qiang culture"; in terms of development reconstruction, it should realize coordinated unity between protection and development according to classification protection, characteristic protection and key protection, so as to form the virtuous circle of post-disaster recovery protection and sustainable development.
基金supported by the National Science and Technology Major Project of the Ministry of Science and Technology of China(No.2024ZD1200200).
文摘Oil-fired construction machinery(OCM)is a major source of urban air pollutants and CO_(2) emissions,and elec-trification is a crucial pathway for improving air quality and achieving China’s dual carbon goals;however,its feasibility has not been fully explored.This study uses data envelopment analysis and the analytic hierarchy process to establish a development potential index,covering technical efficiency,economic cost,application sce-narios,and charging time and range,with an empirical analysis conducted in Beijing.The findings indicated the high feasibility of replacing OCM with electric alternatives,especially within the low-power range.Based on 2023 registered coding dat1,it is projected that by 2030,electrification could reduce regional average con-centrations of CO,NO_(x),PM_(2.5) and VOCs by 12.2%to 56.4%and reduce CO_(2) by 11.7%to 56.9%.Owing to economic considerations,small-and medium-sized machinery are particularly feasible for electrification.Key recommendations include prioritizing the electrification of forklifts,lifting platforms,and small-sized machinery in high-emission areas,particularly in central urban districts.Policies such as carbon taxes,carbon markets,and performance grading systems are suggested to incentivize electrification,along with expanding high-emission restriction zones and improving energy infrastructure to support widespread electrification.
文摘To advance intelligent construction,standards must come first.The Ministry of Housing and Urban-Rural Development has issued the List for Replicable Experience and Practices for Developing Intelligent Construction four times successively and the Technical Guidelines for Intelligent Construction(Trial).
基金supported by the Foundation of Provincial Natural Science Research Project of Anhui Colleges(No.KJ2021ZD0047)the Anhui Provincial Natural Science Foundation(No.2008085J27)+1 种基金the China Postdoctoral Science Foundation(No.2019M652160)the Research Foundation of the Institute of Environment-friendly Materials and Occupational Health(Wuhu),Anhui University of Science and Technology(No.ALW2020YF05).
文摘The development of graphene-based composites with low density,robust absorption,wide bandwidth and thin thickness remained a great challenge in the field of electromagnetic(EM)absorption.In this work,nitrogen-doped reduced graphene oxide/hollow cobalt ferrite(NRGO/hollow CoFe_(2)O_(4))composite aerogels were constructed by a solvothermal and hydrothermal two-step route.Results demonstrated that the as-fabricated composite aerogels had the ultralow density and a unique three-dimensional(3D)network structure,and lots of hollow CoFe_(2)O_(4)microspheres were almost homogeneously distributed on the wrinkled surfaces of lamellar NRGO.Moreover,superior EM absorbing capacity could be achieved by modulating the ferrite structure,addition amounts of hollow CoFe_(2)O_(4)and thicknesses.It was noteworthy that the NRGO/hollow CoFe_(2)O_(4)composite aerogel with the addition amount of ferrite of 15.0 mg pos-sessed the minimum reflection loss of-44.7 dB and maximum absorption bandwidth of 5.2 GHz(from 12.6 to 17.8 GHz)at a very thin thickness of 1.8 mm and filling ratio of 15.0 wt.%.Furthermore,the possible EM attenuation mechanism had been proposed.The results of this work would be helpful for developing RGO-based 3D composites as lightweight,thin and highly efficient EM wave absorbers.
基金Supported by the Health Commission of Fuyang City,Anhui,China,No.FY2023-45Fuyang Municipal Science and Technology Bureau,Anhui,China,No.FK20245505+1 种基金Anhui Provincial Health Commission,No.AHWJ2023Baa20164Bengbu Medical University,No.2023byzd215.
文摘BACKGROUND Sigmoid colon cancer faces challenges due to anatomical diversity,including variable inferior mesenteric artery(IMA)branching and tumor localization complexities,which increase intraoperative risks.AIM To comprehensively evaluate the impact of three-dimensional(3D)visualization technology on enhancing surgical precision and safety,as well as optimizing perioperative outcomes in laparoscopic sigmoid cancer resection.METHODS A prospective cohort of 106 patients(January 2023 to December 2024)undergoing laparoscopic sigmoid cancer resection was divided into the 3D(n=55)group and the control(n=51)group.The 3D group underwent preoperative enhanced computed tomography reconstruction(3D Slicer 5.2.2&Mimics 19.0).3D reconstruction visualization navigation intraoperatively guided the following key steps:Tumor location,Toldt’s space dissection,IMA ligation level selection,regional lymph node dissection,and marginal artery preservation.Outcomes included operative parameters,lymph node yield,and recovery metrics.RESULTS The 3D group demonstrated a significantly shorter operative time(172.91±20.69 minutes vs 190.29±32.29 minutes;P=0.002),reduced blood loss(31.5±11.8 mL vs 44.1±23.4 mL,P=0.001),earlier postoperative flatus(2.23±0.54 days vs 2.53±0.61 days;P=0.013),shorter hospital length of stay(13.47±1.74 days vs 16.20±7.71 days;P=0.013),shorter postoperative length of stay(8.6±2.6 days vs 10.5±4.9 days;P=0.014),and earlier postoperative exhaust time(2.23±0.54 days vs 2.53±0.61 days;P=0.013).Furthermore,the 3D group exhibited a higher mean number of lymph nodes harvested(16.91±5.74 vs 14.45±5.66;P=0.030).CONCLUSION The 3D visualization technology effectively addresses sigmoid colon anatomical complexity through surgical navigation,improving procedural safety and efficiency.
