Swab culture monitoring of automated endoscope reprocessors after high-level disinfection 被引量:1
1
作者 Lung-Sheng Lu Yi-Chun Chiu +2 位作者 Ming-Tzung Lin Tsung-Hui Hu King-Wah Chiu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第14期1660-1663,共4页
AIM:To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors(AERs) after high-level disinfection(HLD).METHODS:From February 2006 to January 2011,authors conducted randomi... AIM:To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors(AERs) after high-level disinfection(HLD).METHODS:From February 2006 to January 2011,authors conducted randomized consecutive sampling each month for 7 AERs.Authors collected a total of 420 swab cultures,including 300 cultures from 5 gastroscope AERs,and 120 cultures from 2 colonoscope AERs.Swab cultures were obtained from the residual water from the AERs after a full reprocessing cycle.Samples were cultured to test for aerobic bacteria,anaerobic bacteria,and mycobacterium tuberculosis.RESULTS:The positive culture rate of the AERs was 2.0%(6/300) for gastroscope AERs and 0.8%(1/120) for colonoscope AERs.All the positive cultures,including 6 from gastroscope and 1 from colonoscope AERs,showed monofloral colonization.Of the gastroscopeAER samples,50%(3/6) were colonized by aerobic bacterial and 50%(3/6) by fungal contaminations.CONCLUSION:A full reprocessing cycle of an AER with HLD is adequate for disinfection of the machine.Swab culture is a useful method for monitoring AER decontamination after each reprocessing cycle.Fungal contamination of AERs after reprocessing should also be kept in mind. 展开更多
关键词 Automated endoscope reprocessor Gastrointestinal scope High-level disinfection Swab culture MONITORING DECONTAMINATION
暂未订购
苏州市34所医疗机构全自动内镜清洗消毒机清洗和消毒效果评价 被引量:1
2
作者 赵瑶 郭新怡 +7 位作者 杨波 陆建英 汪茜雅 金美娟 丁蔚 李慧 许圆 孙湘 《中华医院感染学杂志》 北大核心 2025年第2期281-285,共5页
目的了解医疗机构全自动内镜清洗消毒机(AER)的清洗效果和消毒效果,以期为医疗机构在使用和维护AER上提供数据支持。方法2023年9月—2024年4月对苏州市所有配备AER的医疗机构进行现场采样和检测,使用三磷酸腺苷(ATP)生物荧光检测法检测... 目的了解医疗机构全自动内镜清洗消毒机(AER)的清洗效果和消毒效果,以期为医疗机构在使用和维护AER上提供数据支持。方法2023年9月—2024年4月对苏州市所有配备AER的医疗机构进行现场采样和检测,使用三磷酸腺苷(ATP)生物荧光检测法检测AER清洗前后内镜表面和附件的清洗效果,使用蛋白残留法检测AER清洗前后内镜管腔的残留蛋白量,使用滤膜法检测内镜的消毒效果和AER内终末漂洗用水的情况,比较AER和手工两种方式消毒对内镜合格率的影响。结果共检测了34家医疗机构,43条消化内镜(胃镜27根,肠镜16根),内镜在AER清洗前后管腔的蛋白残留量平均值为51.82μg、35.38μg,表面ATP检测平均值为214 RLU、64 RLU,附件ATP检测平均值为126 RLU、32 RLU。ATP评价胃镜表面清洗前后合格率、内镜附件清洗前后合格率有统计学差异(P<0.05),管腔的蛋白残留在清洗前后未发现差别。使用AER消毒胃镜和肠镜的合格率分别为96.30%和87.50%,手工清洗消毒的胃镜和肠镜的合格率分别为100.00%和87.50%,使用AER和手工两种方式对消化内镜消毒后合格率未发现统计学差异。AER和手工的终末漂洗用水合格率分别为87.50%、80.00%。结论三级医疗机构的AER配置率较高,使用AER和手工两种方式对消化内镜消毒的效果无统计学差异,ATP生物荧光检测法和蛋白残留法评价AER清洗消化内镜效果尚可。建议多关注使用AER消毒的内镜和AER终末漂洗用水质量的定期监测。 展开更多
