期刊文献+
共找到1,468篇文章
< 1 2 74 >
每页显示 20 50 100
Three-dimensional Copula-based Assessment of Meteorological Drought Characteristics and Driving Mechanisms in Haihe River Basin, China
1
作者 XUE Jianwen ZHAO Qiang +4 位作者 ZHANG Yuhu CHEN Yali WANG Xuan DOU Xiangzhou LI Xiumei 《Chinese Geographical Science》 2025年第3期545-563,共19页
Owing to the complexity of droughts,detailed assessments of drought events have become a key issue in water resource management and planning.In this study,three-dimensional copula models at Standard Precipitation Evap... Owing to the complexity of droughts,detailed assessments of drought events have become a key issue in water resource management and planning.In this study,three-dimensional copula models at Standard Precipitation Evapotranspiration Index(SPEI)-1,SPEI-3,SPEI-6,and SPEI-12 were used to assess drought risks in the Haihe River Basin(HRB)of China from 1961–2020.Drought duration,severity,and peak,as indicated by SPEI,were extracted based on run theory and fitted with suitable marginal distributions.The difference between the joint return period(Tor)and the co-occurrence return period(Tand)could explain the intrinsic correlation between drought characteristics.The smaller the difference,the stronger the correlation.The results showed that droughts in the north-western region of the HRB were characterized by high peak,intense severity,and long duration.In contrast,the eastern region exhibited a higher frequency of drought occurrence.Furthermore,the decreasing trend in precipitation dominated droughts,and topography of the northwest region creates the features of low annual precipitation with more days of precipitation.The drought events in the HRB were influenced by the phase shift between El Niño and La Niña.There was a strong negative phase coupling between SPEI-12 and Niño3.4(R^(2)≥0.77).The transition from La Niña to El Niño was responsible for severe droughts in the HRB.The El Niño-Southern Oscillation could predict droughts with lag times of 0.15–4.35 mon in mountainous areas. 展开更多
关键词 three-dimensional copula DROUGHT Standard Precipitation Evapotranspiration Index(SPEI) El Niño-Southern Oscillation TOPOGRAPHY Haihe River Basin China
在线阅读 下载PDF
基于Copula函数的上海地区雨洪潮遭遇概率研究
2
作者 王文鹏 袁亚玲 +4 位作者 赵庚润 刘敏 李琪 陈元芳 黄琴 《长江流域资源与环境》 北大核心 2026年第2期524-535,共12页
江河交汇之处的城市普遍遭受本地暴雨叠加上游洪水及外潮顶托威胁,探明雨洪潮遭遇规律,是城市防洪安全设计的必要条件。采用Copula函数理论,分析上海地区遭暴雨、太湖来洪、吴淞口高潮顶托的联合分布律,估计最可能雨洪潮组合情景。结果... 江河交汇之处的城市普遍遭受本地暴雨叠加上游洪水及外潮顶托威胁,探明雨洪潮遭遇规律,是城市防洪安全设计的必要条件。采用Copula函数理论,分析上海地区遭暴雨、太湖来洪、吴淞口高潮顶托的联合分布律,估计最可能雨洪潮组合情景。结果表明:Frank型Copula联结P-III型边际分布是描述雨洪潮遭遇分布律的最优模式;按联合概率计,雨洪潮各按千年一遇设防只相当于联合防御重现期333年一遇;按同现概率计,变量独立条件下明显高估了同现重现期,考虑变量相关性2000年以来严重威胁上海的菲特、麦莎、烟花台风,雨洪潮同现重现期依次降至1200、131、69年一遇,仍可能再次发生;暴雨遭遇洪潮组合的条件分布律呈现暴雨愈大洪潮愈高的特点。结果可为上海地区防洪安全设计提供参考,提高对雨洪潮随机并发致洪的防御能力。 展开更多
关键词 联合分布 三维copula函数 联合概率 同现概率 条件最可能组合
原文传递
Assessment of Left Atrial Function by Full Volume Real-time Three-dimensional Echocardiography and Left Atrial Tracking in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models 被引量:9
3
作者 Yang Wang Lin Gao +1 位作者 Jian-bai Li Chao Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2013年第3期152-158,共7页
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tra... Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT). 展开更多
关键词 essential hypertension left atrial function three-dimensional echocardiography left atrial tracking
暂未订购
Anorectal dysfunction in patients with mid-low rectal cancer after surgery: A pilot study with three-dimensional high-resolution manometry 被引量:5
4
作者 Yan-Na Pi Yi Xiao +3 位作者 Zhi-Feng Wang Guo-Le Lin Hui-Zhong Qiu Xiu-Cai Fang 《World Journal of Clinical Cases》 SCIE 2022年第12期3754-3763,共10页
