期刊文献+
共找到1,115篇文章
< 1 2 56 >
每页显示 20 50 100
A Simple Analytic Approximation for the Refracted Field at Gaussian Beam Incidence upon a Boundary of Absorbing Medium
1
作者 Vladimir M. Serdyuk Joseph A. Titovitsky 《Journal of Electromagnetic Analysis and Applications》 2010年第11期640-648,共9页
An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The a... An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The analytic solution is obtained by asymptotic approximation of a Fourier field integral under the condition of great beam width in comparison with a wavelength (the geometrical-optics approximation). This model can be used also for approximate simulation of refracted field in the cases of beam incidence near the critical angle on transparent or absorbing (amplifying) refracting medium, if one artificially introduces the additional absorption (amplification), whose value is proportional to the ratio of the wavelength and the effective beam width. It is shown that the analytic model reflects the general features of refracted field at total internal reflection. 展开更多
关键词 GAUSSIAN Beam REFRACTION Absorbing Medium Total Internal REFLECTION
在线阅读 下载PDF
Propagation characteristics of converted refracted wave and its application in static correction of converted wave 被引量:7
2
作者 LIU Yang WEI XiuCheng 《Science China Earth Sciences》 SCIE EI CAS 2008年第S2期226-232,共7页
Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration.In three-component seismic exploration data processing,one of ... Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration.In three-component seismic exploration data processing,one of the difficulties is static correction of converted wave.This paper analyzes propagation characteristics of non-converted and converted refracted waves,and discovers a favor-able condition for the formation of converted refracted wave,i.e.the velocity of overlaying medium S wave is much lower than that of underlying medium S wave.In addition,the paper proposes the static correction method of converted wave based on PPS converted refracted wave,and processes the real three-component seismic data with better results of static correction of converted wave. 展开更多
关键词 PPS converted refracted wave converted wave static correction
原文传递
Total score of the computer vision syndrome questionnaire predicts refractive errors and binocular vision anomalies
3
作者 Mosaad Alhassan Tasneem Samman +5 位作者 Hatoun Badukhen Muhamad Alrashed Balsam Alabdulkader Essam Almutleb Tahani Alqahtani Ali Almustanyir 《International Journal of Ophthalmology(English edition)》 2026年第1期90-96,共7页
AIM:To evaluate the efficacy of the total computer vision syndrome questionnaire(CVS-Q)score as a predictive tool for identifying individuals with symptomatic binocular vision anomalies and refractive errors.METHODS:A... AIM:To evaluate the efficacy of the total computer vision syndrome questionnaire(CVS-Q)score as a predictive tool for identifying individuals with symptomatic binocular vision anomalies and refractive errors.METHODS:A total of 141 healthy computer users underwent comprehensive clinical visual function assessments,including evaluations of refractive errors,accommodation(amplitude of accommodation,positive relative accommodation,negative relative accommodation,accommodative accuracy,and accommodative facility),and vergence(phoria,positive and negative fusional vergence,near point of convergence,and vergence facility).Total CVS-Q scores were recorded to explore potential associations between symptom scores and the aforementioned clinical visual function parameters.RESULTS:The cohort included 54 males(38.3%)with a mean age of 23.9±0.58y and 87 age-matched females(61.7%)with a mean age of 23.9±0.53y.The multiple regression model was statistically significant[R²=0.60,F=13.28,degrees of freedom(DF=17122,P<0.001].This indicates that 60%of the variance in total CVS-Q scores(reflecting reported symptoms)could be explained by four clinical measurements:amplitude of accommodation,positive relative accommodation,exophoria at distance and near,and positive fusional vergence at near.CONCLUSION:The total CVS-Q score is a valid and reliable tool for predicting the presence of various nonstrabismic binocular vision anomalies and refractive errors in symptomatic computer users. 展开更多
