Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controlle...Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controller based on compensation for unbalanced source voltage and current. With the proposed scheme, the second harmonics of the output current are eliminated and low-order harmonics of the source current are reduced effectively. Simulation and experimental results con- firmed the feasibility of the proposed method.展开更多
This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented ...This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.展开更多
This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevi...This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.展开更多
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t...Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.展开更多
This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci...This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.展开更多
This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or ...This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.展开更多
the system to DC voltage source as the core, AT89C52 MCU as the main controller, the output voltage to set the DC power supply through the keyboard, with a step function voltage to reality, the actual output value. Th...the system to DC voltage source as the core, AT89C52 MCU as the main controller, the output voltage to set the DC power supply through the keyboard, with a step function voltage to reality, the actual output value. This design is divided into four modules: SCM control and display module, digital to analog (D/A) conversion module, a constant voltage source module, output module. MCU control module as the core, the input signal is converted to digital quantity output; constant current source module voltage D/A conversion to analog conversion into constant pressure through a constant voltage circuit. The system has good reliability, high precision.展开更多
In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the...In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the gird parameters rising by its variable demands and other related issues may humiliate the efficiency with which power can be injected into the grid. The system becomes a higher order one with the filters used at the terminal of the Voltage Source Inverter (VSI) along with the parameters of the grid which change from time to time. Single time tuned mathematical controllers like the PID variants are not suitable for such applications. Considering the increased order of the system and the associated non-linearity we have to look out for intelligent controllers. An ANFIS based control is found to be promising;the development and implementation of one such are demonstrated in this paper using the MATLAB SIMULINK platform and through experimental verification using the Reduced Instruction Set Computer (RISC) Microcontroller Advanced RISC Machine (ARM) processor as the central controller for the VSI.展开更多
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f...This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.展开更多
This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ...This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.展开更多
A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-fie...A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications.展开更多
This work presents the smart grid system for distributed Renewable Energy Sources(RES)with control methods.The hybrid MicroGrids(MG)are trending in small-scale power systems that involve distributed generations,power ...This work presents the smart grid system for distributed Renewable Energy Sources(RES)with control methods.The hybrid MicroGrids(MG)are trending in small-scale power systems that involve distributed generations,power storage,and various loads.RES of solar are implemented with boost converter using Maximum Power Point Tracking(MPPT)with perturb and observe technique to track the maximum power.Also,the wind system is designed by permanent magnet synchronous generator that includes boost converter with MPPT technique.The battery is also employed with a Direct Current(DC)-DC bidirectional converter,and has a state of charge.The MATLAB/Simulink Simscape software is used to design the proposed model.The switching element of all converters is metal oxide semiconductor field effect transistor.The hybrid system is controlled by a voltage source controller using Proportional Integral Derivative(PID)-Genetic Algorithm(GA),and inductors-capacitors filter is used to reduce the system’s harmonics.Also,smart meters are used for monitoring purposes in residential loads.This paper analyses the performances of the MG against various scenarios.展开更多
We investigate the influence of source and drain bias voltages(V_(DS))on the quantum sub-band transport spectrum in the 10-nm width N-typed junctionless nanowire transistor at the low temperature of 6 K.We demonstrate...We investigate the influence of source and drain bias voltages(V_(DS))on the quantum sub-band transport spectrum in the 10-nm width N-typed junctionless nanowire transistor at the low temperature of 6 K.We demonstrate that the transverse electric field introduced from V_(DS) has a minor influence on the threshold voltage of the device.The transverse electric field plays the role of amplifying the gate restriction effect of the channel.The one-dimensional(1D)-band dominated transport is demonstrated to be modulated by V_(DS) in the saturation region and the linear region,with the sub-band energy levels in the channel(E_(channel))intersecting with Fermi levels of the source(E_(fS))and the drain(E_(fD))in turn as V_(g) increases.The turning points from the linear region to the saturation region shift to higher gate voltages with V_(DS) increase because the higher Fermi energy levels of the channel required to meet the situation of E_(fD)=E_(channel).We also find that the bias electric field has the effect to accelerate the thermally activated electrons in the channel,equivalent to the effect of thermal temperature on the increase of electron energy.Our work provides a detailed description of the bias-modulated quantum electronic properties,which will give a more comprehensive understanding of transport behavior in nanoscale devices.展开更多