BACKGROUND The quality of life in patients who develop low anterior resection syndrome(LARS)after surgery for mid-low rectal cancer is seriously impaired.The underlying pathophysiological mechanism of LARS has not bee... BACKGROUND The quality of life in patients who develop low anterior resection syndrome(LARS)after surgery for mid-low rectal cancer is seriously impaired.The underlying pathophysiological mechanism of LARS has not been fully investigated.AIM To assess anorectal function of mid-low rectal cancer patients developing LARS perioperatively.METHODS Patients diagnosed with mid-low rectal cancer were included.The LARS score was used to evaluate defecation symptoms 3 and 6 mo after anterior resection or a stoma reversal procedure.Anorectal functions were assessed by threedimensional high resolution anorectal manometry preoperatively and 3-6 mo after surgery.RESULTS The study population consisted of 24 patients.The total LARS score was decreased at 6 mo compared with 3 mo after surgery(P<0.05),but 58.3%(14/24)lasted as major LARS at 6 mo after surgery.The length of the high-pressure zone of the anal sphincter was significantly shorter,the mean resting pressure and maximal squeeze pressure of the anus were significantly lower than those before surgery in allpatients (P < 0.05), especially in the neoadjuvant therapy group after surgery (n = 18). The focalpressure defects of the anal canal were detected in 70.8% of patients, and those patients had higherLARS scores at 3 mo postoperatively than those without focal pressure defects (P < 0.05). Spasticperistaltic contractions from the new rectum to anus were detected in 45.8% of patients, whichwere associated with a higher LARS score at 3 mo postoperatively (P < 0.05).CONCLUSIONThe LARS score decreases over time after surgery in the majority of patients with mid-low rectalcancer. Anorectal dysfunctions, especially focal pressure defects of the anal canal and spasticperistaltic contractions from the new rectum to anus postoperatively, might be the majorpathophysiological mechanisms of LARS. 展开更多
关键词 Low anterior resection syndrome Anorectal function three-dimensional high-resolution manometry Rectal cancer
暂未订购
A Three-Dimensional Size-Dependent Layered Model for Simply-Supported and Functionally Graded Magnetoelectroelastic Plates 被引量:3
5
作者 Junhong Guo Jiangyi Chen Ernian Pan 《Acta Mechanica Solida Sinica》 SCIE EI CSCD 2018年第5期652-671,共20页
A three-dimensional size-dependent layered model for simply-supported and func- tionally graded magnetoelectroelastic plates is presented based on the modified couple-stress theory. The functionally graded material is... A three-dimensional size-dependent layered model for simply-supported and func- tionally graded magnetoelectroelastic plates is presented based on the modified couple-stress theory. The functionally graded material is assumed to be exponential in the thickness direc- tion of the plate. The final governing equations are reduced to an eigensystem by expressing the extended displacements in terms of two-dimensional Fourier series. Using the propagator matrix method, the exact solutions of the magnetic, electric and mechanical fields of sandwich nanoplates with couple-stress effect and under the surface loads are derived. Numerical examples for two functionally graded sandwich plates made of piezoelectric BaTiO3 and magnetostrictive CoFe2O4 materials are presented to demonstrate the effect of the functional gradient factor and material length-scale parameter on the induced fields. The exact solutions presented in this work can also serve as benchmarks to various numerical methods for analyzing the size-dependent features in layered systems. 展开更多
关键词 functionally graded MAGNETOELECTROELASTIC Modified couple stress Layered plate three-dimensional solution
原文传递
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
6
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
暂未订购
THREE-DIMENSIONAL ANALYSIS OF FUNCTIONALLY GRADED PLATE BASED ON THE HAAR WAVELET METHOD 被引量:2
7
作者 Zhang Chun Zhong Zheng 《Acta Mechanica Solida Sinica》 SCIE EI 2007年第2期95-102,共8页
