期刊文献+
共找到41,960篇文章
< 1 2 250 >
每页显示 20 50 100
In-situ observation of nonmetallic inclusions in steel using confocal scanning laser microscopy:A review 被引量:1
1
作者 Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2025年第5期975-991,共17页
The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are revi... The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are reviewed and summarized,particularly the col-lision of various inclusions,dissolution of inclusions in liquid slag,and reactions between inclusions and steel.Solid inclusions exhibited a high collision tendency,whereas pure liquid inclusions exhibited minimal collisions because of the small attraction force induced by their<90°contact angle with molten steel.The collision of complex inclusions in molten steel was not included in the scope of this study and should be evaluated in future studies.Higher CaO/Al_(2)O_(3)and CaO/SiO_(2)ratios in liquid slag promoted the dissolution of Al_(2)O_(3)-based in-clusions.The formation of solid phases in the slag should be prevented to improve dissolution of inclusions.To accurately simulate the dissolution of inclusions in liquid slag,in-situ observation of the dissolution of inclusions at the steel-slag interface is necessary.Using a combination of CSLM and scanning electron microscopy-energy dispersive spectroscopy,the composition and morphological evolution of the inclusions during their modification by the dissolved elements in steel were observed and analyzed.Although the in-situ observa-tion of MnS and TiN precipitations has been widely studied,the in-situ observation of the evolution of oxide inclusions in steel during so-lidification and heating processes has rarely been reported.The effects of temperature,heating and cooling rates,and inclusion character-istics on the formation of acicular ferrites(AFs)have been widely studied.At a cooling rate of 3-5 K/s,the order of AF growth rate in-duced by different inclusions,as reported in literature,is Ti-O<Ti-Ca-Zr-Al-O<Mg-O<Ti-Zr-Al-O<Mn-Ti-Al-O<Ti-Al-O<Zr-Ti-Al-O.Further comprehensive experiments are required to investigate the quantitative relationship between the formation of AFs and inclusions. 展开更多
关键词 INCLUSION STEEL in-situ observation confocal scanning laser microscopy
在线阅读 下载PDF
In-situ observation and analysis of high temperature behavior of carbides in GCr15 bearing steel by confocal laser scanning microscopy 被引量:1
2
作者 Jun Ren Yue Teng +4 位作者 Xiang Liu Xi Xu Hui-gai Li Ke Han Qi-jie Zhai 《Journal of Iron and Steel Research International》 2025年第2期409-417,共9页
The high-temperature dissolution behavior of primary carbides in samples taken from GCr15 continuous-casting bloom was observed in-situ by confocal laser scanning microscopy.Equations were fitted to the dissolution ki... The high-temperature dissolution behavior of primary carbides in samples taken from GCr15 continuous-casting bloom was observed in-situ by confocal laser scanning microscopy.Equations were fitted to the dissolution kinetics of primary carbides during either heating or soaking.Dissolution of carbides proceeded in three stages(fast→slow→faster)as either temperature or holding time was increased.During the heating process and during the first and third stages of the soaking process,the original size of the carbides determined the steepness of the slope,but during the middle(“slow”)stage of the soaking process,the slope remained zero.The initial size of the carbides varied greatly,but their final dissolution temperature fell within the narrow range of 1210-1235℃,and the holding time remained within 50 min.Fractal analysis was used to study the morphological characteristics of small and medium-sized carbides during the dissolution process.According to changes in the fractal dimension before and after soaking,the carbides tended to evolve towards a more regular morphology. 展开更多
关键词 Bearing steel High-temperature confocal laser scanning microscope In-situ observation Primary carbide Fractal analysis
原文传递
A centroid measurement method based on 3D scanning 被引量:1
3
作者 HE Xin LI Zhen 《Journal of Measurement Science and Instrumentation》 2025年第2期186-194,共9页
The centroid coordinate serves as a critical control parameter in motion systems,including aircraft,missiles,rockets,and drones,directly influencing their motion dynamics and control performance.Traditional methods fo... The centroid coordinate serves as a critical control parameter in motion systems,including aircraft,missiles,rockets,and drones,directly influencing their motion dynamics and control performance.Traditional methods for centroid measurement often necessitate custom equipment and specialized positioning devices,leading to high costs and limited accuracy.Here,we present a centroid measurement method that integrates 3D scanning technology,enabling accurate measurement of centroid across various types of objects without the need for specialized positioning fixtures.A theoretical framework for centroid measurement was established,which combined the principle of the multi-point weighing method with 3D scanning technology.The measurement accuracy was evaluated using a designed standard component.Experimental results demonstrate that the discrepancies between the theoretical and the measured centroid of a standard component with various materials and complex shapes in the X,Y,and Z directions are 0.003 mm,0.009 mm,and 0.105 mm,respectively,yielding a spatial deviation of 0.106 mm.Qualitative verification was conducted through experimental validation of three distinct types.They confirmed the reliability of the proposed method,which allowed for accurate centroid measurements of various products without requiring positioning fixtures.This advancement significantly broadened the applicability and scope of centroid measurement devices,offering new theoretical insights and methodologies for the measurement of complex parts and systems. 展开更多
