期刊文献+
共找到469篇文章
< 1 2 24 >
每页显示 20 50 100
Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing 被引量:1
1
作者 Brennen L. Lucas Alexander C.M. Chong +2 位作者 Bruce R. Buhr Teresa L. Jones Paul H. Wooley 《Journal of Biomedical Science and Engineering》 2011年第4期235-241,共7页
Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability,... Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed. 展开更多
关键词 BIOMECHANICAL locking screwS INTRAMEDULLARY NAIL DISTAL TIBIA
暂未订购
The Effects of Bone Screw Configurations on the Interfragmentary Movement in a Long Bone Fixed by a Limited Contact Locking Compression Plate
2
作者 Jalil Nourisa Amin Baseri +1 位作者 Leszek Sudak Gholamreza Rouhi 《Journal of Biomedical Science and Engineering》 2015年第9期590-600,共11页
The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the funct... The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain. 展开更多
关键词 Long BONE Fracture lockING Compression Plate Interfragmentary Strain screw Density screw Position
暂未订购
基于NordLock楔锁原理的双螺母滚珠丝杠副的创新设计与性能分析 被引量:1
3
作者 刘莉 姜洪奎 +4 位作者 周亮 田博丞 宋现春 李彦凤 宋米佳 《制造技术与机床》 北大核心 2020年第11期56-60,67,共6页
针对国产滚珠丝杠副常常出现的因加工误差、滚道磨损等因素导致的预紧力丧失的难题,将NordLock楔锁特征应用于滚珠丝杠副的结构设计中,提出了一种新型预紧滚珠丝杠副。该预紧机构由左、右两个楔锁垫片组成,使双螺母与丝杠轴产生相对位移... 针对国产滚珠丝杠副常常出现的因加工误差、滚道磨损等因素导致的预紧力丧失的难题,将NordLock楔锁特征应用于滚珠丝杠副的结构设计中,提出了一种新型预紧滚珠丝杠副。该预紧机构由左、右两个楔锁垫片组成,使双螺母与丝杠轴产生相对位移,从而产生轴向预紧力;同时,两垫片的楔锁效应使得预紧力大小保持不变。根据楔锁效应和滚珠丝杠副的结构参数,确定了楔形预紧垫片的关键结构参数。应用SolidWorks建立了三维几何模型,应用Ansys有限元软件对新型滚珠丝杠副进行了瞬态动力学分析和模态分析。结果表明,这种新型结构能够有效地实现自我预紧,有望成为一种具有良好应用前景的高可靠性、长寿命的滚珠丝杠副。 展开更多
关键词 楔锁效应 滚珠丝杠副 预紧 有限元 Nordlock
在线阅读 下载PDF
髓内钉治疗股骨干骨折过程中改良矩形锁定装置的应用
4
作者 张平 周大方 +3 位作者 陈辉 张莹 刘青 史册 《中国组织工程研究》 北大核心 2026年第21期5510-5516,共7页
背景:矩形框架式瞄准器分左、右2个模块,不利于术中灵活使用,容易产生形变和误差,连接完成后仍需要反复透视确认进行螺钉的钻孔、置入。目的:探讨改良矩形锁定装置在股骨干骨折髓内钉治疗时精准置入远端锁钉的关键技术研发及临床应用效... 背景:矩形框架式瞄准器分左、右2个模块,不利于术中灵活使用,容易产生形变和误差,连接完成后仍需要反复透视确认进行螺钉的钻孔、置入。目的:探讨改良矩形锁定装置在股骨干骨折髓内钉治疗时精准置入远端锁钉的关键技术研发及临床应用效果。方法:收集徐州医科大学附属宿迁医院和宿豫区人民医院2021-2023年收治的股骨干骨折患者的病历资料,选择18-65岁、经影像学检查确诊为股骨干骨折(AO分型:A、B或C型)、接受闭合复位髓内钉内固定治疗且术中采用改良矩形锁定装置置入远端锁钉的患者;临床资料(包括病史、影像学、手术记录、随访记录等)完整。