期刊文献+
共找到72,874篇文章
< 1 2 250 >
每页显示 20 50 100
Surface-wave imaging with nonrandom traffic seismic sources
1
作者 Binbin Mi Jianghai Xia Hao Zhang 《Earthquake Science》 2025年第3期253-262,共10页
Passive surface wave imaging has been a powerful tool for near-surface characterization in urban areas,which extracts surface wave signals from ambient seismic noise and then estimates subsurface shear wave velocity b... Passive surface wave imaging has been a powerful tool for near-surface characterization in urban areas,which extracts surface wave signals from ambient seismic noise and then estimates subsurface shear wave velocity by inversion of the measured phase velocity.The high-frequency(approximately>1 Hz)seismic noise fields in urban environments are dominantly induced by human activities such as the vehicle traffic.Traffic seismic sources are nonrandomly distributed in time and space.Applying standard interferometric techniques to recordings from these nonrandom noise sources makes the Green’s function liable to estimation errors.We analyze the influence of using nonrandom traffic seismic sources for surface wave imaging.With nonrandom traffic seismic sources in time,spurious signals are generated in the cross-correlation function.With nonrandom traffic seismic sources in space,surface-wave phase velocities could be overestimated in the dispersion measurement.We provide an overview of solutions for surface-wave imaging with nonrandom traffic seismic sources in time and space,aiming to improve the retrieval of high-frequency surface waves and achieve reliable results from ultrashort(tens of seconds)observations for near-surface characterization. 展开更多
关键词 traffic seismic source seismic interferometry surface-wave imaging
在线阅读 下载PDF
Therapeutic approaches to diabetic macular edema assessed using optical coherence tomography and optical coherence tomography angiography
2
作者 Parisa Alsadat Dadkhah Hamed Taheri +14 位作者 Masoud Noroozi Asma Rasouli Zahra Sheikh Saba Imanparvar Saeed Zivari Lashkajani Nahid Samadi Javad Nadem Behzadmehr Amirian Goharsharieh Alishiri Ata Akhtari Kohnehshahri Arshia Shafiei Amirreza Heydarlou Reza Khademi Anahita Rahmati Niloofar Deravi 《International Journal of Ophthalmology(English edition)》 2026年第1期160-174,共15页
Overt and harmful diabetes mellitus(DM)has detrimental effects on individuals and,by extension,the community.Among the microvascular DM complications is diabetic retinopathy(DR).DR may cause irreversible vision deteri... Overt and harmful diabetes mellitus(DM)has detrimental effects on individuals and,by extension,the community.Among the microvascular DM complications is diabetic retinopathy(DR).DR may cause irreversible vision deterioration in cases of poor blood glucose regulation.Changes in vascular permeability are key trigger points for diabetic macular edema(DME),a condition characterized by the accumulation of fluid in the macula.The development of vascular endothelial growth factor(VEGF)pathway inhibitors has provided a pathogenesis-based treatment approach for DME.Optical coherence tomography(OCT)provides highresolution imaging of the anatomy,including the aging of DME and its structural damage,in distinct morphologic subtypes of macular edema,thereby supporting the assessment of macular edema treatment.The availability of repeated OCT monitoring provides clinical reassurance through the treatment.OCT angiography(OCTA)provides retinal blood flow maps with high spatial resolution.The ability promotes an understanding of disease pathogenesis and facilitates the implementation of new therapeutic methods.This review compares the potential of OCT and OCTA in the diagnosis and treatment of DME,as well as their respective therapeutic applications. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography vascular endothelial growth factor
原文传递
Combined multidetector computed tomography and gastrointestinal endoscopy for gastric cancer screening,preoperative staging,and lymph node metastasis detection
3
作者 Le-Ping Ye Yan-Ping Zhang +4 位作者 Gang Chen Yi-Xian Wu Cheng-Long He Dong Wang Qiao Mei 《World Journal of Gastrointestinal Oncology》 2026年第1期200-210,共11页
BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector compu... BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector computed tomography(MDCT)and gastrointestinal endoscopy for GC screening,preoperative staging,and lymph node metastasis detection,thereby providing a reference for clinical diagnosis and treatment.METHODS In this retrospective study clinical and imaging data of 134 patients with suspected GC who were admitted between January 2023 and October 2024 were initially reviewed.According to the inclusion and exclusion criteria,102 patients were finally enrolled in the analysis.All enrolled patients had undergone both MDCT and gastrointestinal endoscopy examinations prior to surgical intervention.Preoperative clinical staging and lymph node metastasis findings were compared with pathological results.RESULTS The combined use of MDCT and gastrointestinal endoscopy demonstrated a sensitivity of 98.53%,specificity of 97.06%,accuracy of 98.04%,positive predictive value of 98.53%,and negative predictive value of 97.06%for diagnosing GC.These factors were all significantly higher than those of MDCT or endoscopy alone(P<0.05).The accuracy rates of the combined approach for detecting clinical T and N stages were 97.06%and 92.65%,respectively,outperforming MDCT alone(86.76% and 79.41%)and endoscopy alone(85.29% and 70.59%)(P<0.05).Among 68 patients with confirmed GC,50(73.53%)were pathologically diagnosed with lymph node metastasis.The accuracy for detecting lymph node metastasis was 66.00%with endoscopy,76.00%with MDCT,and 92.00% with the combined approach,all with statistically significant differences(P<0.05).CONCLUSION The combined application of MDCT and gastrointestinal endoscopy enhanced diagnostic accuracy for GC,provided greater consistency in preoperative staging,and improved the detection of lymph node metastasis,thereby demonstrating significant clinical utility. 展开更多
关键词 Multidetector computed tomography Gastrointestinal endoscopy Gastric cancer Preoperative staging Lymph node metastasis
暂未订购
Therapeutic effects of low-intensity transcranial focused ultrasound stimulation on ischemic stroke in rats:An in vivo evaluation using electrical impedance tomography
4
作者 Jiecheng Guo Sixuan He +4 位作者 Li Yan Lei Wang Xuetao Shi Huijing Hu Le Li 《Neural Regeneration Research》 2026年第3期1183-1190,共8页
Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance to... Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke. 展开更多
关键词 animal model brain stimulation electrical impedance tomography evaluation impedance noninvasive treatment real-time monitoring REHABILITATION STROKE transcranial focused ultrasound stimulation
暂未订购
A Novel Structure of Slot-Antenna Array for Producing Large-Area Planar Surface-Wave Plasmas 被引量:3
5
作者 陈兆权 刘明海 +3 位作者 周培勤 陈伟 蓝朝晖 胡希伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第6期655-660,共6页
The principle of surface wave plasma discharge in a rectangular cavity is introduced and the distribution of the electromagnetic field within a rectangular waveguide is analysed. A novel structure of a slot antenna ar... The principle of surface wave plasma discharge in a rectangular cavity is introduced and the distribution of the electromagnetic field within a rectangular waveguide is analysed. A novel structure of a slot antenna array is presented. In comparison with the traditional slotantenna, it is shown that the designed slot antenna array can excite effectively the surface wave coupling into the chamber, and generate a stable large-area high-density plasma. These results are useful for exploring the optimized design of the slot-antenna for surface wave plasmas. 展开更多
关键词 surface-wave plasmas slot-antenna MICROWAVE
在线阅读 下载PDF
Three-Dimensional Numerical Simulation of Surface-Wave Plasma Source 被引量:3
6
作者 蓝朝晖 陈兆权 +2 位作者 刘明海 江中和 胡希伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期66-70,共5页
A three-dimensional model of a surface-wave plasma (SWP) source is built numerically using the finite-difference time-domain (FDTD) method to investigate the structure of the surface wave propagation along the pla... A three-dimensional model of a surface-wave plasma (SWP) source is built numerically using the finite-difference time-domain (FDTD) method to investigate the structure of the surface wave propagation along the plasma-dielectric interface and the distributions of electromagnetic fields in the whole system. A good-performance excitation source technique for the waveguide which is pivotal to the simulation is presented. The technique can avoid the dc distortions of magnetic fields caused by the forcing electric wall. An example of simulation is given to confirm the existence of the surface waves. The simulation also shows that the code developed is a useful tool in the computer-aided design of the antenna of the SWP source. 展开更多