关键词 内镜 全自动内镜清洗消毒机 清洗消毒效果 三磷酸腺苷生物荧光检测法 蛋白残留法 终末漂洗用水
原文传递
292所医疗机构内镜自动清洗消毒机使用及管理现状调查
3
作者 甄静 陈刘吉 +3 位作者 刘海霞 马久红 李贤煌 黄茜 《中国感染控制杂志》 北大核心 2025年第9期1278-1285,共8页
目的 了解中国内镜自动清洗消毒机(AER)使用、管理及维护现状。方法 采用便利抽样法,对292所医疗机构消化内镜中心AER使用、管理、维护、监测,以及人员培训等方面进行问卷调查。结果 共发放问卷316份,有效回收292份,有效回收率92.41%。... 目的 了解中国内镜自动清洗消毒机(AER)使用、管理及维护现状。方法 采用便利抽样法,对292所医疗机构消化内镜中心AER使用、管理、维护、监测,以及人员培训等方面进行问卷调查。结果 共发放问卷316份,有效回收292份,有效回收率92.41%。292所医疗机构中198所(67.81%)配备AER,其中三级医疗机构AER配备率为75.11%,二级医疗机构AER配备率为41.27%。88.38%的医疗机构在内镜放入AER之前进行手工清洗,但仍有2.02%的医疗机构未执行该步骤,主要集中在三级医疗机构。AER使用中最常见的问题是连接管脱落或破损(83.33%),其次是AER漏消毒剂(43.94%)、控制面板失灵(43.94%)和AER管路不出水或出水不畅(42.93%)。92.42%的医疗机构定期对AER进行自身消毒,72.73%的医疗机构定期更换AER空气过滤器,80.30%的医疗机构定期更换AER水过滤器。96.46%的医疗机构每日使用AER之前进行消毒剂浓度监测,87.88%的医疗机构定期监测AER终末漂洗水,96.97%的医疗机构对新入职人员首次使用AER进行了专业培训。结论 中国各级医疗机构AER配备率有待提升,大部分医疗机构能够较好地监测和维护AER,但在使用过程中仍存在诸多问题。三级医疗机构因内镜诊疗量大,手工清洗执行率不足,需优化工作流程并加强培训。二级医疗机构则面临设备短缺、监测执行率低等挑战,需加大资金投入和监管力度。建议生产制造商不断优化AER设计,医疗机构建立AER标准化使用流程,相关部门完善AER使用及管理规范,以提升内镜清洗消毒质量,保障患者诊疗安全。 展开更多
关键词 内镜自动清洗消毒机 内镜 清洗 消毒 管理 现状调查
暂未订购
全自动内镜清洗消毒机消毒肠镜效果监测及风险因素分析 被引量:12
4
作者 刘珍如 吴安华 +5 位作者 豆清娅 龚瑞娥 汤紫媛 张莹 周凤 黄勋 《中国内镜杂志》 2022年第10期78-82,共5页
目的 对全自动内镜清洗消毒机(AER)消毒肠镜效果进行生物学监测,同时综合分析导致消毒失败的风险因素。方法 收集2013年1月-2022年7月该院AER清洗消毒肠镜内腔面及终末漂洗用水常规采样生物学监测数据。检测结果若超标,从内镜设备维护... 目的 对全自动内镜清洗消毒机(AER)消毒肠镜效果进行生物学监测,同时综合分析导致消毒失败的风险因素。方法 收集2013年1月-2022年7月该院AER清洗消毒肠镜内腔面及终末漂洗用水常规采样生物学监测数据。检测结果若超标,从内镜设备维护管理、终末漂洗用水管理、人员管理和消毒剂使用等方面查找消毒失败原因,并提出有针对性的改进措施。结果 AER清洗消毒肠镜生物学监测分别在2018年8月和2022年3月出现结果异常,前者经过5轮、后者经过1轮措施改进和复查之后监测达标;AER终末漂洗用水生物学监测分别在2019年12月和2022年3月出现结果异常,前者经过1轮、后者经过2轮措施改进和复查之后监测达标。内镜和终末漂洗用水生物学监测在2022年3月出现异常,经分析,内镜污染是由终末漂洗用水超标引起的。结论 通过根因分析,发现AER清洗消毒肠镜失败的主要风险因素为仪器老化和人员操作不规范等。通过建立设备检修保养制度和标准化操作程序等进行针对性管理,同时定期对内镜内腔面和终末漂洗用水进行生物学监测,能及时发现问题,避免了因内镜污染导致的相关感染,从而保障医疗质量与患者安全。 展开更多
关键词 全自动内镜清洗消毒机 肠镜 终末漂洗用水 感染
暂未订购
High-level disinfection of gastrointestinal endoscope reprocessing 被引量:15
5
作者 King-Wah Chiu Lung-Sheng Lu Shue-Shian Chiou 《World Journal of Experimental Medicine》 2015年第1期33-35,共3页