关键词 centroid measurement mass characteristic parameter 3D scanning 3D point cloud data no specialized positioning fixtures multi-point weighing method
在线阅读 下载PDF
Chromogenic Reactions of Starch and Dextrin and Comparative Study of Thin-Layer Chromatography of Oligosaccharides in 35 Batches of Jiulongteng Honey
4
作者 Beiqiao YIN Qi HUANG +4 位作者 Yanyan CHEN Shenggao YIN Zhiqiang ZHU Hanbai LIANG Hao HUANG 《Medicinal Plant》 2025年第4期24-28,共5页
[Objectives]To explore the methods for identifying pure honey.[Methods]Using 35 batches of Jiulongteng honey sourced from various production areas in Guangxi as the research subjects,this study investigated the chromo... [Objectives]To explore the methods for identifying pure honey.[Methods]Using 35 batches of Jiulongteng honey sourced from various production areas in Guangxi as the research subjects,this study investigated the chromogenic reactions of starch and dextrin,as well as the comparative study of thin-layer chromatography of oligosaccharides present in Jiulongteng honey.[Results]None of the 35 batches of Jiulongteng honey samples exhibited blue(indicating starch),green,or reddish-brown(indicating dextrin)coloration,suggesting that no adulterants such as artificially added starch,dextrin,or sugar were present in these samples.Furthermore,none of the 35 batches displayed additional spots below the corresponding positions of the control,indicating that the sugar composition was consistent with the oligosaccharide profile of natural honey.No components inconsistent with the oligosaccharide profile of natural honey were detected.Therefore,it can be concluded that the Jiulongteng honey samples in this experiment were pure and free from adulteration with starch,dextrin,or other sugar substances.[Conclusions]The method employed in this experiment is straightforward and quick to implement,effectively preventing adulterated honey from entering the market.It enhances the efficiency of quality control for Jiulongteng honey and promotes the healthy development of the Jiulongteng honey industry. 展开更多
关键词 Jiulongteng honey Chromogenic reaction thin-layer chromatography STARCH DEXTRIN
在线阅读 下载PDF
An investigation of single-phased metallic solidification process using high-temperature confocal laser scanning microscope combined with differential scanning colorimetry
5
作者 Xing-zhi Zhou De-yong Wang +6 位作者 Tian-peng Qu Dong Hou Shao-yan Hu Jun Tian Xiang-long Li Lei Fan Zhi-xiao Zhang 《Journal of Iron and Steel Research International》 2025年第2期437-451,共15页
To investigate the nucleation behavior during the single-phased metallic solidification process,the commercial ultrapure ferritic stainless steels with no(Initial steel)and various melt treatments(R1,MR1,Y2,MY1,and M1... To investigate the nucleation behavior during the single-phased metallic solidification process,the commercial ultrapure ferritic stainless steels with no(Initial steel)and various melt treatments(R1,MR1,Y2,MY1,and M1 steels)were used to carry out the differential scanning colorimetry(DSC)and high-temperature confocal laser scanning microscope(HT-CLSM)experiments.Based on the results of DSC experiments,the equilibrium solidification process as well as the relationship among the critical undercooling degree(△T_(c)^(DSC)),latent heat of fusion/crystallization(△H_(f)/△H_(c)),equiaxed grain ratio(ER),and average grain size(△_(ave)^(ingot))was revealed.ER is increased with the decreasing△T_(c)^(DSC)and increasing△H_(f)/△H_(c);however,△_(ave)^(ingot)is decreased with them.Referring to the results of HT-CLSM experiments,the average sizes of micro-/macrostructures(d_(ave)/D_(ave)/)are decreased with the increasing cooling rate,as well as the difference between and apparent critical undercooling degree(△T_(c)^(CLSM))was revealed.The heterogeneous nucleation of the crystal nuclei occurs only if△T_(c)^(CLSM)>△T_(c)^(DSC).Combining with the interfacial wetting-lattice mismatch heterogeneous nucleation model,the dynamic mechanism of the metallic solidification was revealed.The as-cast grains of the melt-treated samples were obviously refined,owing to the much higher actual heterogeneous nucleation rates(I_(heter.,i))obtained through melt treatments,and the heterogeneous nucleation rates(I_(heter.,ij))for all samples are increased with the cooling rates,firmly confirming that the as-cast grains of each sample could be refined by the increasing cooling rates. 展开更多