基金Project(2012CB725301)supported by the National Basic Research Program of ChinaProject(201412015)supported by the National Special Fund for Surveying and Mapping Geographic Information Scientific Research in the Public Welfare of ChinaProject(212000168)supported by the Basic Survey-Mapping Program of National Administration of Surveying,Mapping and Geoinformation of China
文摘An automatic three-dimensional(3D) reconstruction method based on four-view stereo vision using checkerboard pattern is presented. Mismatches easily exist in traditional binocular stereo matching due to the repeatable or similar features of binocular images. In order to reduce the probability of mismatching and improve the measure precision, a four-camera measurement system which can add extra matching constraints and offer multiple measurements is applied in this work. Moreover, a series of different checkerboard patterns are projected onto the object to obtain dense feature points and remove mismatched points. Finally, the 3D model is generated by performing Delaunay triangulation and texture mapping on the point cloud obtained by four-view matching. This method was tested on the 3D reconstruction of a terracotta soldier sculpture and the Buddhas in the Mogao Grottoes. Their point clouds without mismatched points were obtained and less processing time was consumed in most cases relative to binocular matching. These good reconstructed models show the effectiveness of the method.
基金supported by The Program for Professor of Special Appointment(Eastern Scholar)at Shanghai Institutions of Higher Learning(No.TP2015002)the National Natural Science Foundation of China(No.51403099)
文摘Three-dimensional graphene/conducting polymer(3DGCP) composites have received significant attention in recent years due to their unique structures and promising applications in energy storage.With the structural diversity of graphene and π-functional conducting polymers via rich chemical routes,a number of 3DGCP composites with novel structures and attractive performance have been developed.Particularly,the hierarchical porosity,the interactions between graphene and conducting polymers as well as the their synergetic effects within 3DGCP composites can be well combined and elaborated by various synthetic methods,which made 3DGCP composites show unique electrochemical properties and significantly improved performance in energy storage fields compared to other graphenebased composites.In this short review,we present recent advances in 3DGCP composites in developing effective strategies to prepare 3DGCP composites and exploring them as a unique platform for supercapacitors with unprecedented performance.The challenges and future opportunities are also discussed for promotion of further study.
文摘A three-dimensional finite element simulation was carried out to investigate the effects of tunnel construction on nearby pile foundation.The displacement controlled model (DCM) was used to simulate the tunneling-induced volume loss effects.The numerical model was verified based on the results of a centrifuge test and a set of parametric studies was implemented based on this model.There is good agreement between the trend of the results of the centrifuge test and the present model.The results of parametric studies show that the tunnelling-induced pile internal force and deformation depend mainly on the pile?tunnel distance,the pile length to tunnel depth ratio and the volume loss.Two different zones are separated by a 45° line projected from the tunnel springline.Within the zone of influence,the pile is subjected to tensile force and large settlement;whereas outside the zone of influence,dragload and small settlement are induced.It is also established that the impact of tunnelling on a pile group is substantially smaller as compared with a single pile in the same location with the rear pile in a group,demonstrating a positive pile group effect.
文摘Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes(TMs).Methods: Middle ears were identified from 36 patients ranging 18-89 years of age with TM perforations who underwent tympanometry and temporal bone computed tomography(CT) between 2005 and 2015. MEVs calculated by both tympanometry and three-dimensional volume reconstruction(3DVR) were analyzed for agreement using Bland Altman plots. The differences between tympanometric and 3DVR MEV values for each given middle ear were characterized across MEV quartiles(1= smallest; 4= largest) and across increasing states of middle ear disease using Kruskale Wallis and Wilcoxon testing with Bonferroni correction.Results: Bland Altman plots demonstrated significant disagreement between MEV measurement techniques. Differences between tympanometric(T) and 3DVR MEV values were significantly greater with increasing average(i.e.(Tt3DVR)/2)) MEV per linear regression(p < 0.0001). Significance was demonstrated between fourth and first average MEV quartiles(p= 0.0024), fourth and second quartiles(p= 0.0024), third and first quartiles(p= 0.0048), and third and second quartiles(p= 0.048). Absolute MEV difference was not significantly different across varying states of middle ear disease(p= 0.44).Conclusion: Statistically and clinically significant disagreement was demonstrated between tympanometric and 3DVR MEV values. Studies that vary in MEV estimation techniques may be expected to demonstrate significantly different results. These preliminary results suggest that clinicians should endeavor to seek further confirmation when interpreting high tympanometric MEV values.
