High-entropy oxides(HEOs)have sparked scientific interest recently as a potential material technology for lithium-sulfur(Li–S)batteries.This interest stems from their simultaneous roles as sulfur hosts and electrocat...High-entropy oxides(HEOs)have sparked scientific interest recently as a potential material technology for lithium-sulfur(Li–S)batteries.This interest stems from their simultaneous roles as sulfur hosts and electrocatalysts,which provide enhancements to the performance of sulfur cathode composites.Nonetheless,their incorporation into the active material blend results in compromised energy density,particularly when their gravimetric proportion is substantial(≥10 wt.%,in the sulfur-based cathode).展开更多
Due to the wide and adjustable emission range,Ce^(3+)is an indispensable luminous center for full spectrum lighting.However,it needs to be sintered at high temperature in a reducing atmosphere,resulting in difficulty ...Due to the wide and adjustable emission range,Ce^(3+)is an indispensable luminous center for full spectrum lighting.However,it needs to be sintered at high temperature in a reducing atmosphere,resulting in difficulty to coexisting with other multivalent activated ions(such as Eu^(3+),Tm^(3+)),which greatly hinders the formation of full spectrum.In this study,a calcium vacancy enhanced self-reduction of Ce^(4+)is realized in CaNaSb_(2)O_(6)F(CNSOF)host under air atmosphere sintering,through which Ce^(3+),Tm^(3+)and Eu^(3+)coexisting in a single-phase full spectrum phosphor was prepared.Notably,the artificial introduction of a calcium vacancy was designed to verify this self-reduction mechanism.Moreover,the energy transfer kinetics among Tm^(3+),Ce^(3+)and Eu^(3+)were explored.Finally,combined with a 340 nm UV chip,a full spectrum phosphor-converted light-emitting diode(pc-LED)was fabricated,showing a broad emission range from 400 to 750 nm,Commission Internationale de I'Edairage(CIE)of(0.3485,0.3673),Ra of 92 and correlated color temperature(CCT)of 4933 K.Utilizing the variation in emission colors of this phosphor under different UV wavelengths,a dual encryption method combining point character code and fluorescent encryption technique is proposed.This work provides an effective path for Ce^(4+)self-reduction to apply in full spectrum pc-LED and information encryption.展开更多
In contemporary medium-voltage distribution networks heavily penetrated by distributed energy resources(DERs),the harmonic components injected by power-electronic interfacing converters,together with the inherently in...In contemporary medium-voltage distribution networks heavily penetrated by distributed energy resources(DERs),the harmonic components injected by power-electronic interfacing converters,together with the inherently intermittent output of renewable generation,distort the zero-sequence current and continuously reshape its frequency spectrum.As a result,single-line-to-ground(SLG)faults exhibit a pronounced,strongly non-stationary behaviour that varies with operating point,load mix and DER dispatch.Under such circumstances the performance of traditional rule-based algorithms—or methods that rely solely on steady-state frequency-domain indicators—degrades sharply,and they no longer satisfy the accuracy and universality required by practical protection systems.To overcome these shortcomings,the present study develops an SLG-fault identification scheme that transforms the zero-sequence currentwaveforminto two-dimensional image representations and processes themwith a convolutional neural network(CNN).First,the causes of sample-distribution imbalance are analysed in detail by considering different neutralgrounding configurations,fault-inception mechanisms and the statistical probability of fault occurrence on each phase.Building on these insights,a discriminator network incorporating a Convolutional Block Attention Module(CBAM)is designed to autonomously extract multi-layer spatial-spectral features,while Gradient-weighted Class Activation Mapping(Grad-CAM)is employed to visualise the contribution of every salient image region,thereby enhancing interpretability.A comprehensive simulation platform is subsequently established for a DER-rich distribution system encompassing several representative topologies,feeder lengths and DER penetration levels.Large numbers of realistic SLG-fault scenarios are generated—including noise and measurement uncertainty—and are used to train,validate and test the proposed model.Extensive simulation campaigns,corroborated by field measurements from an actual utility network,demonstrate that the proposed approach attains an SLG-fault identification accuracy approaching 100 percent and maintains robust performance under severe noise conditions,confirming its suitability for real-world engineering applications.展开更多
In order to increase the stability of the Mongolia power system, a single-phase automatic reclosing device (SPAR) was introduced on double-circuit power lines built with a size of 330 kV, operating on a voltage of 220...In order to increase the stability of the Mongolia power system, a single-phase automatic reclosing device (SPAR) was introduced on double-circuit power lines built with a size of 330 kV, operating on a voltage of 220 kV and a length of 250 km. These overhead power lines (L-213, L-214) connect the 220/110/35 kV “Songino” substation with the “Mandal” substation and form system networks. This paper presents the challenges encountered when implementing single-phase automatic reclosing (SPAR) devices and compares the changes in power system parameters before and after SPAR deployment for a long 220 kV line. Simulations and analyses were carried out using DIgSILENT PowerFactory software, focusing on rotor angle stability, and the overall impact on the power system during short-circuit faults. The evaluation also utilized measurement data from the Wide Area Monitoring System (WAMS) to compare system behavior pre- and post-implementation of SPAR. The findings reveal that SPAR significantly enhances system reliability and stability, effectively mitigating the risk of oscillations and stability loss triggered by short circuits. This improvement contributes to a more resilient power system, reducing the potential for disturbances caused by faults.展开更多
In the present study,a body-centered-cubic(BCC)structured Nb/TiNb multilayer nanocomposite with high yield strength,which comprises a soft TiNb matrix and reinforced Nb nanowires,was designed and fabricated with the a...In the present study,a body-centered-cubic(BCC)structured Nb/TiNb multilayer nanocomposite with high yield strength,which comprises a soft TiNb matrix and reinforced Nb nanowires,was designed and fabricated with the aim of elucidating the strengthening mechanism of Nb/TiNb multilayer nanocomposite by scanning electron microscope,transmission electron microscopy and in situ synchrotron X-ray diffraction.It is observed that the Nb/TiNb nanocomposite possesses a high yield strength of~640 MPa,significantly exceeding that of the conventional single-phaseβ-type Ti alloys.Further experimental results indicate that as plastic deformation commenced in the TiNb matrix of Nb/TiNb nanocomposite,load transfer from the soft TiNb matrix into the reinforced Nb nanowires occurred,allowing for a high load-bearing stress contribution and a significant strength enhancement of Nb/TiNb nanocomposite.Meanwhile,the embedded Nb nanowires can effectively impede the propagation of dislocation in TiNb matrix,further strengthening the present nanocomposite.These findings elucidate the strengthening mechanism of Nb/TiNb nanocomposite through the above two combinations,providing a basis for the design and development of the high-strength composites with a single-phase BCC structure for biomedical applications.展开更多
Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication ...Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication infrastructure for LFC increases the risk of being attacked by malicious actors.The dynamic load altering attack(DLAA)is a typical attack that can destabilize the power system,causing the grid frequency to deviate fromits nominal value.Therefore,in this paper,we mathematically analyze the impact of DLAA on the stability of the grid frequency and propose the network parameter regulation(NPR)to mitigate the impact.To begin with,the dynamic LFC model is constructed by highlighting the importance of the network parameter.Then,we model the DLAA and analyze its impact on LFC using the theory of second-order dynamic systems.Finally,we model the NPR and prove its effect in mitigating the DLAA.Besides,we construct a least-effort NPR considering its infrastructure cost and aim to reduce the operation cost.Finally,we carry out extensive simulations to demonstrate the impact of the DLAA and evaluate the mitigation performance of NPR.The proposed cost-benefit NPR approach can not only mitigate the impact of DLAA with 100%and also save 41.18$/MWh in terms of the operation cost.展开更多
