Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum ...Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy.展开更多
This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400...This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method.展开更多
As wind power penetration has been gaining in the power grid for decades,a large number of the doubly fed induction generator(DFIG)based wind farms are being established around the globe.The power capacities of these ...As wind power penetration has been gaining in the power grid for decades,a large number of the doubly fed induction generator(DFIG)based wind farms are being established around the globe.The power capacities of these wind farms may vary around hundreds of MW,and most of the wind farms are connected to long transmission cables whose impedances can not be ignored and require careful attention.Several works have investigated the impedance interaction between the DFIG based wind farm and long transmission cables which may unfortunately cause high frequency resonance(HFR).The main contribution of this paper is to investigate the influence of the variable wind farm capacity on the behavior of the HFR when certain transmission cables are provided.It is found out that the potential HFR may happen in certain wind farms,and the larger wind farm capacity causes more severe HFR due to the relatively weaker grid transmission capability.Simulation results based on Matlab/Simulink are given to validate the analysis of HFR.展开更多
Based on the SinoMOS 1 μm 40 V CMOS process, a novel power factor corrention (PFC) converter with a low-power variable frequency function is presented. The circuit introduces a multi-vector error amplifier and a pr...Based on the SinoMOS 1 μm 40 V CMOS process, a novel power factor corrention (PFC) converter with a low-power variable frequency function is presented. The circuit introduces a multi-vector error amplifier and a programmable oscillator to achieve frequency modulation, which provides a rapid dynamic response and precise output voltage clamping with low power in the entire load. According to the external load variation, the system can modulate the circuit operating frequency linearly, thereby ensuring that the PFC converter can work in frequency conversionmode. Measured results show that the normal operating frequency of the PFC converter is 5-6 kHz, the start-up current is 36 μA, the stable operating current is only 2.43 mA, the efficiency is 97.3%, the power factor (PF) is 0.988, THD is 3.8%, the load adjust rate is 3%, and the linear adjust rate is less than 1%. Both theoretical and practical results reveal that the power consumption of the whole supply system is reduced efficiently, especially when the load varies. The active die area of the PFC converter chip is 1.61 ×1.52 mm^2.展开更多
In order to online monitor the running state of variable voltage and variable frequency(VVVF)hydraulic system,this paper presents a graphic monitoring method that fuses the information of variable frequency electric p...In order to online monitor the running state of variable voltage and variable frequency(VVVF)hydraulic system,this paper presents a graphic monitoring method that fuses the information of variable frequency electric parameters.This paper first analyzes how the voltage and current of the motor stator change with the operation conditions of VVVF hydraulic system.As a result,we draw the relationship between the electric parameters(voltage and current)and power frequency.Then,the signals of the voltage and current are fused as dynamic figures based on the idea of Lissajous figures,and the values of the electric parameters are related to the features of the dynamic figures.Rigorous theoretical analysis establishes the function between the electric power of the variable frequency motor(VFM)and the features of the plotted dynamic figures including area of diagram,area of bounding rectangle,tilt angle,etc.Finally,the effectiveness of the proposed method is verified by two cases,in which the speed of VFM and the load of VVVF hydraulic system are changed.The results show that the increase of the speed of VFM enhances its three-phase electric power,but reduces the tilt angle of the plotted dynamic figures.In addition,as the load of VVVF hydraulic system is increased,the three-phase electric power of VFM and the tilt angle of the plotted dynamic figures are both increased.This paper provides a new way to online monitor the running state of VVVF hydraulic system.展开更多
With an increasing penetration of wind power in the modern electrical grid, the increasing replacement of large conventional synchronous generators by wind power plants will potentially result in deteriorated frequenc...With an increasing penetration of wind power in the modern electrical grid, the increasing replacement of large conventional synchronous generators by wind power plants will potentially result in deteriorated frequency regulation performance due to the reduced system inertia and primary frequency response. A series of challenging issues arise from the aspects of power system planning,operation, control and protection. Therefore, it is valuable to develop variable speed wind turbines(VSWTs) equipped with frequency regulation capabilities that allow them to effectively participate in addressing severe frequency contingencies. This paper provides a comprehensive surveyon frequency regulation methods for VSWTs. It fully describes the concepts, principles and control strategies of prevailing frequency controls of VSWTs, including future development trends. It concludes with a performance comparison of frequency regulation by the four main types of wind power plants.展开更多
基金Funded by the National Natural Science Foundation of China(No.60974049)the Science and Technology Support Industrial Project of Jiangsu Province(No.BZ2008031,No.BE2008074,and No.BE2009090)+1 种基金the Nantong International Cooperative Project(No.W2009003)the Natural Science Foundation of Nantong University(No.08Z022 and No.08Z025).