关键词 FDTD method WAVEGUIDE surface-wave plasma
在线阅读 下载PDF
Assessing the effects of model parameter assumptions on surface-wave inversion results 被引量:2
7
作者 Xuezhen Zhang Xiaodong Song 《Earthquake Science》 2024年第6期529-545,共17页
Surface-wave inversion is a powerful tool for revealing the Earth's internal structure.However,aside from shear-wave velocity(v_(S)),other parameters can influence the inversion outcomes,yet these have not been sy... Surface-wave inversion is a powerful tool for revealing the Earth's internal structure.However,aside from shear-wave velocity(v_(S)),other parameters can influence the inversion outcomes,yet these have not been systematically discussed.This study investigates the influence of various parameter assumptions on the results of surface-wave inversion,including the compressional and shear velocity ratio(v_(P)/v_(S)),shear-wave attenuation(Q_(S)),density(ρ),Moho interface,and sedimentary layer.We constructed synthetic models to generate dispersion data and compared the obtained results with different parameter assumptions with those of the true model.The results indicate that the v_(P)/v_(S) ratio,Q_(S),and density(ρ) have minimal effects on absolute velocity values and perturbation patterns in the inversion.Conversely,assumptions about the Moho interface and sedimentary layer significantly influenced absolute velocity values and perturbation patterns.Introducing an erroneous Mohointerface depth in the initial model of the inversion significantly affected the v_(S) model near that depth,while using a smooth initial model results in relatively minor deviations.The assumption on the sedimentary layer not only affects shallow structure results but also impacts the result at greater depths.Non-linear inversion methods outperform linear inversion methods,particularly for the assumptions of the Moho interface and sedimentary layer.Joint inversion with other data types,such as receiver functions or Rayleigh wave ellipticity,and using data from a broader period range or higher-mode surface waves,can mitigate these deviations.Furthermore,incorporating more accurate prior information can improve inversion results. 展开更多
关键词 shear-wave velocity model surface-wave inversion Moho interface sedimentary layer non-linear inversion
在线阅读 下载PDF
Application of passive source surface-wave method in site engineering seismic survey 被引量:2
8
作者 Chaofan Wang Jian Zhang +2 位作者 Lihui Yan Hui Liu Dong Zhao 《Earthquake Science》 2014年第1期101-106,共6页
Site engineering seismic survey provides basic data for seismic effect analysis. As an important parameter of soil, shear-wave velocity is usually obtained through wave velocity testing in borehole. In this paper, the... Site engineering seismic survey provides basic data for seismic effect analysis. As an important parameter of soil, shear-wave velocity is usually obtained through wave velocity testing in borehole. In this paper, the passive source surface-wave method is introduced into the site engineering seismic survey and practically applied in an engineering site of Shijingshan District. By recording the ubiquitous weak vibration on the earth surface, extract the dispersion curve from the surface-wave components using the SPAC method and obtain the shear-wave velocity structure from inversion. Over the depth of 42 m under- ground, it totally consists of five layers with interface depth of 3.31, 4.50, 7.23, 17.41, and 42.00 m; and shear-wave velocity of 144.0, 198.3, 339.4, 744.2, and 903.7 m/s, respectively. The inversion result is used to evaluate site classification, determine the maximum shear modulus of soil, provide basis for further seismic hazard analysis and site assessment or site zoning, etc. The result shows that the passive source surface-wave method is feasible in the site engineering seismic survey and can replace boreholes,shorten survey period, and reduce engineering cost to some extent. 展开更多
