An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The a...An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The analytic solution is obtained by asymptotic approximation of a Fourier field integral under the condition of great beam width in comparison with a wavelength (the geometrical-optics approximation). This model can be used also for approximate simulation of refracted field in the cases of beam incidence near the critical angle on transparent or absorbing (amplifying) refracting medium, if one artificially introduces the additional absorption (amplification), whose value is proportional to the ratio of the wavelength and the effective beam width. It is shown that the analytic model reflects the general features of refracted field at total internal reflection.展开更多
Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration. In three-component seismic exploration data processing,one of...Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration. In three-component seismic exploration data processing,one of the difficulties is static correction of converted wave. This paper analyzes propagation characteristics of non-converted and converted refracted waves,and discovers a favor-able condition for the formation of converted refracted wave,i.e. the velocity of overlaying medium S wave is much lower than that of underlying medium S wave. In addition,the paper proposes the static correction method of converted wave based on PPS converted refracted wave,and processes the real three-component seismic data with better results of static correction of converted wave.展开更多
AIM:To evaluate the visual outcomes of implantable collamer lenses(ICLs)and identify the possible risk factors for ICL axis misalignment,and consequently,repositioning,explanting,or exchanging at a specialized eye hos...AIM:To evaluate the visual outcomes of implantable collamer lenses(ICLs)and identify the possible risk factors for ICL axis misalignment,and consequently,repositioning,explanting,or exchanging at a specialized eye hospital in Saudi Arabia.METHODS:The medical records of 813 eyes with different refractive errors corrected with ICL implantation were identified and included in this single-arm retrospective cohort study.The following data were collected:demographic characteristics,primary diagnosis,preoperative refraction,anterior chamber depth(ACD),white-to-white(WTW)measurement,endothelial cell density(ECD),and axial length.Patients’satisfaction and complaints,and their postoperative refraction,vault depth,and axis alignment with the preoperative target,were reviewed during the postoperative period.Collectively,these data were correlated with symptomatic axis rotation and the need for repositioning,explantation,or exchange due to high or low ICL vaults.RESULTS:Of 813 eyes,27(3.32%),13(1.59%),and 11(1.35%)required ICL repositioning,ICL explantation only without exchange,and ICL explantation with the placement of a new ICL,respectively.The mean follow-up period was 37.5mo.The main cause of explanation or exchange was incorrect WTW measurement in seven(29.17%)eyes,followed by high vault in four(16.56%)eyes.ICL repositioning was required in 27(3.32%)eyes with considerable rotation.Only 2(0.24%)eyes developed cataracts that required ICL removal,and retinal complications were reported in 7(0.86%)eyes.Long-term glaucoma and corneal decompensation were not observed in this cohort.CONCLUSION:With a high safety profile and reversibility,ICL implantation is a good alternative to corneal-based refractive surgery in eyes unsuitable for laser vision correction.The rate of secondary procedures in our study was 6.26%.Old age is a risk factor for secondary surgical interventions in the repositioning group,whereas abnormal vault and toric ICL rotation in the explantation group necessitated subsequent surgical procedures.Overall,ICL implantation demonstrates a good efficacy index and safety profile in patients with diverse refractive errors.展开更多
Blindness affected 45 million people globally in 2021,and moderate to severe vision loss a further 295 million.[1]The most common causes,cataract and uncorrected refractive error,are generally the easiest to treat,and...Blindness affected 45 million people globally in 2021,and moderate to severe vision loss a further 295 million.[1]The most common causes,cataract and uncorrected refractive error,are generally the easiest to treat,and are among the most cost-effective procedures in all of medicine and international development.[1-2]Thus,vision impairment is both extremely common and,in principle,readily manageable.展开更多
AIM:To analyze the two-year visual and refractive outcomes as well as the safety,and efficacy of photorefractive keratectomy(PRK)surgery for myopia.METHODS:In this prospective cohort study,63 eligible patients were re...AIM:To analyze the two-year visual and refractive outcomes as well as the safety,and efficacy of photorefractive keratectomy(PRK)surgery for myopia.METHODS:In this prospective cohort study,63 eligible patients were recruited,including 45 women(71.4%)and 18 men(28.6%).Demographic characteristics along with pre-and post-operative clinical data including visual acuity,refraction,maximum ablation,spherical and cylindrical error,and residual stromal bed(RSB)were evaluated.RESULTS:The mean age of the patients was 35.42±8.16y(range 22 to 55y).The mean spherical and cylindrical error before surgery were-2.23±1.58 D(range-5 to+0.25)and-1.24±0.94 D,respectively(range-3.75 to 0.00).The mean efficacy and safety of PRK surgery at 2y follow-up were 0.98±0.06 and 1.01±0.04 respectively.The lower age was significantly correlated with a higher amount of efficacy index(P<0.001,r=-0.42).Also,the lower amount of preoperative myopia and spherical equivalent(SE)were correlated with a higher safety index(P<0.001,r=-0.44;P<0.001,r=-0.46).CONCLUSION:The two-year efficacy and safety of PRK for the treatment of low myopia is excellent.Younger age and lower amount of refractive error are correlated with higher efficacy and safety indices of the surgery.展开更多
There is limited amount of research on surface plasmon resonance(SPR)sensors with self-referencing capabilities which are based on dielectric gratings.In the short-wavelength range,a metal grating sensor is capable of...There is limited amount of research on surface plasmon resonance(SPR)sensors with self-referencing capabilities which are based on dielectric gratings.In the short-wavelength range,a metal grating sensor is capable of simultaneously measuring liquid refractive index under proposed temperature.A fabricated gold grating is placed on one side of a thin gold film for refractive index measurement,while the other with polydimethylsiloxane(PDMS)is deposited on the other side for temperature measurement.We use finite element analysis to research its sensing characteristics.Due to the high refractive index sensitivity of SPR sensors and thermo-optic coefficient of PDMS,we discovered the maximum spectral sensitivity of the sensor is 564 nm/RIU and-50 pm/℃when the liquid refractive index ranges from 1.30 to 1.40 with temperature ranging from 0℃ to 100℃.Numerical results indicate that there may not be mutual interference between two channels for measuring refractive index and temperature,which reduces the complexity of sensor measurements.展开更多
