To address the installation challenges of a 2-m ring Gregorian telescope system,and similar optical systems with a small width-to-radius ratio,we propose a detection method combining local interferometry with a compar...To address the installation challenges of a 2-m ring Gregorian telescope system,and similar optical systems with a small width-to-radius ratio,we propose a detection method combining local interferometry with a comparison model.This method enhances the precision of system calibration by establishing a dataset that delineates the relationship between secondary mirror misalignment and wavefront aberration,subsequently inferring the misalignment from interferometric detection results during the calibration process.For the 2-m ring telescope,we develop a detection model using five local sub-apertures,enabling a root-mean-square detection accuracy of 0:0225λ(λ=632:8 nm)for full-aperture wavefront aberration.The calibration results for the 2-m Ring Solar Telescope system indicate that the root-mean-square value of sub-aperture wavefront aberration reaches 0.104λ,and the root-mean-square value of spliced full-aperture measurement yields reaches 0.112λ.This method offers a novel approach for calibrating small width-toradius ratio telescope systems and can be applied to the calibration of other irregular-aperture optical systems.展开更多
Accurate kinematic calibration is the very foundation for robots'application in industry demanding high precision such as machining.Considering the complex error characteristic and severe ill-posed identification ...Accurate kinematic calibration is the very foundation for robots'application in industry demanding high precision such as machining.Considering the complex error characteristic and severe ill-posed identification issues of a 5-DoF parallel machining robot,this paper proposes an adaptive and weighted identification method to achieve high-precision kinematic calibration while maintaining reliable stability.First,a kinematic error propagation mechanism model considering the non-ideal constraints and the screw self-rotation is formulated by incorporating the intricate structure of multiple chains and a unique driven screw arrangement of the robot.To address the challenge of accurately identifying such a sophisticated error model,a novel adaptive and weighted identification method based on generalized cross validation(GCV)is proposed.Specifically,this approach innovatively introduces Gauss-Markov estimation into the GCV algorithm and utilizes prior physical information to construct both a weighted identification model and a weighted cross-validation function,thus eliminating the inaccuracy caused by significant differences in dimensional magnitudes of pose errors and achieving accurate identification with flexible numerical stability.Finally,the kinematic calibration experiment is conducted.The comparative experimental results demonstrate that the presented approach is effective and has enhanced accuracy performance over typical least squares methods,with maximum position and orientation errors reduced from 2.279 mm to 0.028 mm and from 0.206°to 0.017°,respectively.展开更多
A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD ...A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD (alternating penalty trilinear decomposition) algorithm was proposed to analyze the three-way HPLC-DAD data from both standard and prediction samples, which makes it possible that calibration can be performed even in the presence of unknown interferences with a simple and green chromatographic condition and short analysis time. The results showed that good recoveries were obtained although the chromatographic and spectral profiles of the analytes of interest as well as background were partially overlapped with each other in plasma samples.展开更多
The effectiveness of traditional Chinese medicine (TCM) against various diseases urges more low cost, speed and sensitive analytical methods for investigating the phamacology of TCM and providing a theoretical basis f...The effectiveness of traditional Chinese medicine (TCM) against various diseases urges more low cost, speed and sensitive analytical methods for investigating the phamacology of TCM and providing a theoretical basis for clinical use. The potential of second-order calibration method was validated for the quantification of two effective ingredients of Schisandra chinensis in human plasma using spectrofluorimetry. The results obtained in the present study demonstrate the advantages of this strategy for multi-target determination in complex matrices. Although the spectra of the analytes are similar and a large number of interferences also exist, second-order calibration method could predict the accurate concentrations together with reasonable resolution of spectral profiles for analytes of interest owing to its ‘second-order advantage’. Moreover, the method presented in this work allows one to simply experimental procedure as well as reduces the use of harmful chemical solvents.展开更多
