With the increasing complexity of distribution network structures originating from the high penetration of renewable energy and responsive loads,fast and accurate fault location technology for distribution networks is...With the increasing complexity of distribution network structures originating from the high penetration of renewable energy and responsive loads,fast and accurate fault location technology for distribution networks is a prerequisite for rapid isolation of faults and restoration of the power supply.In this paper,a fault location method based on community graph depth-first traversal is proposed for fast location of single-phase ground faults in distribution networks.First,this paper defines the fault graph weight of the vertices in the distribution network graph model,which can be used to reflect the topology of the vertices and fault points as well as the fluctuation of the vertices’currents.Then,the vertices on the graph model are clustered by using an improved parallel louvain method(IPLM).Finally,the community formed by IPLM is used as the smallest unit for depth-first traversal to achieve fast and accurate location of the fault section.The paper develops a distribution network graph model of IEEE 33-bus system on the graph database for testing.And three other methods are selected for comparison with IPLMDF.The test results show that IPLMDF can achieve fast and accurate fault location when half of the nodes in the distribution network are equipped with D-PMUs.When some of the D-PMUs lose time synchronization,it is still possible to locate the fault section,and at the same time,the locating results can be avoided by falling into local optimal solutions.展开更多
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei...Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs.展开更多
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing...It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.展开更多
Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults...Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults.Because of the weak fault current and imperfect monitoring equipment configurations,methods used to determine the faulty line secti ons with SPG faults in NIGSs are in effective.The developme nt and application of distributi on-level phasor measurement units(PMUs)provide further comprehensive fault information for fault diagnosis in a distribution network.When an SPG fault occurs,the transient energy of the faulted line section tends to be higher than the sum of the transient energies of other line sections.In this regard,transient energy-based fault location algorithms appear to be a promising resolution.In this study,a field test plan was designed and implemented for a 10 kV distribution network.The test results dem on strate the effective ness of the transient en ergy-based SPG locati on method in practical distributi on networks.展开更多
Due to the wide and adjustable emission range,Ce^(3+)is an indispensable luminous center for full spectrum lighting.However,it needs to be sintered at high temperature in a reducing atmosphere,resulting in difficulty ...Due to the wide and adjustable emission range,Ce^(3+)is an indispensable luminous center for full spectrum lighting.However,it needs to be sintered at high temperature in a reducing atmosphere,resulting in difficulty to coexisting with other multivalent activated ions(such as Eu^(3+),Tm^(3+)),which greatly hinders the formation of full spectrum.In this study,a calcium vacancy enhanced self-reduction of Ce^(4+)is realized in CaNaSb_(2)O_(6)F(CNSOF)host under air atmosphere sintering,through which Ce^(3+),Tm^(3+)and Eu^(3+)coexisting in a single-phase full spectrum phosphor was prepared.Notably,the artificial introduction of a calcium vacancy was designed to verify this self-reduction mechanism.Moreover,the energy transfer kinetics among Tm^(3+),Ce^(3+)and Eu^(3+)were explored.Finally,combined with a 340 nm UV chip,a full spectrum phosphor-converted light-emitting diode(pc-LED)was fabricated,showing a broad emission range from 400 to 750 nm,Commission Internationale de I'Edairage(CIE)of(0.3485,0.3673),Ra of 92 and correlated color temperature(CCT)of 4933 K.Utilizing the variation in emission colors of this phosphor under different UV wavelengths,a dual encryption method combining point character code and fluorescent encryption technique is proposed.This work provides an effective path for Ce^(4+)self-reduction to apply in full spectrum pc-LED and information encryption.展开更多
