Two biological nitrogen removal processes are compared in the aspect of nitrogen removal, process operation and energy saving. Results show that when the returned sludge ratio is 50% of the inflow rate, the step-feedi...Two biological nitrogen removal processes are compared in the aspect of nitrogen removal, process operation and energy saving. Results show that when the returned sludge ratio is 50% of the inflow rate, the step-feeding process achieves over 80% total nitrogen (TN) removal efficiency, but the TN removal efficiency of the A/O process is only 40%. Moreover, filamentous sludge bulking can be well restrained in the step-feeding process. Given the conditions of a returned sludge ratio of 100% and a nitrifying liquor recycle ratio of 200%, the TN removal efficiency is 78.32% in the A/O process, but the sludge volume index (SVI) value increases to 143 mL/g. In the step-feeding process, the SVI is only 94.4 mL/g when the TN removal efficiency reaches 81. 1%. The step-feeding process has distinct advantages over the A/O process in the aspects of practicability, nitrogen removal and operating stability.展开更多
Two full-scale systems operated in parallel, a conventional A2/O system consisting of anaerobic, anoxic and oxic compartments in succession and an inverted system consisting of anoxic, anaerobic and oxic compartments ...Two full-scale systems operated in parallel, a conventional A2/O system consisting of anaerobic, anoxic and oxic compartments in succession and an inverted system consisting of anoxic, anaerobic and oxic compartments without internal recycle, were compared in terms of their phosphorus removal performance, with an emphasis on phosphate (P) release behaviors, using both operational data and simulation results. The inverted system exhibited better long-term phosphorus removal performance (0.2 ± 0.3 vs. 0.7 ±0.7 mg/L), which should be attributed to the higher P release rate (0.79 vs. 0.60 kg P/(kg MLSS.day)) in the non-aerated compartments. The P release occurred in both the anoxic and anaerobic compartments of the inverted system, resulting in more efficient P release. Although the abundances of the 'Candidatus Accumulibacter phosphatis' population in the two systems were quite similar ((19.1 + 3.27)% and (18.4 + 4.15)% of the total microbe (DAPI stained particles) population in the inverted and conventional systems, respectively, by fluorescence in situ hybridization (FISH)), the high-concentration DAPI staining results show that the abundances of the whole polyphosphate accumulating organisms (PAOs) in the aerobic ends were quite different (the average ratios of the poly-P granules to total microbes (DAPI stained particles) were (45 ±4.18)% and (35 ± 5.39)%, respectively). Both the operational data and simulation results showed that the inverted system retained more abundant PAO populations due to its special configuration, which permitted efficient P release in the non-aerated compartment and better P removal,展开更多
In order to improve nitrogen removal in anoxic/oxic(A/O) process effectively for treating domestic wastewaters, the influence factors, DO(dissolved oxygen), nitrate recirculation, sludge recycle, SRT(solids residence ...In order to improve nitrogen removal in anoxic/oxic(A/O) process effectively for treating domestic wastewaters, the influence factors, DO(dissolved oxygen), nitrate recirculation, sludge recycle, SRT(solids residence time), influent COD/TN and HRT(hydraulic retention time) were studied. Results indicated that it was possible to increase nitrogen removal by using corresponding control strategies, such as, adjusting the DO set point according to effluent ammonia concentration; manipulating nitrate recirculation flow according to nitrate concentration at the end of anoxic zone. Based on the experiments results, a knowledge-based approach for supervision of the nitrogen removal problems was considered, and decision trees for diagnosing nitrification and denitrification problems were built and successfully applied to A/O process.展开更多