文摘Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy.
基金supported by the Natural Science Foundation for Young Scientists of Shanxi Province,China(No.52007154).
文摘This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method.
文摘As wind power penetration has been gaining in the power grid for decades,a large number of the doubly fed induction generator(DFIG)based wind farms are being established around the globe.The power capacities of these wind farms may vary around hundreds of MW,and most of the wind farms are connected to long transmission cables whose impedances can not be ignored and require careful attention.Several works have investigated the impedance interaction between the DFIG based wind farm and long transmission cables which may unfortunately cause high frequency resonance(HFR).The main contribution of this paper is to investigate the influence of the variable wind farm capacity on the behavior of the HFR when certain transmission cables are provided.It is found out that the potential HFR may happen in certain wind farms,and the larger wind farm capacity causes more severe HFR due to the relatively weaker grid transmission capability.Simulation results based on Matlab/Simulink are given to validate the analysis of HFR.
基金supported by the National Natural Science Foundation of China(Nos.60676009,60776034)the Doctoral Foundation of Ministry of Education of China(No.20050701015)the National Outstanding Young Scientist Foundation of China(No.60725415).
文摘Based on the SinoMOS 1 μm 40 V CMOS process, a novel power factor corrention (PFC) converter with a low-power variable frequency function is presented. The circuit introduces a multi-vector error amplifier and a programmable oscillator to achieve frequency modulation, which provides a rapid dynamic response and precise output voltage clamping with low power in the entire load. According to the external load variation, the system can modulate the circuit operating frequency linearly, thereby ensuring that the PFC converter can work in frequency conversionmode. Measured results show that the normal operating frequency of the PFC converter is 5-6 kHz, the start-up current is 36 μA, the stable operating current is only 2.43 mA, the efficiency is 97.3%, the power factor (PF) is 0.988, THD is 3.8%, the load adjust rate is 3%, and the linear adjust rate is less than 1%. Both theoretical and practical results reveal that the power consumption of the whole supply system is reduced efficiently, especially when the load varies. The active die area of the PFC converter chip is 1.61 ×1.52 mm^2.
基金National Natural Science Foundation of China(No.51675399)
文摘In order to online monitor the running state of variable voltage and variable frequency(VVVF)hydraulic system,this paper presents a graphic monitoring method that fuses the information of variable frequency electric parameters.This paper first analyzes how the voltage and current of the motor stator change with the operation conditions of VVVF hydraulic system.As a result,we draw the relationship between the electric parameters(voltage and current)and power frequency.Then,the signals of the voltage and current are fused as dynamic figures based on the idea of Lissajous figures,and the values of the electric parameters are related to the features of the dynamic figures.Rigorous theoretical analysis establishes the function between the electric power of the variable frequency motor(VFM)and the features of the plotted dynamic figures including area of diagram,area of bounding rectangle,tilt angle,etc.Finally,the effectiveness of the proposed method is verified by two cases,in which the speed of VFM and the load of VVVF hydraulic system are changed.The results show that the increase of the speed of VFM enhances its three-phase electric power,but reduces the tilt angle of the plotted dynamic figures.In addition,as the load of VVVF hydraulic system is increased,the three-phase electric power of VFM and the tilt angle of the plotted dynamic figures are both increased.This paper provides a new way to online monitor the running state of VVVF hydraulic system.
基金supported in part by the National Natural Science Foundation of China (Nos.61428301,61433004 and 61627809)
文摘With an increasing penetration of wind power in the modern electrical grid, the increasing replacement of large conventional synchronous generators by wind power plants will potentially result in deteriorated frequency regulation performance due to the reduced system inertia and primary frequency response. A series of challenging issues arise from the aspects of power system planning,operation, control and protection. Therefore, it is valuable to develop variable speed wind turbines(VSWTs) equipped with frequency regulation capabilities that allow them to effectively participate in addressing severe frequency contingencies. This paper provides a comprehensive surveyon frequency regulation methods for VSWTs. It fully describes the concepts, principles and control strategies of prevailing frequency controls of VSWTs, including future development trends. It concludes with a performance comparison of frequency regulation by the four main types of wind power plants.