Objective To investigate the effect of multiple coatings of the one-step self-etching adhesive on immediate microtensile bond strength to primary dentin.Methods Twelve caries-free human primary molars were randomly di...Objective To investigate the effect of multiple coatings of the one-step self-etching adhesive on immediate microtensile bond strength to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 groups with 6 teeth each.In group 1,each tooth was hemisected into two halves.One half was assigned to control subgroup 1,which was bonded with a single-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 1 in which the adhesive was applied three times before light curing.In group 2,the teeth were also hemisected into two halves.One half was assigned to control subgroup 2,which was bonded with the single-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 2 in which three layers of adhesive were applied with light curing each successive layer.Microtensile bond strength was immediately tested after specimen preparation.Results When the adhesive was applied three times before light curing,the bond strength of the experimental subgroup 1(n=33,57.49±11.61 MPa) was higher than that of the control subgroup 1(n=31,49.71±11.43 MPa,P<0.05).When using the technique of applying multiple layers of adhesive with light curing each successive layer,no difference of immediate bond strength was observed between the control subgroup 2 and the experimental subgroup 2(P>0.05).Conclusion Multiple coatings of one-step self-etching adhesive can increase the immediate bond strength to primary dentin when using the technique of light-curing after applying three layers of adhesive.展开更多
Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin. Methods Twelve caries-free human primary molars were randomly divided into 2 gro...Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin. Methods Twelve caries-free human primary molars were randomly divided into 2 groups. In group 1, each tooth was hemisected into 2 halves. One half was assigned to the control subgroup 1, which was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instruc- tions; the other half was assigned to experimental subgroup 1, in which the adhesive was applied three times before light curing. In group 2, one split half tooth was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instructions; for the other half, three layers of adhesive were applied with each successive layer of light curing. Specimens were stored in 0.9% NaC1 containing 0.02% sodium azide at 37℃ for 18 months and then were subjected to microtensile bond strength test and the fracture mode analysis. Results When the adhesive was applied three times before light curing, the bond strength of the ex- perimental subgroup 1 was significantly higher than that of the control subgroup 1 (47.46__+13.91 vs. 38.12+11.21 MPa, P〈O.05). When using the technique of applying multiple layers of adhesive with each successive layer of light curing, no difference was observed in bond strength between the control subgroup and the experimental subgroup (39.40+8.87 vs. 40.87-+9.33 MPa, P〉O.05). Conclusion Multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin when using the technique of light-curing after applying 3 layers of adhesive.展开更多
Objectives: To quantitatively study the adhesive pro- perties of hepatoma cells to collagen Ⅳ coated artifi- cial basement membrane and to investigate the rele- vance of cell adhesive forces to the concentration of c...Objectives: To quantitatively study the adhesive pro- perties of hepatoma cells to collagen Ⅳ coated artifi- cial basement membrane and to investigate the rele- vance of cell adhesive forces to the concentration of collagen Ⅳ. Methods: Synchronous G1 and S phase cells were a- chieved using thymine-2-desoxyriboside and cochicine sequential blockage method and double thymine-2- desoxyriboside blockage method respectively. The adhesive forces of hepatoma cells were investigated by micropipette aspiration technique. Results: The adhesive forces of hepatoma cells to ar- tificial basement membrane were (107.78±65.44) ×10^(-10)N, (182.60±107.88)×10^(-10)N, (298.91± 144.13)×10^(-10)N when the concentration of the membrane coated by 1, 2, 5μg/ml collagen Ⅳ re- spectively (P<0.001). The adhesive forces of G1 and S phases hepatoma cells to artificial basement membrane were (275.86±232.80)×10^(-10)N and (161.16±120.40)×10^(-10)N respectively when the concentration of the membrane coated by 5μg/ml collagen Ⅳ (P<0.001). Conclusions: The adhesive forces of hepatoma cells to artifical basement membrane in direct proportion to the concentration of collagen Ⅳ suggests that the in- crease of basement membrane might be conducive to the chemotactic motion and adhesiveness of tumor cells. G1 phase cells are more capable of adhering to basement membrane than S phase cells. Hepatoma cells, especially G1 phase cells, may survive in blood circulation, and sequest and adhere in microcircula- tion, and get through basement membrane for re- mote metastasis.展开更多
