Stochastic Subspace Identification (SSI) is a novel time domain identification method, which directly uses operational response data to identify the system model by linear algebraic manipulations such as QR facto...Stochastic Subspace Identification (SSI) is a novel time domain identification method, which directly uses operational response data to identify the system model by linear algebraic manipulations such as QR factorization and Singular Value Decomposition (SVD). This paper deals with SSI and its applications for structural modal identification. The NASA mini mast model is used for simulations to illustrate how to select input parameters, and to demonstrate identification precision. A real building structure, the Heritage Court Tower (HCT) in Canada is analyzed. From the simulation and test researches, the conclusions can be made to instruct how to identify structural modal parameters using SSI method.展开更多
In this paper, the on-orbit identification of modal parameters for a spacecraft is investigated. Firstly, the coupled dynamic equation of the system is established with the Lagrange method and the stochastic state-spa...In this paper, the on-orbit identification of modal parameters for a spacecraft is investigated. Firstly, the coupled dynamic equation of the system is established with the Lagrange method and the stochastic state-space model of the system is obtained. Then, the covariance-driven stochastic subspace identification(SSI-COV) algorithm is adopted to identify the modal parameters of the system. In this algorithm, it just needs the covariance of output data of the system under ambient excitation to construct a Toeplitz matrix, thus the system matrices are obtained by the singular value decomposition on the Toeplitz matrix and the modal parameters of the system can be found from the system matrices. Finally,numerical simulations are carried out to demonstrate the validity of the SSI-COV algorithm. Simulation results indicate that the SSI-COV algorithm is effective in identifying the modal parameters of the spacecraft only using the output data of the system under ambient excitation.展开更多
Estimating low-frequency oscillation modes and the corresponding mode shapes based on ambient data from WAMS measurements has a promising prospect in power system analysis and control.Based on the stochastic subspace ...Estimating low-frequency oscillation modes and the corresponding mode shapes based on ambient data from WAMS measurements has a promising prospect in power system analysis and control.Based on the stochastic subspace method,this paper proposes a revised stochastic subspace method by introducing reference channels,which can estimate the modes and the mode shapes simultaneously with great computational efficiency.Meanwhile,the accuracy of the estimated results is not degraded.To discriminate the real modes from the spurious ones,the stabilization diagram is introduced.A novel algorithm is designed to deal with the stabilization diagram which can detect the real modes automatically.Tests conducted on the IEEE-118 system indicate that the proposed method has good performance in terms of both computational efficiency and accuracy,and has the potential of being used on-line.展开更多
In this paper, a data-driven stochastic subspace identification(SSI-DATA) technique is proposed as an advanced stochastic system identification(SSI) to extract the inter-area oscillation modes of a power system from w...In this paper, a data-driven stochastic subspace identification(SSI-DATA) technique is proposed as an advanced stochastic system identification(SSI) to extract the inter-area oscillation modes of a power system from wide-area measurements. For accurate and robust extraction of the modes’ parameters(frequency, damping and mode shape), SSI has already been verified as an effective identification algorithm for output-only modal analysis.The new feature of the proposed SSI-DATA applied to inter-area oscillation modal identification lies in its ability to select the eigenvalue automatically. The effectiveness of the proposed scheme has been fully studied and verified,first using transient stability data generated from the IEEE16-generator 5-area test system, and then using recorded data from an actual event using a Chinese wide-area measurement system(WAMS) in 2004. The results from the simulated and recorded measurements have validated the reliability and applicability of the SSI-DATA technique in power system low frequency oscillation analysis.展开更多
In the present contribution, operational modal analysis in conjunction with bees optimization algorithm are utilized to update the finite element model of a solar power plant structure. The physical parameters which r...In the present contribution, operational modal analysis in conjunction with bees optimization algorithm are utilized to update the finite element model of a solar power plant structure. The physical parameters which required to be updated are uncertain parameters including geometry, material properties and boundary conditions of the aforementioned structure. To determine these uncertain parameters, local and global sensitivity analyses are performed to increase the solution accuracy. An objective function is determined using the sum of the squared errors between the natural frequencies calculated by finite element method and operational modal analysis, which is optimized using bees optimization algorithm. The natural frequencies of the solar power plant structure are estimated by multi-setup stochastic subspace identification method which is considered as a strong and efficient method in operational modal analysis. The proposed algorithm is efficiently implemented on the solar power plant structure located in Shahid Chamran university of Ahvaz, Iran, to update parameters of its finite element model. Moreover, computed natural frequencies by numerical method are compared with those of the operational modal analysis. The results indicate that, bees optimization algorithm leads accurate results with fast convergence.展开更多