An HPLC-DAD method combined with second-order calibration based on the alternating trilinear decomposition(ATLD)algorithm with the aid of region selection was developed to simultaneously and quantitatively characteriz...An HPLC-DAD method combined with second-order calibration based on the alternating trilinear decomposition(ATLD)algorithm with the aid of region selection was developed to simultaneously and quantitatively characterize the synergistic relationships and cumulative excretion of the four bioactive ingredients of Radix Gentianae Macrophyllae in vivo.Although the analytes spectra substantially overlapped with that of the biological matrix,the overlapping profiles between analytes and co-eluting interferences can be successfully separated and accurately quantified by the ATLD method on the basis of the strength of region selection.The proposed approach not only determined the content change but also revealed the synergistic relationships and the cumulative excretion in vivo of the four ingredients in urine and feces samples collected at different excretion time intervals.In addition,several statistical parameters were employed to evaluate the accuracy and precision of the method.Quantitative results were confirmed by HPLC-mass spectrometry.Satisfactory results indicated that the proposed approach can be utilized to investigate the pharmacokinetics of Radix Gentianae Macrophyllae excretion in vivo.展开更多
With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study...With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks.展开更多
A globally convergent infeasible-interior-point predictor-corrector algorithm is presented for the second-order cone programming (SOCP) by using the Alizadeh- Haeberly-Overton (AHO) search direction. This algorith...A globally convergent infeasible-interior-point predictor-corrector algorithm is presented for the second-order cone programming (SOCP) by using the Alizadeh- Haeberly-Overton (AHO) search direction. This algorithm does not require the feasibility of the initial points and iteration points. Under suitable assumptions, it is shown that the algorithm can find an -approximate solution of an SOCP in at most O(√n ln(ε0/ε)) iterations. The iteration-complexity bound of our algorithm is almost the same as the best known bound of feasible interior point algorithms for the SOCP.展开更多
The kinematic error model of a 6-DOF space robot is deduced, and the cost function of kinematic parameter identification is built. With the aid of the genetic algorithm (GA) that has the powerful global adaptive pro...The kinematic error model of a 6-DOF space robot is deduced, and the cost function of kinematic parameter identification is built. With the aid of the genetic algorithm (GA) that has the powerful global adaptive probabilistic search ability, 24 parameters of the robot are identified through simulation, which makes the pose (position and orientation) accuracy of the robot a great improvement. In the process of the calibration, stochastic measurement noises are considered. Lastly, generalization of the identified kinematic parameters in the whole workspace of the robot is discussed. The simulation results show that calibrating the robot with GA is very stable and not sensitive to measurement noise. Moreover, even if the robot's kinematic parameters are relative, GA still has strong search ability to find the optimum solution.展开更多
In this paper, we propose a compound algorithm for the image restoration. The algorithm is a convex combination of the ROF model and the LLT model with a parameter function 0. The numerical experiments demonstrate tha...In this paper, we propose a compound algorithm for the image restoration. The algorithm is a convex combination of the ROF model and the LLT model with a parameter function 0. The numerical experiments demonstrate that our compound algorithm is efficient and preserves the main advantages of the two models. In particular, the errors of the compound algorithm in L2 norm between the exact images and corresponding restored images are the smallest among the three models. For images with strong noises, the restored images of the compound algorithm are the best in the corresponding restored images. The proposed algorithm combines the fixed point method, an improved AMG method and the Krylov acceleration. It is found that the combination of these methods is efficient and robust in the image restoration.展开更多
Accurate stereo vision calibration is a preliminary step towards high-precision visual posi- tioning of robot. Combining with the characteristics of genetic algorithm (GA) and particle swarm optimization (PSO), a ...Accurate stereo vision calibration is a preliminary step towards high-precision visual posi- tioning of robot. Combining with the characteristics of genetic algorithm (GA) and particle swarm optimization (PSO), a three-stage calibration method based on hybrid intelligent optimization is pro- posed for nonlinear camera models in this paper. The motivation is to improve the accuracy of the calibration process. In this approach, the stereo vision calibration is considered as an optimization problem that can be solved by the GA and PSO. The initial linear values can be obtained in the frost stage. Then in the second stage, two cameras' parameters are optimized separately. Finally, the in- tegrated optimized calibration of two models is obtained in the third stage. Direct linear transforma- tion (DLT), GA and PSO are individually used in three stages. It is shown that the results of every stage can correctly find near-optimal solution and it can be used to initialize the next stage. Simula- tion analysis and actual experimental results indicate that this calibration method works more accu- rate and robust in noisy environment compared with traditional calibration methods. The proposed method can fulfill the requirements of robot sophisticated visual operation.展开更多