In order to increase the stability of the Mongolia power system, a single-phase automatic reclosing device (SPAR) was introduced on double-circuit power lines built with a size of 330 kV, operating on a voltage of 220...In order to increase the stability of the Mongolia power system, a single-phase automatic reclosing device (SPAR) was introduced on double-circuit power lines built with a size of 330 kV, operating on a voltage of 220 kV and a length of 250 km. These overhead power lines (L-213, L-214) connect the 220/110/35 kV “Songino” substation with the “Mandal” substation and form system networks. This paper presents the challenges encountered when implementing single-phase automatic reclosing (SPAR) devices and compares the changes in power system parameters before and after SPAR deployment for a long 220 kV line. Simulations and analyses were carried out using DIgSILENT PowerFactory software, focusing on rotor angle stability, and the overall impact on the power system during short-circuit faults. The evaluation also utilized measurement data from the Wide Area Monitoring System (WAMS) to compare system behavior pre- and post-implementation of SPAR. The findings reveal that SPAR significantly enhances system reliability and stability, effectively mitigating the risk of oscillations and stability loss triggered by short circuits. This improvement contributes to a more resilient power system, reducing the potential for disturbances caused by faults.展开更多
In order to avoid the UHVAC (Ultra High Voltage Alternating Current) transmission line with shunt reactor fault voltage smaller problems, through the analysis of single-phase permanent fault when tripping phase termin...In order to avoid the UHVAC (Ultra High Voltage Alternating Current) transmission line with shunt reactor fault voltage smaller problems, through the analysis of single-phase permanent fault when tripping phase terminal voltage characteristics, this paper presents a fault phase voltage signal of the two order derivative and the original signal ratio of a new method for steady-state frequency discrimination single-phase permanent fault. The principle of this method is simple, and it can avoid the problem that the fault voltage caused by the installation of shunt reactor is small. The adaptability and correctness of the proposed method are verified by a large number of simulations.展开更多
Grid-Forming(GFM)converters are prone to fault-induced overcurrent and power angle instability during grid fault-induced voltage sags.To address this,this paper develops a multi-loop coordinated fault ridethrough(FRT)...Grid-Forming(GFM)converters are prone to fault-induced overcurrent and power angle instability during grid fault-induced voltage sags.To address this,this paper develops a multi-loop coordinated fault ridethrough(FRT)control strategy based on a power outer loop and voltage-current inner loops,aiming to enhance the stability and current-limiting capability of GFM converters during grid fault conditions.During voltage sags,the GFM converter’s voltage source behavior is maintained by dynamically adjusting the reactive power reference to provide voltage support,thereby effectively suppressing the steady-state component of the fault current.To address the active power imbalance induced by voltage sags,a dynamic active power reference correction method based on apparent power is designed to mitigate power angle oscillations and limit transient current.Moreover,an adaptive virtual impedance loop is implemented to enhance dynamic transient current-limiting performance during the fault initiation phase.This approach improves the responsiveness of the inner loop and ensures safe system operation under various fault severities.Under asymmetric fault conditions,a negative-sequence reactive current compensation strategy is incorporated to further suppress negative-sequence voltage and improve voltage symmetry.The proposed control scheme enables coordinated operation of multiple control objectives,including voltage support,current suppression,and power angle stability,across different fault scenarios.Finally,MATLAB/Simulink simulation results validate the effectiveness of the proposed strategy,showcasing its superior performance in current limiting and power angle stability,thereby significantly enhancing the system’s fault ride-through capability.展开更多
This paper investigates the reliability of internal marine combustion engines using an integrated approach that combines Fault Tree Analysis(FTA)and Bayesian Networks(BN).FTA provides a structured,top-down method for ...This paper investigates the reliability of internal marine combustion engines using an integrated approach that combines Fault Tree Analysis(FTA)and Bayesian Networks(BN).FTA provides a structured,top-down method for identifying critical failure modes and their root causes,while BN introduces flexibility in probabilistic reasoning,enabling dynamic updates based on new evidence.This dual methodology overcomes the limitations of static FTA models,offering a comprehensive framework for system reliability analysis.Critical failures,including External Leakage(ELU),Failure to Start(FTS),and Overheating(OHE),were identified as key risks.By incorporating redundancy into high-risk components such as pumps and batteries,the likelihood of these failures was significantly reduced.For instance,redundant pumps reduced the probability of ELU by 31.88%,while additional batteries decreased the occurrence of FTS by 36.45%.The results underscore the practical benefits of combining FTA and BN for enhancing system reliability,particularly in maritime applications where operational safety and efficiency are critical.This research provides valuable insights for maintenance planning and highlights the importance of redundancy in critical systems,especially as the industry transitions toward more autonomous vessels.展开更多
