期刊文献+
共找到99,286篇文章
< 1 2 250 >
每页显示 20 50 100
Statistics and Development Analysis of Urban Rail Transit in China by the End of 2025
1
作者 WANG Fuwen LIANG Shuaiwen FENG Aijun 《隧道建设(中英文)》 北大核心 2026年第2期437-444,I0005-I0012,共16页
First,statistics on the operational lines and mileage of urban rail transit in China are conducted.The results show that,as of Dec.31,2025,there were 60 cities with urban rail transit in operation nationwide,with a to... First,statistics on the operational lines and mileage of urban rail transit in China are conducted.The results show that,as of Dec.31,2025,there were 60 cities with urban rail transit in operation nationwide,with a total operational mileage of approximately 12837.8 km(excluding the electronic guideway rubber-tired system,there were 57 cities,with a total operational mileage of 12651.6 km).The metro system dominates,while low-capacity systems exhibit a multi-modal development pattern.Subsequently,the characteristics of China′s urban rail transit industry development are analyzed,indicating that:(1)It should closely align with the theme of urban intensive development,promote quality improvement and efficiency enhancement of existing lines,and focus on the supporting role of initial passenger flow for new line construction,multi-network integration,and economic and financial sustainability.(2)Significant innovative achievements have been made in safety resilience,green and low-carbon development,intelligent construction,and digital transformation.Finally,development recommendations for the"15th Five-Year Plan"period are proposed:promoting cost reduction and efficiency improvement in the rail transit industry,enhancing the operational efficiency of existing networks,continuously exploring railway services for urban commuting,strengthening external exchanges,and driving the"going global"strategy of the urban rail transit industry. 展开更多
关键词 rail transit operational lines data statistics development analysis
在线阅读 下载PDF
Instantaneous desulfurization of molten steel with varied aluminum and silicon by CaO-Al_(2)O_(3) particles:In situ observation using confocal scanning laser microscopy
2
作者 Chunjie She Hejun Zhang +2 位作者 Yanhui Zhang Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2026年第2期545-554,共10页
Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfur... Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfurization were analyzed.When the total aluminum content in the steel increased from 6 to 1100 ppm,the CaS content in CaO–Al_(2)O_(3) particles increased from 2.1wt%to 84.84wt%after the reaction for 90 s.Furthermore,when the silicon content in the steel increased from 0.01wt%to 2.20wt%,the CaS content in CaO–Al_(2)O_(3) particles increased from 1.53wt%to 79.01wt%after the reaction for 90 s.This indicates that the increase in the aluminum and silicon contents of the steel promoted the desulfurization of CaO–Al_(2)O_(3) particles.A kinetic model was established to predict the CaO–Al_(2)O_(3) particles composition,and the diffusion coefficient of sulfur in CaO–Al_(2)O_(3) particles was 9.375×10^(−10)m^(2)·s^(−1) at 1600℃,which provided a new method for the calculation of diffusion coefficient. 展开更多
关键词 DESULFURIZATION high-temperature confocal scanning laser microscopy steel DESULFURIZER kinetic model ALUMINUM SILICON
在线阅读 下载PDF
Research on the Application of Digital Intraoral Scanning Impression Technique in Oral Implant Restoration for Periodontitis Patients and Its Impact on VAS Scores
3
作者 Fei Chen Jingke Liu 《Journal of Clinical and Nursing Research》 2026年第1期61-67,共7页
Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)score... Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)scores.Methods:A total of 80 periodontitis patients who received implant restoration in our hospital from May 2023 to May 2025 were selected as research subjects.They were randomly divided into an observation group and a control group using a random number table method,with 40 cases in each group.The observation group used the digital intraoral scanning impression technique to obtain impressions,while the control group used the traditional silicone rubber impression technique.The impression-taking time,the number of prostheses try-ins,implant survival rate,periodontal health indicators(probing depth,gingival index,bleeding index),and VAS scores(pain during treatment and comfort after restoration)were compared between the two groups.Results:The observation group was superior to the control group in terms of impression-taking time,the number of prostheses try-ins,and implant survival rate(p<0.05).Six months after restoration,the improvement in periodontal health indicators in the observation group was significantly better than that in the control group(p<0.05).In addition,the pain VAS score of the observation group during treatment was lower than that of the control group,and the comfort VAS score after restoration was higher than that of the control group(p<0.05).Conclusion:Digital intraoral scanning impression technology can effectively enhance the efficiency and success rate of implant restoration in periodontitis patients,improve periodontal health,alleviate patients’discomfort during treatment,and increase post-restoration comfort,demonstrating high clinical application value. 展开更多
关键词 Digital intraoral scanning impression technology PERIODONTITIS Oral implant restoration Visual analog scale Implant survival rate
暂未订购
Does prospective permutation scan statistics work well with cutaneous leishmaniais as a high-frequency or malaria as a low-frequency infection in Fars province, Iran?