A three-dimensional analysis of a simply-supported functionally graded rectangular plate with an arbitrary distribution of material properties is made using a simple and effective method based on the Haar wavelet. Wit... A three-dimensional analysis of a simply-supported functionally graded rectangular plate with an arbitrary distribution of material properties is made using a simple and effective method based on the Haar wavelet. With good features in treating singularities, Haar series solution converges rapidly for arbitrary distributions, especially for the case where the material properties change rapidly in some regions. Through numerical examples the influences of the ratio of material constants on the top and bottom surfaces and different material gradient distributions on the structural response of the plate to mechanical stimuli are studied. 展开更多
关键词 functionally graded material rectangular plate Haar wavelet three-dimensional analysis
在线阅读 下载PDF
Three-dimensional visualization of the functional fascicular groups of a long-segment peripheral nerve 被引量:3
8
作者 Jian Qi Wei-Ya Wang +7 位作者 Ying-Chun Zhong Jia-Ming Zhou Peng Luo Ping Tang Cai-Feng He Shuang Zhu Xiao-Lin Liu Yi Zhang 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第8期1465-1470,共6页
The three-dimensional(3D) visualization of the functional bundles in the peripheral nerve provides direct and detailed intraneural spatial information. It is useful for selecting suitable surgical methods to repair ... The three-dimensional(3D) visualization of the functional bundles in the peripheral nerve provides direct and detailed intraneural spatial information. It is useful for selecting suitable surgical methods to repair nerve defects and in optimizing the construction of tissue-engineered nerve grafts. However, there remain major technical hurdles in obtaining, registering and interpreting 2D images, as well as in establishing 3D models. Moreover, the 3D models are plagued by poor accuracy and lack of detail and cannot completely reflect the stereoscopic microstructure inside the nerve. To explore and help resolve these key technical problems of 3D reconstruction, in the present study, we designed a novel method based on re-imaging techniques and computer image layer processing technology. A 20-cm ulnar nerve segment from the upper arm of a fresh adult cadaver was used for acetylcholinesterase(ACh E) staining. Then, 2D panoramic images were obtained before and after ACh E staining under the stereomicroscope. Using layer processing techniques in Photoshop, a space transformation method was used to fulfill automatic registration. The contours were outlined, and the 3D rendering of functional fascicular groups in the long-segment ulnar nerve was performed with Amira 4.1 software. The re-imaging technique based on layer processing in Photoshop produced an image that was detailed and accurate. The merging of images was accurate, and the whole procedure was simple and fast. The least square support vector machine was accurate, with an error rate of only 8.25%. The 3D reconstruction directly revealed changes in the fusion of different nerve functional fascicular groups. In conclusion. The technique is fast with satisfactory visual reconstruction. 展开更多
关键词 nerve regeneration peripheral nerve ulnar nerve three-dimensional reconstruction functional fascicular group REGISTRATION segmentation locating spots auto-registration ACETYLCHOLINESTERASE neural regeneration
暂未订购
Three-dimensionally ordered macroporous cross-linked polystyrene incorporating functional group via hydrophilic spacer arm 被引量:1
9
作者 Li Xia Yuan Xiao Mei Wang Xu Zhang Pan Ge Liu Wei Dong Yan 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第12期1493-1496,共4页
