期刊文献+
共找到306篇文章
< 1 2 16 >
每页显示 20 50 100
Adaptive subtraction with 3D U-net and 3D data windows to suppress seismic multiples
1
作者 Jin-Qiang Huang Li-Yun Fu +3 位作者 Jia-Hui Ma Xing-Zhong Du Zhong-Xiao Li Ke-Yi Sun 《Petroleum Science》 2025年第3期1125-1139,共15页
The deep convolutional neural network U-net has been introduced into adaptive subtraction, which is a critical step in effectively suppressing seismic multiples. The U-net approach has higher precision than the tradit... The deep convolutional neural network U-net has been introduced into adaptive subtraction, which is a critical step in effectively suppressing seismic multiples. The U-net approach has higher precision than the traditional linear regression approach. However, the existing 2D U-net approach with 2D data windows can not deal with elaborate discrepancies between the actual and simulated multiples along the gather direction. It may lead to erroneous preservation of primaries or generate obvious vestigial multiples, especially in complex media. To further enhance the multiple suppression accuracy, we present an adaptive subtraction approach utilizing 3D U-net architecture, which can adaptively separate primaries and multiples utilizing 3D windows. The utilization of 3D windows allows for enhanced depiction of spatial continuity and anisotropy of seismic events along the gather direction in comparison to 2D windows. The 3D U-net approach with 3D windows can more effectively preserve the continuity of primaries and manage the complex disparities between the actual and simulated multiples. The proposed 3D U-net approach exhibits 1 dB improvement in the signal-to-noise ratio compared to the 2D U-net approach, as observed in the synthesis data section, and exhibits more outstanding performance in the preservation of primaries and removal of residual multiples in both synthesis and reality data sections. Moreover, to expedite network training in our proposed 3D U-net approach we employ the transfer learning (TL) strategy by utilizing the network parameters of 3D U-net estimated in the preceding data segment as the initial network parameters of 3D U-net for the subsequent data segment. In the reality data section, the 3D U-net approach incorporating TL reduces the computational expense by 70% compared to the one without TL. 展开更多
关键词 Adaptive subtraction 3D U-net 3D data windows Transfer learning Multiple suppression
原文传递
Subtraction of liposome signals in cryo-EM structural determination of protein-liposome complexes
2
作者 李首卿 李明 +1 位作者 王玉梅 李雪明 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期569-577,共9页
Reconstituting membrane proteins in liposomes and determining their structure is a common method for determining membrane protein structures using single-particle cryo-electron microscopy(cryo-EM).However,the strong s... Reconstituting membrane proteins in liposomes and determining their structure is a common method for determining membrane protein structures using single-particle cryo-electron microscopy(cryo-EM).However,the strong signal of liposomes under cryo-EM imaging conditions often interferes with the structural determination of the embedded membrane proteins.Here,we propose a liposome signal subtraction method based on single-particle two-dimensional(2D)classification average images,aimed at enhancing the reconstruction resolution of membrane proteins.We analyzed the signal distribution characteristics of liposomes and proteins within the 2D classification average images of protein–liposome complexes in the frequency domain.Based on this analysis,we designed a method to subtract the liposome signals from the original particle images.After the subtraction,the accuracy of single-particle three-dimensional(3D)alignment was improved,enhancing the resolution of the final 3D reconstruction.We demonstrated this method using a PIEZO1-proteoliposome dataset by improving the resolution of the PIEZO1 protein. 展开更多
关键词 CRYO-EM protein–liposome complexes liposome signal subtraction 2D classification averaging
原文传递
Left atrial appendage occluder detachment treated with transthoracic ultrasound combined with digital subtraction angiography guided catcher:A case report
3
作者 Kai Yu Yun-Hua Mei 《World Journal of Clinical Cases》 SCIE 2024年第6期1157-1162,共6页
BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innova... BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular. 展开更多
关键词 Left atrial appendage occluder DETACHMENT Ultrasound combined with digital subtraction angiography Interventional operation Successfully captured Case report
暂未订购