The occurrence of low-frequency electromechanical oscillations is a major problem in the effective operation of power systems. The scrutiny of these oscillations provides substantial information about power system sta...The occurrence of low-frequency electromechanical oscillations is a major problem in the effective operation of power systems. The scrutiny of these oscillations provides substantial information about power system stability and security. In this paper, a new method is introduced based on a combination of synchrosqueezed wavelet transform and the stochastic subspace identification (SSI) algorithm to investigate the low-frequency electromechanical oscillations of large-scale power systems. Then, the estimated modes of the power system are used for the design of the power system stabilizer and the flexible alternating current transmission system (FACTS) device. In this optimization problem, the control parameters are set using a hybrid approach composed of the Prony and residual methods and the modified fruit fly optimization algorithm. The proposed mode estimation method and the controller design are simulated in MATLAB using two test case systems, namely IEEE 2-area 4-generator and New England-New York 68-bus 16-generator systems. The simulation results demonstrate the high performance of the proposed method in estimation of local and inter-area modes, and indicate the improvements in oscillation damping and power system stability.展开更多
Modal analysis,which provides modal parameters including frequencies,damping ratios,and mode shapes,is essential for assessing structural safety in structural health monitoring.Automated operational modal analysis(AOM...Modal analysis,which provides modal parameters including frequencies,damping ratios,and mode shapes,is essential for assessing structural safety in structural health monitoring.Automated operational modal analysis(AOMA)offers a promising alternative to traditional methods that depend heavily on human intervention and engineering judgment.However,estimating structural dynamic properties and managing spurious modes remain challenging due to uncertainties in practical application conditions.To address this issue,we propose an automated modal identification approach comprising three key aspects:(1)identification of modal parameters using covariance-driven stochastic subspace identification;(2)automated interpretation of the stabilization diagram;(3)an improved self-adaptive algorithm for grouping physical modes based on ordering points to identify the clustering structure(OPTICS)combined with k-nearest neighbors(KNN).The proposed approach can play a crucial role in enabling real-time structural health monitoring without human intervention.A simulated 10-story shear frame was used to verify the methodology.Identification results from a cable-stayed bridge demonstrate the practicality of the proposed method for conducting AOMA in engineering practice.The proposed approach can automatically identify modal parameters with high accuracy,making it suitable for a real-time structural health monitoring framework.展开更多
Traditional modal parameter identifi cation methods have many disadvantages,especially when used for processing nonlinear and non-stationary signals.In addition,they are usually not able to accurately identify the dam...Traditional modal parameter identifi cation methods have many disadvantages,especially when used for processing nonlinear and non-stationary signals.In addition,they are usually not able to accurately identify the damping ratio and damage.In this study,methods based on the Hilbert-Huang transform(HHT) are investigated for structural modal parameter identifi cation and damage diagnosis.First,mirror extension and prediction via a radial basis function(RBF) neural network are used to restrain the troublesome end-effect issue in empirical mode decomposition(EMD),which is a crucial part of HHT.Then,the approaches based on HHT combined with other techniques,such as the random decrement technique(RDT),natural excitation technique(NExT) and stochastic subspace identifi cation(SSI),are proposed to identify modal parameters of structures.Furthermore,a damage diagnosis method based on the HHT is also proposed.Time-varying instantaneous frequency and instantaneous energy are used to identify the damage evolution of the structure.The relative amplitude of the Hilbert marginal spectrum is used to identify the damage location of the structure.Finally,acceleration records at gauge points from shaking table testing of a 12-story reinforced concrete frame model are taken to validate the proposed approaches.The results show that the proposed approaches based on HHT for modal parameter identifi cation and damage diagnosis are reliable and practical.展开更多