The 3Φinduction motor is a broadly used electric machine in industrial applications,which plays a vital role in industries because of having plenty of beneficial impacts like low cost and easiness but the problems lik...The 3Φinduction motor is a broadly used electric machine in industrial applications,which plays a vital role in industries because of having plenty of beneficial impacts like low cost and easiness but the problems like decrease in motor speed due to load,high consumption of current and high ripple occurrence of ripples have reduced its preferences.The ultimate objective of this study is to control change in motor speed due to load variations.An improved Trans Z Source Inverter(ΓZSI)with a clamping diode is employed to maintain constant input voltage,reduce ripples and voltage overshoot.To operate induction motor at rated speed,different controllers are used.The conventional Proportional-Inte-gral(PI)controller suffers from high settling time and maximum peak overshoot.To overcome these limitations,Fractional Order Proportional Integral Derivative(FOPID)controller optimized by Gray Wolf Optimization(GWO)technique is employed to provide better performance by eliminating maximum peak overshoot pro-blems.The proposed speed controller provides good dynamic response and controls the induction motor more effectively.The complete setup is implemented in MATLAB Simulation to verify the simulation results.The proposed approach provides optimal performance with high torque and speed along with less steady state error.展开更多
This project proposes a novel dual-input matrix converter (DIMC) which is used to integrate the output of the wind energy to a power grid. The proposed matrix converter is developed based on the traditional indirect m...This project proposes a novel dual-input matrix converter (DIMC) which is used to integrate the output of the wind energy to a power grid. The proposed matrix converter is developed based on the traditional indirect matrix converter under reverse power flow operation mode, but with its six-switch voltage source converter replaced by a nine-switch configuration followed by the current source inverter (CSI). Matrix electric power conversion topologies and their switch functions are flexible and are used for specific applications. With the additional three switches, the proposed DIMC can provide six input terminals, which make it possible to integrate two independent AC sources from two independent wind turbines into a single grid tied power electronics interface. Commanded currents can be extracted from the two input sources to the grid. The proposed PI control and modulation schemes guaranteed sinusoidal input and output waveforms as well as reduced THD. The simulation results are provided to validate the effectiveness of the proposed control and modulation schemes for the proposed converter.展开更多
The integration of renewable energy sources(RESs)via voltage source converters(VSCs)has introduced considerable risk to the transient stability of power systems,necessitating accurate transient stability assessment th...The integration of renewable energy sources(RESs)via voltage source converters(VSCs)has introduced considerable risk to the transient stability of power systems,necessitating accurate transient stability assessment through estimating the region of attraction(ROA).This review systematically examines methodologies for ROA estimation in power systems integrated with VSCs.The key challenges in ROA estimation arise from various nonlinearities,multi-timescale control interactions,and structural switching in system models.The review categorizes ROA estimation methods into non-direct methods(e.g.,timedomain simulation method,stable manifold method)and direct methods(e.g.,energy function method,Lyapunov function method).The basic principles of these methods and their advantages and limitations are summarized.Future directions for estimating the ROA of power systems integrated with VSCs are outlined and discussed.This work serves as a comprehensive resource for advancing ROA estimation and various applications based on ROA estimation in VSC integrated power systems.展开更多