A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electro...A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electrons in a metal are resonated with photons.The structural parameters are fine-tuned and the sensing performance of the sensor is studied.The results show that the maximum spectral sensitivity reaches 18 000 nm/RIU in the refractive index range of 1.24—1.32,and the maximum resolution is 5.56×10^(-6) RIU.The novel structure with high sensitivity and low refractive index provides a new perspective for fluid density detection.展开更多
AIM:To describe the demographics,clinical characteristics and treatment outcomes of childhood amblyopia in a tertiary eye center in western India.METHODS:This was a retrospective longitudinal hospital-based study of 1...AIM:To describe the demographics,clinical characteristics and treatment outcomes of childhood amblyopia in a tertiary eye center in western India.METHODS:This was a retrospective longitudinal hospital-based study of 1382 children aged≤12y included in the National Institute of OphthalMology AmBlyopia StUdy in Indian Paediatric EyeS(NIMBUS)Study.Data on patient demographics,treatment approach,and best-corrected visual acuity(BCVA)changes were reviewed.RESULTS:The mean age of the study cohort was 4.54±2.46y,with males constituting the majority(55.4%).The cause of amblyopia was refractive error in 73.2%,strabismus in 7.3%,and anisometropia in 6.8%of eyes.The majority of therapies comprised glasses(74.4%),followed by occlusion+glasses(10.3%),occlusion alone(7.3%),and surgery+patching+glasses(5.1%).The mean occlusion time was 2.46±1.14h.After a median follow-up of 10.00(6-85)mo,the mean BCVA significantly improved from 0.85±0.41 to 0.55±0.42 logMAR.Subgroup analysis revealed BCVA gain for all etiologies,including refractive errors(P<0.001),strabismus(P<0.001),cataract(P<0.001),and ptosis(P<0.001).Additionally,eyes with refractive errors showed significantly better BCVA than eyes with cataracts(P<0.001),strabismus(P<0.001)and marginally better BCVA than eyes with ptosis(P<0.05),both at the baseline and final visit.CONCLUSION:Refractive errors are the commonest cause of amblyopia,followed by strabismus and anisometropia.Timely detection,optimal therapy,and periodic follow-up are crucial in bettering visual acuity regardless of the cause.展开更多
AIM:To compare the effects of manipulating light levels versus manipulating the spectral content of short wavelengths(blue light)of ambient lighting on refractive development in young rabbits.METHODS:A total of 32 hea...AIM:To compare the effects of manipulating light levels versus manipulating the spectral content of short wavelengths(blue light)of ambient lighting on refractive development in young rabbits.METHODS:A total of 32 healthy 3-week-old rabbits were randomly assigned to one of the four groups with 8 in each group for 12wk:Control group(NC)under low blue light(output ratio of blue light 1.8%)at low illuminance(341 lx),HI group under low blue light(output ratio of blue light 1.6%)at high illuminance(5057 lx),simulating natural light(S-NL)group under high blue light(output ratio of blue light 4.9%)at high illuminance(5052 lx),and MB group under high blue light(output ratio of blue light 5.2%)at low illuminance(342 lx).The lighting in each group were provided by light emitting diode(LED)lamps emitting visible light(range 380-780 nm)in addition to(or not)LED lamps only emitting short wavelength(range 380-500 nm).Refraction,axial length,and corneal curvature radius were assessed by retinoscopy,ultrasonography and keratometry,respectively.Average data of both eyes for each animal were used as single values and compared among groups.RESULTS:During the 12-week intervention,all animals had an emmetropization period.The decrease of refraction in rabbits in HI group was similar to S-NL group,both slower than that of NC group(P<0.001).At the 12th week,the refraction(3.000±0.267 D)and vitreous cavity depth(7.421±0.168 mm)of S-NL was similar to HI group(3.250±0.267 D,7.264±0.256 mm),significantly different from NC group(1.937±0.291 D,7.825±0.313 mm;P<0.001 for both).High blue light at low illuminance had little effect on refraction change.At the end of intervention,the difference of refraction(2.219±0.281 D)and vitreous cavity depth(7.785±0.229 mm)in MB group were not statistically significant(P=0.311,P=0.749)compared with NC group.The other components were less affected by lighting conditions(P>0.05).CONCLUSION:The light levels per se but not the rich in spectral content of short wavelengths determine the inhibitory effect of ambient lighting on myopia development in rabbits.展开更多
AIM:To compare objective dry retinoscopy and subjective refraction measurements in patients with mild keratoconus(KCN)and quantify any differences.METHODS:This cross-sectional study was done on 68 eyes of 68 patients ...AIM:To compare objective dry retinoscopy and subjective refraction measurements in patients with mild keratoconus(KCN)and quantify any differences.METHODS:This cross-sectional study was done on 68 eyes of 68 patients diagnosed with mild KCN.Objective dry retinoscopy using autorefractometer and subjective refraction measurements were performed.Sphere,cylinder,J0,J45,and spherical equivalent values were compared between the two techniques.RESULTS:The mean age of 68 patients with mild KCN was 21.32±5.03y(12–35y).There were 37(54.4%)males.Objective refraction yielded significantly more myopic sphere(-1.44 D vs-0.57 D),higher cylinder magnitude(-2.24 D vs-1.48 D),and more myopic spherical equivalent(-2.56 D vs-1.31 D)compared to subjective refraction(all P<0.05).The mean differences were-0.87 D for sphere,-0.76 D for cylinder,and-1.25 D for spherical equivalent.No significant differences were found for J0 and J45 values,indicating agreement in astigmatism axis(P>0.05).CONCLUSION:In patients with mild KCN,objective dry retinoscopy overestimates the degree of myopia and astigmatism compared to subjective refraction.The irregular cornea in KCN likely impacts objective measurements.Subjective refraction allows compensation for irregularity,providing a more accurate correction.When determining refractive targets,the tendency of objective methods to overcorrect should be considered.展开更多
AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract s...AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.展开更多
AIM:To determine the diagnostic ability of various visual functions in patients with multiple sclerosis(MS)with and without optic neuritis(ON).METHODS:In this cross-sectional study,we assessed and compared refractive ...AIM:To determine the diagnostic ability of various visual functions in patients with multiple sclerosis(MS)with and without optic neuritis(ON).METHODS:In this cross-sectional study,we assessed and compared refractive error,visual acuity(VA),and contrast sensitivity(CS)between patients with MS and a matched control group of healthy individuals.The MS patients were further categorized into those with ON and those without.RESULTS:A total of 133 eyes from 133 participants were assessed,including 66 individuals diagnosed with MS.The mean ages for the MS group and the healthy control group were 37.5±4.27y and 38.45±4.60y,respectively(P=0.346).Among the 66 patients with MS,18 had ON.The presence of MS was associated with a decrease in best-corrected visual acuity(BCVA)and spherical component of refractive error(P<0.05),whereas ON did not lead to any further decline in these parameters(P>0.05).MS was linked to decreased CS at spatial frequencies of 6 and 18 cycles per degree(CPD;P<0.05),while ON in MS patients resulted in an additional decrease in CS at 3 CPD(P=0.03).The most significant sensitivity for distinguishing MS patients from healthy individuals as well as MS patients with ON from those without ON was found with cylindrical component[associated criterion(AC)>-0.75 D;71.21%]and CS at spatial frequency of 6 CPD(AC≤1.56;72.22%),respectively.Conversely,the highest specificity for these diagnostic measures was associated with BCVA(AC>0 logMAR;97.01%)and CS at a spatial frequency of 12 CPD(AC≤0.60;93.75%),respectively.CONCLUSION:MS significantly affects refractive error and CS,with ON further reducing CS.Assessing these visual parameters can improve MS monitoring and management.展开更多
AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students usin...AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students using simple random sampling.Objective refraction,ocular alignment,vergence and accommodative performance were measured and assessed in all participants.Data on QOL were collected using the College of Optometrists in Vision Development-Quality of Life(COVD-QOL)Questionnaire.The effect of mentioned parameters on the QOL were evaluated.RESULTS:Totally 726 students with mean age of 21.35±1.88y were evaluated in this study,51.5%of whom were female.Esophoria was caused significantly lower QOL in the domains of somatic symptoms and occupationalphysical symptoms(P<0.05);Besides,esotropia decreased QOL in domains of somatic symptoms P=0.002 and psychological factors(P=0.023).Students with accommodation insufficiency experienced more symptoms in all domains(P<0.05)except for psychological factors(P=0.07).Increasing in the near point of convergence and accommodation and decreases QOL and increasing accommodative facility increases QOL(all P<0.05).Myopia and astigmatism cause decrease in QOL(both P<0.05),but hyperopic students had better QOL in comparison with others(P<0.05).CONCLUSION:Screening programs and treatment of refractive errors and binocular vision anomalies,especially phoria and accommodative insufficiency,positively impact the QOL and academic achievements of university students.展开更多
In this paper,we have calculated the structural,electronic,and optical properties of chalcogenide stannite Cu_(2)CdSnX4(X=S,Se,Te) materials.The calculations are based on the density functional theory (DFT) method and...In this paper,we have calculated the structural,electronic,and optical properties of chalcogenide stannite Cu_(2)CdSnX4(X=S,Se,Te) materials.The calculations are based on the density functional theory (DFT) method and are performed using the Cambridge sequential total energy package (CASTEP) code included in the Biovia Material Studio 20 software.All optical properties have been studied in a domain that extends energetically from 10 meV to 40 eV.Our results show that Cu_(2)CdSnX4(X=S,Se,Te) stannite exhibits absorption in the visible region,the refractive index decreases with increasing energy,and the refractive index values are n=3.2,3.73 and 3.75 for Cu_(2)CdSnS_(4),Cu_(2)CdSnSe_(4)and Cu_(2)CdSnTe_(4),respectively.They show also high conductivity,which implies that this material is promising for solar cells.These results argue in favor of the use of these materials in various potential applications.The density of state,band structures,and structural properties of Cu_(2)CdSnX4(X=S,Se,and Te) stannite are also studied in this work.展开更多
To enhance the quality factor and sensitivity of refractive index sensors,a feedback waveguide slot grating micro-ring resonator was proposed.An air-hole grating structure was introduced based on the slot micro-ring,u...To enhance the quality factor and sensitivity of refractive index sensors,a feedback waveguide slot grating micro-ring resonator was proposed.An air-hole grating structure was introduced based on the slot micro-ring,utilizing the reflection of the grating to achieve the electromagnetic-like induced transparency effect at different wavelengths.The high slope characteristics of the EIT-like effect enabled a higher quality factor and sensitivity.The transmission principle of the structure was analyzed using the transmission matrix method,and the transmission spectrum and mode field distribution were simulated using the finite-difference time-domain(FDTD)method,and the device structure parameters were adjusted for optimization.Simulation results show that the proposed structure achieves an EIT-like effect with a quality factor of 59267.5.In the analysis of refractive index sensing characteristics,the structure exhibits a sensitivity of 408.57 nm/RIU and a detection limit of 6.23×10^(-5) RIU.Therefore,the proposed structure achieved both a high quality factor and refractive index sensitivity,demonstrating excellent sensing performance for applications in environmental monitoring,biomedical fields,and other areas with broad market potential.展开更多
AIM:To analyze ocular parameters and refractive status in children aged 3-12y and to explore differences in these parameters across age groups with identical refractive status for studying refractive progression.METHO...AIM:To analyze ocular parameters and refractive status in children aged 3-12y and to explore differences in these parameters across age groups with identical refractive status for studying refractive progression.METHODS:Demographic characteristics,cycloplegic refraction data,and ocular parameters of the participants were collected.Changes in ocular parameters were described according to different age groups.After adjusting for refractive factors,the relationship between age and ocular parameters was explored.Standard regression coefficients(β)obtained from multiple linear regressions were used to compare the magnitude of the effect of age on the parameters and ocular components on refractive power.RESULTS:Data were collected from the right eyes of 1504 participants.Lens thickness(LT)decreased with age,whereas the axial length(AL)and anterior chamber depth(ACD)increased.In the high-hyperopia group,changes in age were only associated with AL and LT.In the low-myopia group,the increase in age was also associated with corneal astigmatism.In the overall model,theβvalue for LT was the highest at 0.41,whereasβfor ACD and AL was significant in all groups except for the high-hyperopia group.Theβvalue of the LT on refractive power in children was slightly greater in the low age group than in the high age group.CONCLUSION:Among children with the same refractive status,the older the age,the longer the axis length and the thinner the lens.The lens affected refractive power in children in the younger age group more than in the older age group.The ocular parameter most affected by age was LT.展开更多
