The full magnetic gradient tensor (MGT) refers to the spatial change rate of the three field components of the geomagnetic field vector along three mutually orthogonal axes. The tensor is of use to geological mappin...The full magnetic gradient tensor (MGT) refers to the spatial change rate of the three field components of the geomagnetic field vector along three mutually orthogonal axes. The tensor is of use to geological mapping, resources exploration, magnetic navigation, and others. However, it is very difficult to measure the full magnetic tensor gradient using existing engineering technology. We present a method to use triaxial aeromagnetic gradient measurements for deriving the full MGT. The method uses the triaxial gradient data and makes full use of the variation of the magnetic anomaly modulus in three dimensions to obtain a self-consistent magnetic tensor gradient. Numerical simulations show that the full MGT data obtained with the proposed method are of high precision and satisfy the requirements of data processing. We selected triaxial aeromagnetic gradient data from the Hebei Province for calculating the full MGT. Data processing shows that using triaxial tensor gradient data allows to take advantage of the spatial rate of change of the total field in three dimensions and suppresses part of the independent noise in the aeromagnetic gradient. The calculated tensor components have improved resolution, and the transformed full tensor gradient satisfies the requirement of geological mapping and interpretation.展开更多
Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tens...Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tensor, field differentiation is generally approximated by field difference. As a result, magnetic objects positioning by magnetic field gradient tensor measurement always involves an inherent error caused by sensor sizes, leading to a reduction in detectable distance and detectable angle. In this paper, the inherent positioning error caused by magnetic field gradient tensor measurement is calculated and corrected by iterations based on the systematic position error distribution patterns. The results show that, the detectable distance range and the angle range of an ac magnetic object(2.44 Am^2@1 kHz) can be increased from(0.45 m, 0.75 m),(0?, 25?) to(0.30 m, 0.80 m),(0?,80?), respectively.展开更多
Compared to conventional magnetic data,magnetic gradient tensor data contain more high-frequency signal components,which can better describe the features of geological bodies.The directional analytic signal of the mag...Compared to conventional magnetic data,magnetic gradient tensor data contain more high-frequency signal components,which can better describe the features of geological bodies.The directional analytic signal of the magnetic gradient tensor is not easily interfered from the tilting magnetization,but it can infer the range of the fi eld source more accurately.However,the analytic signal strength decays faster with depth,making it diffi cult to identify deep fi eld sources.Balanced-boundary recognition can eff ectively overcome this disadvantage.We present here a balanced-boundary identifi cation technique based on the normalization of three-directional analytic signals from aeromagnetic gradient tensor data.This method can eff ectively prevent the fast attenuation of analytic signals.We also derive an Euler inversion algorithm of three-directional analytic signal derivative.By combining magnetic-anomaly model testing with the traditional magnetic anomaly interpretation method,we show that the boundary-recognition technology based on a magnetic gradient tensor analytic signal has a greater advantage in identifying the boundaries of the geological body and can better refl ect shallow anomalies.The characteristics of the Euler equation based on the magnetic anomaly direction to resolve the signal derivative have better convergence,and the obtained solution is more concentrated,which can obtain the depth and horizontal range information of the geological body more accurately.Applying the above method to the measured magneticanomaly gradient data from Baoding area,more accurate fi eld source information is obtained,which shows the feasibility of applying this method to geological interpretations.展开更多
Magnetic field gradient tensor technique provides abundant data for delicate inversion of subsurface magnetic susceptibility distribution. Large scale magnetic data inversion imaging requires high speed and accuracy f...Magnetic field gradient tensor technique provides abundant data for delicate inversion of subsurface magnetic susceptibility distribution. Large scale magnetic data inversion imaging requires high speed and accuracy for forward modeling. For arbitrarily distributed susceptibility data on an undulated surface, we propose a fast 3D forward modeling method in the wavenumber domain based on(1) the wavenumber-domain expression of the prism combination model and the Gauss–FFT algorithm and(2) cubic spline interpolation. We apply the proposed 3D forward modeling method to synthetic data and use weighting coefficients in the wavenumber domain to improve the modeling for multiple observation surfaces, and also demonstrate the accuracy and efficiency of the proposed method.展开更多
Full tensor magnetic gradient measurements are available nowadays. These are essential for determining magnetization parameters in deep layers. Using full or partial tensor magnetic gradient measurements to determine ...Full tensor magnetic gradient measurements are available nowadays. These are essential for determining magnetization parameters in deep layers. Using full or partial tensor magnetic gradient measurements to determine the subsurface properties, e.g., magnetic susceptibility, is an inverse problem. Inversion using total magnetic intensity data is a traditional way.Because of di culty in obtaining the practical full tensor magnetic gradient data, the corresponding inversion results are not so widely reported. With the development of superconducting quantum interference devices(SQUIDs), we can acquire the full tensor magnetic gradient data through field measurements. In this paper, we study the inverse problem of retrieving magnetic susceptibility with the field data using our designed low-temperature SQUIDs. The solving methodology based on sparse regularization and an alternating directions method of multipliers is established. Numerical and field data experiments are performed to show the feasibility of our algorithm.展开更多