关键词 computer vision syndrome refractive errors ACCOMMODATION VERGENCE binocular vision SYMPTOMS
原文传递
Epidemiological investigative report on ocular morbidity in children in rural Kenya
4
作者 Marlene E.Long Lily A.Nyamai +3 位作者 Marina Marinkovic Nanda Horeweg Brian W.Fleck Martine J.Jager 《International Journal of Ophthalmology(English edition)》 2026年第1期115-122,共8页
AIM:To ascertain the pattern of ocular morbidity in a population of primary school children in rural Kenya as it is a prerequisite for planning effective preventive and therapeutic strategies.METHODS:A cross-sectional... AIM:To ascertain the pattern of ocular morbidity in a population of primary school children in rural Kenya as it is a prerequisite for planning effective preventive and therapeutic strategies.METHODS:A cross-sectional survey of ocular symptoms and clinical eye examinations were performed in a sample of 35 rural primary schools in the semi-arid region of Kajiado West sub-county in S.W.Kenya,amongst a seminomadic tribe(Maasai).Students in Grades 1-8 were included.Visual acuity was measured using the Snellen“tumbling E”chart at 6 m.Children with symptoms of refractive error underwent non-cycloplegic refraction.RESULTS:A total of 2036 children(1084 males)between the ages of 4-20y were examined.Conjunctival actinic changes were present in 22%(442/2036).Nine cases were seen with a potential squamous carcinoma.No overt classical ocular signs of vitamin A deficiency were noted,although 181(8.9%)children complained of nyctalopia.Three hundred thirty-six(16.5%)children had a visual acuity worse than 6/12 in either eye,were unable to read N10 near text at 40 cm or had symptoms suggestive of refractive error.Refractive data led to an estimate of hyperopia of+1.00 D or more in 3.9%and of myopia of-0.50 D or more in either eye in 3.0%of the study population.CONCLUSION:Solar exposure-and dust-related conjunctival pathology is common.As this may develop into potentially sight-or even life-threatening conditions,it warrants further study,and preventive strategies may be needed.Complaints of nyctalopia were common and could suggest vitamin A deficiency.The prevalence of refractive errors is low in this rural African population. 展开更多
关键词 ocular morbidity epidemiological investigation actinic conjunctival changes refractive error rural Kenyan children
原文传递
Postoperative effective lens position and refraction changes with three different types of intraocular lens
5
作者 Xi-Xia Ding Lin-Feng Xiang +5 位作者 Wen-Tao Tong Dan-Dan Wang Hong-FangZhang Ping-Jun Chang Fu-Man Yang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 2026年第2期260-265,共6页
AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 group... AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 groups:Group A(implanted with the SN6CWS),Group B(implanted with the MI60),and Group C(implanted with the Aspira-aA).ELP measurements were obtained with swept-source optical coherence tomography(SS-OCT)at 1d,1wk,1mo,and 3mo postoperatively.Subjective refraction assessments were conducted at 1wk,1mo,and 3mo following surgery.RESULTS:The study included 189 eyes of 150 cataract patients(66 males).There were 77 eyes in Group A,55 eyes in Group B,and 57 eyes in Group C.The root mean square of the ELP(ELPRMS)within the initial 3mo was significantly lower for Group A than for Groups B and C.Refractive changes within Group A were not significant across the time points of 1wk,1mo,and 3mo.Conversely,both Group B and Group C demonstrated statistically significant shifts toward hyperopia from 1wk to 3mo postsurgery.CONCLUSION:Among the three IOLs examined,the SN6CWS IOL showes the greatest stability during the first 3mo postoperatively.Between 1wk and 3mo after surgery,notable hyperopic shifts are evident in eyes implanted with the MI60 and Aspira-aA IOLs,whereas refractive outcomes remain relatively constant in eyes implanted with SN6CWS IOLs. 展开更多
关键词 effective lens position REFRACTION intraocular lens swept-source optical coherence tomography
原文传递
Flap amputation for severe epithelial ingrowth post-LASIK:a case report
6