Modal parameters, including fundamental frequencies, damping ratios, and mode shapes, could be used to evaluate the health condition of structures. Automatic modal parameter identification, which plays an essential ro...Modal parameters, including fundamental frequencies, damping ratios, and mode shapes, could be used to evaluate the health condition of structures. Automatic modal parameter identification, which plays an essential role in realtime structural health monitoring, has become a popular topic in recent years. In this study, an automatic modal parameter identification procedure for high arch dams is proposed. The proposed procedure is implemented by combining the densitybased spatial clustering of applications with noise(DBSCAN) algorithm and the stochastic subspace identification(SSI). The 210-m-high Dagangshan Dam is investigated as an example to verify the feasibility of the procedure. The results show that the DBSCAN algorithm is robust enough to interpret the stabilization diagram from SSI and may avoid outline modes. This leads to the proposed procedure obtaining a better performance than the partitioned clustering and hierarchical clustering algorithms. In addition, the errors of the identified frequencies of the arch dam are within 4%, and the identified mode shapes are in agreement with those obtained from the finite element model, which implies that the proposed procedure is accurate enough to use in modal parameter identification. The procedure is feasible for online modal parameter identification and modal tracking of arch dams.展开更多
We conducted a long-term monitoring experiment on the Lutuanxilu Bridge located in Changping District of Beijing, employing our recently developed real-time bridge monitoring system based on the Guralp CMG-6TD broadba...We conducted a long-term monitoring experiment on the Lutuanxilu Bridge located in Changping District of Beijing, employing our recently developed real-time bridge monitoring system based on the Guralp CMG-6TD broadband seismometer. We identified the modal parameters with the stochastic subspace identification( SSI) algorithm,and continuously monitored the temporal velocity variation with coda wave interferometry.The results show that:( 1) the highly sensitive Guralp CMG-6TD broadband seismometer,which records the three-component vibration signal within broad frequency range,is well suited for long-term bridge health monitoring.( 2) With the continuous vibration signal from ambient excitation,the stochastic subspace algorithm can robustly identify the low-order modal parameters and the coda wave interferometry can accurately monitor the tiny velocity variation.( 3) The elastic modulus of bridge materials changes significantly associated with varying temperature,leading to diurnal velocity variation with amplitude of approximately 1%. The velocity variation shows strong negative correlation with temperature fluctuation. Meanwhile,the modal frequencies remain quite stable,suggesting that the velocity variation may be a more sensitive quantitative damage index.( 4) While the modal frequencies reflect the integrated health status of the bridge,the velocity variation can be utilized to monitor the local elastic modulus. Therefore,it is crucial for bridge health monitoring to continuously monitor the two key damage indexes under ambient excitation.展开更多
The possibility of determining the integrity of a real structure subjected to non-invasive and non-destructive monitoring,such as that carried out by a series of accelerometers placed on the structure,is certainly a g...The possibility of determining the integrity of a real structure subjected to non-invasive and non-destructive monitoring,such as that carried out by a series of accelerometers placed on the structure,is certainly a goal of extreme and current interest.In the present work,the results obtained from the processing of experimental data of a real structure are shown.The analyzed structure is a lattice structure approximately 9 m high,monitored with 18 uniaxial accelerometers positioned in pairs on 9 different levels.The data used refer to continuous monitoring that lasted for a total of 1 year,during which minor damage was caused to the structure by alternatively removing some bracings and repositioning them in the structure.Two methodologies detecting damage based on decomposition techniques of the acquired data were used and tested,as well as a methodology combining the two techniques.The results obtained are extremely interesting,as all the minor damage caused to the structure was identified by the processing methods used,based solely on the monitored data and without any knowledge of the real structure being analyzed.The results use 15 acquisitions in environmental conditions lasting 10 min each,a reasonable amount of time to get immediate feedback on possible damage to the structure.展开更多
文摘Stochastic Subspace Identification (SSI) is a novel time domain identification method, which directly uses operational response data to identify the system model by linear algebraic manipulations such as QR factorization and Singular Value Decomposition (SVD). This paper deals with SSI and its applications for structural modal identification. The NASA mini mast model is used for simulations to illustrate how to select input parameters, and to demonstrate identification precision. A real building structure, the Heritage Court Tower (HCT) in Canada is analyzed. From the simulation and test researches, the conclusions can be made to instruct how to identify structural modal parameters using SSI method.