This brief article reviews a very particular and quite narrowfield,namely what has been done and what is needed to know for tannin adhesives for wood panels to succeed industrially.The present fashionable focus on bio...This brief article reviews a very particular and quite narrowfield,namely what has been done and what is needed to know for tannin adhesives for wood panels to succeed industrially.The present fashionable focus on bioadhe-sives has led to producing chemical adhesive formulations and approaches for tannin adhesives as a subject of academic publications.These,as good and original they might be,are and will still remain a rather empty aca-demic exercise if not put to the test of real industrial trials and industrial use.They will remain so without the“little”secrets and techniques outlined here that show that there is a great gap between developing an adhesive formulation in the laboratory and the hard reality to make it work where it does really count,in its industrial application.It outlines the fact that even more modern and excellent,newly developed bioadhesive formulations might well miserably fail once tried in the industry if the problems that always arise in their upgrading are not identified and solved,and solved well.It also outlines the fact that not only must costs always be taken into account and that a practical and possibly easy-to-handle approach must always be used,but too expensive or complex and unyielding adhesive systems are also often shown to be unusable or unsuitable in industry.展开更多
Sn coatings were fabricated by mechanical coating technique for the first time. The coatings were characterized by XRD and SEM, among others. The SEM showed that the coatings had an irregular and uneven morphology. Th...Sn coatings were fabricated by mechanical coating technique for the first time. The coatings were characterized by XRD and SEM, among others. The SEM showed that the coatings had an irregular and uneven morphology. The influence of the rotation speed of planetary ball mill on the evolution and formation of the coatings was also investigated. The results indicated that continuous Sn coatings can be formed under a moderate rotation speed. In other words, the coatings cannot be formed when rotation speed was too high or too low. The evolution of the coatings was examined and discussed. The results showed that it followed the universal evolution law of metal coatings which included four stages. However, the exfoliation of the coatings was not seen even the milling time reached 30 h.展开更多
Arc-added glow discharge plasma penetrating technique is a new surface coating method. With the help of vacuum arc discharge, a cold cathode arc source continually emits ion beams of coating elements with high currenc...Arc-added glow discharge plasma penetrating technique is a new surface coating method. With the help of vacuum arc discharge, a cold cathode arc source continually emits ion beams of coating elements with high currency density and high ionizing ratio. As the ion bombard and diffusion working on, the surface of the parts form deposited layer, penetrated layer and hybrid layer. Under lab condition, a commercial magnesium alloy Az91 had been coated with Ti film layer with the aim of improving its’ anti-corrosion performance. This paper mainly summarized our studies on the testing and analyzing of the coating layer. The composition and microstructure of the coating layer had been analyzed by means of X-ray diffraction (XRD) and glow discharge spectrum (GDS), and the surface appearance had been surveyed by scanning electronic microscope (SEM). The adhesion strength between film and matrix had been evaluated by experiments of sticking-tearing. The results indicated that the coated layer on magnesium alloy were homogeneous, dense and robustly adhered.展开更多
Cellular mechanotransduction characterized by the transformation of mechanical stimuli into biochemical signals,represents a pivotal and complex process underpinning a multitude of cellular functionalities.This proces...Cellular mechanotransduction characterized by the transformation of mechanical stimuli into biochemical signals,represents a pivotal and complex process underpinning a multitude of cellular functionalities.This process is integral to diverse biological phenomena,including embryonic development,cell migration,tissue regeneration,and disease pathology,particularly in the context of cancer metastasis and cardiovascular diseases.Despite the profound biological and clinical significance of mechanotransduction,our understanding of this complex process remains incomplete.The recent development of advanced optical techniques enables in-situ force measurement and subcellular manipulation from the outer cell membrane to the organelles inside a cell.In this review,we delved into the current state-of-the-art techniques utilized to probe cellular mechanobiology,their principles,applications,and limitations.We mainly examined optical methodologies to quantitatively measure the mechanical properties of cells during intracellular transport,cell adhesion,and migration.We provided an introductory overview of various conventional and optical-based techniques for probing cellular mechanics.These techniques have provided into the dynamics of mechanobiology,their potential to unravel mechanistic intricacies and implications for therapeutic intervention.展开更多