4
作者 Abbas Rezaianzadeh Marjan Zare +3 位作者 Hamidreza Tabatabaee Mohsen Ali-Akbarpour Hossain Faramarzi Mostafa Ebrahimi 《Asian Pacific Journal of Tropical Biomedicine》 SCIE CAS 2018年第10期478-484,共7页
Objective: To determine whether permutation scan statistics was more efficient in finding prospective spatial-temporal outbreaks for cutaneous leishmaniasis(CL) or for malaria in Fars province, Iran in 2016. Methods: ... Objective: To determine whether permutation scan statistics was more efficient in finding prospective spatial-temporal outbreaks for cutaneous leishmaniasis(CL) or for malaria in Fars province, Iran in 2016. Methods: Using time-series data including 29 177 CL cases recorded during 2010-2015 and 357 malaria cases recorded during 2010-2015, CL and malaria cases were predicted in 2016. Predicted cases were used to verify if they followed uniform distribution over time and space using space-time analysis. To testify the uniformity of distributions, permutation scan statistics was applied prospectively to detect statistically significant and non-significant outbreaks. Finally, the findings were compared to determine whether permutation scan statistics worked better for CL or for malaria in the area. Prospective permutation scan modeling was performed using SatScan software. Results: A total of 5 359 CL and 23 malaria cases were predicted in 2016 using time-series models. Applied timeseries models were well-fitted regarding auto correlation function, partial auto correlation function sample/model, and residual analysis criteria(Pv was set to 0.1). The results indicated two significant prospective spatial-temporal outbreaks for CL(P<0.5) including Most Likely Clusters, and one non-significant outbreak for malaria(P>0.5) in the area. Conclusions: Both CL and malaria follow a space-time trend in the area, but prospective permutation scan modeling works better for detecting CL spatial-temporal outbreaks. It is not far away from expectation since clusters are defined as accumulation of cases in specified times and places. Although this method seems to work better with finding the outbreaks of a high-frequency disease; i.e., CL, it is able to find non-significant outbreaks. This is clinically important for both high-and low-frequency infections; i.e., CL and malaria. 展开更多
关键词 CUTANEOUS leishmaniais MALARIA PROSPECTIVE PERMUTATION scan statistics Fars PROVINCE Iran
暂未订购
Program Construction Method for Sequential Statistics Class Algorithm Based on Bidirectional Scanning Induction
5
作者 ZUO Zhengkang WANG Yuekun +4 位作者 LIANG Zanyang SU Wei HUANG Qing WANG Yuan WANG Changjing 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2023年第6期483-492,共10页
The program construction process is based on rigorous mathematical reasoning,which leads to a fully correct algorithmic program via step-by-step refinement of the program specifications.The existing program constructi... The program construction process is based on rigorous mathematical reasoning,which leads to a fully correct algorithmic program via step-by-step refinement of the program specifications.The existing program construction methods'refinement process is partly based on individual subjective speculation and analysis,which lacks a precise guidance method.Meanwhile,efficiency factors have usually been ignored in the construction process,and most of the constructed abstract programs cannot be run directly by machines.In order to solve these problems,a novel program construction method for the sequence statistical class algorithms based on bidirectional scan induction is proposed in this paper.The method takes into account the efficiency factor and thus improves the Morgan's refinement calculus.Furthermore,this paper validates the method's feasibility using an efficiency-sensitive sequential statistics class algorithm as a program construction example.The method proposed in this paper realizes the correctness construction process from program specifications to efficient executable programs. 展开更多