Enhancing transjugular intrahepatic portosystemic shunt procedure efficiency with digital subtraction angiography image overlay technology in esophagogastric variceal bleeding
4
作者 Xiao-Yan Li Yao Li +3 位作者 Wen-Qiang Li Shuai Ju Zhi-Hui Dong Jian-Jun Luo 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第9期2870-2877,共8页
BACKGROUND Transjugular intrahepatic portosystemic shunt(TIPS)is a pivotal intervention for managing esophagogastric variceal bleeding in patients with chronic hepatic schistosomiasis.AIM To evaluate the efficacy of d... BACKGROUND Transjugular intrahepatic portosystemic shunt(TIPS)is a pivotal intervention for managing esophagogastric variceal bleeding in patients with chronic hepatic schistosomiasis.AIM To evaluate the efficacy of digital subtraction angiography image overlay tech-nology(DIT)in guiding the TIPS procedure.METHODS We conducted a retrospective analysis of patients who underwent TIPS at our hospital,comparing outcomes between an ultrasound-guided group and a DIT-guided group.Our analysis focused on the duration of the portosystemic shunt puncture,the number of punctures needed,the total surgical time,and various clinical indicators related to the surgery.RESULTS The study included 52 patients with esophagogastric varices due to chronic hepatic schistosomiasis.Results demonstrated that the DIT-guided group expe-rienced significantly shorter puncture times(P<0.001)and surgical durations(P=0.022)compared to the ultrasound-guided group.Additionally,postoperative assessments showed significant reductions in aspartate aminotransferase,B-type natriuretic peptide,and portal vein pressure in both groups.Notably,the DIT-guided group also showed significant reductions in total bilirubin(P=0.001)and alanine aminotransferase(P=0.023).CONCLUSION The use of DIT for guiding TIPS procedures highlights its potential to enhance procedural efficiency and reduce surgical times in the treatment of esophagogastric variceal bleeding in patients with chronic hepatic schistoso-miasis. 展开更多
关键词 Portal hypertension Digital subtraction angiography Image overlay technology Hepatic artery labeling Transjugular intrahepatic portosystemic shunt
暂未订购
How Prime Numbers Are Interconnected and Built with Two Equations: Addition and Subtraction Rules the Function (6µ)
5
作者 John Richard Wisdom 《Advances in Pure Mathematics》 2024年第4期228-241,共14页
Are all prime numbers linked by four simple functions? Can we predict when a prime will appear in a sequence of primes? If we classify primes into two groups, Group 1 for all primes that appear before ζ (such that , ... Are all prime numbers linked by four simple functions? Can we predict when a prime will appear in a sequence of primes? If we classify primes into two groups, Group 1 for all primes that appear before ζ (such that , for instance 5, ), an even number divisible by 3 and 2, and Group 2 for all primes that are after ζ (such that , for instance 7), then we find a simple function: for each prime in each group, , where n is any natural number. If we start a sequence of primes with 5 for Group 1 and 7 for Group 2, we can attribute a μ value for each prime. The μ value can be attributed to every prime greater than 7. Thus for Group 1, and . Using this formula, all the primes appear for , where μ is any natural number. 展开更多
关键词 Number Theory Prime Number Groups Twin Primes Prime Structure and Sequence Prime subtraction and Addition
在线阅读 下载PDF
Semi-partial Quadratic Subtraction Set Pair Potential(SQSSPP)method for regional drought risk assessment:A case study in Suzhou City,China
6
作者 Datang Jin Qibing Zhang +3 位作者 Guoqing Wang Xiaosan Shang Yong Hu Ting Zhou 《River》 2024年第3期304-315,共12页
Drought risk assessment plays a crucial role in effective drought management.However,it is often challenging due to the intricate relationships among various indicators and the lack of practical guidance.This study pr... Drought risk assessment plays a crucial role in effective drought management.However,it is often challenging due to the intricate relationships among various indicators and the lack of practical guidance.This study presents a drought risk assessment model developed using the Semi-partial Quadratic Subtraction Set Pair Potential(SQSSPP)method,which is derived from the theory of set pair analysis.The indicator system comprises 21 indicators divided into four subsystems.The SQSSPP method utilizes uncertainty information in the overall development trend of regional drought risk states by extracting connection numbers from the Sub-traction Set Pair Potential(SSPP),improving the reliability of evaluation results.The SQSSPP method is validated through a case study of Suzhou City,China,from 2007 to 2017.Three