Seismicity resulting from the near-or in-field fault activation significantly affects the stability of large-scale underground caverns that are operating under high-stress conditions.A comprehensive scientific assessm...Seismicity resulting from the near-or in-field fault activation significantly affects the stability of large-scale underground caverns that are operating under high-stress conditions.A comprehensive scientific assessment of the operational safety of such caverns requires an in-depth understanding of the response characteristics of the rock mass subjected to dynamic disturbances.To address this issue,we conducted true triaxial modeling tests and dynamic numerical simulations on large underground caverns to investigate the impact of static stress levels,dynamic load parameters,and input directions on the response characteristics of the surrounding rock mass.The findings reveal that:(1)When subjected to identical incident stress waves and static loads,the surrounding rock mass exhibits the greatest stress response during horizontal incidence.When the incident direction is fixed,the mechanical response is more pronounced at the cavern wall parallel to the direction of dynamic loading.(2)A high initial static stress level specifically enhances the impact of dynamic loading.(3)The response of the surrounding rock mass is directly linked to the amplitude of the incident stress wave.High amplitude results in tensile damage in regions experiencing tensile stress concentration under static loading and shear damage in regions experiencing compressive stress concentration.These results have significant implications for the evaluation and prevention of dynamic disasters in the surrounding rock of underground caverns experiencing dynamic disturbances.展开更多
This paper mainly focuses on the establishment of an effective static estimation method for the extreme wind-induced force for clips between purlins and metal panels of the standing-seam metal roofing system(hereinaft...This paper mainly focuses on the establishment of an effective static estimation method for the extreme wind-induced force for clips between purlins and metal panels of the standing-seam metal roofing system(hereinafter referred to as SMRS)of typical double-slope light-weight steel portal frame structure considering dynamic characteristics of wind and structure.First,simultaneous pressure measurement with rigid gable roof models was conducted mainly considering the length-span ratio in the boundary layer wind tunnel of Tokyo Polytechnic University,Japan.Then,finite element modeling for SMRS according to the wind load path in the roofing system was carried out to check the actual wind load of the clips based on the traditional calculation method provided in design codes,and the spatial correlation of fluctuating wind pressure on the roof surface,as well as the dynamic effect of the roof structure itself,had been considered.According to the related Chinese,American,and Japanese codes,a magnification coefficient based on the traditional method of static wind-induced force for the clips was calculated and compared.Finally,a simplified estimation method of effective wind-induced force for the clips in typical zones on the roof surface considering dynamic characteristics was proposed.展开更多
Chromium is a harmful contaminant showing mutagenicity and carcinogenicity.Therefore,detection of chromium requires the development of low-cost and high-sensitivity sensors.Herein,blue-fluorescent carbon quantum dots ...Chromium is a harmful contaminant showing mutagenicity and carcinogenicity.Therefore,detection of chromium requires the development of low-cost and high-sensitivity sensors.Herein,blue-fluorescent carbon quantum dots were synthesized by one-step hydrothermal method from alkali-soluble Poria cocos polysaccharide,which is green source,cheap and easy to obtain,and has no pharmacological activity due to low water solubility.These carbon quantum dots exhibit good fluorescence stability,water solubility,anti-interference and low cytotoxicity,and can be specifically combined with the detection of Cr(Ⅵ)to form a non-fluorescent complex that causes fluorescence quenching,so they can be used as a label-free nanosensor.High-sensitivity detection of Cr(Ⅵ)was achieved through internal filtering and static quenching effects.The fluorescence quenching degree of carbon dots fluorescent probe showed a good linear relationship with Cr(Ⅵ)concentration in the range of 1-100μM.The linear equation was F;/F=0.9942+0.01472[Cr(Ⅵ)](R;=0.9922),and the detection limit can be as low as 0.25μM(S/N=3),which has been successfully applied to Cr(Ⅵ)detection in actual water samples herein.展开更多
It is particularly important to monitor Cr(Ⅵ)for its high toxicity.In this paper,a novel,simple,low-cost and"on-off-on"fluorescence sensor of carbon dots doped with nitrogen and phosphorus(N,P-CDs)was devel...It is particularly important to monitor Cr(Ⅵ)for its high toxicity.In this paper,a novel,simple,low-cost and"on-off-on"fluorescence sensor of carbon dots doped with nitrogen and phosphorus(N,P-CDs)was developed via one-step hydrothermal method for highly sensitive and good selective detection of Cr(Ⅵ)and ascorbic acid(AA).The prepared N,P-CDs exhibited the ability for detection of Cr(Ⅵ)based on the inner filter effect(IFE)and static quenching.Under optimized conditions,the fluorescence quenching efficiency of N,P-CDs showed a good linear correlation with Cr(Ⅵ)concentration ranged from0.68 to 87.38μmol/L(R^(2)=0.9946).The limit of detection(LOD)was 0.18μmol/L,which was acceptable compared with the maximum Cr(Ⅵ)concentration of 0.96μmol/L in drinking water prescribed by WHO.In addition,the N,P-CDs/Cr(Ⅵ)hybrid were also used as"turn-on"fluorescent transducers for detecting AA with a wide linear region ranged from 0.02 to933.33μmol/L(R^(2)=0.9972).Furthermore,the N,P-CDs fluorescence sensor had admissible applicability for Cr(Ⅵ)and AA detection in actual water samples with acceptable recovery rate,indicating that the fluorescence sensor had great application potential in environmental monitoring and food field.展开更多
基金supported by the National Natural Science Foundation of China (Grant No.52279116)the Key Projects of the Yalong River Joint Fund of the National Natural Science Foundation of China (Grant No.U1865203).