On the basis of the results of improved analytical expression of computation of gravity anomalies due to a homogeneous polyhedral body composed of polygonal facets, and applying the forward theory with the coordinate ...On the basis of the results of improved analytical expression of computation of gravity anomalies due to a homogeneous polyhedral body composed of polygonal facets, and applying the forward theory with the coordinate transformation of vectors and tensors, we deduced both the analytical expressions for gravity gradient tensors and for magnetic anomalies of a polygon, and obtained new analytical expressions for computing vertical gradients of gravity anomalies and vertical component of magnetic anomalies caused by a polyhedral body. And also we developed explicitly the complete unified expressions for the calculation of gravity anomalies, gravity gradient, and magnetic anomalies due to the homogeneous polyhedron. Furthermore, we deduced new analytical expressions for computing vertical gradients of gravity anomalies due to a finite rectangular prism by applying the newly obtained expressions for gravity gradient tensors due to a polyhedral target body. Comparison with forward calculation of models shows the correctness of these new expressions. It will reduce forward calculation time of gravity-magnetic anomalies and improve computational efficiency by applying our unified expressions for joint forward modeling of gravity-magnetic anomalies due to homogeneous polyhedral bodies.展开更多
We consider a cantilever mechanical oscillator(MO) made of diamond. A nitrogen-vacancy(NV) center lies at the end of the cantilever. Two magnetic tips near the NV center induce a strong second-order magnetic field gra...We consider a cantilever mechanical oscillator(MO) made of diamond. A nitrogen-vacancy(NV) center lies at the end of the cantilever. Two magnetic tips near the NV center induce a strong second-order magnetic field gradient. Under coherent driving of the MO, we find that the coupling between the MO and the NV center is greatly enhanced. We studied how to generate entanglement between the MO and the NV center and realize quantum state transfer between them. We also propose a scheme to generate two-mode squeezing between different MO modes by coupling them to the same NV center. The decoherence and dissipation effects for both the MO and the NV center are numerically calculated using the present parameter values of the experimental configuration. We have achieved high fidelity for entanglement generation, quantum state transfer, and large twomode squeezing.展开更多
The technology of locating magnetic anomaly targets via geomagnetic eld measurements has been increasingly widely applied,with multiple magnetic anomaly target localization emerging as a critical research direction.Ho...The technology of locating magnetic anomaly targets via geomagnetic eld measurements has been increasingly widely applied,with multiple magnetic anomaly target localization emerging as a critical research direction.However,when two magnetic anomaly targets are horizontally close but vertically separated,traditional clustering-based localization methods tend to omit the deeper target.To address this issue,we propose an improved clustering-based localization method for multiple magnetic anomaly targets,which integrates two core innovations:the introduction of a reference target to establish a benchmark for normal magnetic moment distribution,and the utilization of spatial distribution characteristics of magnetic moment estimates to judge the presence of omitted targets.Simulation results demonstrate that the proposed method not only achieves accurate localization of conventional targets but also eectively identies the omission of deeper targets,providing a reliable basis for determining whether supplementary localization steps are required.展开更多
In this paper,we investigate the method of compensating LTS SQUID Gradiometer Systems data.By matching the attitude changes of the pod in fl ight to the anomalies of the magnetic measurement data,we find that the yaw ...In this paper,we investigate the method of compensating LTS SQUID Gradiometer Systems data.By matching the attitude changes of the pod in fl ight to the anomalies of the magnetic measurement data,we find that the yaw attitude changes most dramatically and corresponds best to the magnetic data anomaly interval.Based on this finding,we solved the compensation model using least squares fitting and Huber's parametric fitting.By comparison,we found that the Huber parametric fit not only eliminates the interference introduced by attitude changes but also retains richer anomaly source information and therefore obtains a higher signal-to-noise ratio.The experimental results show that the quality of the magnetometry data obtained by using the compensation method proposed in this paper has been significantly improved,and the mean value of its improvement ratio can reach 118.93.展开更多
基金supported by the National High Technology Research and Development Program of China(863 Program)(No.2013AA063901 and No.2006AA06A201)
文摘The full magnetic gradient tensor (MGT) refers to the spatial change rate of the three field components of the geomagnetic field vector along three mutually orthogonal axes. The tensor is of use to geological mapping, resources exploration, magnetic navigation, and others. However, it is very difficult to measure the full magnetic tensor gradient using existing engineering technology. We present a method to use triaxial aeromagnetic gradient measurements for deriving the full MGT. The method uses the triaxial gradient data and makes full use of the variation of the magnetic anomaly modulus in three dimensions to obtain a self-consistent magnetic tensor gradient. Numerical simulations show that the full MGT data obtained with the proposed method are of high precision and satisfy the requirements of data processing. We selected triaxial aeromagnetic gradient data from the Hebei Province for calculating the full MGT. Data processing shows that using triaxial tensor gradient data allows to take advantage of the spatial rate of change of the total field in three dimensions and suppresses part of the independent noise in the aeromagnetic gradient. The calculated tensor components have improved resolution, and the transformed full tensor gradient satisfies the requirement of geological mapping and interpretation.