关键词 NUCLEATION Metallic solidification process Differential scanning colorimetry High-temperature confocal laser scanning microscope Interfacial wetting-lattice mismatch heterogeneous nucleation model
原文传递
Hemoglobin oxygen saturation in myopic eyes:a scanning laser ophthalmoscope study
6
作者 Zi-Xuan Xiao Kun-Liang Qiu +3 位作者 Hui Zhou De-Zhi Zheng Tsz Kin Ng Geng Wang 《International Journal of Ophthalmology(English edition)》 2025年第11期2130-2136,共7页
AIM:To evaluate retinal hemoglobin oxygen saturation in myopic eyes by scanning laser ophthalmoscope(SLO)and to assess its correlations with different severity of myopia.METHODS:Sixty-one eyes from 61 patients were in... AIM:To evaluate retinal hemoglobin oxygen saturation in myopic eyes by scanning laser ophthalmoscope(SLO)and to assess its correlations with different severity of myopia.METHODS:Sixty-one eyes from 61 patients were included and subdivided into three groups according to their refractive errors:high myopia group[20 eyes,spherical equivalent(SE)≤-6 D];low and moderate myopia(22 eyes,-6.0<SE≤-0.5 D);normal(19 eyes,-0.5<SE<+0.5 D).All subjects underwent SLO imaging with dual lasers(532 nm and 633 nm).The oxygen saturations of hemoglobin in arteries(SO_(2)A)and veins(SO_(2)V),and their differences(SO_(2)AV)were estimated from the optical densities of the vessels on the images at the two wavelengths.Pearson’s or Spearman’s rank correlation coefficient were calculated to assess the correlation between retinal hemoglobin oxygen saturation and refractive error/axial length(AL).RESULTS:For the retinal oxygen saturation,the SO_(2)V in high myopia group(73.21%±21.42%)was significantly higher than that in normal group(55.81%±21.69%)and low and moderate myopia group(56.88%±13.83%,P<0.05).The SE was significantly correlated with SO_(2)A(r=-0.30)and SO_(2)V(r=-0.36;P<0.05),and AL was also significantly correlated with SO_(2)A(r=0.27)and SO_(2)V(r=0.30;P<0.05).No significant correlations were found between SO_(2)AV and SE and AL(P>0.05).CONCLUSION:SO_(2)A and SO_(2)V increased in more myopic eye based on SLO measurements.Further studies are warranted to investigate the changes of retinal hemoglobin oxygen saturation in myopia with different methods. 展开更多
关键词 MYOPIA RETINA hemoglobin oxygen saturation scanning laser ophthalmoscope
原文传递
Molecular conformational effects on co-assembly systems of low-symmetric carboxylic acids investigated by scanning tunneling microscopy
7
作者 Yutong Xiong Ting Meng +3 位作者 Wendi Luo Bin Tu Shuai Wang Qingdao Zeng 《Chinese Journal of Structural Chemistry》 2025年第2期57-61,共5页
The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-d... The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-dicarboxylic acid(BCBDA))containing naphthalene rings on graphite surfaces have been investigated using scanning tunneling microscopy(STM).The transformation of nanostructures induced by the second components(EDA and PEBP-C4)have been also examined.Both CTTA and BCBDA molecules self-assemble at the 1-heptanoic acid(HA)/HOPG interface,forming porous network structures.The dimer represents the most elementary building unit due to the formation of double hydrogen bonds.Moreover,the flipping of naphthalene ring results in the isomerization of BCBDA molecule.The introduction of carboxylic acid derivative EDA disrupts the dimer,which subsequently undergoes a structural conformation to form a novel porous structure.Furthermore,upon the addition of pyridine derivative PEBP-C4,N–H⋯O hydrogen bonds are the dominant forces driving the three coassembled structures.We have also conducted density functional theory(DFT)calculations to determine the molecular conformation and analyze the mechanisms underlying the formation of nanostructures. 展开更多
关键词 Co-assembly CONFORMATION Hydrogen bonds scanning tunneling microscopy DFT calculations
原文传递
Manipulation of vortex array via a magnetism-tunable spin-polarized scanning tunnelling microscopy
8
作者 Bing Xia Hong-Yuan Chen +13 位作者 Jian Zheng Bo Yang Jie Cai Yi Zhang Yi Yang Hao Yang Dan-Dan Guan Xiao-Xue Liu Liang Liu Yao-Yi Li Shi-Yong Wang Can-Hua Liu Hao Zheng Jin-Feng Jia 《Chinese Physics B》 2025年第3期190-194,共5页
Manipulating and braiding Majorana zero modes(MZM)are a critical step toward realizing topological quantum computing.The primary challenge is controlling the vortex,which hosts the MZM,within a superconducting film in... Manipulating and braiding Majorana zero modes(MZM)are a critical step toward realizing topological quantum computing.The primary challenge is controlling the vortex,which hosts the MZM,within a superconducting film in a spatially precise manner.To address this,we developed a magnetic force-based vortex control technology using the STM system with a self-designed four-electrode piezo-scanner tube and investigated vortex manipulation on the NbSe_(2) superconducting film.We employed ferromagnetic tips to control the movement of vortex array induced by the tip's remanent magnetism.A magnetic core solenoid device was integrated into the STM system and a strong magnetic tip demagnetization technique was developed,providing a viable technical solution for further enabling single vortex manipulation. 展开更多
关键词 vortex manipulation scanning tunneling microscope magnetic tip demagnetization technique