符合条件的病例有41例,其中男30例,女11例;年龄20-62岁,平均(41.17±8.14)岁。收集术中远端锁钉置入时透视次数、锁定成功率、远端锁钉成功置入时间、术后1个月和骨折愈合后美国膝关节协会评分及骨折愈合时间。结果与结论:①41例患者均采用改良矩形锁定装置置入远端锁钉,术中远端锁钉置入时透视次数0-2次,平均(1.1±0.5)次;锁定成功率为98%;远端锁钉成功置入时间6-10 min,平均(7.0±1.5)min;术后1个月膝关节美国膝关节协会评分140-190分,平均(150±15)分;②有38例患者获得完整随访,随访时间12-24个月,骨折愈合时间9-14个月,平均(10.5±2.5)个月,骨折愈合后膝关节美国膝关节协会评分150-190分,平均(185±8)分,其中优35例,良3例;③结果表明,相较于徒手锁定远端锁钉、斜位透视置入远端锁钉、关节镜辅助置入远端锁钉、电磁导航锁定远端锁钉这几种方式置入股骨髓内钉远端锁钉,改良矩形锁定装置应用于髓内钉治疗股骨干骨折时置入远端锁钉的优势包括不依赖关节镜、电磁导航设备,不需要丰富的手术经验,步骤简单、锁定准确、可重复性高及减少辐射暴露。 展开更多
关键词 股骨干骨折 髓内钉 锁钉置入 内固定 改良矩形锁定装置 矩形框架式瞄准器 徒手置钉 斜位透视置钉 关节镜辅助置钉 电磁导航
暂未订购
纠偏压杆技术在顺行股骨髓内钉远端锁钉初次失败时的应用
5
作者 贺智榆 万志宏 +5 位作者 黄宇 刘安铭 吴佳奇 汪国友 张磊 陈孝均 《中国组织工程研究》 北大核心 2026年第21期5503-5509,共7页
背景:交锁髓内钉内固定是治疗股骨干骨折的“金标准”,而远端锁钉置入困难一直是难以解决的问题。目的:通过对比纠偏压杆技术与徒手锁钉技术的临床效果,进一步说明纠偏压杆技术是否能够快速、准确、无直接X射线辐射暴露地置入股骨髓内... 背景:交锁髓内钉内固定是治疗股骨干骨折的“金标准”,而远端锁钉置入困难一直是难以解决的问题。目的:通过对比纠偏压杆技术与徒手锁钉技术的临床效果,进一步说明纠偏压杆技术是否能够快速、准确、无直接X射线辐射暴露地置入股骨髓内钉远端锁钉,从而解决远端锁钉置入困难的问题。方法:纳入2022年7月至2024年9月西南医科大学附属中医医院骨伤科收治的股骨干骨折患者,在行股骨交锁髓内钉内固定时出现远端锁钉置入困难的病例共计52例,根据置入方案分为2组,纠偏压杆组26例采用纠偏压杆技术进行股骨髓内钉远端锁钉的置入,徒手锁钉组26例采用传统的徒手锁钉技术进行股骨髓内钉远端锁钉的置入。对比两组患者的远端锁钉置入时间、X射线投射次数及首次远端置钉准确率。结果与结论:①纠偏压杆组的远端锁钉置入时间明显短于徒手锁钉组(t=-4.136,P<0.001),差异有显著性意义;②纠偏压杆组X射线透视次数少于徒手锁钉组(t=-19.696,P<0.001),差异有显著性意义;③在两组首次置钉准确率方面,纠偏压杆组(100%)高于徒手锁钉组(71%),差异有显著性意义(χ^(2)=5.253,P<0.05);④结果表明,相较于单纯徒手置钉,纠偏压杆技术具有锁钉快、准确率高、X射线辐射小的优点,该技术无需辅助其他设备、可操作性强,值得进行进一步临床验证后推广应用于股骨干骨折股骨交锁髓内钉内固定。 展开更多
关键词 股骨骨折 股骨交锁髓内钉 内固定 远端锁钉 徒手锁钉 纠偏压杆技术 定位斯氏针
暂未订购
自动锁螺丝机的模态分析及结构设计优化
6
作者 罗震 戴伟 +4 位作者 李平 李良玉 李望俊 夏浩宇 吴晓 《武汉纺织大学学报》 2026年第1期8-14,共7页
针对如何优化自动锁螺丝机的结构从而避免共振的问题,文章提出一种基于ANSYS软件指导结构优化的方法。通过模态分析评估了锁付模块在额定工况下的应力分布、结构变形及固有频率等参数,旨在判断其结构共振可能性。结合振型参与系数及灵... 针对如何优化自动锁螺丝机的结构从而避免共振的问题,文章提出一种基于ANSYS软件指导结构优化的方法。通过模态分析评估了锁付模块在额定工况下的应力分布、结构变形及固有频率等参数,旨在判断其结构共振可能性。结合振型参与系数及灵敏度分析,对锁付模块实施了多零件多尺寸的优化设计。优化后的锁付模块经静动态特性有限元分析显示,重量降低了6.8%,且前6阶固有频率均避开主要激振频率,避开范围超过15%,达到了避免共振的研究目的。 展开更多
关键词 ANSYS 自动锁螺丝机 振型参与系数 灵敏度分析 模态分析
在线阅读 下载PDF
Can a Subcapital Osteotomy Fixed with an Intramedullary Locking Plate Correct all Possible Deformities of a Mild to Moderate Hallux Valgus?
