期刊文献+
共找到273篇文章
< 1 2 14 >
每页显示 20 50 100
High-precision RCS measurement of aircraft's weak scattering source 被引量:8
1
作者 Hu Chufeng Li Nanjing +1 位作者 Chen Weijun Zhang Linxi 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2016年第3期772-778,共7页
The radar cross section (RCS) of weak scattering source on the surface of an aircraft is usually less than -40 dBsm. How to accurately measure the RCS characteristics of weak scattering source is a technical challen... The radar cross section (RCS) of weak scattering source on the surface of an aircraft is usually less than -40 dBsm. How to accurately measure the RCS characteristics of weak scattering source is a technical challenge for the aircraft's RCS measurement. This paper proposes separating and extracting the two-dimensional (2D) reflectivity distribution of the weak scattering source with the microwave imaging algorithm and spectral transform so as to enhance its measurement preci- sion. Firstly, we performed the 2D microwave imaging of the target and then used the 2D gating function to separate and extract the reflectivity distribution of the weak scattering source. Secondly, we carried out the spectral transform of the reflectivity distribution and eventually obtained the RCS of the weak scattering source through calibration. The prototype experimental results and their analysis show that the measurement method is effective. The experiments on an aircraft's low-scattering conformal antenna verify that the measurement method can eliminate the clutter on the surface of aircraft. The precision of measuring a -40 dBsm target is 3 5 dB better than the existing RCS measurement methods. The measurement method can more accurately obtain the weak scattering source's RCS characteristics. 展开更多
关键词 Microwave imaging RCS measurement Reftectivity distributionSpectral transform Weak scattering source
原文传递
Region-of-interest micro-focus computed tomography based on an all-optical inverse Compton scattering source 被引量:3
2
作者 Yue Ma Jianfei Hua +10 位作者 Dexiang Liu Yunxiao He Tianliang Zhang Jiucheng Chen Fan Yang Xiaonan Ning Zhongshan Yang Jie Zhang Chih-Hao Pai Yuqiu Gu Wei Lu 《Matter and Radiation at Extremes》 SCIE CAS 2020年第6期36-41,共6页
Micro-focus computed tomography(CT),which allows the hyperfine structure within objects to be reconstructed,is a powerful nondestructive testing tool in many fields.However,current x-ray sources for micro-focus CT are... Micro-focus computed tomography(CT),which allows the hyperfine structure within objects to be reconstructed,is a powerful nondestructive testing tool in many fields.However,current x-ray sources for micro-focus CT are typically limited by their relatively low photon energy and low flux.An all-optical inverse Compton scattering source(AOCS)based on laser wakefield acceleration can generate intense quasi-monoenergetic x/gamma-ray pulses in the kilo-to megaelectronvolt range with micrometer-level source size,and its potential application for micro-focus CT has become very attractive in recent years because of the rapid progress made in laser wakefield acceleration.Reported here is a successful experimental demonstration of high-fidelity micro-focus CT using an AOCS(∼70 keV)by imaging and reconstructing a test object with complex inner structures.A region-of-interest CT method is adopted to utilize the relatively small field of view of the AOCS to ensure high spatial resolution.This demonstration of AOCS-based region-of-interest micro-focus CT is a key step toward its application in the field of hyperfine nondestructive testing. 展开更多
关键词 scattering optical source
在线阅读 下载PDF
Solving Non-Isospectral mKdV Equation and Sine-Gordon Equation Hierarchies with Self-Consistent Sources via Inverse Scattering Transform 被引量:2
3
作者 李琪 张大军 陈登远 《Communications in Theoretical Physics》 SCIE CAS CSCD 2010年第8期219-228,共10页
N-soliton solutions of the hierarchy of non-isospectral mKdV equation with self-consistent sources andthe hierarchy of non-isospectral sine-Gordon equation with self-consistent sources are obtained via the inverse sca... N-soliton solutions of the hierarchy of non-isospectral mKdV equation with self-consistent sources andthe hierarchy of non-isospectral sine-Gordon equation with self-consistent sources are obtained via the inverse scatteringtransform. 展开更多
关键词 the non-isospectral mKdV equation with self-consistent sources the non-isospectral sine-Gordon equation with self-consistent sources the inverse scattering transform exact solutions
在线阅读 下载PDF
Blind Source Separation based on Time-Frequency Morphological Characteristics for Rigid Acoustic Scattering by Underwater Objects 被引量:1
4
作者 Yang Yang Xiukun Li 《Journal of Marine Science and Application》 CSCD 2016年第2期201-207,共7页
