We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can rand...We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can randomly output the signal in 25 ns. The design is based on true random number generator (TRNG). Considering the electrical connection between the TGC source and the developing trigger electronics, the GFZ connector is used. The experimental results show that the improved TGC simulation signal source can uniformly output the random signal in every channel. The output noise is less than 3 mVrms.展开更多
Abstract: Position-sensitive thin-gap gas detectors have been developed in the laboratory, based on the ATLAS Thin Gap Chamber. The signal collection structure has been redesigned while retaining other configurations...Abstract: Position-sensitive thin-gap gas detectors have been developed in the laboratory, based on the ATLAS Thin Gap Chamber. The signal collection structure has been redesigned while retaining other configurations to keep the good time performance of the detector. The position resolution was measured using cosmic muons for two versions of the detector and found to be 409 μm and 233 μm respectively. This paper presents the structure of these two detector prototypes, with the position resolution measurement method and results.展开更多
基金Supported by the State Key Laboratory of Particle Detection and Electronicsthe National Natural Science Foundation of China under Grant No 11375179
文摘We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can randomly output the signal in 25 ns. The design is based on true random number generator (TRNG). Considering the electrical connection between the TGC source and the developing trigger electronics, the GFZ connector is used. The experimental results show that the improved TGC simulation signal source can uniformly output the random signal in every channel. The output noise is less than 3 mVrms.
基金Supported by NSFC(11075095)Shandong Province Science Foundation(ZR2010AM015)
文摘Abstract: Position-sensitive thin-gap gas detectors have been developed in the laboratory, based on the ATLAS Thin Gap Chamber. The signal collection structure has been redesigned while retaining other configurations to keep the good time performance of the detector. The position resolution was measured using cosmic muons for two versions of the detector and found to be 409 μm and 233 μm respectively. This paper presents the structure of these two detector prototypes, with the position resolution measurement method and results.