作者 Mohamed Hosny Wessam Salem 《International Journal of Ophthalmology(English edition)》 2026年第1期197-198,共2页
Dear Editor,We present this case report which discusses a patient who underwent flap amputation after repeated attempts to resolve persistent and severe epithelial ingrowth following laser-assisted in situ keratomileu... Dear Editor,We present this case report which discusses a patient who underwent flap amputation after repeated attempts to resolve persistent and severe epithelial ingrowth following laser-assisted in situ keratomileusis(LASIK)surgery.Epithelial ingrowth is a known complication of LASIK surgery,typically manageable with minimal measures.However,severe cases may necessitate more aggressive interventions,such as flap amputation[1].LASIK is a widely performed refractive surgery with high success rates and excellent visual outcome[2]. 展开更多
关键词 refractive surgery LASIK flap amputation lasik flap amputation laser assisted situ keratomileusis epithelial ingrowth
原文传递
CORRIGENDUM
7
《International Journal of Ophthalmology(English edition)》 2026年第2期378-378,392,404,共3页
Ocular biological characteristics and refractive errors in children with unilateral congenital ptosis Yu-Ying Sun,Bing-Ying Lin,Zhen Mao,Xuan-Wei Liang,Cui-Yu Zhang,Dan-Ping Huang,Yao Ni,Zuo-Hong Li Int J Ophthalmol 2... Ocular biological characteristics and refractive errors in children with unilateral congenital ptosis Yu-Ying Sun,Bing-Ying Lin,Zhen Mao,Xuan-Wei Liang,Cui-Yu Zhang,Dan-Ping Huang,Yao Ni,Zuo-Hong Li Int J Ophthalmol 2025;18(4):691-698.DOI:10.18240/ijo.2025.04.16 The author requests to change the authorship and affiliations as follows. 展开更多
关键词 ocular biological characteristics authorship affiliations unilateral congenital ptosis refractive errors
原文传递
Digital light processing 3D printing of ceramics for W-band gradient refractive index metalens
8
作者 Wuzhao Li Siqian Wu +2 位作者 Jin Chen Rong Wang Qi Ge 《International Journal of Extreme Manufacturing》 2026年第1期601-616,共16页
Gradient refractive index(GRIN)metalenses are increasingly valued in high-frequency communication due to their exceptional radiation performance.Ceramics with high dielectric constants and low dielectric losses are id... Gradient refractive index(GRIN)metalenses are increasingly valued in high-frequency communication due to their exceptional radiation performance.Ceramics with high dielectric constants and low dielectric losses are ideal candidates for GRIN metalenses.Digital light processing(DLP)3D printing provides a feasible and efficient approach for manufacturing ceramic GRIN metalenses.However,the scattering of ultraviolet(UV)light by ceramic particles in the slurry reduces the printing accuracy of DLP technology,making it difficult to achieve the intricate structural features required for GRIN metalenses in high-frequency communication.In this work,we propose an approach to improve printing accuracy by optimizing the ceramic slurry composition and implementing a dimensional compensation design strategy.Utilizing geometric optics and the S-parameter inversion method,we design a GRIN metalens consisting of two distinct types of subwavelength unit cells(Y-shaped and circular hole geometries)with a minimum feature size of 160μm.Through a refined slurry formulation and precise design parameter compensation,high-fidelity ceramic GRIN metalenses are successfully fabricated.The fabricated metalens exhibits a maximum gain enhancement of 18.4 dBi and a deflection angle of±30°over a bandwidth of 37.84% in the W-band(75-110 GHz).The highly directional far-field beam radiation and efficient beam steering capabilities highlight the potential of ceramic GRIN metalenses for applications in satellite communications,radar systems,and other high-frequency technologies. 展开更多
关键词 3D printing CERAMICS digital light processing gradient refractive index metalens
在线阅读 下载PDF
Highly sensitive,multi-stage,and mid-infrared refractive index sensor based on photonic spin Hall effect
9
作者 Jiaye Ding Chenglong Wang +2 位作者 Shengli Liu Peng Dong Jie Cheng 《Chinese Physics B》 2026年第1期432-438,共7页