7
作者 Michael Vitek Hannes Kugler +1 位作者 Felix Fink Ornella Vitek 《Open Journal of Orthopedics》 2017年第9期254-283,共30页
Background: There are at least 5 very popular methods described for the correction of mild to moderate hallux valgus deformities. Despite of reported and self experienced good results in favorable fitting preoperative... Background: There are at least 5 very popular methods described for the correction of mild to moderate hallux valgus deformities. Despite of reported and self experienced good results in favorable fitting preoperative anatomical conditions of some of these methods;it seems that no one is really satisfying under “difficult” or non favorable preoperative anatomic conditions. How could an optimum operation method for a satisfying correction of a mild to moderate hallux valgus look like? The well known criteria for an optimally satisfying method to achieve full normalization of important forefoot parameters under all conditions should be a lateralization, plantarization and derotation of the Ist metatarsal head and also a normalization of the distal metatarsal articular angle (DMAA) in combination with a soft tissue correction. Methods: In order to achieve this outcome without the disadvantages of shortening or the need for unloading, we developed a new operation technique and new fixation devices. We performed a simple transverse lazy-L subcapital osteotomy and after an additional soft tissue release the Ist metatarsal head was restored to its preplaned optimum position in terms of narrowing the IM angle, plantarization, correction of the hallux valgus angle, derotation of a pronation l malrotation and improvement of the DMAA. Fixation was achieved with an intramedullary angel-stable transfixed 30 mm titanium plate. The rigidity of the implant rendered interfragmental compression or solid bone contact unnecessary. The goal was only an optimal correction. All patients were allowed to ambulate with full weightbearing immediately