关键词 program construction bidirectional scanning induction sequential statistics Morgan's refinement calculus
原文传递
In-situ observation of nonmetallic inclusions in steel using confocal scanning laser microscopy:A review 被引量:4
6
作者 Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2025年第5期975-991,共17页
The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are revi... The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are reviewed and summarized,particularly the col-lision of various inclusions,dissolution of inclusions in liquid slag,and reactions between inclusions and steel.Solid inclusions exhibited a high collision tendency,whereas pure liquid inclusions exhibited minimal collisions because of the small attraction force induced by their<90°contact angle with molten steel.The collision of complex inclusions in molten steel was not included in the scope of this study and should be evaluated in future studies.Higher CaO/Al_(2)O_(3)and CaO/SiO_(2)ratios in liquid slag promoted the dissolution of Al_(2)O_(3)-based in-clusions.The formation of solid phases in the slag should be prevented to improve dissolution of inclusions.To accurately simulate the dissolution of inclusions in liquid slag,in-situ observation of the dissolution of inclusions at the steel-slag interface is necessary.Using a combination of CSLM and scanning electron microscopy-energy dispersive spectroscopy,the composition and morphological evolution of the inclusions during their modification by the dissolved elements in steel were observed and analyzed.Although the in-situ observa-tion of MnS and TiN precipitations has been widely studied,the in-situ observation of the evolution of oxide inclusions in steel during so-lidification and heating processes has rarely been reported.The effects of temperature,heating and cooling rates,and inclusion character-istics on the formation of acicular ferrites(AFs)have been widely studied.At a cooling rate of 3-5 K/s,the order of AF growth rate in-duced by different inclusions,as reported in literature,is Ti-O<Ti-Ca-Zr-Al-O<Mg-O<Ti-Zr-Al-O<Mn-Ti-Al-O<Ti-Al-O<Zr-Ti-Al-O.Further comprehensive experiments are required to investigate the quantitative relationship between the formation of AFs and inclusions. 展开更多
关键词 INCLUSION STEEL in-situ observation confocal scanning laser microscopy
在线阅读 下载PDF
基于深度学习的大规模室外场景Scan2BIM研究综述 被引量:1
7
作者 莫洋 王晶 +4 位作者 蒋海峰 张业星 曲柄宇 王雷 冯卓航 《计算机辅助设计与图形学学报》 北大核心 2025年第6期905-931,共27页
当前,大规模室外基础设施的数字化需求持续扩大,基于深度学习的自动扫描到建筑信息模型(scanning to building information modeling, Scan2BIM)通过卓越的特征学习能力和自动化流程显著提升了建模精度和构建速度,在结构复杂的室外场景... 当前,大规模室外基础设施的数字化需求持续扩大,基于深度学习的自动扫描到建筑信息模型(scanning to building information modeling, Scan2BIM)通过卓越的特征学习能力和自动化流程显著提升了建模精度和构建速度,在结构复杂的室外场景重建中发挥了关键作用.文中介绍了Scan2BIM的4大核心模块及其相关研究进展.其中,针对3D点云获取模块,从采集设备与采集来源2个维度概括了3D点云数据采集的技术发展,并着重梳理了代表性3D点云数据集;根据学习方式的不同,将大规模点云对齐算法划分为基于优化和深度学习2大类,并从精准度、计算效率、鲁棒性等多维度对比分析了相关工作;在点云分割模块中,分别对点云全景分割和点云实例分割算法通过统一的评估指标进行了整理归纳;对于BIM自动化建模,简述了BIM核心互操作标准体系,并分类总结了多种几何实体建模与关系建模算法.最后,通过深入分析和前瞻性探讨,指出了现阶段大规模室外场景建模的高效性、精准性、泛化性与统一性的无法有效结合的问题;未来将重点围绕多源数据融合建模、精度与鲁棒性协同优化、端到端Scan2BIM通用框架构建以及大模型应用与探索等方向展开. 展开更多
关键词 scan2BIM 深度学习 3D点云 逆向建模 大规模室外场景
在线阅读 下载PDF
In-situ observation and analysis of high temperature behavior of carbides in GCr15 bearing steel by confocal laser scanning microscopy 被引量:2
8
作者 Jun Ren Yue Teng +4 位作者 Xiang Liu Xi Xu Hui-gai Li Ke Han Qi-jie Zhai 《Journal of Iron and Steel Research International》 2025年第2期409-417,共9页
The high-temperature dissolution behavior of primary carbides in samples taken from GCr15 continuous-casting bloom was observed in-situ by confocal laser scanning microscopy.Equations were fitted to the dissolution ki... The high-temperature dissolution behavior of primary carbides in samples taken from GCr15 continuous-casting bloom was observed in-situ by confocal laser scanning microscopy.Equations were fitted to the dissolution kinetics of primary carbides during either heating or soaking.Dissolution of carbides proceeded in three stages(fast→slow→faster)as either temperature or holding time was increased.During the heating process and during the first