Passive surface wave imaging has been a powerful tool for near-surface characterization in urban areas,which extracts surface wave signals from ambient seismic noise and then estimates subsurface shear wave velocity b...Passive surface wave imaging has been a powerful tool for near-surface characterization in urban areas,which extracts surface wave signals from ambient seismic noise and then estimates subsurface shear wave velocity by inversion of the measured phase velocity.The high-frequency(approximately>1 Hz)seismic noise fields in urban environments are dominantly induced by human activities such as the vehicle traffic.Traffic seismic sources are nonrandomly distributed in time and space.Applying standard interferometric techniques to recordings from these nonrandom noise sources makes the Green’s function liable to estimation errors.We analyze the influence of using nonrandom traffic seismic sources for surface wave imaging.With nonrandom traffic seismic sources in time,spurious signals are generated in the cross-correlation function.With nonrandom traffic seismic sources in space,surface-wave phase velocities could be overestimated in the dispersion measurement.We provide an overview of solutions for surface-wave imaging with nonrandom traffic seismic sources in time and space,aiming to improve the retrieval of high-frequency surface waves and achieve reliable results from ultrashort(tens of seconds)observations for near-surface characterization.展开更多
Overt and harmful diabetes mellitus(DM)has detrimental effects on individuals and,by extension,the community.Among the microvascular DM complications is diabetic retinopathy(DR).DR may cause irreversible vision deteri...Overt and harmful diabetes mellitus(DM)has detrimental effects on individuals and,by extension,the community.Among the microvascular DM complications is diabetic retinopathy(DR).DR may cause irreversible vision deterioration in cases of poor blood glucose regulation.Changes in vascular permeability are key trigger points for diabetic macular edema(DME),a condition characterized by the accumulation of fluid in the macula.The development of vascular endothelial growth factor(VEGF)pathway inhibitors has provided a pathogenesis-based treatment approach for DME.Optical coherence tomography(OCT)provides highresolution imaging of the anatomy,including the aging of DME and its structural damage,in distinct morphologic subtypes of macular edema,thereby supporting the assessment of macular edema treatment.The availability of repeated OCT monitoring provides clinical reassurance through the treatment.OCT angiography(OCTA)provides retinal blood flow maps with high spatial resolution.The ability promotes an understanding of disease pathogenesis and facilitates the implementation of new therapeutic methods.This review compares the potential of OCT and OCTA in the diagnosis and treatment of DME,as well as their respective therapeutic applications.展开更多
Photoacoustic-computed tomography is a novel imaging technique that combines high absorption contrast and deep tissue penetration capability,enabling comprehensive three-dimensional imaging of biological targets.Howev...Photoacoustic-computed tomography is a novel imaging technique that combines high absorption contrast and deep tissue penetration capability,enabling comprehensive three-dimensional imaging of biological targets.However,the increasing demand for higher resolution and real-time imaging results in significant data volume,limiting data storage,transmission and processing efficiency of system.Therefore,there is an urgent need for an effective method to compress the raw data without compromising image quality.This paper presents a photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer.This method is based on the cooperative compression framework that integrates wavelet hard coding with deep learning-based soft decoding.It combines the multiscale analysis capability of wavelet transforms with the global feature modeling advantage of Transformers,achieving high-quality data compression and reconstruction.Experimental results using k-wave simulation suggest that the proposed compression system has advantages under extreme compression conditions,achieving a raw data compression ratio of up to 1:40.Furthermore,three-dimensional data compression experiment using in vivo mouse demonstrated that the maximum peak signal-to-noise ratio(PSNR)and structural similarity index(SSIM)values of reconstructed images reached 38.60 and 0.9583,effectively overcoming detail loss and artifacts introduced by raw data compression.All the results suggest that the proposed system can significantly reduce storage requirements and hardware cost,enhancing computational efficiency and image quality.These advantages support the development of photoacoustic-computed tomography toward higher efficiency,real-time performance and intelligent functionality.展开更多
This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both commo...This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification.展开更多
Gastric cancer,including stomach tumors,poses significant health challenges due to late-stage diagnosis and limited early detection methods.Accurate imaging and precise tumor margin demarcation are critical for effect...Gastric cancer,including stomach tumors,poses significant health challenges due to late-stage diagnosis and limited early detection methods.Accurate imaging and precise tumor margin demarcation are critical for effective treatment planning and improved patient outcomes.Conventional imaging techniques,such as endoscopy and histopathology,provide valuable diagnostic information but cannot offer real-time assessment.We aim to explore the application of optical coherence tomography(OCT),combined with statistical and machine learning methods,for rapid tumor margin demarcation in gastrointestinal(GI)cancer tissues in exvivo.GI tumor specimens from 17 patients were imaged intraoperatively with OCT.Quantitative features were extracted from the images,and statistical and machine learning analyses were applied to distinguish tissue types.Subsequent histopathological evaluation was used as the reference standard for validation.The combination of OCT imaging and data-driven analysis enables clear differentiation between healthy,marginal and tumor tissues in near real-time.The KNN model achieved the highest classification accuracy(0.921±0.040),with SVM(0.906±0.038)and Extra Trees(0.901±0.034)also demonstrating robust performance in discriminating tissue margins.OCT findings demonstrate strong agreement with histopathology.Integrated with statistical and machine learning techniques,OCT enables rapid assessment of GI tumor margins.This approach provides quantitative objectivity and real-time feedback,closely approximating histopathological analysis and supporting improved surgical decision-making.展开更多