after the operation. Results: We retrospectively reviewed 346 patients (433 feet) who underwent subcapital osteotomy between May 2007 and December 2011;308 were women and 38 men;their mean age was 65 years. The follow-up investigation was performed on average after 6.5 years (78 months);range 5.5 to 10 years (66 to 120 months). The AOFAS Score improved from 61.18 to 96.82 (t = 55.13, p ° to 4.21° (t = 89.70, p ° to 7.75° (t = 51.68, p ° to 6.61° (t = 29.34, p < 0.001). Minimal shortening of the first metatarsal (0.33 mm) and no recurrence of the deformity was observed. Conclusion: A new access to hallux valgus surgery is presented. Our results show that interfragmental compression between the osteotomy partners or good interfragmental contact is not necessary when a rigid intramedullary fixation device is used. The goal of this approach to hallux valgus surgery was to achieve excellent correction and a very rigid intramedullary angle-stable locked implant. The procedure yielded excellent results and was associated with no recurrence of hallux valgus. 展开更多
关键词 HALLUX VALGUS MILD MODERATE Toe Deformity Lateralization Plantarization Derotation Improvement of DMAA Full Weightbearing HALLUX VALGUS Surgery New Access Lazy-L OSTEOTOMY Soft Tissue Correction IM-Angle Angle-Stable locking screws INTRAMEDULLARY locking Plate
暂未订购
基于机器视觉的多规格螺丝锁付系统 被引量:1
8
作者 张雷 陆东 +3 位作者 刘申 张金辉 秦亚敏 李欣 《工业仪表与自动化装置》 2025年第5期12-17,123,共7页
针对小批量、变种类、多规格及小体积工件装配时螺丝锁付作业效率低、精度差的问题,研发了基于机器视觉的多规格螺丝锁付系统,通过机器视觉单元对工件表面螺纹孔进行识别定位,通过运动控制单元、螺丝锁付单元、供压单元、质量检测单元... 针对小批量、变种类、多规格及小体积工件装配时螺丝锁付作业效率低、精度差的问题,研发了基于机器视觉的多规格螺丝锁付系统,通过机器视觉单元对工件表面螺纹孔进行识别定位,通过运动控制单元、螺丝锁付单元、供压单元、质量检测单元以及通信单元的协同作业,完成螺丝锁付及质检作业。搭建了实验平台,并以表面螺纹孔为m2的工件为实验对象进行实验,结果表明,该系统可满足小型螺纹孔锁付的装配要求,有效地解决了人工作业时遗漏等问题,对机器视觉技术应用于小型工件装配工序提供了一定的实用价值。 展开更多
关键词 多规格 装配 螺丝锁付 机器视觉 识别定位
在线阅读 下载PDF
内外侧联合入路内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折疗效分析
9
作者 陈文韬 白晓冬 +7 位作者 刘振宇 高化 王刚 许国强 马骥 王稼田 王逸骏 王宝军 《中国骨与关节损伤杂志》 2025年第10期1030-1033,共4页