and third stages of the soaking process,the original size of the carbides determined the steepness of the slope,but during the middle(“slow”)stage of the soaking process,the slope remained zero.The initial size of the carbides varied greatly,but their final dissolution temperature fell within the narrow range of 1210-1235℃,and the holding time remained within 50 min.Fractal analysis was used to study the morphological characteristics of small and medium-sized carbides during the dissolution process.According to changes in the fractal dimension before and after soaking,the carbides tended to evolve towards a more regular morphology. 展开更多
关键词 Bearing steel High-temperature confocal laser scanning microscope In-situ observation Primary carbide Fractal analysis
原文传递
电子鼻咽喉镜中I-scan各模式与白光模式的应用比较 被引量:2
9
作者 倪凌达 唐旭兰 +2 位作者 孟丽丽 周慧群 苏开明 《山东大学耳鼻喉眼学报》 2025年第3期19-25,共7页
目的探讨日本宾得(Pentax)所产电子鼻咽喉镜的I-scan功能中各项模式与白光模式在鼻咽喉科疾病图像显示中的适用性。方法回顾性分析96例鼻咽喉科疾病患者的图像资料,对其在6种I-scan模式与白光(WL)模式下拍摄的图片进行互相比较。结果I-s... 目的探讨日本宾得(Pentax)所产电子鼻咽喉镜的I-scan功能中各项模式与白光模式在鼻咽喉科疾病图像显示中的适用性。方法回顾性分析96例鼻咽喉科疾病患者的图像资料,对其在6种I-scan模式与白光(WL)模式下拍摄的图片进行互相比较。结果I-scan功能中各模式与白光模式的摄片效果有显著差异,p、b、e、g、c模式下的图像在细节显示、血管突出方面优于白光模式,以g、c模式优点更为显著,v模式则表现差于白光模式。结论在鼻咽喉科疾病的图片资料采摄中,I-scan各模式有效补充白光模式的短板,各模式互补利用,临床诊断效率提高,值得推广应用。 展开更多
关键词 电子鼻咽喉镜 I-scan功能 窄带成像技术 黏膜微腺管 白光图像
原文传递
A centroid measurement method based on 3D scanning 被引量:1
10
作者 HE Xin LI Zhen 《Journal of Measurement Science and Instrumentation》 2025年第2期186-194,共9页
The centroid coordinate serves as a critical control parameter in motion systems,including aircraft,missiles,rockets,and drones,directly influencing their motion dynamics and control performance.Traditional methods fo... The centroid coordinate serves as a critical control parameter in motion systems,including aircraft,missiles,rockets,and drones,directly influencing their motion dynamics and control performance.Traditional methods for centroid measurement often necessitate custom equipment and specialized positioning devices,leading to high costs and limited accuracy.Here,we present a centroid measurement method that integrates 3D scanning technology,enabling accurate measurement of centroid across various types of objects without the need for specialized positioning fixtures.A theoretical framework for centroid measurement was established,which combined the principle of the multi-point weighing method with 3D scanning technology.The measurement accuracy was evaluated using a designed standard component.Experimental results demonstrate that the discrepancies between the theoretical and the measured centroid of a standard component with various materials and complex shapes in the X,Y,and Z directions are 0.003 mm,0.009 mm,and 0.105 mm,respectively,yielding a spatial deviation of 0.106 mm.Qualitative verification was conducted through experimental validation of three distinct types.They confirmed the reliability of the proposed method,which allowed for accurate centroid measurements of various products without requiring positioning fixtures.This advancement significantly broadened the applicability and scope of centroid measurement devices,offering new theoretical insights and methodologies for the measurement of complex parts and systems. 展开更多
关键词 centroid measurement mass characteristic parameter 3D scanning 3D point cloud data no specialized positioning fixtures multi-point weighing method
在线阅读 下载PDF
An investigation of single-phased metallic solidification process using high-temperature confocal laser scanning microscope combined with differential scanning colorimetry
11
作者 Xing-zhi Zhou De-yong Wang +6 位作者 Tian-peng Qu Dong Hou Shao-yan Hu Jun Tian Xiang-long Li Lei Fan Zhi-xiao Zhang 《Journal of Iron and Steel Research International》 2025年第2期437-451,共15页
