期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Identification of Key Parameters for Temporary Guy Ropes in Sloping Central Tower Column and Brace Construction
1
作者 Renfei Chang Liqiang Jin +2 位作者 Haihui Xie Kai Zhang Musheng Ye 《Structural Durability & Health Monitoring》 2026年第1期161-177,共17页
To investigate the impact of temporary structures on the mechanical behavior of shaped bridge towers during the construction process,the Dianbu River Special Bridge was selected as the engineering background.A finite ... To investigate the impact of temporary structures on the mechanical behavior of shaped bridge towers during the construction process,the Dianbu River Special Bridge was selected as the engineering background.A finite element model of the middle tower column during the construction stage was established using ABAQUS to analyze the effects of key parameters,including the angle and pretension of temporary cables,as well as the wall thickness and diameter of temporary diagonal braces.The study examines how these parameters influence the stresses at the towergirder consolidation.The results indicate that the angle of temporary cables significantly affects the tensile stresses at the tower-girder consolidation,while its impact on compressive stresses is minimal.Among all parameters,the pretension of temporary cables has the most pronounced effect on the stresses at the tower-girder consolidation.In contrast,the wall thickness of temporary diagonal braces has only a minor influence,whereas the diameter of temporary diagonal braces has an almost negligible impact.These findings provide valuable insights for optimizing the design and arrangement of temporary support structures in similar bridge construction projects. 展开更多
关键词 Anisotropic single tower cable-stayed bridge influence degree identification temporary cables temporary diagonal braces construction control
在线阅读 下载PDF
Comprehensive Optimal Control on Seismic Response of a Single-Tower Self-Anchored Suspension Bridge 被引量:1
2
作者 WANG Hao LI Aiqun JIAO Changke 《Wuhan University Journal of Natural Sciences》 CAS 2011年第1期55-63,共9页
Earthquake may cause severe damage to all kinds of bridge such as the falling down of the girder; therefore,effective measures should be employed to control the seismic displacement. In this paper,the method of compre... Earthquake may cause severe damage to all kinds of bridge such as the falling down of the girder; therefore,effective measures should be employed to control the seismic displacement. In this paper,the method of comprehensive optimal control,com-bined with analytic hierarchy process,is employed to investigate the seismic response control of the Nanjing Jiangxinzhou Bridge,which is a single-tower self-anchored suspension bridge (SSSB). Also,3-dimensional nonlinear seismic response analyses are con-ducted. Three types of practical connection measures for seismic response control of SSSB are investigated,and the optimal pa-rameters of the connection devices are achieved by this method. Results show that both the elastic connection devices and the damp-ers with rational parameters can reduce the seismic displacement of the bridge effectively,but the elastic connection devices will in-crease the seismic force of the tower. When all factors are consid-ered,the optimal measure is by using the elastic connection devices and the dampers together. These results can provide references for seismic response control of SSSBs. 展开更多
关键词 self-anchored suspension bridge (SSSB) seismic response comprehensive optimal control single tower analytic hierarchy process (AHP) method
原文传递
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations——I:Theory 被引量:4
3
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第3期295-306,共12页
In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limita... In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limitations for installing the control device in the tower and the effect of varying natural frequency of the towers during construction. First, the finite element model of the bridge during its construction and the basic equation of motion of the MSPMD are introduced. The equation of motion of the bridge with the MSPMD under along-wind excitation is then established. Finally, a numerical simulation and parametric study are conducted to assess the effectiveness of the control system for reducing the wind-induced vibration of the bridge towers during construction. The numerical simulation results show that the MSPMD is practical and effective for reducing the along-wind response of the single column tower, can be installed in a small area of the tower, and complies with the time-variant characteristics of the bridge during its entire construction stage. 展开更多
关键词 multi-stage pendulum mass damper cable-stayed bridge single column tower wind-induced vibration
在线阅读 下载PDF
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations—Ⅱ: Experiment 被引量:2
4
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第4期417-424,共8页
The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this... The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this work. In this paper, the performance of the MSPMD for reducing bridge tower vibration is studied experimentally. A MSPMD model and a tower model of the bridge with geometry scaling of 1:100 were designed and manufactured. Calibration of the MSPMD model with different wire lengths is conducted to verify the analytical model of the damper. A series of tests for the uncontrolled freestanding tower, tower with cables, and tower with MSPMD model are then performed under harmonic and white noise excitations. The experimental results show that the responses of the tower model significantly decrease with the installation of the MSPMD model, which demonstrates the effectiveness of the M SPMD to mitigate the vibration of the bridge tower. 展开更多
关键词 experimental study cable-stayed bridge single column tower multi-stage pendulum mass damper vibration control
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部