BACKGROUND Intraabdominal adhesions develop spontaneously or after an inflammatory process or surgical procedure in the abdomen.They are the most common cause of small bowel obstruction(SBO).SBO occasionally leads to ...BACKGROUND Intraabdominal adhesions develop spontaneously or after an inflammatory process or surgical procedure in the abdomen.They are the most common cause of small bowel obstruction(SBO).SBO occasionally leads to intestinal ischemia(In Is)which can be a life-threatening condition that requires management as soon as possible.We herein report a case of SBO with In Is presented in our institution and treated without intestinal resection.CASE SUMMARY A 34-year-old man presented at the emergency department after a 12-h-onset diffuse abdominal pain,bloating and nausea.He had a history of traumatic right hepatectomy 11 years ago as well as adhesiolysis and resection of a long part of small bowel 2 years ago.An abdominal computed tomography(CT)showed dilated loops that led to the diagnosis of SBO.Due to deteriorating lactic acidosis,the patient was operated.Torsion of the small bowel around an adhesion led to2.30 m of ischemic ileum.After the application of N/S 40°C for 20 min,the intestine showed signs of improvement and it was decided to avoid resection and instead temporary close the abdomen with vacuum-pack technique.At the second-look laparotomy 48 h later,the intestine appeared normal.The patient was discharged on the 8 th post-op day in excellent condition.CONCLUSION In case of SBO caused by adhesions,extreme caution is needed if In Is is present,as the clinical signs are mild and you should rely for diagnosis in CT findings and lactate levels.Conservative surgical approach could reverse the effects of In Is,if performed quickly,so that intestinal resection is avoided and should be used even when minimum signs of viability are present.展开更多
Pulp capping is one of the solving for keeping vital pulp in the case of dentin caries,reversible pulpitis or traumatic pulp exposure.The presence of bacteria on the cavity walls or in the pulp was the major factor th...Pulp capping is one of the solving for keeping vital pulp in the case of dentin caries,reversible pulpitis or traumatic pulp exposure.The presence of bacteria on the cavity walls or in the pulp was the major factor that leads to the failure of pulp capping.Traditional pulp capping agent,calcium hydroxide,may not prevent microleakage.Selfetching system is a newly developed adhesive system,which could provide less microleakage and would not break down or dissolve,preventing the oral fluids and bacteria from the pulp along the cavity wall.This may reduce such clinical problems as postoperative sensitivity,secondary caries and marginal discoloration.Researches showed that some kinds of self-etching adhesives induced the mild to moderate inflammatory pulp response,with negative bacterial staining.Inclusion of antibacterial components into self-etching system,such as 12-methacryloyloxydodecylpyridinium bromide(MDPB)may inhibit bacteria and provide better clinical effects.It is speculated that using the self-etching adhesive system containing the antibacterial agent,such as MDPB,to the dental pulp directly or indirectly,may inhibit bacteria after the placement of restoration as well as residual bacteria in the cavity.展开更多
文摘Objective To investigate the effect of multiple coatings of the one-step self-etching adhesive on immediate microtensile bond strength to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 groups with 6 teeth each.In group 1,each tooth was hemisected into two halves.One half was assigned to control subgroup 1,which was bonded with a single-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 1 in which the adhesive was applied three times before light curing.In group 2,the teeth were also hemisected into two halves.One half was assigned to control subgroup 2,which was bonded with the single-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 2 in which three layers of adhesive were applied with light curing each successive layer.Microtensile bond strength was immediately tested after specimen preparation.Results When the adhesive was applied three times before light curing,the bond strength of the experimental subgroup 1(n=33,57.49±11.61 MPa) was higher than that of the control subgroup 1(n=31,49.71±11.43 MPa,P<0.05).When using the technique of applying multiple layers of adhesive with light curing each successive layer,no difference of immediate bond strength was observed between the control subgroup 2 and the experimental subgroup 2(P>0.05).Conclusion Multiple coatings of one-step self-etching adhesive can increase the immediate bond strength to primary dentin when using the technique of light-curing after applying three layers of adhesive.
文摘Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin. Methods Twelve caries-free human primary molars were randomly divided into 2 groups. In group 1, each tooth was hemisected into 2 halves. One half was assigned to the control subgroup 1, which was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instruc- tions; the other half was assigned to experimental subgroup 1, in which the adhesive was applied three times before light curing. In group 2, one split half tooth was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instructions; for the other half, three layers of adhesive were applied with each successive layer of light curing. Specimens were stored in 0.9% NaC1 containing 0.02% sodium azide at 37℃ for 18 months and then were subjected to microtensile bond strength test and the fracture mode analysis. Results When the adhesive was applied three times before light curing, the bond strength of the ex- perimental subgroup 1 was significantly higher than that of the control subgroup 1 (47.46__+13.91 vs. 38.12+11.21 MPa, P〈O.05). When using the technique of applying multiple layers of adhesive with each successive layer of light curing, no difference was observed in bond strength between the control subgroup and the experimental subgroup (39.40+8.87 vs. 40.87-+9.33 MPa, P〉O.05). Conclusion Multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin when using the technique of light-curing after applying 3 layers of adhesive.