Based on the ideas of infeasible interior-point methods and predictor-corrector algorithms, two interior-point predictor-corrector algorithms for the second-order cone programming (SOCP) are presented. The two algor...Based on the ideas of infeasible interior-point methods and predictor-corrector algorithms, two interior-point predictor-corrector algorithms for the second-order cone programming (SOCP) are presented. The two algorithms use the Newton direction and the Euler direction as the predictor directions, respectively. The corrector directions belong to the category of the Alizadeh-Haeberly-Overton (AHO) directions. These algorithms are suitable to the cases of feasible and infeasible interior iterative points. A simpler neighborhood of the central path for the SOCP is proposed, which is the pivotal difference from other interior-point predictor-corrector algorithms. Under some assumptions, the algorithms possess the global, linear, and quadratic convergence. The complexity bound O(rln(εo/ε)) is obtained, where r denotes the number of the second-order cones in the SOCP problem. The numerical results show that the proposed algorithms are effective.展开更多
This paper deals with the scanner exterior calibration algorithm when the scanner is arranged by the robot and the object scanned is fixed on a rotate device in the Robot Remanufacturing System. The method of calibrat...This paper deals with the scanner exterior calibration algorithm when the scanner is arranged by the robot and the object scanned is fixed on a rotate device in the Robot Remanufacturing System. The method of calibrating the relationship between the scanner coordinate and the robot Tool0, such as the rotation, Rx, Ry, Rz, and the transformation ,Y, Z is studied. The data of Tool0 can be directly obtained from the relationship with the robot base-coordinate. So, the coordinate relationship between the scanner coordinate and the robot base coordinate can be easily gotten. This paper explains the basic algorithm theory, computing method, data collecting process and the resulted data in detail. The calibration algorithm is deduced under the orthogonal coordinate.展开更多
This paper presents a method to calibrate pipe roughness coefficient (i.e., Manning n-factor) with genetic algorithm (GA) under multiple loading conditions. Due to the old pipe age as well as deleting valves and blend...This paper presents a method to calibrate pipe roughness coefficient (i.e., Manning n-factor) with genetic algorithm (GA) under multiple loading conditions. Due to the old pipe age as well as deleting valves and blends in the skeleton of distribution network, most of the pipes in hydraulic model of practical water distribution system (WDS) are rough. The commonly used Hazen-Williams C-factor is therefore replaced by Manning n-factor in calibrating WDS hydraulic model. Adjustment to GA is designed, and the program efficiency is improved. A case study shows that the adjustment can save 60% of the total runtime. About 90% of the relative differences between simulated and observed pressures at monitoring locations are lower than 3%, which suggests that the proposed adjustment to the calibration is efficient and effective.展开更多
An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the ...An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the positionbased visual servo technique which exploits the singular value property of the essential matrix. Specifically, a suitable dynamic online cost function is generated according to the property of the three singular values. The visual servo process is carried out simultaneous to the dynamic self-calibration, and then the cost function is minimized using the adaptive genetic algorithm instead of the gradient descent method in G. Chesi's approach. Moreover, this method overcomes the limitation that the initial parameters must be selected close to the true value, which is not constant in many cases. It is not necessary to know exactly the camera intrinsic parameters when using our approach, instead, coarse coding bounds of the five parameters are enough for the algorithm, which can be done once and for all off-line. Besides, this algorithm does not require knowledge of the 3D model of the object. Simulation experiments are carried out and the results demonstrate that the proposed approach provides a fast convergence speed and robustness against unpredictable perturbations of camera parameters, and it is an effective and efficient visual servo algorithm.展开更多
In this paper,a new adaptive calibration algorithm for image steganalysis is proposed.Steganography disturbs the dependence between neighboring pixels and decreases the neighborhood node degree.Firstly,we analyzed the...In this paper,a new adaptive calibration algorithm for image steganalysis is proposed.Steganography disturbs the dependence between neighboring pixels and decreases the neighborhood node degree.Firstly,we analyzed the effect of steganography on the neighborhood node degree of cover images.Then,the calibratable pixels are marked by the analysis of neighborhood node degree.Finally,the strong correlation calibration image is constructed by revising the calibratable pixels.Experimental results reveal that compared with secondary steganography the image calibration method significantly increased the detection accuracy for LSB matching steganography on low embedding ratio.The proposed method also has a better performance against spatial steganography.展开更多
