A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD ...A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD (alternating penalty trilinear decomposition) algorithm was proposed to analyze the three-way HPLC-DAD data from both standard and prediction samples, which makes it possible that calibration can be performed even in the presence of unknown interferences with a simple and green chromatographic condition and short analysis time. The results showed that good recoveries were obtained although the chromatographic and spectral profiles of the analytes of interest as well as background were partially overlapped with each other in plasma samples.展开更多
The effectiveness of traditional Chinese medicine(TCM)against various diseases urges more low cost,speed and sensitive analytical methods for investigating the phamacology of TCM and providing a theoretical basis for ...The effectiveness of traditional Chinese medicine(TCM)against various diseases urges more low cost,speed and sensitive analytical methods for investigating the phamacology of TCM and providing a theoretical basis for clinical use.The potential of second-order calibration method was validated for the quantification of two effective ingredients of Schisandra chinensis in human plasma using spectrofluorimetry.The results obtained in the present study demonstrate the advantages of this strategy for multi-target determination in complex matrices.Although the spectra of the analytes are similar and a large number of interferences also exist,second-order calibration method could predict the accurate concentrations together with reasonable resolution of spectral profiles for analytes of interest owing to its‘second-order advantage’.Moreover,the method presented in this work allows one to simply experimental procedure as well as reduces the use of harmful chemical solvents.展开更多
A "green" and quick analytical method for complex compounds was developed for simultaneous determination of tyrosine (Tyr) and dopamine (DA) in urine samples in this paper. The three-way responsive data recorded...A "green" and quick analytical method for complex compounds was developed for simultaneous determination of tyrosine (Tyr) and dopamine (DA) in urine samples in this paper. The three-way responsive data recorded by excitation-emission matrix fluorescence (EEM) spectrometer was analyzed using second-order calibration methods based on both parallel factor analysis (PARAFAC) and self- weighted alternating trilinear decomposition (SWATLD) algorithms. The EEM spectra of the analytes were overlapped with the background in urine samples. However the second-order advantage of both PARAFAC and SWATLD methods was exploited, even in the presence of unknown interferences and the satisfactory results can be obtained. Furthermore, the linear ranges of Tyr and DA were determined to be 0.042-6.42 p.g/mL and 0.18-4.43/ug]mL, respectively, and the accuracies of both methods were validated by the analytical figures of merit (FOM).展开更多
An HPLC-DAD method combined with second-order calibration based on the alternating trilinear decomposition(ATLD)algorithm with the aid of region selection was developed to simultaneously and quantitatively characteriz...An HPLC-DAD method combined with second-order calibration based on the alternating trilinear decomposition(ATLD)algorithm with the aid of region selection was developed to simultaneously and quantitatively characterize the synergistic relationships and cumulative excretion of the four bioactive ingredients of Radix Gentianae Macrophyllae in vivo.Although the analytes spectra substantially overlapped with that of the biological matrix,the overlapping profiles between analytes and co-eluting interferences can be successfully separated and accurately quantified by the ATLD method on the basis of the strength of region selection.The proposed approach not only determined the content change but also revealed the synergistic relationships and the cumulative excretion in vivo of the four ingredients in urine and feces samples collected at different excretion time intervals.In addition,several statistical parameters were employed to evaluate the accuracy and precision of the method.Quantitative results were confirmed by HPLC-mass spectrometry.Satisfactory results indicated that the proposed approach can be utilized to investigate the pharmacokinetics of Radix Gentianae Macrophyllae excretion in vivo.展开更多
A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled...A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled with second-order calibration method based on the alternating trilinear decomposition(ATLD) algorithm, the proposed approach can achieve quantitative analysis successfully even in the presence of unknown and uncalibrated interferences. The method shows good linearity for NAP and VB6 with correlation coefficients greater than 0.99. The results were in good agreement with the labeled contents. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring(MRM) based on LC–MS/MS method.T-test demonstrated that there are no significant differences between the prediction results of the two methods. The satisfactory results obtained in this work indicate that the use of the second-order calibration method coupled with the EEM is a promising tool for industrial quality control and pharmaceutical analysis due to its advantages of high sensitivity, low-cost and simple implementation.展开更多
This work presents a novel application of second-order calibration based on self-weighted alternating trilinear decomposition(SWATLD)algorithm for analyzing the HPLC-DAD data.The proposed method makes it possible to s...This work presents a novel application of second-order calibration based on self-weighted alternating trilinear decomposition(SWATLD)algorithm for analyzing the HPLC-DAD data.The proposed method makes it possible to simultaneously determine teflubenzuron,hexaflumuron,flufenoxuron,chlorfluazuron,diflubenzuron and benzoylurea in different fruit samples,i.e.pear,apple and banana,in the selected time region of chromatogram.The concentration,elution time and spectral information of these benzoylurea insecticides are selectively extracted from complex matrices even in the presence of unknown interferences.The root-mean-square error of prediction(RMSEP)and figures of merit,including sensitivity(SEN),selectivity(SEL)and limit of detection(LOD)are employed to access the performance of the method.The LODs obtained for these insecticides are within the range 0.017–0.26 ppm in pears,0.039–0.33 ppm in apples,0.041–0.44 ppm in bananas,respectively.Such a chemometrics-based protocol holds great potential to be extended as a promising alternative for more practical applications in food safety and quality monitoring.展开更多