Separation of the components of rigid acoustic scattering by underwater objects is essential in obtaining the structural characteristics of such objects. To overcome the problem of rigid structures appearing to have t... Separation of the components of rigid acoustic scattering by underwater objects is essential in obtaining the structural characteristics of such objects. To overcome the problem of rigid structures appearing to have the same spectral structure in the time domain, time-frequency Blind Source Separation (BSS) can be used in combination with image morphology to separate the rigid scattering components of different objects. Based on a highlight model, the separation of the rigid scattering structure of objects with time-frequency distribution is deduced. Using a morphological filter, different characteristics in a Wigner-Ville Distribution (WVD) observed for single auto term and cross terms can be simplified to remove any cross-term interference. By selecting time and frequency points of the auto terms signal, the accuracy of BSS can be improved. A simulation experimental has been used to analyze the feasibility of the new method, with changing the pulse width of the transmitted signal, the relative amplitude and the time delay parameter. And simulation results show that the new method can not only separate rigid scattering components, but can also separate the components when elastic scattering and rigid scattering exist at the same time. Experimental results confirm that the new method can be used in separating the rigid scattering structure of underwater objects. 展开更多
关键词 underwater object highlight structure rigid scattering components image morphology TIME-FREQUENCY blind source separation
在线阅读 下载PDF
Scattering of Solitons of Modified KdV Equation with Self-consistent Sources 被引量:1
5
作者 ZHANG Da-Jun WU Hua 《Communications in Theoretical Physics》 SCIE CAS CSCD 2008年第4期809-814,共6页
This paper investigates in detail the dynamics of the modified KdV equation with self-consistent sources, including characteristics of one-soliton, scattering conditions and phase shifts of two solitons, degenerate ca... This paper investigates in detail the dynamics of the modified KdV equation with self-consistent sources, including characteristics of one-soliton, scattering conditions and phase shifts of two solitons, degenerate case of two solitons and "ghost" solitons, etc. Co-moving coordinate frames are employed in asymptotic analysis. 展开更多
关键词 modified kdV equation with self-consistent source soliton scattering
在线阅读 下载PDF
Numerical simulation for all-optical Thomson scattering X-ray source
6
作者 谭放 朱斌 +5 位作者 韩丹 辛建婷 赵宗清 曹磊峰 谷渝秋 张保汉 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期249-255,共7页
Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-... Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-I laser system (800 nm, 30 fs, 300 TW) and the previous wakefield acceleration experimental results. The simulation results show that X-ray pulses with a duration of 30 fs and an emission angle of 50 mrad can be produced from such a source. Using the optimized electron parameters, X-ray pulses with better directivity and narrower energy spectra can be obtained. Besides the electron parameters, the laser parameters such as the wavelength, pulse duration, and spot size also affect the X-ray yield, the angular distribution, and the maximum photon energy, except the X-ray pulse duration which is slightly changed for the case of ultrafast laser-electron interaction. 展开更多
关键词 ultrashort laser wakefield acceleration Thomson scattering X-ray source
原文传递
Reconstruction Parameters of Local Scattering Sources of a Metallic Strip from the Backscattering Pattern
7
作者 Stanislav N. Kutishchev 《Journal of Electromagnetic Analysis and Applications》 2012年第12期492-496,共5页
In this paper, it is proved the ability of quantity reconstruction, amplitudes and coordinates of metallic strip local scattering sources from the backscattering pattern. They are performed as the results of numerical... In this paper, it is proved the ability of quantity reconstruction, amplitudes and coordinates of metallic strip local scattering sources from the backscattering pattern. They are performed as the results of numerical solution for the infinite perfect conducting strip in case of E-polarization of the incident plane electromagnetic wave. In this case it is necessary to fulfill the following conditions. The local sources amplitudes should be the same order, in transverse and longitudinal directions the local sources should be separated into distances more than apparatus resolution, and the object maximum size does not have to be more than approximately 50λ. It was shown the limit and ability of the further development of the offered method. 展开更多
关键词 BACKscattering PATTERN Local scattering sourceS Radar Image Electromagnetic Wave Method METALLIC STRIP
暂未订购
High-brightness photo-injector with standing-wave buncher-based ballistic bunching scheme for inverse Compton scattering light source
8
