期刊文献+
共找到2,364篇文章
< 1 2 119 >
每页显示 20 50 100
Seismic damage characteristics and restoration strategies of the Mandalay municipal water supply system following the 2025 M 7.9 Myanmar earthquake
1
作者 Yan Peilei Guo Endong +3 位作者 Huang Yong Zhao Zhipeng A Lata Liu Jingyi 《Earthquake Engineering and Engineering Vibration》 2026年第1期13-25,共13页
Following a magnitude M 7.9 earthquake that struck near Mandalay,Myanmar in March 2025,this study investigates the seismic damage inflicted upon the city’s municipal water supply system.The analysis focuses on the fa... Following a magnitude M 7.9 earthquake that struck near Mandalay,Myanmar in March 2025,this study investigates the seismic damage inflicted upon the city’s municipal water supply system.The analysis focuses on the failure characteristics of water facilities and pipelines,examines cross-system cascading effects,and proposes corresponding recovery strategies.The main findings are as follows:(1)The damage to water plant facilities,concentrated in ancillary structures and connections due to insufficient seismic measures,demonstrated significant intensity-dependence.Increased seismic intensity not only aggravated structural damage but also compromised core treatment processes,leading to deteriorated water quality.(2)Within the same seismic intensity zone,high-density polyethylene(HDPE)pipes exhibited a significantly lower damage occurrence rate than ductile iron(DI)pipes,highlighting the material’s substantial influence on seismic performance.Moreover,a strong positive correlation was observed between the overall pipeline network damage and the seismic intensity.The average damage rate in IntensityⅨzones was 6.84 times that of IntensityⅧzones.(3)A cascading failure,initiated by a power outage,led to water supply disruption,loss of emergency response capability,and elevated secondary risks.This strongly coupled cross-system effect resulted in significant spatiotemporal propagation of disaster impacts.(4)The post-earthquake recovery adopted a phased strategy that prioritized critical facilities.Actions involved rapidly restoring the core supply zone with temporary points,reinstating the water plant’s power supply,and deploying targeted technologies for efficient pipeline repair.The outcomes of this study are expected to provide critical support and a valuable reference for developing earthquake-resilient urban water supply systems. 展开更多
关键词 M 7.9 Myanmar earthquake water supply system seismic damage characteristics cross-system cascading failure restoration strategies
在线阅读 下载PDF
Data-driven measurement performance evaluation of voltage transformers in electric railway traction power supply systems
2
作者 Zhaoyang Li Muqi Sun +5 位作者 Jun Zhu Haoyu Luo Qi Wang Haitao Hu Zhengyou He Ke Wang 《Railway Engineering Science》 2025年第2期311-323,共13页
Critical for metering and protection in electric railway traction power supply systems(TPSSs),the measurement performance of voltage transformers(VTs)must be timely and reliably monitored.This paper outlines a three-s... Critical for metering and protection in electric railway traction power supply systems(TPSSs),the measurement performance of voltage transformers(VTs)must be timely and reliably monitored.This paper outlines a three-step,RMS data only method for evaluating VTs in TPSSs.First,a kernel principal component analysis approach is used to diagnose the VT exhibiting significant measurement deviations over time,mitigating the influence of stochastic fluctuations in traction loads.Second,a back propagation neural network is employed to continuously estimate the measurement deviations of the targeted VT.Third,a trend analysis method is developed to assess the evolution of the measurement performance of VTs.Case studies conducted on field data from an operational TPSS demonstrate the effectiveness of the proposed method in detecting VTs with measurement deviations exceeding 1%relative to their original accuracy levels.Additionally,the method accurately tracks deviation trends,enabling the identification of potential early-stage faults in VTs and helping prevent significant economic losses in TPSS operations. 展开更多
关键词 Voltage transformer Traction power supply system Measurement performance Data-driven evaluation Abrupt change detection Bootstrap confidence interval
在线阅读 下载PDF
REDUNDANCY TECHNOLOGY FOR AIRCRAFT MULTI-CHANNEL DC POWER SUPPLY SYSTEM 被引量:2
3
作者 杨善水 魏秦华 +2 位作者 黄仙密 居蓉蓉 王莉 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2007年第4期305-309,共5页
