Magnetic nanoparticles used in headspace extraction coupled with DSI-GC-IT/MS for analysis of VOCs in dry Traditional Chinese Medicine 被引量:3
1
作者 Jing Nie Yuan-Jie Teng +2 位作者 Zu-Guang Li Wen-Han Liu Maw-Rong Lee 《Chinese Chemical Letters》 SCIE CAS CSCD 2016年第1期178-184,共7页
A novel magnetic method using polystyrene modified magnetic nanoparticles to perform thermoheadspace extraction was successfully developed for extraction and preconcentration of volatile organic components in dry Trad... A novel magnetic method using polystyrene modified magnetic nanoparticles to perform thermoheadspace extraction was successfully developed for extraction and preconcentration of volatile organic components in dry Traditional Chinese Medicine(TCM) based on gas chromatography-ion trap/mass spectrometry with a Chromato Probe direct sample introduction device. The dried fruit of Amomum testaceum Ridl. was used as the object TCM. The optimum parameters of headspace magnetic solid-phase extraction were investigated, in which desorption solvent ethyl acetate played a key role in this method,and the headspace extraction temperature of 90℃ and the headspace extraction time of 15 min finally decided. Headspace solid-phase microextraction method was also used to analyze volatile compounds in the TCM to compare with the proposed method. The results show that 60 components were identified totally by two methods; most of the low boiling point chemical compounds are isolated by this new method. In this work, an environmental-friendly and cheap analytical method was established, and a new approach to analyze volatile compounds in dry Traditional Chinese Medicine was also provided. 展开更多
关键词 Magnetic nanoparticles Direct sample introduction Volatile components Traditional Chinese Medicine
原文传递
Unfolded Frequency Response and Model of a Multi-Tap Direct Sampling Mixer
2
作者 潘赟 葛宁 董在望 《Tsinghua Science and Technology》 SCIE EI CAS 2008年第6期790-795,共6页
A transform method was used to model a discrete time multi-tap direct sampling mixer. The method transforms the mixed filtering and down-sampling stages to separate cascade filtering and sampling stages to determine t... A transform method was used to model a discrete time multi-tap direct sampling mixer. The method transforms the mixed filtering and down-sampling stages to separate cascade filtering and sampling stages to determine the unfolded frequency response which shows the anti-aliasing ability of the mixer. The trans-formation can also be applied to other mixed signal and multi-rate receiver systems to analyze their unfolded frequency responses. The transformed system architecture was used to calculate the unfolded frequency response of the multi-tap direct sampling mixer and compared with the mixer model without noise in the advanced design system 2005A environment to further evaluate the frequency response. The simulations show that the -3 dB bandwidth is 3.0 MHz and the voltage gain is attenuated by 1.5 dB within a 1-MHz baseband bandwidth. 展开更多
关键词 multi-tap direct sampling mixer TRANSFORMATION unfolded frequency response DECIMATION integral sampling