关键词 Passive source surface-wave method Shearwave velocity Dispersion curve Seismic effect Engineering seismic survey
在线阅读 下载PDF
Character Diagnosis for Surface-Wave Plasmas Excited by Surface Plasmon Polaritons 被引量:1
9
作者 陈兆权 夏广庆 +5 位作者 刘明海 胡业林 郑晓亮 李平 周启燕 胡希伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第8期754-758,共5页
The plasma parameters of planar-type surface-wave plasmas (SWPs) are diagnosed based on the resonant excitation of surface plasmon polaritons (SPPs). The plasma parameter distributions are obtained by changing the... The plasma parameters of planar-type surface-wave plasmas (SWPs) are diagnosed based on the resonant excitation of surface plasmon polaritons (SPPs). The plasma parameter distributions are obtained by changing the discharge conditions of gas pressure and incident power. The measured experimental results show that the plasma near the heating layer is excited by surface waves of SPPs while the plasma located downstream originates from diffusion Moreover, the influence of high-frequency oscillations plays a significant role in producing the proposed SWPs with bi-Maxwellian electron energy distributions. 展开更多
关键词 surface-wave plasmas plasma diagnosing surface plasmon polaritons
在线阅读 下载PDF
A deep-learning-based approach for seismic surface-wave dispersion inversion(SfNet)with application to the Chinese mainland 被引量:1
10
作者 Feiyi Wang Xiaodong Song Mengkui Li 《Earthquake Science》 2023年第2期147-168,共22页
Surface-wave tomography is an important and widely used method for imaging the crust and upper mantle velocity structure of the Earth.In this study,we proposed a deep learning(DL)method based on convolutional neural n... Surface-wave tomography is an important and widely used method for imaging the crust and upper mantle velocity structure of the Earth.In this study,we proposed a deep learning(DL)method based on convolutional neural network(CNN),named SfNet,to derive the vS model from the Rayleigh wave phase and group velocity dispersion curves.Training a network model usually requires large amount of training datasets,which is labor-intensive and expensive to acquire.Here we relied on synthetics generated automatically from various spline-based vS models instead of directly using the existing vS models of an area to build the training dataset,which enhances the generalization of the DL method.In addition,we used a random sampling strategy of the dispersion periods in the training dataset,which alleviates the problem that the real data used must be sampled strictly according to the periods of training dataset.Tests using synthetic data demonstrate that the proposed method is much faster,and the results for the vS model are more accurate and robust than those of conventional methods.We applied our method to a dataset for the Chinese mainland and obtained a new reference velocity model of the Chinese continent(ChinaVs-DL1.0),which has smaller dispersion misfits than those from the traditional method.The high accuracy and efficiency of our DL approach makes it an important method for vS model inversions from large amounts of surface-wave dispersion data. 展开更多
关键词 deep learning surface-wave inversion shear-wave velocity Chinese mainland
在线阅读 下载PDF
INTERNAL RESONANT INTERACTIONS OF THREE FREE SURFACE-WAVES IN A CIRCULAR CYLINDRICAL BASIN
11
作者 马晨明 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2003年第12期1411-1420,共10页
The basic equations of free capillary_gravity surface_waves in a circular cylindrical basin were derived from Luke's principle. Taking Galerkin's expansion of the velocity potential and the free surface elevat... The basic equations of free capillary_gravity surface_waves in a circular cylindrical basin were derived from Luke's principle. Taking Galerkin's expansion of the velocity potential and the free surface elevation, the second_order perturbation equations were derived by use of expansion of multiple scale. The nonlinear interactions with the second order internal resonance of three free surface_waves were discussed based on the above. The results include:derivation of the couple equations of resonant interactions among three waves and the conservation laws; analysis of the positions of equilibrium points in phase plane; study of the resonant parameters and the non_resonant parameters respectively in all kinds of circumstances; derivation of the stationary solutions of the second_order interaction equations corresponding to different parameters and analysis of the stability property of the solutions; discussion of the effective solutions only in the limited time range. The analysis makes it clear that the energy transformation mode among three waves differs because of the different initial conditions under nontrivial circumstance. The energy may either exchange among three waves periodically or damp or increase in single waves. 展开更多