Background:Diabetic macular edema is a prevalent retinal condition and a leading cause of visual impairment among diabetic patients’Early detection of affected areas is beneficial for effective diagnosis and treatmen...Background:Diabetic macular edema is a prevalent retinal condition and a leading cause of visual impairment among diabetic patients’Early detection of affected areas is beneficial for effective diagnosis and treatment.Traditionally,diagnosis relies on optical coherence tomography imaging technology interpreted by ophthalmologists.However,this manual image interpretation is often slow and subjective.Therefore,developing automated segmentation for macular edema images is essential to enhance to improve the diagnosis efficiency and accuracy.Methods:In order to improve clinical diagnostic efficiency and accuracy,we proposed a SegNet network structure integrated with a convolutional block attention module(CBAM).This network introduces a multi-scale input module,the CBAM attention mechanism,and jump connection.The multi-scale input module enhances the network’s perceptual capabilities,while the lightweight CBAM effectively fuses relevant features across channels and spatial dimensions,allowing for better learning of varying information levels.Results:Experimental results demonstrate that the proposed network achieves an IoU of 80.127%and an accuracy of 99.162%.Compared to the traditional segmentation network,this model has fewer parameters,faster training and testing speed,and superior performance on semantic segmentation tasks,indicating its highly practical applicability.Conclusion:The C-SegNet proposed in this study enables accurate segmentation of Diabetic macular edema lesion images,which facilitates quicker diagnosis for healthcare professionals.展开更多
The Urumqi foreland thrust tectonic belt exhibits complex geological structures and strong seismicity.Imaging its shallow crustal structure is of great significance for understanding its tectonic mechanism and seismog...The Urumqi foreland thrust tectonic belt exhibits complex geological structures and strong seismicity.Imaging its shallow crustal structure is of great significance for understanding its tectonic mechanism and seismogenic environment.We obtained a high-resolution S-wave velocity model of the shallow crust at depths of 0–8 km using ambient noise tomography applied to data from a dense seismic array.Sediments are generally thinner in the southeast and thicker in the northwest,with a maximum thickness of more than 8 km.Variations in the velocity structure near the Xishan,Wanyaogou,and Yamalike faults indicate that their formation was related to differences in the physical properties on either side of the fault.In addition,the faults exhibit thrusting of the low-velocity sides towards the high-velocity sides.In the study area,earthquakes rarely occur at depths of less than 3 km and are mostly concentrated in the high-velocity zone in the southern part.Below 3 km depth,more earthquakes were observed,mainly distributed near faults or in relatively high-velocity areas in the southern part.This suggests that high-velocity structures are more prone to stress accumulation,resulting in earthquakes.At 6–8 km depth,the densely distributed earthquakes in the northwestern part of the Bogda mountains are well-aligned with the northwest-oriented low-velocity zone observed in this study,suggesting that this weak zone likely controls seismicity in this area.展开更多
BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector compu...BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector computed tomography(MDCT)and gastrointestinal endoscopy for GC screening,preoperative staging,and lymph node metastasis detection,thereby providing a reference for clinical diagnosis and treatment.METHODS In this retrospective study clinical and imaging data of 134 patients with suspected GC who were admitted between January 2023 and October 2024 were initially reviewed.According to the inclusion and exclusion criteria,102 patients were finally enrolled in the analysis.All enrolled patients had undergone both MDCT and gastrointestinal endoscopy examinations prior to surgical intervention.Preoperative clinical staging and lymph node metastasis findings were compared with pathological results.RESULTS The combined use of MDCT and gastrointestinal endoscopy demonstrated a sensitivity of 98.53%,specificity of 97.06%,accuracy of 98.04%,positive predictive value of 98.53%,and negative predictive value of 97.06%for diagnosing GC.These factors were all significantly higher than those of MDCT or endoscopy alone(P<0.05).The accuracy rates of the combined approach for detecting clinical T and N stages were 97.06%and 92.65%,respectively,outperforming MDCT alone(86.76% and 79.41%)and endoscopy alone(85.29% and 70.59%)(P<0.05).Among 68 patients with confirmed GC,50(73.53%)were pathologically diagnosed with lymph node metastasis.The accuracy for detecting lymph node metastasis was 66.00%with endoscopy,76.00%with MDCT,and 92.00% with the combined approach,all with statistically significant differences(P<0.05).CONCLUSION The combined application of MDCT and gastrointestinal endoscopy enhanced diagnostic accuracy for GC,provided greater consistency in preoperative staging,and improved the detection of lymph node metastasis,thereby demonstrating significant clinical utility.展开更多
BACKGROUND:Individualized positive end-expiratory pressure(PEEP)titration is a crucial technique in mechanical ventilation therapy for acute respiratory distress syndrome(ARDS)patients with intra-abdominal hypertensio...BACKGROUND:Individualized positive end-expiratory pressure(PEEP)titration is a crucial technique in mechanical ventilation therapy for acute respiratory distress syndrome(ARDS)patients with intra-abdominal hypertension(IAH).This study aimed to evaluate the eff ectiveness of electrical impedance tomography(EIT)-guided PEEP titration in this population.METHODS:This prospective study enrolled 36 ARDS patients,including 22 patients with IAH and 14 without IAH.All the patients underwent EIT-guided PEEP titration at the intersection point between alveolar overdistension and collapse during a decremental PEEP trial.The changes in pulmonary ventilation distribution,respiratory mechanics and hemodynamics during the titration process were observed.RESULTS:After EIT-guided PEEP titration was performed,the PEEP,peak inspiratory pressure and plateau pressure increased significantly(P<0.05).Furthermore,no significant differences were observed in respiratory system compliance,tidal volume,driving pressure,or the 4*DP+RR index between the two groups(P>0.05).The mechanical power increased in the non-IAH(NIAH)group after PEEP titration(P<0.05).Ventilation in gravity-dependent lung regions significantly increased(P<0.05),and the oxygenation index(PaO2/FiO2)improved signifi cantly(P<0.05)in both groups.However,blood pressure,heart rate,respiratory rate,central venous pressure,and lactate levels did not signifi cantly change.In the IAH group,the PaO2/FiO2 ratio improved less than that in the NIAH group did(P<0.05).CONCLUSION:In our study,individualized PEEP titration guided by EIT improved oxygenation in ARDS patients with concomitant IAH without signifi cantly aff ecting hemodynamics.The presence of IAH may limit the improvement of oxygenation during EIT-guided PEEP titration.展开更多
