期刊文献+
共找到1,839篇文章
< 1 2 92 >
每页显示 20 50 100
Mechanical behaviors of steel reinforced ECC / concrete composite columns under combined vertical and horizontal loading 被引量:8
1
作者 单奇峰 潘金龙 陈俊涵 《Journal of Southeast University(English Edition)》 EI CAS 2015年第2期259-265,共7页
In order to improve the load capacity, seismic performance and performance-cost ratio of the columns, the concrete at the base of reinforced concrete (RC) columns is substituted with engineered cementitious composit... In order to improve the load capacity, seismic performance and performance-cost ratio of the columns, the concrete at the base of reinforced concrete (RC) columns is substituted with engineered cementitious composites (ECC) to form ECC/RC composite columns. Based on the existing material properties, the mechanical behaviors of the ECC columns, ECC/RC composite columns and RC columns were numerically studied under combined vertical and horizontal loading with the software of ATENA. Then, the failure mechanism of ECC columns and ECC/RC composite columns were comprehensively studied and compared with that of the RC columns. Then, the effects of the height of the ECC, the axial compression ratio, and the transverse reinforcement ratio on the mechanical behaviors of the composite or the ECC column are studied. The calculation results show that the ultimate load capacity, ductility and crack resistance of the ECC or ECC/RC composite columns are superior to those of the RC columns. The ECC/RC composite column with a height of the ECC layer of 1.2h ( h is the height of the cross section) can achieve similar mechanical properties of a full ECC column. With high shear strength, ECC can undertake the shear force and significantly reduce the amount of stirrups, avoiding construction issues and promoting its engineering application. 展开更多
关键词 engineered cementitious composites ECC ECC/RC composite columns compression-bending behavior numerical analysis parametric analysis
在线阅读 下载PDF
Liquefaction mitigation in silty soils using composite stone columns and dynamic compaction 被引量:4
2
作者 T.Shenthan R.Nashed +1 位作者 S.Thevanayagam G.R.Martin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2004年第1期39-50,共12页
The objective of this study is to develop an analytical methodology to evaluate the effectiveness of vibro stone column (S.C.) and dynamic compaction (D.C.) techniques supplemented with wick drains to densify and miti... The objective of this study is to develop an analytical methodology to evaluate the effectiveness of vibro stone column (S.C.) and dynamic compaction (D.C.) techniques supplemented with wick drains to densify and mitigate liquefaction in saturated sands and non-plastic silty soils. It includes the following: (i) develop numerical models to simulate and analyze soil densitication during S.C. installation and D.C. process, and (ii) identify parameters controlling post-improvement soil density in both cases, and (iii) develop design guidelines for densification of silty soils using the above techniques. An analytical procedure was developed and used to simulate soil response during S.C. and D.C. installations, and the results were compared with available case history data. Important construction design parameters and soil properties that affect the effectiveness of these techniques, and construction design choices suitable for sands and non-plastic silty soils were identified. The methodology is expected to advance the use of S.C. and D.C. in silty soils reducing the reliance on expensive field trials as a design tool. The ultimate outcome of this research will be design charts and design guidelines for using composite stone columns and composite dynamic compaction techniques in liquefaction mitigation of saturated silty soils. 展开更多
关键词 liquefaction mitigation silty soils composite stone columns dynamic compaction
在线阅读 下载PDF
Seismic behaviors of steel reinforced ECC/RC composite columns under low-cyclic loading 被引量:9
3
作者 Pan Jinlong Mo Chuang +1 位作者 Xu Li Chen Junhan 《Journal of Southeast University(English Edition)》 EI CAS 2017年第1期70-78,共9页
To improve the seismic performance of columns, engineered cementitious composite (ECC) is introduced to partially substitute concrete at the base of the columns to form ECC,/reinforced concrete ( RC) composite col... To improve the seismic performance of columns, engineered cementitious composite (ECC) is introduced to partially substitute concrete at the base of the columns to form ECC,/reinforced concrete ( RC) composite columns. The mechanical behaviors of the ECC/RC composite columns are numerically studied under low-cyclic loading with the finite element analysis softwareof MSC. MARC. It is found that the ECC/RC composite columns can significantly enhance the load capacity, the ductility ad energy dissipation of columns. Then, the effects of the height of the ECC, the axial compression ratio and the longitudinal reinforcement ratio on the seismic behaviors of the composite columns are parametrically studied. The results show that the ECC/RC composite column with a height of the ECC layer of 0. Sh(h is the height to the cross-section) can achieve similar seismic performance of a full ECC column. The peak load of the composite column increases significantly while the ductility decreases with the increase of the axial compression ratio. Increasing the longitudinal reinforcement ratio within a certain range can improve the ductility and energy dissipation capacity and almost has no effect on load capacity. The aalysis results ae instructive and valuable for reference in designing ECC structures. 展开更多