grades are used to evaluate comprehensive drought risk.The result shows an overall decreasing trend over time,with a level III risk in 2010 and consistently at level II from 2011 to 2017.Indicators in the hazard and resilience subsystems are the primary factors influencing drought risk in the Suzhou City.Specific indicators requiring emphasis for improvement are identified,including arable land rate,agricultural population ratio,reservoir regulation rate,current water supply capacity,and irrigation index.The SQSSPP method not only provides targeted drought risk assessment but also provides valuable guidance for future water resource management.While the study focuses on Suzhou City,the proposed approach is applicable to broader-scale risk management evaluations and practices. 展开更多
关键词 connection number drought risk assessment Semipartial Quadratic subtraction Set Pair Potential(SQSSPP) set pair analysis Suzhou City
在线阅读 下载PDF
Detection of hypervascular hepatocellular carcinoma: Comparison of multi-detector CT with digital subtraction angiography and Lipiodol CT 被引量:16
7
作者 Xiao-HuaZheng Yong-SongGuan Xiang-PingZhou JuanHuang LongSun XiaoLi YuanLiu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第2期200-203,共4页
AIM: The purpose of this study was to compare the diagnostic accuracy of biphasic multi-detector row helical computed tomography (MDCT), digital subtraction angiography (DSA)and Lipiodol computed tomography (CT) in de... AIM: The purpose of this study was to compare the diagnostic accuracy of biphasic multi-detector row helical computed tomography (MDCT), digital subtraction angiography (DSA)and Lipiodol computed tomography (CT) in detection of hypervascular hepatocellular carcinoma (HCC).METHODS: Twenty-eight patients with nodular HCC underwent biphasic MDCT examination: hepatic arterial phase (HAP) 25 s and portal venous phase (PVP) 70 s after injection of the contrast medium (1.5 mL/kg). They also underwent hepatic angiography and intra-arterial infusion of iodized oil. Lipiodol CT was performed 3-4 wk after infusion. MDCT images were compared with DSA and Lipiodol CT images for detection of hepatic nodules.RESULTS: The three imaging techniques had the same sensitivity in detecting nodules >20 mm in diameter. There was no significant difference in the sensitivity among HAP-MDCT, Lipiodol CT and DSA for nodules of 10-20 mm in diameter. For the nodules <10 mm in diameter, HAP-MDCT identified 47, Lipiodol CT detected 27 (X2= 11.3, P= 0.005<0.01, HAP-MDCT vs Lipiodol CT) and DSA detected 16(X2= 9.09, P= 0.005<0.01 vs Lipiodol CT and X2= 29.03,P = 0.005<0.01 vs HAP-MDCT). However, six nodules <10 mm in diameter were detected only by Lipiodol CT.CONCLUSION: MDCT and Lipiodol CT are two complementary modalities. At present, MDCT does not obviate the need for DSA and subsequent Lipiodol CT as a preoperative examination for HCC. 展开更多
关键词 Hypervascular hepatocellular carcinoma Multi-detector CT Digital subtraction angiography Lipiodol CT
暂未订购
Adaptive multiple subtraction using a constrained L1-norm method with lateral continuity 被引量:10
8
作者 Pang Tinghua Lu Wenkai Ma Yongjun 《Applied Geophysics》 SCIE CSCD 2009年第3期241-247,299,300,共9页
The Lt-norm method is one of the widely used matching filters for adaptive multiple subtraction. When the primaries and multiples are mixed together, the L1-norm method might damage the primaries, leading to poor late... The Lt-norm method is one of the widely used matching filters for adaptive multiple subtraction. When the primaries and multiples are mixed together, the L1-norm method might damage the primaries, leading to poor lateral continuity. In this paper, we propose a constrained L1-norm method for adaptive multiple subtraction by introducing the lateral continuity constraint for the estimated primaries. We measure the lateral continuity using prediction-error filters (PEF). We illustrate our method with the synthetic Pluto dataset. The results show that the constrained L1-norm method can simultaneously attenuate the multiples and preserve the primaries. 展开更多
关键词 Multiple attenuation adaptive multiple subtraction L1-norm lateral continuity
在线阅读 下载PDF
Interventional digital subtraction angiography for small bowel gastrointestinal stromal tumors with bleeding 被引量:7
9
作者 Yao-Ting Chen Hong-Liang Sun +5 位作者 Jiang-Hong Luo Jia-Yan Ni Dong Chen Xiong-Ying Jiang Jing-Xing Zhou Lin-Feng Xu 《World Journal of Gastroenterology》 SCIE CAS 2014年第47期17955-17961,共7页
AIM: To retrospectively evaluate the diagnostic efficacy of interventional digital subtraction angiography (DSA) for bleeding small bowel gastrointestinal stromal tumors (GISTs).