作者 Jian-Xin Wang Kui Zhou +7 位作者 Peng Li De-Xin Xiao Li-Jun Shan Xu-Ming Shen Yu Liu Zheng Zhou Han-Bin Wang Dai Wu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第4期51-61,共11页
We report our recent progress in the design and simulation of a high-brightness S-band photo-injector with a ballistic bunching scheme aimed at driving an inverse Compton scattering(ICS)X-ray source.By adding a short ... We report our recent progress in the design and simulation of a high-brightness S-band photo-injector with a ballistic bunching scheme aimed at driving an inverse Compton scattering(ICS)X-ray source.By adding a short standing-wave buncher between the RF gun and first booster in a conventional S-band photo-injector,electron bunches with a 500 pC charge can be compressed to the sub-picosecond level with very limited input RF power and an unchanged basic layout of the photo-injector.Beam dynamics analysis indicates that fine tuning of the focusing strength of the gun and linac solenoid can well balance additional focusing provided by the standing wave buncher and generate a well-compensated transverse emittance.Thorough bunching dynamics simulations with different operating conditions of the buncher show that a buncher with more cells and a moderate gradient is suitable for simultaneously obtaining a short bunch duration and low emittance.In a typical case of a 9-cell buncher with a 38 MV/m gradient,an ultrashort bunch duration of 0.5 ps(corresponding to a compression ratio of>5)and a low emittance of<1 mm mrad can be readily obtained for a 500 pC electron pulse.This feasible ballistic bunching scheme will facilitate the implementation of an ultrashort pulse mode inverse Compton scattering X-ray source on most existing S-band photo-injectors. 展开更多
关键词 Beam brightness Ballistic bunching Emittance compensation Compton scattering X-ray source
在线阅读 下载PDF
INVERSE SCATTERING PROBLEMS BY SINGULAR SOURCE METHODS
9
作者 刘继军 《Numerical Mathematics A Journal of Chinese Universities(English Series)》 SCIE 2005年第3期193-207,共15页
The inverse scattering problems are to detect the property of obstacles from the measurements outside the obstacles. One of important research areas in this topic is the recovery of boundary property for impenetrable ... The inverse scattering problems are to detect the property of obstacles from the measurements outside the obstacles. One of important research areas in this topic is the recovery of boundary property for impenetrable obstacles. In this paper, we would like to give a brief review about the recently developed singular source methods. There are three different methods in this category, namely, linear sampling method, pointsource method and probe method. We also present some recent new results about the probe method. 展开更多
关键词 反转散射 HELMHOLTZ方程 叠加法 边界问题
在线阅读 下载PDF
Tip-enhanced Raman scattering of glucose molecules 被引量:3
10
作者 Zhonglin Xie Chao Meng +3 位作者 Donghua Yue Lei Xu Ting Mei Wending Zhang 《Opto-Electronic Science》 2025年第5期2-9,共8页
Glucose molecules are of great significance being one of the most important molecules in metabolic chain.However,due to the small Raman scattering cross-section and weak/non-adsorption on bare metals,accurately obtain... Glucose molecules are of great significance being one of the most important molecules in metabolic chain.However,due to the small Raman scattering cross-section and weak/non-adsorption on bare metals,accurately obtaining their"fingerprint information"remains a huge obstacle.Herein,we developed a tip-enhanced Raman scattering(TERS)technique to address this challenge.Adopting an optical fiber radial vector mode internally illuminates the plasmonic fiber tip to effectively suppress the background noise while generating a strong electric-field enhanced tip hotspot.Furthermore,the tip hotspot approaching the glucose molecules was manipulated via the shear-force feedback to provide more freedom for selecting substrates.Consequently,our TERS technique achieves the visualization of all Raman modes of glucose molecules within spectral window of 400-3200 cm^(-1),which is not achievable through the far-field/surface-enhanced Raman,or the existing TERS techniques.Our TERS technique offers a powerful tool for accurately identifying Raman scattering of molecules,paving the way for biomolecular analysis. 展开更多
关键词 tip-enhanced Raman scattering scanning near-field optical microscope fiber vector light field tip nanofocusing light source
在线阅读 下载PDF
Study of the elastic scattering effects of a slowing-down model on D–T neutron porosity logging
11
作者 Shao-Heng Zhou Ying-Long Tao +6 位作者 Bo Chang Li-Juan Hao Jie-Qiong Jiang Ya-Zhou Li Fang Wang Quan Gan FDS Consortium 《Nuclear Science and Techniques》 2025年第5期206-215,共10页