Surface polaritons,as surface electromagnetic waves propagating along the surface of a medium,have played a crucial role in enhancing photonic spin Hall effect(PSHE)and developing highly sensitive refractive index(RI)... Surface polaritons,as surface electromagnetic waves propagating along the surface of a medium,have played a crucial role in enhancing photonic spin Hall effect(PSHE)and developing highly sensitive refractive index(RI)sensors.Among them,the traditional surface plasmon polariton(SPP)based on noble metals limits its application beyond the near-infrared(IR)regime due to the large negative permittivity and optical losses.In this contribution,we theoretically proposed a highly sensitive PSHE sensor with the structure of Ge prism-SiC-Si:InAs-sensing medium,by taking advantage of the hybrid surface plasmon phonon polariton(SPPhP)in mid-IR regime.Here,heavily Si-doped InAs(Si:InAs)and SiC excite the SPP and surface phonon polariton(SPhP),and the hybrid SPPhP is realized in this system.More importantly,the designed PSHE sensor based on this SPPhP mechanism achieves the multi-stage RI measurements from 1.00025-1.00225 to 1.70025-1.70225,and the maximal intensity sensitivity and angle sensitivity can be up to 9.4×10^(4)μm/RIU and245°/RIU,respectively.These findings provide a new pathway for the enhancement of PSHE in mid-IR regime,and offer new opportunities to develop highly sensitive RI sensors in multi-scenario applications,such as harmful gas monitoring and biosensing. 展开更多
关键词 refractive index(RI)sensor photonic spin Hall effect MID-IR MULTI-STAGE
原文传递
Fiber-optic microstructured sensors based on abrupt field patterns: theory, fabrication, and applications
10
作者 Yuxuan Yi Wanlai Zhu +4 位作者 Zao Yi Zigang Zhou Shubo Cheng Majid Niaz Akhtar Sohail Ahmad 《Opto-Electronic Science》 2026年第1期13-31,共19页
Fiber-optic sensing technology has the advantages of passivity, anti-electromagnetic interference, longdistancemeasurement, high sensitivity and high accuracy, small size, and adaptability to harsh environments such a... Fiber-optic sensing technology has the advantages of passivity, anti-electromagnetic interference, longdistancemeasurement, high sensitivity and high accuracy, small size, and adaptability to harsh environments such ashigh-vacuum, high-pressure, and strong magnetic fields compared with the traditional electrical sensing technology.However, with the increasing application requirements, how to further improve the sensitivity of fiber-optic sensors,extend the detection limit and improve the maintenance-free capability has become one of the core issues of thecurrent research. This paper reviews the principle, preparation, and application of fiber-optic microstructured sensingbased on abrupt field type. It specifically outlines the development and applications of micro-nano optical fibers,photonic crystal optical fibers, optical fiber gratings and structured optical fibers, and lists the main preparationmethods of two types of micro-nano optical fibers from the basic theory of optical fiber microstructured sensordevices. 展开更多
关键词 fiber-optic microstructure sensing sudden field-type fiber-optic microstructure devices fiber-optic refractive index sensors micro-and nanofibers Wiener fiber preparation
在线阅读 下载PDF
Visual function and optical quality after bilateral implantation of zonal refractive multifocal IOL in elderly patients
11
作者 Chen Jun Qiu Xinying +1 位作者 Zhu Jie Wei Yuanjian 《国际眼科杂志》 2026年第4期551-557,共7页
AIM:To evaluate the visual function and optical quality in adults aged 80y and older following the bilateral implantation of zonal refractive multifocal intraocular lens(IOL,LS-313 MF30).METHODS:A single-center,non-ra... AIM:To evaluate the visual function and optical quality in adults aged 80y and older following the bilateral implantation of zonal refractive multifocal intraocular lens(IOL,LS-313 MF30).METHODS:A single-center,non-randomized,prospective clinical trial was conducted,involving cataract patients aged 80 y and older.Patients received bilateral implantation of the LS-313 MF30 or CT Asphina 409MP,based on personal preference.Postoperative assessments included uncorrected and corrected visual acuity at distance,intermediate,and near ranges,as well as defocus curve.Subjective evaluations were performed using the visual function(VF-14)questionnaire,spectacle independence