关键词 free surface-wave internal resonant interaction stationary solution
在线阅读 下载PDF
IN VIVO VALIDATION OF DUAL-MODALITY SYSTEM FOR SIMULTANEOUS POSITRON EMISSION TOMOGRAPHY AND OPTICAL TOMOGRAPHIC IMAGING
12
作者 XIN WANG BIN ZHANG +4 位作者 XU CAO FEI LIU SHUANGQUAN LIU BAOCI SHAN JING BAI 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第2期165-171,共7页
We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast canc... We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast cancer cells which expressed redfluorescent protein(RFP).For FMT system,reflective illumination mode was adopted with full-angle data acquisition.[18F]-Fluorodeoxyglucose([18F]-FDG)was used as radioactive tracer for PET.Both data were acquired simultaneously and then reconstructed separately before fusion.Fluorescent tomography results showed exactly where the tumor was located while PET results offered more metabolic information.Results confirmed feasibility for tumor detection and showed superiority to single modality imaging. 展开更多
关键词 Dual-modality imaging positron emission tomography fluorescence molecular tomography
原文传递
Primary Study of Surface-Wave Magnitude Determined by Chinese Stations
13
作者 Ge Huancheng,Yu Meixuan,Xu Fuxi and Ni YueweiSeismological Bureau of Jiangsu Province,Nanjing 210014,China 《Earthquake Research in China》 1994年第3期124-131,共8页
Using the data set of 20±2 sec and(A/T)max of surface waves recorded by Type-763 and Type-SK seismographs from five stations in Beijing and elsewhere,the mean square deviations u and relative mean deviations D of... Using the data set of 20±2 sec and(A/T)max of surface waves recorded by Type-763 and Type-SK seismographs from five stations in Beijing and elsewhere,the mean square deviations u and relative mean deviations D of Ms values determined by five calibration functions(a,a763,a300 aN and from Msz(NEIS)are compared and analyzed.Results show that a and a763 are rather good between 20° and 160°;and a763 are rather good between 10 and 30 for 20 sec; a300 is relatively good between 160 and 179. 展开更多
关键词 surface-wave MAGNITUDE CALIBRATION FUNCTION
在线阅读 下载PDF
Role of photon-counting computed tomography in pediatric cardiovascular imaging 被引量:1
14
作者 Arosh S Perera Molligoda Arachchige Yash Verma 《World Journal of Clinical Pediatrics》 2025年第1期55-62,共8页
Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible ligh... Photon-counting computed tomography(PCCT)represents a significant advancement in pediatric cardiovascular imaging.Traditional CT systems employ energy-integrating detectors that convert X-ray photons into visible light,whereas PCCT utilizes photon-counting detectors that directly transform X-ray photons into electric signals.This direct conversion allows photon-counting detectors to sort photons into discrete energy levels,thereby enhancing image quality through superior noise reduction,improved spatial and contrast resolution,and reduced artifacts.In pediatric applications,PCCT offers substantial benefits,including lower radiation doses,which may help reduce the risk of malignancy in pediatric patients,with perhaps greater potential to benefit those with repeated exposure from a young age.Enhanced spatial resolution facilitates better visualization of small structures,vital for diagnosing congenital heart defects.Additionally,PCCT’s spectral capabilities improve tissue characterization and enable the creation of virtual monoenergetic images,which enhance soft-tissue contrast and potentially reduce contrast media doses.Initial clinical results indicate that PCCT provides superior image quality and diagnostic accuracy compared to conven-tional CT,particularly in challenging pediatric cardiovascular cases.As PCCT technology matures,further research and standardized protocols will be essential to fully integrate it into pediatric imaging practices,ensuring optimized diagnostic outcomes and patient safety. 展开更多