This paper studies the structural response of high-speed train wipers under the combined action of complex flow fields and scraping actions.The stress concentration areas are determined through simulation analysis,and...This paper studies the structural response of high-speed train wipers under the combined action of complex flow fields and scraping actions.The stress concentration areas are determined through simulation analysis,and the stress and aerodynamic load measurement points are reasonably arranged accordingly.The actual measurement is carried out in combination with the operating conditions of the existing lines.The stress variations and spectral characteristics of the train under different speed levels(80,160,180,200 km/h),tunnel entry and exit,and scraper action conditions were compared and analyzed.The stress amplification factors under tunnel intersection and scraper action were obtained,providing boundary conditions for the design of wipers for highspeed s.The research results show that the maximum stress of the wiper structure obtained through simulation calculation is concentrated at the connection of the wiper arm.Structural stress increases with the rise of speed grade.The stress increases by 1.11 times when the tunnel meets.When the scraper operates,the stress on the scraper arm increases by 4.1–7.6 times.Due to the broadband excitation effect of the aerodynamic load,the spectral energy of the structure is relatively high at the natural frequency,which excites the natural mode of the wiper.展开更多
Studies of wave-current interactions are vital for the safe design of structures.Regular waves in the presence of uniform,linear shear,and quadratic shear currents are explored by the High-Level Green-Naghdi model in ...Studies of wave-current interactions are vital for the safe design of structures.Regular waves in the presence of uniform,linear shear,and quadratic shear currents are explored by the High-Level Green-Naghdi model in this paper.The five-point central difference method is used for spatial discretization,and the fourth-order Adams predictor-corrector scheme is employed for marching in time.The domain-decomposition method is applied for the wave-current generation and absorption.The effects of currents on the wave profile and velocity field are examined under two conditions:the same velocity of currents at the still-water level and the constant flow volume of currents.Wave profiles and velocity fields demonstrate substantial differences in three types of currents owing to the diverse vertical distribution of current velocity and vorticity.Then,loads on small-scale vertical cylinders subjected to regular waves and three types of background currents with the same flow volume are investigated.The maximum load intensity and load fluctuation amplitude in uniform,linear shear,and quadratic shear currents increase sequentially.The stretched superposition method overestimates the maximum load intensity and load fluctuation amplitude in opposing currents and underestimates these values in following currents.The stretched superposition method obtains a poor approximation for strong nonlinear waves,particularly in the case of the opposing quadratic shear current.展开更多
Data center industries have been facing huge energy challenges due to escalating power consumption and associated carbon emissions.In the context of carbon neutrality,the integration of data centers with renewable ene...Data center industries have been facing huge energy challenges due to escalating power consumption and associated carbon emissions.In the context of carbon neutrality,the integration of data centers with renewable energy has become a prevailing trend.To advance the renewable energy integration in data centers,it is imperative to thoroughly explore the data centers’operational flexibility.Computing workloads and refrigeration systems are recognized as two promising flexible resources for power regulationwithin data centermicro-grids.This paper identifies and categorizes delay-tolerant computing workloads into three types(long-running non-interruptible,long-running interruptible,and short-running)and develops mathematical time-shifting models for each.Additionally,this paper examines the thermal dynamics of the computer room and derives a time-varying temperature model coupled to refrigeration power.Building on these models,this paper proposes a two-stage,multi-time scale optimization scheduling framework that jointly coordinates computing workloads time-shift in day-ahead scheduling and refrigeration power control in intra-day dispatch to mitigate renewable variability.A case study demonstrates that the framework effectively enhances the renewable-energy utilization,improves the operational economy of the data center microgrid,and mitigates the impact of renewable power uncertainty.The results highlight the potential of coordinated computing workloads and thermal system flexibility to support greener,more cost-effective data center operation.展开更多
Significant diurnal temperature variations in mountainous rack railways cause stiffness mismatches between the rack structure and simply supported bridges,leading to critical failures like bolt loosening and rack frac...Significant diurnal temperature variations in mountainous rack railways cause stiffness mismatches between the rack structure and simply supported bridges,leading to critical failures like bolt loosening and rack fractures.This study develops a dynamic model of the vehicle-rack-bridge system based on train-track-bridge interaction theory,integrating gear-rack meshing and wheel-rail contact mechanisms.The model analyzes the dynamic response of bridges with varying spans under combined thermal and dynamic loading.Numerical simulations,conducted using finite element analysis,reveal peak vibration accelerations of 1.3 m/s^(2)for the rack,3.0 m/s^(2)for the rail,1.2 m/s^(2)for the sleeper,and 0.1 m/s^(2)for the bridge,with maximum stresses of 3 MPa in the rack,8 MPa in the rail,and 25 MPa in connecting bolts.The results show significant span-dependent amplification of stress and strain in the rack system under thermo-mechanical loading,exceeding material strength limits at 60-meter spans.An innovative elastic connection method is proposed to mitigate stress concentrations effectively,en-hancing system durability.This study introduces a novel approach to modeling complex thermo-mechanical interactions in rack railway systems,validated through extensive simulations,and provides a practical solution for improving structural resilience,offering theoretical guidance for optimizing rack-bridge system design to ensure operational safety in extreme environmental conditions.展开更多
The multi-pass intermittent local loading process,which features a more flexible processing path,can further enhance the second material distribution during local loading,improve the formability of components,and redu...The multi-pass intermittent local loading process,which features a more flexible processing path,can further enhance the second material distribution during local loading,improve the formability of components,and reduce forming loads.However,the absence of compatible forming equipment makes it difficult to control the constraint in the unloaded zones during the forming process.This difficulty complicates coordination and control of deformation,particularly for asymmetric rib-web components.Additionally,the current implementation involves multi-fire heating,a long process flow,and high energy consumption,which limits the popularization and application of the local loading process.In this study,a new multi-pass local loading hydraulic forming apparatus that can quickly and reliably switch between heavy-load deformation and low-load constraint for different local loading sub-dies was developed.A 10-tonne laboratory prototype was developed,and the forming characteristics during the forming process as well as the response characteristics of the hydraulic system during the multi-pass intermittent local loading of rib-web component were investigated using numerical simulations and physical experiments.Results indicated that,compared to a whole loading process with the same initial geometry of billet,the total forming load(i.e.,the sum of loaded and restrained loads)is reduced by more than 40%with the local loading process,and by nearly 50%with multi-pass local loading.The multi-pass local loading process allows for more effective control of material flow compared to single-pass local loading,leading to improved cavity filling and reduced flow line disturbance.For a large-scale,complex titanium alloy bulkhead,the cavity filling problem was addressed by optimizing the multi-pass local loading path with an unequal thickness billet.The dynamic performance of the multi-pass local loading hydraulic system was found to be robust,with stable pressure transitions during motion and load switching for the sub-die(s).The dynamic characteristic of the hydraulic cylinder when switching from non-moving/unloaded state to a moving/loading state are consistent whether a load is present or not.However,the dynamic characteristics differ when switching from a moving/loading state to non-moving/unloaded state,showing opposite behavior.The developed hydraulic drive mechanism provides a way for implementation of multi-pass local loading without auxiliary operation and extra heating.The results of the study provide a foundation for the industrial production of large-scale,complex components with reduced force requirement and low-energy consumption.展开更多