This study evaluated the removal of multiple pollutants,i.e.,polybrominated diphenyl ethers(PBDEs),novel halogenated flame retardants(HFRs),sulfonamide antibiotics(SAs),and heavy metals(HMs),by a fullscale reversed A^...This study evaluated the removal of multiple pollutants,i.e.,polybrominated diphenyl ethers(PBDEs),novel halogenated flame retardants(HFRs),sulfonamide antibiotics(SAs),and heavy metals(HMs),by a fullscale reversed A^(2)/O process in a sewage treatment plant(STP)in Guangzhou,China.The reversed A^(2)/O process demonstrated high removal efficiencies(REs)for total PBDEs(60.5%±4.3%),novel HFRs(98.4%±2.8%)and HMs(70.1%±1.2%),and a relatively low RE for SAs(25.0%±2.3%).BDE 209,the dominant PBDE congener,showed a high residual concentration(13.41±5.18 ng/L)in the suspended particulate matter(SPM)of treated effluents.So me novel HFRs,dechlorane plus(DP)and decabromodiphe nyl ethane(DBDPE),were detected in the SPM of the raw sewage(7.50±4.14 ng/L and 11.52±11.65 ng/L,respectively).The removal ofSAs was mainly through biodegradation in the activated sludge bioreactors(ASBs).Ofthe HMs,Mn and Ni exhibited the lowest REs(47.5%±2.2%and 35.0%±2.6%,respectively),while Cr and Cu showed the highest removal(REs>80%).In terms of treatment units in the reversed A^(2)/O process,ASBs showed the highest RE(27.8%)for the multiple pollutants.The information can aid in our understanding of removal properties of STPs on various pollutants and evaluating the ecological/health risks of STPs as point pollutant sources.展开更多
Full scale experimental study on nitrogen removal for low-carbon wastewater was conducted in reversed A2/O process in Jiguanshi waste water treatment plant in Chongqing,in order to aid the operation and maintenance of...Full scale experimental study on nitrogen removal for low-carbon wastewater was conducted in reversed A2/O process in Jiguanshi waste water treatment plant in Chongqing,in order to aid the operation and maintenance of similar WWTP. When the proposed measures,such as using 0.1% (volume fraction of wastewater) landfill leachate,shortening HRT by 2/3 in the primary sedimentation tank and controlling DO at 0.5 mg/L in the 3rd section of aerobic zone,are applied,15% of the carbon source can be complemented,the favorable property of activated sludge is achieved,and the nitrogen removal effect is significantly improved. The effluent NH3-N is 2 mg/L and the removal rate is 90%. The effluent TN is 17 mg/L and the removal rate is 54%. The up-to-standard discharge of the effluent is achieved. And after the optimization,the unit electricity consumption also reaches 0.21 kW/h and saves 20%.展开更多
In this paper three controllers for A/O process are developed, including a DO cascade controller, an external carbon flow rate controller and an internal recycling flow rate controller. The objective of the different ...In this paper three controllers for A/O process are developed, including a DO cascade controller, an external carbon flow rate controller and an internal recycling flow rate controller. The objective of the different controllers is to control the nitrate and ammonia concentration. Simulation study demonstrated that these controllers could efficiently control nitrogen removal and meet stricter effluent quality standards at a minimum cost.展开更多
Erratum to:International Journal of Minerals,Metallurgy and Materials Volume 31,Number 1,January 2024,Page 186 https://doi.org/10.1007/s12613-023-2744-0 The original version of this article unfortunately contained thr...Erratum to:International Journal of Minerals,Metallurgy and Materials Volume 31,Number 1,January 2024,Page 186 https://doi.org/10.1007/s12613-023-2744-0 The original version of this article unfortunately contained three mistakes.The presentation of Fig.8 in original version was incorrect.The correct version is given below.展开更多
基金The Project of Scientific Research Base and Scientific Innovation Platform of Beijing Municipal Education Commission (No.PXM2008-014204-050843)the Project of Beijing Science and Technology Committee (No.D07050601500000)+1 种基金the Knowledge Innovation Program of the Chinese Academy of Sciences (No.RCEES-QN-200706)the Special Funds for Young Scholars of RCEES,CAS.
文摘Two biological nitrogen removal processes are compared in the aspect of nitrogen removal, process operation and energy saving. Results show that when the returned sludge ratio is 50% of the inflow rate, the step-feeding process achieves over 80% total nitrogen (TN) removal efficiency, but the TN removal efficiency of the A/O process is only 40%. Moreover, filamentous sludge bulking can be well restrained in the step-feeding process. Given the conditions of a returned sludge ratio of 100% and a nitrifying liquor recycle ratio of 200%, the TN removal efficiency is 78.32% in the A/O process, but the sludge volume index (SVI) value increases to 143 mL/g. In the step-feeding process, the SVI is only 94.4 mL/g when the TN removal efficiency reaches 81. 1%. The step-feeding process has distinct advantages over the A/O process in the aspects of practicability, nitrogen removal and operating stability.