目的观察内外侧联合入路内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折的临床疗效。方法回顾性分析自2020-01—2023-09采用内外侧联合入路内固定治疗的21例Klammer Ⅱ、Ⅲ型后Pilon骨折,先取踝关节外侧入路充分显露腓骨骨折断端,用撑开器撑开... 目的观察内外侧联合入路内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折的临床疗效。方法回顾性分析自2020-01—2023-09采用内外侧联合入路内固定治疗的21例Klammer Ⅱ、Ⅲ型后Pilon骨折,先取踝关节外侧入路充分显露腓骨骨折断端,用撑开器撑开腓骨骨折断端,显露胫骨远端后外侧关节面;再取踝关节内侧入路依次切开至内侧骨折断端,再从腓骨骨折断端进入,内外侧同时清理并松解胫骨远端后侧骨性结构;关节面复位满意后,选择合适长度的空心钉从胫骨前方置入固定后外侧骨折块,再选择合适的解剖锁定钢板经外侧入路固定腓骨,选择合适长度的空心钉经内侧入路固定后内侧骨折块,Klammer Ⅲ型骨折患者需同时经内侧入路置入空心钉固定前内侧骨折块。结果21例均获得随访,随访时间13~25个月,平均18.7个月。所有患者未出现切口感染、骨折复位丢失、骨折不愈合及内固定松动等并发症。骨折均愈合良好,愈合时间为3~5个月,平均3.7个月。末次随访时踝与后足功能AOFAS评分为83~94分,平均88.9分;优11例,良10例。末次随访疼痛VAS评分为0~3分,平均1.2分。结论与后内入路、后外入路及二者联合入路相比,内外侧联合入路局部解剖简单,软组织剥离和损伤小,可减少术中体位变换,充分显露胫骨远端后侧关节面,提供清晰的手术视野,有利于骨折复位和内固定置入,可作为内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折的手术入路。 展开更多
关键词 KlammerⅡ、Ⅲ型后Pilon骨折 内外侧联合入路 内固定 空心钉 锁定钢板
原文传递
经皮三维空心钉与开放钢板固定跟骨骨折比较 被引量:1
10
作者 张洋 孔德海 +2 位作者 赵永杰 刘颖 孙广超 《中国矫形外科杂志》 北大核心 2025年第4期318-323,共6页
[目的]探讨经皮三维空心钉与开放钢板固定治疗Sanders Ⅱ型及Ⅲ型跟骨骨折的临床疗效。[方法]回顾性分析2019年12月—2021年12月本科手术治疗的99例Sanders Ⅱ型和Ⅲ型跟骨骨折患者。根据医患沟通结果,51例采用闭合复位埋头钉三维立体... [目的]探讨经皮三维空心钉与开放钢板固定治疗Sanders Ⅱ型及Ⅲ型跟骨骨折的临床疗效。[方法]回顾性分析2019年12月—2021年12月本科手术治疗的99例Sanders Ⅱ型和Ⅲ型跟骨骨折患者。根据医患沟通结果,51例采用闭合复位埋头钉三维立体髓内固定治疗(经皮组);48例采用切开复位钢板螺钉内固定治疗(开放组)。比较两组患者围手术期、随访和影像资料。[结果]经皮组手术时间[(50.2±1.8)min vs(87.6±1.8)min,P<0.001]、切口长度[(3.1±0.5)cm vs(14.3±0.4)cm,P<0.001]、术中出血量[(15.0±1.8)mL vs(164.9±1.8)mL,P<0.001]、住院时间[(4.0±0.2)d vs(9.9±0.2)d,P<0.001]均显著少于开放组,但经皮组术中透视次数[(17.1±1.9)次vs(4.9±1.8)次,P<0.001]显著多于开放组。经皮组术后下地行走时间和完全负重活动时间均显著早于开放组(P<0.05)。随时间推移,两组VAS、AOFAS评分和足内-外翻ROM均显著改善(P<0.05),术后3 d和末次随访时,经皮组VAS[(2.9±0.8)vs(5.8±1.1),P<0.001;(0.9±1.0)vs(2.0±1.0),P<0.001]、AOFAS踝-后足评分[(63.4±2.9)vs(60.6±2.6),P<0.001;(94.9±2.2)vs(91.1±2.5),P<0.001]和足内-外翻ROM[(15.4±0.6)°vs(11.7±0.7)°,P<0.001;(54.6±1.8)°vs(51.5±1.6)°,P<0.001]均显著优于开放组。影像方面,与术前相比,末次随访时两组Bohler角、Gissane角、软骨面塌陷、跟骨长度、跟骨宽度以及跟骨高度均显著改善(P<0.05),末次随访时,两组跟骨长度差异无统计学意义(P>0.05),但是,经皮组其他影像指标均显著优于开放组(P<0.05)。[结论]经皮三维空心钉髓内固定为髓内多维固定,根据跟骨应力分布设计置钉方向,更加符合跟骨的生物力学特征,可以有效固定术后跟骨的位置和正常形态,安全性更高。 展开更多