AIM:To report the refractive and surgical outcomes of scleral buckling(SB)with or without pars plana vitrectomy(PPV)in patients with pseudophakic rhegmatogenous retinal detachment(PRRD).METHODS:A consecutive case seri...AIM:To report the refractive and surgical outcomes of scleral buckling(SB)with or without pars plana vitrectomy(PPV)in patients with pseudophakic rhegmatogenous retinal detachment(PRRD).METHODS:A consecutive case series of patients with pseudophakia who underwent retinal detachment(RD)surgery was enrolled.The SB procedures were selected to initially treat primary pseudophakic PRRDs and SB-PPV for more complex cases,according to preoperative findings.Eyes with anterior chamber intraocular lens,proliferative vitreoretinopathy anterior to equator,previous invasive glaucoma surgery,severe degenerative myopia or macular hole,and<6mo follow-up were excluded from outcomes analysis.The primary clinical outcome measures were the single surgery anatomic success(SSAS)and final surgery anatomic success(FSAS)rates.Secondary outcome measures were postoperative visual acuity and refractive error.RESULTS:A total of 81 consecutive patients(81 eyes)were enrolled for analysis,comprising 66(81%)men and 15(19%)women with a mean age of 58y(range,33-86y)and the mean final follow-up period was 21.0±19.6mo.A total of 62 PRRDs(n=62;76.5%)were repaired with an initial SB,and 19 PRRDs(n=19;23.5%)were repaired with a combined SB-PPV.The SSAS and FSAS rates were 92.6%(75/81)and 100%(81/81),respectively.All initial failures had retinal reattachment after the secondary PPV.The mean final postoperative best-corrected visual acuity(BCVA)was 0.42±0.33 logMAR(visual acuity 20/55)and final mean refractive error was-1.48±1.40 diopters.The patients who underwent initially SB-PPV had a significantly longer duration of RD and a higher giant retinal tear rate(P<0.05)preoperatively.SSAS was 56/62(90.3%)and 19/19(100%),and the mean postoperative refractive error was-1.30±1.32 D and-1.53±1.38 D for the patients in the SB and SB-PPV groups,respectively.There was no statistically significant difference for those who had SSAS and postoperative refractive errors between the 2 groups.The postoperative BCVAs of the patients with SSAS were not significantly better in the SB group(median,20/40)than in the SB-PPV group(median 20/50).In the SB group,patients with macula-on had better visual acuity postoperatively than patients with macula-off(P=0.000).CONCLUSION:The initial surgical procedures of SB with or without PPV according to the preoperative findings achieve a high reattachment rate and an acceptable refractive error for primary pseudophakic RRD management.展开更多
Perovskite solar cells(PSCs)have been receiving attention for photovoltaic advantages of high-power conversion efficiency,cost-effectiveness,and easy fabrication process.Particularly,flexible PSCs(FPSCs)are considered...Perovskite solar cells(PSCs)have been receiving attention for photovoltaic advantages of high-power conversion efficiency,cost-effectiveness,and easy fabrication process.Particularly,flexible PSCs(FPSCs)are considered to be promising renewable power sources due to the positive potential of flexible and lightweight properties.However,FPSCs tend to have lower efficiency compared to glass-based rigid PSCs(RPSCs).The main issue is high refractive index of polymer substrates such as polyethylene naphthalate(PEN),used for FPSCs,thereby reducing the external light absorption efficiency.In this study,we developed glasswing inspired sticker-type multilayer anti-reflective(GSMA)film derived from the wings of the glasswing butterfly to enhance the light absorption efficiency of FPSCs.We designed and fabricated the GSMA film with multilayers specifically for FPSCs.The suitable materials and nanostructures to adjust the refractive index are theoretically optimized.The GSMA film effectively improved the optical properties of PSC substrates,reducing reflectance(∼5.01%)and enhancing light transmittance(∼6.17%)in indium tin oxide(ITO)/PEN.In addition,the GSMA film on PEN maintains more than 94.70%of its initial transmittance even after being exposed to various harsh environments for 500 h,and GSMA film demonstrates flexibility by maintaining its initial structure even after a bending test(bending radius of 1 mm).The FPSCs and RPSCs assisted by GSMA film show high short-circuit current density(FPSC:∼25.28 mA/cm^(2),up to 26.05 mA/cm^(2),RPSC:∼24.27 mA/cm^(2))and power conversion efficiency(FPSC:∼22.72%,RPSC:∼22.31%),significantly narrowing the efficiency gap between FPSC and RPSCs.展开更多
AIM:To compare the subjective refraction data with autorefraction findings in high astigmatisms.METHODS:In a cross-sectional study,sampling was done from in different geographic regions in Iran using a multistage rand...AIM:To compare the subjective refraction data with autorefraction findings in high astigmatisms.METHODS:In a cross-sectional study,sampling was done from in different geographic regions in Iran using a multistage random cluster sampling method.All study participants underwent cycloplegic auto-refraction and subjective refraction using the red-green test.RESULTS:In this study,277 eyes of 158 students aged 8 to 15y were analyzed.According to the results,the mean difference between subjective refraction and autorefraction in measuring sphere,cylinder,spherical equivalent,J0,and J45 was-0.18±0.76,-0.36±0.40,-0.36±0.79,0.15±0.20,and 0.05±0.21 respectively.The correlation of these two refraction methods in measuring the aforementioned indices was 0.963,0.898,0.960,0.931,and 0.948 respectively.The 95%limits of agreement of the two methods in measuring the above indices were-1.66 to 1.31,-1.14 to 0.42,-1.91 to 1.19,-0.24 to 0.54,and-0.36 to 0.47 respectively.The agreement between the two methods decreased with increasing cylinder power,and the best agreement was found in myopic individuals.CONCLUSION:The measurements obtained by autorefractometer have a significantly higher cylinder average compared to subjective refraction.However,in the cylinder range of 4–5 diopters,the values of J0 and J45 do not have a high correlation.展开更多
Magmatism at continental margins is of great significance in understanding the continental rifting.We present a twodimensional P-wave velocity model derived from an ocean bottom seismometer experiment,conducted across...Magmatism at continental margins is of great significance in understanding the continental rifting.We present a twodimensional P-wave velocity model derived from an ocean bottom seismometer experiment,conducted across the middle northern continental margin of the South China Sea(SCS).The detailed velocity structures reveal significant heterogeneities extending from the continental shelf to the continent-ocean transition zone.The crust exhibits its greatest thickness below the continental shelf,measuring~23 km and gradually thins to~13 km at the distal margin.Furthermore,a narrow and distinct continent-ocean transition with only 40-km width is revealed.We also observe a high-velocity layer within the transition zone,reaching thickness of up to 4 km,characterized by P-wave velocities ranging from 7.0 km/s to 7.6 km/s in the lower crust.Based on the syn-rift melt generation using decompression melting model,we ascertain that syn-rift magmatism cannot fully account for the observed thick high-velocity layer.By integrating findings from previous geophysical and geochemical studies presenting extensive volcanic edifice on the seafloor at the northern margin,as well as ocean-island-basalt-type magmaticsamples in the SCS area,we propose that post-rifting magmatism associated with the Hainan Plume may have influenced theformation of the high-velocity lower crust within the transition zone and the northern margin of the SCS can thus be recognizedas magma-poor type margin.展开更多
文摘An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The analytic solution is obtained by asymptotic approximation of a Fourier field integral under the condition of great beam width in comparison with a wavelength (the geometrical-optics approximation). This model can be used also for approximate simulation of refracted field in the cases of beam incidence near the critical angle on transparent or absorbing (amplifying) refracting medium, if one artificially introduces the additional absorption (amplification), whose value is proportional to the ratio of the wavelength and the effective beam width. It is shown that the analytic model reflects the general features of refracted field at total internal reflection.