文摘Seismicity resulting from the near-or in-field fault activation significantly affects the stability of large-scale underground caverns that are operating under high-stress conditions.A comprehensive scientific assessment of the operational safety of such caverns requires an in-depth understanding of the response characteristics of the rock mass subjected to dynamic disturbances.To address this issue,we conducted true triaxial modeling tests and dynamic numerical simulations on large underground caverns to investigate the impact of static stress levels,dynamic load parameters,and input directions on the response characteristics of the surrounding rock mass.The findings reveal that:(1)When subjected to identical incident stress waves and static loads,the surrounding rock mass exhibits the greatest stress response during horizontal incidence.When the incident direction is fixed,the mechanical response is more pronounced at the cavern wall parallel to the direction of dynamic loading.(2)A high initial static stress level specifically enhances the impact of dynamic loading.(3)The response of the surrounding rock mass is directly linked to the amplitude of the incident stress wave.High amplitude results in tensile damage in regions experiencing tensile stress concentration under static loading and shear damage in regions experiencing compressive stress concentration.These results have significant implications for the evaluation and prevention of dynamic disasters in the surrounding rock of underground caverns experiencing dynamic disturbances.
基金financial support of the National Key Research and Development Program of China(No.2017YFC0703803)the Joint Usage/Research Center(JURC)project“Wind-induced Load Estimation for Clips of Standing-seam Roofing System Considering Dynamic Characteristics”from Tokyo Polytechnic University(2018 FY)the National Natural Science Foundation of China(Grant No.51978500).
文摘This paper mainly focuses on the establishment of an effective static estimation method for the extreme wind-induced force for clips between purlins and metal panels of the standing-seam metal roofing system(hereinafter referred to as SMRS)of typical double-slope light-weight steel portal frame structure considering dynamic characteristics of wind and structure.First,simultaneous pressure measurement with rigid gable roof models was conducted mainly considering the length-span ratio in the boundary layer wind tunnel of Tokyo Polytechnic University,Japan.Then,finite element modeling for SMRS according to the wind load path in the roofing system was carried out to check the actual wind load of the clips based on the traditional calculation method provided in design codes,and the spatial correlation of fluctuating wind pressure on the roof surface,as well as the dynamic effect of the roof structure itself,had been considered.According to the related Chinese,American,and Japanese codes,a magnification coefficient based on the traditional method of static wind-induced force for the clips was calculated and compared.Finally,a simplified estimation method of effective wind-induced force for the clips in typical zones on the roof surface considering dynamic characteristics was proposed.
基金financially supported by the Natural Science Foundation of Anhui University of Chinese Medicine (Grant No.: 2018zrzd04)Anhui Provincial Natural Science Foundation (Grant No.: 1908085QH351)+2 种基金Major Science and Technology Projects of Anhui Province (Grant No.: 18030801131)National Key Research and Development Project (Grant No.: 2017YFC1701600)Anhui Province’s Central Special Fund for Local Science and Technology Development (Grant No.: 201907d07050002)
文摘Chromium is a harmful contaminant showing mutagenicity and carcinogenicity.Therefore,detection of chromium requires the development of low-cost and high-sensitivity sensors.Herein,blue-fluorescent carbon quantum dots were synthesized by one-step hydrothermal method from alkali-soluble Poria cocos polysaccharide,which is green source,cheap and easy to obtain,and has no pharmacological activity due to low water solubility.These carbon quantum dots exhibit good fluorescence stability,water solubility,anti-interference and low cytotoxicity,and can be specifically combined with the detection of Cr(Ⅵ)to form a non-fluorescent complex that causes fluorescence quenching,so they can be used as a label-free nanosensor.High-sensitivity detection of Cr(Ⅵ)was achieved through internal filtering and static quenching effects.The fluorescence quenching degree of carbon dots fluorescent probe showed a good linear relationship with Cr(Ⅵ)concentration in the range of 1-100μM.The linear equation was F;/F=0.9942+0.01472[Cr(Ⅵ)](R;=0.9922),and the detection limit can be as low as 0.25μM(S/N=3),which has been successfully applied to Cr(Ⅵ)detection in actual water samples herein.
基金financially sponsored by the National Natural Science Foundation of China(21777131,22176154)Science and Technology Department Foundation of Sichuan Province(22ZDYF1945)
文摘It is particularly important to monitor Cr(Ⅵ)for its high toxicity.In this paper,a novel,simple,low-cost and"on-off-on"fluorescence sensor of carbon dots doped with nitrogen and phosphorus(N,P-CDs)was developed via one-step hydrothermal method for highly sensitive and good selective detection of Cr(Ⅵ)and ascorbic acid(AA).The prepared N,P-CDs exhibited the ability for detection of Cr(Ⅵ)based on the inner filter effect(IFE)and static quenching.Under optimized conditions,the fluorescence quenching efficiency of N,P-CDs showed a good linear correlation with Cr(Ⅵ)concentration ranged from0.68 to 87.38μmol/L(R^(2)=0.9946).The limit of detection(LOD)was 0.18μmol/L,which was acceptable compared with the maximum Cr(Ⅵ)concentration of 0.96μmol/L in drinking water prescribed by WHO.In addition,the N,P-CDs/Cr(Ⅵ)hybrid were also used as"turn-on"fluorescent transducers for detecting AA with a wide linear region ranged from 0.02 to933.33μmol/L(R^(2)=0.9972).Furthermore,the N,P-CDs fluorescence sensor had admissible applicability for Cr(Ⅵ)and AA detection in actual water samples with acceptable recovery rate,indicating that the fluorescence sensor had great application potential in environmental monitoring and food field.