关键词 Gastrointestinal stromal tumors Small bowel Digital subtraction angiography INTERVENTIONAL EMBOLIZATION BLEEDING
暂未订购
Digital subtraction angiography for the analysis of supraaortic vessels: What is its role nowadays? 被引量:7
10
作者 Luca Saba 《World Journal of Radiology》 CAS 2011年第6期147-151,共5页
For about 50 years, angiography represented the only imaging method for studying carotid arteries in order to detect the presence of pathological stenosis due to atherosclerotic plaque. Recently, thanks to the use of ... For about 50 years, angiography represented the only imaging method for studying carotid arteries in order to detect the presence of pathological stenosis due to atherosclerotic plaque. Recently, thanks to the use of non-invasive methods, physicians are able to study and quantify the presence of carotid atherosclerosis in vivo These procedures have enabled the introduction of new concepts: (1) the degree of carotid stenosis is approxi- mate to the volume and extension of carotid plaque; and (2) a set of parameters, easily identifiable by com- puted tomography angiography, magnetic resonance angiogram and ultra-sound echo-color Doppler, are closely linked to the development of ischemic symptoms and can significantly increase the risk of stroke regard- less of the degree of stenosis. In light of these findings vulnerable plaques should be identified early, and the role of Digital Subtraction Angiography which is a purely technical luminal technique should be determined. 展开更多
关键词 CAROTID ARTERIES COMPUTED tomography an- giography Digital subtraction ANGIOGRAPHY
暂未订购
Robust background subtraction in traffic video sequence 被引量:6
11
作者 高韬 刘正光 +3 位作者 岳士弘 张军 梅建强 高文春 《Journal of Central South University》 SCIE EI CAS 2010年第1期187-195,共9页
For intelligent transportation surveillance, a novel background model based on Mart wavelet kernel and a background subtraction technique based on binary discrete wavelet transforms were introduced. The background mod... For intelligent transportation surveillance, a novel background model based on Mart wavelet kernel and a background subtraction technique based on binary discrete wavelet transforms were introduced. The background model kept a sample of intensity values for each pixel in the image and used this sample to estimate the probability density function of the pixel intensity. The density function was estimated using a new Marr wavelet kernel density estimation technique. Since this approach was quite general, the model could approximate any distribution for the pixel intensity without any assumptions about the underlying distribution shape. The background and current frame were transformed in the binary discrete wavelet domain, and background subtraction was performed in each sub-band. After obtaining the foreground, shadow was eliminated by an edge detection method. Experimental results show that the proposed method produces good results with much lower computational complexity and effectively extracts the moving objects with accuracy ratio higher than 90%, indicating that the proposed method is an effective algorithm for intelligent transportation system. 展开更多
关键词 background modeling background subtraction Marr wavelet binary discrete wavelet transform shadow elimination
在线阅读 下载PDF
Multiple subtraction method based on a non-causal matching filter 被引量:6
12
作者 Liu Hua-Feng Chen Xiao-Hong +1 位作者 Song Jia-Wen Liu Guo-Chang 《Applied Geophysics》 SCIE CSCD 2011年第1期27-35,94,95,共11页
The filter operator used in normal multichannel matching filter is physically realizable.This filter operator only delays seismic data in the filtering process.A noncausal multichannel matching filter based on a least... The filter operator used in normal multichannel matching filter is physically realizable.This filter operator only delays seismic data in the filtering process.A noncausal multichannel matching filter based on a least squares criterion is proposed to resolve the problem in which predicted multiple model data is Iater than real data.The diferences between causal and noncausal multichannel matching filters are compared using a synthetic shot gather,which demonstrates the validity of the noncausal matching filter.In addition,a variable length sliding window which changes with ofset and layer velocity is proposed to solve the count of events increasing with increasing ofset in a fixed Iength sliding window.This variable length sliding window is also introduced into the modified and expanded multichannel matching filter.This method is applied to the Pluto1.5 synthetic data set.The benefits of the non.causal filter operator and variable length sliding window are demonstrated bv the good multiple attenuation result. 展开更多