基金This work was supported by a grant from the National Natural Science Foundation of China (No. 39500037).
文摘Objectives: To quantitatively study the adhesive pro- perties of hepatoma cells to collagen Ⅳ coated artifi- cial basement membrane and to investigate the rele- vance of cell adhesive forces to the concentration of collagen Ⅳ. Methods: Synchronous G1 and S phase cells were a- chieved using thymine-2-desoxyriboside and cochicine sequential blockage method and double thymine-2- desoxyriboside blockage method respectively. The adhesive forces of hepatoma cells were investigated by micropipette aspiration technique. Results: The adhesive forces of hepatoma cells to ar- tificial basement membrane were (107.78±65.44) ×10^(-10)N, (182.60±107.88)×10^(-10)N, (298.91± 144.13)×10^(-10)N when the concentration of the membrane coated by 1, 2, 5μg/ml collagen Ⅳ re- spectively (P<0.001). The adhesive forces of G1 and S phases hepatoma cells to artificial basement membrane were (275.86±232.80)×10^(-10)N and (161.16±120.40)×10^(-10)N respectively when the concentration of the membrane coated by 5μg/ml collagen Ⅳ (P<0.001). Conclusions: The adhesive forces of hepatoma cells to artifical basement membrane in direct proportion to the concentration of collagen Ⅳ suggests that the in- crease of basement membrane might be conducive to the chemotactic motion and adhesiveness of tumor cells. G1 phase cells are more capable of adhering to basement membrane than S phase cells. Hepatoma cells, especially G1 phase cells, may survive in blood circulation, and sequest and adhere in microcircula- tion, and get through basement membrane for re- mote metastasis.
文摘This brief article reviews a very particular and quite narrowfield,namely what has been done and what is needed to know for tannin adhesives for wood panels to succeed industrially.The present fashionable focus on bioadhe-sives has led to producing chemical adhesive formulations and approaches for tannin adhesives as a subject of academic publications.These,as good and original they might be,are and will still remain a rather empty aca-demic exercise if not put to the test of real industrial trials and industrial use.They will remain so without the“little”secrets and techniques outlined here that show that there is a great gap between developing an adhesive formulation in the laboratory and the hard reality to make it work where it does really count,in its industrial application.It outlines the fact that even more modern and excellent,newly developed bioadhesive formulations might well miserably fail once tried in the industry if the problems that always arise in their upgrading are not identified and solved,and solved well.It also outlines the fact that not only must costs always be taken into account and that a practical and possibly easy-to-handle approach must always be used,but too expensive or complex and unyielding adhesive systems are also often shown to be unusable or unsuitable in industry.
文摘Sn coatings were fabricated by mechanical coating technique for the first time. The coatings were characterized by XRD and SEM, among others. The SEM showed that the coatings had an irregular and uneven morphology. The influence of the rotation speed of planetary ball mill on the evolution and formation of the coatings was also investigated. The results indicated that continuous Sn coatings can be formed under a moderate rotation speed. In other words, the coatings cannot be formed when rotation speed was too high or too low. The evolution of the coatings was examined and discussed. The results showed that it followed the universal evolution law of metal coatings which included four stages. However, the exfoliation of the coatings was not seen even the milling time reached 30 h.
文摘Arc-added glow discharge plasma penetrating technique is a new surface coating method. With the help of vacuum arc discharge, a cold cathode arc source continually emits ion beams of coating elements with high currency density and high ionizing ratio. As the ion bombard and diffusion working on, the surface of the parts form deposited layer, penetrated layer and hybrid layer. Under lab condition, a commercial magnesium alloy Az91 had been coated with Ti film layer with the aim of improving its’ anti-corrosion performance. This paper mainly summarized our studies on the testing and analyzing of the coating layer. The composition and microstructure of the coating layer had been analyzed by means of X-ray diffraction (XRD) and glow discharge spectrum (GDS), and the surface appearance had been surveyed by scanning electronic microscope (SEM). The adhesion strength between film and matrix had been evaluated by experiments of sticking-tearing. The results indicated that the coated layer on magnesium alloy were homogeneous, dense and robustly adhered.