To investigate the nucleation behavior during the single-phased metallic solidification process,the commercial ultrapure ferritic stainless steels with no(Initial steel)and various melt treatments(R1,MR1,Y2,MY1,and M1... To investigate the nucleation behavior during the single-phased metallic solidification process,the commercial ultrapure ferritic stainless steels with no(Initial steel)and various melt treatments(R1,MR1,Y2,MY1,and M1 steels)were used to carry out the differential scanning colorimetry(DSC)and high-temperature confocal laser scanning microscope(HT-CLSM)experiments.Based on the results of DSC experiments,the equilibrium solidification process as well as the relationship among the critical undercooling degree(△T_(c)^(DSC)),latent heat of fusion/crystallization(△H_(f)/△H_(c)),equiaxed grain ratio(ER),and average grain size(△_(ave)^(ingot))was revealed.ER is increased with the decreasing△T_(c)^(DSC)and increasing△H_(f)/△H_(c);however,△_(ave)^(ingot)is decreased with them.Referring to the results of HT-CLSM experiments,the average sizes of micro-/macrostructures(d_(ave)/D_(ave)/)are decreased with the increasing cooling rate,as well as the difference between and apparent critical undercooling degree(△T_(c)^(CLSM))was revealed.The heterogeneous nucleation of the crystal nuclei occurs only if△T_(c)^(CLSM)>△T_(c)^(DSC).Combining with the interfacial wetting-lattice mismatch heterogeneous nucleation model,the dynamic mechanism of the metallic solidification was revealed.The as-cast grains of the melt-treated samples were obviously refined,owing to the much higher actual heterogeneous nucleation rates(I_(heter.,i))obtained through melt treatments,and the heterogeneous nucleation rates(I_(heter.,ij))for all samples are increased with the cooling rates,firmly confirming that the as-cast grains of each sample could be refined by the increasing cooling rates. 展开更多
关键词 NUCLEATION Metallic solidification process Differential scanning colorimetry High-temperature confocal laser scanning microscope Interfacial wetting-lattice mismatch heterogeneous nucleation model
原文传递
Circular interleaving scan OCT enhances motion-contrast for 360 deg large-field iris angiography
12
作者 Gongpu Lan Delie Kong +7 位作者 Qun Shi Zhipeng Wei Jingjiang Xu Yanping Huang Jia Qin Lin An Michael D.Twa Xunbin Wei 《Advanced Photonics Nexus》 2025年第5期86-98,共13页
In vivo imaging of human iris vasculature remains a persistent challenge,limiting our understanding of its relationship with ocular disease pathogenesis.Conventional raster scan optical coherence tomography angiograph... In vivo imaging of human iris vasculature remains a persistent challenge,limiting our understanding of its relationship with ocular disease pathogenesis.Conventional raster scan optical coherence tomography angiography(OCTA)suffers from angular-dependent contrast(including blind spots),limited field of view,and prolonged imaging time—challenges that restrict its clinical utility.We introduce a circular interleaving scan OCTA method that overcomes these barriers by enabling 360 deg high-contrast iris angiography with consistent spatiotemporal sampling and optimized motion contrast.The circular scan design enables directionoptimized sampling:we configured circumferential sampling density to approximately twice the radial density,enhancing detection of radially oriented iris vasculature.A Cartesian–polar coordinate transformation was implemented for eye-motion compensation,vessel realignment,and vasculature reconstruction.Compared with raster scan OCTA,our circular scan protocol demonstrates 1.55×higher efficiency in iris vascular imaging,featuring a superior duty cycle(99.95%versus 82.00%)and eliminating redundant data acquisition from rectangular field corners(27.3%of the circular area).This method improves vessel density measurement by 39.0%and vessel count quantification by 25.2%relative to raster scans.By eliminating angular-dependent blind spots,our method significantly enhances vascular quantification reliability,paving the way to a better understanding of ocular diseases and holding promising potential for future clinical applications. 展开更多
关键词 optical coherence tomography angiography iris vascular imaging circular scan spatiotemporal interleaving scan Cartesian–polar coordinate transformation
在线阅读 下载PDF