关键词 engineered cementitious composites ECC) ECC/RC composite columns hysteretic curves DUCTILITY energy dissipation parametric analysis
在线阅读 下载PDF
Mechanical Behavior of Rectangular Steel-Reinforced ECC/Concrete Composite Column under Eccentric Compression 被引量:3
4
作者 潘金龙 鲁冰 +2 位作者 顾大伟 夏正昊 夏天阳 《Transactions of Tianjin University》 EI CAS 2015年第3期269-277,共9页
In order to improve the seismic performance, deformation ability and ultimate load-carrying capacity of columns with rectangular cross section, engineered cementitious composite (ECC) is introduced to partially subs... In order to improve the seismic performance, deformation ability and ultimate load-carrying capacity of columns with rectangular cross section, engineered cementitious composite (ECC) is introduced to partially substitute concrete in the edge zone of reinforced concrete columns and form reinforced ECC/concrete composite columns. Firstly, based on the assumption of plane remaining plane and the simplified constitutive models, the calculation method of the load-carrying capacity of reinforced ECC/concrete columns is proposed. The stress and strain distribu- tions and crack propagation of the composite columns in different states of eccentric compressive loading are ana- lyzed. Then, nonlinear finite element analysis is conducted to study the mechanical performance of reinforced ECC/concrete composite columns with rectangular cross section. It is found that the simulation results are in good agreement with the theoretical results, indicating that the proposed method for calculating the load-carrying capacity of concrete/ECC composite columns is valid. Finally, based on the proposed method, the effects of ECC thickness, com- pressive strength of concrete and longitudinal reinforcement ratio on the mechanical performance of reinforced ECC/ concrete composite columns are analyzed. Calculation results indicate that increasing the thickness of ECC layer or longitudinal reinforcement ratio can effectively increase the ultimate load-carrying capacity of the composite column with both small and large eccentricity, but increasing the strength of concrete can only increase the ultimate Ioad- carrying capacity of the composite column with small eccentricity. 展开更多
关键词 engineered cementitious composite (ECC) steel-reinforced concrete ECC/concrete composite column eccentric compression behavior ultimate load-carrying capacity
在线阅读 下载PDF
Behavior of slender steel concrete composite columns in eccentric loading 被引量:1
5
作者 起根田 张孟喜 李永和 《Journal of Shanghai University(English Edition)》 CAS 2009年第6期481-488,共8页
Ten slender steel reinforced cencrete (SRC) composite columns are tested under eccentric loading conditions. Effects of concrete strength, slenderness of columns and eccentricity of the axial load are studied. The l... Ten slender steel reinforced cencrete (SRC) composite columns are tested under eccentric loading conditions. Effects of concrete strength, slenderness of columns and eccentricity of the axial load are studied. The load-carrying capacity is reduced with increased slenderness ratio and eccentricity. Concrete strength has no obvious influence on eccentrically loaded columns. Then, a nonlinear numerical method of pin-ended slender columns is also presented. This method is applicable for determining the material failure load or buckling failure load of a slender steel reinforced concrete composite column. In this method both material and geometric nonlinearities are taken into account. The results of numerical analysis accord well with the test results. The test results are also compared with the results predicted by ACI318-05 and the China Specifications. 展开更多
关键词 steel concrete composite column BEHAVIOR nonlinear analysis
在线阅读 下载PDF
Bearing capacity of composite columns reinforced by concrete filled steel tube 被引量:1
6
作者 韦建刚 ZHU Pu CHEN Bao-chun 《Journal of Chongqing University》 CAS 2013年第1期27-34,共8页
In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance ... In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance under axial or eccentric compression. The failure mode is characterized by the crush of the outer concrete. The bearing capacity increases at first and then decreases with further increase of the position coefficient. It can be concluded that position coefficient is an important structural parameter that has considerable influences on the ultimate bearing capacity of the composite columns. The outer concrete, steel tubes and longitudinal reinforcement are found to work in a cooperative manner under axial or eccentric compression when the position coefficient is about 0.5. An improved bearing capacity algorithm that takes the position coefficient into account has been proposed based on the experimental and simulation results and current technical specification in China. It has been proven to be precise and safe. 展开更多