基金supported by the Norman Bethune B Program of Jilin University(No.2012216)the Science and Technology Development Program of Jilin Province(No.20100750),China
文摘The purpose of this study was to establish a method for measuring the knee valgus angle from the ana- tomical and mechanical axes on three-dimensional reconstruction imaging models, and to use this method for estimating an average knee valgus angle value for northern Chinese adults. Computed tomographic angiography data in DICOM format for 128 normal femurs from 64 adult subjects were chosen for analysis. After the femur images were subjected to three-dimensional reconstruction, the deepest point in the intercondylar notch (point A), the midpoint of the medullary cavity 20 cm above the knee-joint line (point B), and the landmark of the femoral head rotation center (point C) were identified on each three-dimensional model. The knee valgus angle was defined as the angle enclosed by the distal femoral anatomical axis (line AB) and the femoral mechanical axis (line AC). The average (mean+SD) of knee valgus angle for the 128 femurs was 6.20°±1.20° (range, 3.05° to 10.64°). Significant positive correlations were found between the knee valgus angles of the right and left sides and between the knee valgus angle and age. During total knee arthroplasty, choosing a valgus cut angle of approximately 6° may achieve a good result in reestablishing the natural mechanical alignment of the lower extremity for patients of northern Chinese ethnicity. Larger valgus cut angles should be chosen for older patients.
文摘Three-dimensional(3D)reconstruction of human organs has gained attention in recent years due to advances in the Internet and graphics processing units.In the coming years,most patient care will shift toward this new paradigm.However,development of fast and accurate 3D models from medical images or a set of medical scans remains a daunting task due to the number of pre-processing steps involved,most of which are dependent on human expertise.In this review,a survey of pre-processing steps was conducted,and reconstruction techniques for several organs in medical diagnosis were studied.Various methods and principles related to 3D reconstruction were highlighted.The usefulness of 3D reconstruction of organs in medical diagnosis was also highlighted.
文摘Summary: A three-dimensional (3D) graphic model of a single-chain Fv (scFv) which was derived from an anti-human placental acidic isoferritin (PAF) monoclonal antibody (MAb) was construct- ed by a homologous protein-predicting computer algorithm on Silicon graphic computer station. The structure, surface static electricity and hydrophobicity of scFv were investigated. Computer graphic modelling indicated that all regions of scFv including the linker, variable regions of the heavy (VH) and light (VL) chains were suitable. The VH region and the VL region were involved in composing the 'hydrophobic pocket'. The linker was drifted away VH and VL regions. The complementarity determining regions (CDRs) of VH and VL regions surrounded the 'hydrophobic pocket'. This study provides a theory basis for improving antibody affinity, investigating antibody structure and analyzing the functions of VH and VL regions in antibody activity.
文摘Objective:The aim of the study was to evaluate three-dimensional virtual models(3DVMs)usefulness in the intraoperative assistance of minimally-invasive partial nephrectomy in highly complex renal tumors.Methods:At our institution cT1-2N0M0 all renal masses with Preoperative Aspects and Dimensions Used for an Anatomical classification score≥10 treated with minimally-invasive partial nephrectomy were considered for the present study.For inclusion a baseline contrast-enhanced computed tomography in order to obtain 3DVMs,the baseline and postoperative serum creatinine as well as estimated glomerular filtration rate values were needed.These patients,in which 3DVMs were used to assist the surgeon in the planning and intraoperative guidance,were then compared with a control group of patients who underwent minimally-invasive partial nephrectomy with the same renal function assessments,but without 3DVMs.Multivariable logistic regression models were used to predict the margin,ischemia,and complication score achievement.Results:Overall,79 patients met the inclusion criteria and were compared with 143 complex renal masses without 3DVM assistance.The 3DVM group showed better postoperative outcomes in terms of baseline-weighted differential estimated glomerular filtration rate(-17.7%vs.-22.2%,p=0.03),postoperative complications(16.5%vs.23.1%,p=0.03),and major complications(Clavien Dindo>III,2.5%vs.5.6%,p=0.03).At multivariable logistic regression 3DVM assistance independently predicted higher rates of successful partial nephrectomy(odds ratio:1.42,p=0.03).Conclusion:3DVMs represent a useful tool to plan a tailored surgical approach in case of surgically complex masses.They can be used in different ways,matching the surgeon's needs from the planning phase to the demolitive and reconstructive phase,leading towards maximum safety and efficacy outcomes.