期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser 被引量:3
1
作者 Xilong Yu Fei Li Lihong Chen Xinyu Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2010年第1期147-149,共3页
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS... A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS. 展开更多
关键词 WMS-2fTDLAS - Profile fitting spatial resolved - Temperature measurement
在线阅读 下载PDF
Enhanced Detection of Glaucoma on Ensemble Convolutional Neural Network for Clinical Informatics 被引量:1
2
作者 D.Stalin David S.Arun Mozhi Selvi +4 位作者 S.Sivaprakash P.Vishnu Raja Dilip Kumar Sharma Pankaj Dadheech Sudhakar Sengan 《Computers, Materials & Continua》 SCIE EI 2022年第2期2563-2579,共17页
Irretrievable loss of vision is the predominant result of Glaucoma in the retina.Recently,multiple approaches have paid attention to the automatic detection of glaucoma on fundus images.Due to the interlace of blood v... Irretrievable loss of vision is the predominant result of Glaucoma in the retina.Recently,multiple approaches have paid attention to the automatic detection of glaucoma on fundus images.Due to the interlace of blood vessels and the herculean task involved in glaucoma detection,the exactly affected site of the optic disc of whether small or big size cup,is deemed challenging.Spatially Based Ellipse Fitting Curve Model(SBEFCM)classification is suggested based on the Ensemble for a reliable diagnosis of Glaucomain theOptic Cup(OC)and Optic Disc(OD)boundary correspondingly.This research deploys the Ensemble Convolutional Neural Network(CNN)classification for classifying Glaucoma or Diabetes Retinopathy(DR).The detection of the boundary between the OC and the OD is performed by the SBEFCM,which is the latest weighted ellipse fitting model.The SBEFCM that enhances and widens the multi-ellipse fitting technique is proposed here.There is a preprocessing of input fundus image besides segmentation of blood vessels to avoid interlacing surrounding tissues and blood vessels.The ascertaining of OCandODboundary,which characterizedmany output factors for glaucoma detection,has been developed by EnsembleCNNclassification,which includes detecting sensitivity,specificity,precision,andArea Under the receiver operating characteristic Curve(AUC)values accurately by an innovative SBEFCM.In terms of contrast,the proposed Ensemble CNNsignificantly outperformed the current methods. 展开更多
关键词 Glaucoma and diabetic retinopathy detection ensemble convolutional neural network spatially based ellipse fitting curve optic disk optic cup
在线阅读 下载PDF
Measurement of the anisotropy factor with azimuthal light backscattering
3
作者 王品 李勇明 陈勃翰 《Optoelectronics Letters》 EI 2014年第6期470-472,共3页
The potential capability of low coherence backscattering(LBS) is explored to determine the anisotropy factor based on azimuthal light backscattering map. The scattering intensity signal measured at azimuthal angle φ=... The potential capability of low coherence backscattering(LBS) is explored to determine the anisotropy factor based on azimuthal light backscattering map. The scattering intensity signal measured at azimuthal angle φ=0° is extracted for analysis. By performing nonlinear regression fitting on the experimental signal to the Henyey-Greenstein phase function, the anisotropy factor is determined. The experiments with tissue phantom consisting of the aqueous suspension of polystyrene microspheres are carried out. The results show that the measured anisotropy factor is well described by Mie theory. 展开更多
关键词 anisotropy polystyrene fitting performing coherence suspension scattered spatially directional illumination
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部