关键词 跟骨骨折 骨内固定 经皮空心螺钉 锁定钢板
原文传递
锁定钢板联合空心螺钉内固定治疗对踝关节骨折患者踝关节活动度及并发症的影响
11
作者 刘晓萌 《反射疗法与康复医学》 2025年第2期85-88,共4页
目的探讨锁定钢板联合空心螺钉内固定在踝关节骨折患者中的应用效果。方法回顾性分析2022年1月—2024年1月山东大学第三人民医院收治的100例踝关节骨折患者的病历资料,根据治疗方案的不同将其分为对照组和观察组,各50例。对照组采用传统... 目的探讨锁定钢板联合空心螺钉内固定在踝关节骨折患者中的应用效果。方法回顾性分析2022年1月—2024年1月山东大学第三人民医院收治的100例踝关节骨折患者的病历资料,根据治疗方案的不同将其分为对照组和观察组,各50例。对照组采用传统切开复位内固定术治疗,观察组采用锁定钢板联合空心螺钉内固定治疗。对比两组的愈合情况、踝关节活动度、踝关节功能及并发症发生情况。结果观察组下床时间、术后住院时间、骨折愈合时间均短于对照组,组间差异有统计学意义(P<0.05)。术后,两组内翻、外翻、背屈、跖屈活动度均大于术前,且观察组均大于对照组,差异有统计学意义(P<0.05);两组美国足踝外科协会踝-后足评分中各个维度评分均高于术前,且观察组均高于对照组,差异有统计学意义(P<0.05)。观察组并发症发生率为2.00%,低于对照组的16.00%,差异有统计学意义(P<0.05)。结论锁定钢板联合空心螺钉内固定治疗踝关节骨折患者可改善其踝关节活动度和踝关节功能,且并发症发生率较低,值得推广应用。 展开更多
关键词 踝关节骨折 锁定钢板 空心螺钉内固定 踝关节活动度 并发症
原文传递
颈前路减压融合ROI-C^(TM)自锁系统治疗退行性颈椎病的Meta分析 被引量:2
12
作者 周琰杰 曹春风 +5 位作者 张中卒 牛雄 王鑫 杨再海 周亮 李波 《中国组织工程研究》 CAS 北大核心 2025年第3期617-627,共11页
目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈... 目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。 展开更多
关键词 颈前路 减压融合 颈椎前路减压融合 颈椎病 ROI-C 自锁系统 Cage+钉板 META分析
暂未订购
装配式混凝土预制板桩在TAD工法中的应用
13
作者 齐金良 郑文韬 +2 位作者 常林越 周兆弟 俞峰 《建筑结构》 北大核心 2025年第24期144-150,共7页
为克服现浇地下连续墙存在的施工周期长、质量波动大、环境影响突出等问题,推动支护结构工业化发展,系统研究了装配式混凝土预制板桩的技术性能及其在TAD工法中的工程适用性。通过截面设计分析,量化了非配筋公母槽对桩体抗弯刚度的削弱... 为克服现浇地下连续墙存在的施工周期长、质量波动大、环境影响突出等问题,推动支护结构工业化发展,系统研究了装配式混凝土预制板桩的技术性能及其在TAD工法中的工程适用性。通过截面设计分析,量化了非配筋公母槽对桩体抗弯刚度的削弱程度约为11%;通过室内试验验证了装配式混凝土预制板桩板材及其接头具有良好的受弯与受剪性能,其抗裂弯矩、极限弯矩及抗剪承载力均满足或超过设计要求。结合上海浦东机场枢纽与杭州德寿宫遗址保护工程实践,验证了装配式混凝土预制板桩在TAD工法中的应用能有效控制基坑施工对周边环境的扰动,将深层土体位移控制在毫米级,并同时实现截水与挡土功能。研究表明,预制板桩应用于TAD工法适用于城市敏感区域的深基坑工程,为基坑工程绿色建造与节能增效提供了有效的技术途径。 展开更多
关键词 装配式混凝土预制板桩 截面设计 螺锁式连接 TAD工法 基坑支护
在线阅读 下载PDF
均布孔圆环工件透丝锁丝一体机开发
14
作者 夏伟民 吉晓民 刘叶 《机电工程技术》 2025年第5期158-164,共7页
针对均布孔圆环工件在加工过程中依靠人工手动完成喷塑后的丝孔剔透与螺钉锁附工艺费时费力、人工精度有限和一致性差等问题,提出一种为止动环喷塑后的丝孔剔透与螺钉锁附加工的自动化方案。结合企业生产需求,根据均布孔圆环工件丝孔剔... 针对均布孔圆环工件在加工过程中依靠人工手动完成喷塑后的丝孔剔透与螺钉锁附工艺费时费力、人工精度有限和一致性差等问题,提出一种为止动环喷塑后的丝孔剔透与螺钉锁附加工的自动化方案。结合企业生产需求,根据均布孔圆环工件丝孔剔透与螺钉锁附工艺需要的步骤和流程,结构上将机器划分为供料、分度、定位、丝孔剔透和螺丝锁付五大模块,采用人机界面(HMI)和PLC作为上、下位机设计控制系统,在WPL Soft软件编写控制程序实现了透丝锁丝一体机自动化过程,并在DOP Soft软件设计人机界面,实现加工动态可视化,更方便对透丝锁丝系统进行控制。生产运行数据表明,该设备能够精准高效的实现止动环的丝孔剔透和螺丝锁付操作,一个人操作一台设备的效率可相当于2.9名工人,带来1.9名工人的成本节省,证明了本文所设计的机械系统结构完善,编写的控制程序内容正确可靠,对提高企业自身的技术水平有重要的现实意义。 展开更多