A novel white-light emitting single-phase phosphor La_3 Si_6 N_(11):Dy^(3+),exhibiting two emission peaks centering at 475 and 575 nm, was prepared via conventional solid-state reactions. The structure and morphology ...A novel white-light emitting single-phase phosphor La_3 Si_6 N_(11):Dy^(3+),exhibiting two emission peaks centering at 475 and 575 nm, was prepared via conventional solid-state reactions. The structure and morphology of La_3 Si_6 N_(11):Dy^(3+)/Tb^(3+) were investigated by X-ray diffraction(XRD) and scanning electron microscopy(SEM). The emission colors can be tuned from white to yellow-green through increasing the Tb^(3+) concentration in La_3 Si_6 N_(11):Dy^(3+),Tb^(3+), The mechanism of energy transfer(ET) from Dy^(3+) to Tb^(3+) is confirmed according to the excitation,emission spectra and decay lifetimes curve. The temperaturedependent luminescence measurements of La_(2.83)Si_6 N_(11):0.1 Dy^(3+),0.07 Tb^(3+) were also performed, and a good thermal stability is shown, suggesting superior properties for the application as white lightemitting diodes(w-LEDs) phosphor.展开更多
The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results sho...The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results show that the Mg-1.5Zn-0.6Zr alloy had a single-phase solid solution structure,with an average grain size of 34.7±13.1μm.The alloy exhibited ultimate tensile strength of 168±2.0 MPa,yield strength of 83±0.6 MPa,and elongation of 9.1±0.6%.Immersion tests and electrochemical measurements reveal that the alloy displayed lower biocorrosion rate and more uniform corrosion mode than AZ91D in Hank's solution.The elimination of intensive galvanic corrosion reactions and the formation of a much more compact and uniform corrosion film mainly account for the better biocorrosion properties of the Mg-1.5Zn-0.6Zr alloy than AZ91D.展开更多
This study focuses on the effects of rotational and welding speeds on the microstructure and hardness of joints in friction stir welded single-phase brass. Welds were achieved under low heat input conditions at rotati...This study focuses on the effects of rotational and welding speeds on the microstructure and hardness of joints in friction stir welded single-phase brass. Welds were achieved under low heat input conditions at rotational and welding speeds of 400-800 r/min and 100-300 mm/min, respectively. In order to characterize the obtained welds, optical microscopy and Vickers hardness measurements were taken on the weld cross sections. According to the obtained results, increasing the welding speed and/or decreasing the rotational speed caused the grain size of the stir zone to decrease and, hence, improved the average hardness of this region. These results are discussed with respect to the interplay between the welding parameters and the peak temperature in the weld thermal cycle.展开更多
A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reacti...A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reaction time, initial molybdenum concentration, initial NH_3 /Mo molar ratio, and stirring speed. Under the optimum experimental conditions, the crystallization rate of product is 85.23%. The X-ray diffraction (XRD) analysis and chemical analysis show that the product is single-phase ammonium dimolybdate, and no impurity phases exist. The scanning electronic microscope (SEM) image reveals uniform particle size, good particle dispersion, and no agglomeration between particles. Meanwhile, the final pH value of acidification was investigated. The total molybdenum recovery can reach up to 99.40%, and the main phases of acidification product are the same as those of raw material with the final pH value of 1.5. This determines that the acidification product can be used as a raw material to produce single-phase ammonium dimolybdate.展开更多
Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were estab...Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.展开更多
Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops ...Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops of CBM column from well head to bottom hole.The measured parameters and independent variables of flow rates,flowing pressures and temperatures are involved in CBM producing process along the annulus.The developed relationships are validated against full-scale measured data in single-phase CBM wellbores.The proposed methodology can analyze the dynamic behavior in CBM reservoir and process of CBM flow with an overall accuracy of 2%.The calculating process of flowing pressures involves friction factor with variable Reynolds number and CBM temperature and compressibility factor with gravitational gradients.The results showed that the effect of flowing pressure on CBM column was more obvious than that on CBM and water column accompanied by an increase of dynamic water level.The ratios of flowing pressure on increment of CBM column to the whole column increased with the declined flow rates of water column.Bottom-hole pressure declined with the decreased flowing pressure of CBM column along the annulus.It will lead to the results of the increased pressure drop of CBM column and CBM flow rate in single-phase CBM wellbores.展开更多
Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling ...Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling is responsible for 40%of the usage.Therefore,this research proposes the immersion cooling method to solving the high energy consumption of data centers by cooling its component using two types of dielectric fluids.Four stages of experimentalmethods are used,such as fluid types,cooling effectiveness,optimization,and durability.Furthermore,benchmark software is used to measure the CPU maximum work with the temperature data performed for 24 h.The results of this study show that the immersion cooling reduces 13℃ lower temperature than the conventional cooling method which means it saves more energy consumption in the data center.The most optimum variable used to decrease the temperature is 1.5 lpm of flow rate and 800 rpm of fan rotation.Furthermore,the cooling performance of the dielectric fluids shows that the mineral oil(MO)is better than the virgin coconut oil(VCO).In durability experiment,there are no components damage after five months immersed in the fluid.展开更多
Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and contr...Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.展开更多
The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational pri...The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.展开更多
基金supported by the National Natural Science Foundation of China (Grant Nos.52009106,51779206)the National Key R&D Program of China (No.2018YFB1500800)the Natural Science Fund Youth Project of Shaanxi Province (2019J-130).
文摘With the increasing complexity of distribution network structures originating from the high penetration of renewable energy and responsive loads,fast and accurate fault location technology for distribution networks is a prerequisite for rapid isolation of faults and restoration of the power supply.In this paper,a fault location method based on community graph depth-first traversal is proposed for fast location of single-phase ground faults in distribution networks.First,this paper defines the fault graph weight of the vertices in the distribution network graph model,which can be used to reflect the topology of the vertices and fault points as well as the fluctuation of the vertices’currents.Then,the vertices on the graph model are clustered by using an improved parallel louvain method(IPLM).Finally,the community formed by IPLM is used as the smallest unit for depth-first traversal to achieve fast and accurate location of the fault section.The paper develops a distribution network graph model of IEEE 33-bus system on the graph database for testing.And three other methods are selected for comparison with IPLMDF.The test results show that IPLMDF can achieve fast and accurate fault location when half of the nodes in the distribution network are equipped with D-PMUs.When some of the D-PMUs lose time synchronization,it is still possible to locate the fault section,and at the same time,the locating results can be avoided by falling into local optimal solutions.
基金supported in part by National Key Research and Development Program of China(2016YFB0900603)Technology Projects of State Grid Corporation of China(52094017000W).
文摘Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs.
文摘It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.
基金National Key R&D Program of China(2017YFB0902800)Science and Technology Project of State Grid Corporation of China(52094017003D)supported this work.
文摘Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults.Because of the weak fault current and imperfect monitoring equipment configurations,methods used to determine the faulty line secti ons with SPG faults in NIGSs are in effective.The developme nt and application of distributi on-level phasor measurement units(PMUs)provide further comprehensive fault information for fault diagnosis in a distribution network.When an SPG fault occurs,the transient energy of the faulted line section tends to be higher than the sum of the transient energies of other line sections.In this regard,transient energy-based fault location algorithms appear to be a promising resolution.In this study,a field test plan was designed and implemented for a 10 kV distribution network.The test results dem on strate the effective ness of the transient en ergy-based SPG locati on method in practical distributi on networks.