基金supported by the National Natural Science Foundation of China(Grants 11132001,11272202,11472171)the Key Scientific Project of Shanghai Municipal Education Commission(Grant 14ZZ021)+1 种基金the Natural Science Foundation of Shanghai(Grant 14ZR1421000)the Special Fund for Talent Development of Minhang District of Shanghai
文摘In this paper, the on-orbit identification of modal parameters for a spacecraft is investigated. Firstly, the coupled dynamic equation of the system is established with the Lagrange method and the stochastic state-space model of the system is obtained. Then, the covariance-driven stochastic subspace identification(SSI-COV) algorithm is adopted to identify the modal parameters of the system. In this algorithm, it just needs the covariance of output data of the system under ambient excitation to construct a Toeplitz matrix, thus the system matrices are obtained by the singular value decomposition on the Toeplitz matrix and the modal parameters of the system can be found from the system matrices. Finally,numerical simulations are carried out to demonstrate the validity of the SSI-COV algorithm. Simulation results indicate that the SSI-COV algorithm is effective in identifying the modal parameters of the spacecraft only using the output data of the system under ambient excitation.
基金supported by the National Natural Science Foundation of China (Grant No. 51177079)the Program for Century Excellent Talents in University of China (Grant No. NCET-028-0317)
文摘Estimating low-frequency oscillation modes and the corresponding mode shapes based on ambient data from WAMS measurements has a promising prospect in power system analysis and control.Based on the stochastic subspace method,this paper proposes a revised stochastic subspace method by introducing reference channels,which can estimate the modes and the mode shapes simultaneously with great computational efficiency.Meanwhile,the accuracy of the estimated results is not degraded.To discriminate the real modes from the spurious ones,the stabilization diagram is introduced.A novel algorithm is designed to deal with the stabilization diagram which can detect the real modes automatically.Tests conducted on the IEEE-118 system indicate that the proposed method has good performance in terms of both computational efficiency and accuracy,and has the potential of being used on-line.
基金supported by the National Natural Science Foundation of China(No.51507028)the Hong Kong Polytechnic University under Project G-UA3Z
文摘In this paper, a data-driven stochastic subspace identification(SSI-DATA) technique is proposed as an advanced stochastic system identification(SSI) to extract the inter-area oscillation modes of a power system from wide-area measurements. For accurate and robust extraction of the modes’ parameters(frequency, damping and mode shape), SSI has already been verified as an effective identification algorithm for output-only modal analysis.The new feature of the proposed SSI-DATA applied to inter-area oscillation modal identification lies in its ability to select the eigenvalue automatically. The effectiveness of the proposed scheme has been fully studied and verified,first using transient stability data generated from the IEEE16-generator 5-area test system, and then using recorded data from an actual event using a Chinese wide-area measurement system(WAMS) in 2004. The results from the simulated and recorded measurements have validated the reliability and applicability of the SSI-DATA technique in power system low frequency oscillation analysis.