原文传递
Optical manipulation of neuronal mitochondria using scanning optical tweezers
9
作者 Zhiyong Gong Tianli Wu +4 位作者 Xixi Chen Ping Wang Jinghui Guo Yuchao Li Baojun Li 《Journal of Innovative Optical Health Sciences》 2025年第4期205-214,共10页
Mitochondria play a crucial role in the physiological functions and energy metabolism of neurons,which can help in the understanding of complex biochemical reactions associated with various neurodegenerative diseases.... Mitochondria play a crucial role in the physiological functions and energy metabolism of neurons,which can help in the understanding of complex biochemical reactions associated with various neurodegenerative diseases.Neurons,being highly differentiated terminal cells,require a greater number of mitochondria than ordinary cells to generate significant amounts of ATP,which is necessary for the growth of differentiated neuronal structures like axons and dendrites and the transmission of electrical signals along neuronal axons.Advancements in imaging technology,electrophysiology,and fluorescence targeting labeling have facilitated the study of mitochondrial movements in neurons and axons.However,disordered mitochondrial movements can hinder their analysis and characterization.Thus,it becomes necessary to artificially control their transport.Here,we demonstrate the utilization of scanning optical tweezers(SOTs)on the stable trapping and precise transport of soma or axon of neurons and enable.The presented method provides an optical approach to the control of mitochondria or other organelles in complex and variable biological environment. 展开更多
关键词 scanning optical tweezers neuronal mitochondrial transport optical trapping
原文传递
Dual-Polarized 2D Beam-Scanning Antenna Based on Reconfigurable Reflective Elements
10
作者 LIU Zhipeng LI Kexin +2 位作者 CAI Yuanming LIU Feng GUO Jiayin 《ZTE Communications》 2025年第1期85-89,共5页
In this paper,a dual-polarized antenna operating at 3.5 GHz is presented with 2D beam-scanning performance.The steerable beam is realized based on a 2×2 active reflective metasurface.The active metasurface is com... In this paper,a dual-polarized antenna operating at 3.5 GHz is presented with 2D beam-scanning performance.The steerable beam is realized based on a 2×2 active reflective metasurface.The active metasurface is composed of folded annular rings and cross dipoles embedded with voltage-controlled varactor diodes.By tuning the capacitance values of the varactors,the reflective phase of the metasurface is reconfigured to tilt the main beam.To verify the scanning performance,a prototype is fabricated and measured.At 3.5 GHz,the measured scanning ranges are from-25°to 29°and-27°to 29°in the XOZ and YOZ planes,respectively. 展开更多
关键词 dual-polarized antenna reflective metasurface 2D beam scanning varactor diode
在线阅读 下载PDF
Optimizing Contrast-Enhanced Magnetic Resonance Neurography of the Brachial Plexus With Delayed Scanning
11
作者 Jun Xu Xiaoli Hu +7 位作者 Xiaoyun Su Shen Gui Ziqiao Lei Xiaoming Liu Xiangzhi Zhou Lixia Wang Wenjun Wu Xiangchuang Kong 《iRADIOLOGY》 2025年第2期168-175,共8页
Background:Contrast-enhanced magnetic resonance neurography(ceMRN)can enhance brachial plexus visualization and quality of imaging.However,the interval between contrast injection and scanning that provides the highest... Background:Contrast-enhanced magnetic resonance neurography(ceMRN)can enhance brachial plexus visualization and quality of imaging.However,the interval between contrast injection and scanning that provides the highest-quality images is not known.Methods:Fifteen patients underwent brachial plexus imaging using the 3D T2-NerveView sequence with a scanning duration of 5 min.A consecutive six-phase scan was initiated immediately at the start of contrast agent injection.Subsequently,all patients'images were classified into six groups according to the phases:group A(phase 1,delay 0 min),group B(phase 2,delay 5 min),group C(phase 3,delay 10 min),group D(phase 4,delay 15 min),group E(phase 5,delay 20 min),and group F(phase 6,delay 25 min).The image quality in each group was assessed based on nerve signal(signalnerve),muscle signal(signalmuscle),lymph node signal(signallymph node),background noise(BN),signal-to-noise ratio(SNR),contrast-to-noise ratio(CNR),and subjective score.Results:Signalnerve,signalmuscle,BN,and SNR did not significantly differ among the six groups(p>0.05).However,significant differences(p<0.05)were observed in signallymph node(F=16.067),CNR(F=9.495),and subjective score(χ^(2)=23.586).As the scanning delay increased,signallymph node intensity gradually increased whereas the CNR gradually decreased.The subjective score was significantly higher in groups B(4.830.24),C(4.900.21),D(4.870.30),E(4.830.31),and F(4.830.31)than in group A(4.470.30).Conclusion:We recommend performing brachial plexus ceMRN 5 min after contrast injection.With this delay,the brachial plexus can be visualized optimally with minimal interference from background signals. 展开更多
关键词 brachial plexus compressed sensing delayed scanning image quality magnetic resonance neurography
暂未订购