Robust,High-Magnetic-Field-Resistance Design of Scanning Head Equipped with 12 T Superconductor Magnet and sub-Kelvin He-3 Cryostat
13
作者 Junwei Liu Kesen Zhao +5 位作者 Aile Wang Min Zhang Jihao Wang Yubin Hou Wenjie Meng Qingyou Lu 《Chinese Journal of Chemical Physics》 2025年第6期855-864,I0238,I0239,共12页
We have constructed the robust and highfield-stability scanning tunneling microscopy(STM)system which is equipped with a 12 Tsuperconductor magnet and the He-3 cryostat,obtaining the high-quality data of graphite whic... We have constructed the robust and highfield-stability scanning tunneling microscopy(STM)system which is equipped with a 12 Tsuperconductor magnet and the He-3 cryostat,obtaining the high-quality data of graphite which can be clearly characterized up to the 12-T high magnetic field and bulk 2H-NbSe2 whose vortex structure and surface defects can be clearly visualized by the scanning and dI/dV mapping.The pivotal factor of our superior data stems from the sapphire frame and its unique structure,which ensure an exceptional performance for the noise,which has the current spectral density low to 2×10^(-13)A√Hz at the low frequency with the cut-off frequency of 250 Hz and the engaging status,of vibration,promising to the robust platform for the investigation of the surface of materials.The low drifting rate from the image of graphite is v_(x)=-8:79×10^(-7)nm/s and v_(y)=-3.26×10^(-6)nm/s at 12 T and 0.3 K.Besides,equipped with the high-capacity He-3 cryostat(with 15 normal temperature and pressure liter He-3 gas),the system,which has the base temperature for 0.28 K,can operate at the low temperature for more than 72 h,ensuring the enduring research at the sub-Kelvin temperature for the dI/dV mapping and large-scale scanning.When the magnetic field is applied up to 12 T,the STM system also obtains the excellent-clarity and undistorted images of graphite,which proves the outstanding performance of the system at the high-field researches. 展开更多
关键词 sub-Kelvin High magnetic field Low noise High-stability scanning tunneling microscopy
在线阅读 下载PDF
基于MATLAB与PhotoScan的相机检校方法对比研究
14
作者 周健 罗玉恒 苟彦梅 《信息与电脑》 2025年第9期184-186,共3页
文章基于单站点自校准方法,利用MATLAB和Photo Scan软件分别进行相机内参数及畸变系数的标定,对比分析不同模型与软件的校准效果。实验采用10×7黑白校准板,拍摄69张多角度覆盖影像,通过设置不同畸变参数和切向畸变参数,计算重投影... 文章基于单站点自校准方法,利用MATLAB和Photo Scan软件分别进行相机内参数及畸变系数的标定,对比分析不同模型与软件的校准效果。实验采用10×7黑白校准板,拍摄69张多角度覆盖影像,通过设置不同畸变参数和切向畸变参数,计算重投影误差与焦距估计偏差。结果表明,不同校准方法和模型对焦距及畸变参数的计算存在一定差异,选择合适的校准参数可有效提高测量精度。 展开更多
关键词 MATLAB Photo scan 相机检校方法
在线阅读 下载PDF
Hemoglobin oxygen saturation in myopic eyes:a scanning laser ophthalmoscope study
15
作者 Zi-Xuan Xiao Kun-Liang Qiu +3 位作者 Hui Zhou De-Zhi Zheng Tsz Kin Ng Geng Wang 《International Journal of Ophthalmology(English edition)》 2025年第11期2130-2136,共7页
AIM:To evaluate retinal hemoglobin oxygen saturation in myopic eyes by scanning laser ophthalmoscope(SLO)and to assess its correlations with different severity of myopia.METHODS:Sixty-one eyes from 61 patients were in... AIM:To evaluate retinal hemoglobin oxygen saturation in myopic eyes by scanning laser ophthalmoscope(SLO)and to assess its correlations with different severity of myopia.METHODS:Sixty-one eyes from 61 patients were included and subdivided into three groups according to their refractive errors:high myopia group[20 eyes,spherical equivalent(SE)≤-6 D];low and moderate myopia(22 eyes,-6.0<SE≤-0.5 D);normal(19 eyes,-0.5<SE<+0.5 D).All subjects underwent SLO imaging with dual lasers(532 nm and 633 nm).The oxygen saturations of hemoglobin in arteries(SO_(2)A)and veins(SO_(2)V),and their differences(SO_(2)AV)were estimated from the optical densities of the vessels on the images at the two wavelengths.Pearson’s or Spearman’s rank correlation coefficient were calculated to assess the correlation between retinal hemoglobin oxygen saturation and refractive error/axial length(AL).RESULTS:For the retinal oxygen saturation,the SO_(2)V in high myopia group(73.21%±21.42%)was significantly higher than that in normal group(55.81%±21.69%)and low and moderate myopia group(56.88%±13.83%,P<0.05).The SE was significantly correlated with SO_(2)A(r=-0.30)and SO_(2)V(r=-0.36;P<0.05),and AL was also significantly correlated with SO_(2)A(r=0.27)and SO_(2)V(r=0.30;P<0.05).No significant correlations were found between SO_(2)AV and SE and AL(P>0.05).CONCLUSION:SO_(2)A and SO_(2)V increased in more myopic eye based on SLO measurements.Further studies are warranted to investigate the changes of retinal hemoglobin oxygen saturation in myopia with different methods. 展开更多