The redundancy technology for the aircraft multi-channel DC electrical power supply system is studied. In this system, the key loads can obtain power from seven sources. The direct current bus power control unit (DC ... The redundancy technology for the aircraft multi-channel DC electrical power supply system is studied. In this system, the key loads can obtain power from seven sources. The direct current bus power control unit (DC BPCU) is put forward to manage the power supply system automatically. The redundancy innovation is also applied in both hardware and software of DC BPCU. Furthermore, redundancy fault diagnosis is discussed through the existing parts. Experiments and applications show that the proposed aircraft DC power supply system possesses many advantages of high reliability, high automation and so on. 展开更多
关键词 redundant power supply bus power control unit(BPCU) redundancy hardware redundancy software
在线阅读 下载PDF
Optimal operation of water supply systems with tanks based on genetic algorithm 被引量:6
4
作者 俞亭超 张土乔 李洵 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期886-893,共8页
In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow ... In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow and water source head. By using pump-station pressure head and initial tank water levels as decision variables, the model of optimal allocation of water supply between pump-sources was developed. Genetic algorithm was introduced to deal with the model of optimal allocation of water supply. Methods for handling each constraint condition were put forward, and overcome the shortcoming such as premature convergence of genetic algorithm; a solving method was brought forward in which genetic algorithm was combined with simulated annealing technology and self-adaptive crossover and mutation probabilities were adopted. An application example showed the feasibility of this algorithm. 展开更多
关键词 Water supply system Optimal operation Genetic algorithm TANK
在线阅读 下载PDF
An aviation oxygen supply system based on a mechanical ventilation model 被引量:5
5
作者 Yan SHI Yixuan WANG +2 位作者 Maolin CAI Bolun ZHANG Jian ZHU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2018年第1期197-204,共8页
At high altitudes, an Aviation Oxygen Supply System (AOSS) protects pilots from low pressure and hypoxia by continuously providing oxygen corresponding to the pilots' dynamic respiratory properties. An AOSS mainly ... At high altitudes, an Aviation Oxygen Supply System (AOSS) protects pilots from low pressure and hypoxia by continuously providing oxygen corresponding to the pilots' dynamic respiratory properties. An AOSS mainly consists of oxygen supercharging machines which are used in a high-altitude flight cabin to supply pressurized oxygen to pilots. Therefore, it is of great significance to study the airflow dynamic characteristics of an AOSS for safe, continuous, and efficient oxygen supply. In this paper, an AOSS is firstly simplified and considered as a mechanical ventilation system. Then, its corresponding mathematical model is constructed. Next, to verify the mathematical model, a prototype AOSS with a lung simulator is proposed for an experimental study. Afterwards, to build a foundation for the optimization of the AOSS, the airflow dynamic characteristics of an aircraft are analyzed, and the effects of key parameters on the respiration system are researched. Through experimental and simulation studies, it can be concluded that the mathematical model is effective. Subsequently, for stability during the respiration process, we consider setting the equivalent throttling areas of the inspiration and expiration pipelines smaller within certain limits; additionally, an excessively high oxygen supply pressure will disturb smooth airflow, and in a low-pressure environment, the pressure can be 84 cmH20 lower than the standard atmospheric pressure. This research can be referred to in the design of an oxygen supply system and the study on optimization of airflow dynamic characteristics. 展开更多
关键词 AVIATION Dynamic characteristics Mathematical modeling Mechanical ventilation Oxygen supply system
原文传递
Evaluation and optimization of secondary water supply system renovation 被引量:5
6
作者 TIAN Yi-mei SI Yan-jie +1 位作者 LI Hong WU Mi-fang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第9期1488-1494,共7页
