期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
TAESS在煤多联产系统热经济分析中的应用
1
作者 张夏博 俞自涛 +3 位作者 胡亚才 沈佐湘 岑建孟 方梦祥 《能源工程》 2008年第3期50-54,共5页
采用能量系统热经济分析软件(TAESS)对75t/h循环流化床煤多联产能源系统进行了热经济分析,得到了系统组元的产品单位成本,并分析了系统组元产品单位成本的分布形成过程。得出煤多联产系统效率为58.64%,锅炉、净化系统和汽轮发电... 采用能量系统热经济分析软件(TAESS)对75t/h循环流化床煤多联产能源系统进行了热经济分析,得到了系统组元的产品单位成本,并分析了系统组元产品单位成本的分布形成过程。得出煤多联产系统效率为58.64%,锅炉、净化系统和汽轮发电机组等组元是挖掘提高运行效率潜力的主要部件。产品成本分析对于系统运行状况评价、终端产品定价、优化设计以及故障诊断将提供重要参考。 展开更多
关键词 热经济 多联产 taess
在线阅读 下载PDF
A textile-based alignment-free electrophysiological sensing sleeve for comprehensive cardiovascular monitoring
2
作者 Shirong Qiu Yihao Li +7 位作者 Chengkai Dai Shun Wu Xiangjia Chen Nan Ji Guoxin Fang Yeung Yam Charlie C.L.Wang Ni Zhao 《Microsystems & Nanoengineering》 2025年第6期313-323,共11页
Continuous monitoring of cardiovascular risk factors in daily life is crucial for disease prevention and management.Current wearable systems,such as photoplethysmography(PPG),ultrasound,and pressure sensors,can captur... Continuous monitoring of cardiovascular risk factors in daily life is crucial for disease prevention and management.Current wearable systems,such as photoplethysmography(PPG),ultrasound,and pressure sensors,can capture some of these parameters but require precise sensor alignment over arteries.This alignment dependency complicates daily use and makes the signals highly susceptible to motion artifacts.In this work,we present a textile-based alignmentfree electrophysiological sensing sleeve(TAESS)that can be comfortably worn on the upper arm.The TAESS integrates impedance plethysmography(IPG)and electrocardiography(ECG)to enable synchronized cardiovascular haemodynamic monitoring,including blood pressure(BP),cardiac output(CO),systemic vascular resistance(SVR),heart rate(HR),and other metrics.The sleeve is fabricated using silver-based conductive yarns,forming flexible,breathable,and stretchable electrodes that are produced via an automated,low-cost knitting process.Compared to commercial electrodes,TAESS demonstrates superior permeability(37.5 mg·cm^(-2)·h^(-1)),stretchability(exceeding 45%in wale direction),and thermal regulation(remaining within 0.4℃after exercise).Most importantly,it maintains high signal fidelity and is minimally affected by radial movements,outperforming commercial PPG sensors in blood volume detection.The TAESS achieved systolic and diastolic BP prediction root-mean-squared errors of 7.05mmHg and 5.93 mmHg,respectively,even under respiratory interference and after re-wearing.This scalable,low-cost sensing sleeve offers a robust and alignment-free solution for continuous cardiovascular monitoring,paving the way for personalized healthcare in daily life. 展开更多
关键词 sensor alignment pressure sensorscan electrophysiological monitoring disease prevention wearable systemssuch alignment free electrophysiological sensing sleeve taess textile based sensing
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部