Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering case...Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering cases,the effectiveness of the analogue test method is verified by comparing it with the traditional anchor pile method and self-balanced method.Taking the self-balanced test of the bridge pile foundation in the Songhua River as an example,the conversion factor of sandy soil and weathered mudstone are confirmed by the analogue test method.The results show that the conversion factor of sandy soil and weathered mudstone in the Songhua River area should consider the geological conditions and the construction technology,etc.The standard values are relatively conservative.It is suggested that the engineering application should be properly revised.The recommended range of the conversion factor of sandy soil in this area is 0.65 to 0.85,and that of weathered mudstone is 1.0.展开更多
Stress waves propagate along vertical,radial and circumferential directions when a non-uniformly distributed load is applied at one end of a three-dimensional shaft.As a result,the receiving signals are usually mixed ...Stress waves propagate along vertical,radial and circumferential directions when a non-uniformly distributed load is applied at one end of a three-dimensional shaft.As a result,the receiving signals are usually mixed with undesired interference components,often featuring as high-frequency fluctuations.Previous studies have revealed that sectional geometry(shape and size)greatly affects the high-frequency interference.In this study,low strain dynamic testing on full-scale X-section concrete is conducted in order to investigate the influences of high-frequency interference on velocity responses at the pile head.Emphasis is placed on the frequency and peak value of interference waves at various receiving points.Additionally,the effects of the geometrical,and mechanical properties of the pile shaft on high-frequency interference are elaborated on through the three-dimensional finite element method.The results show that the measured wave is obscured by interference waves superposed by two types of high-frequency components.The modulus and cross-sectional area are contributing factors to the frequency and peak value of the interference waves.On the other hand,the position with the least interference is determined,to some extent,by the accurate shape of the X-section.展开更多
The measurement of pile axial load is of great significance to determining pile foundation design parameters such as skin friction and end bearing capacity and analyzing load transfer mechanisms.Affected by the temper...The measurement of pile axial load is of great significance to determining pile foundation design parameters such as skin friction and end bearing capacity and analyzing load transfer mechanisms.Affected by the temperature and ice content of frozen ground,the interface contact relationship between pile foundation and frozen soil is complicated,making pile axial load measurements more uncertain than that in non-frozen ground.Therefore,it is necessary to gain an in-depth understanding of the current pile axial load test methods.Four methods are systematically reviewed:vibrating wire sensors,strain gauges,sliding micrometers,and optical fiber strain sensors.At the same time,the applicability of the four test methods in frozen soil regions is discussed in detail.The first two methods are mature and commonly used.The sliding micrometer is only suitable for short-term measurement.While the Fiber Bragg grating(FBG)strain gauge meets the monitoring requirements,the Brillouin optical time-domain reflectometer(BOTDR)needs further verification.This paper aims to provide a technical reference for selecting and applying different methods in the pile axial load test for the stability study and bearing capacity assessment of pile foundations in cold regions.展开更多
Topography effects on the vertical vibration responses of pile group are revealed though numerical analysis and model tests.First,a series of model tests with different topography of ground and bedrock are conducted.T...Topography effects on the vertical vibration responses of pile group are revealed though numerical analysis and model tests.First,a series of model tests with different topography of ground and bedrock are conducted.The results indicate that displacement amplitude of the pile head in sloping ground topography is larger than in horizontal ground.Differential displacement at various positions of the pile cap is observed in non-horizontal topography.Afterwards,a numerical algorithm is employed to further explore the essential response characteristics in group piles of different topography configurations,which has been verified by the test results.The lengths of the exposed and frictional segment,together with the thickness of the subsoil layer,are the dominant factors which cause non-axisymmetric vibration at the pile cap.展开更多
This work presents a new analytical method to analyze the influence of reaction piles on the test pile response in a static load test.In our method,the interactive effect between soil and pile is simulated using indep...This work presents a new analytical method to analyze the influence of reaction piles on the test pile response in a static load test.In our method,the interactive effect between soil and pile is simulated using independent springs and the shear displacement method is adopted to analyze the influence of reaction piles on test pile response.Moreover,the influence of the sheltering effect between reaction piles and test pile on the test pile response is taken into account.Two cases are analyzed to verify the rationality and efficiency of the present method.This method can be easily extended to a nonlinear response of an influenced test pile embedded in a multilayered soil,and the validity is also demonstrated using centrifuge model tests and a computer program presented in the literature.The present analyses indicate that the proposed method will lead to an underestimation of the test pile settlement in a static load test if the influence of the presence of reaction piles on the test pile response is neglected.展开更多