AIM:To investigate the effects of chronic alcohol consumption on retinal microcirculation by comparing different alcohol-consuming groups using optical coherence tomography(OCT)and OCT angiography(OCTA).METHODS:This o...AIM:To investigate the effects of chronic alcohol consumption on retinal microcirculation by comparing different alcohol-consuming groups using optical coherence tomography(OCT)and OCT angiography(OCTA).METHODS:This observational clinical study utilized a cross-sectional and prospective design,focusing on chronic alcohol consumers alongside a non-consuming control group.OCT/OCTA imaging parameters including central retinal subfield thickness(CST),subfoveal choroidal thickness(SCT),foveal avascular zone(FAZ)and vessel density(VD)in the superficial and deep capillary plexuses in both the macular and optic disc(OD)regions were recorded.Data were analyzed using SPSS 15.0;descriptive statistics were reported,group comparisons were performed with Chisquare,Kruskal–Wallis,and Bonferroni-corrected Mann–Whitney U tests,and relationships were assessed using Spearman correlation,with statistical significance set at P<0.05.RESULTS:A total of 160 eyes of 160 participants(110 females and 50 males with mean age 38.7±9.9y)who don’t smoke were divided into five groups:never,occasional,monthly,weekly and daily drinkers.The mean CST was 216.6±14.2μm and the mean SCT was 358.9±84.5μm.There was no statistically significantly difference in CST and SCT among the groups(P=0.890,0.799).Foveal superficial capillary plexuses(SCPs)VD was higher in monthly drinkers compared to occasional drinkers(P=0.015).Foveal VD in deep capillary plexus was also higher in monthly drinkers than in never and occasional drinkers(P=0.004,0.006).Nasal SCPs VD at the OD was higher in monthly drinkers compared to never drinkers(P=0.005).There was no significant difference FAZ area among the groups(P=0.071).CONCLUSION:Both superficial and deep microvascular structures in the inferior quadrants of macula are positively correlated with frequency of alcohol use.Also in our study results is that the monthly drinker group has uniquely higher VDs in both macula and OD.This leads us to consider moderate alcohol consumption may also have protective effects on retinal microcirculation.展开更多
Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance to...Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke.展开更多
The principle of surface wave plasma discharge in a rectangular cavity is introduced and the distribution of the electromagnetic field within a rectangular waveguide is analysed. A novel structure of a slot antenna ar...The principle of surface wave plasma discharge in a rectangular cavity is introduced and the distribution of the electromagnetic field within a rectangular waveguide is analysed. A novel structure of a slot antenna array is presented. In comparison with the traditional slotantenna, it is shown that the designed slot antenna array can excite effectively the surface wave coupling into the chamber, and generate a stable large-area high-density plasma. These results are useful for exploring the optimized design of the slot-antenna for surface wave plasmas.展开更多
A three-dimensional model of a surface-wave plasma (SWP) source is built numerically using the finite-difference time-domain (FDTD) method to investigate the structure of the surface wave propagation along the pla...A three-dimensional model of a surface-wave plasma (SWP) source is built numerically using the finite-difference time-domain (FDTD) method to investigate the structure of the surface wave propagation along the plasma-dielectric interface and the distributions of electromagnetic fields in the whole system. A good-performance excitation source technique for the waveguide which is pivotal to the simulation is presented. The technique can avoid the dc distortions of magnetic fields caused by the forcing electric wall. An example of simulation is given to confirm the existence of the surface waves. The simulation also shows that the code developed is a useful tool in the computer-aided design of the antenna of the SWP source.展开更多
Surface-wave inversion is a powerful tool for revealing the Earth's internal structure.However,aside from shear-wave velocity(v_(S)),other parameters can influence the inversion outcomes,yet these have not been sy...Surface-wave inversion is a powerful tool for revealing the Earth's internal structure.However,aside from shear-wave velocity(v_(S)),other parameters can influence the inversion outcomes,yet these have not been systematically discussed.This study investigates the influence of various parameter assumptions on the results of surface-wave inversion,including the compressional and shear velocity ratio(v_(P)/v_(S)),shear-wave attenuation(Q_(S)),density(ρ),Moho interface,and sedimentary layer.We constructed synthetic models to generate dispersion data and compared the obtained results with different parameter assumptions with those of the true model.The results indicate that the v_(P)/v_(S) ratio,Q_(S),and density(ρ) have minimal effects on absolute velocity values and perturbation patterns in the inversion.Conversely,assumptions about the Moho interface and sedimentary layer significantly influenced absolute velocity values and perturbation patterns.Introducing an erroneous Mohointerface depth in the initial model of the inversion significantly affected the v_(S) model near that depth,while using a smooth initial model results in relatively minor deviations.The assumption on the sedimentary layer not only affects shallow structure results but also impacts the result at greater depths.Non-linear inversion methods outperform linear inversion methods,particularly for the assumptions of the Moho interface and sedimentary layer.Joint inversion with other data types,such as receiver functions or Rayleigh wave ellipticity,and using data from a broader period range or higher-mode surface waves,can mitigate these deviations.Furthermore,incorporating more accurate prior information can improve inversion results.展开更多
Site engineering seismic survey provides basic data for seismic effect analysis. As an important parameter of soil, shear-wave velocity is usually obtained through wave velocity testing in borehole. In this paper, the...Site engineering seismic survey provides basic data for seismic effect analysis. As an important parameter of soil, shear-wave velocity is usually obtained through wave velocity testing in borehole. In this paper, the passive source surface-wave method is introduced into the site engineering seismic survey and practically applied in an engineering site of Shijingshan District. By recording the ubiquitous weak vibration on the earth surface, extract the dispersion curve from the surface-wave components using the SPAC method and obtain the shear-wave velocity structure from inversion. Over the depth of 42 m under- ground, it totally consists of five layers with interface depth of 3.31, 4.50, 7.23, 17.41, and 42.00 m; and shear-wave velocity of 144.0, 198.3, 339.4, 744.2, and 903.7 m/s, respectively. The inversion result is used to evaluate site classification, determine the maximum shear modulus of soil, provide basis for further seismic hazard analysis and site assessment or site zoning, etc. The result shows that the passive source surface-wave method is feasible in the site engineering seismic survey and can replace boreholes,shorten survey period, and reduce engineering cost to some extent.展开更多