基金Project supported by National Natural Science Foundation of China(62075203,12304460)Zhejiang Provincial Natural Science Foundation of China(LQ23A040007)Basic Public Welfare Research Program of Zhejiang Province(LDT23F05013F05)。
文摘Due to the wide and adjustable emission range,Ce^(3+)is an indispensable luminous center for full spectrum lighting.However,it needs to be sintered at high temperature in a reducing atmosphere,resulting in difficulty to coexisting with other multivalent activated ions(such as Eu^(3+),Tm^(3+)),which greatly hinders the formation of full spectrum.In this study,a calcium vacancy enhanced self-reduction of Ce^(4+)is realized in CaNaSb_(2)O_(6)F(CNSOF)host under air atmosphere sintering,through which Ce^(3+),Tm^(3+)and Eu^(3+)coexisting in a single-phase full spectrum phosphor was prepared.Notably,the artificial introduction of a calcium vacancy was designed to verify this self-reduction mechanism.Moreover,the energy transfer kinetics among Tm^(3+),Ce^(3+)and Eu^(3+)were explored.Finally,combined with a 340 nm UV chip,a full spectrum phosphor-converted light-emitting diode(pc-LED)was fabricated,showing a broad emission range from 400 to 750 nm,Commission Internationale de I'Edairage(CIE)of(0.3485,0.3673),Ra of 92 and correlated color temperature(CCT)of 4933 K.Utilizing the variation in emission colors of this phosphor under different UV wavelengths,a dual encryption method combining point character code and fluorescent encryption technique is proposed.This work provides an effective path for Ce^(4+)self-reduction to apply in full spectrum pc-LED and information encryption.
文摘In order to increase the stability of the Mongolia power system, a single-phase automatic reclosing device (SPAR) was introduced on double-circuit power lines built with a size of 330 kV, operating on a voltage of 220 kV and a length of 250 km. These overhead power lines (L-213, L-214) connect the 220/110/35 kV “Songino” substation with the “Mandal” substation and form system networks. This paper presents the challenges encountered when implementing single-phase automatic reclosing (SPAR) devices and compares the changes in power system parameters before and after SPAR deployment for a long 220 kV line. Simulations and analyses were carried out using DIgSILENT PowerFactory software, focusing on rotor angle stability, and the overall impact on the power system during short-circuit faults. The evaluation also utilized measurement data from the Wide Area Monitoring System (WAMS) to compare system behavior pre- and post-implementation of SPAR. The findings reveal that SPAR significantly enhances system reliability and stability, effectively mitigating the risk of oscillations and stability loss triggered by short circuits. This improvement contributes to a more resilient power system, reducing the potential for disturbances caused by faults.
文摘In order to avoid the UHVAC (Ultra High Voltage Alternating Current) transmission line with shunt reactor fault voltage smaller problems, through the analysis of single-phase permanent fault when tripping phase terminal voltage characteristics, this paper presents a fault phase voltage signal of the two order derivative and the original signal ratio of a new method for steady-state frequency discrimination single-phase permanent fault. The principle of this method is simple, and it can avoid the problem that the fault voltage caused by the installation of shunt reactor is small. The adaptability and correctness of the proposed method are verified by a large number of simulations.
