The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leadi...The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance.展开更多
In this study,Computational Fluid Dynamics(CFD)together with a component transport model are exploited to investigate the influence of dimensionless parameters,involving the height of the rectifier grid and the instal...In this study,Computational Fluid Dynamics(CFD)together with a component transport model are exploited to investigate the influence of dimensionless parameters,involving the height of the rectifier grid and the installation height of the first catalyst layer,on the flow field and the overall denitration efficiency of a cement kiln’s SCR(Selective catalytic reduction)denitrification reactor.It is shown that accurate numerical results can be obtained by fitting the particle size distribution function to the actual cement kiln fly ash and implementing a non-uniform particle inlet boundary condition.The relative error between denitration efficiency derived from experimental data,numerical simulation,and real-time system pressure drop ranges from 4%to 9%.Optimization of the SCR reactor is achieved when the rectifier grid thickness ratio k/H≥0.030,the rectifier grid height ratio h/H=0.04,and the spacing between the rectifier grid and the first catalyst layer l/H=0.10.Under these conditions,airflow distribution and particle dispersion upstream of the catalyst result in increased denitration efficiencies of 3.21%,3.43%,and 3.27%,respectively,compared to the least favorable operating conditions.展开更多
The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main ma...The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main machine is installed in the rotor part,the measurement of the field current in this brushless system seem impossible.Considering that,the field current might be affected by the rectifier mode,the field current estimation method in different rectifier mode is studied in this paper.The main exciter(ME)rotor currents were restructured based on the ME flux equations.With these restructured rotor currents,the field current in different rectifier commutation mode is analyzed,then the field current estimation method considering the rectifier mode can be obtained.The experiments in different rectifier modes are carried out to verify the proposed method.展开更多
The face velocities of the high efficiency particulate air filters and the ultra low penetration airfilters in fan filter units (FFUs) have large relative standard deviation and turbulivity. It seriously affects the ...The face velocities of the high efficiency particulate air filters and the ultra low penetration airfilters in fan filter units (FFUs) have large relative standard deviation and turbulivity. It seriously affects the unidirectivity of the flow in the unidirectional flow clean zone and cleanroom. The cross contamination in this kind of unidirectional flow area is hardly controlled. It is significant to find optional method for keeping the face velocity uniformity of FFU and reducing the face velocity turbulivity of FFU, furthermore, to keep the cleanliness level under FFUs. The normal and easy method is to add flow rectifiers under filters. FFUs with various flow rectifiers have been tested. The uniformity and turbulivity of facevelocity under the FFU are presented in this paper. The influence of the facevelocity uniformity and turbulivity on the contamination boundary of the unidirectional flow is studiedas well.展开更多
文摘The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance.
基金Anhui Province Key Research and Development Plan of the Ecological Environment Project(No.202104i07020016).
文摘In this study,Computational Fluid Dynamics(CFD)together with a component transport model are exploited to investigate the influence of dimensionless parameters,involving the height of the rectifier grid and the installation height of the first catalyst layer,on the flow field and the overall denitration efficiency of a cement kiln’s SCR(Selective catalytic reduction)denitrification reactor.It is shown that accurate numerical results can be obtained by fitting the particle size distribution function to the actual cement kiln fly ash and implementing a non-uniform particle inlet boundary condition.The relative error between denitration efficiency derived from experimental data,numerical simulation,and real-time system pressure drop ranges from 4%to 9%.Optimization of the SCR reactor is achieved when the rectifier grid thickness ratio k/H≥0.030,the rectifier grid height ratio h/H=0.04,and the spacing between the rectifier grid and the first catalyst layer l/H=0.10.Under these conditions,airflow distribution and particle dispersion upstream of the catalyst result in increased denitration efficiencies of 3.21%,3.43%,and 3.27%,respectively,compared to the least favorable operating conditions.
基金supported in part by the Natural Science Foundation of Shaanxi Province under Grant 2023JCQN0534in part by the Natural Science Foundation of Shaanxi Provincial Department of Education under Grant 23JK0660in part by the Xi’an Municipal Bureau of Science and Technology under Grant 24GXF0085。
文摘The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main machine is installed in the rotor part,the measurement of the field current in this brushless system seem impossible.Considering that,the field current might be affected by the rectifier mode,the field current estimation method in different rectifier mode is studied in this paper.The main exciter(ME)rotor currents were restructured based on the ME flux equations.With these restructured rotor currents,the field current in different rectifier commutation mode is analyzed,then the field current estimation method considering the rectifier mode can be obtained.The experiments in different rectifier modes are carried out to verify the proposed method.
文摘The face velocities of the high efficiency particulate air filters and the ultra low penetration airfilters in fan filter units (FFUs) have large relative standard deviation and turbulivity. It seriously affects the unidirectivity of the flow in the unidirectional flow clean zone and cleanroom. The cross contamination in this kind of unidirectional flow area is hardly controlled. It is significant to find optional method for keeping the face velocity uniformity of FFU and reducing the face velocity turbulivity of FFU, furthermore, to keep the cleanliness level under FFUs. The normal and easy method is to add flow rectifiers under filters. FFUs with various flow rectifiers have been tested. The uniformity and turbulivity of facevelocity under the FFU are presented in this paper. The influence of the facevelocity uniformity and turbulivity on the contamination boundary of the unidirectional flow is studiedas well.