基金the funding from Start-up Fundings of Ocean University of China(862401013154 and 862401013155)Laboratory for Marine Drugs and Bioproducts Qingdao Marine Science and Technology Center(LMDBCXRC202401 and LMDBCXRC202402)+1 种基金Taishan Scholar Youth Expert Program of Shandong Province(tsqn202306102 and tsqn202312105)Shandong Provincial Overseas Excellent Young Scholar Program(2024HWYQ-042 and 2024HWYQ-043)for supporting this work.
文摘Cellular mechanotransduction characterized by the transformation of mechanical stimuli into biochemical signals,represents a pivotal and complex process underpinning a multitude of cellular functionalities.This process is integral to diverse biological phenomena,including embryonic development,cell migration,tissue regeneration,and disease pathology,particularly in the context of cancer metastasis and cardiovascular diseases.Despite the profound biological and clinical significance of mechanotransduction,our understanding of this complex process remains incomplete.The recent development of advanced optical techniques enables in-situ force measurement and subcellular manipulation from the outer cell membrane to the organelles inside a cell.In this review,we delved into the current state-of-the-art techniques utilized to probe cellular mechanobiology,their principles,applications,and limitations.We mainly examined optical methodologies to quantitatively measure the mechanical properties of cells during intracellular transport,cell adhesion,and migration.We provided an introductory overview of various conventional and optical-based techniques for probing cellular mechanics.These techniques have provided into the dynamics of mechanobiology,their potential to unravel mechanistic intricacies and implications for therapeutic intervention.
文摘BACKGROUND Intraabdominal adhesions develop spontaneously or after an inflammatory process or surgical procedure in the abdomen.They are the most common cause of small bowel obstruction(SBO).SBO occasionally leads to intestinal ischemia(In Is)which can be a life-threatening condition that requires management as soon as possible.We herein report a case of SBO with In Is presented in our institution and treated without intestinal resection.CASE SUMMARY A 34-year-old man presented at the emergency department after a 12-h-onset diffuse abdominal pain,bloating and nausea.He had a history of traumatic right hepatectomy 11 years ago as well as adhesiolysis and resection of a long part of small bowel 2 years ago.An abdominal computed tomography(CT)showed dilated loops that led to the diagnosis of SBO.Due to deteriorating lactic acidosis,the patient was operated.Torsion of the small bowel around an adhesion led to2.30 m of ischemic ileum.After the application of N/S 40°C for 20 min,the intestine showed signs of improvement and it was decided to avoid resection and instead temporary close the abdomen with vacuum-pack technique.At the second-look laparotomy 48 h later,the intestine appeared normal.The patient was discharged on the 8 th post-op day in excellent condition.CONCLUSION In case of SBO caused by adhesions,extreme caution is needed if In Is is present,as the clinical signs are mild and you should rely for diagnosis in CT findings and lactate levels.Conservative surgical approach could reverse the effects of In Is,if performed quickly,so that intestinal resection is avoided and should be used even when minimum signs of viability are present.
文摘Pulp capping is one of the solving for keeping vital pulp in the case of dentin caries,reversible pulpitis or traumatic pulp exposure.The presence of bacteria on the cavity walls or in the pulp was the major factor that leads to the failure of pulp capping.Traditional pulp capping agent,calcium hydroxide,may not prevent microleakage.Selfetching system is a newly developed adhesive system,which could provide less microleakage and would not break down or dissolve,preventing the oral fluids and bacteria from the pulp along the cavity wall.This may reduce such clinical problems as postoperative sensitivity,secondary caries and marginal discoloration.Researches showed that some kinds of self-etching adhesives induced the mild to moderate inflammatory pulp response,with negative bacterial staining.Inclusion of antibacterial components into self-etching system,such as 12-methacryloyloxydodecylpyridinium bromide(MDPB)may inhibit bacteria and provide better clinical effects.It is speculated that using the self-etching adhesive system containing the antibacterial agent,such as MDPB,to the dental pulp directly or indirectly,may inhibit bacteria after the placement of restoration as well as residual bacteria in the cavity.