Mechanism of keyhole evolution and welding quality of electron beam welded magnesium alloy with scanning path variation via modeling and numerical study
12
作者 Qianxing Yin Ziyou Yang +1 位作者 Hui Li Hejun Du 《Journal of Magnesium and Alloys》 2025年第7期3166-3185,共20页
Welding quality of electron beam welded joint is usually susceptible to the stability of keyhole during welding process.The more stable the keyhole,the better the welding quality.To reveal the evolution mechanism of k... Welding quality of electron beam welded joint is usually susceptible to the stability of keyhole during welding process.The more stable the keyhole,the better the welding quality.To reveal the evolution mechanism of keyhole and welding quality of the electron beam welded joint of magnesium-gadolinium alloy under different scanning path,numerical simulation was conducted for the changes in morphology of keyhole and liquid flow in molten pool.The magnesium-gadolinium alloy was welded by electron beam in vacuum with two different scanning paths,sinusoid path and cochleoid path,indicating the identical heat input,welding speed,and focusing state.The stability of keyhole was mainly related to the frequency of keyhole collapse.When the sinusoid scanning path was adopted,the fluids both inside the molten pool and at keyhole wall were disorder,corresponding to the numerous independent vortices and dramatically chaotic flows at their junctions.The maximum velocity of fluids ranged from 0.79 m/s to 1.02 m/s.The average and maximum depth of keyhole were 3.48 mm and 4.51 mm,respectively,meaning that the keyhole collapsed frequently.As the scanning path was changed into cochleoid mode,the electron beam scanned in a homogeneous manner without abrupt change in direction and speed like sinusoid path at its peaks and troughs.The maximum velocity of fluids was more uniform without drastic variation,ranging from 0.90 m/s to 1.01 m/s.The average and maximum depth of keyhole were decreased to 3.30 mm and 4.05 mm,respectively,indicating the more stable keyhole and alleviated collapse.Both the actual in-situ capture of molten pool signature and porosity inside the weld corresponded to the analysis of the change in keyhole stability. 展开更多
关键词 Magnesium-gadolinium alloy Keyhole stability Electron beam welding scanning path Fluid flow
在线阅读 下载PDF
Fine-Grained Point Cloud Intensity Correction Modeling Method Based on Mobile Laser Scanning
13
作者 Xu Liu Qiujie Li +3 位作者 Youlin Xu Musaed Alhussein Khursheed Aurangzeb Fa Zhu 《Computers, Materials & Continua》 2025年第4期575-593,共19页
The correction of Light Detection and Ranging(LiDAR)intensity data is of great significance for enhancing its application value.However,traditional intensity correction methods based on Terrestrial Laser Scanning(TLS)... The correction of Light Detection and Ranging(LiDAR)intensity data is of great significance for enhancing its application value.However,traditional intensity correction methods based on Terrestrial Laser Scanning(TLS)technology rely on manual site setup to collect intensity training data at different distances and incidence angles,which is noisy and limited in sample quantity,restricting the improvement of model accuracy.To overcome this limitation,this study proposes a fine-grained intensity correction modeling method based on Mobile Laser Scanning(MLS)technology.The method utilizes the continuous scanning characteristics of MLS technology to obtain dense point cloud intensity data at various distances and incidence angles.Then,a fine-grained screening strategy is employed to accurately select distance-intensity and incidence angle-intensity modeling samples.Finally,based on these samples,a high-precision intensity correction model is established through polynomial fitting functions.To verify the effectiveness of the proposed method,comparative experiments were designed,and the MLS modeling method was validated against the traditional TLS modeling method on the same test set.The results show that on Test Set 1,where the distance values vary widely(i.e.,0.1–3 m),the intensity consistency after correction using the MLS modeling method reached 7.692 times the original intensity,while the traditional TLS modeling method only increased to 4.630 times the original intensity.On Test Set 2,where the incidence angle values vary widely(i.e.,0○–80○),the MLS modeling method,although with a relatively smaller advantage,still improved the intensity consistency to 3.937 times the original intensity,slightly better than the TLS modeling method’s 3.413 times.These results demonstrate the significant advantage of the modeling method proposed in this study in enhancing the accuracy of intensity correction models. 展开更多
关键词 LIDAR intensity correction mobile laser scanning distance and incidence angle MODELING
在线阅读 下载PDF
The Scanning Secondary Moire Method with Atomic-Level Resolution and Large Micrometer-Scale Field of View
14
作者 Yao Zhao Yueyue Xu +4 位作者 Zhanwei Liu Jiangfan Zhou Han Liu Jianxin Nie Jinzhao Zhao 《Acta Mechanica Solida Sinica》 2025年第2期300-308,共9页