A novel methodology that combines high performance liquid chromatography with photodiode-array detector (HPLC-DAD) coupled with second-order calibration method based on alternating trilinear decomposition (ATLD) a...A novel methodology that combines high performance liquid chromatography with photodiode-array detector (HPLC-DAD) coupled with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was used in determination of the effective constituents such as costunolide and dehydrocostuslactone, in plasma sample and Chinese patent medicine Xiang Sha Yang Wei (XSYW) capsule. Complicated systems such as plasma and Chinese patent medicine which have intricate components are tedious to isolate and purify. The problem that chromatographic peaks are heavily overlapped among the analytes and interferents from the background matrices can be resolved, and the satisfactory quantification results have been gained with the help of the ATLD algorithm which utilized "mathematical separation" instead of partial "physical or chemical separation". Meanwhile, HPLC-MS/MS method was used to validate the accuracy of the proposed determination method.展开更多
LiDAR and camera are two of the most common sensors used in the fields of robot perception,autonomous driving,augmented reality,and virtual reality,where these sensors are widely used to perform various tasks such as ...LiDAR and camera are two of the most common sensors used in the fields of robot perception,autonomous driving,augmented reality,and virtual reality,where these sensors are widely used to perform various tasks such as odometry estimation and 3D reconstruction.Fusing the information from these two sensors can significantly increase the robustness and accuracy of these perception tasks.The extrinsic calibration between cameras and LiDAR is a fundamental prerequisite for multimodal systems.Recently,extensive studies have been conducted on the calibration of extrinsic parameters.Although several calibration methods facilitate sensor fusion,a comprehensive summary for researchers and,especially,non-expert users is lacking.Thus,we present an overview of extrinsic calibration and discuss diverse calibration methods from the perspective of calibration system design.Based on the calibration information sources,this study classifies these methods as target-based or targetless.For each type of calibration method,further classification was performed according to the diverse types of features or constraints used in the calibration process,and their detailed implementations and key characteristics were introduced.Thereafter,calibration-accuracy evaluation methods are presented.Finally,we comprehensively compare the advantages and disadvantages of each calibration method and suggest directions for practical applications and future research.展开更多
A method for correlating thermal light over a wide spectral range is proposed.A multi-wavelength pseudothermal source,prepared by projecting laser beams of multiple wavelengths(650 nm,635 nm,532 nm,and 473 nm)onto a m...A method for correlating thermal light over a wide spectral range is proposed.A multi-wavelength pseudothermal source,prepared by projecting laser beams of multiple wavelengths(650 nm,635 nm,532 nm,and 473 nm)onto a moving thin ground glass plate,is employed in a double-slit interference experiment.The ground glass plate induces random phase differences between light beams of different wavelengths passing through it.This initial random phase difference significantly influences the high-order intensity correlation functions of multi-wavelength thermal beams.Experimentally,second-order correlated interference patterns,including subwavelength interference,of pseudothermal beams with different wavelengths are observed in the intensity correlation measurements.This method facilitates applications of correlated thermal photons in quantum information processing and quantum imaging.展开更多
Discriminative region localization and efficient feature encoding are crucial for fine-grained object recognition.However,existing data augmentation methods struggle to accurately locate discriminative regions in comp...Discriminative region localization and efficient feature encoding are crucial for fine-grained object recognition.However,existing data augmentation methods struggle to accurately locate discriminative regions in complex backgrounds,small target objects,and limited training data,leading to poor recognition.Fine-grained images exhibit“small inter-class differences,”and while second-order feature encoding enhances discrimination,it often requires dual Convolutional Neural Networks(CNN),increasing training time and complexity.This study proposes a model integrating discriminative region localization and efficient second-order feature encoding.By ranking feature map channels via a fully connected layer,it selects high-importance channels to generate an enhanced map,accurately locating discriminative regions.Cropping and erasing augmentations further refine recognition.To improve efficiency,a novel second-order feature encoding module generates an attention map from the fourth convolutional group of Residual Network 50 layers(ResNet-50)and multiplies it with features from the fifth group,producing second-order features while reducing dimensionality and training time.Experiments on Caltech-University of California,San Diego Birds-200-2011(CUB-200-2011),Stanford Car,and Fine-Grained Visual Classification of Aircraft(FGVC Aircraft)datasets show state-of-the-art accuracy of 88.9%,94.7%,and 93.3%,respectively.展开更多
