期刊文献+
共找到1,280篇文章
< 1 2 64 >
每页显示 20 50 100
Response optimization of a three-axis sensitive SERF magnetometer for closed-loop operation 被引量:1
1
作者 周原锐 孙永泽 +3 位作者 汪茜茜 秦佳男 张雪 王言章 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期291-297,共7页
Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of the... Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly. 展开更多
关键词 triaxial-vectorial magnetic field measurement spin-exchange relaxation free atomic magnetometer
原文传递
Comprehensive analysis of noise in Macao Science Satellite-1 vector magnetometer data 被引量:1
2
作者 SiShan Song Fan Yin +4 位作者 Qin Yan Hermann Lühr Chao Xiong Yi Jiang PengFei Liu 《Earth and Planetary Physics》 2025年第3期532-540,共9页
The Macao Science Satellite-1(known as MSS-1)is the first scientific exploration satellite that was designed to measure the Earth's low latitude magnetic field at high resolution and with high precision by collect... The Macao Science Satellite-1(known as MSS-1)is the first scientific exploration satellite that was designed to measure the Earth's low latitude magnetic field at high resolution and with high precision by collecting data in a near-equatorial orbit.Magnetic field data from MSS-1's onboard Vector Fluxgate Magnetometer(VFM),collected at a sample rate of 50 Hz,allows us to detect and investigate sources of magnetic data contamination,from DC to relevant Nyquist frequency.Here we report two types of artificial disturbances in the VFM data.One is V-shaped events concentrated at night,with frequencies sweeping from the Nyquist frequency down to zero and back up.The other is 5-Hz events(ones that exhibit a distinct 5 Hz spectrum peak);these events are always accompanied by intervals of spiky signals,and are clearly related to the attitude control of the satellite.Our analyses show that VFM noise levels in daytime are systematically lower than in nighttime.The daily average noise levels exhibit a period of about 52 days.The V-shaped events are strongly correlated with higher VFM noise levels. 展开更多
关键词 Macao Science Satellite-1 Vector Fluxgate magnetometer artificial disturbances noise features
在线阅读 下载PDF
In-flight calibration of the fluxgate magnetometer on Macao Science Satellite-1 被引量:1
3
作者 YiXin Qiu Ying Zhang +8 位作者 YaSong Ge AiMin Du ShuQuan Sun Lin Zhao Hao Luo Lei Wang Lin Tian Zhi Li Xiao Feng 《Earth and Planetary Physics》 2025年第3期511-520,共10页
High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science ... High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment. 展开更多
关键词 Macao Science Satellite-1(MSS-1) in-flight calibration Euler angles estimation geomagnetic fields model fluxgate magnetometer
在线阅读 下载PDF
Experimental research on three-axis control of flying-wing aircraft based on active flow control
4
作者 Buxian XU Lihao FENG 《Chinese Journal of Aeronautics》 2025年第8期169-186,共18页
The flying-wing aircraft has excellent aerodynamic efficiency and stealth performance.However,due to the lack of tails,the flying-wing aircraft has a serious attitude control problem.In this paper,the effective flow c... The flying-wing aircraft has excellent aerodynamic efficiency and stealth performance.However,due to the lack of tails,the flying-wing aircraft has a serious attitude control problem.In this paper,the effective flow control strategy of three-axis control is proposed by using continuous jets for a flapless flying-wing aircraft.The wind tunnel test of two kinds of flying-wing models,namely one flow control model and one mechanical control model,is conducted,and the control effect is analyzed and compared.By simultaneous blowing of the circulation control actuators inboard and differential blowing of the circulation control actuators outboard,the pitch and roll controls are achieved,respectively.It also has an effective control effect at very large angles of attack where the conventional control surface fails.A linear relationship is found between the increment of the controlled aerodynamic force/moment coefficient and the momentum coefficient for circulation control actuators.Moreover,to resolve the difficulty in yaw control,a novel wingtip jet is proposed based on the concept of the all-moving tip and compared with apex jet and circulation control jet.It is found that the wingtip jet is the most efficient actuator,followed by the simultaneous-blowing circulation control jet.Therefore,based on the research above,two optimized fluidic control configurations are proposed.One employs circulation control jet and wingtip jet,and the other is completely dependent on circulation control jet.Finally,the flow control mechanism of circulation control is discussed.Circulation control significantly accelerates the flow on the upper surface of the airfoil in attached flow and reduces the flow separation region in separated flow,leading to aerodynamic performance improvement.These results provide an important theoretic basis for the flapless flight control of flying-wing aircraft. 展开更多