The plasma parameters of planar-type surface-wave plasmas (SWPs) are diagnosed based on the resonant excitation of surface plasmon polaritons (SPPs). The plasma parameter distributions are obtained by changing the...The plasma parameters of planar-type surface-wave plasmas (SWPs) are diagnosed based on the resonant excitation of surface plasmon polaritons (SPPs). The plasma parameter distributions are obtained by changing the discharge conditions of gas pressure and incident power. The measured experimental results show that the plasma near the heating layer is excited by surface waves of SPPs while the plasma located downstream originates from diffusion Moreover, the influence of high-frequency oscillations plays a significant role in producing the proposed SWPs with bi-Maxwellian electron energy distributions.展开更多
Surface-wave tomography is an important and widely used method for imaging the crust and upper mantle velocity structure of the Earth.In this study,we proposed a deep learning(DL)method based on convolutional neural n...Surface-wave tomography is an important and widely used method for imaging the crust and upper mantle velocity structure of the Earth.In this study,we proposed a deep learning(DL)method based on convolutional neural network(CNN),named SfNet,to derive the vS model from the Rayleigh wave phase and group velocity dispersion curves.Training a network model usually requires large amount of training datasets,which is labor-intensive and expensive to acquire.Here we relied on synthetics generated automatically from various spline-based vS models instead of directly using the existing vS models of an area to build the training dataset,which enhances the generalization of the DL method.In addition,we used a random sampling strategy of the dispersion periods in the training dataset,which alleviates the problem that the real data used must be sampled strictly according to the periods of training dataset.Tests using synthetic data demonstrate that the proposed method is much faster,and the results for the vS model are more accurate and robust than those of conventional methods.We applied our method to a dataset for the Chinese mainland and obtained a new reference velocity model of the Chinese continent(ChinaVs-DL1.0),which has smaller dispersion misfits than those from the traditional method.The high accuracy and efficiency of our DL approach makes it an important method for vS model inversions from large amounts of surface-wave dispersion data.展开更多
The basic equations of free capillary_gravity surface_waves in a circular cylindrical basin were derived from Luke's principle. Taking Galerkin's expansion of the velocity potential and the free surface elevat...The basic equations of free capillary_gravity surface_waves in a circular cylindrical basin were derived from Luke's principle. Taking Galerkin's expansion of the velocity potential and the free surface elevation, the second_order perturbation equations were derived by use of expansion of multiple scale. The nonlinear interactions with the second order internal resonance of three free surface_waves were discussed based on the above. The results include:derivation of the couple equations of resonant interactions among three waves and the conservation laws; analysis of the positions of equilibrium points in phase plane; study of the resonant parameters and the non_resonant parameters respectively in all kinds of circumstances; derivation of the stationary solutions of the second_order interaction equations corresponding to different parameters and analysis of the stability property of the solutions; discussion of the effective solutions only in the limited time range. The analysis makes it clear that the energy transformation mode among three waves differs because of the different initial conditions under nontrivial circumstance. The energy may either exchange among three waves periodically or damp or increase in single waves.展开更多
We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast canc...We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast cancer cells which expressed redfluorescent protein(RFP).For FMT system,reflective illumination mode was adopted with full-angle data acquisition.[18F]-Fluorodeoxyglucose([18F]-FDG)was used as radioactive tracer for PET.Both data were acquired simultaneously and then reconstructed separately before fusion.Fluorescent tomography results showed exactly where the tumor was located while PET results offered more metabolic information.Results confirmed feasibility for tumor detection and showed superiority to single modality imaging.展开更多
Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible ligh...Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible light,whereas PCCT utilizes photon-counting detectors that directly transform X-ray photons into electric signals.This direct conversion allows photon-counting detectors to sort photons into discrete energy levels,thereby enhancing image quality through superior noise reduction,improved spatial and contrast resolution,and reduced artifacts.In pediatric applications,PCCT offers substantial benefits,including lower radiation doses,which may help reduce the risk of malignancy in pediatric patients,with perhaps greater potential to benefit those with repeated exposure from a young age.Enhanced spatial resolution facilitates better visualization of small structures,vital for diagnosing congenital heart defects.Additionally,PCCT’s spectral capabilities improve tissue characterization and enable the creation of virtual monoenergetic images,which enhance soft-tissue contrast and potentially reduce contrast media doses.Initial clinical results indicate that PCCT provides superior image quality and diagnostic accuracy compared to conven-tional CT,particularly in challenging pediatric cardiovascular cases.As PCCT technology matures,further research and standardized protocols will be essential to fully integrate it into pediatric imaging practices,ensuring optimized diagnostic outcomes and patient safety.展开更多
基金supported by the National Natural Science Foundation of China(No.42374177)。
文摘Passive surface wave imaging has been a powerful tool for near-surface characterization in urban areas,which extracts surface wave signals from ambient seismic noise and then estimates subsurface shear wave velocity by inversion of the measured phase velocity.The high-frequency(approximately>1 Hz)seismic noise fields in urban environments are dominantly induced by human activities such as the vehicle traffic.Traffic seismic sources are nonrandomly distributed in time and space.Applying standard interferometric techniques to recordings from these nonrandom noise sources makes the Green’s function liable to estimation errors.We analyze the influence of using nonrandom traffic seismic sources for surface wave imaging.With nonrandom traffic seismic sources in time,spurious signals are generated in the cross-correlation function.With nonrandom traffic seismic sources in space,surface-wave phase velocities could be overestimated in the dispersion measurement.We provide an overview of solutions for surface-wave imaging with nonrandom traffic seismic sources in time and space,aiming to improve the retrieval of high-frequency surface waves and achieve reliable results from ultrashort(tens of seconds)observations for near-surface characterization.