关键词 MYOPIA RETINA hemoglobin oxygen saturation scanning laser ophthalmoscope
原文传递
Molecular conformational effects on co-assembly systems of low-symmetric carboxylic acids investigated by scanning tunneling microscopy
16
作者 Yutong Xiong Ting Meng +3 位作者 Wendi Luo Bin Tu Shuai Wang Qingdao Zeng 《Chinese Journal of Structural Chemistry》 2025年第2期57-61,共5页
The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-d... The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-dicarboxylic acid(BCBDA))containing naphthalene rings on graphite surfaces have been investigated using scanning tunneling microscopy(STM).The transformation of nanostructures induced by the second components(EDA and PEBP-C4)have been also examined.Both CTTA and BCBDA molecules self-assemble at the 1-heptanoic acid(HA)/HOPG interface,forming porous network structures.The dimer represents the most elementary building unit due to the formation of double hydrogen bonds.Moreover,the flipping of naphthalene ring results in the isomerization of BCBDA molecule.The introduction of carboxylic acid derivative EDA disrupts the dimer,which subsequently undergoes a structural conformation to form a novel porous structure.Furthermore,upon the addition of pyridine derivative PEBP-C4,N–H⋯O hydrogen bonds are the dominant forces driving the three coassembled structures.We have also conducted density functional theory(DFT)calculations to determine the molecular conformation and analyze the mechanisms underlying the formation of nanostructures. 展开更多
关键词 Co-assembly CONFORMATION Hydrogen bonds scanning tunneling microscopy DFT calculations
原文传递
Manipulation of vortex array via a magnetism-tunable spin-polarized scanning tunnelling microscopy
17
作者 Bing Xia Hong-Yuan Chen +13 位作者 Jian Zheng Bo Yang Jie Cai Yi Zhang Yi Yang Hao Yang Dan-Dan Guan Xiao-Xue Liu Liang Liu Yao-Yi Li Shi-Yong Wang Can-Hua Liu Hao Zheng Jin-Feng Jia 《Chinese Physics B》 2025年第3期190-194,共5页
Manipulating and braiding Majorana zero modes(MZM)are a critical step toward realizing topological quantum computing.The primary challenge is controlling the vortex,which hosts the MZM,within a superconducting film in... Manipulating and braiding Majorana zero modes(MZM)are a critical step toward realizing topological quantum computing.The primary challenge is controlling the vortex,which hosts the MZM,within a superconducting film in a spatially precise manner.To address this,we developed a magnetic force-based vortex control technology using the STM system with a self-designed four-electrode piezo-scanner tube and investigated vortex manipulation on the NbSe_(2) superconducting film.We employed ferromagnetic tips to control the movement of vortex array induced by the tip's remanent magnetism.A magnetic core solenoid device was integrated into the STM system and a strong magnetic tip demagnetization technique was developed,providing a viable technical solution for further enabling single vortex manipulation. 展开更多
关键词 vortex manipulation scanning tunneling microscope magnetic tip demagnetization technique
原文传递
Optical manipulation of neuronal mitochondria using scanning optical tweezers
18
作者 Zhiyong Gong Tianli Wu +4 位作者 Xixi Chen Ping Wang Jinghui Guo Yuchao Li Baojun Li 《Journal of Innovative Optical Health Sciences》 2025年第4期205-214,共10页