This study proposes a deep learning-based approach for shaft resistance evaluation of cast-in-site piles on reclaimed ground,independent of theoretical hypotheses and engineering experience.A series of field tests was...This study proposes a deep learning-based approach for shaft resistance evaluation of cast-in-site piles on reclaimed ground,independent of theoretical hypotheses and engineering experience.A series of field tests was first performed to investigate the characteristics of the shaft resistance of cast-in-site piles on reclaimed ground.Then,an intelligent approach based on the long short term memory deep-learning technique was proposed to calculate the shaft resistance of the cast-in-site pile.The proposed method allows accurate estimation of the shaft resistance of cast-in-site piles,not only under the ultimate load but also under the working load.Comparisons with empirical methods confirmed the effectiveness of the proposed method for the shaft resistance estimation of cast-in-site piles on reclaimed ground in offshore areas.展开更多
A new construction method of pile foundation in composite ground, in which, prior to installing piles, the ground is improved around the heads of the piles in soft ground or ground subject to liquefaction, which is in...A new construction method of pile foundation in composite ground, in which, prior to installing piles, the ground is improved around the heads of the piles in soft ground or ground subject to liquefaction, which is introduced in this paper. This construction method uses a combination of pile foundation construction together with common ground improvement methods, including deep mixing, preloading and sand compaction piling, and it is referred to as the composite ground pile method. Since an artificial ground with relatively high rigidity comparing with that of the original ground was formed around the pile in this method, and the seismic performance has not been made clear, thus the seismic performance of piles in composite ground was systematically analyzed through a series of centrifuge model tests and numerical analyses by using dynamic nonlinear finite element method, and a verification method for the seismic performance of piles in composite ground was proposed on the basis of the experimental and numerical results.展开更多
In the process of elaboration, the acoustic transmission method is used to detect the defective model piles with different media types, and the acoustic parameters and data after the test are qualitatively analyzed, s...In the process of elaboration, the acoustic transmission method is used to detect the defective model piles with different media types, and the acoustic parameters and data after the test are qualitatively analyzed, so as to preliminarily determine the type of defective media. It is hoped that through the corresponding case analysis, it can provide a certain practical reference for the pile detection work of acoustic transmission method and provide a certain reference for the qualitative analysis of pile inspectors.展开更多
基金The National Key Research and Development Program(No.2017YFC0703408)the National Natural Science Foundation of China(No.51478109,51678145,51878160)
文摘Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering cases,the effectiveness of the analogue test method is verified by comparing it with the traditional anchor pile method and self-balanced method.Taking the self-balanced test of the bridge pile foundation in the Songhua River as an example,the conversion factor of sandy soil and weathered mudstone are confirmed by the analogue test method.The results show that the conversion factor of sandy soil and weathered mudstone in the Songhua River area should consider the geological conditions and the construction technology,etc.The standard values are relatively conservative.It is suggested that the engineering application should be properly revised.The recommended range of the conversion factor of sandy soil in this area is 0.65 to 0.85,and that of weathered mudstone is 1.0.
基金National Natural Science Foundation of China under Grant Nos.51622803 and 51878103China Postdoctoral Science Foundation under Grant No.2021M692689。
文摘Stress waves propagate along vertical,radial and circumferential directions when a non-uniformly distributed load is applied at one end of a three-dimensional shaft.As a result,the receiving signals are usually mixed with undesired interference components,often featuring as high-frequency fluctuations.Previous studies have revealed that sectional geometry(shape and size)greatly affects the high-frequency interference.In this study,low strain dynamic testing on full-scale X-section concrete is conducted in order to investigate the influences of high-frequency interference on velocity responses at the pile head.Emphasis is placed on the frequency and peak value of interference waves at various receiving points.Additionally,the effects of the geometrical,and mechanical properties of the pile shaft on high-frequency interference are elaborated on through the three-dimensional finite element method.The results show that the measured wave is obscured by interference waves superposed by two types of high-frequency components.The modulus and cross-sectional area are contributing factors to the frequency and peak value of the interference waves.On the other hand,the position with the least interference is determined,to some extent,by the accurate shape of the X-section.