The measurement field of view of the conventional transmission electron microscopy(TEM)nano-moiréand scanning transmission electron microscopy(STEM)nano-moirémethods is limited to the hundred-nanometer scale... The measurement field of view of the conventional transmission electron microscopy(TEM)nano-moiréand scanning transmission electron microscopy(STEM)nano-moirémethods is limited to the hundred-nanometer scale,unable to meet the deformation field measurement requirements of micrometer-scale materials such as transistors and micro-devices.This paper proposed a novel measurement method based on scanning secondary moire,which can realize cross-scale deformation field measurement from nanometers to micrometers and solve the problem of insufficient measurement accuracy when using only the TEM moire method.This method utilized the electron wave in the TEM passing through the atomic lattice of two layers of different materials to generate TEM moire.On this basis,the TEM was tuned to the STEM mode,and by adjusting parameters such as the amount of defocusing,magnification,scanning angle,etc.,the electron beam was focused on the position near the interface of the two layers of materials,and at the same time,the scanning line was made approximately parallel to the direction of one of the TEM moire fringes.The scanning secondary moire patterns were generated when the scanning spacing was close to the TEM moire spacing.Through this method,the deformation field,mechanical properties,and internal defects of crystals can be detected by a large field of view with high sensitivity and high efficiency.Compared to traditional methods,the advantages of scanning secondary moire method lie in significantly improving the measurement field of TEM moire and STEM moire methods,realizing the cross-scale visualization measurement from nanometers to micrometers,and possessing atomic-level displacement measurement sensitivity.It can also simplify and efficiently identify dislocations,offering a new method for large-area visualization observation of dislocation density in broad application prospects. 展开更多
关键词 Nano-moire scanning secondary moire Deformation fields Cross-scale visualization measurement Dislocation density
原文传递
Application of high-temperature confocal scanning laser microscopy to investigate non-metallic inclusions in steel:a review
15
作者 N.Preisser Y.Wang +3 位作者 J.Cejka I.Gruber W.Mu S.K.Michelic 《Journal of Iron and Steel Research International》 2025年第2期334-352,共19页
High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations an... High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations and solidification,this method has gained traction in the field of non-metallic inclusion in steels in recent years.An overview of the experimental capabilities of HT-CSLM and the most important results of recent investigations regarding the topics of clean steel production are provided.It includes the formation of intragranular acicular ferrite(IAF)from the surface of non-metallic inclusions during the continuous cooling and heat treatment,which can be especially beneficial in the toughness of heat-affected zones of welded pieces.Furthermore,the investigation of agglomeration mechanisms of non-metallic inclusions(NMIs)in liquid steel is discussed to improve the insight into attraction forces between particles and clogging phenomena during continuous casting.Also,the dissolution of NMIs in various steelmaking slags can be observed by HT-CSLM to compare dissolution rates and mechanisms of NMI,where significant influences of temperature and chemical composition of the slag were shown.Last but not least,the experimental work regarding the interface between steel and slag is discussed,where novel techniques are currently being developed.A comprehensive summary of experimental techniques using HT-CSLM equipment to investigate different interactions of NMIs with steel and slag phases is compiled. 展开更多
关键词 Non-metallic inclusion STEEL High-temperature confocal scanning laser microscopy Interfacial phenomenon KINETICS
原文传递
Evaluating tree branch angle measurements of European beech using terrestrial laser scanning
16
作者 Xi Peng Kim Calders +1 位作者 Louise Terryn Hans Verbeeck 《Forest Ecosystems》 2025年第2期220-230,共11页
Branch angles are an important plant morphological trait affecting light interception within forest canopies.However,studies on branch angles have been limited due to the time-consuming nature of manual measurements u... Branch angles are an important plant morphological trait affecting light interception within forest canopies.However,studies on branch angles have been limited due to the time-consuming nature of manual measurements using a protractor.Terrestrial laser scanning(TLS),however,provides new opportunities to measure branch angles more efficiently.Despite this potential,studies validating branch angle measurements from TLS have been limited.Here,our aim is to evaluate both manual and automatic branch angle measurements of European beech from TLS data using traditional field-measurements with a protractor as a reference.We evaluated the accuracy of branch angle measurements based on four automated algorithms(aRchiQSM,TreeQSM,Laplacian,SemanticLaplacian)from TLS data.Additionally,we assessed different ways of manual branch angle measurements in the field.Our study was based on a dataset