rates,and patient satisfaction surveys.Photic phenomena such as glare,halos,and starbursts were also analyzed.RESULTS:The MF30 group(16 eyes from 8 participants,85.38±2.56 y)exhibited superior uncorrected and corrected intermediate and near visual acuity compared to the 409MP group(26 eyes from 13 participants,85.77±2.20 y),while distance visual acuity was comparable between groups.The defocus curve of the MF30 group revealed two peaks at 0.00 D and-3.00 D,indicating a broader depth of focus.Patients in the MF30 group reported higher rates of spectacle independence and greater satisfaction.While photic phenomena such as glare(28.6%vs 18.5%,P=0.584),starburst(9.5%vs 3.7%,P=0.567)and halos(23.8%vs 11.11%,P=0.438)were more prevalent in the MF30 group,they were generally mild and did not significantly impact daily activities.CONCLUSION:Zonal refractive multifocal IOLs provide elderly patients with improved distance and near vision,greater spectacle independence,and greater satisfaction.Although photic phenomena were slightly more frequent with MF30,they are generally reported as non-disruptive and do not affect their daily life compared to monofocal IOLs. 展开更多
关键词 zonal refractive multifocal intraocular lens aged 80 years and older LS-313 MF30 cataract surgery non-randomized prospective clinical trial
暂未订购
Binocular vision disorders and refractive errors on university students’quality of life 被引量:1
12
作者 Raheleh Moravej Alireza Jamali +6 位作者 Navidreza Zamani Fatemeh Azad Shahraki Abbas Ali Yekta Hadi Ostadimoghaddam Nasim Vaghefi Hamidreza Ghadimi Mehdi Khabazkhoob 《International Journal of Ophthalmology(English edition)》 2025年第4期707-715,共9页
AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students usin... AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students using simple random sampling.Objective refraction,ocular alignment,vergence and accommodative performance were measured and assessed in all participants.Data on QOL were collected using the College of Optometrists in Vision Development-Quality of Life(COVD-QOL)Questionnaire.The effect of mentioned parameters on the QOL were evaluated.RESULTS:Totally 726 students with mean age of 21.35±1.88y were evaluated in this study,51.5%of whom were female.Esophoria was caused significantly lower QOL in the domains of somatic symptoms and occupationalphysical symptoms(P<0.05);Besides,esotropia decreased QOL in domains of somatic symptoms P=0.002 and psychological factors(P=0.023).Students with accommodation insufficiency experienced more symptoms in all domains(P<0.05)except for psychological factors(P=0.07).Increasing in the near point of convergence and accommodation and decreases QOL and increasing accommodative facility increases QOL(all P<0.05).Myopia and astigmatism cause decrease in QOL(both P<0.05),but hyperopic students had better QOL in comparison with others(P<0.05).CONCLUSION:Screening programs and treatment of refractive errors and binocular vision anomalies,especially phoria and accommodative insufficiency,positively impact the QOL and academic achievements of university students. 展开更多
关键词 quality of life binocular vision disorders refractive errors ACCOMMODATION CONVERGENCE university students
原文传递
Structural, electronic, and optical studies of chalcogenides stannite Cu_(2)CdSnX_(4)(X=S, Se, and Te): insights from the DFT study 被引量:1
13
作者 Jamal GUERROUM Mohamed AL-HATTAB +3 位作者 Lhoucine MOUDOU Khalid RAHMANI Youssef LACHTIOUI Omar BAJJOU 《Optoelectronics Letters》 2025年第2期69-76,共8页
In this paper,we have calculated the structural,electronic,and optical properties of chalcogenide stannite Cu_(2)CdSnX4(X=S,Se,Te) materials.The calculations are based on the density functional theory (DFT) method and... In this paper,we have calculated the structural,electronic,and optical properties of chalcogenide stannite Cu_(2)CdSnX4(X=S,Se,Te) materials.The calculations are based on the density functional theory (DFT) method and are performed using the Cambridge sequential total energy package (CASTEP) code included in the Biovia Material Studio 20 software.All optical properties have been studied in a domain that extends energetically from 10 meV to 40 eV.Our results show that Cu_(2)CdSnX4(X=S,Se,Te) stannite exhibits absorption in the visible region,the refractive index decreases with increasing energy,and the refractive index values are n=3.2,3.73 and 3.75 for Cu_(2)CdSnS_(4),Cu_(2)CdSnSe_(4)and Cu_(2)CdSnTe_(4),respectively.They show also high conductivity,which implies that this material is promising for solar cells.These results argue in favor of the use of these materials in various potential applications.The density of state,band structures,and structural properties of Cu_(2)CdSnX4(X=S,Se,and Te) stannite are also studied in this work. 展开更多