文摘Grid-Forming(GFM)converters are prone to fault-induced overcurrent and power angle instability during grid fault-induced voltage sags.To address this,this paper develops a multi-loop coordinated fault ridethrough(FRT)control strategy based on a power outer loop and voltage-current inner loops,aiming to enhance the stability and current-limiting capability of GFM converters during grid fault conditions.During voltage sags,the GFM converter’s voltage source behavior is maintained by dynamically adjusting the reactive power reference to provide voltage support,thereby effectively suppressing the steady-state component of the fault current.To address the active power imbalance induced by voltage sags,a dynamic active power reference correction method based on apparent power is designed to mitigate power angle oscillations and limit transient current.Moreover,an adaptive virtual impedance loop is implemented to enhance dynamic transient current-limiting performance during the fault initiation phase.This approach improves the responsiveness of the inner loop and ensures safe system operation under various fault severities.Under asymmetric fault conditions,a negative-sequence reactive current compensation strategy is incorporated to further suppress negative-sequence voltage and improve voltage symmetry.The proposed control scheme enables coordinated operation of multiple control objectives,including voltage support,current suppression,and power angle stability,across different fault scenarios.Finally,MATLAB/Simulink simulation results validate the effectiveness of the proposed strategy,showcasing its superior performance in current limiting and power angle stability,thereby significantly enhancing the system’s fault ride-through capability.
基金supported by Istanbul Technical University(Project No.45698)supported through the“Young Researchers’Career Development Project-training of doctoral students”of the Croatian Science Foundation.
文摘This paper investigates the reliability of internal marine combustion engines using an integrated approach that combines Fault Tree Analysis(FTA)and Bayesian Networks(BN).FTA provides a structured,top-down method for identifying critical failure modes and their root causes,while BN introduces flexibility in probabilistic reasoning,enabling dynamic updates based on new evidence.This dual methodology overcomes the limitations of static FTA models,offering a comprehensive framework for system reliability analysis.Critical failures,including External Leakage(ELU),Failure to Start(FTS),and Overheating(OHE),were identified as key risks.By incorporating redundancy into high-risk components such as pumps and batteries,the likelihood of these failures was significantly reduced.For instance,redundant pumps reduced the probability of ELU by 31.88%,while additional batteries decreased the occurrence of FTS by 36.45%.The results underscore the practical benefits of combining FTA and BN for enhancing system reliability,particularly in maritime applications where operational safety and efficiency are critical.This research provides valuable insights for maintenance planning and highlights the importance of redundancy in critical systems,especially as the industry transitions toward more autonomous vessels.
基金supported by the National Key Research and Development Plan(2017YFB0404300,2017YFB0404301)
文摘A novel white-light emitting single-phase phosphor La_3 Si_6 N_(11):Dy^(3+),exhibiting two emission peaks centering at 475 and 575 nm, was prepared via conventional solid-state reactions. The structure and morphology of La_3 Si_6 N_(11):Dy^(3+)/Tb^(3+) were investigated by X-ray diffraction(XRD) and scanning electron microscopy(SEM). The emission colors can be tuned from white to yellow-green through increasing the Tb^(3+) concentration in La_3 Si_6 N_(11):Dy^(3+),Tb^(3+), The mechanism of energy transfer(ET) from Dy^(3+) to Tb^(3+) is confirmed according to the excitation,emission spectra and decay lifetimes curve. The temperaturedependent luminescence measurements of La_(2.83)Si_6 N_(11):0.1 Dy^(3+),0.07 Tb^(3+) were also performed, and a good thermal stability is shown, suggesting superior properties for the application as white lightemitting diodes(w-LEDs) phosphor.
基金This project was supported by the National Natural Science Foundation of China(No.51174025)Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20110006130004).
文摘The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results show that the Mg-1.5Zn-0.6Zr alloy had a single-phase solid solution structure,with an average grain size of 34.7±13.1μm.The alloy exhibited ultimate tensile strength of 168±2.0 MPa,yield strength of 83±0.6 MPa,and elongation of 9.1±0.6%.Immersion tests and electrochemical measurements reveal that the alloy displayed lower biocorrosion rate and more uniform corrosion mode than AZ91D in Hank's solution.The elimination of intensive galvanic corrosion reactions and the formation of a much more compact and uniform corrosion film mainly account for the better biocorrosion properties of the Mg-1.5Zn-0.6Zr alloy than AZ91D.