In data communication,limited communication resources often lead to measurement bias,which adversely affects subsequent system estimation if not effectively handled.This paper proposes a novel bias calibration algorit...In data communication,limited communication resources often lead to measurement bias,which adversely affects subsequent system estimation if not effectively handled.This paper proposes a novel bias calibration algorithm under communication constraints to achieve accurate system states of the interested system.An output-based event-triggered scheme is first employed to alleviate transmission burden.Accounting for the limited-communication-induced measurement bias,a novel bias calibration algorithm following the Kalman filtering line is developed to restrain the effect of the measurement bias on system estimation,thereby achieving accurate system state estimates.Subsequently,the Field Programmable Gate Array(FPGA)implementation of the proposed algorithm is also realized with the hope of providing fast bias calibration in practical scenarios.A simulation about a numerical example and a practical example(for gyroscope’s angular velocity bias calibration)on MATLAB is provided to demonstrate the feasibility and effectiveness of the proposed algorithm.展开更多
We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-...We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.展开更多
Large-volume presses(LVPs)are widely utilized in diverse research fields—including high-pressure physics,chemistry,materials science,and Earth and planetary sciences—to investigate the physical and chemical properti...Large-volume presses(LVPs)are widely utilized in diverse research fields—including high-pressure physics,chemistry,materials science,and Earth and planetary sciences—to investigate the physical and chemical properties of materials under extreme high-pressure and hightemperature conditions.A prerequisite for achieving reproducible property measurements is the determination and control of pressure within experimental setups.However,the lack of precise pressure calibration in LVPs hinders the broader application of such devices in ultrahigh-pressure studies.This study employs a suite of standard phase transition-based pressure markers—comprising metallic conductors,semiconductors,and minerals—through both in situ and ex situ identification approaches,to establish pressure calibration curves ranging from 0.4 to>30 GPa for various types of LVP installed at the Center for High Pressure Science and Technology Advanced Research(HPSTAR),Beijing,including piston–cylinder,cubic,and multi-anvil presses.The results provide a unified and traceable pressure reference for highpressure experiments conducted at HPSTAR,while also offering technical guidance and calibration standards for other researchers utilizing similar LVP systems,thereby enabling more consistent comparison between different laboratories.This work facilitates the advancement of LVP research toward broader applications in higher-pressure regimes.展开更多
High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science ...High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment.展开更多
Currently,there is a lack of in-situ or model test results for cone penetration tests(CPTs)conducted in deep,dense sand layers under high overburden stresses,restricting the development of empirical relationships betw...Currently,there is a lack of in-situ or model test results for cone penetration tests(CPTs)conducted in deep,dense sand layers under high overburden stresses,restricting the development of empirical relationships between CPT results and the characteristics of such deep,dense sand layers.This study addresses this gap by proposing an empirical relationship to predict the relative density of dense silica sand based on stress level and cone tip resistance.The relationship was developed through CPTs performed in a calibration chamber using dense sand specimens(with relative densities of 74%-91%)subjected to high stresses(under overburden stresses of 0.5-2.0 MPa)and numerical simulations employing the large deformation finite element method.The Arbitrary Lagrangian Eulerian method was used to regularly regenerate the mesh to prevent soil element distortion around the cone tip.Additionally,the modified Mohr-Coulomb model was integrated to capture the stress-strain behavior of dense silica sand under high stresses.A reasonable agreement was achieved between the numerical and experimental penetration profiles,which verifies the reliability of the numerical model.A sufficient number of parametric analyses were carried out,and then an empirical equation was proposed to establish the relationship between the relative density of dense sand,stress level and cone resistance.The empirical equation provides predictions with acceptable accuracy,as the discrepancies between the predicted and measured relative density values fall within±30%.展开更多
Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of th...Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.展开更多
The response and performance of radiation detectors for accurate measurements and effective use for radiological safety in medical, industrial, and nuclear sectors are based on the optimal use, maintenance, repair and...The response and performance of radiation detectors for accurate measurements and effective use for radiological safety in medical, industrial, and nuclear sectors are based on the optimal use, maintenance, repair and calibration of radiation monitoring instruments in a secondary standard dosimetry laboratory. In Nigeria, the suboptimal performances of these instruments are attributed to inadequate maintenance practices, insufficient calibration, and limited awareness of proper equipment handling for optimal use. This study assesses the current practices related to the optimal use, maintenance, repair, and calibration of radiation detection equipment across Nigeria’s six geopolitical zones. Using a cross-sectional survey approach, data were collected from Ninety (90) radiation monitoring equipment operators, Radiation Safety Officers, and frontline responders to evaluate their knowledge, awareness, and practices concerning equipment usage, operation, storage, handling, and calibration. The findings reveal significant gaps in knowledge of usage (trained is 43.2%, not trained is 56.8%) and inconsistencies in maintenance practices (as indicated by the regression analysis (β = 0.51, p < 0.01), particularly regarding specialized instruments such as the PackEye, Mobile Detection System (MDS), Radionuclide Identifinder (RID), and Personal Radiation Detectors (PRD). While there is high awareness of the need for regular calibration and handling training, the lack of standardized protocols and training alignment poses challenges to the effective use of these instruments. This study underscores the importance of comprehensive training programs, standardized maintenance protocols, and enhanced awareness initiatives to optimize the usage, performance and safety of radiation monitoring instruments in Nigeria.展开更多