A versatile and effective method for incorporating functional groups on the pore wall of three-dimensionally ordered macroporous cross-linked polystyrene(3DOM CLPS) by hydrophilic spacer arm has been investigated.Th... A versatile and effective method for incorporating functional groups on the pore wall of three-dimensionally ordered macroporous cross-linked polystyrene(3DOM CLPS) by hydrophilic spacer arm has been investigated.The 3DOM CLPS with pore size 865 nm was prepared by sacrifice template method.The hydrophilic spacer arm(polyethylene glycol,molecular weight is 600) was grafted to the 3DOM CLPS via nucleophilic substitution reaction.The other side of active hydroxyl can be further converted into a lot of other functional groups.In this report,the chelating ligand 2-mercaptobenzothiazole(MBZ) group was introduced on the end of the PGE chain to evidence the versatile functionalization approach.The functionalized ordered macroporous materials were characterized by FT-IR,element analyzer,SEM.The results reveal that the pores were successfully bonded with 2-mercaptobenzothiazole groups via hydrophilic spacer arms and the original morphology of ordered macroporous materials were remained after functionalization.The MBZ group density is 0.052 mmol/m^2.The functionalized 3DOM CLPS are expected to application as heavy metal ions adsorbent. 展开更多
关键词 three-dimensionally ordered macroporous polymer functionALIZATION Hydrophilic space arm Heterocyclic functional group
在线阅读 下载PDF
Simulation of three-dimensional tension-induced cracks based on cracking potential function-incorporated extended finite element method 被引量:1
10
作者 WANG Xiang-nan YU Peng +4 位作者 ZHANG Xiang-tao YU Jia-lin HAO Qing-shuo LI Quan-ming YU Yu-zhen 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第1期235-246,共12页
In the finite element method,the numerical simulation of three-dimensional crack propagation is relatively rare,and it is often realized by commercial programs.In addition to the geometric complexity,the determination... In the finite element method,the numerical simulation of three-dimensional crack propagation is relatively rare,and it is often realized by commercial programs.In addition to the geometric complexity,the determination of the cracking direction constitutes a great challenge.In most cases,the local stress state provides the fundamental criterion to judge the presence of cracks and the direction of crack propagation.However,in the case of three-dimensional analysis,the coordination relationship between grid elements due to occurrence of cracks becomes a difficult problem for this method.In this paper,based on the extended finite element method,the stress-related function field is introduced into the calculation domain,and then the boundary value problem of the function is solved.Subsequently,the envelope surface of all propagation directions can be obtained at one time.At last,the possible surface can be selected as the direction of crack development.Based on the aforementioned procedure,such method greatly reduces the programming complexity of tracking the crack propagation.As a suitable method for simulating tension-induced failure,it can simulate multiple cracks simultaneously. 展开更多
关键词 extended finite element method CRACK three-dimensional calculation cracking potential function tensile failure
在线阅读 下载PDF
基于Copula的长江流域复合干热事件演变特征分析
11
作者 毛雅雯 刘柯莹 敖天其 《人民长江》 北大核心 2026年第1期73-81,共9页
为揭示长江流域复合干热事件的时空演变特征,利用1961~2022年长江流域月降水和月气温观测资料,基于标准化降水指数(SPI)和标准化温度指数(STI)分析了复合干热事件的发生频率和发生面积变化特征;在此基础上,利用Copula函数构建高温和干... 为揭示长江流域复合干热事件的时空演变特征,利用1961~2022年长江流域月降水和月气温观测资料,基于标准化降水指数(SPI)和标准化温度指数(STI)分析了复合干热事件的发生频率和发生面积变化特征;在此基础上,利用Copula函数构建高温和干旱的二维联合分布函数,计算不同强度阈值下的联合重现期。结果表明:1961~2022年长江流域中下游地区为复合干热事件的高发区;1992~2022年相比1961~1991年,长江流域上、中、下游的发生频率均呈现增加趋势,中下游区域增长较显著;轻度、中度复合干热事件发生面积增长速率分别为每10 a增长2%和1%;长江流域内轻度复合干热事件较为频繁,平均重现期在0~26 a,中度以上复合干热事件重现期在9~92 a,上游平均重现期略高于中下游;2006、2013、2019年和2022年为复合干热事件典型年,联合重现期分别为181,335,109 a和401 a。研究成果可为深入认识长江流域复合干热事件的演变规律提供科学支撑。 展开更多
关键词 复合干热事件 重现期 SPI STI copula函数 长江流域
在线阅读 下载PDF
Safety and efficacy of three-dimensional reconstruction technologyassisted percutaneous transhepatic biliary drainage:A metaanalysis
12
作者 Ze-Hui Chen Li-Juan Zhang +4 位作者 Zhi-Xin Lin Shu-Xiang Lin Zheng-Fu Song Ze-Jian Wu Wei Lin 《World Journal of Gastrointestinal Surgery》 2025年第9期367-380,共14页
