At present, DL/T 645-2007 communication protocol is used to collect data for smart meters. However, in the beginning, this protocol is not designed to be a secure protocol and only the function and reliability were ta...At present, DL/T 645-2007 communication protocol is used to collect data for smart meters. However, in the beginning, this protocol is not designed to be a secure protocol and only the function and reliability were taken into account. Plaintext is used in the protocol for data transmission, as a result, attackers can easily sniff the information and cause information leakage. In this paper, man-in-the-middle attack was used to verify that the smart meter data acquisition process was vulnerable when facing third-party attacks, and this can result in data eavesdropping. In order to resist such risks and prevent information being eavesdropped, a real ammeter communication experimental environment was built, it realized two-way identity authentication between data acquisition center and ammeter data center. At the same time, RSA (Rivest-Shamir-Adleman) was used to encrypt the meter data, which encrypted the collection, storage process of meter data and ensured the confidentiality and integrity of the meter data transmission. Compared with other methods, this method had obvious advantages. The analysis showed that this method can effectively prevent the data of smart meters from being eavesdropped.展开更多
The storage space and cost for Smart Grid datasets has been growing exponentially due to its high data-rate of various sensor readings from Automated Metering Infrastructure (AMI), and Phasor Measurement Units (PMUs)....The storage space and cost for Smart Grid datasets has been growing exponentially due to its high data-rate of various sensor readings from Automated Metering Infrastructure (AMI), and Phasor Measurement Units (PMUs). The paper focuses on Phasor Data Concentrators (PDCs) that aggregate data from PMUs. PMUs measure real-time voltage, current and frequency parameters across the electrical grid. A typical PDC can process data from anywhere ten to forty PMUs. The paper exploits the need for appropriate security and data compression challenges simultaneously. As a result, an optimal compression method ER1c is investigated for efficient storage of IREG and C37.118 timestamped PDC data sets. We expect that our approach can greatly reduce the storage cost requirements of commercial available PDCs (SEL 3373, GE Multilin P30) by 80%. For example, 2 years of PDC data storage space can be easily replaced with only 10 days of storage space. In addition, our approach in combination with AES 256 encryption can protect PDC data to larger degree as per National Institute of Standards and Technology (NIST) standards.展开更多
文摘At present, DL/T 645-2007 communication protocol is used to collect data for smart meters. However, in the beginning, this protocol is not designed to be a secure protocol and only the function and reliability were taken into account. Plaintext is used in the protocol for data transmission, as a result, attackers can easily sniff the information and cause information leakage. In this paper, man-in-the-middle attack was used to verify that the smart meter data acquisition process was vulnerable when facing third-party attacks, and this can result in data eavesdropping. In order to resist such risks and prevent information being eavesdropped, a real ammeter communication experimental environment was built, it realized two-way identity authentication between data acquisition center and ammeter data center. At the same time, RSA (Rivest-Shamir-Adleman) was used to encrypt the meter data, which encrypted the collection, storage process of meter data and ensured the confidentiality and integrity of the meter data transmission. Compared with other methods, this method had obvious advantages. The analysis showed that this method can effectively prevent the data of smart meters from being eavesdropped.
文摘The storage space and cost for Smart Grid datasets has been growing exponentially due to its high data-rate of various sensor readings from Automated Metering Infrastructure (AMI), and Phasor Measurement Units (PMUs). The paper focuses on Phasor Data Concentrators (PDCs) that aggregate data from PMUs. PMUs measure real-time voltage, current and frequency parameters across the electrical grid. A typical PDC can process data from anywhere ten to forty PMUs. The paper exploits the need for appropriate security and data compression challenges simultaneously. As a result, an optimal compression method ER1c is investigated for efficient storage of IREG and C37.118 timestamped PDC data sets. We expect that our approach can greatly reduce the storage cost requirements of commercial available PDCs (SEL 3373, GE Multilin P30) by 80%. For example, 2 years of PDC data storage space can be easily replaced with only 10 days of storage space. In addition, our approach in combination with AES 256 encryption can protect PDC data to larger degree as per National Institute of Standards and Technology (NIST) standards.