文摘This study focuses on the effects of rotational and welding speeds on the microstructure and hardness of joints in friction stir welded single-phase brass. Welds were achieved under low heat input conditions at rotational and welding speeds of 400-800 r/min and 100-300 mm/min, respectively. In order to characterize the obtained welds, optical microscopy and Vickers hardness measurements were taken on the weld cross sections. According to the obtained results, increasing the welding speed and/or decreasing the rotational speed caused the grain size of the stir zone to decrease and, hence, improved the average hardness of this region. These results are discussed with respect to the interplay between the welding parameters and the peak temperature in the weld thermal cycle.
基金supported by the National Natural Science Foundation of China(No.51072233)
文摘A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reaction time, initial molybdenum concentration, initial NH_3 /Mo molar ratio, and stirring speed. Under the optimum experimental conditions, the crystallization rate of product is 85.23%. The X-ray diffraction (XRD) analysis and chemical analysis show that the product is single-phase ammonium dimolybdate, and no impurity phases exist. The scanning electronic microscope (SEM) image reveals uniform particle size, good particle dispersion, and no agglomeration between particles. Meanwhile, the final pH value of acidification was investigated. The total molybdenum recovery can reach up to 99.40%, and the main phases of acidification product are the same as those of raw material with the final pH value of 1.5. This determines that the acidification product can be used as a raw material to produce single-phase ammonium dimolybdate.
基金Project supported by the National Natural Science Foundation of China(Grant No.51107016)the National Basic Research Program of China(Grant No.2013CB035605)the Postdoctoral Science Research Developmental Foundation of Heilongjiang Province,China(Grant No.LHB-Q12086)
文摘Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.
基金This work was financially supported by National Science and Technology Major Project of the Ministry of Science and Technology of China(2016ZX05065-001),Key Research Project of Shandong Province(2019GHY112029 and 2019GSF109090)and Higher Education Research and Development Project of Shandong Province(J17KA033).
文摘Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops of CBM column from well head to bottom hole.The measured parameters and independent variables of flow rates,flowing pressures and temperatures are involved in CBM producing process along the annulus.The developed relationships are validated against full-scale measured data in single-phase CBM wellbores.The proposed methodology can analyze the dynamic behavior in CBM reservoir and process of CBM flow with an overall accuracy of 2%.The calculating process of flowing pressures involves friction factor with variable Reynolds number and CBM temperature and compressibility factor with gravitational gradients.The results showed that the effect of flowing pressure on CBM column was more obvious than that on CBM and water column accompanied by an increase of dynamic water level.The ratios of flowing pressure on increment of CBM column to the whole column increased with the declined flow rates of water column.Bottom-hole pressure declined with the decreased flowing pressure of CBM column along the annulus.It will lead to the results of the increased pressure drop of CBM column and CBM flow rate in single-phase CBM wellbores.
基金This work is financially supported by the Ministry of Research and Technology of Indonesia(BRIN)in the project called“Penggunaan Immersion Cooling untukMeningkatkan Efisiensi Energi Data Center”.
文摘Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling is responsible for 40%of the usage.Therefore,this research proposes the immersion cooling method to solving the high energy consumption of data centers by cooling its component using two types of dielectric fluids.Four stages of experimentalmethods are used,such as fluid types,cooling effectiveness,optimization,and durability.Furthermore,benchmark software is used to measure the CPU maximum work with the temperature data performed for 24 h.The results of this study show that the immersion cooling reduces 13℃ lower temperature than the conventional cooling method which means it saves more energy consumption in the data center.The most optimum variable used to decrease the temperature is 1.5 lpm of flow rate and 800 rpm of fan rotation.Furthermore,the cooling performance of the dielectric fluids shows that the mineral oil(MO)is better than the virgin coconut oil(VCO).In durability experiment,there are no components damage after five months immersed in the fluid.
基金This work is funded by the Anhui Natural Science Foundation Project of China(under Grant KJ2016A201)the National Natural Science Foundation of China(under Grant 11774378).
文摘Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.
基金Project (No. 50477033) supported by the National Natural ScienceFoundation of China
文摘The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.