基金Supported by the "10th Five-Year" National Science and Technology Plan of China (Grant No.2003BA613A-09)China Innovation Foundation of Petroleum Technology for Young and Middle-Aged Scholars (Grant No.03E7018)
文摘Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration. In three-component seismic exploration data processing,one of the difficulties is static correction of converted wave. This paper analyzes propagation characteristics of non-converted and converted refracted waves,and discovers a favor-able condition for the formation of converted refracted wave,i.e. the velocity of overlaying medium S wave is much lower than that of underlying medium S wave. In addition,the paper proposes the static correction method of converted wave based on PPS converted refracted wave,and processes the real three-component seismic data with better results of static correction of converted wave.
文摘AIM:To evaluate the visual outcomes of implantable collamer lenses(ICLs)and identify the possible risk factors for ICL axis misalignment,and consequently,repositioning,explanting,or exchanging at a specialized eye hospital in Saudi Arabia.METHODS:The medical records of 813 eyes with different refractive errors corrected with ICL implantation were identified and included in this single-arm retrospective cohort study.The following data were collected:demographic characteristics,primary diagnosis,preoperative refraction,anterior chamber depth(ACD),white-to-white(WTW)measurement,endothelial cell density(ECD),and axial length.Patients’satisfaction and complaints,and their postoperative refraction,vault depth,and axis alignment with the preoperative target,were reviewed during the postoperative period.Collectively,these data were correlated with symptomatic axis rotation and the need for repositioning,explantation,or exchange due to high or low ICL vaults.RESULTS:Of 813 eyes,27(3.32%),13(1.59%),and 11(1.35%)required ICL repositioning,ICL explantation only without exchange,and ICL explantation with the placement of a new ICL,respectively.The mean follow-up period was 37.5mo.The main cause of explanation or exchange was incorrect WTW measurement in seven(29.17%)eyes,followed by high vault in four(16.56%)eyes.ICL repositioning was required in 27(3.32%)eyes with considerable rotation.Only 2(0.24%)eyes developed cataracts that required ICL removal,and retinal complications were reported in 7(0.86%)eyes.Long-term glaucoma and corneal decompensation were not observed in this cohort.CONCLUSION:With a high safety profile and reversibility,ICL implantation is a good alternative to corneal-based refractive surgery in eyes unsuitable for laser vision correction.The rate of secondary procedures in our study was 6.26%.Old age is a risk factor for secondary surgical interventions in the repositioning group,whereas abnormal vault and toric ICL rotation in the explantation group necessitated subsequent surgical procedures.Overall,ICL implantation demonstrates a good efficacy index and safety profile in patients with diverse refractive errors.
文摘Blindness affected 45 million people globally in 2021,and moderate to severe vision loss a further 295 million.[1]The most common causes,cataract and uncorrected refractive error,are generally the easiest to treat,and are among the most cost-effective procedures in all of medicine and international development.[1-2]Thus,vision impairment is both extremely common and,in principle,readily manageable.
文摘AIM:To analyze the two-year visual and refractive outcomes as well as the safety,and efficacy of photorefractive keratectomy(PRK)surgery for myopia.METHODS:In this prospective cohort study,63 eligible patients were recruited,including 45 women(71.4%)and 18 men(28.6%).Demographic characteristics along with pre-and post-operative clinical data including visual acuity,refraction,maximum ablation,spherical and cylindrical error,and residual stromal bed(RSB)were evaluated.RESULTS:The mean age of the patients was 35.42±8.16y(range 22 to 55y).The mean spherical and cylindrical error before surgery were-2.23±1.58 D(range-5 to+0.25)and-1.24±0.94 D,respectively(range-3.75 to 0.00).The mean efficacy and safety of PRK surgery at 2y follow-up were 0.98±0.06 and 1.01±0.04 respectively.The lower age was significantly correlated with a higher amount of efficacy index(P<0.001,r=-0.42).Also,the lower amount of preoperative myopia and spherical equivalent(SE)were correlated with a higher safety index(P<0.001,r=-0.44;P<0.001,r=-0.46).CONCLUSION:The two-year efficacy and safety of PRK for the treatment of low myopia is excellent.Younger age and lower amount of refractive error are correlated with higher efficacy and safety indices of the surgery.
基金supported by the National Natural Science Foundation of China(No.52276094)the Education Project of Hunan Provincial Department(Nos.20B602 and 22C0112)+2 种基金the Industry University Education Cooperation Project(No.230803117185211)the Research Project on Teaching Reform in Ordinary Undergraduate Universities in Hunan Province(No.202401000142)the Natural Science Foundation of Hunan Province(No.2020JJ4935)。
文摘There is limited amount of research on surface plasmon resonance(SPR)sensors with self-referencing capabilities which are based on dielectric gratings.In the short-wavelength range,a metal grating sensor is capable of simultaneously measuring liquid refractive index under proposed temperature.A fabricated gold grating is placed on one side of a thin gold film for refractive index measurement,while the other with polydimethylsiloxane(PDMS)is deposited on the other side for temperature measurement.We use finite element analysis to research its sensing characteristics.Due to the high refractive index sensitivity of SPR sensors and thermo-optic coefficient of PDMS,we discovered the maximum spectral sensitivity of the sensor is 564 nm/RIU and-50 pm/℃when the liquid refractive index ranges from 1.30 to 1.40 with temperature ranging from 0℃ to 100℃.Numerical results indicate that there may not be mutual interference between two channels for measuring refractive index and temperature,which reduces the complexity of sensor measurements.