关键词 materials ELECTRONIC refractive
原文传递
Posterior chamber phakic intraocular lens adjustmentcauses and complications:a retrospective cohort study 被引量:1
14
作者 Ghufran Alarfaj Halah Bin Helayel +6 位作者 Majed AlSubaie Jumana Hariri Fatima Alzaher Omar Khan Mohanna Al-Jindan Ahmed AlHabash Naif M Sulaimani 《International Journal of Ophthalmology(English edition)》 2025年第5期883-888,共6页
AIM:To evaluate the visual outcomes of implantable collamer lenses(ICLs)and identify the possible risk factors for ICL axis misalignment,and consequently,repositioning,explanting,or exchanging at a specialized eye hos... AIM:To evaluate the visual outcomes of implantable collamer lenses(ICLs)and identify the possible risk factors for ICL axis misalignment,and consequently,repositioning,explanting,or exchanging at a specialized eye hospital in Saudi Arabia.METHODS:The medical records of 813 eyes with different refractive errors corrected with ICL implantation were identified and included in this single-arm retrospective cohort study.The following data were collected:demographic characteristics,primary diagnosis,preoperative refraction,anterior chamber depth(ACD),white-to-white(WTW)measurement,endothelial cell density(ECD),and axial length.Patients’satisfaction and complaints,and their postoperative refraction,vault depth,and axis alignment with the preoperative target,were reviewed during the postoperative period.Collectively,these data were correlated with symptomatic axis rotation and the need for repositioning,explantation,or exchange due to high or low ICL vaults.RESULTS:Of 813 eyes,27(3.32%),13(1.59%),and 11(1.35%)required ICL repositioning,ICL explantation only without exchange,and ICL explantation with the placement of a new ICL,respectively.The mean follow-up period was 37.5mo.The main cause of explanation or exchange was incorrect WTW measurement in seven(29.17%)eyes,followed by high vault in four(16.56%)eyes.ICL repositioning was required in 27(3.32%)eyes with considerable rotation.Only 2(0.24%)eyes developed cataracts that required ICL removal,and retinal complications were reported in 7(0.86%)eyes.Long-term glaucoma and corneal decompensation were not observed in this cohort.CONCLUSION:With a high safety profile and reversibility,ICL implantation is a good alternative to corneal-based refractive surgery in eyes unsuitable for laser vision correction.The rate of secondary procedures in our study was 6.26%.Old age is a risk factor for secondary surgical interventions in the repositioning group,whereas abnormal vault and toric ICL rotation in the explantation group necessitated subsequent surgical procedures.Overall,ICL implantation demonstrates a good efficacy index and safety profile in patients with diverse refractive errors. 展开更多
关键词 lens-based surgery refractive error correction COMPLICATIONS myopic correction hyperopic correction
原文传递
Multi-Fano resonances sensing based on a non-through metal-insulatormetal waveguide coupling D-shaped cavity
15
作者 ZHAO Xiao-long CHANG Xu-yan +2 位作者 LIU Yan-li ZHANG Yan-Jun ZHANG Zhi-dong 《中国光学(中英文)》 北大核心 2025年第6期1484-1494,共11页