Radiation detectors, such as survey meters, are essential for ensuring radiation safety in various sectors, including healthcare, industrial processing, emergency response, etc. However, regular calibration and proper...Radiation detectors, such as survey meters, are essential for ensuring radiation safety in various sectors, including healthcare, industrial processing, emergency response, etc. However, regular calibration and proper maintenance of survey meters are important in order to ascertain their accuracy and reliability. This study provides a comprehensive retrospective assessment of the calibration behaviour, durability, and fault trends of 160 survey meters, spanning ten different models. They were calibrated at the Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria over a decade (2012-2023) using an X-Ray Beam Irradiator Model X80-225K and Cs-137 irradiator (OB6) with a PTW reference spherical chamber traceable to the IAEA SSDL in Seibersdorf, Austria. The calibration stability of each model was evaluated, revealing that models like Instrument A and Instrument B demonstrated high reliability with calibration factors close to the ideal value of 1, while models like Instrument C exhibited higher variability, suggesting less consistent performance for dose rate monitoring. Fault analysis showed that the most common issues were related to the battery compartment, indicating a need for improved handling practices. Correlation analysis reveals no statistically significant correlation between calibration factor and age of survey meter across the analysed models. The study concludes that regular calibration, proper handling, and user training are crucial for maintaining the accuracy and longevity of radiation detectors.展开更多
In various imaging applications such as autonomous vehicles and drones,autofocus lenses are indispensable for capturing clear images.However,conventional camera calibration methods typically rely either on processing ...In various imaging applications such as autonomous vehicles and drones,autofocus lenses are indispensable for capturing clear images.However,conventional camera calibration methods typically rely either on processing multiple images at a fixed focal length or on detecting multi-plane markers in a single image and then applying multi-image calibration models.This paper proposes a flexible and accurate calibration approach that extracts subpixel saddle points from a single image containing three non-coplanar calibration boards.To compute accurate homography matrices for the three boards,outliers are removed by eliminating chessboard points that deviated from the fitted grid lines according to their row and column positions.Initial estimates of the intrinsic parameters and the poses of the three planar chessboards are obtained using the three homography matrices in combination with Zhang’s calibration method.During parameter refinement,a multi-objective optimization function is constructed,incorporating three error terms:(1)Reprojection error of the inlier grid points;(2)Mechanism-driven error derived from the relationship between homography matrices and camera parameters;(3)Cross-planar linearity constraint error,which preserves the pre-imaging collinearity of any five points across different planes after projection.For weight selection in the optimization process,confidence intervals of the detected grid points are analyzed by horizontally rotating the reprojection lines to reduce bias introduced by line slope.The optimal weights are determined by minimizing the number of points whose confidence intervals does not intersect the reprojected lines.When multiple candidates yield similar reprojection performance,the parameter set with the smallest reprojection error is selected as the final result.This method efficiently estimates both intrinsic and extrinsic camera parameters.Simulations and real-world experiments validate the high precision and effectiveness of the proposed approach.Our technique is straightforward,practical,and holds significant theoretical and practical value for rapid and reliable camera calibration.展开更多
In clinical environments,the prolonged utilization of polarization equipment can result in theaccumulation of errors over extended periods.The absence of expeditious calibration techniques in clinical practice present...In clinical environments,the prolonged utilization of polarization equipment can result in theaccumulation of errors over extended periods.The absence of expeditious calibration techniques in clinical practice presents a significant obstacle in preserving the precision and dependability of these instruments.To address this challenge,we propose an innovative research study that presents a comprebersive calibration system specifically designed for the calibration of the backscattering Muellet matrix measurement system,enabling swift online calibration acroes various scenarios.This system employs an external calibration framework for rmal-time adjust-ment of the polarizer's initial angle,oversecing the rotation of PSG and PSA motors through position measurement and control procedures,with light intensity monitored by a camera.By incorporating moment um concepts and the Adam optimization algorithm,we enhance conver-gence speed,mitigate noise,and improve calibration accuracy.Experimental results showcase the exceptional precision,speed,and robustness of oрroposed method,achieving high acсuracy and minimal error,thereby offering a promising solution for maintaining the reliabilit y of polarization equipment in clinical settings.展开更多
基金financially supported by The National Natural Science Foundation of China(No.20775025)The National Basic Research Program(No.2007CB216404) as well as PCSIRT
文摘A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD (alternating penalty trilinear decomposition) algorithm was proposed to analyze the three-way HPLC-DAD data from both standard and prediction samples, which makes it possible that calibration can be performed even in the presence of unknown interferences with a simple and green chromatographic condition and short analysis time. The results showed that good recoveries were obtained although the chromatographic and spectral profiles of the analytes of interest as well as background were partially overlapped with each other in plasma samples.