关键词 concrete filled steel tube composite column position factor TEST FORMULA
在线阅读 下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
7
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
在线阅读 下载PDF
Comparison between Composite Column Using Limestone and Basalt Concrete 被引量:2
8
作者 Hamadallah Al-Baijat Andrea Benedetti 《Open Journal of Civil Engineering》 2013年第1期1-6,共6页
This research is conducted to study the experimental behavior of composite steel-concrete columns with basalt additives. Various percentages of basalt are added to the concrete mixes to investigate its effect on the t... This research is conducted to study the experimental behavior of composite steel-concrete columns with basalt additives. Various percentages of basalt are added to the concrete mixes to investigate its effect on the total axial compressive capacity of the columns. Expected failure scenarios of the columns are: concrete compressive failure, buckling of steel section, and de-bonding between steel and concrete sections. A conventional limestone composite column was used as base mix. The results of the study indicate a significant improvement in structural behavior and strength of the columns by increasing the percentage of basalt content. 展开更多
关键词 composite column BASALT MIX JORDAN
暂未订购
Seismic Behavior of Confined RC ColumnComposite Beam Joints
9
作者 张谦 于庆荣 +1 位作者 管俊峰 吴智敏 《Transactions of Tianjin University》 EI CAS 2014年第3期174-181,共8页
In order to evaluate the seismic behavior of confined RC column-composite beam joints, five interior joints were tested under low cyclic reversed load. The weakening extent of flanges, the number of studs, and whether... In order to evaluate the seismic behavior of confined RC column-composite beam joints, five interior joints were tested under low cyclic reversed load. The weakening extent of flanges, the number of studs, and whether to reinforce weakened flanges were used as parameters in designing these five joints. Failure characteristics, hysteretic curves, skeleton curves, ductility, energy dissipation, strength degradation, and stiffness degradation were analyzed. The test results revealed that the steel beam flanges in the joints were equivalent to the tie rod. Weakened flanges resulted in poor seismic behavior; however, the seismic behavior could be improved by increasing studs and reinforcing weakened flanges. The joint steel plate hoops, equivalent to stirrups, did not yield when the maximum load was reached, but yielded when the failure load was reached for the joints with shear failure. Increasing stud-type joints and reinforcing flange-type joints ensured good seismic behavior and met project requirements. Based on the experimental results, the failure mechanism of the joints was discussed, and the shear capacity equations of the joints was presented. 展开更多
关键词 seismic behavior JOINT confined RC column composite beam
在线阅读 下载PDF
An Experimental Study of Composite Columns Filled with Eucalyptus nitens Timber under Axial Compression
10
作者 Yingyao Cheng Xudong Chen +2 位作者 Huaming An Huimin Wang Kai Tao 《Journal of Renewable Materials》 SCIE EI 2023年第2期825-836,共12页
Eucalyptus nitens(E.nitens)has been much used for producing paper but also shows promise for structural applications.In this study,static compressive tests were undertaken to examine its suitability to be used in an i... Eucalyptus nitens(E.nitens)has been much used for producing paper but also shows promise for structural applications.In this study,static compressive tests were undertaken to examine its suitability to be used in an innovative composite column.The composite column was comprised of a rectangular steel tube with E.nitens timber infill.The nonlinear compressive behaviour of the composite column filled with E.nitens wood for both dry and wet conditions was examined.The same tests on rectangular steel tubes and bare dry and wet E.nitens samples were also undertaken as a comparison.For samples with different conditions,the ultimate capacity was evaluated and the effect of each condition on the compressive behaviour of the composite column was clarified.The steel tubes showed greater ductile behaviour,and more ductility was found in the wet samples.The steel tubes with E.nitens timber infill samples exhibited a greater linear elastic range connected with higher maximum loads,while the bare timber samples could support only lower maximum loads.The results from this research were promising for the use of rectangular steel tubes with E.nitens timber infill in structural applications. 展开更多
关键词 Hollow steel tubes EUCALYPTUS high moisture content composite column with timber infill compression
在线阅读 下载PDF
Numerical Modeling on Seismic Performance of Castellated Composite Beam⁃Reinforced Concrete Column Connection