基金supported by the Natural Science Foundation of Tianjin City (No.19JCYBJC17000)the National Natural Science Foundation of China (No.11905159)。
文摘A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electrons in a metal are resonated with photons.The structural parameters are fine-tuned and the sensing performance of the sensor is studied.The results show that the maximum spectral sensitivity reaches 18 000 nm/RIU in the refractive index range of 1.24—1.32,and the maximum resolution is 5.56×10^(-6) RIU.The novel structure with high sensitivity and low refractive index provides a new perspective for fluid density detection.
文摘AIM:To describe the demographics,clinical characteristics and treatment outcomes of childhood amblyopia in a tertiary eye center in western India.METHODS:This was a retrospective longitudinal hospital-based study of 1382 children aged≤12y included in the National Institute of OphthalMology AmBlyopia StUdy in Indian Paediatric EyeS(NIMBUS)Study.Data on patient demographics,treatment approach,and best-corrected visual acuity(BCVA)changes were reviewed.RESULTS:The mean age of the study cohort was 4.54±2.46y,with males constituting the majority(55.4%).The cause of amblyopia was refractive error in 73.2%,strabismus in 7.3%,and anisometropia in 6.8%of eyes.The majority of therapies comprised glasses(74.4%),followed by occlusion+glasses(10.3%),occlusion alone(7.3%),and surgery+patching+glasses(5.1%).The mean occlusion time was 2.46±1.14h.After a median follow-up of 10.00(6-85)mo,the mean BCVA significantly improved from 0.85±0.41 to 0.55±0.42 logMAR.Subgroup analysis revealed BCVA gain for all etiologies,including refractive errors(P<0.001),strabismus(P<0.001),cataract(P<0.001),and ptosis(P<0.001).Additionally,eyes with refractive errors showed significantly better BCVA than eyes with cataracts(P<0.001),strabismus(P<0.001)and marginally better BCVA than eyes with ptosis(P<0.05),both at the baseline and final visit.CONCLUSION:Refractive errors are the commonest cause of amblyopia,followed by strabismus and anisometropia.Timely detection,optimal therapy,and periodic follow-up are crucial in bettering visual acuity regardless of the cause.
基金Supported by Natural Science Foundation of Sichuan Province(No.2022NSFSC0754)Project of Nanchong Science and Technology Bureau(No.22SXQT0350).
文摘AIM:To compare the effects of manipulating light levels versus manipulating the spectral content of short wavelengths(blue light)of ambient lighting on refractive development in young rabbits.METHODS:A total of 32 healthy 3-week-old rabbits were randomly assigned to one of the four groups with 8 in each group for 12wk:Control group(NC)under low blue light(output ratio of blue light 1.8%)at low illuminance(341 lx),HI group under low blue light(output ratio of blue light 1.6%)at high illuminance(5057 lx),simulating natural light(S-NL)group under high blue light(output ratio of blue light 4.9%)at high illuminance(5052 lx),and MB group under high blue light(output ratio of blue light 5.2%)at low illuminance(342 lx).The lighting in each group were provided by light emitting diode(LED)lamps emitting visible light(range 380-780 nm)in addition to(or not)LED lamps only emitting short wavelength(range 380-500 nm).Refraction,axial length,and corneal curvature radius were assessed by retinoscopy,ultrasonography and keratometry,respectively.Average data of both eyes for each animal were used as single values and compared among groups.RESULTS:During the 12-week intervention,all animals had an emmetropization period.The decrease of refraction in rabbits in HI group was similar to S-NL group,both slower than that of NC group(P<0.001).At the 12th week,the refraction(3.000±0.267 D)and vitreous cavity depth(7.421±0.168 mm)of S-NL was similar to HI group(3.250±0.267 D,7.264±0.256 mm),significantly different from NC group(1.937±0.291 D,7.825±0.313 mm;P<0.001 for both).High blue light at low illuminance had little effect on refraction change.At the end of intervention,the difference of refraction(2.219±0.281 D)and vitreous cavity depth(7.785±0.229 mm)in MB group were not statistically significant(P=0.311,P=0.749)compared with NC group.The other components were less affected by lighting conditions(P>0.05).CONCLUSION:The light levels per se but not the rich in spectral content of short wavelengths determine the inhibitory effect of ambient lighting on myopia development in rabbits.
文摘AIM:To compare objective dry retinoscopy and subjective refraction measurements in patients with mild keratoconus(KCN)and quantify any differences.METHODS:This cross-sectional study was done on 68 eyes of 68 patients diagnosed with mild KCN.Objective dry retinoscopy using autorefractometer and subjective refraction measurements were performed.Sphere,cylinder,J0,J45,and spherical equivalent values were compared between the two techniques.RESULTS:The mean age of 68 patients with mild KCN was 21.32±5.03y(12–35y).There were 37(54.4%)males.Objective refraction yielded significantly more myopic sphere(-1.44 D vs-0.57 D),higher cylinder magnitude(-2.24 D vs-1.48 D),and more myopic spherical equivalent(-2.56 D vs-1.31 D)compared to subjective refraction(all P<0.05).The mean differences were-0.87 D for sphere,-0.76 D for cylinder,and-1.25 D for spherical equivalent.No significant differences were found for J0 and J45 values,indicating agreement in astigmatism axis(P>0.05).CONCLUSION:In patients with mild KCN,objective dry retinoscopy overestimates the degree of myopia and astigmatism compared to subjective refraction.The irregular cornea in KCN likely impacts objective measurements.Subjective refraction allows compensation for irregularity,providing a more accurate correction.When determining refractive targets,the tendency of objective methods to overcorrect should be considered.
文摘AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.
文摘AIM:To determine the diagnostic ability of various visual functions in patients with multiple sclerosis(MS)with and without optic neuritis(ON).METHODS:In this cross-sectional study,we assessed and compared refractive error,visual acuity(VA),and contrast sensitivity(CS)between patients with MS and a matched control group of healthy individuals.The MS patients were further categorized into those with ON and those without.RESULTS:A total of 133 eyes from 133 participants were assessed,including 66 individuals diagnosed with MS.The mean ages for the MS group and the healthy control group were 37.5±4.27y and 38.45±4.60y,respectively(P=0.346).Among the 66 patients with MS,18 had ON.The presence of MS was associated with a decrease in best-corrected visual acuity(BCVA)and spherical component of refractive error(P<0.05),whereas ON did not lead to any further decline in these parameters(P>0.05).MS was linked to decreased CS at spatial frequencies of 6 and 18 cycles per degree(CPD;P<0.05),while ON in MS patients resulted in an additional decrease in CS at 3 CPD(P=0.03).The most significant sensitivity for distinguishing MS patients from healthy individuals as well as MS patients with ON from those without ON was found with cylindrical component[associated criterion(AC)>-0.75 D;71.21%]and CS at spatial frequency of 6 CPD(AC≤1.56;72.22%),respectively.Conversely,the highest specificity for these diagnostic measures was associated with BCVA(AC>0 logMAR;97.01%)and CS at a spatial frequency of 12 CPD(AC≤0.60;93.75%),respectively.CONCLUSION:MS significantly affects refractive error and CS,with ON further reducing CS.Assessing these visual parameters can improve MS monitoring and management.
