期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Identification of m = 2 competent mode of complex magneto-hydro-dynamics activities during internal soft disruption based on singular value decomposition and tomography of soft-X-ray emission on the HT-7 tokamak
1
作者 徐立清 胡立群 +8 位作者 李二众 陈开云 刘志远 陈晔斌 张继宗 周瑞杰 杨茂 毛松涛 段艳敏 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期418-423,共6页
In this paper,the singular value decomposition(SVD) method as a filter is applied before the tomographic inversion of soft-X-ray emission.Series of 'filtered' signals including specific chronos and topos are obtai... In this paper,the singular value decomposition(SVD) method as a filter is applied before the tomographic inversion of soft-X-ray emission.Series of 'filtered' signals including specific chronos and topos are obtained.(Here,chronos and topos are the decomposed spatial vectors and the decomposed temporal vectors,respectively).Given specific magnetic flux function with coupling m = 1 and m = 2 modes,the line-integrated soft-X-ray signals at all chords have been obtained.Then m = 1 and m = 2 modes have been identified by tomography of simulated 'filtered' signals extracted by the SVD method.Finaly,using the experimental line-integrated soft-X-ray signals,m = 2 competent mode of complex magnetohydrodynamics(MHD) activities during internal soft disruption is observed.This result demonstrates that m = 2 mode plays an important role in internal disruption(Here,m is the poloidal mode number). 展开更多
关键词 singular value decomposition DISRUPTION soft-x-ray tomography TOKAMAK
原文传递
Testifying experiment of the multi-pulse phenomena of capillary discharge soft-X-ray laser
2
作者 栾伯晗 赵永蓬 +2 位作者 王骐 程元丽 谢耀 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第5期353-355,共3页
In a capillary discharge experiment for the neon-like argon lasing, we have proposed an experimental scheme to verify that the multi-spike of X-ray diode (XRD) signal is a multi-pulse laser or is a reflection of the... In a capillary discharge experiment for the neon-like argon lasing, we have proposed an experimental scheme to verify that the multi-spike of X-ray diode (XRD) signal is a multi-pulse laser or is a reflection of the laser pulse in the XRD. The ceramic capillary has an inner diameter of 3 mm and a length of 200 mm. At the gas pressure of 28 Pa and discharge current of 27 kA, stable lasing has been realized. The experimental results prove that the multi-spike of XRD signal is a reflection of the electromagnetic signal produced by the laser pulse in the XRD. The improved electrocircuit scheme of the XRD to minimize the reflection phenomena is also found. 展开更多
关键词 XRD Testifying experiment of the multi-pulse phenomena of capillary discharge soft-x-ray laser
原文传递
Transmission measurement of photo-absorption cross section of aluminum in soft X-ray region of 50 to 250 eV
3
作者 陈凯 崔明启 郑雷 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第8期673-676,共4页
The photo-absorption cross section of aluminum was obtained from the ratio of transmission of aluminum thin-films with different area densities from 50 to 250 eV with synchrotron radiation monochromatic beam. Two samp... The photo-absorption cross section of aluminum was obtained from the ratio of transmission of aluminum thin-films with different area densities from 50 to 250 eV with synchrotron radiation monochromatic beam. Two samples with different area densities were used to minimize the uncertainty caused by the sample surface oxidation and systematic factors of the X-ray source, beamline, and detector. The experimental results are in good agreement with the published data and FEFF program calculations in general. 展开更多
关键词 synchrotron radiation soft-x-ray aluminum thin-film photo-absorption cross section
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部