This paper demonstrates that the application of calibration algorithms of aerodynamic parameters for the trajectory of spinning projectile is successful. First, from the point of view of the trajectory simulation, a g...This paper demonstrates that the application of calibration algorithms of aerodynamic parameters for the trajectory of spinning projectile is successful. First, from the point of view of the trajectory simulation, a general summary of well-known trajectory models is given. A five degrees of freedom (5 DOF) model is developed that can match the projectile motion essentially in the vertex region, and the results obtained by 5 DOF model are in close agreement with those of a more sophisticated 6 DOF model for elevation angles above 45 degrees. Secondly, the calibration algorithms have been developed and are summarized. The methods of calibrating the flight trajectory models are compared, and these methods are shown to be effective in the representative cases. In addition, the method of Math number calibration (MNC) is presented; some possible areas in MNC for further investigation are indicated together with benefits to be gained. The utilization of MNC schemes not only allow a worthwhile reduction of calibration rounds firing in range and accuracy (R&A) trial and production of firing tables (PFT) test, but also make PFT and fire control data (FCD) more cost effective.展开更多
In this paper, a novel algorithm is presented for direction of arrival(DOA) estimation and array self-calibration in the presence of unknown mutual coupling. In order to highlight the relationship between the array ...In this paper, a novel algorithm is presented for direction of arrival(DOA) estimation and array self-calibration in the presence of unknown mutual coupling. In order to highlight the relationship between the array output and mutual coupling coefficients, we present a novel model of the array output with the unknown mutual coupling coefficients. Based on this model, we use the space alternating generalized expectation-maximization(SAGE) algorithm to jointly estimate the DOA parameters and the mutual coupling coefficients. Unlike many existing counterparts, our method requires neither calibration sources nor initial calibration information. At the same time,our proposed method inherits the characteristics of good convergence and high estimation precision of the SAGE algorithm. By numerical experiments we demonstrate that our proposed method outperforms the existing method for DOA estimation and mutual coupling calibration.展开更多
In order to reduce the fluctuation of LIBS detection spectrum of liquid sample,the full-spectrum sum method and the internal standardization method is adopted,using an equal-RSD normalization algorithm to calibrate th...In order to reduce the fluctuation of LIBS detection spectrum of liquid sample,the full-spectrum sum method and the internal standardization method is adopted,using an equal-RSD normalization algorithm to calibrate the detection spectrum.Experiment result shows that the full-spectrum sum method reduced the RSD of parallel samples of Cd and Cr to 9.4% and 11.06% from 28.32% and 31.93% respectively,yielded better overall calibration than the singleelement internal standardization approach,thereby suggesting that the former method is convenient and effective for online calibration of LIBS for detection of aqueous heavy metals.展开更多
In this paper,we study the electromagnetic scattering from a two dimen- sional large rectangular open cavity embedded in an infinite ground plane,which is modelled by Helmholtz equations.By introducing nonlocal transp...In this paper,we study the electromagnetic scattering from a two dimen- sional large rectangular open cavity embedded in an infinite ground plane,which is modelled by Helmholtz equations.By introducing nonlocal transparent boundary con- ditions,the problem in the open cavity is reduced to a bounded domain problem.A hypersingular integral operator and a weakly singular integral operator are involved in the TM and TE cases,respectively.A new second-order Toeplitz type approximation and a second-order finite difference scheme are proposed for approximating the hyper- singular integral operator on the aperture and the Helmholtz in the cavity,respectively. The existence and uniqueness of the numerical solution in the TE case are established for arbitrary wavenumbers.A fast algorithm for the second-order approximation is pro- posed for solving the cavity model with layered media.Numerical results show the second-order accuracy and efficiency of the fast algorithm.More important is that the algorithm is easy to implement as a preconditioner for cavity models with more general media.展开更多
基金supported by the Jiangsu Provincial Key Research and Development Program(BE2022072)the National Natural Science Foundation of China(12141304)the Natural Science Foundation of Jiangsu Province(BK20231134).
