期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evil-hunter: a novel web shell detection system based on scoring scheme 被引量:1
1
作者 张庭秀 程光 +1 位作者 郭晓军 潘吴斌 《Journal of Southeast University(English Edition)》 EI CAS 2014年第3期278-284,共7页
In order to detect web shells that hackers inject into web servers by exploiting system vulnerabilities or web page open sources, a novel web shell detection system based on the scoring scheme is proposed, named Evil-... In order to detect web shells that hackers inject into web servers by exploiting system vulnerabilities or web page open sources, a novel web shell detection system based on the scoring scheme is proposed, named Evil-hunter. First, a large set of malicious function samples normally used in web shells are collected from various sources on the Internet and security forums. Secondly, according to the danger level and the frequency of using these malicious functions in the web shells as well as in legal web applications, an assigning score strategy for each malicious sample is devised. Then, the appropriate score threshold value for each sample is obtained from the results of a statistical analysis. Finally, based on the threshold value, a simple algorithm is presented to identify files that contain web shells in web applications. The experimental results show that compared with other approaches, Evil-hunter can identify web shells more efficiently and accurately. 展开更多
关键词 web shell detection scoring scheme malicious code identification
在线阅读 下载PDF
Value of a new post-procedural intravascular ultrasound score in predicting target vessel revascularization after coronary drug-eluting stents implantation
2
作者 Kai XU Ya-ling HAN +5 位作者 Quan-min JING Shou-li WANG Ying-yan MA Xiao-zeng WANG Geng WANG Zu-lu WANG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2012年第8期624-630,共7页
Objective:There is no simple or feasible post-procedural intravascular ultrasound (IVUS) score to predict major adverse cardiac events (MACE) in patients undergoing drug-eluting stents (DES) implantation. The aim of t... Objective:There is no simple or feasible post-procedural intravascular ultrasound (IVUS) score to predict major adverse cardiac events (MACE) in patients undergoing drug-eluting stents (DES) implantation. The aim of this study is to validate a new IVUS score for predicting MACE. Methods:A total of 295 patients (with 322 lesions) were enrolled. IVUS score was calculated in each lesion based on five IVUS morphological characteristics:inflow/outflow disease, malapposition, underexpansion, tissue protrusion, and edge dissection (iMUTE score). We assigned two points to an underexpansion and one point for each presence of other factors. Patients were divided into low score (iMUTE score<2, n=137) and high score (iMUTE score≥2, n=158) groups. Results:At one year follow-up, a trend was seen in favor of the low iMUTE score group in MACE (3.65% vs. 10.10%; P=0.052), and there was more target vessel revascularization (TVR) in the high iMUTE score group compared with low score group (6.96% vs. 1.46%; P=0.044). Low iMUTE score was an independent predictor of freedom from TVR at one year (adjusted hazard ratio (HR) 0.5, 95% confidence interval (CI) 0.1-0.8; P=0.02). Conclusions:Post-procedural IVUS iMUTE scoring was simple and feasible in clinical practice, and can provide independent prognostic value for TVR in patients undergoing DES implantation. 展开更多
关键词 Intravascular ultrasound Drug eluting stents scoring schemes percutaneous coronary intervention
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部