Unbonded post-tensioned(PT)concrete systems are widely used in safety-critical structures,yet model-ing practices for prestress implementation and tendon-concrete interaction remain inconsistent.This study investigate...Unbonded post-tensioned(PT)concrete systems are widely used in safety-critical structures,yet model-ing practices for prestress implementation and tendon-concrete interaction remain inconsistent.This study investigates the effects of sheath(duct)implementation and confinement assumptions through nonlinear finite element analysis.Four modeling cases were defined,consisting of an explicit sheath without tendon-concrete confinement(S)and three no-sheath variants with different confinement levels(X,N,A).One-way beams and two-way panels were analyzed,and panel blast responses were validated against experimental results.In both beams and panels,average initial stress levels were similar across models,through local stress concentrations appeared when the sheath was modeled.Under blast loading,these local effects became critical,and the sheath-implemented model reproduced experimental behavior most accurately,whereas non-implemented models deviated.Reduced blast intensity diminished the differences among models,thereby reaffirming that sheath-induced localization and damage propagation are critical factors.These findings highlight the importance of explicit sheath implementation for realistic numerical assessment of unbonded PT structures under extreme loads.展开更多
Air conditioning is a major energy-consuming component in buildings,and accurate air conditioning load forecasting is of great significance for maximizing energy utilization efficiency.However,the deep learning models...Air conditioning is a major energy-consuming component in buildings,and accurate air conditioning load forecasting is of great significance for maximizing energy utilization efficiency.However,the deep learning models currently used in the field of air conditioning load forecasting often suffer from issues such as distribution bias in load data and insufficient expression ability of nonlinear features in the model,which affect the accuracy of load forecasting.To address this,this paper proposes a novel load forecasting model.Firstly,the model employs the Dish-TS(DS)module to standardize the input window data through self-learning standardized parameters,thereby addressing the spatial intra-bias problem existing between data.Secondly,DS-Kansformer introduces Kolmogorov-Arnold Networks(KANs)to enhance the expression ability of nonlinear features.Finally,the output window is denormalized through the self-learning parameter of the DS module to restore the original distribution of the predicted data.In this paper,experiments were carried out based on the air-conditioning load dataset collected from a multi-functional comprehensive building,and the experimental results show that after adding the DS module,the Mean Absolute Error(MAE),Root Mean Square Error(RMSE),and R-squared(R^(2))of the model are 20.46%,34.44%,and 92.61%,respectively;after introducing KAN,the MAE,RMSE,and R^(2) are 22.81%,35.72%,and 92.05%,respectively;the model also exhibits high prediction accuracy after integrating the two modules(with RMSE,MAE,and R^(2) being 19.75%,34.05%,and 92.78%,respectively),outperforming common time series prediction models,confirming the reliability and efficiency of the model,which can provide reliable support for intelligent energy management in buildings.展开更多
This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater pene...This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater penetration,power grids are becoming increasingly vulnerable to cyber threats,potentially leading to frequency instability and widespread disruptions.We model two significant attack vectors:load-altering attacks(LAAs)and false data injection attacks(FDIAs)that corrupt frequency measurements.These are analyzed for their impact on grid frequency stability in both linear and nonlinear LFC models,incorporating generation rate constraints and nonlinear loads.A coordinated attack strategy is presented,combining LAAs and FDIAs to achieve stealthiness by concealing frequency deviations from system operators,thereby maximizing disruption while evading traditional detection.To counteract these threats,we propose an Unknown Input Observer(UIO)-based detection framework for linear and nonlinear LFCs.The UIO is designed using linear matrix inequalities(LMIs)to estimate system states while isolating unknown attack inputs,enabling attack detection through monitoring measurement residuals against a predefined threshold.For mitigation,we leverage BESS capabilities with two adaptive strategies:dynamic mitigation for dynamic LAAs,which tunes BESS parameters to enhance the system’s stability margin and accelerate convergence to equilibrium;and staticmitigation for static LAAs and FDIAs.Simulations show that the UIO achieves high detection accuracy,with residuals exceeding thresholds promptly under coordinated attacks,even in nonlinear models.Mitigation strategies reduce frequency deviations by up to 80%compared to unmitigated cases,restoring stability within seconds.展开更多
With the growing global demand for energy,deep underground salt caverns are emerging as a potential solution for large-scale energy storage.In this study,multistage cyclic loading tests were conducted on rock salt at ...With the growing global demand for energy,deep underground salt caverns are emerging as a potential solution for large-scale energy storage.In this study,multistage cyclic loading tests were conducted on rock salt at different temperatures in combination with real-time acoustic emission(AE)monitoring.The results show that the cumulative AE count increases stepwise with increasing cyclic stress.The peak frequency is concentrated primarily in the medium-frequency range,exhibiting a band distribution across low-,medium-,and high-frequency ranges.As the temperature increases,the proportion of low-frequency signals decreases from 14.32%to 5.76%,whereas the proportion of medium-frequency signals increases from 85.48%to 94.1%.The proportion of high-frequency signals remains relatively constant between 0.1%and 0.2%.The amplitude-count relationship of the AE signals demonstrates a strong negative power-law correlation.Furthermore,with increasing temperature,the negative power-law exponent of the amplitude gradually decreases,with the b value decreasing from 1.096 to 0.837 and the a value decreasing from 7.4871 to 6.6982.Under all four temperature conditions,the dominant failure mode in rock salt is tensile cracking.However,as the temperature increases,the proportion of tensile cracks decreases from 88.59%to 75.12%,whereas the proportion of shear cracks at 80℃is nearly double that at 20℃.This finding indicates that as the temperature increases,the ductility of the material increases,and the crack propagation mode shifts from tensile to shear.This research provides valuable insights for the design and stability assessment of salt cavern reservoirs for deep underground energy storage systems.展开更多