文摘To address the installation challenges of a 2-m ring Gregorian telescope system,and similar optical systems with a small width-to-radius ratio,we propose a detection method combining local interferometry with a comparison model.This method enhances the precision of system calibration by establishing a dataset that delineates the relationship between secondary mirror misalignment and wavefront aberration,subsequently inferring the misalignment from interferometric detection results during the calibration process.For the 2-m ring telescope,we develop a detection model using five local sub-apertures,enabling a root-mean-square detection accuracy of 0:0225λ(λ=632:8 nm)for full-aperture wavefront aberration.The calibration results for the 2-m Ring Solar Telescope system indicate that the root-mean-square value of sub-aperture wavefront aberration reaches 0.104λ,and the root-mean-square value of spliced full-aperture measurement yields reaches 0.112λ.This method offers a novel approach for calibrating small width-toradius ratio telescope systems and can be applied to the calibration of other irregular-aperture optical systems.
基金Supported by National Key R&D Program of China(Grant No.2022YFB3404101)National Natural Science Foundation of China(Grant Nos.52375018,92148301)。
文摘Accurate kinematic calibration is the very foundation for robots'application in industry demanding high precision such as machining.Considering the complex error characteristic and severe ill-posed identification issues of a 5-DoF parallel machining robot,this paper proposes an adaptive and weighted identification method to achieve high-precision kinematic calibration while maintaining reliable stability.First,a kinematic error propagation mechanism model considering the non-ideal constraints and the screw self-rotation is formulated by incorporating the intricate structure of multiple chains and a unique driven screw arrangement of the robot.To address the challenge of accurately identifying such a sophisticated error model,a novel adaptive and weighted identification method based on generalized cross validation(GCV)is proposed.Specifically,this approach innovatively introduces Gauss-Markov estimation into the GCV algorithm and utilizes prior physical information to construct both a weighted identification model and a weighted cross-validation function,thus eliminating the inaccuracy caused by significant differences in dimensional magnitudes of pose errors and achieving accurate identification with flexible numerical stability.Finally,the kinematic calibration experiment is conducted.The comparative experimental results demonstrate that the presented approach is effective and has enhanced accuracy performance over typical least squares methods,with maximum position and orientation errors reduced from 2.279 mm to 0.028 mm and from 0.206°to 0.017°,respectively.
基金financially supported by The National Natural Science Foundation of China(No.20775025)The National Basic Research Program(No.2007CB216404) as well as PCSIRT
文摘A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD (alternating penalty trilinear decomposition) algorithm was proposed to analyze the three-way HPLC-DAD data from both standard and prediction samples, which makes it possible that calibration can be performed even in the presence of unknown interferences with a simple and green chromatographic condition and short analysis time. The results showed that good recoveries were obtained although the chromatographic and spectral profiles of the analytes of interest as well as background were partially overlapped with each other in plasma samples.
基金the National Natural Science Foundation of China (Grant No. 21175041)the National Basic Research Program (Grant No. 2012CB910602)Program for Changjiang Scholars and Innovative Research Team in University (PCSIRT) for financial supports
文摘The effectiveness of traditional Chinese medicine (TCM) against various diseases urges more low cost, speed and sensitive analytical methods for investigating the phamacology of TCM and providing a theoretical basis for clinical use. The potential of second-order calibration method was validated for the quantification of two effective ingredients of Schisandra chinensis in human plasma using spectrofluorimetry. The results obtained in the present study demonstrate the advantages of this strategy for multi-target determination in complex matrices. Although the spectra of the analytes are similar and a large number of interferences also exist, second-order calibration method could predict the accurate concentrations together with reasonable resolution of spectral profiles for analytes of interest owing to its ‘second-order advantage’. Moreover, the method presented in this work allows one to simply experimental procedure as well as reduces the use of harmful chemical solvents.