关键词 MULTIPLE matching subtraction non-causal convolution operator variable length window
在线阅读 下载PDF
Use of digital subtraction angiography for assessment of digital replantation 被引量:5
13
作者 Liu-hong WANG Guang-qiang ZHANG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2012年第3期209-212,共4页
Objective: To assess the blood flow of the proper digital artery using digital subtraction angiography (DSA) in the early stage after replantation. Methods: From January 2006 to October 2010, 27 anastomosed arteries i... Objective: To assess the blood flow of the proper digital artery using digital subtraction angiography (DSA) in the early stage after replantation. Methods: From January 2006 to October 2010, 27 anastomosed arteries in 27 replanted digits were included in the study. The patients included nine males and four females. The patients received DSA at 48 to 96 h after digital replantation. Based on DSA image, the blood flow was classified into normal, slow-running, and flow-stopping types. The patients with normal digital blood flow were given continuous routine treatments; the patients with slow-running flow were given the conservative treatments, such as release of the tight dressings, removal of stitches, keeping warm, the use of massage, and the use of anticoagulants and anti-inflammatory drugs; the patients with flow-stopping received immediate surgical re-exploration. Results: In this series, 23 digits in 11 patients showed a normal blood flow, and these digits all survived. In one of 13 patients, two digits which displayed slow-running flow also survived after conservative treatments. In two of 13 patients, two digits showed flow stopping, with one surviving and one failing after re-exploration and arterial revision. Conclusions: The DSA can be used to assess the blood flow of the proper digital artery in the early stage after replantation. It provides essential information for salvaging the replanted finger. 展开更多
关键词 Digital subtraction angiography Proper digital artery REPLANTATION Blood flow
原文传递
Background Subtraction and Frame Difference Based Moving Object Detection for Real-Time Surveillance 被引量:5
14
作者 黄中文 戚飞虎 岑峰 《Journal of Donghua University(English Edition)》 EI CAS 2003年第1期15-19,共5页
A new real-time algorithm is proposed in this paperfor detecting moving object in color image sequencestaken from stationary cameras.This algorithm combines a temporal difference with an adaptive background subtractio... A new real-time algorithm is proposed in this paperfor detecting moving object in color image sequencestaken from stationary cameras.This algorithm combines a temporal difference with an adaptive background subtraction where the combination is novel.Ⅷ1en changes OCCUr.the background is automatically adapted to suit the new conditions.Forthe background model,a new model is proposed with each frame decomposed into regions and the model is based not only upon single pixel but also on the characteristic of a region.The hybrid presentationincludes a model for single pixel information and a model for the pixel’s neighboring area information.This new model of background can both improve the accuracy of segmentation due to that spatialinformation is taken into account and salientl5r speed up the processing procedure because porlion of neighboring pixel call be selected into modeling.The algorithm was successfully used in a video surveillance systern and the experiment result showsit call obtain a clearer foreground than the singleframe difference or background subtraction method. 展开更多
关键词 video surveillance background subtraction frame differencing
在线阅读 下载PDF
SPEECH ENHANCEMENT USING CONSTRAINED SPECTRAL AMPLITUDE SUBTRACTION BASED ON NONCAUSAL A PRIORI SNR 被引量:3
15
作者 Wu Hongwei Wu Zhenyang 《Journal of Electronics(China)》 2006年第6期937-942,共6页
Two gain forms of spectral amplitude subtraction are derived theoretically without neglecting the correlation of speech and noise spectrum during the period of a fralne. In the implementation, the constrained gain is ... Two gain forms of spectral amplitude subtraction are derived theoretically without neglecting the correlation of speech and noise spectrum during the period of a fralne. In the implementation, the constrained gain is expressed as a function of noncausal a priori SNR (Signal-to-Noise Ratio). Noise and noncausal a priori SNR are estimated from the multitaper spectrum of the noisy signal with algorithms modified to be suitable for the multitaper spectruln. Objective evaluations show that in case of white Gaussian noise the proposed method outperforms some methods based on LSA (Log Spectral Amplitude) in terms of MBSD (Modified Bark Spectral Distortion), segmental SNR and overall SNR, and informal listening tests show that speech reconstructed in this way has little speech distortion and musical noise is nearly inaudible even at low SNR. 展开更多