The automatic loading systems of artillery are critical for the accurate,efficient,and reliable delivery of pro-jectiles and propellants into the gun chamber.In modern artillery,the ammunition conveyor serves as the e...The automatic loading systems of artillery are critical for the accurate,efficient,and reliable delivery of pro-jectiles and propellants into the gun chamber.In modern artillery,the ammunition conveyor serves as the end effector of the automatic loading system,and its motion state significantly impacts the accuracy of projectiles.Therefore,it is of immense importance to precisely and effectively evaluate the reliability of the motion accuracy of the ammunition conveyor.This paper aims to propose a practical and efficient analysis method for evaluating the reliability of the motion accuracy of the ammunition conveyor.The proposed approach involves the use of a deep learning network to approximate the physical model and the extremum method to obtain a single cycle sequence decoupling strategy for solving the time-varying reliability issue of complex systems.Employing this strategy,the time-varying reliability of the ammunition conveyor is transformed into a static reliability problem.The proposed method includes the use of a deep feedforward neural network,second-order saddle point ap-proximation(SPA)method,extremum method,and efficient global optimization(EGO)technology.The results reveal that the reliability of the motion accuracy of the ammunition conveyor is 93.42%,with the maximum failure probability occurring at 0.21 s.These results serve as an important reference for the structural optimi-zation design of the ammunition conveyor based on reliability and the maintenance of the operational process.展开更多
Large-scale geological energy storage plays a crucial role in balancing the intermittency of renewable energy.As an energy storage medium,soaked sandstone has a wide range of applications in geological energy storage....Large-scale geological energy storage plays a crucial role in balancing the intermittency of renewable energy.As an energy storage medium,soaked sandstone has a wide range of applications in geological energy storage.Understanding the damage characteristics in soaked sandstones is essential for ensuring the stability and longevity of these energy storage systems.This study involved multi-stage cyclic loading tests conducted on soaked sandstone to explore the damage evolution throughout the loading process.The findingsreveal several important insights:(1)The plastic hysteresis loops observed during multi-stage cyclic loading evolved from dense to sparse.An increase in stress level led to greater damage in the rock,as evidenced by an increase in accumulated peak/plastic strains.(2)Energy density and stress level are related by quadratic polynomial relationships.The elastic and dissipated energy densities are related by a linear law.The average energy storage coefficientdecreased by up to 24.1%with increasing stress amplitude,reflectingchanges in energy dynamics within the samples.(3)AE counts,amplitude,and frequency provided critical insights into rock damage and fracture patterns.The greater the loading rate and stress amplitude,the lower the proportion of high-amplitude,high-peak frequency,and shear-type fractures.Increasing stress amplitude caused a maximum 16.63%reduction in the AE bvalue,indicating shifts in fracture behavior under varying stress conditions.(4)The increase in loading rate and stress amplitude promotes the transformation of micropores and mesopores to macropores/microcracks.(5)Damage variables,definedin terms of cumulative dissipation energy,aligned closely with the fatigue damage model under multi-stage cyclic loading.Accelerated damage primarily occurred during the finalstages of fatigue loading,highlighting critical periods in the degradation of soaked sandstones.This study can offer guidance for designing operational parameters for energy storage geological bodies dominated by soaked sandstones.展开更多
This study investigates the performance of high-strength cable bolts under impact loading conditions representative of rock bursts in underground environments.Although widely used,the dynamic behaviour of these cable ...This study investigates the performance of high-strength cable bolts under impact loading conditions representative of rock bursts in underground environments.Although widely used,the dynamic behaviour of these cable bolts has received limited experimental attention,and their effectiveness in seismically active zones remains a subject of ongoing debate.To address this gap,a reverse pull-out test machine integrated with a drop hammer rig was employed.Tests were conducted on 70-t SUMO bulbed and non-bulbed cable bolts with encapsulation lengths of 300 and 450 mm,subjected to an impact energy of 14.52 k J.Results indicate that non-bulbed cables,despite showing lower initial peak loads(average 218 vs.328 k N for bulbed cables at 300 mm encapsulation),demonstrated superior energy absorption(average 11.26 vs.8.75 k J)and displacement capacity(average 48.40 vs.36.25 mm).Increasing the encapsulation length for bulbed cables led to a reduction in initial peak load but improved displacement and energy absorption.The dominant failure mechanism was debonding at the cable-grout interface,characterised by frictional sliding and cable rotation.These findings provide new insights into the energy dissipation mechanisms of cables and support the development of more resilient ground support systems for dynamically active conditions.展开更多
Investigating effect of recrystallization mechanism on deformation mode and texture evolution is conducive to controlling deformation mechanism and texture in magnesium alloys under medium-high temperature impact load...Investigating effect of recrystallization mechanism on deformation mode and texture evolution is conducive to controlling deformation mechanism and texture in magnesium alloys under medium-high temperature impact loading.In the present study,a Johnson-Cook model incorporating twin strengthening was established to simulate macro-deformation,and a twinning induced recrystallization(TDRX)model and bulging recrystallization(GBBDRX)model are introduced into visco-plastic self consistant(VPSC)framework to quantitatively study the deformation mechanism of pre-twinned AZ31 magnesium alloy during medium-high temperature impact loading.Both TDRX and GBBDRX occur,with basal slip as the dominant slip system,followed by pyramidal〈c+a〉slip and prismatic slip.The dynamic recrystallization(DRX)significantly influences basal and pyramidal〈c+a〉slip systems,with minimal impact on secondary deformation mechanism.In addition,the recrystallization mechanism of grain boundary bowing increases the activity of basal slip and decreases the activity of pyramidal〈c+a〉slip.The nucleation and growth of recrystallized grains enhance basal slip activity and suppress pyramidal〈c+a〉slip,leading to the formation of a strong basal texture.As dynamic recrystallization progresses,a bimodal texture develops,characterized by a reduction in basal component pole density and a more pronounced basal slip.展开更多
This study establishes and validates a method for the precise quantification of aquatic microbial loads using microbial diversity absolute quantitative sequencing.By adding synthetic spike-in DNA to water samples from...This study establishes and validates a method for the precise quantification of aquatic microbial loads using microbial diversity absolute quantitative sequencing.By adding synthetic spike-in DNA to water samples from the Dahei River prior to DNA extraction and 16S rRNA gene sequencing,it generates standard curves to convert sequencing data into absolute microbial copy numbers.The method,which is proved highly accurate(R^(2)>0.99),reveals a clear contrast between the river sites:the upstream community has not only a significantly higher total microbial load but also a completely different makeup of species compared to the downstream site.This approach effectively overcomes the limitations of relative abundance analysis,providing a powerful tool for environmental monitoring,and proposes key steps for future standardization to ensure data comparability and integration.展开更多
基金financially supported by the National Natural Science Foundation of China(52372289 and 52102368)Guangdong Special Fund for Key Areas(20237DZX3042)+2 种基金State Key Laboratory of New Ceramic Materials Tsinghua University(No.KF202415)Shenzhen Stable Support Projectsupported by the Centre for Advances in Reliability and Safety(CAiRS)admitted under AIR@Inno HK Research Cluster and HK Poly U Postdoc Matching Fund Scheme(1-W28H)。
文摘High-entropy oxides(HEOs)have sparked scientific interest recently as a potential material technology for lithium-sulfur(Li–S)batteries.This interest stems from their simultaneous roles as sulfur hosts and electrocatalysts,which provide enhancements to the performance of sulfur cathode composites.Nonetheless,their incorporation into the active material blend results in compromised energy density,particularly when their gravimetric proportion is substantial(≥10 wt.%,in the sulfur-based cathode).