The self-synchronizing voltage source inverter(SS VSI)is widely studied because of its grid-forming capability.However,the slow response of the active power control loop(APCL)under the weak grid makes it difficult for...The self-synchronizing voltage source inverter(SS VSI)is widely studied because of its grid-forming capability.However,the slow response of the active power control loop(APCL)under the weak grid makes it difficult for the SSVSI to quickly support the frequency of a low-inertia grid.In this pa per,a grid framework is established to analyze the frequency support service process of the SSVSI,and the shortcomings of the regulation of the damping coefficient and virtual inertia co efficient for frequency support are analyzed.Then,an adaptive additional damping control method is proposed to optimize the ability of SSVSI to support the grid frequency.The proposed control method adjusts the damping of the APCL without affect ing the system steady-state characteristics,which improves the active power response speed of the SSVSI.Besides,the pro posed control method adaptively adjusts the additional damp ing coefficient based on the active power response without mea suring the grid parameters.Compared with other forms of con trol,the proposed control method excels in minimizing the rate of change of frequency(RoCoF)and the frequency deviation(FD)within the grid,without succumbing to the constraints posed by unknown grid parameters.Furthermore,the analysis of the system stability is also presented.Finally,the experimen tal hardware results obtained from a miniaturized grid proto type are presented,corroborating the effectiveness of the pro posed control method.展开更多
Flexible interconnection devices(FIDs)significantly enhance the regulation and management of complex power flows in distribution networks.Voltage source converter(VSC)-based FIDs,in particular,are pivotal for increasi...Flexible interconnection devices(FIDs)significantly enhance the regulation and management of complex power flows in distribution networks.Voltage source converter(VSC)-based FIDs,in particular,are pivotal for increasing system reliability and operational efficiency.These devices are crucial in supporting the extensive incorporation of electric vehicles(EVs)and renewable energy sources(RESs)into new,load-centric environments.This study evaluates four unique FID-based configurations for distribution network interconnections,revealing their distinctive features.We developed a comprehensive evaluation framework and tool by integrating the analytic hierarchy process(AHP)and fuzzy comprehensive evaluation(FCE),which includes five key performance indicators to assess these configurations.The study identifies the optimal application scenarios for each configuration and discusses their roles in enabling the seamless integration of EVs and RESs.The findings provide essential insights and guidelines for the design and implementation of adaptable,interconnected distribution networks that are equipped to meet the growing demands of future urban environments.展开更多
A control strategy of repetitive control without inductorance decoupling was proposed to address the problem of high total harmonic distortion(THD)rate of the network-side current caused by the reduced stability of th...A control strategy of repetitive control without inductorance decoupling was proposed to address the problem of high total harmonic distortion(THD)rate of the network-side current caused by the reduced stability of the rectifier module of the DC charging pile under weak grid as well as the dead zone and nonlinearity of switching devices during charging.Firstly,the parallel repetitive control was constructed in the inner current loop,and the proportional-integral(PI)+repetitive controller based on parallel structure was designed.For system compensation,a second-order low-pass filter was selected to correct the system,and the network-side current harmonics were actively suppressed without increasing the filtering device,which effectively improves the quality of grid-connected current.Secondly,based on the synthetic vector method,the controller parameters were designed to realize the elimination of main pole by establishing two synchronous rotation coordinate system vector differential equations,so as to realize the inductanceless decoupling to cope with the influence of network-side inductance fluctuation on the stability of the control system under weak grid.By theoretical analysis and simulation,the proposed control strategy was embedded into the self-developed digital signal processor for the rectifier module of DC charging pile,simulated dynamic and steady-state operation experiments were conducted,and comparative analysis was performed to prove the feasibility of the proposed control strategy.展开更多
Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging asp...Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging aspects of VSCs under fault conditions.Therefore,fault current limitation and power angle stability are essential conditions for the safe operation of a VSC.Thus,the transient characteristics of a VSC are analyzed to guide transient control.Then,a transient control method for a VSC,considering both fault current limitation and power angle stability,is proposed.With the proposed method,power angle stability is realized by optimizing the P-f controller.On the basis of power angle control,the Q-U controller and inner current controller are improved to effectively suppress the fault current.Finally,relevant tests are performed to verify the proposed method.展开更多
基金Project (No. 50477033) supported by the National Nature ScienceFoundation of China
文摘Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controller based on compensation for unbalanced source voltage and current. With the proposed scheme, the second harmonics of the output current are eliminated and low-order harmonics of the source current are reduced effectively. Simulation and experimental results con- firmed the feasibility of the proposed method.