关键词 Circulation control three-axis control Flying wing Flapless aircraft Wind tunnel test
原文传递
Femtotesla atomic magnetometer for zero-and ultralow-field nuclear magnetic resonance
5
作者 Taizhou Hong Yuanhong Wang +3 位作者 Zhenhan Shao Qing Li Min Jiang Xinhua Peng 《Magnetic Resonance Letters》 2025年第3期1-9,共9页
Zero-and ultralow-field nuclear magnetic resonance(ZULF NMR)has experienced rapid development and provides an excellent tool for diverse research fields ranging from materials science and quantum information processin... Zero-and ultralow-field nuclear magnetic resonance(ZULF NMR)has experienced rapid development and provides an excellent tool for diverse research fields ranging from materials science and quantum information processing to fundamental physics.The detection of ZULF NMR signals in samples with natural abundance remains a challenging endeavor,due to the limited sensitivity of NMR detectors and thermal polarization.In this work,we demonstrate a femtotesla(fT)Potassium spin-exchange relaxation-free(SERF)magnetometer designed for ZULF NMR detection.A Potassium vapor cell with high buffer gas pressure and high atomic number density is used in the magnetometer.With absorption spectroscopy and SERF effect,the key parameters of the vapor cell are characterized and applied to optimize the magnetometer sensitivity.To combine our SERF magnetometer and ZULF NMR detection,a custom-made vacuum chamber is employed to keep NMR sample close to the magnetometer cell and protect the sample from undesired heating effects.Gradiometric measurement is performed to greatly reduce the magnetic noise.With the phase calibration applied,the gradiometric measurement achieves 7-fold enhancement in magnetic-field sensitivity compared to the single channel and has a magnetic noise floor of 1.2 fT/Hz^(1/2).Our SERF magnetometer exhibits high sensitivity and is promising to realize ZULF NMR detection of samples with natural abundance. 展开更多
关键词 Atomic magnetometer Zero-to ultralow-field nuclear magnetic resonance Spin-exchange relaxation free effect Gradient measurement
在线阅读 下载PDF
SINS/DGPS/Magnetometer组合导航研究
6
作者 王直 张军 《航天控制》 CSCD 北大核心 2006年第3期21-24,34,共5页
本文针对SINS/DGPS/Magnetometer全组合系统进行了研究,建立了相应的误差模型和系统观测模型。应用扩展卡尔曼滤波算法将GPS测量方程和SINS动态线性化,进行SINS验前状态估计及其误差协方差时间更新。仿真结果表明:本文提出的组合导航系... 本文针对SINS/DGPS/Magnetometer全组合系统进行了研究,建立了相应的误差模型和系统观测模型。应用扩展卡尔曼滤波算法将GPS测量方程和SINS动态线性化,进行SINS验前状态估计及其误差协方差时间更新。仿真结果表明:本文提出的组合导航系统能够给出载体的高精度姿态信息,位置误差和速度误差也较小。 展开更多
关键词 惯性导航系统 全球卫星定位系统 磁力计 卡尔曼滤波 伪距 载波相位
在线阅读 下载PDF
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography 被引量:9
7
作者 Jian-Jun Li Peng-Cheng Du +3 位作者 Ji-Qing Fu Xu-Tong Wang Qing Zhou Ru-Quan Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第4期145-149,共5页
A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated... A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated four SERF magnetometer channels, which provides sufficient spatial resolution for magnetoencephalography(MEG). The four channels share the same laser beam for the best cancellation of common mode noise due to laser fluctuations. With gradient measurement, the sensitivities of the four sensors are better than 6 fT/Hz^(1/2), which is also good enough for MEG measurement. The vapor cell is heated to 160℃ by a novel nonmagnetic current-heating structure. Our sensor with high spatial resolution and compact size is particularly suitable for MEG systems. 展开更多
关键词 multi-channel SPIN-EXCHANGE relaxation-free optically PUMPED atomic magnetometer magne-toencephalography
原文传递
Pico-satellite Autonomous Navigation with Magnetometer and Sun Sensor Data 被引量:8
8
作者 HAN Ke WANG Hao TU Binjie JIN Zhonghe 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2011年第1期46-54,共9页
This article presents a near-Earth satellite orbit estimation method for pico-satellite applications with light-weight and low-power requirements. The method provides orbit information autonomously from magnetometer a... This article presents a near-Earth satellite orbit estimation method for pico-satellite applications with light-weight and low-power requirements. The method provides orbit information autonomously from magnetometer and sun sensor, with an extended Kalman filter (EKF). Real-time position/velocity parameters are estimated with attitude independently from two quantities: the measured magnitude of the Earth’s magnetic field, and the measured dot product of the magnetic field vector and the sun vector. To guarantee the