Development of the Separate Air-Supply Type of Pressurization Smoke Control System for the Stairwells of High-Rise Buildings in Korea
1
作者 Jung-Yup Kim Hyun-Joon Shin +2 位作者 Chan-Sol Ahn Ji-Seok Kim Sang-Hyun Joo 《Open Journal of Fluid Dynamics》 2014年第3期251-262,共12页
The pressurization smoke control system has been commonly used as a smoke control system at the emergency stairs of high-rise buildings. However, a higher possibility of overpressure between the lobby and the accommod... The pressurization smoke control system has been commonly used as a smoke control system at the emergency stairs of high-rise buildings. However, a higher possibility of overpressure between the lobby and the accommodation or pressure drop in the lobby could lead to failure in achievement of the purpose of pressurization system, particularly when supplying the leakage and supplementary air flow through one air-supply path at a time. To improve this particular issue, the devise configurations, as well as the different ways to supply the leakage and supplementary air flow through the different flow passages have been proposed. The performance of the trial product was evaluated on the test bed, ultimately providing a safe evacuation environment if high-rise buildings fired. 展开更多
关键词 PRESSURIZATION system smoke control HIGH-RISE Building EVACUATION STAIRWELL Field EXPERIMENT
暂未订购
Design of Mechanical Smoke Exhaust System in Large Space of Convention Center 被引量:1
2
作者 Jung-Yup Kim Chan-Sol Ahn 《Open Journal of Fluid Dynamics》 2017年第3期386-396,共11页
The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area... The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area, comparing to normal-scale building, design and operation of effective smoke control system for large space is more than important. In this study, with the analysis model for such a large space as exhibition hall or conference room in conventional center, design of mechanical smoke exhaust system was conducted based on currently-available design standard which was then followed by numerical analysis of the design using 3D numerical analysis method. For conference room at 2.0 MW heat release rate, 99,173 CMH flow rate is required, if smoke layer is maintained at 60% of the floor height and for exhibition hall at 8.8 MW with 80% of floor height, flow rate required is 219,802 CMH, which are incorporated into the design. In view of 3D numerical analysis, accuracy of the design according to algebraic expression is sufficient. 展开更多
关键词 smoke control Mechanical EXHAUST system Large Space CONVENTION CENTER NUMERICAL Analysis
暂未订购