基金supported by the National Natural Science Foundation of China(61473023)
文摘Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tensor, field differentiation is generally approximated by field difference. As a result, magnetic objects positioning by magnetic field gradient tensor measurement always involves an inherent error caused by sensor sizes, leading to a reduction in detectable distance and detectable angle. In this paper, the inherent positioning error caused by magnetic field gradient tensor measurement is calculated and corrected by iterations based on the systematic position error distribution patterns. The results show that, the detectable distance range and the angle range of an ac magnetic object(2.44 Am^2@1 kHz) can be increased from(0.45 m, 0.75 m),(0?, 25?) to(0.30 m, 0.80 m),(0?,80?), respectively.
基金supported by the National Key R&D Program of China (No. 2017YFC0602204)。
文摘Compared to conventional magnetic data,magnetic gradient tensor data contain more high-frequency signal components,which can better describe the features of geological bodies.The directional analytic signal of the magnetic gradient tensor is not easily interfered from the tilting magnetization,but it can infer the range of the fi eld source more accurately.However,the analytic signal strength decays faster with depth,making it diffi cult to identify deep fi eld sources.Balanced-boundary recognition can eff ectively overcome this disadvantage.We present here a balanced-boundary identifi cation technique based on the normalization of three-directional analytic signals from aeromagnetic gradient tensor data.This method can eff ectively prevent the fast attenuation of analytic signals.We also derive an Euler inversion algorithm of three-directional analytic signal derivative.By combining magnetic-anomaly model testing with the traditional magnetic anomaly interpretation method,we show that the boundary-recognition technology based on a magnetic gradient tensor analytic signal has a greater advantage in identifying the boundaries of the geological body and can better refl ect shallow anomalies.The characteristics of the Euler equation based on the magnetic anomaly direction to resolve the signal derivative have better convergence,and the obtained solution is more concentrated,which can obtain the depth and horizontal range information of the geological body more accurately.Applying the above method to the measured magneticanomaly gradient data from Baoding area,more accurate fi eld source information is obtained,which shows the feasibility of applying this method to geological interpretations.
基金supported by the National Special Plan for the 13th Five-Year Plan of China(No.2017YFC0602204-10)Independent Exploration of the Innovation Project for Graduate Students at Central South University(No.2017zzts176)+3 种基金National Natural Science Foundation of China(Nos.41574127,41404106,and 41674075)Postdoctoral Fund Projects of China(No.2017M622608)National Key R&D Program of China(No.2018YFC0603602)Natural Science Youth Fund Project of the Hunan Province,China(No.2018JJ3642)
文摘Magnetic field gradient tensor technique provides abundant data for delicate inversion of subsurface magnetic susceptibility distribution. Large scale magnetic data inversion imaging requires high speed and accuracy for forward modeling. For arbitrarily distributed susceptibility data on an undulated surface, we propose a fast 3D forward modeling method in the wavenumber domain based on(1) the wavenumber-domain expression of the prism combination model and the Gauss–FFT algorithm and(2) cubic spline interpolation. We apply the proposed 3D forward modeling method to synthetic data and use weighting coefficients in the wavenumber domain to improve the modeling for multiple observation surfaces, and also demonstrate the accuracy and efficiency of the proposed method.