文摘In the present contribution, operational modal analysis in conjunction with bees optimization algorithm are utilized to update the finite element model of a solar power plant structure. The physical parameters which required to be updated are uncertain parameters including geometry, material properties and boundary conditions of the aforementioned structure. To determine these uncertain parameters, local and global sensitivity analyses are performed to increase the solution accuracy. An objective function is determined using the sum of the squared errors between the natural frequencies calculated by finite element method and operational modal analysis, which is optimized using bees optimization algorithm. The natural frequencies of the solar power plant structure are estimated by multi-setup stochastic subspace identification method which is considered as a strong and efficient method in operational modal analysis. The proposed algorithm is efficiently implemented on the solar power plant structure located in Shahid Chamran university of Ahvaz, Iran, to update parameters of its finite element model. Moreover, computed natural frequencies by numerical method are compared with those of the operational modal analysis. The results indicate that, bees optimization algorithm leads accurate results with fast convergence.
文摘The occurrence of low-frequency electromechanical oscillations is a major problem in the effective operation of power systems. The scrutiny of these oscillations provides substantial information about power system stability and security. In this paper, a new method is introduced based on a combination of synchrosqueezed wavelet transform and the stochastic subspace identification (SSI) algorithm to investigate the low-frequency electromechanical oscillations of large-scale power systems. Then, the estimated modes of the power system are used for the design of the power system stabilizer and the flexible alternating current transmission system (FACTS) device. In this optimization problem, the control parameters are set using a hybrid approach composed of the Prony and residual methods and the modified fruit fly optimization algorithm. The proposed mode estimation method and the controller design are simulated in MATLAB using two test case systems, namely IEEE 2-area 4-generator and New England-New York 68-bus 16-generator systems. The simulation results demonstrate the high performance of the proposed method in estimation of local and inter-area modes, and indicate the improvements in oscillation damping and power system stability.
基金supported by the National Natural Science Foundation of China(No.52408200)the Natural Science Foundation of Jiangsu Province(No.BK20240996)+1 种基金China,the Suzhou Science and Technology Plan(Basic Research)Project(No.SJC2023002)China,and the Natural Science Research Projects of Colleges and Universities in Jiangsu Province(No.24KJB560022),China.
文摘Modal analysis,which provides modal parameters including frequencies,damping ratios,and mode shapes,is essential for assessing structural safety in structural health monitoring.Automated operational modal analysis(AOMA)offers a promising alternative to traditional methods that depend heavily on human intervention and engineering judgment.However,estimating structural dynamic properties and managing spurious modes remain challenging due to uncertainties in practical application conditions.To address this issue,we propose an automated modal identification approach comprising three key aspects:(1)identification of modal parameters using covariance-driven stochastic subspace identification;(2)automated interpretation of the stabilization diagram;(3)an improved self-adaptive algorithm for grouping physical modes based on ordering points to identify the clustering structure(OPTICS)combined with k-nearest neighbors(KNN).The proposed approach can play a crucial role in enabling real-time structural health monitoring without human intervention.A simulated 10-story shear frame was used to verify the methodology.Identification results from a cable-stayed bridge demonstrate the practicality of the proposed method for conducting AOMA in engineering practice.The proposed approach can automatically identify modal parameters with high accuracy,making it suitable for a real-time structural health monitoring framework.
基金Gansu Science and Technology Key Project under Grant No.2GS057-A52-008
文摘Traditional modal parameter identifi cation methods have many disadvantages,especially when used for processing nonlinear and non-stationary signals.In addition,they are usually not able to accurately identify the damping ratio and damage.In this study,methods based on the Hilbert-Huang transform(HHT) are investigated for structural modal parameter identifi cation and damage diagnosis.First,mirror extension and prediction via a radial basis function(RBF) neural network are used to restrain the troublesome end-effect issue in empirical mode decomposition(EMD),which is a crucial part of HHT.Then,the approaches based on HHT combined with other techniques,such as the random decrement technique(RDT),natural excitation technique(NExT) and stochastic subspace identifi cation(SSI),are proposed to identify modal parameters of structures.Furthermore,a damage diagnosis method based on the HHT is also proposed.Time-varying instantaneous frequency and instantaneous energy are used to identify the damage evolution of the structure.The relative amplitude of the Hilbert marginal spectrum is used to identify the damage location of the structure.Finally,acceleration records at gauge points from shaking table testing of a 12-story reinforced concrete frame model are taken to validate the proposed approaches.The results show that the proposed approaches based on HHT for modal parameter identifi cation and damage diagnosis are reliable and practical.