关键词 CARDIOVASCULAR Photon-counting detectors PEDIATRIC Photon-counting computed tomography Computed tomography
暂未订购
Progress in the application of fludeoxyglucose positron emission tomography computed tomography in biliary tract cancer 被引量:1
15
作者 Jia-Xin Yin Xin Fan +2 位作者 Qiao-Liang Chen Jing Chen Jian He 《World Journal of Hepatology》 2025年第5期32-44,共13页
Biliary tract cancer(BTC)is a group of heterogeneous sporadic diseases,including intrahepatic,hilar,and distal cholangiocarcinoma,as well as gallbladder cancer.BTC is characterized by high invasiveness and extremely p... Biliary tract cancer(BTC)is a group of heterogeneous sporadic diseases,including intrahepatic,hilar,and distal cholangiocarcinoma,as well as gallbladder cancer.BTC is characterized by high invasiveness and extremely poor prognosis,with a global increased incidence due to intrahepatic cholangiocarcinoma(ICC).The 18Ffludeoxyglucose positron emission tomography(PET)computed tomography(18F-FDG PET/CT)combines glucose metabolic information(reflecting the glycolytic activity of tumor cells)with anatomical structure to assess tumor metabolic heterogeneity,systemic metastasis,and molecular characteristics noninvasively,overcoming the limitations of traditional imaging in the detection of micrometastases and recurrent lesions.18F-FDG PET/CT offers critical insights in clinical staging,therapeutic evaluation,and prognostic prediction of BTC.This article reviews research progress in this field over the past decade,with a particular focus on the advances made in the last 3 years,which have not been adequately summarized and recognized.The research paradigm in this field is shifting from qualitative to quantitative studies,and there have been significant breakthroughs in using 18F-FDG PET/CT metabolic information to predict gene expression in ICC.Radiomics and deep learning techniques have been applied to ICC for prognostic prediction and differential diagnosis.Additionally,PET/magnetic resonance imaging is increasingly demonstrating its value in this field. 展开更多
关键词 Biliary tract cancer Positron radiopharmaceuticals Fluorodeoxyglucose positron emission tomography Radiomics Positron emission tomography computed tomography Positron emission tomography magnetic resonance imaging
暂未订购
Optical coherence tomography angiography in diabetic retinopathy:focusing on microvascular changes 被引量:4
16
作者 Yang Xiongyi Yi Guoguo +5 位作者 Chen Yanxia Yang Siyu Ai Shibei Zheng Cong Cao Mingzhe Fu Min 《国际眼科杂志》 2025年第2期179-190,共12页
AIM:To investigate the value of optical coherence tomography angiography(OCTA)indicators in the diagnosis of diabetic retinopathy(DR),and to provide patients with diabetic nephropathy(DN)with more sensitive OCTA scree... AIM:To investigate the value of optical coherence tomography angiography(OCTA)indicators in the diagnosis of diabetic retinopathy(DR),and to provide patients with diabetic nephropathy(DN)with more sensitive OCTA screening indicators to detect concurrent DR at an early stage.METHODS:A total of 200 patients who treated in the ophthalmology department of the Seventh Affiliated Hospital,Sun Yat-sen University from 2022 to 2023 were included,including 95 first-diagnosed DR patients and 105 patients without DR,and all patients underwent OCTA examination and a collection of demographics and renal function parameters.After a quality check,automated measurements of the foveal avascular zone area,vessel density(VD),and perfusion density(PD)of both 3 mm×3 mm and 6 mm×6 mm windows were obtained.RESULTS:Using random forest and multivariate Logistic regression methods,we developed a diagnostic model for DR based on 12 variables(age,FBG,SBP,DBP,HbA1c,ALT,ALP,urea/Scr,DM duration,HUA,DN,and CMT).Adding specific OCTA parameters enhanced the efficacy of the existing diagnostic model for DR(outer vessel density in 6 mm×6 mm window,AUC=0.837 vs 0.819,P=0.03).In the study of DN patients,the parameters in the 6 mm×6 mm window improved the diagnostic efficacy of DR(inner VD;outer VD;full VD;outer PD;full PD).CONCLUSION:The outer VD in the 6 mm×6 mm window can enhance the efficacy of the traditional DR diagnostic model.Meanwhile,compared with the 3 mm×3 mm window,the microvascular parameters in the 6 mm×6 mm window focusing on DN patients can be more sensitive to diagnosing the occurrence of DR. 展开更多