关键词 自动化 螺丝锁付 丝孔剔透 PLC控制 人机界面
在线阅读 下载PDF
基于双机器人协作的车灯螺丝锁付自动化系统设计 被引量:1
15
作者 俞志明 潘明清 刘秋鹏 《中国照明电器》 2025年第9期62-66,共5页
针对车灯螺丝锁付装配精度差、工作效率低、人力成本高昂等问题,本文设计开发了一种基于双机器人协作的车灯螺丝自动锁付系统。该系统以PLC为显控一体机,通过EtherNet总线控制,实现了锁付系统和机器人之间的信息传输与控制,避免了复杂... 针对车灯螺丝锁付装配精度差、工作效率低、人力成本高昂等问题,本文设计开发了一种基于双机器人协作的车灯螺丝自动锁付系统。该系统以PLC为显控一体机,通过EtherNet总线控制,实现了锁付系统和机器人之间的信息传输与控制,避免了复杂的机器人运动轨迹规划。结合机器视觉引导技术进行的系统方案设计,解决了传统锁付中定位不准确的问题,实现了对复杂工件的高效、精准螺丝锁付。该系统提高了生产效率与装配精度,具备极高的应用价值与推广前景。 展开更多
关键词 双机器人协作 车灯 螺丝锁付 EtherNet总线 机器视觉
原文传递
螺锁式连接预应力混凝土异型桩的应用与实践 被引量:1
16
作者 冯翔 郁益波 《河北能源职业技术学院学报》 2025年第2期57-60,64,共5页
为提升桩基质量,头桥未来空间产业园项目采用螺锁式连接预应力混凝土异型方桩全新工艺。基于项目实践,深度探究此异型方桩的施工特性及关键技术要点,分别对运输与堆放、进场验收、沉桩施工、拼接作业以及验收等环节制定针对性的策略。... 为提升桩基质量,头桥未来空间产业园项目采用螺锁式连接预应力混凝土异型方桩全新工艺。基于项目实践,深度探究此异型方桩的施工特性及关键技术要点,分别对运输与堆放、进场验收、沉桩施工、拼接作业以及验收等环节制定针对性的策略。实践结果表明,此工艺有效提升了桩基质量,缩短了工期,为同类工程提供了关键技术与管理参考,有力推动了桩基施工工艺的创新发展。 展开更多
关键词 螺锁式连接预应力混凝土异型方桩 新工艺 应用与实践
在线阅读 下载PDF
锁定钢板尼斯结固定锁骨中段粉碎性骨折
17
作者 涂双强 姜瑞 +4 位作者 李中山 瞿琪 汪治宇 熊梦欣 马志平 《中国矫形外科杂志》 北大核心 2025年第17期1614-1618,共5页
[目的]评价锁定钢板结合尼斯结治疗锁骨中段粉碎性骨折的临床效果。[方法]回顾性分析本院2020年10月—2023年1月收治的67例锁骨中段粉碎性骨折患者的临床资料,根据医患沟通结果,33例采用尼斯结辅助锁定钢板固定(尼斯结组),34例运用拉力... [目的]评价锁定钢板结合尼斯结治疗锁骨中段粉碎性骨折的临床效果。[方法]回顾性分析本院2020年10月—2023年1月收治的67例锁骨中段粉碎性骨折患者的临床资料,根据医患沟通结果,33例采用尼斯结辅助锁定钢板固定(尼斯结组),34例运用拉力螺钉结合锁定钢板固定(拉力钉组)。比较两组临床及影像结果。[结果]所有患者均顺利完成手术,尼斯结组手术时间[(57.4±6.6)min vs(61.3±6.4)min,P=0.019]、切口长度[(5.1±0.6)cm vs(7.8±0.9)cm,P<0.001]、术中失血量[(66.9±12.7)mL vs(77.2±13.0)m L,P=0.020]均显著优于拉力钉组。随访时间均超过1年,与术后1个月相比,末次随访时,两组患者VAS评分、Constant-Murley评分、前屈上举ROM均显著改善(P<0.05),术后相应时间点,两组间上述指标的差异均无统计学意义(P>0.05)。影像方面,随时间推移,两组患者骨折对合及骨痂形成情况均显著改善(P<0.05),相应时间点,两组间上述影像指标的差异均无统计学意义(P>0.05)。[结论]锁定钢板尼斯结固定锁骨中段粉碎性骨折临床疗效可靠,在处理小游离骨块方面优势明显且拆除内固定创伤小。 展开更多
关键词 锁骨中段粉碎性骨折 尼斯结 拉力螺钉 锁定钢板
原文传递
关节镜辅助下锁定空心螺钉固定术对胫骨平台骨折患者膝关节功能和疼痛因子的影响 被引量:3