Application of Smoke Control and Exhaust Construction Technology in High-rise Building HVAC Fire Protection Engineering
3
作者 ZHOUBin 《外文科技期刊数据库(文摘版)工程技术》 2022年第4期014-018,共5页
At present, with the rapid development of China's economy, the integration of urban and rural areas has been strengthened to ease the tension in the housing field, and the number of high-rise residential buildings... At present, with the rapid development of China's economy, the integration of urban and rural areas has been strengthened to ease the tension in the housing field, and the number of high-rise residential buildings and shopping malls has been increasing, which has brought great difficulties to the fire control work. In the process of design and construction, combined with the requirements of fire control management in the new era, attention should be paid to centralized control of smoke control devices and HVAC fire fighting equipment, so as to ensure the quality of HVAC fire fighting projects, reduce the possibility of fire and other accidents, and protect the safety of people's lives and property. 展开更多
关键词 high-rise building HEATING ventilating and fire fighting engineering smoke control technology construction application
原文传递
传染病医院通风、空调与防排烟系统设计浅析
4
作者 张静 《绿色建造与智能建筑》 2026年第1期148-150,共3页
针对传染病医院内通风、空调与防排烟系统设计复杂且室内管道多的问题,结合多个典型传染病医院项目设计案例,对传染病医院建筑内通风系统、空调系统与防排烟系统设计进行总结归纳,得出传染病医院项目内部通风、空调与防排烟系统设计方案... 针对传染病医院内通风、空调与防排烟系统设计复杂且室内管道多的问题,结合多个典型传染病医院项目设计案例,对传染病医院建筑内通风系统、空调系统与防排烟系统设计进行总结归纳,得出传染病医院项目内部通风、空调与防排烟系统设计方案,为传染病医院项目通风、空调及防排烟系统设计与应用提供参考依据。 展开更多
关键词 传染病医院 通风系统 空调系统 防排烟系统
在线阅读 下载PDF
Smoke movement in a tunnel of a running metro train on fire 被引量:4
5
作者 周丹 田红旗 +1 位作者 郑晋丽 颜鑫 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期208-213,共6页
Research on the distribution of smoke in tunnels is significant for the fire emergency rescue after an operating metro train catches fire. A dynamic grid technique was adopted to research the law of smoke flow diffusi... Research on the distribution of smoke in tunnels is significant for the fire emergency rescue after an operating metro train catches fire. A dynamic grid technique was adopted to research the law of smoke flow diffusion inside the tunnel when the bottom of a metro train was on fire and to compare the effect of longitudinal ventilation modes on the smoke motion when the burning train stopped. Research results show that the slipstream curves around the train obtained by numerical simulation are consistent with experimental data. When the train decelerates, the smoke flow first extends to the tail of the train. With the decrease of the train's speed, the smoke flow diffuses to the head of the train. After the train stops, the