High-voltage electrical post equipment is generally installed on steel supports,which amplifies the seismic inputs and degrades the seismic performance of equipment.This study proposed a variable cross-section damped ...High-voltage electrical post equipment is generally installed on steel supports,which amplifies the seismic inputs and degrades the seismic performance of equipment.This study proposed a variable cross-section damped steel support frame(VCDFS)with viscous dampers to reduce seismic responses of both tall and low-rise electrical equipment.The VCDFS contains a trapezoidal damper layer to generate rocking motions,enabling the diagonal viscous dampers to dissipate seismic inputs.A theoretical model of post equipment with VCDFS is established,and an optimal design procedure is proposed.The analysis shows that the remaining static stiffness ratio λ_(k) is the key parameter that determines the effectiveness of the VCDFS.The VCDFS reduces the average displacement and stress response of a post insulator by 39.4%and 44.6%,respectively,together with a significant decrease in the dynamic amplification factor.Therefore,it is recommended to use the VCDFS instead of the conventional latticed-steel frame in earthquake zones.展开更多
To evaluate the importance of the canyon topography effects on large structures, based on a rigid frame bridge across a 137-m-deep and 600-m-wide canyon, the seismic response of the canyon site is analyzed using a two...To evaluate the importance of the canyon topography effects on large structures, based on a rigid frame bridge across a 137-m-deep and 600-m-wide canyon, the seismic response of the canyon site is analyzed using a two-dimensional finite element model under different seismic SV waves with the assumptions of vertical incidence and oblique incidence to obtain the ground motions, which are used as the excitation input on the pier foundations of the bridge with improved large mass method. The results indicate that canyon topography has significant influences on the ground motions in terms of inci- dent angle. The peak ground acceleration values vary greatly from the bottom of the canyon to the upper comers. Under ver- tical incident SV waves, at the upper comers of canyon the peak ground accelerations greatly increase; whereas the peak ground accelerations diminish at the bottom comers of canyon. Under oblique incident SV waves, the shaking of the canyon slope perpendicular to the incidence direction is much more severe than that of the opposite side of canyon. And the ground surface has been characterized by larger deformations in the case of oblique incident waves. It is also concluded that the low piers and frame of the continuous rigid frame bridge ape more sensitive to the multi-support seismic excitations than the flexible high piers. The canyon topography as well as the oblique incidence of the waves brings the continuous rigid frame bridge severe responses, which should be taken into account in bridge design.展开更多
基金Guangdong Basic and Applied Basic Research Foundation under Grant Nos.2022A1515110561 and 2023A1515010072Natural Science Foundation of China under Grant Nos.52308488 and 52378499。
文摘High-voltage electrical post equipment is generally installed on steel supports,which amplifies the seismic inputs and degrades the seismic performance of equipment.This study proposed a variable cross-section damped steel support frame(VCDFS)with viscous dampers to reduce seismic responses of both tall and low-rise electrical equipment.The VCDFS contains a trapezoidal damper layer to generate rocking motions,enabling the diagonal viscous dampers to dissipate seismic inputs.A theoretical model of post equipment with VCDFS is established,and an optimal design procedure is proposed.The analysis shows that the remaining static stiffness ratio λ_(k) is the key parameter that determines the effectiveness of the VCDFS.The VCDFS reduces the average displacement and stress response of a post insulator by 39.4%and 44.6%,respectively,together with a significant decrease in the dynamic amplification factor.Therefore,it is recommended to use the VCDFS instead of the conventional latticed-steel frame in earthquake zones.
基金supported by National Natural Science Foundation of China (No. 50708100)National Science and Technology Support Project of China (No. 2006BAC13B02)partially by Basic Research Program of Institute of Mechanics Engineering, China Earthquake Administration (No. 2007B02)
文摘To evaluate the importance of the canyon topography effects on large structures, based on a rigid frame bridge across a 137-m-deep and 600-m-wide canyon, the seismic response of the canyon site is analyzed using a two-dimensional finite element model under different seismic SV waves with the assumptions of vertical incidence and oblique incidence to obtain the ground motions, which are used as the excitation input on the pier foundations of the bridge with improved large mass method. The results indicate that canyon topography has significant influences on the ground motions in terms of inci- dent angle. The peak ground acceleration values vary greatly from the bottom of the canyon to the upper comers. Under ver- tical incident SV waves, at the upper comers of canyon the peak ground accelerations greatly increase; whereas the peak ground accelerations diminish at the bottom comers of canyon. Under oblique incident SV waves, the shaking of the canyon slope perpendicular to the incidence direction is much more severe than that of the opposite side of canyon. And the ground surface has been characterized by larger deformations in the case of oblique incident waves. It is also concluded that the low piers and frame of the continuous rigid frame bridge ape more sensitive to the multi-support seismic excitations than the flexible high piers. The canyon topography as well as the oblique incidence of the waves brings the continuous rigid frame bridge severe responses, which should be taken into account in bridge design.