文摘Overt and harmful diabetes mellitus(DM)has detrimental effects on individuals and,by extension,the community.Among the microvascular DM complications is diabetic retinopathy(DR).DR may cause irreversible vision deterioration in cases of poor blood glucose regulation.Changes in vascular permeability are key trigger points for diabetic macular edema(DME),a condition characterized by the accumulation of fluid in the macula.The development of vascular endothelial growth factor(VEGF)pathway inhibitors has provided a pathogenesis-based treatment approach for DME.Optical coherence tomography(OCT)provides highresolution imaging of the anatomy,including the aging of DME and its structural damage,in distinct morphologic subtypes of macular edema,thereby supporting the assessment of macular edema treatment.The availability of repeated OCT monitoring provides clinical reassurance through the treatment.OCT angiography(OCTA)provides retinal blood flow maps with high spatial resolution.The ability promotes an understanding of disease pathogenesis and facilitates the implementation of new therapeutic methods.This review compares the potential of OCT and OCTA in the diagnosis and treatment of DME,as well as their respective therapeutic applications.
基金supported by the National Key R&D Program of China[Grant No.2023YFF0713600]the National Natural Science Foundation of China[Grant No.62275062]+3 种基金Project of Shandong Innovation and Startup Community of High-end Medical Apparatus and Instruments[Grant No.2023-SGTTXM-002 and 2024-SGTTXM-005]the Shandong Province Technology Innovation Guidance Plan(Central Leading Local Science and Technology Development Fund)[Grant No.YDZX2023115]the Taishan Scholar Special Funding Project of Shandong Provincethe Shandong Laboratory of Advanced Biomaterials and Medical Devices in Weihai[Grant No.ZL202402].
文摘Photoacoustic-computed tomography is a novel imaging technique that combines high absorption contrast and deep tissue penetration capability,enabling comprehensive three-dimensional imaging of biological targets.However,the increasing demand for higher resolution and real-time imaging results in significant data volume,limiting data storage,transmission and processing efficiency of system.Therefore,there is an urgent need for an effective method to compress the raw data without compromising image quality.This paper presents a photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer.This method is based on the cooperative compression framework that integrates wavelet hard coding with deep learning-based soft decoding.It combines the multiscale analysis capability of wavelet transforms with the global feature modeling advantage of Transformers,achieving high-quality data compression and reconstruction.Experimental results using k-wave simulation suggest that the proposed compression system has advantages under extreme compression conditions,achieving a raw data compression ratio of up to 1:40.Furthermore,three-dimensional data compression experiment using in vivo mouse demonstrated that the maximum peak signal-to-noise ratio(PSNR)and structural similarity index(SSIM)values of reconstructed images reached 38.60 and 0.9583,effectively overcoming detail loss and artifacts introduced by raw data compression.All the results suggest that the proposed system can significantly reduce storage requirements and hardware cost,enhancing computational efficiency and image quality.These advantages support the development of photoacoustic-computed tomography toward higher efficiency,real-time performance and intelligent functionality.
基金Project(2023YFB4606200)supported by the National Key Research and Development Program of ChinaProject(2023-SSRF-HZ-503114-2)supported by Shanghai Synchrotron Radiation Facility,Instrument BL16U2,China。
文摘This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification.
基金supported by the financial support received from the Indian Council of Medical Research-Department of Health Research(ICMRDHR-CoE-5/3/8/5/2019/I-MDMS)Medical Device and Diagnostics Mission Secretariat(MDMS)and Foundation for Centre for Healthcare Entrepreneurship(CfHE).
文摘Gastric cancer,including stomach tumors,poses significant health challenges due to late-stage diagnosis and limited early detection methods.Accurate imaging and precise tumor margin demarcation are critical for effective treatment planning and improved patient outcomes.Conventional imaging techniques,such as endoscopy and histopathology,provide valuable diagnostic information but cannot offer real-time assessment.We aim to explore the application of optical coherence tomography(OCT),combined with statistical and machine learning methods,for rapid tumor margin demarcation in gastrointestinal(GI)cancer tissues in exvivo.GI tumor specimens from 17 patients were imaged intraoperatively with OCT.Quantitative features were extracted from the images,and statistical and machine learning analyses were applied to distinguish tissue types.Subsequent histopathological evaluation was used as the reference standard for validation.The combination of OCT imaging and data-driven analysis enables clear differentiation between healthy,marginal and tumor tissues in near real-time.The KNN model achieved the highest classification accuracy(0.921±0.040),with SVM(0.906±0.038)and Extra Trees(0.901±0.034)also demonstrating robust performance in discriminating tissue margins.OCT findings demonstrate strong agreement with histopathology.Integrated with statistical and machine learning techniques,OCT enables rapid assessment of GI tumor margins.This approach provides quantitative objectivity and real-time feedback,closely approximating histopathological analysis and supporting improved surgical decision-making.
基金supported by the Guangdong Pharmaceutical University 2024 Higher Education Research Projects(GKP202403,GMP202402)the Guangdong Pharmaceutical University College Students’Innovation and Entrepreneurship Training Programs(Grant No.202504302033,202504302034,202504302036,and 202504302244).