slipstream around the train formed in the process of train operation plays a leading role in the smoke diffusion in the tunnel. The smoke flow quickly diffuses to the domain in front of the train. After forward mechanical ventilation is provided, the smoke flow inside the tunnel continues to diffuse downstream. When reverse mechanical ventilation operates, the smoke in front of the train flows back rapidly and diffuses to the rear of the train. 展开更多
关键词 subway tunnel train catching fire moving fire source smoke movement ventilation control
在线阅读 下载PDF
Small-scale fire tests in the underwater tunnel section model with new sidewall smoke extraction
6
作者 Shunyu Yue Ruifeng Miao +2 位作者 Huihang Cheng Maohua Zhong Xiujun Yang 《Deep Underground Science and Engineering》 2024年第2期247-254,共8页
The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the t... The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels. 展开更多
关键词 sidewall smoke extraction system small‐scale fire tests smoke control
原文传递
Impact of Village-based Health Education of Tobacco Control on the Current Smoking Rate in Chinese Rural Areas
7
作者 王坚苗 熊维宁 +4 位作者 谢俊刚 刘先胜 赵建平 张珍祥 徐永健 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第1期150-152,共3页
The number of smokers in Chinese rural areas is more than 200 million, which is twice that in cities. It is very significant to carry out tobacco control interventions in rural areas. We performed this community inter... The number of smokers in Chinese rural areas is more than 200 million, which is twice that in cities. It is very significant to carry out tobacco control interventions in rural areas. We performed this community intervention study to evaluate the efficacy of village-based health education of tobacco control on the male current smoking rate in rural areas. The population of this study was the males above 15 years old from 6 villages in rural areas. The villages were randomly assigned to intervention group or control group(3 villages in each group). Self-designed smoking questionnaire was applied. The intervention group received the village-based health education of tobacco control for one year. The primary outcome measurement was the male current smoking rate. In the baseline investigation, completed surveys were returned by 814 male residents from the control group and 831 male residents from the intervention group. The male current smoking rate in the control group and the intervention group was 61.2% and 58.5%, respectively, before intervention. There was no significant difference between these two groups(P〉0.05). After one-year intervention, the current smoking rate in the intervention group(51.2%) was significantly lower than that in the control group(62.8%)(P〈0.001). Our study suggested that the village-based health education of tobacco control was effective in lowering the male current smoking rate in rural areas, which could be a suitable and feasible way for tobacco control in the Chinese rural areas. 展开更多