11
作者 Hongwei Ma Junjie Wang Yang Wang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2021年第2期62-73,共12页
The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real condition... The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real conditions,a beam⁃through⁃type beam⁃column connection is proposed.Two 1/2⁃scaled connection specimens were tested and three⁃dimensional finite element models of the beam⁃column connection were set up.The longitudinal reinforcements,concrete beam,and column were simulated by link and solid elements,respectively.The influences of the parameters such as expansion ratio,location of web opening,and original height of steel beam were studied.The results show that connections possessed high initial rigidity.The expansion ratio of steel beam showed more important influence on the connection’s ultimate bearing capacity.For the connection models with steel beam expansion ratio of 1.4,the maximum increment of the ultimate bearing capacity of the connection could reach 28%.In order to prevent the local buckling failure of steel beam from occurring near web opening,the expansion ratio of steel beam should not be greater than 1.3. 展开更多
关键词 castellated composite beam beam⁃column connection finite element analysis expansion ratio
在线阅读 下载PDF
Evaluation of Current Design Practices on Estimation of Axial Capacity of Concrete Encased Steel Composite Stub Columns: A Review
12
作者 Amiya Kumar Samanta Amit Paul 《Journal of Civil Engineering and Architecture》 2013年第9期1080-1091,共12页
This paper presents the design assessment of concrete encased I-sections composite column based approaches given in Eurocode, ACI Code, BS Code and AISC-LRFD. This study includes comparison of various design parameter... This paper presents the design assessment of concrete encased I-sections composite column based approaches given in Eurocode, ACI Code, BS Code and AISC-LRFD. This study includes comparison of various design parameters and evaluation of design strength based on the procedures predicted in the various codes of practices. A practical example has been assumed and calculation has been shown to evaluate their potentiality in understanding in predicting the potentiality of various procedures. The obtained results based on the methods varies widely, because of the different design considerations adopted by the different codes. As such, they have hardly considered the effect of confinement of the concrete due to the presence of longitudinal reinforcements as well as lateral ties. The study has attempted to throw light on critical review and their potentiality in assessing the strength of such concrete encased composite column under purely axial loads. 展开更多
关键词 Concrete encased structural steel composite column design philosophy.
在线阅读 下载PDF
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
13
作者 郜京峰 张耀春 +2 位作者 王海明 姚淇誉 金路 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期91-102,共12页
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ... A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints. 展开更多
关键词 SEMI-RIGID thin-walled steel-concrete composite structures beam-to-column joints static behavior experimental study
在线阅读 下载PDF
Consolidation solution for composite foundation considering a time-and depth-dependent stress increment along with three distribution patterns of soil permeability 被引量:4
14
作者 Meng-meng LU Kang-he XIE +1 位作者 Chuan-xun LI Kun WANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2011年第4期268-277,共10页
In actual engineering practice,the stress increment within a composite foundation caused by external loads may vary simultaneously with depth and time.In addition,column installation always leads to a decay of soil pe... In actual engineering practice,the stress increment within a composite foundation caused by external loads may vary simultaneously with depth and time.In addition,column installation always leads to a decay of soil permeability towards the column.However,almost none of the consolidation theories for composite foundation comprehensively consider these factors until now.For this reason,a stress increment due to external loads changing simultaneously with time and depth was incorporated into the analysis,and three possible variation patterns of soil's horizontal permeability coefficient were considered to account for the detrimental influence of column installation.These three patterns included a constant distribution pattern(Pattern I),a linear distribution pattern(Pattern II),and a parabolic distribution pattern(Pattern III).Solutions were obtained for the average excess pore water pressures and the average degree of consolidation respectively.Then several special cases were discussed in detail based on the general solution obtained.Finally,comparisons were made,and the results show that the present solution is the most general rigorous solution in the literature,and it can be broken down into a number of previous solutions.The consolidation rate is accelerated with the increase in the value of the top to the bottom stress ratio.The consolidation rate calculated by the solution for Pattern I is less than that for Pattern II,which in turn is less than that for Pattern III. 展开更多