基金the National Natural Science Foundation of China (Grant No. 21175041)the National Basic Research Program (Grant No. 2012CB910602)Program for Changjiang Scholars and Innovative Research Team in University (PCSIRT) for financial supports
文摘The effectiveness of traditional Chinese medicine(TCM)against various diseases urges more low cost,speed and sensitive analytical methods for investigating the phamacology of TCM and providing a theoretical basis for clinical use.The potential of second-order calibration method was validated for the quantification of two effective ingredients of Schisandra chinensis in human plasma using spectrofluorimetry.The results obtained in the present study demonstrate the advantages of this strategy for multi-target determination in complex matrices.Although the spectra of the analytes are similar and a large number of interferences also exist,second-order calibration method could predict the accurate concentrations together with reasonable resolution of spectral profiles for analytes of interest owing to its‘second-order advantage’.Moreover,the method presented in this work allows one to simply experimental procedure as well as reduces the use of harmful chemical solvents.
基金National Natural Science Foundation of China(No.21175041)the National Basic Research Program(No.2012CBg10602)
文摘A "green" and quick analytical method for complex compounds was developed for simultaneous determination of tyrosine (Tyr) and dopamine (DA) in urine samples in this paper. The three-way responsive data recorded by excitation-emission matrix fluorescence (EEM) spectrometer was analyzed using second-order calibration methods based on both parallel factor analysis (PARAFAC) and self- weighted alternating trilinear decomposition (SWATLD) algorithms. The EEM spectra of the analytes were overlapped with the background in urine samples. However the second-order advantage of both PARAFAC and SWATLD methods was exploited, even in the presence of unknown interferences and the satisfactory results can be obtained. Furthermore, the linear ranges of Tyr and DA were determined to be 0.042-6.42 p.g/mL and 0.18-4.43/ug]mL, respectively, and the accuracies of both methods were validated by the analytical figures of merit (FOM).
基金support from the National Natural Science Foundation of China(Grants Nos.21776321,21576297,21205145,21575039)Key Projects of Technological Innovation of Hubei Province(2016ACA138)The Open Research Program(Grant Nos.2015ZD001,2015ZD002 and 2015ZY006)。
文摘An HPLC-DAD method combined with second-order calibration based on the alternating trilinear decomposition(ATLD)algorithm with the aid of region selection was developed to simultaneously and quantitatively characterize the synergistic relationships and cumulative excretion of the four bioactive ingredients of Radix Gentianae Macrophyllae in vivo.Although the analytes spectra substantially overlapped with that of the biological matrix,the overlapping profiles between analytes and co-eluting interferences can be successfully separated and accurately quantified by the ATLD method on the basis of the strength of region selection.The proposed approach not only determined the content change but also revealed the synergistic relationships and the cumulative excretion in vivo of the four ingredients in urine and feces samples collected at different excretion time intervals.In addition,several statistical parameters were employed to evaluate the accuracy and precision of the method.Quantitative results were confirmed by HPLC-mass spectrometry.Satisfactory results indicated that the proposed approach can be utilized to investigate the pharmacokinetics of Radix Gentianae Macrophyllae excretion in vivo.
基金the financial supports from the National Natural Science Foundation of China(No.21175041)the National Basic Research Program of China(No.2012CB910602)the Foundation for Innovative Research Groups of NSFC(No.21221003)
文摘A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled with second-order calibration method based on the alternating trilinear decomposition(ATLD) algorithm, the proposed approach can achieve quantitative analysis successfully even in the presence of unknown and uncalibrated interferences. The method shows good linearity for NAP and VB6 with correlation coefficients greater than 0.99. The results were in good agreement with the labeled contents. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring(MRM) based on LC–MS/MS method.T-test demonstrated that there are no significant differences between the prediction results of the two methods. The satisfactory results obtained in this work indicate that the use of the second-order calibration method coupled with the EEM is a promising tool for industrial quality control and pharmaceutical analysis due to its advantages of high sensitivity, low-cost and simple implementation.