The application of a controllable neutron source for measuring formation porosity in the advancement of nuclear logging has garnered increased attention.The existing porosity algorithm,which is based on the thermal ne... The application of a controllable neutron source for measuring formation porosity in the advancement of nuclear logging has garnered increased attention.The existing porosity algorithm,which is based on the thermal neutron counting ratio,exhibits lower sensitivity in high-porosity regions.To enhance the sensitivity,the effects of elastic and inelastic scattering,which influence the slowing-down of fast neutrons,were theoretically analyzed,and a slowing-down model of fast neutrons was created.Based on this model,a density correction porosity algorithm was proposed based on the relationship between density,thermal neutron counting ratio,and porosity.Finally,the super multifunctional calculation program for nuclear design and safety evaluation(TopMC/SuperMC)was used to create a simulation model for porosity logging,and its applicability was examined.The results demonstrated that the relative error between the calculated and actual porosities was less than 1%,and the influence of deviation in the density measurement was less than 2%.Therefore,the proposed density correction algorithm based on the slowing-down model of fast neutrons can effectively improve the sensitivity in the high-porosity region.This study is expected to serve as a reference for the application of neutron porosity measurements with D–T neutron sources. 展开更多
关键词 D–T neutron source Slowing-down model Elastic scattering Neutron porosity
在线阅读 下载PDF
Numerical study of scattering Legendre moments and effect of anisotropic scattering on S_N shielding calculation 被引量:1
12
作者 Cong Liu Xiao-Li Hu +3 位作者 Bin Zhang You Gong Liang Zhang Yi-Xue Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第11期95-107,共13页
In neutron and photon transport problems,anisotropic scattering is of great importance for the particle flux,especially when the angular flux has a strong forward peak in shielding analyses.The conventional Legendre e... In neutron and photon transport problems,anisotropic scattering is of great importance for the particle flux,especially when the angular flux has a strong forward peak in shielding analyses.The conventional Legendre expansion is widely used in discrete ordinates transport codes because of algebraic simplifications with spherical harmonics for the scattering source.However,negative cross sections caused by the finitely truncated expansion may give rise to a negative source and flux.A simple method is adopted,based on integrating functions of scattering moments,to evaluate anisotropy and convergence of expanded functions.A series of problems were designed with angular fluxes of different anisotropy,and numerical simulations were performed using the ARES transport code to study different treatments and algorithms for scattering.Results show that the diagonal transport approximation is more stable and obtains a similar accuracy with the extended approximation.A conservative fixup for the negative source could ensure particle balance and improve computational accuracy significantly for photon transport.The effect of anisotropic scattering is problem-dependent,and no distinct differences among various methods are observed for volume source problems with a continuous energy source.For beam source problems,flux results are sensitive to negative scattering functions,and strictly nonnegative cross sections need to be implemented. 展开更多
关键词 Particle TRANSPORT SHIELDING calculation Discrete ordinates method ANISOTROPIC scattering TRANSPORT approximation NEGATIVE source fix-up
在线阅读 下载PDF
Exact Solutions of Ablowitz–Ladik Hierarchy with Self-Consistent Sources Revisited and Reductions
13
作者 李琪 段求员 +1 位作者 陈登远 张建兵 《Communications in Theoretical Physics》 SCIE CAS CSCD 2014年第7期5-12,共8页
In the paper, Ablowitz–Ladik hierarchy with new self-consistent sources is investigated. First the source in the hierarchy is described as φnφn+1, where φnis related to the Ablowitz–Ladik spectral problem, instea... In the paper, Ablowitz–Ladik hierarchy with new self-consistent sources is investigated. First the source in the hierarchy is described as φnφn+1, where φnis related to the Ablowitz–Ladik spectral problem, instead of the corresponding adjoint spectral problem. Then by means of the inverse scattering transform, the multi-soliton solutions for the hierarchy are obtained. Two reductions to the discrete mKdV and nonlinear Schr¨odinger hierarchies with selfconsistent sources are considered by using the uniqueness of the Jost functions, as well as their N-soliton solutions. 展开更多
关键词 Ablowitz–Ladik HIERARCHY with SELF-CONSISTENT sourceS DISCRETE nonlinear Schr¨odinger HIERARCHY with SELF-CONSISTENT sourceS DISCRETE MKDV HIERARCHY with SELF-CONSISTENT sourceS inverse scattering transform multi-soliton solution
原文传递
A whole-space transform formula of cylindrical wave functions for scattering problems
14
作者 Yuan Xiaoming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期23-28,共6页