关键词 health education rural areas smoking rate tobacco control
暂未订购
非对称V形隧道火灾重点排烟排烟效果的试验研究 被引量:1
8
作者 郄宇洲 李俊梅 +1 位作者 刘文博 郭志成 《消防科学与技术》 北大核心 2025年第3期356-361,共6页
为研究非对称V形隧道重点排烟时的烟气控制效果,采用了比例模型试验的方法,以20 MW设计火灾为例,在研究一般隧道重点排烟合理排烟量的基础上,针对V形隧道,研究当火源位于变坡点时,不同坡度组合及不同排烟阀开启方式对烟气控制效果的影... 为研究非对称V形隧道重点排烟时的烟气控制效果,采用了比例模型试验的方法,以20 MW设计火灾为例,在研究一般隧道重点排烟合理排烟量的基础上,针对V形隧道,研究当火源位于变坡点时,不同坡度组合及不同排烟阀开启方式对烟气控制效果的影响。研究结果表明:针对20 MW的设计火灾,能将烟气进行有效控制的合理排烟量约为140 m^(3)/s。对于V形隧道,当火源两侧对称地开启3个排烟口,无法有效地控制大坡度侧的烟气扩散时,可以考虑适当增加大坡度侧的排烟阀开启数量;V形不对称隧道两侧坡度差太大,尤其大坡度侧坡度值过大时,对烟气实施有效控制较为困难。 展开更多
关键词 V形隧道 火灾 比例模型试验 重点排烟 烟气控制
在线阅读 下载PDF
地铁车站防排烟系统精细化控制模式研究
9
作者 侯春源 朱国庆 +1 位作者 端木祥玲 周鹏 《消防科学与技术》 北大核心 2025年第7期917-922,共6页
以北京市某标准地下三层换乘车站为研究对象,针对地下三层站台层发生不同类型火灾,利用PyroSim软件开展不同火源位置、热释放速率和排烟模式下火灾烟气数值模拟,研究不同烟控模式对站台层火灾烟气的控制效果,实现地铁站台层火灾防排烟... 以北京市某标准地下三层换乘车站为研究对象,针对地下三层站台层发生不同类型火灾,利用PyroSim软件开展不同火源位置、热释放速率和排烟模式下火灾烟气数值模拟,研究不同烟控模式对站台层火灾烟气的控制效果,实现地铁站台层火灾防排烟系统精细化控制。结果表明:无论发生站台层行李火灾还是列车火灾,在标准地铁车站站台层划分防烟分区有利于火灾烟气控制和人员安全疏散。对于站台层行李火灾,通过站台层防烟分区内排烟风机和站厅层空调系统机械补风能够有效防止烟气通过楼扶梯口由站台层向站厅层蔓延,且烟气控制效果最好;对于列车火灾,控制烟气蔓延主要依靠轨顶排热风机和隧道风机,同时开启站台层列车火灾相邻防烟分区排烟风机,对烟气控制效果最好。同时,通过对楼扶梯洞口风速统计可知,对于站台层行李火灾,由于火源功率较小,楼扶梯洞口局部下行风速低于1.5 m/s也能有效控制烟气不向站厅层蔓延;对于列车火灾,上述烟控模式能够保证每个楼梯洞口下行风速满足规范的同时最接近1.5 m/s,更有利于人员安全疏散。 展开更多
关键词 地铁车站 防排烟系统 烟控模式 数值模拟 下行风速
在线阅读 下载PDF
Numerical studies on the synergistic effects of smoke extraction and control performance by mechanical ventilation shafts during tunnel fires 被引量:1
10
作者 Bin Zhu Haiyong Cong +4 位作者 Zhuyu Shao Hairuo Hu Lili Ye Yubo Bi Yiping Zeng 《Underground Space》 2025年第2期44-64,共21页
High smoke extraction efficiency and a relatively stable smoke layer stratification are both expected in tunnel ventilation systems.The purpose of this paper is to explore the overall performance of mechanical board-c... High smoke extraction efficiency and a relatively stable smoke layer stratification are both expected in tunnel ventilation systems.The purpose of this paper is to explore the overall performance of mechanical board-coupled shaft under different ventilation strategies.A total of 57 simulations were conducted,and the effects of the distance between the shaft and board(hp)and ventilation velocity on the overall performance were investigated.The results indicate that the performance of smoke extraction and control will be improved by the application of mechanical