Due to pollution in second water supply system (SWSS),nine renovation alternative plans were proposed and com-prehensive evaluations of different plan based on Analytical Hierarchy Process (AHP) were presented in this... Due to pollution in second water supply system (SWSS),nine renovation alternative plans were proposed and com-prehensive evaluations of different plan based on Analytical Hierarchy Process (AHP) were presented in this paper. Comparisons of advantages and disadvantages among the plans of SWSS renovations provided solid foundation for selecting the most appro-priate plan for engineering projects. In addition,a mathematical model of the optimal combination of renovation plans has been set up and software Lingo was used to solve the model. As a case study,the paper analyzed 15 buildings in Tianjin City. After simulation of the SWSS renovation system,an optimal scheme was obtained,the result of which indicates that 10 out of those 15 buildings need be renovated in priority. The renovation plans selected for each building are the ones ranked higher in the com-prehensive analysis. The analysis revealed that the optimal scheme,compared with two other randomly calculated ones,increased the percentage of service population by 19.6% and 13.6% respectively,which significantly improved social and economical benefits. 展开更多
关键词 Secondary water supply system (SWSS) Renovation plan Analytical Hierarchy Process (AHP) Hierarchical model OPTIMIZATION
在线阅读 下载PDF
A survey on heavy metal concentrations in residential neighborhoods: The influence of secondary water supply systems 被引量:2
7
作者 Dong Hu Jie Zeng +4 位作者 Yue Hu Xiali Fei Xinyan Xiao Mingbao Feng Xin Yu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2022年第7期37-45,共9页
Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to i... Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to investigate the influence of SWSSs on the seasonal changes in heavy metal concentrations from input water to tank and tap water. The concentrations of nine evaluated heavy metals in all groups of water samples were found to be far below the specified standard levels in China. The concentrations of Fe, Mn, and Zn increased significantly from the input water samples to the tank and tap water samples in spring and summer( p < 0.05), especially for the water samples that had been stagnant for a long time. Negative correlations were found between most of the heavy metals and residual chlorine(Fe, Cu, Zn, and As, r =-0.186 to-0.519, p < 0.05). In particular, a high negative correlation was observed between Fe and residual chlorine( r =-0.489 to-0.519, p < 0.01) in spring and summer. Fe and Mn displayed positive correlations with turbidity( r = 0.672 and 0.328, respectively;p < 0.05). In addition, Cr and As were found to be positively associated with some nutrients(NO, TN, and SO;r = 0.420-0.786, p < 0.01). The material of the storage tanks had little influence on the difference in heavy metal concentrations. Overall, this survey illustrated that SWSSs may pose a chronic threat to water quality and could provide useful information for practitioners. 展开更多
关键词 Residential neighborhoods Secondary water supply systems Tank materials Water stagnation Residual chlorine Heavy metals
原文传递
Optimal Dispatching of Large-scale Water Supply System 被引量:3
8
作者 吕谋 SONG Shuang +1 位作者 Zhao Hongbin ZHANG Tuqiao 《High Technology Letters》 EI CAS 2003年第2期21-26,共6页
This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model... This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model, which may be solved by utilizing the hierarchical optimization method, is established. In special, based on the analyses of the water supply system containing variable-speed pumps, a software tool has been developed successfully. The application of this model to the city of Shenyang (China) is compared to experiential strategy. The results of this study show that the developed model is a very promising optimization method to control the large-scale water supply systems. 展开更多
关键词 optimal dispatching water supply system water networks implicit model hierarchical optimization
在线阅读 下载PDF
A preventive opportunistic maintenance method for railway traction power supply system based on equipment reliability 被引量:5
9
作者 Sheng Lin Nan Li +4 位作者 Ding Feng Xiaomin Guo Weiguo Pan Jun Wang Chao Yang 《Railway Engineering Science》 2020年第2期199-211,共13页
Conventional maintenance mode for the traction power supply system(TPSS)is to perform scheduled regular maintenance activities for power supply equipment,while such maintenance mode may result in undue maintenance tas... Conventional maintenance mode for the traction power supply system(TPSS)is to perform scheduled regular maintenance activities for power supply equipment,while such maintenance mode may result in undue maintenance tasks and low efficiency due to different degradation processes of different sorts of equipment.To address this problem,this paper introduces a preventive opportunistic maintenance(POM)method for TPSS based on equipment reliability.Firstly,a POM model is established by considering the equipment reliability degradation process based on Weibull distribution.Then,by considering the total power outage time in the planned operation cycle of TPSS as the optimization objective,the optimal maintenance scheme of TPSS is formulated by iterative method of maintenance strategies.The proposed method is verified by introducing practical maintenance strategies and fault record data of the traction transformer,circuit breaker and disconnector in an actual TPSS of a railway administration.Results show that the presented method can make full use of the existing fault data to develop a POM scheme for TPSS.It can improve maintenance efficiency and reduce power outage time,providing guidance to formulate scientific maintenance strategies for TPSS. 展开更多