文摘AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students using simple random sampling.Objective refraction,ocular alignment,vergence and accommodative performance were measured and assessed in all participants.Data on QOL were collected using the College of Optometrists in Vision Development-Quality of Life(COVD-QOL)Questionnaire.The effect of mentioned parameters on the QOL were evaluated.RESULTS:Totally 726 students with mean age of 21.35±1.88y were evaluated in this study,51.5%of whom were female.Esophoria was caused significantly lower QOL in the domains of somatic symptoms and occupationalphysical symptoms(P<0.05);Besides,esotropia decreased QOL in domains of somatic symptoms P=0.002 and psychological factors(P=0.023).Students with accommodation insufficiency experienced more symptoms in all domains(P<0.05)except for psychological factors(P=0.07).Increasing in the near point of convergence and accommodation and decreases QOL and increasing accommodative facility increases QOL(all P<0.05).Myopia and astigmatism cause decrease in QOL(both P<0.05),but hyperopic students had better QOL in comparison with others(P<0.05).CONCLUSION:Screening programs and treatment of refractive errors and binocular vision anomalies,especially phoria and accommodative insufficiency,positively impact the QOL and academic achievements of university students.
基金supported by the University Sultan Moulay Slimane,Beni Mellal,Morocco。
文摘In this paper,we have calculated the structural,electronic,and optical properties of chalcogenide stannite Cu_(2)CdSnX4(X=S,Se,Te) materials.The calculations are based on the density functional theory (DFT) method and are performed using the Cambridge sequential total energy package (CASTEP) code included in the Biovia Material Studio 20 software.All optical properties have been studied in a domain that extends energetically from 10 meV to 40 eV.Our results show that Cu_(2)CdSnX4(X=S,Se,Te) stannite exhibits absorption in the visible region,the refractive index decreases with increasing energy,and the refractive index values are n=3.2,3.73 and 3.75 for Cu_(2)CdSnS_(4),Cu_(2)CdSnSe_(4)and Cu_(2)CdSnTe_(4),respectively.They show also high conductivity,which implies that this material is promising for solar cells.These results argue in favor of the use of these materials in various potential applications.The density of state,band structures,and structural properties of Cu_(2)CdSnX4(X=S,Se,and Te) stannite are also studied in this work.
基金supported by Natural Science Foundation of Gansu Province(NO.21JR7RA289)。
文摘To enhance the quality factor and sensitivity of refractive index sensors,a feedback waveguide slot grating micro-ring resonator was proposed.An air-hole grating structure was introduced based on the slot micro-ring,utilizing the reflection of the grating to achieve the electromagnetic-like induced transparency effect at different wavelengths.The high slope characteristics of the EIT-like effect enabled a higher quality factor and sensitivity.The transmission principle of the structure was analyzed using the transmission matrix method,and the transmission spectrum and mode field distribution were simulated using the finite-difference time-domain(FDTD)method,and the device structure parameters were adjusted for optimization.Simulation results show that the proposed structure achieves an EIT-like effect with a quality factor of 59267.5.In the analysis of refractive index sensing characteristics,the structure exhibits a sensitivity of 408.57 nm/RIU and a detection limit of 6.23×10^(-5) RIU.Therefore,the proposed structure achieved both a high quality factor and refractive index sensitivity,demonstrating excellent sensing performance for applications in environmental monitoring,biomedical fields,and other areas with broad market potential.
基金Supported by the National Natural Science Foundation of China(No.82171093).
文摘AIM:To analyze ocular parameters and refractive status in children aged 3-12y and to explore differences in these parameters across age groups with identical refractive status for studying refractive progression.METHODS:Demographic characteristics,cycloplegic refraction data,and ocular parameters of the participants were collected.Changes in ocular parameters were described according to different age groups.After adjusting for refractive factors,the relationship between age and ocular parameters was explored.Standard regression coefficients(β)obtained from multiple linear regressions were used to compare the magnitude of the effect of age on the parameters and ocular components on refractive power.RESULTS:Data were collected from the right eyes of 1504 participants.Lens thickness(LT)decreased with age,whereas the axial length(AL)and anterior chamber depth(ACD)increased.In the high-hyperopia group,changes in age were only associated with AL and LT.In the low-myopia group,the increase in age was also associated with corneal astigmatism.In the overall model,theβvalue for LT was the highest at 0.41,whereasβfor ACD and AL was significant in all groups except for the high-hyperopia group.Theβvalue of the LT on refractive power in children was slightly greater in the low age group than in the high age group.CONCLUSION:Among children with the same refractive status,the older the age,the longer the axis length and the thinner the lens.The lens affected refractive power in children in the younger age group more than in the older age group.The ocular parameter most affected by age was LT.