关键词 optical coherence tomography angiography(OCTA) diabetic retinopathy diabetic nephropathy prediction model
暂未订购
Recent progress in the applications of presynaptic dopaminergic positron emission tomography imaging in parkinsonism 被引量:1
17
作者 Yujie Yang Xinyi Li +7 位作者 Jiaying Lu Jingjie Ge Mingjia Chen Ruixin Yao Mei Tian Jian Wang Fengtao Liu Chuantao Zuo 《Neural Regeneration Research》 SCIE CAS 2025年第1期93-106,共14页
Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.... Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.This review provides a comprehensive summary of the latest developments in the application of presynaptic dopaminergic positron emission tomography imaging in disorders that manifest parkinsonism.We conducted a thorough literature search using reputable databases such as PubMed and Web of Science.Selection criteria involved identifying peer-reviewed articles published within the last 5 years,with emphasis on their relevance to clinical applications.The findings from these studies highlight that presynaptic dopaminergic positron emission tomography has demonstrated potential not only in diagnosing and differentiating various Parkinsonian conditions but also in assessing disease severity and predicting prognosis.Moreover,when employed in conjunction with other imaging modalities and advanced analytical methods,presynaptic dopaminergic positron emission tomography has been validated as a reliable in vivo biomarker.This validation extends to screening and exploring potential neuropathological mechanisms associated with dopaminergic depletion.In summary,the insights gained from interpreting these studies are crucial for enhancing the effectiveness of preclinical investigations and clinical trials,ultimately advancing toward the goals of neuroregeneration in parkinsonian disorders. 展开更多
关键词 aromatic amino acid decarboxylase brain imaging dopamine transporter Parkinson’s disease PARKINSONISM positron emission tomography presynaptic dopaminergic function vesicle monoamine transporter type 2
暂未订购
Macular microvascular and structural changes on optical coherence tomography angiography in atypical optic neuritis 被引量:1
18
作者 Chinmay Mahatme Madhurima Kaushik +2 位作者 Veerappan Rathinasabapathy Saravanan Karthik Kumar Virna M Shah 《World Journal of Methodology》 2025年第1期88-94,共7页
BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic im... BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic implications and longterm management strategies.Vascular and metabolic factors are being thought to play a role in such autoimmune neuro-inflammatory disorders,apart from the obvious immune mediated damage.With the advent of optical coherence tomography angiography(OCTA),it is easy to pick up on these subclinical macular microvascular and structural changes.AIM To study the macular microvascular and structural changes on OCTA in atypical optic neuritis.METHODS This observational cross-sectional study involved 8 NMOSD and 17 MOGAD patients,diagnosed serologically,as well as 10 healthy controls.Macular vascular density(MVD)and ganglion cell+inner plexiform layer thickness(GCIPL)were studied using OCTA.RESULTS There was a significant reduction in MVD in NMOSD and MOGAD affected as well as unaffected eyes when compared with healthy controls.NMOSD and MOGAD affected eyes had significant GCIPL thinning compared with healthy controls.NMOSD unaffected eyes did not show significant GCIPL thinning compared to healthy controls in contrast to MOGAD unaffected eyes.On comparing NMOSD with MOGAD,there was no significant difference in terms of MVD or GCIPL in the affected or unaffected eyes.CONCLUSION Although significant microvascular and structural changes are present on OCTA between atypical optic neuritis and normal patients,they could not help in differentiating between NMOSD and MOGAD cases. 展开更多
关键词 Optical coherence tomography angiography Atypical optic neuritis Macular microvascular changes Neuromyelitis optica spectrum disorders Myelin oligodendrocyte glycoprotein antibody disorder
暂未订购