BACKGROUND Percutaneous transhepatic biliary drainage(PTBD)is one of the primary clinical treatment options for patients with obstructive jaundice.In recent years,PTBD assisted by three-dimensional(3D)reconstruction t... BACKGROUND Percutaneous transhepatic biliary drainage(PTBD)is one of the primary clinical treatment options for patients with obstructive jaundice.In recent years,PTBD assisted by three-dimensional(3D)reconstruction technology has been widely implemented,but its advantages over traditional methods remains inconclusive.Thus,a discussion is warranted.AIM To explore the safety and efficacy of 3D reconstruction technology-assisted PTBD.METHODS We systematically searched the databases including the Cochrane Library,PubMed,EMBASE,Web of Science and China National Knowledge Infrastructure.The search period extended from the establishment of each database to November,2024.We screened the literature according to predefined inclusion and exclusion criteria,assessed the quality of the studies,and extracted data.Meta-analysis was performed using Revman 5.4.1 software.RESULTS A total of 15 studies were included,involving 1434 patients.The results of the meta-analysis showed that compared with the traditional group,the overall post-operative complications rate in the 3D reconstruction technology group was significantly lower[odds ratio=0.25;95%confidence interval(CI):0.17-0.36,P<0.00001].The overall puncture success rate in the 3D reconstruction group was better than those in the traditional group(odds ratio=3.61;95%CI:1.98-6.55,P<0.0001).However,there was no significant difference between the two groups in the reduction levels of postoperative total bilirubin(mean difference=-1.38;95%CI:-3.29 to 0.53,P=0.16).Subgroup analysis were conducted on the surgery time according to guidance stages of the 3D reconstruction,3D reconstruction imaging modalities,and types of studies.The results were stable,with no significant changes observed.CONCLUSION 3D reconstruction technology significantly improves the puncture success rate and safety of PTBD.However,it has no significant advantage in bile drainage effectiveness.Continued research is warranted to further explore its clinical value and optimize its application. 展开更多
关键词 three-dimensional reconstruction technology Percutaneous transhepatic biliary drainage Obstructive jaundice COMPLICATIONS Liver function
暂未订购
Superior decomposition of xenobiotic RB5 dye using three-dimensional electrochemical treatment:Response surface methodology modelling,artificial intelligence,and machine learning-based optimisation approaches
13
作者 Voravich Ganthavee Antoine P.Trzcinski 《Water Science and Engineering》 2025年第1期1-10,共10页
The highly efficient electrochemical treatment technology for dye-polluted wastewater is one of hot research topics in industrial wastewater treatment.This study reported a three-dimensional electrochemical treatment ... The highly efficient electrochemical treatment technology for dye-polluted wastewater is one of hot research topics in industrial wastewater treatment.This study reported a three-dimensional electrochemical treatment process integrating graphite intercalation compound(GIC)adsorption,direct anodic oxidation,and·OH oxidation for decolourising Reactive Black 5(RB5)from aqueous solutions.The electrochemical process was optimised using the novel progressive central composite design-response surface methodology(CCD-NPRSM),hybrid artificial neural network-extreme gradient boosting(hybrid ANN-XGBoost),and classification and regression trees(CART).CCD-NPRSM and hybrid ANN-XGBoost were employed to minimise errors in evaluating the electrochemical process involving three manipulated operational parameters:current density,electrolysis(treatment)time,and initial dye concentration.The optimised decolourisation efficiencies were 99.30%,96.63%,and 99.14%for CCD-NPRSM,hybrid ANN-XGBoost,and CART,respectively,compared to the 98.46%RB5 removal rate observed experimentally under optimum conditions:approximately 20 mA/cm^(2) of current density,20 min of electrolysis