filter’s effectiveness, it is recommended that the sun sensor should at least have the same level of accuracy as magnetometer. Furthermore, to reduce filter’s computation expense, simplification methods in EKF’s Jacobian calculations are introduced and testified, and a polynomial model for fast magnetic field calculation is developed. With these methods, 50% of the computation expense in dynamic model propagation and 80% of the computation burden in measurement model calculation can be reduced. Tested with simulation data and compared with original magnetometer-only methods, filter achieves faster convergence and higher accuracy by 75% and 30% respectively, and the suggested simplification methods are proved to be harmless to filter’s estimation performance. 展开更多
关键词 pico-satellite autonomous navigation orbit estimation magnetometer Kalman filter
原文传递
An improved quaternion Gauss–Newton algorithm for attitude determination using magnetometer and accelerometer 被引量:7
9
作者 Liu Fei Li Jie +1 位作者 Wang Haifu Liu Chang 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2014年第4期986-993,共8页
For the vector attitude determination, the traditional optimal algorithms which are based on quaternion estimator(QUEST) measurement noise model are complicated for just two observations. In our application, the mag... For the vector attitude determination, the traditional optimal algorithms which are based on quaternion estimator(QUEST) measurement noise model are complicated for just two observations. In our application, the magnetometer and accelerometer are not two comparable kinds of sensors and both are not small field-of-view sensors as well. So in this paper a new unit measurement model is derived. According to the Wahba problem, the optimal weights for each measurement are obtained by the error variance researches. Then an improved quaternion Gauss–Newton method is presented and adopted to acquire attitude. Eventually, simulation results and experimental validation employed to test the proposed method demonstrate the usefulness of the improved algorithm. 展开更多
关键词 ACCELEROMETER Attitude determination Gauss-Newton algorithm magnetometer MEASUREMENTS
原文传递
Observing the steady-state visual evoked potentials with a compact quad-channel spin exchange relaxation-free magnetometer 被引量:5
10
作者 Peng-Cheng Du Jian-Jun Li +4 位作者 Si-Jia Yang Xu-Tong Wang Yan Zhuo Fan Wang Ru-Quan Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第4期141-144,共4页
We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of ... We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI). 展开更多
关键词 optically pumped magnetometerS steady-state visually EVOKED potentials MAGNETOENCEPHALOGRAPHY
原文传递
Magnetometer-only linear attitude estimation for bias momentum pico-satellite 被引量:5
11
作者 Ke HAN Hao WANG Zhong-he JIN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2010年第6期455-464,共10页
Satellite attitude information is essential for pico-satellite applications requiring light-weight,low-power,and fast-computation characteristics.The objective of this study is to provide a magnetometer-only attitude ... Satellite attitude information is essential for pico-satellite applications requiring light-weight,low-power,and fast-computation characteristics.The objective of this study is to provide a magnetometer-only attitude estimation method for a low-altitude Earth orbit,bias momentum pico-satellite.Based on two assumptions,the spacecraft spherical symmetry and damping of body rates,a linear kinematics model of a bias momentum satellite's pitch axis is derived,and the linear estimation algorithm is developed.The algorithm combines the linear Kalman filter(KF) with the classic three-axis attitude determination method(TRIAD).KF is used to estimate satellite's pitch axis orientation,while TRIAD is used to obtain information concerning the satellite's three-axis attitude.Simulation tests confirmed that the algorithm is suited to the time-varying model errors resulting from both assumptions.The estimate result keeps tracking satellite attitude motion during all damping,stable,and free rotating control stages.Compared with nonlinear algorithms,such as extended Kalman filer(EKF) and square root unscented Kalman filer(SRUKF),the algorithm presented here has an almost equal performance in terms of convergence time and estimation accuracy,while the consumption of computing resources is much lower. 展开更多
关键词 Pico-satellite Attitude estimation Bias momentum magnetometer Kalman filter(KF)
原文传递
China Seismo-Electromagnetic Satellite search coil magnetometerdata and initial results 被引量:9
12
作者 Qiao Wang JianPing Huang +4 位作者 XueMin Zhang XuHui Shen ShiGeng Yuan Li Zeng JinBin Cao 《Earth and Planetary Physics》 2018年第6期462-468,共7页
Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the wavefo... Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances. 展开更多
关键词 search coil magnetometer CSES data description EARTHQUAKE
在线阅读 下载PDF
Magnetometer Compensation Scheme and Experimental Results on ZDPS-1A Pico-satellite 被引量:3
13
作者 HAN Ke WANG Hao +1 位作者 XIANG Tian JIN Zhonghe 《Chinese Journal of Aeronautics》 SCIE EI CSCD 2012年第3期430-436,共7页
In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compe... In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compensation methods is introduced in this article. The scheme is based on an improved meast, rement model of pico-satellite TAM, and it mainly consists of three steps. First, in satellite design stage, several techniques are recommended to simplify the afterwards compensations. Then after satellite assembly, TAM ground tests and pre-launch calibration with least-square batch filter are introduced to improve magnetometer performance. At the end, a post-launch calibration with unscented Kalman filter (UKF) is implemented with in-orbit data. The compensation scheme is used in the development of Chinese pico-satellite ZDPS-1A made by Zhejiang University. Results show that with the introduced compensation scheme, the maximum error of ZDPS-1A TAM can be reduced from 80 mG to 6 naG (1 G=10^-4T). 展开更多
关键词 pico-satellite magnetometerS calibration: least-square filter Kalman filter
原文传递
Spin dynamics of the potassium magnetometer in spin-exchange relaxation free regime 被引量:2
14
作者 伏吉庆 杜鹏程 +1 位作者 周庆 王如泉 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期436-439,共4页
The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium... The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium SERF magne- tometer. A pump-probe approach is used to identify the unique spin dynamics of the atomic ensemble in the SERF regime. A single channel sensitivity of 8 f.THz-1/2 is achieved with our SERF magnetometer. 展开更多
关键词 Larmor process spin-exchange relaxation free magnetometer atomic magnetometer
原文传递
Transverse relaxation determination based on light polarization modulation for spin-exchange relaxation free atomic magnetometer 被引量:4
15
作者 Xue-Jing Liu Ming Ding +3 位作者 Yang Li Yan-Hui Hu Wei Jin Jian-Cheng Fang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期276-280,共5页
A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intens... A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intensity excitation meth- ods used in SERF magnetometer, the light polarization modulation method has a high stability in low-frequency range, which indicates a more accurate transverse relaxation measurement. 展开更多
关键词 spin-exchange relaxation free (SERF) magnetometer LINEWIDTH optical polarization modulation
原文传递
Mars Orbiter magnetometer of China’s First Mars Mission Tianwen-1 被引量:13
16
作者 Kai Liu XinJun Hao +7 位作者 YiRen Li TieLong Zhang ZongHao Pan ManMing Chen XiaoWen Hu Xin Li ChengLong Shen YuMing Wang 《Earth and Planetary Physics》 CSCD 2020年第4期384-389,共6页
As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction wi... As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction with the solar wind.The instrument consists of two identical triaxial fluxgate magnetometer sensors,mounted on a 3.19 meter-long boom with a seperation of about 90 cm.The dual-magnetometers configuration will help eliminate the magnetic field interference generated by the spacecraft platform and payloads.The sensors are controlled by an electric box mounted inside the orbiter.Each magnetometer measures the ambient vector magnetic field over a wide dynamic range(to 10,000 nT per axis)with a resolution of 1.19 pT.Both magnetometers sample the ambient magnetic field at an intrinsic frequency of 128 Hz,but will operate in a model with alternating frequency between 1 and 32 Hz to meet telemetry allocations. 展开更多
关键词 MARS magnetic field magnetometer Tianwen-1 spaceflight instrumentation
在线阅读 下载PDF
Chinese Antarctic Magnetometer Chain at the Cusp Latitude 被引量:2
17
作者 LIU Yonghua HU Hongqiao +14 位作者 YANG Huigen ZHANG Beichen SUN Bo WEI Fuhai LIU Yang LIU Jianjun WANG Rui CHEN Zhuotian HU Zejun HAN Desheng SHI Guitao HU Zhengyi WANG Tao AN Chunlei Mike Rose 《Advances in Polar Science》 2016年第2期102-106,共5页