基金Project supported by National Natural Science Foundation of China(62075203,12304460)Zhejiang Provincial Natural Science Foundation of China(LQ23A040007)Basic Public Welfare Research Program of Zhejiang Province(LDT23F05013F05)。
文摘Due to the wide and adjustable emission range,Ce^(3+)is an indispensable luminous center for full spectrum lighting.However,it needs to be sintered at high temperature in a reducing atmosphere,resulting in difficulty to coexisting with other multivalent activated ions(such as Eu^(3+),Tm^(3+)),which greatly hinders the formation of full spectrum.In this study,a calcium vacancy enhanced self-reduction of Ce^(4+)is realized in CaNaSb_(2)O_(6)F(CNSOF)host under air atmosphere sintering,through which Ce^(3+),Tm^(3+)and Eu^(3+)coexisting in a single-phase full spectrum phosphor was prepared.Notably,the artificial introduction of a calcium vacancy was designed to verify this self-reduction mechanism.Moreover,the energy transfer kinetics among Tm^(3+),Ce^(3+)and Eu^(3+)were explored.Finally,combined with a 340 nm UV chip,a full spectrum phosphor-converted light-emitting diode(pc-LED)was fabricated,showing a broad emission range from 400 to 750 nm,Commission Internationale de I'Edairage(CIE)of(0.3485,0.3673),Ra of 92 and correlated color temperature(CCT)of 4933 K.Utilizing the variation in emission colors of this phosphor under different UV wavelengths,a dual encryption method combining point character code and fluorescent encryption technique is proposed.This work provides an effective path for Ce^(4+)self-reduction to apply in full spectrum pc-LED and information encryption.
基金supported by the Science and Technology Program of China Southern Power Grid(031800KC23120003).
文摘In contemporary medium-voltage distribution networks heavily penetrated by distributed energy resources(DERs),the harmonic components injected by power-electronic interfacing converters,together with the inherently intermittent output of renewable generation,distort the zero-sequence current and continuously reshape its frequency spectrum.As a result,single-line-to-ground(SLG)faults exhibit a pronounced,strongly non-stationary behaviour that varies with operating point,load mix and DER dispatch.Under such circumstances the performance of traditional rule-based algorithms—or methods that rely solely on steady-state frequency-domain indicators—degrades sharply,and they no longer satisfy the accuracy and universality required by practical protection systems.To overcome these shortcomings,the present study develops an SLG-fault identification scheme that transforms the zero-sequence currentwaveforminto two-dimensional image representations and processes themwith a convolutional neural network(CNN).First,the causes of sample-distribution imbalance are analysed in detail by considering different neutralgrounding configurations,fault-inception mechanisms and the statistical probability of fault occurrence on each phase.Building on these insights,a discriminator network incorporating a Convolutional Block Attention Module(CBAM)is designed to autonomously extract multi-layer spatial-spectral features,while Gradient-weighted Class Activation Mapping(Grad-CAM)is employed to visualise the contribution of every salient image region,thereby enhancing interpretability.A comprehensive simulation platform is subsequently established for a DER-rich distribution system encompassing several representative topologies,feeder lengths and DER penetration levels.Large numbers of realistic SLG-fault scenarios are generated—including noise and measurement uncertainty—and are used to train,validate and test the proposed model.Extensive simulation campaigns,corroborated by field measurements from an actual utility network,demonstrate that the proposed approach attains an SLG-fault identification accuracy approaching 100 percent and maintains robust performance under severe noise conditions,confirming its suitability for real-world engineering applications.
文摘In order to increase the stability of the Mongolia power system, a single-phase automatic reclosing device (SPAR) was introduced on double-circuit power lines built with a size of 330 kV, operating on a voltage of 220 kV and a length of 250 km. These overhead power lines (L-213, L-214) connect the 220/110/35 kV “Songino” substation with the “Mandal” substation and form system networks. This paper presents the challenges encountered when implementing single-phase automatic reclosing (SPAR) devices and compares the changes in power system parameters before and after SPAR deployment for a long 220 kV line. Simulations and analyses were carried out using DIgSILENT PowerFactory software, focusing on rotor angle stability, and the overall impact on the power system during short-circuit faults. The evaluation also utilized measurement data from the Wide Area Monitoring System (WAMS) to compare system behavior pre- and post-implementation of SPAR. The findings reveal that SPAR significantly enhances system reliability and stability, effectively mitigating the risk of oscillations and stability loss triggered by short circuits. This improvement contributes to a more resilient power system, reducing the potential for disturbances caused by faults.
基金supported by the National Natural Science Foundation of China(Nos.51771082,51971009 and 52175410)Zhenjiang Science and Technology Program(No.GY2020001)+2 种基金the Six Talent Peaks Project in Jiangsu Province(No.2019-XCL-113)the Project of Faculty of Agricultural Equipment of Jiangsu University(No.NZXB20200101)Advanced Photon Source,a US Department of Energy(DOE)Office of Science User Facility operated for the DOE Office of Science by Argonne National Laboratory under Contract No.DE-AC02-06CH11357.
文摘In the present study,a body-centered-cubic(BCC)structured Nb/TiNb multilayer nanocomposite with high yield strength,which comprises a soft TiNb matrix and reinforced Nb nanowires,was designed and fabricated with the aim of elucidating the strengthening mechanism of Nb/TiNb multilayer nanocomposite by scanning electron microscope,transmission electron microscopy and in situ synchrotron X-ray diffraction.It is observed that the Nb/TiNb nanocomposite possesses a high yield strength of~640 MPa,significantly exceeding that of the conventional single-phaseβ-type Ti alloys.Further experimental results indicate that as plastic deformation commenced in the TiNb matrix of Nb/TiNb nanocomposite,load transfer from the soft TiNb matrix into the reinforced Nb nanowires occurred,allowing for a high load-bearing stress contribution and a significant strength enhancement of Nb/TiNb nanocomposite.Meanwhile,the embedded Nb nanowires can effectively impede the propagation of dislocation in TiNb matrix,further strengthening the present nanocomposite.These findings elucidate the strengthening mechanism of Nb/TiNb nanocomposite through the above two combinations,providing a basis for the design and development of the high-strength composites with a single-phase BCC structure for biomedical applications.
基金supported by the project Major Scientific and Technological Special Project of Guizhou Province([2024]014).