关键词 Electrified railway Opportunistic maintenance interval Preventive opportunistic maintenance RELIABILITY Traction power supply system Weibull distribution
在线阅读 下载PDF
Method of Distinguishing Hydrologic Drought for Water Supply System 被引量:2
10
作者 冯平 韩松 李绍飞 《Transactions of Tianjin University》 EI CAS 2005年第5期371-375,共5页
It is very common to design water supply system to adjust runoff. Thus it will not meet the practical needs if only the hydrologic drought in natural basin is studied. In practice the natural water balance and water d... It is very common to design water supply system to adjust runoff. Thus it will not meet the practical needs if only the hydrologic drought in natural basin is studied. In practice the natural water balance and water deficits must be researched, i. e. . the adjusting effects of the water supply sys- tem such as a reservoir should be considered, and the drought event be distinguished according to the special system. The problem of drought identification under adjusted runoff was investigated in this study. By considering water transfer during different periods, a method to distinguish hydrologic drought for the water supply system was developed, and a standard drought severity index SWDSI was proposed. The method has been applied in Pan Jiakou water supply system in China. From 1953 to 1997,a total of 14 hydrologic droughts were identified in the water supply system, among which there were 3 severe droughts, 6 moderate droughts and 5 light droughts. The results are in good agreement with the historic drought records. 展开更多
关键词 DROUGHT water supply system - SWDSI drought identification RUNOFF
在线阅读 下载PDF
Reliability Analysis of Hydraulic Transmission Oil Supply System of Power-Shift Steering Transmission with GO Methodology 被引量:3
11
作者 伊枭剑 董海平 +2 位作者 姜基平 赖岳华 张忠 《Journal of Donghua University(English Edition)》 EI CAS 2014年第6期785-788,共4页
GO methodology is a success-oriented method for system reliability analysis. There are components with multi-fault modes in repairable systems. It is a problem to use the existing GO method to make reliability analysi... GO methodology is a success-oriented method for system reliability analysis. There are components with multi-fault modes in repairable systems. It is a problem to use the existing GO method to make reliability analysis of such repairable systems. A new GO method for reliability analysis of such repairable systems with multifault modes was presented. Firstly, calculation equations of reliability parameters of operators which were used to describe components with multi-fault modes in reparable systems were derived based on Markov process theory. Then, this new GO method was applied in reliability analysis of a hydraulic transmission oil supply system( HTOSS) of a power-shift steering transmission at low and high speeds. Finally,Compared with fault tree analysis( FTA) and Monte Carlo simulation,the results show that this new GO method is correct and suitable for reliability analysis of repairable system with multi-fault modes. 展开更多
关键词 multi-fault modes GO methodology reliability analysis hydraulic transmission oil supply system(HTOSS) of power-shift steering transmission
在线阅读 下载PDF
Influence of soil resistivity on stray current in power supply system of urban rail transit 被引量:2
12
作者 CHEN Wanglong LI Yaning WANG Ye 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第3期261-266,共6页
In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit,we establish an equivalent circuit model of the rail-to-ground structure based on resistance network ... In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit,we establish an equivalent circuit model of the rail-to-ground structure based on resistance network method first.After measuring the soil resistivity of a real subway system,a simulation model is established in Matlab to obtain the stray currents at different soil resistivities.Then the influence of soil resistivity on stray current is analyzed.Afterwards,to verify the rationality and reliability of the simulation model,we design a test circuit to measure the stray current and rail-to-ground voltage in a real subway system,and a comparison of the experimentally measured results and simulation results is presented.The results show that the stray current is the maximum when the soil resistivity is 211.57Ω·m;when the soil resistivity is 768.47Ω·m,the stray current is the minimum,that is,the smaller the soil resistivity,the greater the stray current.Therefore,the resistivity should be increased as much as possible when ramming the track foundation in urban rail transit system. 展开更多