Mitochondria play a crucial role in the physiological functions and energy metabolism of neurons,which can help in the understanding of complex biochemical reactions associated with various neurodegenerative diseases.... Mitochondria play a crucial role in the physiological functions and energy metabolism of neurons,which can help in the understanding of complex biochemical reactions associated with various neurodegenerative diseases.Neurons,being highly differentiated terminal cells,require a greater number of mitochondria than ordinary cells to generate significant amounts of ATP,which is necessary for the growth of differentiated neuronal structures like axons and dendrites and the transmission of electrical signals along neuronal axons.Advancements in imaging technology,electrophysiology,and fluorescence targeting labeling have facilitated the study of mitochondrial movements in neurons and axons.However,disordered mitochondrial movements can hinder their analysis and characterization.Thus,it becomes necessary to artificially control their transport.Here,we demonstrate the utilization of scanning optical tweezers(SOTs)on the stable trapping and precise transport of soma or axon of neurons and enable.The presented method provides an optical approach to the control of mitochondria or other organelles in complex and variable biological environment. 展开更多
关键词 scanning optical tweezers neuronal mitochondrial transport optical trapping
原文传递
Optimizing Contrast-Enhanced Magnetic Resonance Neurography of the Brachial Plexus With Delayed Scanning
19
作者 Jun Xu Xiaoli Hu +7 位作者 Xiaoyun Su Shen Gui Ziqiao Lei Xiaoming Liu Xiangzhi Zhou Lixia Wang Wenjun Wu Xiangchuang Kong 《iRADIOLOGY》 2025年第2期168-175,共8页
Background:Contrast-enhanced magnetic resonance neurography(ceMRN)can enhance brachial plexus visualization and quality of imaging.However,the interval between contrast injection and scanning that provides the highest... Background:Contrast-enhanced magnetic resonance neurography(ceMRN)can enhance brachial plexus visualization and quality of imaging.However,the interval between contrast injection and scanning that provides the highest-quality images is not known.Methods:Fifteen patients underwent brachial plexus imaging using the 3D T2-NerveView sequence with a scanning duration of 5 min.A consecutive six-phase scan was initiated immediately at the start of contrast agent injection.Subsequently,all patients'images were classified into six groups according to the phases:group A(phase 1,delay 0 min),group B(phase 2,delay 5 min),group C(phase 3,delay 10 min),group D(phase 4,delay 15 min),group E(phase 5,delay 20 min),and group F(phase 6,delay 25 min).The image quality in each group was assessed based on nerve signal(signalnerve),muscle signal(signalmuscle),lymph node signal(signallymph node),background noise(BN),signal-to-noise ratio(SNR),contrast-to-noise ratio(CNR),and subjective score.Results:Signalnerve,signalmuscle,BN,and SNR did not significantly differ among the six groups(p>0.05).However,significant differences(p<0.05)were observed in signallymph node(F=16.067),CNR(F=9.495),and subjective score(χ^(2)=23.586).As the scanning delay increased,signallymph node intensity gradually increased whereas the CNR gradually decreased.The subjective score was significantly higher in groups B(4.830.24),C(4.900.21),D(4.870.30),E(4.830.31),and F(4.830.31)than in group A(4.470.30).Conclusion:We recommend performing brachial plexus ceMRN 5 min after contrast injection.With this delay,the brachial plexus can be visualized optimally with minimal interference from background signals. 展开更多
关键词 brachial plexus compressed sensing delayed scanning image quality magnetic resonance neurography
暂未订购
基于Scan-to-BIM的现有农村建筑改造的零碳建筑数字孪生评价研究
20
作者 赵亮 王海宁 +3 位作者 侯佳松 崔骜然 张雪吉 李庆龄 《西安建筑科技大学学报(自然科学版)》 北大核心 2025年第2期280-287,共8页
全球变暖、碳排放剧增以及对石化能源过度依赖等问题正日益引起各行业的关注.占总能耗约1/3的建筑行业更需要有效的管理和使用可再生能源.本研究提出一个利用激光扫描技术识别和评估现有农村建筑实现零碳建筑的框架.该框架将点云数据转... 全球变暖、碳排放剧增以及对石化能源过度依赖等问题正日益引起各行业的关注.占总能耗约1/3的建筑行业更需要有效的管理和使用可再生能源.本研究提出一个利用激光扫描技术识别和评估现有农村建筑实现零碳建筑的框架.该框架将点云数据转化为BIM模型,在获得现有建筑的BIM模型后,进行能源性能建模,并对现有农村建筑改造方案进行数字孪生评价.研究的目的是根据零碳建筑的概念对现有建筑改造方案进行评估,旨在提高当前建筑的能源利用效率,并利用清洁能源提供建筑能源需求.研究结果表明,适合本研究案例零碳建筑解决方案可以降低18.4%的建筑能源成本,提高24.1%的太阳能光伏发电量和降低能源需求6206.9 kgCO_(2) eq/a. 展开更多
关键词 零碳建筑 scan-to-BIM 数字孪生 建筑能耗模型 碳排放
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部