基金the National Natural Science Foundation of China(21175041)the National Basic Research Program(2012CB910602)for financial supports
文摘This work presents a novel application of second-order calibration based on self-weighted alternating trilinear decomposition(SWATLD)algorithm for analyzing the HPLC-DAD data.The proposed method makes it possible to simultaneously determine teflubenzuron,hexaflumuron,flufenoxuron,chlorfluazuron,diflubenzuron and benzoylurea in different fruit samples,i.e.pear,apple and banana,in the selected time region of chromatogram.The concentration,elution time and spectral information of these benzoylurea insecticides are selectively extracted from complex matrices even in the presence of unknown interferences.The root-mean-square error of prediction(RMSEP)and figures of merit,including sensitivity(SEN),selectivity(SEL)and limit of detection(LOD)are employed to access the performance of the method.The LODs obtained for these insecticides are within the range 0.017–0.26 ppm in pears,0.039–0.33 ppm in apples,0.041–0.44 ppm in bananas,respectively.Such a chemometrics-based protocol holds great potential to be extended as a promising alternative for more practical applications in food safety and quality monitoring.
文摘A novel methodology that combines high performance liquid chromatography with photodiode-array detector (HPLC-DAD) coupled with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was used in determination of the effective constituents such as costunolide and dehydrocostuslactone, in plasma sample and Chinese patent medicine Xiang Sha Yang Wei (XSYW) capsule. Complicated systems such as plasma and Chinese patent medicine which have intricate components are tedious to isolate and purify. The problem that chromatographic peaks are heavily overlapped among the analytes and interferents from the background matrices can be resolved, and the satisfactory quantification results have been gained with the help of the ATLD algorithm which utilized "mathematical separation" instead of partial "physical or chemical separation". Meanwhile, HPLC-MS/MS method was used to validate the accuracy of the proposed determination method.
基金Supported by Beijing Natural Science Foundation(Grant No.L241012)the National Natural Science Foundation of China(Grant No.62572468).
文摘LiDAR and camera are two of the most common sensors used in the fields of robot perception,autonomous driving,augmented reality,and virtual reality,where these sensors are widely used to perform various tasks such as odometry estimation and 3D reconstruction.Fusing the information from these two sensors can significantly increase the robustness and accuracy of these perception tasks.The extrinsic calibration between cameras and LiDAR is a fundamental prerequisite for multimodal systems.Recently,extensive studies have been conducted on the calibration of extrinsic parameters.Although several calibration methods facilitate sensor fusion,a comprehensive summary for researchers and,especially,non-expert users is lacking.Thus,we present an overview of extrinsic calibration and discuss diverse calibration methods from the perspective of calibration system design.Based on the calibration information sources,this study classifies these methods as target-based or targetless.For each type of calibration method,further classification was performed according to the diverse types of features or constraints used in the calibration process,and their detailed implementations and key characteristics were introduced.Thereafter,calibration-accuracy evaluation methods are presented.Finally,we comprehensively compare the advantages and disadvantages of each calibration method and suggest directions for practical applications and future research.
基金supported by the National Natural Science Foundation of China(Grant Nos.62105278 and 11674273)the Natural Science Foundation of Shandong Province(Grant No.ZR2023MA015)。
文摘A method for correlating thermal light over a wide spectral range is proposed.A multi-wavelength pseudothermal source,prepared by projecting laser beams of multiple wavelengths(650 nm,635 nm,532 nm,and 473 nm)onto a moving thin ground glass plate,is employed in a double-slit interference experiment.The ground glass plate induces random phase differences between light beams of different wavelengths passing through it.This initial random phase difference significantly influences the high-order intensity correlation functions of multi-wavelength thermal beams.Experimentally,second-order correlated interference patterns,including subwavelength interference,of pseudothermal beams with different wavelengths are observed in the intensity correlation measurements.This method facilitates applications of correlated thermal photons in quantum information processing and quantum imaging.
基金supported,in part,by the National Nature Science Foundation of China under Grant 62272236,62376128 and 62306139the Natural Science Foundation of Jiangsu Province under Grant BK20201136,BK20191401.
文摘Discriminative region localization and efficient feature encoding are crucial for fine-grained object recognition.However,existing data augmentation methods struggle to accurately locate discriminative regions in complex backgrounds,small target objects,and limited training data,leading to poor recognition.Fine-grained images exhibit“small inter-class differences,”and while second-order feature encoding enhances discrimination,it often requires dual Convolutional Neural Networks(CNN),increasing training time and complexity.This study proposes a model integrating discriminative region localization and efficient second-order feature encoding.By ranking feature map channels via a fully connected layer,it selects high-importance channels to generate an enhanced map,accurately locating discriminative regions.Cropping and erasing augmentations further refine recognition.To improve efficiency,a novel second-order feature encoding module generates an attention map from the fourth convolutional group of Residual Network 50 layers(ResNet-50)and multiplies it with features from the fifth group,producing second-order features while reducing dimensionality and training time.Experiments on Caltech-University of California,San Diego Birds-200-2011(CUB-200-2011),Stanford Car,and Fine-Grained Visual Classification of Aircraft(FGVC Aircraft)datasets show state-of-the-art accuracy of 88.9%,94.7%,and 93.3%,respectively.