文摘Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication infrastructure for LFC increases the risk of being attacked by malicious actors.The dynamic load altering attack(DLAA)is a typical attack that can destabilize the power system,causing the grid frequency to deviate fromits nominal value.Therefore,in this paper,we mathematically analyze the impact of DLAA on the stability of the grid frequency and propose the network parameter regulation(NPR)to mitigate the impact.To begin with,the dynamic LFC model is constructed by highlighting the importance of the network parameter.Then,we model the DLAA and analyze its impact on LFC using the theory of second-order dynamic systems.Finally,we model the NPR and prove its effect in mitigating the DLAA.Besides,we construct a least-effort NPR considering its infrastructure cost and aim to reduce the operation cost.Finally,we carry out extensive simulations to demonstrate the impact of the DLAA and evaluate the mitigation performance of NPR.The proposed cost-benefit NPR approach can not only mitigate the impact of DLAA with 100%and also save 41.18$/MWh in terms of the operation cost.
文摘This paper studies the structural response of high-speed train wipers under the combined action of complex flow fields and scraping actions.The stress concentration areas are determined through simulation analysis,and the stress and aerodynamic load measurement points are reasonably arranged accordingly.The actual measurement is carried out in combination with the operating conditions of the existing lines.The stress variations and spectral characteristics of the train under different speed levels(80,160,180,200 km/h),tunnel entry and exit,and scraper action conditions were compared and analyzed.The stress amplification factors under tunnel intersection and scraper action were obtained,providing boundary conditions for the design of wipers for highspeed s.The research results show that the maximum stress of the wiper structure obtained through simulation calculation is concentrated at the connection of the wiper arm.Structural stress increases with the rise of speed grade.The stress increases by 1.11 times when the tunnel meets.When the scraper operates,the stress on the scraper arm increases by 4.1–7.6 times.Due to the broadband excitation effect of the aerodynamic load,the spectral energy of the structure is relatively high at the natural frequency,which excites the natural mode of the wiper.
基金Supported by the Development and Application Project of Ship CAE Software.
文摘Studies of wave-current interactions are vital for the safe design of structures.Regular waves in the presence of uniform,linear shear,and quadratic shear currents are explored by the High-Level Green-Naghdi model in this paper.The five-point central difference method is used for spatial discretization,and the fourth-order Adams predictor-corrector scheme is employed for marching in time.The domain-decomposition method is applied for the wave-current generation and absorption.The effects of currents on the wave profile and velocity field are examined under two conditions:the same velocity of currents at the still-water level and the constant flow volume of currents.Wave profiles and velocity fields demonstrate substantial differences in three types of currents owing to the diverse vertical distribution of current velocity and vorticity.Then,loads on small-scale vertical cylinders subjected to regular waves and three types of background currents with the same flow volume are investigated.The maximum load intensity and load fluctuation amplitude in uniform,linear shear,and quadratic shear currents increase sequentially.The stretched superposition method overestimates the maximum load intensity and load fluctuation amplitude in opposing currents and underestimates these values in following currents.The stretched superposition method obtains a poor approximation for strong nonlinear waves,particularly in the case of the opposing quadratic shear current.
基金supported by Science and Technology Standard Project of Guangdong Electric Power Design Institute(ER11301W,ER11811W).
文摘Data center industries have been facing huge energy challenges due to escalating power consumption and associated carbon emissions.In the context of carbon neutrality,the integration of data centers with renewable energy has become a prevailing trend.To advance the renewable energy integration in data centers,it is imperative to thoroughly explore the data centers’operational flexibility.Computing workloads and refrigeration systems are recognized as two promising flexible resources for power regulationwithin data centermicro-grids.This paper identifies and categorizes delay-tolerant computing workloads into three types(long-running non-interruptible,long-running interruptible,and short-running)and develops mathematical time-shifting models for each.Additionally,this paper examines the thermal dynamics of the computer room and derives a time-varying temperature model coupled to refrigeration power.Building on these models,this paper proposes a two-stage,multi-time scale optimization scheduling framework that jointly coordinates computing workloads time-shift in day-ahead scheduling and refrigeration power control in intra-day dispatch to mitigate renewable variability.A case study demonstrates that the framework effectively enhances the renewable-energy utilization,improves the operational economy of the data center microgrid,and mitigates the impact of renewable power uncertainty.The results highlight the potential of coordinated computing workloads and thermal system flexibility to support greener,more cost-effective data center operation.
基金Supported by the Sichuan Science and Technology Program(Grant Nos.2021YFD0211,2023ZDZX0011).
文摘Significant diurnal temperature variations in mountainous rack railways cause stiffness mismatches between the rack structure and simply supported bridges,leading to critical failures like bolt loosening and rack fractures.This study develops a dynamic model of the vehicle-rack-bridge system based on train-track-bridge interaction theory,integrating gear-rack meshing and wheel-rail contact mechanisms.The model analyzes the dynamic response of bridges with varying spans under combined thermal and dynamic loading.Numerical simulations,conducted using finite element analysis,reveal peak vibration accelerations of 1.3 m/s^(2)for the rack,3.0 m/s^(2)for the rail,1.2 m/s^(2)for the sleeper,and 0.1 m/s^(2)for the bridge,with maximum stresses of 3 MPa in the rack,8 MPa in the rail,and 25 MPa in connecting bolts.The results show significant span-dependent amplification of stress and strain in the rack system under thermo-mechanical loading,exceeding material strength limits at 60-meter spans.An innovative elastic connection method is proposed to mitigate stress concentrations effectively,en-hancing system durability.This study introduces a novel approach to modeling complex thermo-mechanical interactions in rack railway systems,validated through extensive simulations,and provides a practical solution for improving structural resilience,offering theoretical guidance for optimizing rack-bridge system design to ensure operational safety in extreme environmental conditions.
基金the supports of the National Natural Science Foundation of China(Grant No.52375378)。
文摘The multi-pass intermittent local loading process,which features a more flexible processing path,can further enhance the second material distribution during local loading,improve the formability of components,and reduce forming loads.However,the absence of compatible forming equipment makes it difficult to control the constraint in the unloaded zones during the forming process.This difficulty complicates coordination and control of deformation,particularly for asymmetric rib-web components.Additionally,the current implementation involves multi-fire heating,a long process flow,and high energy consumption,which limits the popularization and application of the local loading process.In this study,a new multi-pass local loading hydraulic forming apparatus that can quickly and reliably switch between heavy-load deformation and low-load constraint for different local loading sub-dies was developed.A 10-tonne laboratory prototype was developed,and the forming characteristics during the forming process as well as the response characteristics of the hydraulic system during the multi-pass intermittent local loading of rib-web component were investigated using numerical simulations and physical experiments.Results indicated that,compared to a whole loading process with the same initial geometry of billet,the total forming load(i.e.,the sum of loaded and restrained loads)is reduced by more than 40%with the local loading process,and by nearly 50%with multi-pass local loading.The multi-pass local loading process allows for more effective control of material flow compared to single-pass local loading,leading to improved cavity filling and reduced flow line disturbance.For a large-scale,complex titanium alloy bulkhead,the cavity filling problem was addressed by optimizing the multi-pass local loading path with an unequal thickness billet.The dynamic performance of the multi-pass local loading hydraulic system was found to be robust,with stable pressure transitions during motion and load switching for the sub-die(s).The dynamic characteristic of the hydraulic cylinder when switching from non-moving/unloaded state to a moving/loading state are consistent whether a load is present or not.However,the dynamic characteristics differ when switching from a moving/loading state to non-moving/unloaded state,showing opposite behavior.The developed hydraulic drive mechanism provides a way for implementation of multi-pass local loading without auxiliary operation and extra heating.The results of the study provide a foundation for the industrial production of large-scale,complex components with reduced force requirement and low-energy consumption.