关键词 urban rail transit power supply system stray current soil resistivity four-electrode method
在线阅读 下载PDF
Distributed Order-Up-To Inventory Control in Networked Supply Systems With Delay 被引量:1
13
作者 Przemysław Ignaciuk 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2021年第10期1709-1714,共6页
In this work, the dynamics of networked goods distribution systems subject to the control of a continuous-review order-up-to inventory policy are investigated. In the analytical study, as opposed to the earlier models... In this work, the dynamics of networked goods distribution systems subject to the control of a continuous-review order-up-to inventory policy are investigated. In the analytical study, as opposed to the earlier models constrained to the serial and arborescent interconnection structures, an arbitrary multiechelon topology is considered. This external, uncertain demand,following any distribution, may be imposed on all network nodes,not just conveniently selected contact points. As in the physical systems, stock relocation to refill the reserves is subject to nonnegligible delay, which poses a severe stability threat and may lead to cost-inefficient decisions. A state-space model is created and used as the framework for analyzing system properties. In particular, it is formally demonstrated that despite unpredictable demand fluctuations, a feasible(nonnegative and bounded)reserves replenishment signal is generated at all times, and the stock gathered at the nodes does not surpass a finite, precisely determined level. The theoretical content is illustrated with a case study of the Chinese oil supply system. 展开更多
关键词 Inventory control NETWORKS supply systems time-delay systems
在线阅读 下载PDF
Optimal dispatch approach for rural multi-energy supply systems considering virtual energy storage 被引量:1
14
作者 Yanze Xu Yunfei Mu +3 位作者 Haijie Qi Hairun Li Peng Yu Shumin Sun 《Global Energy Interconnection》 EI CSCD 2023年第6期675-688,共14页
In response to the underutilization of energy and insufficient flexible operation capability of rural energy supply systems in China,this study proposes an optimal dispatch approach for a rural multi-energy supply sys... In response to the underutilization of energy and insufficient flexible operation capability of rural energy supply systems in China,this study proposes an optimal dispatch approach for a rural multi-energy supply system(RMESS)considering virtual energy storage(VES).First,to enable the flexible utilization of rural biomass resources and the thermal inertia of residential building envelopes,this study constructed VES-I and VES-II models that describe electrical-thermal and electrical-gas coupling from an electrical viewpoint.Subsequently,an RMESS model encompassing these two types of VES was formulated.This model delineates the intricate interplay of multi-energy components within the RMESS framework and facilitates the precise assessment of the adjustable potential for optimizing RMESS operations.Based on the above models,a day-ahead optimal dispatch model for an RMESS considering a VES is proposed to achieve optimal economic performance while ensuring efficient energy allocation.Comparative simulations validated the effectiveness of the VES modeling and the day-ahead optimal dispatch approach for the RMESS. 展开更多
关键词 Virtual energy storage Rural multi-energy supply system Multi-energy coupling Optimal dispatch
在线阅读 下载PDF
Reactive Power Compensation and Harmonic Suppression for Power Supply System of HT-7U Superconductive Tokamak 被引量:1
15
作者 陶骏 刘正之 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第1期629-635,共7页
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design... In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load. 展开更多
关键词 In Reactive Power Compensation and Harmonic Suppression for Power supply system of HT-7U Superconductive Tokamak APF HT
在线阅读 下载PDF
Draft sensation distribution of air jet supply system in large space building in summer
16
作者 蔡宁 黄晨 曹伟武 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期246-248,共3页