基金support from the National Natural Science Foundation of China(Grant Nos.U2330206,U2230206,62173068)Sichuan Science and Technology Program(Grants Nos.2024NSFSC1483,2024ZYD0156,2023NSFC1962,DQ202412).
文摘In data communication,limited communication resources often lead to measurement bias,which adversely affects subsequent system estimation if not effectively handled.This paper proposes a novel bias calibration algorithm under communication constraints to achieve accurate system states of the interested system.An output-based event-triggered scheme is first employed to alleviate transmission burden.Accounting for the limited-communication-induced measurement bias,a novel bias calibration algorithm following the Kalman filtering line is developed to restrain the effect of the measurement bias on system estimation,thereby achieving accurate system state estimates.Subsequently,the Field Programmable Gate Array(FPGA)implementation of the proposed algorithm is also realized with the hope of providing fast bias calibration in practical scenarios.A simulation about a numerical example and a practical example(for gyroscope’s angular velocity bias calibration)on MATLAB is provided to demonstrate the feasibility and effectiveness of the proposed algorithm.
基金supported by National Key R&D grant from the Ministry of Science and Technology of China(Nos.2021YFA1601600,2023YFA1606200)National Science Foundation of China(Nos.12090062,12105008)the Major State Basic Research Development Program of China.
文摘We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.
基金supported by the National Science Foundation of China(Grant Nos.U1530402 and U1930401).
文摘Large-volume presses(LVPs)are widely utilized in diverse research fields—including high-pressure physics,chemistry,materials science,and Earth and planetary sciences—to investigate the physical and chemical properties of materials under extreme high-pressure and hightemperature conditions.A prerequisite for achieving reproducible property measurements is the determination and control of pressure within experimental setups.However,the lack of precise pressure calibration in LVPs hinders the broader application of such devices in ultrahigh-pressure studies.This study employs a suite of standard phase transition-based pressure markers—comprising metallic conductors,semiconductors,and minerals—through both in situ and ex situ identification approaches,to establish pressure calibration curves ranging from 0.4 to>30 GPa for various types of LVP installed at the Center for High Pressure Science and Technology Advanced Research(HPSTAR),Beijing,including piston–cylinder,cubic,and multi-anvil presses.The results provide a unified and traceable pressure reference for highpressure experiments conducted at HPSTAR,while also offering technical guidance and calibration standards for other researchers utilizing similar LVP systems,thereby enabling more consistent comparison between different laboratories.This work facilitates the advancement of LVP research toward broader applications in higher-pressure regimes.
文摘High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment.
基金National Natural Science Foundation of China(Nos.42025702,52394251)。
文摘Currently,there is a lack of in-situ or model test results for cone penetration tests(CPTs)conducted in deep,dense sand layers under high overburden stresses,restricting the development of empirical relationships between CPT results and the characteristics of such deep,dense sand layers.This study addresses this gap by proposing an empirical relationship to predict the relative density of dense silica sand based on stress level and cone tip resistance.The relationship was developed through CPTs performed in a calibration chamber using dense sand specimens(with relative densities of 74%-91%)subjected to high stresses(under overburden stresses of 0.5-2.0 MPa)and numerical simulations employing the large deformation finite element method.The Arbitrary Lagrangian Eulerian method was used to regularly regenerate the mesh to prevent soil element distortion around the cone tip.Additionally,the modified Mohr-Coulomb model was integrated to capture the stress-strain behavior of dense silica sand under high stresses.A reasonable agreement was achieved between the numerical and experimental penetration profiles,which verifies the reliability of the numerical model.A sufficient number of parametric analyses were carried out,and then an empirical equation was proposed to establish the relationship between the relative density of dense sand,stress level and cone resistance.The empirical equation provides predictions with acceptable accuracy,as the discrepancies between the predicted and measured relative density values fall within±30%.
基金Support by Sichuan Science and Technology Program[2023YFSY0026,2023YFH0004].
文摘Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.
文摘The response and performance of radiation detectors for accurate measurements and effective use for radiological safety in medical, industrial, and nuclear sectors are based on the optimal use, maintenance, repair and calibration of radiation monitoring instruments in a secondary standard dosimetry laboratory. In Nigeria, the suboptimal performances of these instruments are attributed to inadequate maintenance practices, insufficient calibration, and limited awareness of proper equipment handling for optimal use. This study assesses the current practices related to the optimal use, maintenance, repair, and calibration of radiation detection equipment across Nigeria’s six geopolitical zones. Using a cross-sectional survey approach, data were collected from Ninety (90) radiation monitoring equipment operators, Radiation Safety Officers, and frontline responders to evaluate their knowledge, awareness, and practices concerning equipment usage, operation, storage, handling, and calibration. The findings reveal significant gaps in knowledge of usage (trained is 43.2%, not trained is 56.8%) and inconsistencies in maintenance practices (as indicated by the regression analysis (β = 0.51, p < 0.01), particularly regarding specialized instruments such as the PackEye, Mobile Detection System (MDS), Radionuclide Identifinder (RID), and Personal Radiation Detectors (PRD). While there is high awareness of the need for regular calibration and handling training, the lack of standardized protocols and training alignment poses challenges to the effective use of these instruments. This study underscores the importance of comprehensive training programs, standardized maintenance protocols, and enhanced awareness initiatives to optimize the usage, performance and safety of radiation monitoring instruments in Nigeria.