基金support from the National Natural Science Foundation of China(Grants Nos.21776321,21576297,21205145,21575039)Key Projects of Technological Innovation of Hubei Province(2016ACA138)The Open Research Program(Grant Nos.2015ZD001,2015ZD002 and 2015ZY006)。
文摘An HPLC-DAD method combined with second-order calibration based on the alternating trilinear decomposition(ATLD)algorithm with the aid of region selection was developed to simultaneously and quantitatively characterize the synergistic relationships and cumulative excretion of the four bioactive ingredients of Radix Gentianae Macrophyllae in vivo.Although the analytes spectra substantially overlapped with that of the biological matrix,the overlapping profiles between analytes and co-eluting interferences can be successfully separated and accurately quantified by the ATLD method on the basis of the strength of region selection.The proposed approach not only determined the content change but also revealed the synergistic relationships and the cumulative excretion in vivo of the four ingredients in urine and feces samples collected at different excretion time intervals.In addition,several statistical parameters were employed to evaluate the accuracy and precision of the method.Quantitative results were confirmed by HPLC-mass spectrometry.Satisfactory results indicated that the proposed approach can be utilized to investigate the pharmacokinetics of Radix Gentianae Macrophyllae excretion in vivo.
基金supported by the National Natural Science Foundation of China(Nos.41374130 and 41604154)
文摘With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks.
基金the National Science Foundation(60574075, 60674108)
文摘A globally convergent infeasible-interior-point predictor-corrector algorithm is presented for the second-order cone programming (SOCP) by using the Alizadeh- Haeberly-Overton (AHO) search direction. This algorithm does not require the feasibility of the initial points and iteration points. Under suitable assumptions, it is shown that the algorithm can find an -approximate solution of an SOCP in at most O(√n ln(ε0/ε)) iterations. The iteration-complexity bound of our algorithm is almost the same as the best known bound of feasible interior point algorithms for the SOCP.
基金supported by National Natural Science Foundation of China(No.60775049).
文摘The kinematic error model of a 6-DOF space robot is deduced, and the cost function of kinematic parameter identification is built. With the aid of the genetic algorithm (GA) that has the powerful global adaptive probabilistic search ability, 24 parameters of the robot are identified through simulation, which makes the pose (position and orientation) accuracy of the robot a great improvement. In the process of the calibration, stochastic measurement noises are considered. Lastly, generalization of the identified kinematic parameters in the whole workspace of the robot is discussed. The simulation results show that calibrating the robot with GA is very stable and not sensitive to measurement noise. Moreover, even if the robot's kinematic parameters are relative, GA still has strong search ability to find the optimum solution.
基金suppprt from NSFC of China,Singapore NTU project SUG 20/07,MOE Grant T207B2202NRF2007IDMIDM002-010
文摘In this paper, we propose a compound algorithm for the image restoration. The algorithm is a convex combination of the ROF model and the LLT model with a parameter function 0. The numerical experiments demonstrate that our compound algorithm is efficient and preserves the main advantages of the two models. In particular, the errors of the compound algorithm in L2 norm between the exact images and corresponding restored images are the smallest among the three models. For images with strong noises, the restored images of the compound algorithm are the best in the corresponding restored images. The proposed algorithm combines the fixed point method, an improved AMG method and the Krylov acceleration. It is found that the combination of these methods is efficient and robust in the image restoration.