The theory of elastic wave scattering is a fundamental concept in the study of elastic dynamics and wave motion,and the wave function expansion technique has been widely used in many subjects.To supply the essential t... The theory of elastic wave scattering is a fundamental concept in the study of elastic dynamics and wave motion,and the wave function expansion technique has been widely used in many subjects.To supply the essential tools for solving wave scattering problems induced by an eccentric source or multi-sources as well as multi-scatters,a whole-space transform formula of cylindrical wave functions is presented and its applicability to some simple cases is demonstrated in this study.The transforms of wave functions in cylindrical coordinates can be classifi ed into two basic types: interior transform and exterior transform,and the existing Graf’s addition theorem is only suitable for the former.By performing a new replacement between the two coordinates,the exterior transform formula is fi rst deduced.It is then combined with Graf’s addition theorem to establish a whole-space transform formula.By using the whole-space transform formula,the scattering solutions by the sources outside and inside a cylindrical cavity are constructed as examples of its application.The effectiveness and advantages of the whole-space transform formula is illustrated by comparison with the approximate model based on a large cycle method.The whole-space transform formula presented herein can be used to perform the transform between two different cylindrical coordinates in the whole space.In addition,its concept and principle are universal and can be further extended to establish the coordinate transform formula of wave functions in other coordinate systems. 展开更多
关键词 scattering transform of wave functions whole-space transform eccentric source multi-sources multi-scatters
在线阅读 下载PDF
Seismoelectric waves in a borehole excited by an external explosive source
15
作者 周久光 崔志文 +2 位作者 吕伟国 张玉君 土克协 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第1期266-271,共6页
The conversion of energy between seismic and electromagnetic wave fields has been described by Pride's coupled equations in porous media. In this paper, the seismoelectric field excited by the explosive point sour... The conversion of energy between seismic and electromagnetic wave fields has been described by Pride's coupled equations in porous media. In this paper, the seismoelectric field excited by the explosive point source located at the outside of the borehole is studied. The scattering fields inside and outside a borehole are analyzed and deduced under the boundary conditions at the interface between fluid and porous media. The influences of the distance of the point source, multipole components of the eccentric explosive source, and the receiving position along the axis of vertical borehole, on the converted waves inside the borehole are all investigated. When the distance from the acoustic source to the axis of a borehole is far enough, the longitudinal and coseismic longitudinal wave packets dominate the acoustic and electric field, respectively. The three components of both electric field and magnetic field can be detected, and the radial electric field is mainly excited and converted by the dipole component. Owing to the existence of borehole, the electric fields and magnetic fields in the borehole are azimuthal. The distance from the point where the maximum amplitude of the axial components of electric field is recorded, to the origin of coordinate indicates the horizontal distance from the explosive source to the axis of vertical borehole. 展开更多
关键词 poroelastic wave BOREHOLE scattering field explosive source
原文传递
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
16
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 X-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering X-ray source Monte Carlo simulation
在线阅读 下载PDF
Numerical Investigation of a UCN Source Based on Solid Deuterium by Combining a Simulation Code with an Analytical Approach
17
作者 Habib Mohammadi Mohammad Mehdi Firoozabadi Rouhollah Gheisari 《Journal of Modern Physics》 2014年第17期1831-1838,共8页
At thermal ultra-cold neutron (UCN) sources (neutrons in thermal equilibrium with the moderator) only a very small fraction of neutrons have velocities ~6 m/s. Therefore, the UCN production rate cannot be substantiall... At thermal ultra-cold neutron (UCN) sources (neutrons in thermal equilibrium with the moderator) only a very small fraction of neutrons have velocities ~6 m/s. Therefore, the UCN production rate cannot be substantially increased by simply lowering the temperature of the moderator. The new approach is to use the super-thermal principle, i.e., neutrons not in thermal equilibrium with the converter. We want to investigate scattering kernels for a super-thermal UCN source based on a two-layer arrangement of D2O and solid D2. The solid D2 (sD2) at temperature 8 K is kept in close contact with D2O moderator at room temperature. Using the MCNP code, the fast neutron flux on the spallation target, the thermal flux in the D2O near the sD2, and the cold flux in the sD2 are simulated. For a given cold flux, neutron transport equations are calculated. In order to obtain precise neutron scattering kernels, and consequently UCN flux and density, 330 neutron energy groups have been taken. The coupled energy dependent transport equations have been solved by combining MCNPX code with an analytical approach and using implicit method in MATLAB. We have obtained an optimal dimension for the UCN source. A suitable space step has been taken for the numerical stability. 展开更多