关键词 CONSOLIDATION composite foundation Stone column PERMEABILITY Ramp load Disturbance effect
原文传递
Composition control and temperature inferential control of dividing wall column based on model predictive control and PI strategies 被引量:4
15
作者 Jianxin Wang Na Yu +2 位作者 Mengqi Chen Lin Cong Lanyi Sun 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2018年第5期1087-1101,共15页
The dividing wall column (DWC) is considered as a major breakthrough in distillation technology and has good prospect of industrialization. Model predictive control (MPC) is an advanced control strategy that has a... The dividing wall column (DWC) is considered as a major breakthrough in distillation technology and has good prospect of industrialization. Model predictive control (MPC) is an advanced control strategy that has acquired extensive applications in various industries. In this study, MPC is applied to the process for separating ethanol, n-propanol, and n-butanol ternary mixture in a fully thermally coupled DWC. Both composition control and tem- perature inferent/al control are considered. The multiobjective genetic algor/thm function "gamult/obj" in Matlab is used for the weight tuning of MPC. Comparisons are made between the control performances of MPC and PI strategies. Simulation results show that although both MPC and PI schemes can stabilize the DWC in case of feed disturbances, MPC generally behaves better than the PI strategy for both composition control and tempera- ture inferential control, resulting in a more stable and superior performance with lower values of integral of squared error (ISE). 展开更多
关键词 Dividing wall column composition control Temperature inferential control PI strategy Model predictive control Genetic algorithm
在线阅读 下载PDF
On composite foundation with different vertical reinforcing elements under vertical loading:a physical model testing study 被引量:2
16
作者 Xian-zhi WANG Jun-jie ZHENG Jian-hua YIN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2010年第2期80-87,共8页
Aphysical model facility was designed, built, and setup for conducting model tests on a composite foundation in a soil ground. The model tests were carried out on a composite foundation with different combinations of ... Aphysical model facility was designed, built, and setup for conducting model tests on a composite foundation in a soil ground. The model tests were carried out on a composite foundation with different combinations of vertical reinforcement elements in the same soil ground. Via the analysis of the collected data the characteristics of the composite foundation with different reinforcing elements were obtained, including the characteristics of load-settlement curves, column stresses, stresses of the intercolumn soil, pile-soil stress ratio, and load-sharing ratios of columns and soil. Results from the model tests reveal the mechanism of a composite foundation with different reinforcing elements quantitatively. It is concluded that both a composite foundation with a combination of steel pipe pile and sand column and that with a combination of concrete pile and lime column have a higher bearing capacity than the composite foundation with only sand columns with the same conditions of soil ground and loading. A composite foundation with lime column and sand column embodies no much better performance than that with sand colunms only. 展开更多
关键词 Steel pipe pile Concrete pile Lime column Sand column composite foundation Model test Pile-soil stress ratio
原文传递
Testing of a Full-Scale Composite Floor Plate
17
作者 Dennis Lam Xianghe Dai Therese Sheehan 《Engineering》 SCIE EI 2019年第2期223-233,共11页
A full-scale composite floor plate was tested to investigate the flexural behavior and in-plane effects of the floor slab in a grillage of composite beams that reduces the tendency for longitudinal splitting of the co... A full-scale composite floor plate was tested to investigate the flexural behavior and in-plane effects of the floor slab in a grillage of composite beams that reduces the tendency for longitudinal splitting of the concrete slab along the line of the primary beams. This is important in cases where the steel decking is discontinuous when it is orientated parallel to the beams. In this case, it is important to demonstrate that the amount of transverse reinforcement required to transfer local forces from the shear connectors can be reduced relative to the requirements of Eurocode 4. The mechanism under study involved in-plane compression forces being developed in the slab due to the restraining action of the floor plate, which was held in position by the peripheral composite beams;while the secondary beams acted as transverse ties to resist the forces in the floor plate that would otherwise lead to splitting of the slab along the line of the primary beams. The tendency for cracking along the center line of the primary beam and at the peripheral beams was closely monitored. This is the first large floor plate test that has been carried out under laboratory conditions since the Cardington tests in the early 1990s, although those tests were not carried out to failure. This floor plate test was designed so that the longitudinal force transferred by the primary beams was relatively high (i.e., it was designed for full shear connection), but the transverse reinforcement was taken as the minimum of 0.2% of the concrete area. The test confirmed that the primary beams reached their plastic bending resistance despite the discontinuous decking and transverse reinforcement at the minimum percentage given in Eurocode 4. Based on this test, a reduction factor due to shear connectors at edge beams without U-bars is proposed. 展开更多