基金supported by the National Natural Science Foundation of China(No.50907057)the National High-Tech Research and Development Program (863) of China(No.2007AA05Z419)
文摘This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.
文摘This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.
文摘Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.
基金This work is supported by the National Key Research and Development Program of China under Project 2021YFB2601600。
文摘This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.
文摘This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.
文摘the system to DC voltage source as the core, AT89C52 MCU as the main controller, the output voltage to set the DC power supply through the keyboard, with a step function voltage to reality, the actual output value. This design is divided into four modules: SCM control and display module, digital to analog (D/A) conversion module, a constant voltage source module, output module. MCU control module as the core, the input signal is converted to digital quantity output; constant current source module voltage D/A conversion to analog conversion into constant pressure through a constant voltage circuit. The system has good reliability, high precision.
文摘In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the gird parameters rising by its variable demands and other related issues may humiliate the efficiency with which power can be injected into the grid. The system becomes a higher order one with the filters used at the terminal of the Voltage Source Inverter (VSI) along with the parameters of the grid which change from time to time. Single time tuned mathematical controllers like the PID variants are not suitable for such applications. Considering the increased order of the system and the associated non-linearity we have to look out for intelligent controllers. An ANFIS based control is found to be promising;the development and implementation of one such are demonstrated in this paper using the MATLAB SIMULINK platform and through experimental verification using the Reduced Instruction Set Computer (RISC) Microcontroller Advanced RISC Machine (ARM) processor as the central controller for the VSI.
文摘This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.
基金Project (No. 50577056) supported by the National Natural ScienceFoundation of China
文摘This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.
基金National High-tech Research & Development Plan(863 Projeet)(No.2008AA062317)National Natural Science Foundation of China(No.50578020)
文摘A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications.
文摘This work presents the smart grid system for distributed Renewable Energy Sources(RES)with control methods.The hybrid MicroGrids(MG)are trending in small-scale power systems that involve distributed generations,power storage,and various loads.RES of solar are implemented with boost converter using Maximum Power Point Tracking(MPPT)with perturb and observe technique to track the maximum power.Also,the wind system is designed by permanent magnet synchronous generator that includes boost converter with MPPT technique.The battery is also employed with a Direct Current(DC)-DC bidirectional converter,and has a state of charge.The MATLAB/Simulink Simscape software is used to design the proposed model.The switching element of all converters is metal oxide semiconductor field effect transistor.The hybrid system is controlled by a voltage source controller using Proportional Integral Derivative(PID)-Genetic Algorithm(GA),and inductors-capacitors filter is used to reduce the system’s harmonics.Also,smart meters are used for monitoring purposes in residential loads.This paper analyses the performances of the MG against various scenarios.
基金the National Key Research and Development Program of China(Grant No.2016YFA0200503).
文摘We investigate the influence of source and drain bias voltages(V_(DS))on the quantum sub-band transport spectrum in the 10-nm width N-typed junctionless nanowire transistor at the low temperature of 6 K.We demonstrate that the transverse electric field introduced from V_(DS) has a minor influence on the threshold voltage of the device.The transverse electric field plays the role of amplifying the gate restriction effect of the channel.The one-dimensional(1D)-band dominated transport is demonstrated to be modulated by V_(DS) in the saturation region and the linear region,with the sub-band energy levels in the channel(E_(channel))intersecting with Fermi levels of the source(E_(fS))and the drain(E_(fD))in turn as V_(g) increases.The turning points from the linear region to the saturation region shift to higher gate voltages with V_(DS) increase because the higher Fermi energy levels of the channel required to meet the situation of E_(fD)=E_(channel).We also find that the bias electric field has the effect to accelerate the thermally activated electrons in the channel,equivalent to the effect of thermal temperature on the increase of electron energy.Our work provides a detailed description of the bias-modulated quantum electronic properties,which will give a more comprehensive understanding of transport behavior in nanoscale devices.