High level disinfection(HLD) of the gastrointestinal(GI)endoscope is not simply a slogan, but rather is a form of experimental monitoring-based medicine. By definition,GI endoscopy is a semicritical medical device. He... High level disinfection(HLD) of the gastrointestinal(GI)endoscope is not simply a slogan, but rather is a form of experimental monitoring-based medicine. By definition,GI endoscopy is a semicritical medical device. Hence,such medical devices require major quality assurance for disinfection. And because many of these items are temperature sensitive, low-temperature chemical methods, such as liquid chemical germicide, must be used rather than steam sterilization. In summarizing guidelines for infection prevention and control for GI endoscopy, there are three important steps that must be highlighted: manual washing, HLD with automated endoscope reprocessor, and drying. Strict adherence to current guidelines is required because compared to any other medical device, the GI endoscope is associated with more outbreaks linked to inadequate cleaning or disinfecting during HLD. Both experimental evaluation on the surveillance bacterial cultures and in-use clinical results have shown that, the monitoring of the stringent processes to prevent and control infection is an essential component of the broader strategy to ensure the delivery of safe endoscopy services, because endoscope reprocessing is a multistep procedure involving numerous factors that can interfere with its efficacy. Based on our years of experience in the surveillance of culture monitoring of endoscopic reprocessing, we aim in this study to carefully describe what details require attention in the GI endoscopy disinfection and to share our experience so that patients can be provided with high quality and safe medical practices. Quality management encompasses all aspects of pre- and postprocedural care including the efficiency of the endoscopy unit and reprocessing area, as well as the endoscopic procedure itself. 展开更多
关键词 Automated endoscope reprocessor Bacterial culture Gastrointestinal endoscopy High-level disinfection Liquid chemical germicide
暂未订购
DSD-201全自动内镜洗消机故障处理 被引量:1
6
作者 王建峰 丁江涛 从宁宁 《中国医疗设备》 2009年第3期111-112,共2页
本文简要介绍了美国明泰科DSD-201全自动内镜洗消机的工作过程,常见故障及处理办法。
关键词 全自动内镜洗消机 工作过程 故障检修
在线阅读 下载PDF
新内镜中心验收过程发现的问题及对策 被引量:8
7
作者 李占结 李松琴 +4 位作者 李琳 杨悦 陈文森 张永祥 刘波 《中国感染控制杂志》 CAS CSCD 北大核心 2019年第1期69-73,共5页