基金supported by the Nuclear Safety Research Program through the Korea Foundation of Nuclear Safety(KoFONS)using the financial resource granted by the Nuclear Safety and Security Commission(NSSC)of the Republic of Korea[RS-2025-02310881]the Korea Institute of Energy Technology Evaluation and Planning[KETEP]grant funded by the Ministry of Trade,Industry and Energy(MOTIE)[RS-2025-25447272].
文摘Unbonded post-tensioned(PT)concrete systems are widely used in safety-critical structures,yet model-ing practices for prestress implementation and tendon-concrete interaction remain inconsistent.This study investigates the effects of sheath(duct)implementation and confinement assumptions through nonlinear finite element analysis.Four modeling cases were defined,consisting of an explicit sheath without tendon-concrete confinement(S)and three no-sheath variants with different confinement levels(X,N,A).One-way beams and two-way panels were analyzed,and panel blast responses were validated against experimental results.In both beams and panels,average initial stress levels were similar across models,through local stress concentrations appeared when the sheath was modeled.Under blast loading,these local effects became critical,and the sheath-implemented model reproduced experimental behavior most accurately,whereas non-implemented models deviated.Reduced blast intensity diminished the differences among models,thereby reaffirming that sheath-induced localization and damage propagation are critical factors.These findings highlight the importance of explicit sheath implementation for realistic numerical assessment of unbonded PT structures under extreme loads.
基金supported by the National Natural Science Foundation with grant No.12374408。
文摘Air conditioning is a major energy-consuming component in buildings,and accurate air conditioning load forecasting is of great significance for maximizing energy utilization efficiency.However,the deep learning models currently used in the field of air conditioning load forecasting often suffer from issues such as distribution bias in load data and insufficient expression ability of nonlinear features in the model,which affect the accuracy of load forecasting.To address this,this paper proposes a novel load forecasting model.Firstly,the model employs the Dish-TS(DS)module to standardize the input window data through self-learning standardized parameters,thereby addressing the spatial intra-bias problem existing between data.Secondly,DS-Kansformer introduces Kolmogorov-Arnold Networks(KANs)to enhance the expression ability of nonlinear features.Finally,the output window is denormalized through the self-learning parameter of the DS module to restore the original distribution of the predicted data.In this paper,experiments were carried out based on the air-conditioning load dataset collected from a multi-functional comprehensive building,and the experimental results show that after adding the DS module,the Mean Absolute Error(MAE),Root Mean Square Error(RMSE),and R-squared(R^(2))of the model are 20.46%,34.44%,and 92.61%,respectively;after introducing KAN,the MAE,RMSE,and R^(2) are 22.81%,35.72%,and 92.05%,respectively;the model also exhibits high prediction accuracy after integrating the two modules(with RMSE,MAE,and R^(2) being 19.75%,34.05%,and 92.78%,respectively),outperforming common time series prediction models,confirming the reliability and efficiency of the model,which can provide reliable support for intelligent energy management in buildings.
基金supported by the Natural Science Foundation of China No.62303126the project Major Scientific and Technological Special Project of Guizhou Province([2024]014).
文摘This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater penetration,power grids are becoming increasingly vulnerable to cyber threats,potentially leading to frequency instability and widespread disruptions.We model two significant attack vectors:load-altering attacks(LAAs)and false data injection attacks(FDIAs)that corrupt frequency measurements.These are analyzed for their impact on grid frequency stability in both linear and nonlinear LFC models,incorporating generation rate constraints and nonlinear loads.A coordinated attack strategy is presented,combining LAAs and FDIAs to achieve stealthiness by concealing frequency deviations from system operators,thereby maximizing disruption while evading traditional detection.To counteract these threats,we propose an Unknown Input Observer(UIO)-based detection framework for linear and nonlinear LFCs.The UIO is designed using linear matrix inequalities(LMIs)to estimate system states while isolating unknown attack inputs,enabling attack detection through monitoring measurement residuals against a predefined threshold.For mitigation,we leverage BESS capabilities with two adaptive strategies:dynamic mitigation for dynamic LAAs,which tunes BESS parameters to enhance the system’s stability margin and accelerate convergence to equilibrium;and staticmitigation for static LAAs and FDIAs.Simulations show that the UIO achieves high detection accuracy,with residuals exceeding thresholds promptly under coordinated attacks,even in nonlinear models.Mitigation strategies reduce frequency deviations by up to 80%compared to unmitigated cases,restoring stability within seconds.
基金supported by the Major Research Development Program of Hubei Province,China(Grant Nos.2022BAA093 and 2022BAD163)the Open Research Fund of the State Key Laboratory of Geomechanics and Geotechnical Engineering,Institute of Rock and Soil Mechanics,Chinese Academy of Sciences(Grant No.SKLGME023008).
文摘With the growing global demand for energy,deep underground salt caverns are emerging as a potential solution for large-scale energy storage.In this study,multistage cyclic loading tests were conducted on rock salt at different temperatures in combination with real-time acoustic emission(AE)monitoring.The results show that the cumulative AE count increases stepwise with increasing cyclic stress.The peak frequency is concentrated primarily in the medium-frequency range,exhibiting a band distribution across low-,medium-,and high-frequency ranges.As the temperature increases,the proportion of low-frequency signals decreases from 14.32%to 5.76%,whereas the proportion of medium-frequency signals increases from 85.48%to 94.1%.The proportion of high-frequency signals remains relatively constant between 0.1%and 0.2%.The amplitude-count relationship of the AE signals demonstrates a strong negative power-law correlation.Furthermore,with increasing temperature,the negative power-law exponent of the amplitude gradually decreases,with the b value decreasing from 1.096 to 0.837 and the a value decreasing from 7.4871 to 6.6982.Under all four temperature conditions,the dominant failure mode in rock salt is tensile cracking.However,as the temperature increases,the proportion of tensile cracks decreases from 88.59%to 75.12%,whereas the proportion of shear cracks at 80℃is nearly double that at 20℃.This finding indicates that as the temperature increases,the ductility of the material increases,and the crack propagation mode shifts from tensile to shear.This research provides valuable insights for the design and stability assessment of salt cavern reservoirs for deep underground energy storage systems.