基金National Natural Science Foundation of China under Grant Nos. 51725901 and 51639006。
文摘Modal parameters, including fundamental frequencies, damping ratios, and mode shapes, could be used to evaluate the health condition of structures. Automatic modal parameter identification, which plays an essential role in realtime structural health monitoring, has become a popular topic in recent years. In this study, an automatic modal parameter identification procedure for high arch dams is proposed. The proposed procedure is implemented by combining the densitybased spatial clustering of applications with noise(DBSCAN) algorithm and the stochastic subspace identification(SSI). The 210-m-high Dagangshan Dam is investigated as an example to verify the feasibility of the procedure. The results show that the DBSCAN algorithm is robust enough to interpret the stabilization diagram from SSI and may avoid outline modes. This leads to the proposed procedure obtaining a better performance than the partitioned clustering and hierarchical clustering algorithms. In addition, the errors of the identified frequencies of the arch dam are within 4%, and the identified mode shapes are in agreement with those obtained from the finite element model, which implies that the proposed procedure is accurate enough to use in modal parameter identification. The procedure is feasible for online modal parameter identification and modal tracking of arch dams.
基金sponsored by "Microseismic response characteristic of typical bridges in Beijing under environmental excitations"( ZX20130335)the scientific research foundation of China University of Petroleum-Beijing ( 2462014YJRC045)
文摘We conducted a long-term monitoring experiment on the Lutuanxilu Bridge located in Changping District of Beijing, employing our recently developed real-time bridge monitoring system based on the Guralp CMG-6TD broadband seismometer. We identified the modal parameters with the stochastic subspace identification( SSI) algorithm,and continuously monitored the temporal velocity variation with coda wave interferometry.The results show that:( 1) the highly sensitive Guralp CMG-6TD broadband seismometer,which records the three-component vibration signal within broad frequency range,is well suited for long-term bridge health monitoring.( 2) With the continuous vibration signal from ambient excitation,the stochastic subspace algorithm can robustly identify the low-order modal parameters and the coda wave interferometry can accurately monitor the tiny velocity variation.( 3) The elastic modulus of bridge materials changes significantly associated with varying temperature,leading to diurnal velocity variation with amplitude of approximately 1%. The velocity variation shows strong negative correlation with temperature fluctuation. Meanwhile,the modal frequencies remain quite stable,suggesting that the velocity variation may be a more sensitive quantitative damage index.( 4) While the modal frequencies reflect the integrated health status of the bridge,the velocity variation can be utilized to monitor the local elastic modulus. Therefore,it is crucial for bridge health monitoring to continuously monitor the two key damage indexes under ambient excitation.
基金The author N.I.Giannoccaro received funds from the Department of Innovation Engineering,University of Salento,for acquiring the tool Structural Health Monitoring.
文摘The possibility of determining the integrity of a real structure subjected to non-invasive and non-destructive monitoring,such as that carried out by a series of accelerometers placed on the structure,is certainly a goal of extreme and current interest.In the present work,the results obtained from the processing of experimental data of a real structure are shown.The analyzed structure is a lattice structure approximately 9 m high,monitored with 18 uniaxial accelerometers positioned in pairs on 9 different levels.The data used refer to continuous monitoring that lasted for a total of 1 year,during which minor damage was caused to the structure by alternatively removing some bracings and repositioning them in the structure.Two methodologies detecting damage based on decomposition techniques of the acquired data were used and tested,as well as a methodology combining the two techniques.The results obtained are extremely interesting,as all the minor damage caused to the structure was identified by the processing methods used,based solely on the monitored data and without any knowledge of the real structure being analyzed.The results use 15 acquisitions in environmental conditions lasting 10 min each,a reasonable amount of time to get immediate feedback on possible damage to the structure.