基金supported by the National Natural Science Foundation of China (No. 20921140094)the Knowledge Innovation Project of Chinese Academy of Sciences(No. KSCX2-YW-G-054)
文摘Two full-scale systems operated in parallel, a conventional A2/O system consisting of anaerobic, anoxic and oxic compartments in succession and an inverted system consisting of anoxic, anaerobic and oxic compartments without internal recycle, were compared in terms of their phosphorus removal performance, with an emphasis on phosphate (P) release behaviors, using both operational data and simulation results. The inverted system exhibited better long-term phosphorus removal performance (0.2 ± 0.3 vs. 0.7 ±0.7 mg/L), which should be attributed to the higher P release rate (0.79 vs. 0.60 kg P/(kg MLSS.day)) in the non-aerated compartments. The P release occurred in both the anoxic and anaerobic compartments of the inverted system, resulting in more efficient P release. Although the abundances of the 'Candidatus Accumulibacter phosphatis' population in the two systems were quite similar ((19.1 + 3.27)% and (18.4 + 4.15)% of the total microbe (DAPI stained particles) population in the inverted and conventional systems, respectively, by fluorescence in situ hybridization (FISH)), the high-concentration DAPI staining results show that the abundances of the whole polyphosphate accumulating organisms (PAOs) in the aerobic ends were quite different (the average ratios of the poly-P granules to total microbes (DAPI stained particles) were (45 ±4.18)% and (35 ± 5.39)%, respectively). Both the operational data and simulation results showed that the inverted system retained more abundant PAO populations due to its special configuration, which permitted efficient P release in the non-aerated compartment and better P removal,
文摘In order to improve nitrogen removal in anoxic/oxic(A/O) process effectively for treating domestic wastewaters, the influence factors, DO(dissolved oxygen), nitrate recirculation, sludge recycle, SRT(solids residence time), influent COD/TN and HRT(hydraulic retention time) were studied. Results indicated that it was possible to increase nitrogen removal by using corresponding control strategies, such as, adjusting the DO set point according to effluent ammonia concentration; manipulating nitrate recirculation flow according to nitrate concentration at the end of anoxic zone. Based on the experiments results, a knowledge-based approach for supervision of the nitrogen removal problems was considered, and decision trees for diagnosing nitrification and denitrification problems were built and successfully applied to A/O process.
基金the National Natural Science Foundation of China(No.91851110)Guangzhou University’s 2017 Training Program for Young Top-Notch Personnels(No.BJ201713)+1 种基金Scientific Research Project of Guangzhou University(No.YK2020017)Guizhou Provincial Department of Education Youth Science and Technology Talents Growth Project(No.KY[2017]300)。
文摘This study evaluated the removal of multiple pollutants,i.e.,polybrominated diphenyl ethers(PBDEs),novel halogenated flame retardants(HFRs),sulfonamide antibiotics(SAs),and heavy metals(HMs),by a fullscale reversed A^(2)/O process in a sewage treatment plant(STP)in Guangzhou,China.The reversed A^(2)/O process demonstrated high removal efficiencies(REs)for total PBDEs(60.5%±4.3%),novel HFRs(98.4%±2.8%)and HMs(70.1%±1.2%),and a relatively low RE for SAs(25.0%±2.3%).BDE 209,the dominant PBDE congener,showed a high residual concentration(13.41±5.18 ng/L)in the suspended particulate matter(SPM)of treated effluents.So me novel HFRs,dechlorane plus(DP)and decabromodiphe nyl ethane(DBDPE),were detected in the SPM of the raw sewage(7.50±4.14 ng/L and 11.52±11.65 ng/L,respectively).The removal ofSAs was mainly through biodegradation in the activated sludge bioreactors(ASBs).Ofthe HMs,Mn and Ni exhibited the lowest REs(47.5%±2.2%and 35.0%±2.6%,respectively),while Cr and Cu showed the highest removal(REs>80%).In terms of treatment units in the reversed A^(2)/O process,ASBs showed the highest RE(27.8%)for the multiple pollutants.The information can aid in our understanding of removal properties of STPs on various pollutants and evaluating the ecological/health risks of STPs as point pollutant sources.
基金Project (2009ZX07315-002-01) supported by Water Pollution Control and Management of Major Special Science and Technology
文摘Full scale experimental study on nitrogen removal for low-carbon wastewater was conducted in reversed A2/O process in Jiguanshi waste water treatment plant in Chongqing,in order to aid the operation and maintenance of similar WWTP. When the proposed measures,such as using 0.1% (volume fraction of wastewater) landfill leachate,shortening HRT by 2/3 in the primary sedimentation tank and controlling DO at 0.5 mg/L in the 3rd section of aerobic zone,are applied,15% of the carbon source can be complemented,the favorable property of activated sludge is achieved,and the nitrogen removal effect is significantly improved. The effluent NH3-N is 2 mg/L and the removal rate is 90%. The effluent TN is 17 mg/L and the removal rate is 54%. The up-to-standard discharge of the effluent is achieved. And after the optimization,the unit electricity consumption also reaches 0.21 kW/h and saves 20%.
基金This work was supported by"863"Program of China (2004AA601020),The Project of Beijing Science and technology Committee(H020620010120) and the project of Beijing city key laboratory
文摘In this paper three controllers for A/O process are developed, including a DO cascade controller, an external carbon flow rate controller and an internal recycling flow rate controller. The objective of the different controllers is to control the nitrate and ammonia concentration. Simulation study demonstrated that these controllers could efficiently control nitrogen removal and meet stricter effluent quality standards at a minimum cost.
文摘Erratum to:International Journal of Minerals,Metallurgy and Materials Volume 31,Number 1,January 2024,Page 186 https://doi.org/10.1007/s12613-023-2744-0 The original version of this article unfortunately contained three mistakes.The presentation of Fig.8 in original version was incorrect.The correct version is given below.