文摘Accurate stereo vision calibration is a preliminary step towards high-precision visual posi- tioning of robot. Combining with the characteristics of genetic algorithm (GA) and particle swarm optimization (PSO), a three-stage calibration method based on hybrid intelligent optimization is pro- posed for nonlinear camera models in this paper. The motivation is to improve the accuracy of the calibration process. In this approach, the stereo vision calibration is considered as an optimization problem that can be solved by the GA and PSO. The initial linear values can be obtained in the frost stage. Then in the second stage, two cameras' parameters are optimized separately. Finally, the in- tegrated optimized calibration of two models is obtained in the third stage. Direct linear transforma- tion (DLT), GA and PSO are individually used in three stages. It is shown that the results of every stage can correctly find near-optimal solution and it can be used to initialize the next stage. Simula- tion analysis and actual experimental results indicate that this calibration method works more accu- rate and robust in noisy environment compared with traditional calibration methods. The proposed method can fulfill the requirements of robot sophisticated visual operation.
基金supported by the National Natural Science Foundation of China (Nos. 71061002 and 11071158)the Natural Science Foundation of Guangxi Province of China (Nos. 0832052 and 2010GXNSFB013047)
文摘Based on the ideas of infeasible interior-point methods and predictor-corrector algorithms, two interior-point predictor-corrector algorithms for the second-order cone programming (SOCP) are presented. The two algorithms use the Newton direction and the Euler direction as the predictor directions, respectively. The corrector directions belong to the category of the Alizadeh-Haeberly-Overton (AHO) directions. These algorithms are suitable to the cases of feasible and infeasible interior iterative points. A simpler neighborhood of the central path for the SOCP is proposed, which is the pivotal difference from other interior-point predictor-corrector algorithms. Under some assumptions, the algorithms possess the global, linear, and quadratic convergence. The complexity bound O(rln(εo/ε)) is obtained, where r denotes the number of the second-order cones in the SOCP problem. The numerical results show that the proposed algorithms are effective.
文摘This paper deals with the scanner exterior calibration algorithm when the scanner is arranged by the robot and the object scanned is fixed on a rotate device in the Robot Remanufacturing System. The method of calibrating the relationship between the scanner coordinate and the robot Tool0, such as the rotation, Rx, Ry, Rz, and the transformation ,Y, Z is studied. The data of Tool0 can be directly obtained from the relationship with the robot base-coordinate. So, the coordinate relationship between the scanner coordinate and the robot base coordinate can be easily gotten. This paper explains the basic algorithm theory, computing method, data collecting process and the resulted data in detail. The calibration algorithm is deduced under the orthogonal coordinate.
基金Supported by National Natural Science Foundation of China (No 50778121)Science and Technology Innovation Special Foundation of Tianjin (NO 06FZZDSH00900)
文摘This paper presents a method to calibrate pipe roughness coefficient (i.e., Manning n-factor) with genetic algorithm (GA) under multiple loading conditions. Due to the old pipe age as well as deleting valves and blends in the skeleton of distribution network, most of the pipes in hydraulic model of practical water distribution system (WDS) are rough. The commonly used Hazen-Williams C-factor is therefore replaced by Manning n-factor in calibrating WDS hydraulic model. Adjustment to GA is designed, and the program efficiency is improved. A case study shows that the adjustment can save 60% of the total runtime. About 90% of the relative differences between simulated and observed pressures at monitoring locations are lower than 3%, which suggests that the proposed adjustment to the calibration is efficient and effective.
基金the National Natural Science Foundation of China (No.60675048)Science and Technology Research Project of the Ministry of Education (No.204181).
文摘An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the positionbased visual servo technique which exploits the singular value property of the essential matrix. Specifically, a suitable dynamic online cost function is generated according to the property of the three singular values. The visual servo process is carried out simultaneous to the dynamic self-calibration, and then the cost function is minimized using the adaptive genetic algorithm instead of the gradient descent method in G. Chesi's approach. Moreover, this method overcomes the limitation that the initial parameters must be selected close to the true value, which is not constant in many cases. It is not necessary to know exactly the camera intrinsic parameters when using our approach, instead, coarse coding bounds of the five parameters are enough for the algorithm, which can be done once and for all off-line. Besides, this algorithm does not require knowledge of the 3D model of the object. Simulation experiments are carried out and the results demonstrate that the proposed approach provides a fast convergence speed and robustness against unpredictable perturbations of camera parameters, and it is an effective and efficient visual servo algorithm.