ventilation and board.Smoke movement patterns under different working conditions were dfferent,for cases of hp≤0.40 m the smoke could propagate through the whole tunnel without backflow,while for cases of hp>0.40 m,the backflow exists and the smoke movement can be separated into three periods(propagation,stagnation,and retraction).The critical criterion of backflow was investigated and a simple model was deduced to estimate the maximum propagation length.Moreover,the dimensionless time for the smoke flow to reach its maximum propagation length was established.Finally,a comprehensive index was proposed to evaluate the synergistic effects of smoke extraction and control performance.These studies may provide positive significance for the ventilation design. 展开更多
关键词 Tunnel fire smoke extraction smoke control Ventilation shafts Transient propagation
在线阅读 下载PDF
高层建筑暖通空调防排烟施工技术的应用策略分析
11
作者 李江 《中国厨卫》 2025年第11期277-279,共3页
随着高层建筑数量激增,暖通空调防排烟系统的施工质量直接关系到建筑的使用安全。基于此,文章对某高层商业综合体项目进行实地研究,对防排烟系统施工技术要点进行系统分析,结合工程实践验证,提出优化施工工艺与质量控制体系等应用策略... 随着高层建筑数量激增,暖通空调防排烟系统的施工质量直接关系到建筑的使用安全。基于此,文章对某高层商业综合体项目进行实地研究,对防排烟系统施工技术要点进行系统分析,结合工程实践验证,提出优化施工工艺与质量控制体系等应用策略。工程实践结果表明,优化后的施工技术方案使系统漏风率降低36%,风机振动值降低45%,系统启动时间缩短25%,显著提高了防排烟系统的可靠性和安全性,为同类工程提供参考依据。 展开更多
关键词 高层建筑 暖通空调 防排烟系统 施工技术
在线阅读 下载PDF
地下空间通风与防排烟系统设计及性能评估
12
作者 刘乾嵘 王勇宏 郝阳 《机电产品开发与创新》 2025年第5期182-184,共3页
本文围绕地下空间通风与防排烟系统的三个关键方面展开了论述,先探讨了地下空间通风系统的设计原则与策略,然后详细分析了地下空间防排烟系统的设计,最后对地下空间通风与防排烟系统的性能进行了综合评估,旨在进一步确保这些系统在设计... 本文围绕地下空间通风与防排烟系统的三个关键方面展开了论述,先探讨了地下空间通风系统的设计原则与策略,然后详细分析了地下空间防排烟系统的设计,最后对地下空间通风与防排烟系统的性能进行了综合评估,旨在进一步确保这些系统在设计和实际应用中均能达到预期的安全与舒适标准。 展开更多
关键词 地下空间 通风与防排烟 系统设计
在线阅读 下载PDF
烟气管理系统在邮轮上的应用探讨
13
作者 曾伟 万小三 +1 位作者 裴洋洋 谭欣静 《广东造船》 2025年第4期28-31,共4页
邮轮舱室多,通道狭窄密集,内部有大量可燃物,具有很大的火灾风险;同时,人员密度大,逃生路线长,火灾烟气的蔓延增加了疏散的难度,控制火灾烟气是降低邮轮火灾危害的重要手段之一。本文通过梳理法规规范对邮轮烟气管理系统的相关规定,分... 邮轮舱室多,通道狭窄密集,内部有大量可燃物,具有很大的火灾风险;同时,人员密度大,逃生路线长,火灾烟气的蔓延增加了疏散的难度,控制火灾烟气是降低邮轮火灾危害的重要手段之一。本文通过梳理法规规范对邮轮烟气管理系统的相关规定,分析不同处所的烟气控制需求,重点对逃生梯道、内走廊、高大空间及扁平大空间等区域进行分析研究,提出了相应的烟气控制措施。 展开更多
关键词 邮轮 火灾烟气 烟气管理系统 控制烟气蔓延
在线阅读 下载PDF
高层工业建筑排烟系统设计问题研究——以苏州吴中数字经济终端产品研发制造基地厂房为例
14
作者 丁格菲 徐刚 关瑾 《北方建筑》 2025年第1期23-26,共4页
随着城市用地成本的不断攀升,国内出现了大量高层工业建筑。本研究以苏州吴中数字经济终端产品研发制造基地厂房为例,探讨现行工业建筑排烟系统设计规范在高层工业建筑防排烟系统设计实践中的适用情况,分析了高层工业建筑中工业流程、... 随着城市用地成本的不断攀升,国内出现了大量高层工业建筑。本研究以苏州吴中数字经济终端产品研发制造基地厂房为例,探讨现行工业建筑排烟系统设计规范在高层工业建筑防排烟系统设计实践中的适用情况,分析了高层工业建筑中工业流程、排烟系统竖向分区及排烟口与防烟分区最远点水平距离三个具体设计问题,同时,针对上述三个具体设计问题提出了建设性的建议,以便为类似工程提供参考。 展开更多
关键词 高层工业建筑 排烟系统 防烟分区 竖向分区 排烟口
在线阅读 下载PDF
岛式地铁车站站台层火灾烟气控制方案研究
15
作者 肖杰 张伟 《暖通空调》 2025年第9期145-150,共6页