基金This study was supported by the Strategic Priority Research Program of the Chinese Academy of Science(Grant No.XDA20020102)Science and Technology Project of State Grid Corporation of China(Contract No.SGQHDKYOSBJS201600077)+1 种基金National Natural Science Foundation of China(Grant No.41101065)the State Key Laboratory of Frozen Soil Engineering Foundation(Grant No.SKLFSE-ZT-34)。
文摘The measurement of pile axial load is of great significance to determining pile foundation design parameters such as skin friction and end bearing capacity and analyzing load transfer mechanisms.Affected by the temperature and ice content of frozen ground,the interface contact relationship between pile foundation and frozen soil is complicated,making pile axial load measurements more uncertain than that in non-frozen ground.Therefore,it is necessary to gain an in-depth understanding of the current pile axial load test methods.Four methods are systematically reviewed:vibrating wire sensors,strain gauges,sliding micrometers,and optical fiber strain sensors.At the same time,the applicability of the four test methods in frozen soil regions is discussed in detail.The first two methods are mature and commonly used.The sliding micrometer is only suitable for short-term measurement.While the Fiber Bragg grating(FBG)strain gauge meets the monitoring requirements,the Brillouin optical time-domain reflectometer(BOTDR)needs further verification.This paper aims to provide a technical reference for selecting and applying different methods in the pile axial load test for the stability study and bearing capacity assessment of pile foundations in cold regions.
基金National Science Foundation of China under Grant Nos.51622803 and 51778092Innovation Group Science Foundation of the Natural Science Foundation of Chongqing,China under Grant No.cstc2020jcyjcxttX0003China Scholarship Council(File No:201806050121)for financial support to visit Purdue University。
文摘Topography effects on the vertical vibration responses of pile group are revealed though numerical analysis and model tests.First,a series of model tests with different topography of ground and bedrock are conducted.The results indicate that displacement amplitude of the pile head in sloping ground topography is larger than in horizontal ground.Differential displacement at various positions of the pile cap is observed in non-horizontal topography.Afterwards,a numerical algorithm is employed to further explore the essential response characteristics in group piles of different topography configurations,which has been verified by the test results.The lengths of the exposed and frictional segment,together with the thickness of the subsoil layer,are the dominant factors which cause non-axisymmetric vibration at the pile cap.
基金Project supported by the China Postdoctoral Science Foundation (No. 2012M521339)the Independent Innovation Foundation of Shandong University (No. 2012GN012),China
文摘This work presents a new analytical method to analyze the influence of reaction piles on the test pile response in a static load test.In our method,the interactive effect between soil and pile is simulated using independent springs and the shear displacement method is adopted to analyze the influence of reaction piles on test pile response.Moreover,the influence of the sheltering effect between reaction piles and test pile on the test pile response is taken into account.Two cases are analyzed to verify the rationality and efficiency of the present method.This method can be easily extended to a nonlinear response of an influenced test pile embedded in a multilayered soil,and the validity is also demonstrated using centrifuge model tests and a computer program presented in the literature.The present analyses indicate that the proposed method will lead to an underestimation of the test pile settlement in a static load test if the influence of the presence of reaction piles on the test pile response is neglected.
基金the Research Funding of Shantou University for New Faculty Member(No.NTF19024-2019)the National Nature Science Foundation of China(No.41372283)。
文摘This study proposes a deep learning-based approach for shaft resistance evaluation of cast-in-site piles on reclaimed ground,independent of theoretical hypotheses and engineering experience.A series of field tests was first performed to investigate the characteristics of the shaft resistance of cast-in-site piles on reclaimed ground.Then,an intelligent approach based on the long short term memory deep-learning technique was proposed to calculate the shaft resistance of the cast-in-site pile.The proposed method allows accurate estimation of the shaft resistance of cast-in-site piles,not only under the ultimate load but also under the working load.Comparisons with empirical methods confirmed the effectiveness of the proposed method for the shaft resistance estimation of cast-in-site piles on reclaimed ground in offshore areas.
文摘A new construction method of pile foundation in composite ground, in which, prior to installing piles, the ground is improved around the heads of the piles in soft ground or ground subject to liquefaction, which is introduced in this paper. This construction method uses a combination of pile foundation construction together with common ground improvement methods, including deep mixing, preloading and sand compaction piling, and it is referred to as the composite ground pile method. Since an artificial ground with relatively high rigidity comparing with that of the original ground was formed around the pile in this method, and the seismic performance has not been made clear, thus the seismic performance of piles in composite ground was systematically analyzed through a series of centrifuge model tests and numerical analyses by using dynamic nonlinear finite element method, and a verification method for the seismic performance of piles in composite ground was proposed on the basis of the experimental and numerical results.
文摘In the process of elaboration, the acoustic transmission method is used to detect the defective model piles with different media types, and the acoustic parameters and data after the test are qualitatively analyzed, so as to preliminarily determine the type of defective media. It is hoped that through the corresponding case analysis, it can provide a certain practical reference for the pile detection work of acoustic transmission method and provide a certain reference for the qualitative analysis of pile inspectors.