关键词 FLOOR plate test composite BEAMS Edge BEAMS EUROCODE 4 IN-PLANE effect column removal Robustness
在线阅读 下载PDF
Study on the Structure of Composite Material - Concrete - Steel Composite pier and foundation joint
18
作者 WANG Jiji HU Hao +1 位作者 CAO Suyun ZHANG Zhaomin 《外文科技期刊数据库(文摘版)工程技术》 2021年第6期476-480,共9页
The traditional reinforced concrete structure has the problems of structural performance degradation, as well as the low shear strength, poor ductility and other seismic performance, which leads to the failure or even... The traditional reinforced concrete structure has the problems of structural performance degradation, as well as the low shear strength, poor ductility and other seismic performance, which leads to the failure or even collapse of the bridge. Key joints and Bridges with high durability requirements should adopt pier forms with superior anti-corrosion performance and seismic performance. This paper presents a composite material-concrete-steel composite pier column, which is composed of glass fiber wound steel outer pipe, steel inner pipe and concrete filled between them. The composite column is expected to have superior corrosion resistance, ductility and seismic performance. In this paper, the joint construction and design method of the composite column and foundation are introduced to provide ideas for the design and application of the composite column. 展开更多
关键词 composite materials steel pipe composite column pier node
原文传递
Consolidation of high replacement ratio stone column-reinforced ground:Analytical solutions incorporating clogging effect
19
作者 Jinxin Sun Mengmeng Lu +1 位作者 Baolong Xu Jie Shan 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第8期3311-3326,共16页
The utilization of stone columns has emerged as a popular ground improvement strategy,whereas the drainage performance can be adversely hampered by clogging effect.Despite the ample progress of calculation methods for... The utilization of stone columns has emerged as a popular ground improvement strategy,whereas the drainage performance can be adversely hampered by clogging effect.Despite the ample progress of calculation methods for the consolidation of stone column-improved ground,theoretical investigations into the clogging effect have not been thoroughly explored.Furthermore,it is imperative to involve the column consolidation deformation to mitigate computational error on the consolidation of composite ground with high replacement ratios.In this context,an analytical model accounting for the initial clogging and coupled time and depth-dependent clogging of stone columns is established.Then,the resulting governing equations and analytical solutions are obtained under a new flow continuity relationship to incorporate column consolidation deformation.The accuracy and reliability of the proposed model are illustrated by degradation analysis and case studies with good agreements.Subsequently,the computed results of the current study are juxtaposed against the existing models,and an in-depth assessment of the impacts of several crucial parameters on the consolidation behavior is conducted.The results reveal that ignoring column consolidation deformation leads to an overestimate of the consolidation rate,with maximum error reaching up to 16%as the replacement ratio increases.Furthermore,the initial clogging also has a significant influence on the consolidation performance.Additionally,the increment of depth and time-clogging factors a and b will induce a noticeable retardation of the consolidation process,particularly in the later stage. 展开更多
关键词 CONSOLIDATION composite ground Stone column Clogging effect Ground improvement Analytical model
在线阅读 下载PDF
装配式PVA-ECC梁柱节点抗震性能研究 被引量:1
20
作者 李慧 杨丹 +1 位作者 郭瑞 余志祥 《建筑结构》 北大核心 2025年第4期38-43,共6页
节点核心区是装配式梁柱节点的薄弱部分,改善节点的连接是增强装配式结构核心区抗剪性能的关键问题。为提高装配式梁柱节点的抗震性能,采用聚乙烯醇-工程水泥基复合材料(PVA-ECC)代替梁柱节点核心区及相邻一定范围内梁端与柱端的普通混... 节点核心区是装配式梁柱节点的薄弱部分,改善节点的连接是增强装配式结构核心区抗剪性能的关键问题。为提高装配式梁柱节点的抗震性能,采用聚乙烯醇-工程水泥基复合材料(PVA-ECC)代替梁柱节点核心区及相邻一定范围内梁端与柱端的普通混凝土,并提出一种装配式梁柱节点的拆分构造。通过3个梁柱节点在循环荷载作用下的试验结果,比较了不同构造下梁柱节点的滞回性能、承载能力、耗能能力及刚度退化等抗震性能指标,验证了拆分构造方式的可行性。试验结果表明:现浇混凝土试件破坏最为严重,装配式PVA-ECC梁柱节点无混凝土剥落现象且裂缝宽度较小,并表现出多裂缝开裂现象;对比结果表明,纤维增强梁柱节点承载能力增强,可实现“等同现浇”,刚度退化减缓,耗能能力增强18%左右,表明提出的装配式PVA-ECC梁柱节点的拆分构造方式可行;通过对梁柱节点进行承载力验算,验证了装配式PVA-ECC梁柱节点的合理性,可进行实际应用。 展开更多
关键词 聚乙烯醇-工程水泥基复合材料 装配式梁柱节点 多裂缝开裂 拆分构造
在线阅读 下载PDF
上一页 1 2 92 下一页 到第
使用帮助 返回顶部