To study the draft sensation distribution of an air jet supply system in a large space building in summer,experiments are conducted in a large laboratory.The temperature,velocity and draft sensation distributions at a... To study the draft sensation distribution of an air jet supply system in a large space building in summer,experiments are conducted in a large laboratory.The temperature,velocity and draft sensation distributions at a nozzle height of 4 m in the occupied zone are obtained.Then,the numerical simulation under the test condition is carried out by the computational fluid dynamics(CFD)method.The calculation results of the indoor vertical temperature and the draft sensation distribution are validated by the test data.Simulations with different nozzle heights are conducted.The satisfactory air supply condition is determined by analyzing the draft sensations and the temperatures in the occupied zone under three conditions.The simulation results show that the optimal draft sensation distribution and the uniform temperature and velocity fields can be obtained at a nozzle height of 5 m. 展开更多
关键词 computational fluid dynamics draft sensation air jet supply thermal comfort
在线阅读 下载PDF
Nitrogen Gas Heating and Supply System for SST-1 Tokamak
17
作者 Ziauddin KHAN Firozkhan PATHAN +7 位作者 Yuvakiran PARAVASTU Siju GEORGE Gattu RAMESH Hima BINDU Dilip C. RAVAL Prashant THANKEY KalpeshDHANANI Subrata PRADHAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期157-160,共4页
Steady State Tokamak (SST-1) vacuum vessel baking as well as baking of the first wall components of SST-1 are essential to plasma physics experiments. Under a refurbishment spectrum of SST-1, the nitrogen gas heatin... Steady State Tokamak (SST-1) vacuum vessel baking as well as baking of the first wall components of SST-1 are essential to plasma physics experiments. Under a refurbishment spectrum of SST-1, the nitrogen gas heating and supply system has been fully refurbished. The SST-1 vacuum vessel consists of ultra-high vacuum (UHV) compatible eight modules and eight sectors. Rectangular baking channels are embedded on each of them. Similarly, the SST-1 plasma facing components (PFC) are comprised of modular graphite diverters and movable graphite based limiters. The nitrogen gas heating and supply system would bake the plasma facing components at 350 ~C and the SST-1 vacuum vessel at 150 ~C over an extended duration so as to remove water vapour and other absorbed gases. An efficient PLC based baking facility has been developed and implemented for monitoring and control purposes. This paper presents functional and operational aspects of a SST-1 nitrogen gas heating and supply system. Some of the experimental results obtained during the baking of SST-1 vacuum modules and sectors are also presented here. 展开更多
关键词 SST-1 heating and supply system graphite based limiters PFC
在线阅读 下载PDF
Research on the longitudinal protection of a through-type cophase traction direct power supply system based on the empirical wavelet transform
18
作者 Lu Li Zeduan Zhang +5 位作者 Wang Cai Qikang Zhuang Guihong Bi Jian Deng Shilong Chen Xiaorui Kan 《Global Energy Interconnection》 EI CSCD 2024年第2期206-216,共11页
This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a disti... This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances. 展开更多
关键词 Through-type Cophase traction direct power supply system Traction network Empirical wavelet transform(EWT) Longitudinal protection
在线阅读 下载PDF
Design and Analysis of a Small Sewage Source Heat Pump Triple Supply System
19
作者 Chunxue Gao Yu Hao Qiuxin Liu 《Energy Engineering》 EI 2021年第3期667-678,共12页
Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditio... Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%. 展开更多
关键词 Triple supply system of small sewage source heat pump SIMULATION system optimization energy saving and environmental protection
在线阅读 下载PDF
A Study of High-Power Thyristor Switch of Poloidal-Field Power Supply System in HT-7U Super-Conductive Tokamak
20
作者 温家良 刘正之 +1 位作者 付鹏 许家治 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第5期1005-1010,共6页
Through theoretical analysis of thyristor switch, criterion of turn-off was derived for the design of thyristor switch. The expression of parameter design and its math model during the turn-off were deduced. The simul... Through theoretical analysis of thyristor switch, criterion of turn-off was derived for the design of thyristor switch. The expression of parameter design and its math model during the turn-off were deduced. The simulation and experiment have been accomplished to validate the analysis. 展开更多
关键词 A Study of High-Power Thyristor Switch of Poloidal-Field Power supply system in HT-7U Super-Conductive Tokamak HT
在线阅读 下载PDF
上一页 1 2 119 下一页 到第
使用帮助 返回顶部