文摘Background:Diabetic macular edema is a prevalent retinal condition and a leading cause of visual impairment among diabetic patients’Early detection of affected areas is beneficial for effective diagnosis and treatment.Traditionally,diagnosis relies on optical coherence tomography imaging technology interpreted by ophthalmologists.However,this manual image interpretation is often slow and subjective.Therefore,developing automated segmentation for macular edema images is essential to enhance to improve the diagnosis efficiency and accuracy.Methods:In order to improve clinical diagnostic efficiency and accuracy,we proposed a SegNet network structure integrated with a convolutional block attention module(CBAM).This network introduces a multi-scale input module,the CBAM attention mechanism,and jump connection.The multi-scale input module enhances the network’s perceptual capabilities,while the lightweight CBAM effectively fuses relevant features across channels and spatial dimensions,allowing for better learning of varying information levels.Results:Experimental results demonstrate that the proposed network achieves an IoU of 80.127%and an accuracy of 99.162%.Compared to the traditional segmentation network,this model has fewer parameters,faster training and testing speed,and superior performance on semantic segmentation tasks,indicating its highly practical applicability.Conclusion:The C-SegNet proposed in this study enables accurate segmentation of Diabetic macular edema lesion images,which facilitates quicker diagnosis for healthcare professionals.
基金supported by the Key Research and Development Program of the Xinjiang Uygur Autonomous Region(No.2020B03006-1)the National Natural Science Foundation of China(Nos.42304069,and 42102275).
文摘The Urumqi foreland thrust tectonic belt exhibits complex geological structures and strong seismicity.Imaging its shallow crustal structure is of great significance for understanding its tectonic mechanism and seismogenic environment.We obtained a high-resolution S-wave velocity model of the shallow crust at depths of 0–8 km using ambient noise tomography applied to data from a dense seismic array.Sediments are generally thinner in the southeast and thicker in the northwest,with a maximum thickness of more than 8 km.Variations in the velocity structure near the Xishan,Wanyaogou,and Yamalike faults indicate that their formation was related to differences in the physical properties on either side of the fault.In addition,the faults exhibit thrusting of the low-velocity sides towards the high-velocity sides.In the study area,earthquakes rarely occur at depths of less than 3 km and are mostly concentrated in the high-velocity zone in the southern part.Below 3 km depth,more earthquakes were observed,mainly distributed near faults or in relatively high-velocity areas in the southern part.This suggests that high-velocity structures are more prone to stress accumulation,resulting in earthquakes.At 6–8 km depth,the densely distributed earthquakes in the northwestern part of the Bogda mountains are well-aligned with the northwest-oriented low-velocity zone observed in this study,suggesting that this weak zone likely controls seismicity in this area.
文摘BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector computed tomography(MDCT)and gastrointestinal endoscopy for GC screening,preoperative staging,and lymph node metastasis detection,thereby providing a reference for clinical diagnosis and treatment.METHODS In this retrospective study clinical and imaging data of 134 patients with suspected GC who were admitted between January 2023 and October 2024 were initially reviewed.According to the inclusion and exclusion criteria,102 patients were finally enrolled in the analysis.All enrolled patients had undergone both MDCT and gastrointestinal endoscopy examinations prior to surgical intervention.Preoperative clinical staging and lymph node metastasis findings were compared with pathological results.RESULTS The combined use of MDCT and gastrointestinal endoscopy demonstrated a sensitivity of 98.53%,specificity of 97.06%,accuracy of 98.04%,positive predictive value of 98.53%,and negative predictive value of 97.06%for diagnosing GC.These factors were all significantly higher than those of MDCT or endoscopy alone(P<0.05).The accuracy rates of the combined approach for detecting clinical T and N stages were 97.06%and 92.65%,respectively,outperforming MDCT alone(86.76% and 79.41%)and endoscopy alone(85.29% and 70.59%)(P<0.05).Among 68 patients with confirmed GC,50(73.53%)were pathologically diagnosed with lymph node metastasis.The accuracy for detecting lymph node metastasis was 66.00%with endoscopy,76.00%with MDCT,and 92.00% with the combined approach,all with statistically significant differences(P<0.05).CONCLUSION The combined application of MDCT and gastrointestinal endoscopy enhanced diagnostic accuracy for GC,provided greater consistency in preoperative staging,and improved the detection of lymph node metastasis,thereby demonstrating significant clinical utility.
基金PEEP titration in ARDS patients using EIT combined with lung ultrasound,Key Laboratory of Emergency Trauma Research,Ministry of Education (KLET-202201)airway clearance protocol in ICU mechanically ventilated patients based on electrical impedance imaging technology,Natural Science Foundation of Hunan Province (2024JJ9148)effects of end expiratory positive pressure on lung re-expansion in patients with ARDS and intra-abdominal hypertension monitored using lung ultrasound,Natural Science Foundation of Hunan Province (2023JJ60308)
文摘BACKGROUND:Individualized positive end-expiratory pressure(PEEP)titration is a crucial technique in mechanical ventilation therapy for acute respiratory distress syndrome(ARDS)patients with intra-abdominal hypertension(IAH).This study aimed to evaluate the eff ectiveness of electrical impedance tomography(EIT)-guided PEEP titration in this population.METHODS:This prospective study enrolled 36 ARDS patients,including 22 patients with IAH and 14 without IAH.All the patients underwent EIT-guided PEEP titration at the intersection point between alveolar overdistension and collapse during a decremental PEEP trial.The changes in pulmonary ventilation distribution,respiratory mechanics and hemodynamics during the titration process were observed.RESULTS:After EIT-guided PEEP titration was performed,the PEEP,peak inspiratory pressure and plateau pressure increased significantly(P<0.05).Furthermore,no significant differences were observed in respiratory system compliance,tidal volume,driving pressure,or the 4*DP+RR index between the two groups(P>0.05).The mechanical power increased in the non-IAH(NIAH)group after PEEP titration(P<0.05).Ventilation in gravity-dependent lung regions significantly increased(P<0.05),and the oxygenation index(PaO2/FiO2)improved signifi cantly(P<0.05)in both groups.However,blood pressure,heart rate,respiratory rate,central venous pressure,and lactate levels did not signifi cantly change.In the IAH group,the PaO2/FiO2 ratio improved less than that in the NIAH group did(P<0.05).CONCLUSION:In our study,individualized PEEP titration guided by EIT improved oxygenation in ARDS patients with concomitant IAH without signifi cantly aff ecting hemodynamics.The presence of IAH may limit the improvement of oxygenation during EIT-guided PEEP titration.