目的新内镜中心验收过程中模拟内镜清洗消毒流程,查找存在的问题并给予解决方案。方法新内镜中心验收中采用人工和全自动机清洗方法模拟内镜清洗消毒流程,对终末漂洗用纯水及清洗消毒后内镜进行微生物学检测,根据检测结果分析不合格原... 目的新内镜中心验收过程中模拟内镜清洗消毒流程,查找存在的问题并给予解决方案。方法新内镜中心验收中采用人工和全自动机清洗方法模拟内镜清洗消毒流程,对终末漂洗用纯水及清洗消毒后内镜进行微生物学检测,根据检测结果分析不合格原因并针对性进行改进。结果纯水供给管道消毒前后内镜终末漂洗用纯水检测合格率分别0、100%,染菌量中位数(四分位数)分别为200(186,213)、1. 5(0,6) CFU/100 m L,差异有统计学意义(P <0. 01)。酶液浓度调整前后人工清洗消毒内镜检测合格率分别为80. 00%、91. 67%。全自动内镜清洗消毒机(AER)自身消毒前后,自动清洗消毒机空载运行后水标本检测合格率分别为30%、100%,染菌量中位数(四分位数)分别为97. 5(8,175)、4(1. 75,6. 00) CFU/100 m L,差异有统计学意义(P <0. 01)。对管腔疑似有生物膜形成的内镜用2 000 mg/L过氧乙酸消毒后,合格率达100%。结论新内镜中心纯水供给管道未消毒、内镜清洗环节中酶液浓度错误、AER未进行自身消毒、内镜管腔生物膜形成是此次新内镜中心验收过程中发现的问题,针对性改进后,问题得到解决。为保障医疗安全和医疗质量,医疗机构应积极重视新内镜中心启用前的验收工作,消除造成内镜消毒不合格的危险因素。 展开更多
关键词 新内镜中心 验收 纯水管道 酶洗 自动清洗消毒机
暂未订购
大型煤泥浮选入料矿浆预处理器的设计 被引量:3
8
作者 张鹏 《煤炭技术》 CAS 北大核心 2016年第11期326-328,共3页
从分析矿浆预处理器的工作特点出发,以叶轮-桶体直径比值恒定和弗洛德数恒定建立几何相似模型和动力相似模型,以XY-1.6型预处理器为设计模型,确定相似模型中的经验常数,并运用模型设计开发了XY-3.8大型矿浆预处理器,设计结果符合矿浆预... 从分析矿浆预处理器的工作特点出发,以叶轮-桶体直径比值恒定和弗洛德数恒定建立几何相似模型和动力相似模型,以XY-1.6型预处理器为设计模型,确定相似模型中的经验常数,并运用模型设计开发了XY-3.8大型矿浆预处理器,设计结果符合矿浆预处理器的工艺要求。 展开更多
关键词 预处理器 相似放大 模型 弗洛德数
原文传递
内镜自动清洗消毒机两种不同循环模式对软式内镜再处理效果研究
9
作者 甄静 刘海霞 +3 位作者 陈刘吉 马久红 李贤煌 黄茜 《中国感染控制杂志》 2026年第1期100-107,共8页
目的比较内镜自动清洗消毒机(AER)两种循环模式对软式内镜再处理效果的影响,为临床选择最优清洗消毒方案提供循证依据。方法选取2024年6—10月江西省某三级甲等医院消化内镜中心胃肠镜检查后的206条内镜,采用随机数字表法分为A组(标准... 目的比较内镜自动清洗消毒机(AER)两种循环模式对软式内镜再处理效果的影响,为临床选择最优清洗消毒方案提供循证依据。方法选取2024年6—10月江西省某三级甲等医院消化内镜中心胃肠镜检查后的206条内镜,采用随机数字表法分为A组(标准循环模式,n=103)和B组(无洗涤循环模式,n=103),所有内镜均接受标准化处理(包括床旁预处理-转运-测漏-手工清洗-漂洗-目视检查),随后按分组采用AER循环模式进行处理。AER处理后,分别对活检通道、水/气通道及副送水通道进行微生物采样培养,主要观察指标包括消毒合格率、再处理时间及清洗消毒成本。结果A、B两组的消毒合格率分别为96.12%、92.23%,差异无统计学意义(χ2=1.42,P>0.05)。A、B两组单条内镜再处理时间分别为(46.98±0.64)、(34.02±0.66)min,差异具有统计学意义(t=143.65,P<0.001)。A、B两组的单位成本分别为45.81、42.65元,成本效益比(C/E)分别为49.09、47.63。增量成本效益分析显示,A组每提升1%合格率需额外投入83.67元(ICER=83.67)。微生物培养结果显示,两组检出菌种基本一致,主要为铜绿假单胞菌、嗜麦芽窄食单胞菌、恶臭假单胞菌及产气肠杆菌等条件致病菌。结论在标准化手工清洗基础上,AER两种循环模式对软式内镜再处理效果无显著差异,标准循环模式中补充清洗所提供的安全级别有限,各级医疗机构应高度重视内镜放入AER之前的手工清洗。AER中无洗涤循环模式相较于标准循环模式可节约内镜再处理时间和清洗消毒成本,在严格遵循标准化手工清洗流程的前提下,各级医疗机构综合考虑成本和内镜周转需求时,可以选择无洗涤循环模式。 展开更多
关键词 内镜自动清洗消毒机 软式内镜 循环模式 再处理
暂未订购
OER-AW型内镜清洗消毒装置的原理与维修保养 被引量:2
10
作者 张权明 《中国医疗器械信息》 2023年第17期169-172,共4页
目的:阐述医院内镜中心OER-AW型内镜清洗消毒装置的原理并进行故障分析,提高对清洗消毒装置的维护管理水平。方法:介绍OER-AW内镜清洗消毒装置的工作原理、结构构成、清洗流程,结合故障维修的案例分析,提出改进措施。结果:如果希望有效... 目的:阐述医院内镜中心OER-AW型内镜清洗消毒装置的原理并进行故障分析,提高对清洗消毒装置的维护管理水平。方法:介绍OER-AW内镜清洗消毒装置的工作原理、结构构成、清洗流程,结合故障维修的案例分析,提出改进措施。结果:如果希望有效降低清洗消毒装置的故障次数,提升设备使用效率,提高软式内镜清洗消毒质量,就需要加深对设备原理的认识,及时总结维修经验,做好日常保养和定期保养。结论:对OER-AW型内镜清洗消毒装置进行合理有效的管理,有利于提升内镜中心软式内镜洗消周转率,保障清洗消毒效果,有利于提高工程技术人员的维护管理水平,为科室提供快速的技术保障和良好的使用建议。 展开更多
关键词 内镜清洗消毒装置 原理 故障维修 保养
暂未订购