文摘Radiation detectors, such as survey meters, are essential for ensuring radiation safety in various sectors, including healthcare, industrial processing, emergency response, etc. However, regular calibration and proper maintenance of survey meters are important in order to ascertain their accuracy and reliability. This study provides a comprehensive retrospective assessment of the calibration behaviour, durability, and fault trends of 160 survey meters, spanning ten different models. They were calibrated at the Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria over a decade (2012-2023) using an X-Ray Beam Irradiator Model X80-225K and Cs-137 irradiator (OB6) with a PTW reference spherical chamber traceable to the IAEA SSDL in Seibersdorf, Austria. The calibration stability of each model was evaluated, revealing that models like Instrument A and Instrument B demonstrated high reliability with calibration factors close to the ideal value of 1, while models like Instrument C exhibited higher variability, suggesting less consistent performance for dose rate monitoring. Fault analysis showed that the most common issues were related to the battery compartment, indicating a need for improved handling practices. Correlation analysis reveals no statistically significant correlation between calibration factor and age of survey meter across the analysed models. The study concludes that regular calibration, proper handling, and user training are crucial for maintaining the accuracy and longevity of radiation detectors.
基金supported by the Research on the Reform of Curriculum Assessment Methods for College Mathematics Platform Courses(No.53111104016)。
文摘In various imaging applications such as autonomous vehicles and drones,autofocus lenses are indispensable for capturing clear images.However,conventional camera calibration methods typically rely either on processing multiple images at a fixed focal length or on detecting multi-plane markers in a single image and then applying multi-image calibration models.This paper proposes a flexible and accurate calibration approach that extracts subpixel saddle points from a single image containing three non-coplanar calibration boards.To compute accurate homography matrices for the three boards,outliers are removed by eliminating chessboard points that deviated from the fitted grid lines according to their row and column positions.Initial estimates of the intrinsic parameters and the poses of the three planar chessboards are obtained using the three homography matrices in combination with Zhang’s calibration method.During parameter refinement,a multi-objective optimization function is constructed,incorporating three error terms:(1)Reprojection error of the inlier grid points;(2)Mechanism-driven error derived from the relationship between homography matrices and camera parameters;(3)Cross-planar linearity constraint error,which preserves the pre-imaging collinearity of any five points across different planes after projection.For weight selection in the optimization process,confidence intervals of the detected grid points are analyzed by horizontally rotating the reprojection lines to reduce bias introduced by line slope.The optimal weights are determined by minimizing the number of points whose confidence intervals does not intersect the reprojected lines.When multiple candidates yield similar reprojection performance,the parameter set with the smallest reprojection error is selected as the final result.This method efficiently estimates both intrinsic and extrinsic camera parameters.Simulations and real-world experiments validate the high precision and effectiveness of the proposed approach.Our technique is straightforward,practical,and holds significant theoretical and practical value for rapid and reliable camera calibration.
基金the Knowledge Innovation Program of Basic Re-search Projects of Shenzhen for their support under Grant No.JCYJ20200109142805928the funding provided by the Basic and Applied Basic Research Foundation of Guangdong Provinæunder Grant No.2021A1515220113partially supported by the Guangzhou Municipal Science and Technology Project under Grant 202102010421.
文摘In clinical environments,the prolonged utilization of polarization equipment can result in theaccumulation of errors over extended periods.The absence of expeditious calibration techniques in clinical practice presents a significant obstacle in preserving the precision and dependability of these instruments.To address this challenge,we propose an innovative research study that presents a comprebersive calibration system specifically designed for the calibration of the backscattering Muellet matrix measurement system,enabling swift online calibration acroes various scenarios.This system employs an external calibration framework for rmal-time adjust-ment of the polarizer's initial angle,oversecing the rotation of PSG and PSA motors through position measurement and control procedures,with light intensity monitored by a camera.By incorporating moment um concepts and the Adam optimization algorithm,we enhance conver-gence speed,mitigate noise,and improve calibration accuracy.Experimental results showcase the exceptional precision,speed,and robustness of oрroposed method,achieving high acсuracy and minimal error,thereby offering a promising solution for maintaining the reliabilit y of polarization equipment in clinical settings.