A plasmonics waveguide structure that consist of a non-through metal–insulator–metal(MIM)waveguide coupled with a D-shaped cavity was designed.And the transmission properties,magnetic field distribution,and refracti... A plasmonics waveguide structure that consist of a non-through metal–insulator–metal(MIM)waveguide coupled with a D-shaped cavity was designed.And the transmission properties,magnetic field distribution,and refractive index sensing functionality were simulated using the finite element method(FEM).A multi-Fano resonance phenomenon was clearly observable in the transmission spectra.The Fano resonances observed in the proposed structure arise from the interaction between the discrete states of the Dshaped resonant cavity and the continuum state of the non-through MIM waveguide.The influence of structural parameters on Fano resonance modulation was investigated through systematic parameter adjustments.Additionally,the refractive index sensing properties,based on the Fano resonance,were investigated by varying the refractive index of the MIM waveguide's insulator layer.A maximum sensitivity and FOM of 1155 RIU/nm and 40 were achieved,respectively.This research opens up new possibilities for designing and exploring high-sensitivity photonic devices,micro-sensors,and innovative on-chip sensing architectures for future applications. 展开更多
关键词 surface plasmon polaritons metal-insulator-metal(MIM)waveguide D-shaped resonant cavity double Fano resonance refractive index sensor
在线阅读 下载PDF
Optofluidic refractive index sensor with microtube-coupled suspended core fiber
16
作者 WAN Jing HUIYongxiang +2 位作者 GAO Lizao ZHANG Wei WAN Hongdan 《Optoelectronics Letters》 2025年第10期589-594,共6页
Based on optofluidics and whispering gallery mode(WGM)theory,here an optofluidic refractive index sensor with microtube-coupled suspended core fiber(SCF)is proposed.It solves the issues of general sensors with microca... Based on optofluidics and whispering gallery mode(WGM)theory,here an optofluidic refractive index sensor with microtube-coupled suspended core fiber(SCF)is proposed.It solves the issues of general sensors with microcavity-coupled fiber taper such as too fragile,unstable performance due to open coupling,poor portability and repeatability,while overcoming the poor performance of low refractive index sensing in general full-package fiber sensors.The sensor only needs a very small amount of liquid sample(about 1.8 nL).The proposed sensor combines the excellent performance of full package,optofluidics and WGM resonator.The resonant characteristics and sensing performance of the sensor are analyzed and discussed by the theoretical simulation.The simulation results indicate that the sensor has a wide refractive index sensing range(1.330-1.700)and good performance.The resonance wavelength shift has a good linear relationship with the liquid refractive index variation.In the low refractive index region,the sensitivity is 222.5-247.5 nm/RIU,Q-factor is 1.03×10^(3) and the detection limit is 3.64×10^(-4) RIU.In the medium and high refractive index regions,the sensitivity is 564.4-846.2 nm/RIU,Q-factor is up to 8.62×10^(4),and the detection limit can be as low as 1.29×10^(-6) RIU.The sensor exhibits a high sensitivity,a high Q-factor and a very low detection limit. 展开更多
关键词 whispering gallery mode wgm theoryhere theoretical simulation whispering gallery mode microtube coupled suspended core fiber optofluidic refractive index sensor low refractive index sensing sensing performance refractive index sensing range
原文传递
Vision care and the sustainable development goals: a brief review and suggested research agenda
17
作者 Nathan Congdon Brad Wong +1 位作者 Xinxing Guo Graeme MacKenzie 《Eye Science》 2025年第2期103-110,共8页
Blindness affected 45 million people globally in 2021,and moderate to severe vision loss a further 295 million.[1]The most common causes,cataract and uncorrected refractive error,are generally the easiest to treat,and... Blindness affected 45 million people globally in 2021,and moderate to severe vision loss a further 295 million.[1]The most common causes,cataract and uncorrected refractive error,are generally the easiest to treat,and are among the most cost-effective procedures in all of medicine and international development.[1-2]Thus,vision impairment is both extremely common and,in principle,readily manageable. 展开更多
关键词 vision care CATARACT cost effective procedures uncorrected refractive error BLINDNESS moderate severe vision loss uncorrected refractive errorare sustainable development goals
暂未订购
Predictive factors for outcomes of photorefractive keratectomy in myopic eyes
18
作者 Seyyed Saeed Shams Samira Hassanzadeh +2 位作者 Siamak Zarei-Ghanavati Mohammed Ziaei Soroush Bayati 《International Journal of Ophthalmology(English edition)》 2025年第11期2143-2148,共6页