文摘AIM:To investigate the effects of chronic alcohol consumption on retinal microcirculation by comparing different alcohol-consuming groups using optical coherence tomography(OCT)and OCT angiography(OCTA).METHODS:This observational clinical study utilized a cross-sectional and prospective design,focusing on chronic alcohol consumers alongside a non-consuming control group.OCT/OCTA imaging parameters including central retinal subfield thickness(CST),subfoveal choroidal thickness(SCT),foveal avascular zone(FAZ)and vessel density(VD)in the superficial and deep capillary plexuses in both the macular and optic disc(OD)regions were recorded.Data were analyzed using SPSS 15.0;descriptive statistics were reported,group comparisons were performed with Chisquare,Kruskal–Wallis,and Bonferroni-corrected Mann–Whitney U tests,and relationships were assessed using Spearman correlation,with statistical significance set at P<0.05.RESULTS:A total of 160 eyes of 160 participants(110 females and 50 males with mean age 38.7±9.9y)who don’t smoke were divided into five groups:never,occasional,monthly,weekly and daily drinkers.The mean CST was 216.6±14.2μm and the mean SCT was 358.9±84.5μm.There was no statistically significantly difference in CST and SCT among the groups(P=0.890,0.799).Foveal superficial capillary plexuses(SCPs)VD was higher in monthly drinkers compared to occasional drinkers(P=0.015).Foveal VD in deep capillary plexus was also higher in monthly drinkers than in never and occasional drinkers(P=0.004,0.006).Nasal SCPs VD at the OD was higher in monthly drinkers compared to never drinkers(P=0.005).There was no significant difference FAZ area among the groups(P=0.071).CONCLUSION:Both superficial and deep microvascular structures in the inferior quadrants of macula are positively correlated with frequency of alcohol use.Also in our study results is that the monthly drinker group has uniquely higher VDs in both macula and OD.This leads us to consider moderate alcohol consumption may also have protective effects on retinal microcirculation.
基金supported by the Fundamental Research Funds for the Central Universities,Nos.G2021KY05107,G2021KY05101the National Natural Science Foundation of China,Nos.32071316,32211530049+1 种基金the Natural Science Foundation of Shaanxi Province,No.2022-JM482the Education and Teaching Reform Funds for the Central Universities,No.23GZ230102(all to LL and HH).
文摘Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke.
基金the scientific fund of returnees for studying abroad of the Ministry of Education of China of 2006
文摘The principle of surface wave plasma discharge in a rectangular cavity is introduced and the distribution of the electromagnetic field within a rectangular waveguide is analysed. A novel structure of a slot antenna array is presented. In comparison with the traditional slotantenna, it is shown that the designed slot antenna array can excite effectively the surface wave coupling into the chamber, and generate a stable large-area high-density plasma. These results are useful for exploring the optimized design of the slot-antenna for surface wave plasmas.
文摘A three-dimensional model of a surface-wave plasma (SWP) source is built numerically using the finite-difference time-domain (FDTD) method to investigate the structure of the surface wave propagation along the plasma-dielectric interface and the distributions of electromagnetic fields in the whole system. A good-performance excitation source technique for the waveguide which is pivotal to the simulation is presented. The technique can avoid the dc distortions of magnetic fields caused by the forcing electric wall. An example of simulation is given to confirm the existence of the surface waves. The simulation also shows that the code developed is a useful tool in the computer-aided design of the antenna of the SWP source.
基金supported by the Special Fund of the Institute of Geophysics, China Earthquake Administration (No. DQJB21B32)the National Key R&D Program of China (No. 2022YFF0800601)。
文摘Surface-wave inversion is a powerful tool for revealing the Earth's internal structure.However,aside from shear-wave velocity(v_(S)),other parameters can influence the inversion outcomes,yet these have not been systematically discussed.This study investigates the influence of various parameter assumptions on the results of surface-wave inversion,including the compressional and shear velocity ratio(v_(P)/v_(S)),shear-wave attenuation(Q_(S)),density(ρ),Moho interface,and sedimentary layer.We constructed synthetic models to generate dispersion data and compared the obtained results with different parameter assumptions with those of the true model.The results indicate that the v_(P)/v_(S) ratio,Q_(S),and density(ρ) have minimal effects on absolute velocity values and perturbation patterns in the inversion.Conversely,assumptions about the Moho interface and sedimentary layer significantly influenced absolute velocity values and perturbation patterns.Introducing an erroneous Mohointerface depth in the initial model of the inversion significantly affected the v_(S) model near that depth,while using a smooth initial model results in relatively minor deviations.The assumption on the sedimentary layer not only affects shallow structure results but also impacts the result at greater depths.Non-linear inversion methods outperform linear inversion methods,particularly for the assumptions of the Moho interface and sedimentary layer.Joint inversion with other data types,such as receiver functions or Rayleigh wave ellipticity,and using data from a broader period range or higher-mode surface waves,can mitigate these deviations.Furthermore,incorporating more accurate prior information can improve inversion results.