基金Supported by National Natural Science Foundation of China(Grant No.U2141246)Key Laboratory of Artillery Launch and Control Technology of China(Grant No.2021-001)Basic Research of State Administration of Science Technology and Industry for National Defense of China(Grant No.JXJL202208A001).
文摘The automatic loading systems of artillery are critical for the accurate,efficient,and reliable delivery of pro-jectiles and propellants into the gun chamber.In modern artillery,the ammunition conveyor serves as the end effector of the automatic loading system,and its motion state significantly impacts the accuracy of projectiles.Therefore,it is of immense importance to precisely and effectively evaluate the reliability of the motion accuracy of the ammunition conveyor.This paper aims to propose a practical and efficient analysis method for evaluating the reliability of the motion accuracy of the ammunition conveyor.The proposed approach involves the use of a deep learning network to approximate the physical model and the extremum method to obtain a single cycle sequence decoupling strategy for solving the time-varying reliability issue of complex systems.Employing this strategy,the time-varying reliability of the ammunition conveyor is transformed into a static reliability problem.The proposed method includes the use of a deep feedforward neural network,second-order saddle point ap-proximation(SPA)method,extremum method,and efficient global optimization(EGO)technology.The results reveal that the reliability of the motion accuracy of the ammunition conveyor is 93.42%,with the maximum failure probability occurring at 0.21 s.These results serve as an important reference for the structural optimi-zation design of the ammunition conveyor based on reliability and the maintenance of the operational process.
基金sponsored by National Natural Science Foundation of China(Grant Nos.U22B6003 and 52304070)Key Laboratory of Geomechanics and Geotechnical Engineering Safety,Chinese Academy of Sciences(Grant No.SKLGME-JBGS2404).
文摘Large-scale geological energy storage plays a crucial role in balancing the intermittency of renewable energy.As an energy storage medium,soaked sandstone has a wide range of applications in geological energy storage.Understanding the damage characteristics in soaked sandstones is essential for ensuring the stability and longevity of these energy storage systems.This study involved multi-stage cyclic loading tests conducted on soaked sandstone to explore the damage evolution throughout the loading process.The findingsreveal several important insights:(1)The plastic hysteresis loops observed during multi-stage cyclic loading evolved from dense to sparse.An increase in stress level led to greater damage in the rock,as evidenced by an increase in accumulated peak/plastic strains.(2)Energy density and stress level are related by quadratic polynomial relationships.The elastic and dissipated energy densities are related by a linear law.The average energy storage coefficientdecreased by up to 24.1%with increasing stress amplitude,reflectingchanges in energy dynamics within the samples.(3)AE counts,amplitude,and frequency provided critical insights into rock damage and fracture patterns.The greater the loading rate and stress amplitude,the lower the proportion of high-amplitude,high-peak frequency,and shear-type fractures.Increasing stress amplitude caused a maximum 16.63%reduction in the AE bvalue,indicating shifts in fracture behavior under varying stress conditions.(4)The increase in loading rate and stress amplitude promotes the transformation of micropores and mesopores to macropores/microcracks.(5)Damage variables,definedin terms of cumulative dissipation energy,aligned closely with the fatigue damage model under multi-stage cyclic loading.Accelerated damage primarily occurred during the finalstages of fatigue loading,highlighting critical periods in the degradation of soaked sandstones.This study can offer guidance for designing operational parameters for energy storage geological bodies dominated by soaked sandstones.
文摘This study investigates the performance of high-strength cable bolts under impact loading conditions representative of rock bursts in underground environments.Although widely used,the dynamic behaviour of these cable bolts has received limited experimental attention,and their effectiveness in seismically active zones remains a subject of ongoing debate.To address this gap,a reverse pull-out test machine integrated with a drop hammer rig was employed.Tests were conducted on 70-t SUMO bulbed and non-bulbed cable bolts with encapsulation lengths of 300 and 450 mm,subjected to an impact energy of 14.52 k J.Results indicate that non-bulbed cables,despite showing lower initial peak loads(average 218 vs.328 k N for bulbed cables at 300 mm encapsulation),demonstrated superior energy absorption(average 11.26 vs.8.75 k J)and displacement capacity(average 48.40 vs.36.25 mm).Increasing the encapsulation length for bulbed cables led to a reduction in initial peak load but improved displacement and energy absorption.The dominant failure mechanism was debonding at the cable-grout interface,characterised by frictional sliding and cable rotation.These findings provide new insights into the energy dissipation mechanisms of cables and support the development of more resilient ground support systems for dynamically active conditions.
基金supported by the National Natural Science Foundation of China(52471132,52475356,12272192,52475344,U21A20130)the Natural Science Foundation of Fujian Province for Distinguished Young Scholars(2024J010031)as well as the Natural Science Foundation of Chongqing(grant number CSTB2023NSCQ-MSX0886).
文摘Investigating effect of recrystallization mechanism on deformation mode and texture evolution is conducive to controlling deformation mechanism and texture in magnesium alloys under medium-high temperature impact loading.In the present study,a Johnson-Cook model incorporating twin strengthening was established to simulate macro-deformation,and a twinning induced recrystallization(TDRX)model and bulging recrystallization(GBBDRX)model are introduced into visco-plastic self consistant(VPSC)framework to quantitatively study the deformation mechanism of pre-twinned AZ31 magnesium alloy during medium-high temperature impact loading.Both TDRX and GBBDRX occur,with basal slip as the dominant slip system,followed by pyramidal〈c+a〉slip and prismatic slip.The dynamic recrystallization(DRX)significantly influences basal and pyramidal〈c+a〉slip systems,with minimal impact on secondary deformation mechanism.In addition,the recrystallization mechanism of grain boundary bowing increases the activity of basal slip and decreases the activity of pyramidal〈c+a〉slip.The nucleation and growth of recrystallized grains enhance basal slip activity and suppress pyramidal〈c+a〉slip,leading to the formation of a strong basal texture.As dynamic recrystallization progresses,a bimodal texture develops,characterized by a reduction in basal component pole density and a more pronounced basal slip.
基金supported by the National Natural Science Foundation of China(Grant No.32160172)the Key Science-Technology Project of Inner Mongolia(2023KYPT0010)+1 种基金the Natural Science Foundation of Inner Mongolia Autonomous Region of China(Grant No.2025QN03006)the 2023 Inner Mongolia Public Institution High-level Talent Introduction Scientific Research Support Project.
文摘This study establishes and validates a method for the precise quantification of aquatic microbial loads using microbial diversity absolute quantitative sequencing.By adding synthetic spike-in DNA to water samples from the Dahei River prior to DNA extraction and 16S rRNA gene sequencing,it generates standard curves to convert sequencing data into absolute microbial copy numbers.The method,which is proved highly accurate(R^(2)>0.99),reveals a clear contrast between the river sites:the upstream community has not only a significantly higher total microbial load but also a completely different makeup of species compared to the downstream site.This approach effectively overcomes the limitations of relative abundance analysis,providing a powerful tool for environmental monitoring,and proposes key steps for future standardization to ensure data comparability and integration.