关键词 Speech cnhancement Spectral amplitude subtraction Noise estimation Multitaper spectrum
在线阅读 下载PDF
Single-Channel Speech Enhancement Based on Improved Frame-Iterative Spectral Subtraction in the Modulation Domain 被引量:2
16
作者 Chao Li Ting Jiang Sheng Wu 《China Communications》 SCIE CSCD 2021年第9期100-115,共16页
Aiming at the problem of music noise introduced by classical spectral subtraction,a shorttime modulation domain(STM)spectral subtraction method has been successfully applied for singlechannel speech enhancement.Howeve... Aiming at the problem of music noise introduced by classical spectral subtraction,a shorttime modulation domain(STM)spectral subtraction method has been successfully applied for singlechannel speech enhancement.However,due to the inaccurate voice activity detection(VAD),the residual music noise and enhanced performance still need to be further improved,especially in the low signal to noise ratio(SNR)scenarios.To address this issue,an improved frame iterative spectral subtraction in the STM domain(IMModSSub)is proposed.More specifically,with the inter-frame correlation,the noise subtraction is directly applied to handle the noisy signal for each frame in the STM domain.Then,the noisy signal is classified into speech or silence frames based on a predefined threshold of segmented SNR.With these classification results,a corresponding mask function is developed for noisy speech after noise subtraction.Finally,exploiting the increased sparsity of speech signal in the modulation domain,the orthogonal matching pursuit(OMP)technique is employed to the speech frames for improving the speech quality and intelligibility.The effectiveness of the proposed method is evaluated with three types of noise,including white noise,pink noise,and hfchannel noise.The obtained results show that the proposed method outperforms some established baselines at lower SNRs(-5 to +5 dB). 展开更多
关键词 short-time modulation domain single-channel speech enhancement modulation improved frame iterative spectral subtraction low SNRs
在线阅读 下载PDF
Carbon dioxide digital subtraction angiography manifestations of hepa-tocellular carcinoma 被引量:2
17
作者 卢伟 李彦豪 +3 位作者 何晓峰 陈勇 曾庆乐 许小立 《Journal of Medical Colleges of PLA(China)》 CAS 2002年第1期60-64,共5页
Objective: To investigate the imaging features and clinical significance of carbon dioxide digital subtraction angiography (CO2-DSA) in the diagnosis and treatment of hepatocellular carcinoma (HCC). Methods: Both CO2-... Objective: To investigate the imaging features and clinical significance of carbon dioxide digital subtraction angiography (CO2-DSA) in the diagnosis and treatment of hepatocellular carcinoma (HCC). Methods: Both CO2-DSA and conventional DSA were performed in all 47 patients with HCC, and the angio-graphic manifestations of CO2-DSA were compared with those of conventional DSA in the same patients. Results: Peripheral arterial and capillary imaging by CO2-DSA was inferior to that by conventional DSA, although blood pools were well visualized with CO2. Improved visualization of arterioportal shunting (APS) was obtained with CO2-DSA compared with that by conventional angiography. APS was observed in 33 cases by CO2-DSA and in 12 cases by conventional angiography (P<0. 001). Retrograde visualization of the portal vein (PV) trunk and its large branches was demonstrated in 16 cases by CO2-DSA and in 1 case by conventional DSA (P<0. 001). The manifestation of lipiodol retention in the tumors was consistent with CO2-DSA images after TAE in 38 cases, and with those of conventional DSA in 23 cases (P<0. 01). Conclusion: CO2-DSA was superior to conventional DSA in the detection of APS and retrograde visualization of PV system, and the former can provide usefulness information for the treatment planning (chemoembolization) and patient prognosis. Demonstration of APS by CO2-DSA may suggest the presence of intrahepatic metastases. 展开更多
关键词 carbon dioxide digital subtraction angiography hepatocellular carcinoma arterioportal shunting
暂未订购
Noise Removal in Speech Processing Using Spectral Subtraction 被引量:5
18
作者 Marc Karam Hasan F. Khazaal +1 位作者 Heshmat Aglan Cliston Cole 《Journal of Signal and Information Processing》 2014年第2期32-41,共10页