基金This work is supported by the National Natural Science Foundation of China(No.61772561)the Key Research&Development Plan of Hunan Province(No.2018NK2012)the Key Laboratory for Digital Dongting Lake Basin of Hunan Province。
文摘In this paper,a new adaptive calibration algorithm for image steganalysis is proposed.Steganography disturbs the dependence between neighboring pixels and decreases the neighborhood node degree.Firstly,we analyzed the effect of steganography on the neighborhood node degree of cover images.Then,the calibratable pixels are marked by the analysis of neighborhood node degree.Finally,the strong correlation calibration image is constructed by revising the calibratable pixels.Experimental results reveal that compared with secondary steganography the image calibration method significantly increased the detection accuracy for LSB matching steganography on low embedding ratio.The proposed method also has a better performance against spatial steganography.
文摘This paper demonstrates that the application of calibration algorithms of aerodynamic parameters for the trajectory of spinning projectile is successful. First, from the point of view of the trajectory simulation, a general summary of well-known trajectory models is given. A five degrees of freedom (5 DOF) model is developed that can match the projectile motion essentially in the vertex region, and the results obtained by 5 DOF model are in close agreement with those of a more sophisticated 6 DOF model for elevation angles above 45 degrees. Secondly, the calibration algorithms have been developed and are summarized. The methods of calibrating the flight trajectory models are compared, and these methods are shown to be effective in the representative cases. In addition, the method of Math number calibration (MNC) is presented; some possible areas in MNC for further investigation are indicated together with benefits to be gained. The utilization of MNC schemes not only allow a worthwhile reduction of calibration rounds firing in range and accuracy (R&A) trial and production of firing tables (PFT) test, but also make PFT and fire control data (FCD) more cost effective.
基金supported by the National Natural Science Foundation of China (No. 61302141)
文摘In this paper, a novel algorithm is presented for direction of arrival(DOA) estimation and array self-calibration in the presence of unknown mutual coupling. In order to highlight the relationship between the array output and mutual coupling coefficients, we present a novel model of the array output with the unknown mutual coupling coefficients. Based on this model, we use the space alternating generalized expectation-maximization(SAGE) algorithm to jointly estimate the DOA parameters and the mutual coupling coefficients. Unlike many existing counterparts, our method requires neither calibration sources nor initial calibration information. At the same time,our proposed method inherits the characteristics of good convergence and high estimation precision of the SAGE algorithm. By numerical experiments we demonstrate that our proposed method outperforms the existing method for DOA estimation and mutual coupling calibration.
文摘In order to reduce the fluctuation of LIBS detection spectrum of liquid sample,the full-spectrum sum method and the internal standardization method is adopted,using an equal-RSD normalization algorithm to calibrate the detection spectrum.Experiment result shows that the full-spectrum sum method reduced the RSD of parallel samples of Cd and Cr to 9.4% and 11.06% from 28.32% and 31.93% respectively,yielded better overall calibration than the singleelement internal standardization approach,thereby suggesting that the former method is convenient and effective for online calibration of LIBS for detection of aqueous heavy metals.
基金supported in part by a grant from the Research Grants Council of the Hong Kong Special Administrative Region,China (Project No.CityU 102204).
文摘In this paper,we study the electromagnetic scattering from a two dimen- sional large rectangular open cavity embedded in an infinite ground plane,which is modelled by Helmholtz equations.By introducing nonlocal transparent boundary con- ditions,the problem in the open cavity is reduced to a bounded domain problem.A hypersingular integral operator and a weakly singular integral operator are involved in the TM and TE cases,respectively.A new second-order Toeplitz type approximation and a second-order finite difference scheme are proposed for approximating the hyper- singular integral operator on the aperture and the Helmholtz in the cavity,respectively. The existence and uniqueness of the numerical solution in the TE case are established for arbitrary wavenumbers.A fast algorithm for the second-order approximation is pro- posed for solving the cavity model with layered media.Numerical results show the second-order accuracy and efficiency of the fast algorithm.More important is that the algorithm is easy to implement as a preconditioner for cavity models with more general media.