关键词 Two-Layer UCN source Based on D2O/sD2 scattering Kernel MONTE Carlo METHOD IMPLICIT METHOD Super-Thermal Principle
在线阅读 下载PDF
Parasitic source resistance at different temperatures for AlGaN/AlN/GaN heterostructure field-effect transistors
18
作者 刘艳 林兆军 +5 位作者 吕元杰 崔鹏 付晨 韩瑞龙 霍宇 杨铭 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第9期389-395,共7页
The parasitic source resistance(RS) of AlGaN/AlN/GaN heterostructure field-effect transistors(HFETs) is studied in the temperature range 300–500 K. By using the measured RSand both capacitance–voltage(C–V) an... The parasitic source resistance(RS) of AlGaN/AlN/GaN heterostructure field-effect transistors(HFETs) is studied in the temperature range 300–500 K. By using the measured RSand both capacitance–voltage(C–V) and current–voltage(I–V) characteristics for the fabricated device at 300, 350, 400, 450, and 500 K, it is found that the polarization Coulomb field(PCF) scattering exhibits a significant impact on RSat the above-mentioned different temperatures. Furthermore, in the AlGaN/AlN/GaN HFETs, the interaction between the additional positive polarization charges underneath the gate contact and the additional negative polarization charges near the source Ohmic contact, which is related to the PCF scattering, is verified during the variable-temperature study of RS. 展开更多
关键词 AlGaN/AlN/Ga N heterostructure field-effect transistors(HFETs) parasitic source resistance polarization Coulomb field scattering
原文传递
Proposal for a high brightness γ-ray source at the SXFEL
19
作者 武海龙 陈建辉 +2 位作者 刘波 王东 赵振堂 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第5期11-19,共9页
High brightness γ-rays produced by laser Compton scattering(LCS) are ideal probes for the study of nucleon and nuclear structure. We propose such a γ-ray source using the backscattering of a laser from the bright el... High brightness γ-rays produced by laser Compton scattering(LCS) are ideal probes for the study of nucleon and nuclear structure. We propose such a γ-ray source using the backscattering of a laser from the bright electron beam produced by the linac of the Shanghai Soft X-ray Free-electron Laser(SXFEL) test facility at the Shanghai Institute of Applied Physics(SINAP). The performance is optimized through theoretical analysis and benchmarked with 4D Monte-Carlo simulations. The peak brightness of the source is expected to be larger than2 × 1022photons/(mm2mrad2s 0.1%BW) and photon energy ranges from 3.7 Me V to 38.9 Me V. Its performance, compared to Extreme Light Infrastructure-Nuclear Physics(ELI-NP), and the Shanghai Laser-Electron Gamma-ray Source(SLEGS), is given. The potential for basic and applied research is also briefly outlined. 展开更多
关键词 射线源 高亮度 激光产生 基础设施 康普顿散射 物理研究所 激光加速器 试验设备
在线阅读 下载PDF
Simulation study of a photo-injector for brightness improvement in Thomson scattering X-ray source via ballistic bunching 被引量:1
20
作者 丁云泽 杜应超 +1 位作者 张振 黄文会 《Chinese Physics C》 SCIE CAS CSCD 2014年第2期75-81,共7页
Increasing the peak brightness is beneficial to various applications of the Thomson scattering X-ray source. A higher peak brightness of the scattered X-ray pulse demands a shorter scattering electron beam realized by... Increasing the peak brightness is beneficial to various applications of the Thomson scattering X-ray source. A higher peak brightness of the scattered X-ray pulse demands a shorter scattering electron beam realized by beam compression in the electron beam-line. In this article, we study the possibility of compressing the electron beam in a typical S-band normal conducting photo-injector via ballistic bunching, through just adding a short RF linac section right behind the RF gun, so as to improve the peak brightness of the scattered x-ray pulse. Numerical optimization by ASTRA demonstrates that the peak current can increase from 50 A to 300 A for a 500 pC, 10 ps FWHM electron pulse, while normalized transverse RMS emittance and RMS energy spread increases very little. Correspondingly, the peak brightness of the Thomson scattering X-ray source is estimated to increase about three times. 展开更多
关键词 beam compression ballistic bunching Thomson scattering X-ray source
原文传递
上一页 1 2 14 下一页 到第
使用帮助 返回顶部