A Chinese Antarctic Magnetometer (CAM) chain from Zhongshan Station (ZHS) to Dome-A (DMA) has been established since February 2009. A regular magnetometer is operated at ZHS, and four low power magnetometers are... A Chinese Antarctic Magnetometer (CAM) chain from Zhongshan Station (ZHS) to Dome-A (DMA) has been established since February 2009. A regular magnetometer is operated at ZHS, and four low power magnetometers are operated along the interior route from ZHS to DMA in the cusp latitude, extending over a distance of 1260 km. These stations fill an important void in the Antarctic magnetometer network. Furthermore, the CAM chain is magnetically conjugated with the Arctic region reaching from the Svalbard archipelago to Daneborg, on the east coast of Greenland. Conjugate measurements using the Arctic and Antarctic magnetometers provide excellent opportunities to investigate phenomena related to the coupling of the solar wind to the magnetosphere and ionosphere, such as magnetic impulse events, flux transfer events, traveling convection vortices and ultra-low frequency waves. 展开更多
关键词 magnetometerS magnetic perturbation cusp latitude CONJUGATE
在线阅读 下载PDF
High contrast atomic magnetometer based on coherent population trapping 被引量:2
18
作者 杨爱林 杨国卿 +1 位作者 徐云飞 林强 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期477-480,共4页
We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. The experimental resul... We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. The experimental results show that a lin||lin tran- sition scheme is a promising alternative to the conventional circular-circular transition scheme for an atomic magnetometer. Compared with the circular light transition scheme, linear light accounts for high-contrast transmission resonances, which makes this excitation scheme promising for high-sensitivity magnetometers. We also use linear light and circular light to detect changes of a standard magnetic field, separately. 展开更多
关键词 high contrast atomic magnetometer coherent population trapping
原文传递
Low-T_c direct current superconducting quantum interference device magnetometer-based 36-channel magnetocardiography system in a magnetically shielded room 被引量:1
19
作者 邱阳 李华 +7 位作者 张树林 王永良 孔祥燕 张朝祥 张永升 徐小峰 杨康 谢晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期590-594,共5页
We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR)... We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR). Weakly damped SQUID magnetometers with large Steward–Mc Cumber parameter βc(βc≈ 5), which could directly connect to the operational amplifier without any additional feedback circuit, were used to simplify the readout electronics. With a flux-to-voltage transfer coefficient V / Φ larger than 420 μV/Φ0, the SQUID magnetometers had a white noise level of about 5.5 f T·Hz-1/2when operated in MSR. 36 sensing magnetometers and 15 reference magnetometers were employed to realize software gradiometer configurations. The coverage area of the 36 sensing magnetometers is 210×210 mm2. MCG measurements with a high signal-to-noise ratio of 40 d B were done successfully using the developed system. 展开更多
关键词 superconducting quantum interference devices magnetometer MAGNETOCARDIOGRAPHY noise can-cellation
原文传递
A Quaternion Scaled Unscented Kalman Estimator for Inertial Navigation States Determination Using INS/GPS/Magnetometer Fusion 被引量:4
20
作者 Wassim Khoder Bassem Jida 《Journal of Sensor Technology》 2014年第2期101-117,共17页
This Inertial Navigation System (INS), Global Positioning System (GPS) and fluxgate magnetometer technologies have been widely used in a variety of positioning and navigation applications. In this paper, a low cost so... This Inertial Navigation System (INS), Global Positioning System (GPS) and fluxgate magnetometer technologies have been widely used in a variety of positioning and navigation applications. In this paper, a low cost solid state INS/GPS/Magnetometer integrated navigation system has been developed that incorporates measurements from an Inertial Navigation System (INS), Global Positioning System (GPS) and fluxgate magnetometer (Mag.) to provide a reliable complete navigation solution at a high output rate. The body attitude estimates, especially the heading angle, are fundamental challenges in a navigation system. Therefore targeting accurate attitude estimation is considered a significant contribution to the overall navigation error. A better estimation of the body attitude estimates leads to more accurate position and velocity estimation. For that end, the aim of this research is to exploit the magnetometer and accelerometer data in the attitude estimation technique. In this paper, a Scaled Unscented Kalman Filter (SUKF) based on the quaternion concept is designed for the INS/GPS/Mag integrated navigation system under large attitude error conditions. Simulation and experimental results indicate a satisfactory performance of the newly developed model. 展开更多
关键词 INERTIAL Navigation System INERTIAL Sensor Model GPS magnetometer QUATERNION ATTITUDE PARAMETERIZATION Rotation Vector Scaled Augmented Unscented KALMAN Filter
暂未订购
上一页 1 2 64 下一页 到第
使用帮助 返回顶部