Short-Term Synchronous and Asynchronous Ambient Noise Tomography in Urban Areas:Application to Karst Investigation 被引量:1
19
作者 Ya Liu Jianghai Xia +3 位作者 Bo Guan Chaoqiang Xi Ling Ning Hao Zhang 《Engineering》 2025年第5期292-308,共17页
Dense-array ambient noise tomography is a powerful tool for achieving high-resolution subsurface imag-ing,significantly impacting geohazard prevention and control.Conventional dense-array studies,how-ever,require simu... Dense-array ambient noise tomography is a powerful tool for achieving high-resolution subsurface imag-ing,significantly impacting geohazard prevention and control.Conventional dense-array studies,how-ever,require simultaneous observations of numerous stations for extensive coverage.To conduct a comprehensive karst feature investigation with limited stations,we designed a new synchronous-asyn-chronous observation system that facilitates dense array observations.We conducted two rounds of asynchronous observations,each lasting approximately 24 h,in combination with synchronous backbone stations.We achieved wide-ranging coverage of the study area utilizing 197 nodal receivers,with an average station spacing of 7 m.The beamforming results revealed distinct variations in the noise source distributions between day and night.We estimated the source strength in the stationary phase zone and used a weighting scheme for stacking the cross-correlation functions(C ^(1) functions)to suppress the influ-ence of nonuniform noise source distributions.The weights were derived from the similarity coefficients between multicomponent C^(1)functions related to Rayleigh waves.We employed the cross-correlation of C ^(1) functions(C^(2)methods)to obtain the empirical Green’s functions between asynchronous stations.To eliminate artifacts in C ^(2) functions from higher-mode surface waves in C^(1)functions,we filtered the C^(1)functions on the basis of different particle motions linked to multimode Rayleigh waves.The dispersion measurements of Rayleigh waves obtained from both the C^(1)and C^(2)functions were utilized in surface wave tomography.The inverted three-dimensional(3D)shear-wave(S-wave)velocity model reveals two significant low-velocity zones at depths ranging from 40 to 60 m,which align well with the karst caves found in the drilling data.The method of short-term synchronous-asynchronous ambient noise tomography shows promise as a cost-effective and efficient approach for urban geohazard investigations. 展开更多
关键词 Seismic interferometry Surface wave tomography Asynchronous ambient noise GEOHAZARDS Seismic ambient noise
在线阅读 下载PDF
Computed tomography-based assessment of pericoronary adipose tissue in cardiovascular diseases:Diagnostic and prognostic implications 被引量:1
20
作者 Ling-Li Wang Yuan-Bo Xiong +8 位作者 Xin-Yi Feng Ya-Yudie Liu Kai-Xiang Su Si-Yu Jiang Si-Yu Wang Ling Zhou Shao-Ke Li Dan-Dan Guo Rui Li 《World Journal of Radiology》 2025年第6期9-23,共15页
Pericoronary adipose tissue(PCAT)plays an important role in the pathogenesis and progression of cardiovascular diseases due to its bidirectional communication with the coronary artery wall.In recent years,PCAT paramet... Pericoronary adipose tissue(PCAT)plays an important role in the pathogenesis and progression of cardiovascular diseases due to its bidirectional communication with the coronary artery wall.In recent years,PCAT parameters measured using coronary computed tomography have emerged as potential noninvasive imaging biomarkers for quantifying coronary artery inflammation,with significant clinical value in the early detection,disease progression assessment,treatment efficacy evaluation,and prognosis prediction of cardiovascular diseases.Furthermore,new technologies such as PCAT radiomics analysis have broadened its potential applications in evaluating coronary plaque vulnerability,predicting cardiovascular events,and improving risk stratification.This review discusses recent advances in PCAT research,focusing on its role in coronary artery disease risk identification and inflammation monitoring,and aims to offer imaging-based insights to support its future clinical use in cardiovascular disease management. 展开更多
关键词 Pericoronary adipose tissue Radiomics Coronary computed tomography angiography Vascular inflammation Cardiovascular diseases
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部