comprising 124 branch angles measured from six European beech in a European deciduous forest.Our results show that manual branch angle measurements from TLS data are in high agreement with the reference(root-mean-squared error,RMSE:[3.57°-4.18°],concordance correlation coefficient,CCC:[0.950.97])across different branch length positions.Automated algorithms also are in high agreement with the reference although RMSE is approximately twice as large compared to manual branch angle measurements from TLS(RMSE:[9.29°-10.55°],CCC:[0.830.86])with manual leaf points removal.When applying the automatic wood-leaf separation algorithm,the performance of the four methods declined significantly,with only approximately 20 branch angles successfully identified.Moreover,it is important to note that there is no influence of the measurement position(branch surface versus center)for branch angle measurements.However,for curved branches,the selection of branch measurement length significantly impacts the branch angle measurement.This study provides a comprehensive understanding of branch angle measurements in forests.We show that automated measurement methods based on TLS data of branch angles are a valuable tool to quantify branch angles at larger scales. 展开更多
关键词 Branch angle Measurement methods Quantitative structure models LAPLACIAN Semantic-laplacian Terrestrial laser scanning
在线阅读 下载PDF
Influence of Radio-Frequency Voltage on Electron Spin Resonance Spectroscopy in Scanning Tunneling Microscopy
17
作者 Jiaan Cao Lyuzhou Ye +1 位作者 Rui-Xue Xu Xiao Zheng 《Chinese Journal of Chemical Physics》 2025年第4期375-381,I0104,共8页
Over the last decade,the integra-tion of scanning tunneling mi-croscopy(STM)and electron spin resonance(ESR)spectroscopy has emerged as a powerful tool for measuring spin states of surface-adsorbed molecules.The radio... Over the last decade,the integra-tion of scanning tunneling mi-croscopy(STM)and electron spin resonance(ESR)spectroscopy has emerged as a powerful tool for measuring spin states of surface-adsorbed molecules.The radio-fre-quency voltage is a key physical quantity that influences STM-ESR spectra.However,the specific effect of radio-frequency voltage on the real-time electric current associated with STM-ESR sig-nal remains unclear.In this work,we employ the hierarchical equations of motion method to simulate the STM-ESR spectra of a single spin-1/2 surface-adsorbed molecule and track the temporal evolution of the electric current,thereby elucidating how the radio-frequency volt-age influences the features of STM-ESR spectra,the real-time electric current,and the char-acteristic frequencies conveyed by the electric current.These theoretical insights facilitate a deeper comprehension of experimental phenomena. 展开更多
关键词 Electron spin resonance scanning tunneling microscopy Radio-frequency volt-age Real-time electric current
在线阅读 下载PDF
Reduction of photoreceptor cell packing density in low or moderative myopia detected with adaptive optics scanning laser ophthalmoscopy
18
作者 Lin-Yi Lei Yue Zhao +2 位作者 Tang-Ren Cai Si-Guo Feng Jin Yao 《International Journal of Ophthalmology(English edition)》 2025年第4期683-690,共8页
AIM:To assess the variations in photoreceptor cell packing density(PCPD)across the retina among young healthy individuals with emmetropia,low and moderate myopia.METHODS:High-resolution adaptive optics scanning laser ... AIM:To assess the variations in photoreceptor cell packing density(PCPD)across the retina among young healthy individuals with emmetropia,low and moderate myopia.METHODS:High-resolution adaptive optics scanning laser ophthalmoscopy(AOSLO)systems were utilized for retinal imaging with a large sampling window of 700μm×700μm.The study cohort included 14 emmetropic[spherical equivalent(SE)ranged+0.5 to-0.5 D],15 low myopic(SE ranged-0.5 to-3 D)and 21 moderate myopic(SE ranged-3 to-6 D)healthy young adults.Photoreceptors at 3°temporal,6°superior and inferior 6°were captured.Statistical analysis was then performed to obtain PCPD and cell spacing.RESULTS:The average age of participants was 22.54±2.86(ranged 20–30y)with no difference among 3 groups.At 3°temporal,the emmetropic group exhibited the highest PCPD of 15186.16±2050.54 cells/mm^(2),while the low and moderate myopic groups had PCPD of 14009.15±1073.01 and 13466.92±1121.71 cells/mm2,respectively.At 3°temporal,the emmetropic group also had the smallest cell spacing at 6.66±0.26 mm,compared to 6.85±0.26 and 6.91±0.28 mm for the low and moderate myopic groups,respectively.Compared to the emmetropic group,at 3°temporal,the myopic groups showed significantly reduced PCPD(low myopia:P=0.032;moderate myopia:P=0.001).At 6°inferior,the moderate myopic group exhibited a significant decrease in PCPD(P=0.013),while at 6°superior,there were no significant statistical differences in PCPD for the low and moderate myopic groups(P>0.05).In comparison to the emmetropic group,only the moderate myopic group showed significantly increased cell spacing at all three positions(temporal 3°:P=0.011,superior 6°:P=0.046,inferior 6°:P=0.013).Correlation analysis revealed a positive correlation between PCPD and axial length changes(P<0.05).CONCLUSION:Reduced PCPD and increased cell spacing strongly correlated with refractive error in mild to moderate myopic eyes,especially at 6°inferior to the fovea and the decreased PCPD in the macular region of myopic patients may be associated with increased axial lengthinduced retinal stretching. 展开更多