文摘AIM:To report the refractive and surgical outcomes of scleral buckling(SB)with or without pars plana vitrectomy(PPV)in patients with pseudophakic rhegmatogenous retinal detachment(PRRD).METHODS:A consecutive case series of patients with pseudophakia who underwent retinal detachment(RD)surgery was enrolled.The SB procedures were selected to initially treat primary pseudophakic PRRDs and SB-PPV for more complex cases,according to preoperative findings.Eyes with anterior chamber intraocular lens,proliferative vitreoretinopathy anterior to equator,previous invasive glaucoma surgery,severe degenerative myopia or macular hole,and<6mo follow-up were excluded from outcomes analysis.The primary clinical outcome measures were the single surgery anatomic success(SSAS)and final surgery anatomic success(FSAS)rates.Secondary outcome measures were postoperative visual acuity and refractive error.RESULTS:A total of 81 consecutive patients(81 eyes)were enrolled for analysis,comprising 66(81%)men and 15(19%)women with a mean age of 58y(range,33-86y)and the mean final follow-up period was 21.0±19.6mo.A total of 62 PRRDs(n=62;76.5%)were repaired with an initial SB,and 19 PRRDs(n=19;23.5%)were repaired with a combined SB-PPV.The SSAS and FSAS rates were 92.6%(75/81)and 100%(81/81),respectively.All initial failures had retinal reattachment after the secondary PPV.The mean final postoperative best-corrected visual acuity(BCVA)was 0.42±0.33 logMAR(visual acuity 20/55)and final mean refractive error was-1.48±1.40 diopters.The patients who underwent initially SB-PPV had a significantly longer duration of RD and a higher giant retinal tear rate(P<0.05)preoperatively.SSAS was 56/62(90.3%)and 19/19(100%),and the mean postoperative refractive error was-1.30±1.32 D and-1.53±1.38 D for the patients in the SB and SB-PPV groups,respectively.There was no statistically significant difference for those who had SSAS and postoperative refractive errors between the 2 groups.The postoperative BCVAs of the patients with SSAS were not significantly better in the SB group(median,20/40)than in the SB-PPV group(median 20/50).In the SB group,patients with macula-on had better visual acuity postoperatively than patients with macula-off(P=0.000).CONCLUSION:The initial surgical procedures of SB with or without PPV according to the preoperative findings achieve a high reattachment rate and an acceptable refractive error for primary pseudophakic RRD management.
基金supported by the Basic Science Research Program through the National Research Foundation of Korea(NRF)funded by the Ministry of Education(2020R1I1A3054824)supported by the Nano&Material Technology Development Program(RS-2023-00282896)through the National Research Foundation of Korea(NRF)funded by Ministry of Science and ICT。
文摘Perovskite solar cells(PSCs)have been receiving attention for photovoltaic advantages of high-power conversion efficiency,cost-effectiveness,and easy fabrication process.Particularly,flexible PSCs(FPSCs)are considered to be promising renewable power sources due to the positive potential of flexible and lightweight properties.However,FPSCs tend to have lower efficiency compared to glass-based rigid PSCs(RPSCs).The main issue is high refractive index of polymer substrates such as polyethylene naphthalate(PEN),used for FPSCs,thereby reducing the external light absorption efficiency.In this study,we developed glasswing inspired sticker-type multilayer anti-reflective(GSMA)film derived from the wings of the glasswing butterfly to enhance the light absorption efficiency of FPSCs.We designed and fabricated the GSMA film with multilayers specifically for FPSCs.The suitable materials and nanostructures to adjust the refractive index are theoretically optimized.The GSMA film effectively improved the optical properties of PSC substrates,reducing reflectance(∼5.01%)and enhancing light transmittance(∼6.17%)in indium tin oxide(ITO)/PEN.In addition,the GSMA film on PEN maintains more than 94.70%of its initial transmittance even after being exposed to various harsh environments for 500 h,and GSMA film demonstrates flexibility by maintaining its initial structure even after a bending test(bending radius of 1 mm).The FPSCs and RPSCs assisted by GSMA film show high short-circuit current density(FPSC:∼25.28 mA/cm^(2),up to 26.05 mA/cm^(2),RPSC:∼24.27 mA/cm^(2))and power conversion efficiency(FPSC:∼22.72%,RPSC:∼22.31%),significantly narrowing the efficiency gap between FPSC and RPSCs.
基金Supported by Shahid Beheshti University of Medical Sciences.
文摘AIM:To compare the subjective refraction data with autorefraction findings in high astigmatisms.METHODS:In a cross-sectional study,sampling was done from in different geographic regions in Iran using a multistage random cluster sampling method.All study participants underwent cycloplegic auto-refraction and subjective refraction using the red-green test.RESULTS:In this study,277 eyes of 158 students aged 8 to 15y were analyzed.According to the results,the mean difference between subjective refraction and autorefraction in measuring sphere,cylinder,spherical equivalent,J0,and J45 was-0.18±0.76,-0.36±0.40,-0.36±0.79,0.15±0.20,and 0.05±0.21 respectively.The correlation of these two refraction methods in measuring the aforementioned indices was 0.963,0.898,0.960,0.931,and 0.948 respectively.The 95%limits of agreement of the two methods in measuring the above indices were-1.66 to 1.31,-1.14 to 0.42,-1.91 to 1.19,-0.24 to 0.54,and-0.36 to 0.47 respectively.The agreement between the two methods decreased with increasing cylinder power,and the best agreement was found in myopic individuals.CONCLUSION:The measurements obtained by autorefractometer have a significantly higher cylinder average compared to subjective refraction.However,in the cylinder range of 4–5 diopters,the values of J0 and J45 do not have a high correlation.
基金supported by the Guangdong Pearl River Talent Program(No.017TZ07Z066)the Second Tibetan Plateau Scientific Expedition and Research Program(No.2019QZKK0701)+4 种基金the Southern Marine Laboratory(Zhuhai)Innovative R&D Program(No.311021003)the National Natural Science Foundation of China(No.42106067)the Natural Science Foundation of Guangdong Province,China(No.2022A1515010090)Shanghai Sheshan National Geophysical Observatory(No.SSOP202102)Guangzhou Science and Technology Planning Project(No.202102020456).
文摘Magmatism at continental margins is of great significance in understanding the continental rifting.We present a twodimensional P-wave velocity model derived from an ocean bottom seismometer experiment,conducted across the middle northern continental margin of the South China Sea(SCS).The detailed velocity structures reveal significant heterogeneities extending from the continental shelf to the continent-ocean transition zone.The crust exhibits its greatest thickness below the continental shelf,measuring~23 km and gradually thins to~13 km at the distal margin.Furthermore,a narrow and distinct continent-ocean transition with only 40-km width is revealed.We also observe a high-velocity layer within the transition zone,reaching thickness of up to 4 km,characterized by P-wave velocities ranging from 7.0 km/s to 7.6 km/s in the lower crust.Based on the syn-rift melt generation using decompression melting model,we ascertain that syn-rift magmatism cannot fully account for the observed thick high-velocity layer.By integrating findings from previous geophysical and geochemical studies presenting extensive volcanic edifice on the seafloor at the northern margin,as well as ocean-island-basalt-type magmaticsamples in the SCS area,we propose that post-rifting magmatism associated with the Hainan Plume may have influenced theformation of the high-velocity lower crust within the transition zone and the northern margin of the SCS can thus be recognizedas magma-poor type margin.