AIM:To analyze the two-year visual and refractive outcomes as well as the safety,and efficacy of photorefractive keratectomy(PRK)surgery for myopia.METHODS:In this prospective cohort study,63 eligible patients were re... AIM:To analyze the two-year visual and refractive outcomes as well as the safety,and efficacy of photorefractive keratectomy(PRK)surgery for myopia.METHODS:In this prospective cohort study,63 eligible patients were recruited,including 45 women(71.4%)and 18 men(28.6%).Demographic characteristics along with pre-and post-operative clinical data including visual acuity,refraction,maximum ablation,spherical and cylindrical error,and residual stromal bed(RSB)were evaluated.RESULTS:The mean age of the patients was 35.42±8.16y(range 22 to 55y).The mean spherical and cylindrical error before surgery were-2.23±1.58 D(range-5 to+0.25)and-1.24±0.94 D,respectively(range-3.75 to 0.00).The mean efficacy and safety of PRK surgery at 2y follow-up were 0.98±0.06 and 1.01±0.04 respectively.The lower age was significantly correlated with a higher amount of efficacy index(P<0.001,r=-0.42).Also,the lower amount of preoperative myopia and spherical equivalent(SE)were correlated with a higher safety index(P<0.001,r=-0.44;P<0.001,r=-0.46).CONCLUSION:The two-year efficacy and safety of PRK for the treatment of low myopia is excellent.Younger age and lower amount of refractive error are correlated with higher efficacy and safety indices of the surgery. 展开更多
关键词 photorefractive keratectomy MYOPIA refractive error refractive surgery
原文传递
Plasmonic dual-parameter biosensor with self-referencing capability based on one-dimensional metal gratings
19
作者 LIU Jun LUO Jianhua 《Optoelectronics Letters》 2025年第8期449-454,共6页
There is limited amount of research on surface plasmon resonance(SPR)sensors with self-referencing capabilities which are based on dielectric gratings.In the short-wavelength range,a metal grating sensor is capable of... There is limited amount of research on surface plasmon resonance(SPR)sensors with self-referencing capabilities which are based on dielectric gratings.In the short-wavelength range,a metal grating sensor is capable of simultaneously measuring liquid refractive index under proposed temperature.A fabricated gold grating is placed on one side of a thin gold film for refractive index measurement,while the other with polydimethylsiloxane(PDMS)is deposited on the other side for temperature measurement.We use finite element analysis to research its sensing characteristics.Due to the high refractive index sensitivity of SPR sensors and thermo-optic coefficient of PDMS,we discovered the maximum spectral sensitivity of the sensor is 564 nm/RIU and-50 pm/℃when the liquid refractive index ranges from 1.30 to 1.40 with temperature ranging from 0℃ to 100℃.Numerical results indicate that there may not be mutual interference between two channels for measuring refractive index and temperature,which reduces the complexity of sensor measurements. 展开更多
关键词 thin gold film fabricated gold grating plasmonic biosensor metal grating sensor liquid refractive index self referencing capability refractive index dielectric gratingsin
原文传递
High sensitivity and low refractive index D-type photonic crystal fiber sensor based on surface plasmon resonance
20
作者 GAO Jiachen MING Xianbing WEN Xiang 《Optoelectronics Letters》 2025年第9期528-534,共7页
A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electro... A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electrons in a metal are resonated with photons.The structural parameters are fine-tuned and the sensing performance of the sensor is studied.The results show that the maximum spectral sensitivity reaches 18 000 nm/RIU in the refractive index range of 1.24—1.32,and the maximum resolution is 5.56×10^(-6) RIU.The novel structure with high sensitivity and low refractive index provides a new perspective for fluid density detection. 展开更多
关键词 high sensitivity d type photonic crystal fiber surface plasmon resonance spr gold film maximum resolution refractive index low refractive index surface plasmon resonance
原文传递
上一页 1 2 56 下一页 到第
使用帮助 返回顶部