time,and 65 mg/L of RB5.The optimised mineralisation efficiencies ranged between 89%and 92%for different models based on total organic carbon(TOC).Experimental studies confirmed that the predictive efficiency of optimised models ranked in the descending order of hybrid ANN-XGBoost,CCD-NPRSM,and CART.Model validation using analysis of variance(ANOVA)revealed that hybrid ANN-XGBoost had a mean squared error(MSE)and a coefficient of determination(R^(2))of approximately 0.014 and 0.998,respectively,for the RB5 removal efficiency,outperforming CCD-NPRSM with MSE and R^(2) of 0.518 and 0.998,respectively.Overall,the hybrid ANN-XGBoost approach is the most feasible technique for assessing the electrochemical treatment efficiency in RB5 dye wastewater decolourisation. 展开更多
关键词 three-dimensional electrochemical treatment Dye-polluted wastewater Artificial intelligence Machine learning Optimisation Analysis of variance Error function analysis
在线阅读 下载PDF
基于模糊聚类与Copula的场景特征自适应风速预测模型
14
作者 王永真 唐豪 +3 位作者 韩特 李嘉宇 韩恺 冶兆年 《全球能源互联网》 北大核心 2026年第1期24-35,共12页
针对多变量风速预测中存在的特征选择复杂、计算效率低及模型泛化能力不足等问题,提出一种融合场景划分与最优Copula选择的自适应风速预测模型。构建了“场景聚类-动态变量选择-滚动预测”的三阶段协同机制:首先,采用模糊C均值聚类算法... 针对多变量风速预测中存在的特征选择复杂、计算效率低及模型泛化能力不足等问题,提出一种融合场景划分与最优Copula选择的自适应风速预测模型。构建了“场景聚类-动态变量选择-滚动预测”的三阶段协同机制:首先,采用模糊C均值聚类算法将多维气象数据划分为具有相似特征的天气场景;其次,运用Copula函数构建多变量相关性模型,依欧氏距离筛选最优Copula函数,结合综合相关系数,实现场景自适应的动态变量选择;最终,设计分场景LSTM预测模型与实时数据滚动更新策略,通过动态匹配场景特征与预测模型提升预测精度。以欧洲某地区公开的天气数据进行验证表明,所提出的方法模型在风速预测准确性上优于单一场景预测模型。具体表现为,均方根误差降低3.6%,标准化误差降低5.2%,平均绝对百分比误差降低4.2%,决定系数提高4.5%。 展开更多
关键词 风速预测 长短期记忆网络(LSTM) copula函数场景自适应 模糊C均值聚类
在线阅读 下载PDF
Three-dimensional elasticity solutions for bending of generally supported thick functionally graded plates
15
作者 张鹤 蒋吉清 张治成 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2014年第11期1467-1478,共12页
Three-dimensional elasticity solutions for static bending of thick functionally graded plates are presented using a hybrid semi-analytical approach-the state-space based differential quadrature method (SSDQM). The p... Three-dimensional elasticity solutions for static bending of thick functionally graded plates are presented using a hybrid semi-analytical approach-the state-space based differential quadrature method (SSDQM). The plate is generally supported at four edges for which the two-way differential quadrature method is used to solve the in-plane variations of the stress and displacement fields numerically. An approximate laminate model (ALM) is exploited to reduce the inhomogeneous plate into a multi-layered laminate, thus applying the state space method to solve analytically in the thickness direction. Both the convergence properties of SSDQM and ALM are examined. The SSDQM is validated by comparing the numerical results with the exact solutions reported in the literature. As an example, the Mori-Tanaka model is used to predict the effective bulk and shear moduli. Effects of gradient index and aspect ratios on the bending behavior of functionally graded thick plates are investigated. 展开更多
关键词 functionally grade material thick plate three-dimensional solution semianalytical approach
在线阅读 下载PDF
基于Copula函数的永定河流域天然径流变异特征研究
16
作者 牛凯杰 姜守政 +2 位作者 刘庚 张鹏飞 李晓璐 《水利发展研究》 2026年第2期81-92,共12页
为探究20世纪70年代以来永定河天然径流衰减的根本原因,诊断了永定河流域典型水文站天然径流序列变异点,采用Copula函数研究永定河流域天然径流与降水—径流响应结构关系变异特征,并讨论导致其变异的主要原因。研究表明:1956—2016年永... 为探究20世纪70年代以来永定河天然径流衰减的根本原因,诊断了永定河流域典型水文站天然径流序列变异点,采用Copula函数研究永定河流域天然径流与降水—径流响应结构关系变异特征,并讨论导致其变异的主要原因。研究表明:1956—2016年永定河干支流天然径流序列具有显著衰减趋势性与突变性;降水—径流相关性结构在1983年前后的边缘分布、联合分布和条件分布概率变化呈显著调整,降水与天然径流的联合概率和分布区间在变化期内明显变小,满足相同产流需要的降水量在变化期内显著增加,表明20世纪80年代后永定河流域水文响应关系和产流机制已发生根本性变化;退耕还林、城镇化以及地下水开采可能是永定河天然径流及水文响应关系变异的原因。 展开更多
关键词 天然径流 变异 copula函数 水文响应关系 永定河流域
在线阅读 下载PDF
Balanced Functional Maps for Three-Dimensional Non-Rigid Shape Registration
17
作者 Xu-Peng Wang Hang Lei +1 位作者 Yan Liu Nan Sang 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第4期369-378,共10页