文摘The 3Φinduction motor is a broadly used electric machine in industrial applications,which plays a vital role in industries because of having plenty of beneficial impacts like low cost and easiness but the problems like decrease in motor speed due to load,high consumption of current and high ripple occurrence of ripples have reduced its preferences.The ultimate objective of this study is to control change in motor speed due to load variations.An improved Trans Z Source Inverter(ΓZSI)with a clamping diode is employed to maintain constant input voltage,reduce ripples and voltage overshoot.To operate induction motor at rated speed,different controllers are used.The conventional Proportional-Inte-gral(PI)controller suffers from high settling time and maximum peak overshoot.To overcome these limitations,Fractional Order Proportional Integral Derivative(FOPID)controller optimized by Gray Wolf Optimization(GWO)technique is employed to provide better performance by eliminating maximum peak overshoot pro-blems.The proposed speed controller provides good dynamic response and controls the induction motor more effectively.The complete setup is implemented in MATLAB Simulation to verify the simulation results.The proposed approach provides optimal performance with high torque and speed along with less steady state error.
文摘This project proposes a novel dual-input matrix converter (DIMC) which is used to integrate the output of the wind energy to a power grid. The proposed matrix converter is developed based on the traditional indirect matrix converter under reverse power flow operation mode, but with its six-switch voltage source converter replaced by a nine-switch configuration followed by the current source inverter (CSI). Matrix electric power conversion topologies and their switch functions are flexible and are used for specific applications. With the additional three switches, the proposed DIMC can provide six input terminals, which make it possible to integrate two independent AC sources from two independent wind turbines into a single grid tied power electronics interface. Commanded currents can be extracted from the two input sources to the grid. The proposed PI control and modulation schemes guaranteed sinusoidal input and output waveforms as well as reduced THD. The simulation results are provided to validate the effectiveness of the proposed control and modulation schemes for the proposed converter.
基金supported by the Department of Science,and Technology of Guangdong Province under Grant No.2023A1515240019the National Natural Science Foundation of China under Grant No.52207106.
文摘The integration of renewable energy sources(RESs)via voltage source converters(VSCs)has introduced considerable risk to the transient stability of power systems,necessitating accurate transient stability assessment through estimating the region of attraction(ROA).This review systematically examines methodologies for ROA estimation in power systems integrated with VSCs.The key challenges in ROA estimation arise from various nonlinearities,multi-timescale control interactions,and structural switching in system models.The review categorizes ROA estimation methods into non-direct methods(e.g.,timedomain simulation method,stable manifold method)and direct methods(e.g.,energy function method,Lyapunov function method).The basic principles of these methods and their advantages and limitations are summarized.Future directions for estimating the ROA of power systems integrated with VSCs are outlined and discussed.This work serves as a comprehensive resource for advancing ROA estimation and various applications based on ROA estimation in VSC integrated power systems.
基金supported by the Natural Science Foundation of China(No.52077070)Young Scientists Fund of National Natural Science Foundation of China(No.52207201)+1 种基金Hunan Provincial Natural Science Foundation of China(No.2024JJ3012)Young Scientists Fund of Hunan Provincial Natural Science Foundation of China(No.2024JJ6172).
