期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Analysis of phacoemulsification parameters and anterior segment parameters in cataract patients with different blood glucose levels
1
作者 Xu Xinqi Wang Ping +5 位作者 Liu Tong Wang Lei Zhu Xuansheng Zhang Huiwen Shi Lei Gao Wen 《国际眼科杂志》 2025年第6期875-885,共11页
AIM:To analyze the characteristics and correlation of phacoemulsification parameters and anterior segment parameters in cataract patients with different blood glucose levels.METHODS:A total of 45 type 2 diabetic catar... AIM:To analyze the characteristics and correlation of phacoemulsification parameters and anterior segment parameters in cataract patients with different blood glucose levels.METHODS:A total of 45 type 2 diabetic cataract patients(45 eyes)treated in our hospital from March 2023 to April 2024 were stratified into two groups based on glycosylated hemoglobin(HbA1c)levels:group A:HbA1c<7%(n=18)and group B:7%≤HbA1c<8.5%(n=27);a total of 94 age-matched age-related cataract patients(94 eyes)were enrolled as the control group(group C).All underwent phacoemulsification with intraocular lens implantation.Anterior segment parameters,including corneal,lens and anterior chamber measurements,were recorded.Correlations between phacoemulsification parameters and anterior segment parameters were analyzed,and differences among groups were compared.RESULTS:In groups A and B,effective phacoemulsification time(EPT)negatively correlated with corneal endothelial cell density(CECD)(r=-0.315,P=0.035).Average phacoemulsification time(APT)positively correlated with the anterior corneal surface radius of curvature(Rm;r=0.402,P=0.006)and negatively correlated with the flat axis meridian curvature(K 1),steep axis meridian curvature(K 2),mean curvature(Km)of the anterior corneal surface,and lens density at 6 mm zones(PDZ3;all P<0.05).Average phacoemulsification energy(AVE)positively correlated with mean lens density(LD-mean),lens density at 2 mm zones(PDZ1),lens density at 4 mm zones(PDZ2),and PDZ3(all P<0.05),and negatively with pupil diameter(r=-0.385,P=0.009).In the group C,EPT showed a positive correlation with Pentacam nucleus staging(PNS)density grade,PDZ1,PDZ2,and PDZ3(all P<0.05).A positive correlation was observed between AVE and PNS classification(r=0.246,P=0.018).Conversely,AVE exhibited a negative correlation with CECD(r=-0.245,P=0.018).EPT in groups A and B was higher than that in the group C(P<0.05).Both EPT and APT in the group B were higher than those in the group A(P<0.05).In diabetic cataract patients,CECD,corneal density(CD),and posterior corneal surface height positively correlated with diabetes duration(P<0.05).Posterior corneal surface K 1 and Rm positively correlated with 7%≤HbA1c<8.5%(P<0.05).Total corneal astigmatism negatively correlated with HbA1c,2-hour post-breakfast blood glucose(2hPBG),and fasting insulin(FINS;P<0.05).CD and lens thickness(LT)positively correlated with FINS(P<0.05).CONCLUSION:Phacoemulsification parameters and blood glucose-related indices exhibited varying degrees of correlation with anterior segment parameters in cataract patients with different blood glucose levels.EPT in diabetic cataract patients was higher than that in age-related cataract patients,while EPT and APT in diabetic cataract patients with poor glycemic control were higher than those with good glycemic control. 展开更多
关键词 diabetic cataract effective phacoemulsification time average phacoemulsification energy average phacoemulsification time anterior segment parameter
暂未订购
Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas 被引量:8
2
作者 Gabor Nemeth Eszter Szalai +3 位作者 Ziad Hassan Agnes Lipecz Zsuzsa Flasko Laszlo Modis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期217-222,共6页
AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using th... AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye. 展开更多
关键词 anterior segment parameters biomechan-ics corneal visualization Scheimpflug technology OcularResponse Analyzer
原文传递
Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting 被引量:6
3
作者 Jin-Soo Kim Jung Yeol Choi +2 位作者 Ji-Won Kwon Won Ryang Wee Young Keun Han 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期235-239,共5页
AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet(Nd:YAG) laser posterior capsulotomy with vitreous strand cuttingMETHODS: A total of 40 eyes of 37 patients with symptomatic poste... AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet(Nd:YAG) laser posterior capsulotomy with vitreous strand cuttingMETHODS: A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity(PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting(modified round pattern). The best corrected visual acuity(BCVA), intraocular pressure(IOP), refractive error, endothelial cell count(ECC), anterior segment parameters, including anterior chamber depth(ACD) and anterior chamber angle(ACA) were measured before and 1 mo after the laser posterior capsulotomy. RESULTS: In both groups, the BCVA improved significantly(P〈0.001 for the modified round pattern group, P=0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased(P〈0.001 for both) and the ACA significantly increased(P=0.001 for the modified round pattern group and P=0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups.CONCLUSION: Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO. 展开更多
关键词 posterior capsulotomy modified round pattern vitreous strand cutting anterior segment parameter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部