Three-dimensional(3D)shape registration is a challenging problem,especially for shapes under non-rigid transformations.In this paper,a 3D non-rigid shape registration method is proposed,called balanced functional maps... Three-dimensional(3D)shape registration is a challenging problem,especially for shapes under non-rigid transformations.In this paper,a 3D non-rigid shape registration method is proposed,called balanced functional maps(BFM).The BFM algorithm generalizes the point-based correspondence to functions.By choosing the Laplace-Beltrami eigenfunctions as the function basis,the transformations between shapes can be represented by the functional map(FM)matrix.In addition,many constraints on shape registration,such as the feature descriptor,keypoint,and salient region correspondence,can be formulated linearly using the matrix.By bi-directionally searching for the nearest neighbors of points’indicator functions in the function space,the point-based correspondence can be derived from FMs.We conducted several experiments on the Topology and Orchestration Specification for Cloud Applications(TOSCA)dataset and the Shape Completion and Animation of People(SCAPE)dataset.Experimental results show that the proposed BFM algorithm is effective and has superior performance than the state-of-the-art methods on both datasets. 展开更多
关键词 functional map(FM) Laplace-Beltrami operator shape registration three-dimensional(3D)non-rigid shape.
在线阅读 下载PDF
Preliminary Clinical Study of Real-time Three-dimensional Echo-cardiographic Volume-time Curve in Evaluating Left Ventricular Diastolic Function
18
作者 费洪文 何亚乐 +3 位作者 侯跃双 许燕 黄新胜 冯碧霞 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2007年第4期475-478,共4页
The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfuncti... The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfunction was defined by E'〈A' in pulse-wave tissue Doppler for inter-ventricular septal (IVS) of mitral annulus. In 24 patients with LV diastolic dysfunction, including 12 patients with delayed relaxation (delayed relaxation group) and 12 patients with pseudo-normal function (pseudo-normal group) and 24 normal volunteers (control group), data of full-volume image were acquired by real-time three-dimensional echocardiography and subjected to volume-time curve analysis. EDV (end-diastolic volume), ESV (end-systolic volume), LVEF (left ventricular ejection fraction), PER (peak ejection rate), PFR (peak filling rate) from RT3DE were examined in the three groups. Compared to the control group, PFR (diastolic filling index of RT3DE) was significantly reduced in the delayed relaxation group and pseudo-normal group (P〈0.05). There were no significant differences in EDV, ESV, LVEE PER (P〉0.05). It is concluded that PFR, as a diastolic filling index of RT3DE, can reflect the early diastolic function and serve as a new non-invasive, quick and accurate tool for clinical assessment of LV diastolic function. 展开更多
关键词 real-time three-dimensional echocardiography left ventricular diastolic function volume-time curve
暂未订购
Correlation analysis of real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis
19
作者 Lin Li Hong-Ying Zhu He-Juan Du 《Journal of Hainan Medical University》 2019年第12期67-70,共4页
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method... Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated. 展开更多
关键词 REAL-TIME three-dimensional ultrasound CIRRHOSIS Left VENTRICULAR function Portal HEMODYNAMICS Liver function
暂未订购
Value of myocardial function in children with Kawasaki disease by two-dimensional and three-dimensional ultrasound speckle tracking
20
作者 Ya-Mei Shen Tao-Min Bai +4 位作者 Xue-Mei Zhang Chun-Miao Kang Xiao-Ni Chang Yan-Hua Gao Xiao-Hua Yan 《Journal of Hainan Medical University》 2019年第21期58-61,共4页
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met... Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease. 展开更多
关键词 KAWASAKI disease TWO-DIMENSIONAL ULTRASOUND SPECKLE TRACKING three-dimensional ULTRASOUND SPECKLE TRACKING myocardial function left ventricular systolic function
暂未订购
上一页 1 2 74 下一页 到第
使用帮助 返回顶部