In order to study the control factors and mechanism of oolitic limestone reservoir being corroded by organic acid produced in burial stage,the reactions of acetic acid(pH=3)with oolitic limestone were investigated usi...In order to study the control factors and mechanism of oolitic limestone reservoir being corroded by organic acid produced in burial stage,the reactions of acetic acid(pH=3)with oolitic limestone were investigated using the rotating-disk Corrosion Reactor System(CRS).The effects of disk rotational speed,temperature and system pressure were examined.展开更多
文摘In order to study the control factors and mechanism of oolitic limestone reservoir being corroded by organic acid produced in burial stage,the reactions of acetic acid(pH=3)with oolitic limestone were investigated using the rotating-disk Corrosion Reactor System(CRS).The effects of disk rotational speed,temperature and system pressure were examined.