关键词 adaptive optics scanning laser ophthalmoscopy photoreceptor cell packing density FOVEA refractive error MYOPIA
原文传递
Three-Dimensional Reconstruction and Comparison of Three Tuna Species’Fish Body Structures Based on CT Scanning
19
作者 SONG Liming ZHU Mingshan +1 位作者 ZHOU Zihan LI Yuwei 《Journal of Ocean University of China》 2025年第5期1341-1350,共10页
To better understand the biological structure of bigeye tuna(Thunnus obesus),albacore tuna(Thunnus alalunga),and longtail tuna(Thunnus tonggol),computed tomography(CT)was used to scan their bodies,and the data are pro... To better understand the biological structure of bigeye tuna(Thunnus obesus),albacore tuna(Thunnus alalunga),and longtail tuna(Thunnus tonggol),computed tomography(CT)was used to scan their bodies,and the data are processed by Mimics software.The skeleton,swim bladder,and muscle of the three tuna species are reconstructed in three dimensions.The surface area and volume of the corresponding parts are measured.The results show that the surface areas of the skeleton of longtail tuna,bigeye tuna,albacore tuna accounted for 28.18%,37.34%,33.45%of their whole body surface areas respectively;the surface areas of swim bladder accounted for 0,2.06%,2.72% of their whole body surface area respectively;and the surface areas of muscle accounted for 71.82%,60.6%,63.83%of their whole body surface areas respectively.And the volumes of skeleton accounted for 28.18%,8.05%,3.84%,the volumes of swim bladder accounted for 0,3.44%,0.92%,and the volumes of muscle accounted for 94.84%,88.51%,95.24%of their body volumes respectively.The swim bladder of the longtail tuna has degenerated,while that of the bigeye tuna is conical,exhibiting the highest volume proportion among the three species.In contrast,the swim bladder of the albacore tuna is both flat and elongated,resembling an arc.Additionally,the surface area and the volume of the bigeye tuna’s swim bladder differ signifi-cantly from those of the albacore tuna.Regarding skeletal and muscular structures,the bigeye tuna has the highest skeletal volume proportion(8.05%),whereas the albacore tuna exhibits the highest muscle volume proportion(95.24%).These morphological differences are closely associated with their respective habitats.This study demonstrates the potential of CT technology in fish morphological research,providing a reliable,non-invasive method for analyzing internal structures,quantifying organ characteristics and improving the accuracy of acoustic stock assessment. 展开更多
关键词 bigeye tuna albacore tuna longtail tuna CT scan 3D reconstruction mimics software
在线阅读 下载PDF
High-precision laser monitoring system with enhanced non-uniform scanning for railway safety
20
作者 Yingying Yang Cheng Wang +6 位作者 Xiaoqi Liu Yu Liu Weier Lu Zhonglin Zhu Hongye Yan Guotang Zhao Xuechun Lin 《Railway Engineering Science》 2025年第1期79-93,共15页
The intrusion of obstacles onto railway tracks presents a significant threat to train safety,characterized by sudden and unpredictable occurrences.With China leading the world in high-speed rail mileage,ensuring railw... The intrusion of obstacles onto railway tracks presents a significant threat to train safety,characterized by sudden and unpredictable occurrences.With China leading the world in high-speed rail mileage,ensuring railway security is paramount.The current laser monitoring technologies suffer from high false alarm rates and unreliable intrusion identification.This study addresses these issues by investigating high-resolution laser monitoring technology for railway obstacles,focusing on key parameters such as monitoring range and resolution.We propose an enhanced non-uniform laser scanning method,developing a laser monitoring system that reduces the obstacle false alarm rate to 2.00%,significantly lower than the 20%standard(TJ/GW135-2015).This rate is the best record for laser monitoring systems on China Railway.Our system operates seamlessly in all weather conditions,providing superior accuracy,resolution,and identification efficiency.It is the only 3D LiDAR system certified by the China State Railway Group Co.,Ltd.(Certificate No.[2023]008).Over three years,our system has been deployed at numerous points along various lines managed by the China State Railway Group,accumulating a dataset of 300,000 observations.This extensive deployment has significantly enhanced railway safety.The development and implementation of our railway laser monitoring system represent a substantial advancement in railway safety technology.Its low false alarm rate(2.00%),high accuracy(20 cm×20 cm×20 cm),and robust performance in diverse conditions underscore its potential for widespread adoption,promising to enhance railway safety in China and internationally. 展开更多
关键词 Laser monitoring technology Non-uniform laser scanning method False alarm rate Railway safety
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部