Spectral subtraction is used in this research as a method to remove noise from noisy speech signals in the frequency domain. This method consists of computing the spectrum of the noisy speech using the Fast Fourier Tr... Spectral subtraction is used in this research as a method to remove noise from noisy speech signals in the frequency domain. This method consists of computing the spectrum of the noisy speech using the Fast Fourier Transform (FFT) and subtracting the average magnitude of the noise spectrum from the noisy speech spectrum. We applied spectral subtraction to the speech signal “Real graph”. A digital audio recorder system embedded in a personal computer was used to sample the speech signal “Real graph” to which we digitally added vacuum cleaner noise. The noise removal algorithm was implemented using Matlab software by storing the noisy speech data into Hanning time-widowed half-overlapped data buffers, computing the corresponding spectrums using the FFT, removing the noise from the noisy speech, and reconstructing the speech back into the time domain using the inverse Fast Fourier Transform (IFFT). The performance of the algorithm was evaluated by calculating the Speech to Noise Ratio (SNR). Frame averaging was introduced as an optional technique that could improve the SNR. Seventeen different configurations with various lengths of the Hanning time windows, various degrees of data buffers overlapping, and various numbers of frames to be averaged were investigated in view of improving the SNR. Results showed that using one-fourth overlapped data buffers with 128 points Hanning windows and no frames averaging leads to the best performance in removing noise from the noisy speech. 展开更多
关键词 SPEECH Processing Spectral subtraction Noise Removal FAST FOURIER TRANSFORM INVERSE FAST FOURIER TRANSFORM
在线阅读 下载PDF
Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients 被引量:1
19
作者 Seung-Jae Hyun Yongjung J Kim Seung-Chul Rhim 《World Journal of Clinical Cases》 SCIE 2013年第8期242-248,共7页
In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Pet... In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The longterm overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. 展开更多
关键词 SAGITTAL imbalance PEDICLE subtraction OSTEOTOMY Clinical outcome Proximal JUNCTIONAL KYPHOSIS Complication
暂未订购
Modified magnetic resonance angiography of the liver using sensitivity encoding in comparison with digital subtraction angiography and CT arterial portography 被引量:1
20
作者 Masahiko Fujii Hideaki Kawamitsu Kazuro Sugimura 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期185-191,共7页
BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgi... BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgical plan- ning or even precluded the necessity of surgery. Here we report our preliminary results of modified magnetic reso- nance angiography ( MRA ) using sensitivity encoding ( SENSE) through comparative study with conventional digital subtraction angiography (DSA) and CT arterial por- tography (CTAP). METHODS: Sixteen patients with suspected liver diseases were included in the study. All of them received both dy- namic MRI of the liver using SENSE and digital DSA with CTAP within a two-week interval. The four-phase MRA was reconstructed from source images of the coronal dy- namic study. The arterial phase of the modified MRA was compared with DSA in the evaluation of hepatic arteries and the portal phase compared with CT portography recon- structed from source images of CTAP. In dynamic study of the liver, a fixed dose (20 ml) of contrast medium and scan timing were used. RESULTS: The main branches and variations of the hepatic arterial system were well shown on the modified MRA, al- though the marginal branches of hepatic arteries were of poor quality. The figures of portal veins on MRA were as clear as or superior to those of CTAP. In addition, the su- prarenal inferior vena cava (IVC) was well demonstrated on MRA and/or non contrast-enhanced coronal balanced fast-field echo (b-FFE) scan sequence in most cases. MRI detected most parenchymal lesions of the liver and hemo- dynamics of these lesions could be evaluated on source ima- ges of the modified MRA. MRI/MRA also serendipitously revealed several extrahepatic disease entities or variations that were not found on DSA/CTAP. CONCLUSIONS: The modified MRA using SENSE is a cost-effective modality of examination for the demonstra- tion of the whole hepatic vascular system. Combined with MRI, it has the potential as a one-stop imaging modality in the preoperative evaluation in fields such as OLT. 展开更多
关键词 orthotopic liver transplantation magnetic resonance imaging magnetic resonance angiography digital subtraction angiography
暂未订购
上一页 1 2 16 下一页 到第
使用帮助 返回顶部