文摘The self-synchronizing voltage source inverter(SS VSI)is widely studied because of its grid-forming capability.However,the slow response of the active power control loop(APCL)under the weak grid makes it difficult for the SSVSI to quickly support the frequency of a low-inertia grid.In this pa per,a grid framework is established to analyze the frequency support service process of the SSVSI,and the shortcomings of the regulation of the damping coefficient and virtual inertia co efficient for frequency support are analyzed.Then,an adaptive additional damping control method is proposed to optimize the ability of SSVSI to support the grid frequency.The proposed control method adjusts the damping of the APCL without affect ing the system steady-state characteristics,which improves the active power response speed of the SSVSI.Besides,the pro posed control method adaptively adjusts the additional damp ing coefficient based on the active power response without mea suring the grid parameters.Compared with other forms of con trol,the proposed control method excels in minimizing the rate of change of frequency(RoCoF)and the frequency deviation(FD)within the grid,without succumbing to the constraints posed by unknown grid parameters.Furthermore,the analysis of the system stability is also presented.Finally,the experimen tal hardware results obtained from a miniaturized grid proto type are presented,corroborating the effectiveness of the pro posed control method.
基金supported by the Science and Technology Project of the China Southern Power Grid Co.,Ltd.(Project number:SZKJXM20230085).
文摘Flexible interconnection devices(FIDs)significantly enhance the regulation and management of complex power flows in distribution networks.Voltage source converter(VSC)-based FIDs,in particular,are pivotal for increasing system reliability and operational efficiency.These devices are crucial in supporting the extensive incorporation of electric vehicles(EVs)and renewable energy sources(RESs)into new,load-centric environments.This study evaluates four unique FID-based configurations for distribution network interconnections,revealing their distinctive features.We developed a comprehensive evaluation framework and tool by integrating the analytic hierarchy process(AHP)and fuzzy comprehensive evaluation(FCE),which includes five key performance indicators to assess these configurations.The study identifies the optimal application scenarios for each configuration and discusses their roles in enabling the seamless integration of EVs and RESs.The findings provide essential insights and guidelines for the design and implementation of adaptable,interconnected distribution networks that are equipped to meet the growing demands of future urban environments.
基金supported by National Natural Science Foundation of China(No.61903291)Shaanxi Province Key R&D Program(No.2022GY-134)。
文摘A control strategy of repetitive control without inductorance decoupling was proposed to address the problem of high total harmonic distortion(THD)rate of the network-side current caused by the reduced stability of the rectifier module of the DC charging pile under weak grid as well as the dead zone and nonlinearity of switching devices during charging.Firstly,the parallel repetitive control was constructed in the inner current loop,and the proportional-integral(PI)+repetitive controller based on parallel structure was designed.For system compensation,a second-order low-pass filter was selected to correct the system,and the network-side current harmonics were actively suppressed without increasing the filtering device,which effectively improves the quality of grid-connected current.Secondly,based on the synthetic vector method,the controller parameters were designed to realize the elimination of main pole by establishing two synchronous rotation coordinate system vector differential equations,so as to realize the inductanceless decoupling to cope with the influence of network-side inductance fluctuation on the stability of the control system under weak grid.By theoretical analysis and simulation,the proposed control strategy was embedded into the self-developed digital signal processor for the rectifier module of DC charging pile,simulated dynamic and steady-state operation experiments were conducted,and comparative analysis was performed to prove the feasibility of the proposed control strategy.
基金supported in part by the National Natural Science Foundation of China(51907057 and 52077072)Technological Leading Talent of Hunan province(2019RS3014).
文摘Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging aspects of VSCs under fault conditions.Therefore,fault current limitation and power angle stability are essential conditions for the safe operation of a VSC.Thus,the transient characteristics of a VSC are analyzed to guide transient control.Then,a transient control method for a VSC,considering both fault current limitation and power angle stability,is proposed.With the proposed method,power angle stability is realized by optimizing the P-f controller.On the basis of power angle control,the Q-U controller and inner current controller are improved to effectively suppress the fault current.Finally,relevant tests are performed to verify the proposed method.