基金supported by National Natural Science Foundation of China (No. 41174085)Chinese Academy of Sciences (KZZD-EW-TZ-19)China Geological Survey (12120113101400)
文摘Site engineering seismic survey provides basic data for seismic effect analysis. As an important parameter of soil, shear-wave velocity is usually obtained through wave velocity testing in borehole. In this paper, the passive source surface-wave method is introduced into the site engineering seismic survey and practically applied in an engineering site of Shijingshan District. By recording the ubiquitous weak vibration on the earth surface, extract the dispersion curve from the surface-wave components using the SPAC method and obtain the shear-wave velocity structure from inversion. Over the depth of 42 m under- ground, it totally consists of five layers with interface depth of 3.31, 4.50, 7.23, 17.41, and 42.00 m; and shear-wave velocity of 144.0, 198.3, 339.4, 744.2, and 903.7 m/s, respectively. The inversion result is used to evaluate site classification, determine the maximum shear modulus of soil, provide basis for further seismic hazard analysis and site assessment or site zoning, etc. The result shows that the passive source surface-wave method is feasible in the site engineering seismic survey and can replace boreholes,shorten survey period, and reduce engineering cost to some extent.
基金supported by National Natural Science Foundation of China(No.11105002)Doctoral Scientific Research Fund of AUST(No.2010yb011)ITER Domestic Matching Item of China(No.GB105003)
文摘The plasma parameters of planar-type surface-wave plasmas (SWPs) are diagnosed based on the resonant excitation of surface plasmon polaritons (SPPs). The plasma parameter distributions are obtained by changing the discharge conditions of gas pressure and incident power. The measured experimental results show that the plasma near the heating layer is excited by surface waves of SPPs while the plasma located downstream originates from diffusion Moreover, the influence of high-frequency oscillations plays a significant role in producing the proposed SWPs with bi-Maxwellian electron energy distributions.
基金the Open Fund from SinoProbe Laboratory(Grant No.Sinoprobe Lab 202201)the National Natural Science Foundation of China(No.U1939204).
文摘Surface-wave tomography is an important and widely used method for imaging the crust and upper mantle velocity structure of the Earth.In this study,we proposed a deep learning(DL)method based on convolutional neural network(CNN),named SfNet,to derive the vS model from the Rayleigh wave phase and group velocity dispersion curves.Training a network model usually requires large amount of training datasets,which is labor-intensive and expensive to acquire.Here we relied on synthetics generated automatically from various spline-based vS models instead of directly using the existing vS models of an area to build the training dataset,which enhances the generalization of the DL method.In addition,we used a random sampling strategy of the dispersion periods in the training dataset,which alleviates the problem that the real data used must be sampled strictly according to the periods of training dataset.Tests using synthetic data demonstrate that the proposed method is much faster,and the results for the vS model are more accurate and robust than those of conventional methods.We applied our method to a dataset for the Chinese mainland and obtained a new reference velocity model of the Chinese continent(ChinaVs-DL1.0),which has smaller dispersion misfits than those from the traditional method.The high accuracy and efficiency of our DL approach makes it an important method for vS model inversions from large amounts of surface-wave dispersion data.
文摘The basic equations of free capillary_gravity surface_waves in a circular cylindrical basin were derived from Luke's principle. Taking Galerkin's expansion of the velocity potential and the free surface elevation, the second_order perturbation equations were derived by use of expansion of multiple scale. The nonlinear interactions with the second order internal resonance of three free surface_waves were discussed based on the above. The results include:derivation of the couple equations of resonant interactions among three waves and the conservation laws; analysis of the positions of equilibrium points in phase plane; study of the resonant parameters and the non_resonant parameters respectively in all kinds of circumstances; derivation of the stationary solutions of the second_order interaction equations corresponding to different parameters and analysis of the stability property of the solutions; discussion of the effective solutions only in the limited time range. The analysis makes it clear that the energy transformation mode among three waves differs because of the different initial conditions under nontrivial circumstance. The energy may either exchange among three waves periodically or damp or increase in single waves.
基金The authors would like to thank X.Zhang,faculty of XinAoMDT Technology Co.,Ltd.,for the work of system software development.This work is supported by the National Natural Science Foundation of China under Grant Nos.81071191,60831003,30930092,30872633the Tsinghua-Yue-Yuen Medical Science Foundationthe National Basic Research Program of China(973)under Grant No.2011CB707701.
文摘We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast cancer cells which expressed redfluorescent protein(RFP).For FMT system,reflective illumination mode was adopted with full-angle data acquisition.[18F]-Fluorodeoxyglucose([18F]-FDG)was used as radioactive tracer for PET.Both data were acquired simultaneously and then reconstructed separately before fusion.Fluorescent tomography results showed exactly where the tumor was located while PET results offered more metabolic information.Results confirmed feasibility for tumor detection and showed superiority to single modality imaging.
文摘Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible light,whereas PCCT utilizes photon-counting detectors that directly transform X-ray photons into electric signals.This direct conversion allows photon-counting detectors to sort photons into discrete energy levels,thereby enhancing image quality through superior noise reduction,improved spatial and contrast resolution,and reduced artifacts.In pediatric applications,PCCT offers substantial benefits,including lower radiation doses,which may help reduce the risk of malignancy in pediatric patients,with perhaps greater potential to benefit those with repeated exposure from a young age.Enhanced spatial resolution facilitates better visualization of small structures,vital for diagnosing congenital heart defects.Additionally,PCCT’s spectral capabilities improve tissue characterization and enable the creation of virtual monoenergetic images,which enhance soft-tissue contrast and potentially reduce contrast media doses.Initial clinical results indicate that PCCT provides superior image quality and diagnostic accuracy compared to conven-tional CT,particularly in challenging pediatric cardiovascular cases.As PCCT technology matures,further research and standardized protocols will be essential to fully integrate it into pediatric imaging practices,ensuring optimized diagnostic outcomes and patient safety.