18
作者 李众 李强 《中国内镜杂志》 2025年第2期25-30,共6页
目的探讨关节镜辅助下锁定空心螺钉固定术对胫骨平台骨折患者膝关节功能和疼痛因子的影响。方法选取2021年6月-2023年6月该院收治的胫骨平台骨折患者113例,依据不同手术方法,将患者分为关节镜组(57例)和传统组(56例)。关节镜组采用关节... 目的探讨关节镜辅助下锁定空心螺钉固定术对胫骨平台骨折患者膝关节功能和疼痛因子的影响。方法选取2021年6月-2023年6月该院收治的胫骨平台骨折患者113例,依据不同手术方法,将患者分为关节镜组(57例)和传统组(56例)。关节镜组采用关节镜辅助下锁定空心螺钉固定术治疗,传统组采用切开复位内固定术治疗。比较两组患者手术情况、术后恢复情况、并发症发生率、术前和术后24h疼痛因子水平变化情况、术前和术后6个月膝关节功能,以及术后6个月膝关节活动度变化。结果关节镜组手术时间明显短于传统组,术中出血量明显少于传统组,差异均有统计学意义(P<0.05);两组患者术后24h血清5-羟色胺(5-HT)、P物质(SP)和前列腺素E2(PGE2)水平明显高于术前,但关节镜组明显低于传统组,差异均有统计学意义(P<0.05);关节镜组术后下床活动时间、住院时间、负重时间和骨折愈合时间明显短于传统组,差异均有统计学意义(P<0.05);两组患者术后6个月美国膝关节协会评分(KSS)临床评分、KSS功能评分和美国特种外科医院膝关节评分(HSS)比较,差异均无统计学意义(P>0.05);关节镜组术后6个月膝关节伸直度和屈曲度明显大于传统组,差异均有统计学意义(P<0.05);关节镜组术后切口感染明显少于传统组,差异有统计学意义(P<0.05)。结论关节镜辅助下锁定空心螺钉固定术治疗胫骨平台骨折,疗效较好,可明显改善患者膝关节功能,抑制疼痛因子释放,值得临床推广应用。 展开更多
关键词 关节镜 锁定空心螺钉固定术 胫骨平台骨折 膝关节功能 疼痛因子
暂未订购
带空心加压螺钉的股骨近端解剖锁定钢板内固定治疗股骨转子间骨折 被引量:1
19
作者 唐美洪 吴国兵 +1 位作者 何守斌 陈伟隆 《临床骨科杂志》 2025年第2期265-268,共4页
目的探讨带空心加压螺钉的股骨近端解剖锁定钢板内固定治疗股骨转子间骨折的疗效。方法采用带空心加压螺钉的股骨近端解剖锁定钢板内固定治疗43例股骨转子间骨折患者。记录手术情况、并发症发生情况、骨折愈合时间以及下地行走情况,采用... 目的探讨带空心加压螺钉的股骨近端解剖锁定钢板内固定治疗股骨转子间骨折的疗效。方法采用带空心加压螺钉的股骨近端解剖锁定钢板内固定治疗43例股骨转子间骨折患者。记录手术情况、并发症发生情况、骨折愈合时间以及下地行走情况,采用Harris评分评价髋关节功能。结果3例失访,2例在术后1年内死于其他系统疾病,38例随访12~24个月。手术时间45~90 min,术中出血量100~200 ml。1例肥胖患者切口出现皮下脂肪液化,3例发生膀胱刺激征。术后均未发生深静脉血栓形成、下肢反复肿胀以及疼痛症状,无钢板、螺钉断裂现象发生。骨折均愈合,时间8~12个月。术后1年,采用Harris评分评价髋关节功能:优35例,良2例,差1例,优良率为37/38;3例需扶拐行走,其余35例患者正常行走,无明显髋关节内、外翻畸形。结论带空心加压螺钉的股骨近端解剖锁定钢板内固定治疗股骨转子间骨折固定坚强,安全有效,疗效可靠。 展开更多
关键词 空心加压螺钉 股骨近端解剖锁定钢板 股骨转子间骨折
暂未订购
岸桥箱型梁装配辅助工装的标准化与系列化研究
20
作者 黄锦赛 《机械管理开发》 2025年第3期125-127,共3页
辅助工装是岸桥箱型梁装配作业中必不可少的工具,但目前岸桥箱型梁建设缺乏标准化和系列化的辅助工装。为此,提出岸桥箱型梁装配辅助工装的标准化与系列化研究。辅助工装标准结构为卡码结构、钢套衬垫以及螺旋锁紧结构三部分组成,根据... 辅助工装是岸桥箱型梁装配作业中必不可少的工具,但目前岸桥箱型梁建设缺乏标准化和系列化的辅助工装。为此,提出岸桥箱型梁装配辅助工装的标准化与系列化研究。辅助工装标准结构为卡码结构、钢套衬垫以及螺旋锁紧结构三部分组成,根据岸桥箱型梁腹板装配需求,对辅助工装各个结构尺寸标准化以及操作标准化;根据岸桥箱型梁装配需求,设计定位、夹紧、焊接、吊装、调整系列化的辅助工装。通过实际工程应用发现:应用辅助工装后,装配箱型梁的误差符合相关规范要求,说明辅助工装技术能够实现对箱型梁的精准装配。 展开更多
关键词 箱型梁 装配 辅助工装 卡码 钢套衬垫 螺旋锁紧
在线阅读 下载PDF
上一页 1 2 24 下一页 到第
使用帮助 返回顶部