基金supported by National Natural Science Foundation of China(Grant Nos.91630202,41611530693&1181101259)R&D of Key Instruments and Technologies for Deep Resources Prospecting(Grant No.ZDYZ2012-1-02-04)+1 种基金National Key R&D Program(Grant No.2018YFC0603500)Russian Foundation for Basic Research(Grant No.17-51-53002)
文摘Full tensor magnetic gradient measurements are available nowadays. These are essential for determining magnetization parameters in deep layers. Using full or partial tensor magnetic gradient measurements to determine the subsurface properties, e.g., magnetic susceptibility, is an inverse problem. Inversion using total magnetic intensity data is a traditional way.Because of di culty in obtaining the practical full tensor magnetic gradient data, the corresponding inversion results are not so widely reported. With the development of superconducting quantum interference devices(SQUIDs), we can acquire the full tensor magnetic gradient data through field measurements. In this paper, we study the inverse problem of retrieving magnetic susceptibility with the field data using our designed low-temperature SQUIDs. The solving methodology based on sparse regularization and an alternating directions method of multipliers is established. Numerical and field data experiments are performed to show the feasibility of our algorithm.
基金This paper is supported by the National Natural Science Foundation of China (No.40374039)Program for New Century Excellent Talents in University (No. NCET-04-0726)the Focused Subject Program of Beijing (No. XK104910598).
文摘On the basis of the results of improved analytical expression of computation of gravity anomalies due to a homogeneous polyhedral body composed of polygonal facets, and applying the forward theory with the coordinate transformation of vectors and tensors, we deduced both the analytical expressions for gravity gradient tensors and for magnetic anomalies of a polygon, and obtained new analytical expressions for computing vertical gradients of gravity anomalies and vertical component of magnetic anomalies caused by a polyhedral body. And also we developed explicitly the complete unified expressions for the calculation of gravity anomalies, gravity gradient, and magnetic anomalies due to the homogeneous polyhedron. Furthermore, we deduced new analytical expressions for computing vertical gradients of gravity anomalies due to a finite rectangular prism by applying the newly obtained expressions for gravity gradient tensors due to a polyhedral target body. Comparison with forward calculation of models shows the correctness of these new expressions. It will reduce forward calculation time of gravity-magnetic anomalies and improve computational efficiency by applying our unified expressions for joint forward modeling of gravity-magnetic anomalies due to homogeneous polyhedral bodies.
基金supported by the National Natural Science Foundation of China(Grant Nos.61435007,11175094,91221205)the National Basic Research Program of China(Grant No.2015CB921002)
文摘We consider a cantilever mechanical oscillator(MO) made of diamond. A nitrogen-vacancy(NV) center lies at the end of the cantilever. Two magnetic tips near the NV center induce a strong second-order magnetic field gradient. Under coherent driving of the MO, we find that the coupling between the MO and the NV center is greatly enhanced. We studied how to generate entanglement between the MO and the NV center and realize quantum state transfer between them. We also propose a scheme to generate two-mode squeezing between different MO modes by coupling them to the same NV center. The decoherence and dissipation effects for both the MO and the NV center are numerically calculated using the present parameter values of the experimental configuration. We have achieved high fidelity for entanglement generation, quantum state transfer, and large twomode squeezing.
基金funded by the Youth Project of Basic Research Plan for Natural Sciences in Shaanxi Province,grant number 2024JC-YBQN-0253.
文摘The technology of locating magnetic anomaly targets via geomagnetic eld measurements has been increasingly widely applied,with multiple magnetic anomaly target localization emerging as a critical research direction.However,when two magnetic anomaly targets are horizontally close but vertically separated,traditional clustering-based localization methods tend to omit the deeper target.To address this issue,we propose an improved clustering-based localization method for multiple magnetic anomaly targets,which integrates two core innovations:the introduction of a reference target to establish a benchmark for normal magnetic moment distribution,and the utilization of spatial distribution characteristics of magnetic moment estimates to judge the presence of omitted targets.Simulation results demonstrate that the proposed method not only achieves accurate localization of conventional targets but also eectively identies the omission of deeper targets,providing a reliable basis for determining whether supplementary localization steps are required.
基金Earth Observation and Navigation Special,Research on Low Temperature Superconducting Aeromagnetic Vector Gradient Observation Technology(2021YFB3900201)projectState Key Laboratory of Remote Sensing Science project.
文摘In this paper,we investigate the method of compensating LTS SQUID Gradiometer Systems data.By matching the attitude changes of the pod in fl ight to the anomalies of the magnetic measurement data,we find that the yaw attitude changes most dramatically and corresponds best to the magnetic data anomaly interval.Based on this finding,we solved the compensation model using least squares fitting and Huber's parametric fitting.By comparison,we found that the Huber parametric fit not only eliminates the interference introduced by attitude changes but also retains richer anomaly source information and therefore obtains a higher signal-to-noise ratio.The experimental results show that the quality of the magnetometry data obtained by using the compensation method proposed in this paper has been significantly improved,and the mean value of its improvement ratio can reach 118.93.