在某岛式地铁车站热烟测试中发现,先启动站台排烟系统、2 min后手动打开站台门启动隧道风机联合排烟的站台烟气控制方案,将会导致烟气大范围沉降,站台能见度降低,威胁疏散人员安全。本文通过数值模拟,提出了3种站台烟气控制方案,分析了... 在某岛式地铁车站热烟测试中发现,先启动站台排烟系统、2 min后手动打开站台门启动隧道风机联合排烟的站台烟气控制方案,将会导致烟气大范围沉降,站台能见度降低,威胁疏散人员安全。本文通过数值模拟,提出了3种站台烟气控制方案,分析了烟气蔓延过程、温度分布、CO浓度分布及能见度。研究发现:在保证下行风速满足的情况下,采用在站台门上方轨顶排热风道设置侧排烟口、利用车站隧道排热风机和站台排烟系统联合排烟的烟气控制方案效果最佳;而采用开启站台门两侧首尾滑动门、启动隧道风机与站台排烟系统联合排烟的烟气控制方案,以及采用开启靠近火源侧站台门、启动隧道风机与站台排烟系统联合排烟的烟气控制方案,在开启站台门后40~50 s左右,站台能见度将不能达到人员安全疏散的要求;对于已建成投运、采用开启靠近火源侧站台门、启动隧道风机与站台排烟系统联合排烟的烟气控制方案的车站,可在满足最小清晰高度的情况下,适当加深储烟仓厚度,同时应严格把握手动打开站台门、启动隧道风机辅助排烟的时间。 展开更多
关键词 岛式地铁车站 站台 火灾 烟气控制 隧道风机 排烟系统 热烟测试
在线阅读 下载PDF
防排烟镀锌风管安装质量提升策略研究
16
作者 耿玲玲 《广州建筑》 2025年第6期54-57,共4页
本研究以通风与空调安装工程现状为切入点,针对防排烟镀锌风管安装质量提升展开系统性研究。研究紧密结合工程实际案例,依据国家相关标准规范,从施工准备阶段的材料采购、结构设计、人员配置、工艺规划等环节入手,贯穿安装过程的全流程... 本研究以通风与空调安装工程现状为切入点,针对防排烟镀锌风管安装质量提升展开系统性研究。研究紧密结合工程实际案例,依据国家相关标准规范,从施工准备阶段的材料采购、结构设计、人员配置、工艺规划等环节入手,贯穿安装过程的全流程控制,延伸至质量检测与验收阶段,构建了一套具有针对性与科学性的质量提升体系。防排烟镀锌风管防火包覆安装施工技术的创新应用,有效解决了传统通风空调安装中存在的施工效率低下、安装精度不足、材料损耗过高等突出问题。该技术通过工艺革新,显著提升了施工效率与工程质量,降低了施工人员劳动强度及材料消耗,兼具显著的社会效益与经济价值。实施上述策略的核心目标是确保防排烟镀锌风管系统在火灾等紧急工况下,能够及时、高效地完成烟雾排出任务,稳定履行防烟与排烟功能,为保障人员生命财产安全及建筑物消防安全提供坚实的技术保障与质量支撑。 展开更多
关键词 防排烟系统 风管连接 材料质量 施工工艺 包覆安装 质量检测
在线阅读 下载PDF
基于PLC的仓库温湿度智能控制与烟雾报警系统设计
17
作者 孙闻成 《现代工程科技》 2025年第4期29-32,共4页
随着现代仓储业的蓬勃发展,仓库环境的精准控制对于货物的存储质量和安全保障愈发关键。详细阐述了一种基于可编程逻辑控制器(programmable logic controller,PLC)的仓库温湿度智能控制与烟雾报警系统设计方案。通过对系统方案设计、硬... 随着现代仓储业的蓬勃发展,仓库环境的精准控制对于货物的存储质量和安全保障愈发关键。详细阐述了一种基于可编程逻辑控制器(programmable logic controller,PLC)的仓库温湿度智能控制与烟雾报警系统设计方案。通过对系统方案设计、硬件设计、程序流程设计等方面的深入探讨,展示了该系统如何实现对仓库温湿度的精确调控以及对烟雾隐患的及时报警,有效提升了仓储环境的智能化管理水平,为仓储行业的高效、安全运营提供了有力支持。 展开更多
关键词 PLC 仓库温湿度控制 烟雾报警 智能系统
在线阅读 下载PDF
半横向排烟模式下PID控制反馈目标温度对烟气层吸穿的影响
18
作者 张宇轩 朱宏儒 +3 位作者 陈寅楠 刘春祥 余龙星 黄萍 《中南大学学报(自然科学版)》 北大核心 2025年第5期2017-2029,共13页
排烟系统对控制火灾烟气和减少人员伤亡至关重要。排烟口烟气层吸穿会降低排烟效率,影响烟气控制效果。为实时调整排烟风速避免烟气层吸穿,本文引入PID自动控制方法以实现智能排烟。首先,在验证了当前数值模拟结果可靠性的基础上对比了... 排烟系统对控制火灾烟气和减少人员伤亡至关重要。排烟口烟气层吸穿会降低排烟效率,影响烟气控制效果。为实时调整排烟风速避免烟气层吸穿,本文引入PID自动控制方法以实现智能排烟。首先,在验证了当前数值模拟结果可靠性的基础上对比了传统定风速排烟与PID控制排烟的烟气控制效果,证明了基于PID自动控制防吸穿方法的可行性。然后,通过改变火源功率、火源与排烟口间距及隧道截面尺寸等条件,系统研究了不同PID控制反馈点目标温度对烟气层吸穿的影响。最后,提出了PID控制临界吸穿反馈目标温度计算方法,发现临界吸穿温度系数K_(c)为4.7,通过与临界吸穿Froude数的对比,验证了临界吸穿反馈目标温度计算方法的普适性。 展开更多
关键词 PID控制系统 吸穿现象 半横向排烟 智能排烟
在线阅读 下载PDF
中庭防排烟系统性能化设计 被引量:14
19
作者 李思成 杜红 《暖通空调》 北大核心 2003年第4期71-74,共4页
阐述了中庭防排烟系统性能化设计的一般过程 ,详细分析了各个设计步骤 ,对重要的设计参数如烟层高度 ,能克服分层的最小火灾规模 ,烟层温度 ,不同类型烟羽流的质量生成率、排烟量、排烟口个数和排烟面积进行了量化。
关键词 中庭 防排烟系统 火灾 性能化设计 消防工程学 灭火
在线阅读 下载PDF
回廊式超高中庭排烟探讨 被引量:8
20
作者 刘明非 王泽宇 +3 位作者 张国昊 雷波 袁中原 李颖臻 《制冷与空调(四川)》 2013年第1期10-17,共8页
针对回廊式超高中庭,以地处巴基斯坦项目为例,采用火灾动力学数值模拟软件FDS(Fire Dynamics Simulation)对中庭火灾场景进行模拟,模拟内容包括火灾温度场、CO浓度场分布、能见度分布等,通过对烟气蔓延特性的分析和判断,得出优化的回廊... 针对回廊式超高中庭,以地处巴基斯坦项目为例,采用火灾动力学数值模拟软件FDS(Fire Dynamics Simulation)对中庭火灾场景进行模拟,模拟内容包括火灾温度场、CO浓度场分布、能见度分布等,通过对烟气蔓延特性的分析和判断,得出优化的回廊式超高中庭排烟系统设计。 展开更多
关键词 回廊式超高中庭 数值模拟 机械排烟