The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leadi...The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance.展开更多
In this study,Computational Fluid Dynamics(CFD)together with a component transport model are exploited to investigate the influence of dimensionless parameters,involving the height of the rectifier grid and the instal...In this study,Computational Fluid Dynamics(CFD)together with a component transport model are exploited to investigate the influence of dimensionless parameters,involving the height of the rectifier grid and the installation height of the first catalyst layer,on the flow field and the overall denitration efficiency of a cement kiln’s SCR(Selective catalytic reduction)denitrification reactor.It is shown that accurate numerical results can be obtained by fitting the particle size distribution function to the actual cement kiln fly ash and implementing a non-uniform particle inlet boundary condition.The relative error between denitration efficiency derived from experimental data,numerical simulation,and real-time system pressure drop ranges from 4%to 9%.Optimization of the SCR reactor is achieved when the rectifier grid thickness ratio k/H≥0.030,the rectifier grid height ratio h/H=0.04,and the spacing between the rectifier grid and the first catalyst layer l/H=0.10.Under these conditions,airflow distribution and particle dispersion upstream of the catalyst result in increased denitration efficiencies of 3.21%,3.43%,and 3.27%,respectively,compared to the least favorable operating conditions.展开更多
This paper proposes a double epi-layers 4H-SiC junction barrier Schottky rectifier (JBSR) with embedded P layer (EPL) in the drift region. The structure is characterized by the P-type layer formed in the n-type dr...This paper proposes a double epi-layers 4H-SiC junction barrier Schottky rectifier (JBSR) with embedded P layer (EPL) in the drift region. The structure is characterized by the P-type layer formed in the n-type drift layer by epitaxial overgrowth process. The electric field and potential distribution are changed due to the buried P-layer, resulting in a high breakdown voltage (BV) and low specific on-resistance (Ron,sp). The influences of device parameters, such as the depth of the embedded P+ regions, the space between them and the doping concentration of the drift region, etc., on BV and Ron,sp are investigated by simulations, which provides a particularly useful guideline for the optimal design of the device. The results indicate that BV is increased by 48.5% and Baliga's figure of merit (BFOM) is increased by 67.9% compared to a conventional 4H-SiC JBSR.展开更多
This paper presents a cascode configuration synchronous rectifier device based on silicon MOSFET and Schottky diode,which can replace traditional power diode directly.This structure has self-driven ability with simple...This paper presents a cascode configuration synchronous rectifier device based on silicon MOSFET and Schottky diode,which can replace traditional power diode directly.This structure has self-driven ability with simple external circuit,and the conduction characteristic is preferable to a power diode.Static characterization and switching behavior analysis of proposed structure are conducted in this paper.The switching process is illustrated in detail using real model which considers the parasitic inductances and the nonlinearity of junction capacitors.The real time internal voltage and current value during switching transition are deduced with the equivalent circuit.To validate the analysis,two voltage specification rectifiers are built.Finally,double-pulse test results and the practical design example verify the performance advantages of proposed structure.展开更多
基于二极管整流器的高压直流DR-HVDC(diode-rectifer-based high voltage direct current)输电系统是一种很有前景的海上风电低成本接入方案,它可将风能从偏远的海上风电场输送到陆上电力系统。然而随着海上DR-HVDC系统的不断增多,可能...基于二极管整流器的高压直流DR-HVDC(diode-rectifer-based high voltage direct current)输电系统是一种很有前景的海上风电低成本接入方案,它可将风能从偏远的海上风电场输送到陆上电力系统。然而随着海上DR-HVDC系统的不断增多,可能会导致风机WT(wind turbine)的变流器控制难度增大,系统稳定性变差。基于此,提出了一种适用于DR-HVDC连接海上WT变流器的新型电网形成控制方法。该方法采用2个正序控制回路来调节WTs的输出有功功率,并维持海上交流电网的频率和电压,其中第一个控制器可将每台WT的有功功率误差调节为电压角偏差,从而造成系统频率偏差;第二个控制器通过调整WT的交流电压幅值以抵消频率偏差。变流器内部电流控制回路用于限制故障电流,并消除系统中的高频谐振。最后,通过故障穿越、WT功率变化、无功扰动和WTs停机4个方面的电磁暂态仿真,验证了所提控制方法的有效性和优越性。展开更多
The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main ma...The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main machine is installed in the rotor part,the measurement of the field current in this brushless system seem impossible.Considering that,the field current might be affected by the rectifier mode,the field current estimation method in different rectifier mode is studied in this paper.The main exciter(ME)rotor currents were restructured based on the ME flux equations.With these restructured rotor currents,the field current in different rectifier commutation mode is analyzed,then the field current estimation method considering the rectifier mode can be obtained.The experiments in different rectifier modes are carried out to verify the proposed method.展开更多
文摘The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance.
基金Anhui Province Key Research and Development Plan of the Ecological Environment Project(No.202104i07020016).
文摘In this study,Computational Fluid Dynamics(CFD)together with a component transport model are exploited to investigate the influence of dimensionless parameters,involving the height of the rectifier grid and the installation height of the first catalyst layer,on the flow field and the overall denitration efficiency of a cement kiln’s SCR(Selective catalytic reduction)denitrification reactor.It is shown that accurate numerical results can be obtained by fitting the particle size distribution function to the actual cement kiln fly ash and implementing a non-uniform particle inlet boundary condition.The relative error between denitration efficiency derived from experimental data,numerical simulation,and real-time system pressure drop ranges from 4%to 9%.Optimization of the SCR reactor is achieved when the rectifier grid thickness ratio k/H≥0.030,the rectifier grid height ratio h/H=0.04,and the spacing between the rectifier grid and the first catalyst layer l/H=0.10.Under these conditions,airflow distribution and particle dispersion upstream of the catalyst result in increased denitration efficiencies of 3.21%,3.43%,and 3.27%,respectively,compared to the least favorable operating conditions.
基金Project supported by the 13115 Innovation Engineering of Shaanxi Province of China(Grant No.2008ZDKG-30)
文摘This paper proposes a double epi-layers 4H-SiC junction barrier Schottky rectifier (JBSR) with embedded P layer (EPL) in the drift region. The structure is characterized by the P-type layer formed in the n-type drift layer by epitaxial overgrowth process. The electric field and potential distribution are changed due to the buried P-layer, resulting in a high breakdown voltage (BV) and low specific on-resistance (Ron,sp). The influences of device parameters, such as the depth of the embedded P+ regions, the space between them and the doping concentration of the drift region, etc., on BV and Ron,sp are investigated by simulations, which provides a particularly useful guideline for the optimal design of the device. The results indicate that BV is increased by 48.5% and Baliga's figure of merit (BFOM) is increased by 67.9% compared to a conventional 4H-SiC JBSR.
基金supported in part by the National Natural Science Foundation of China (No.51777093)
文摘This paper presents a cascode configuration synchronous rectifier device based on silicon MOSFET and Schottky diode,which can replace traditional power diode directly.This structure has self-driven ability with simple external circuit,and the conduction characteristic is preferable to a power diode.Static characterization and switching behavior analysis of proposed structure are conducted in this paper.The switching process is illustrated in detail using real model which considers the parasitic inductances and the nonlinearity of junction capacitors.The real time internal voltage and current value during switching transition are deduced with the equivalent circuit.To validate the analysis,two voltage specification rectifiers are built.Finally,double-pulse test results and the practical design example verify the performance advantages of proposed structure.
文摘基于二极管整流器的高压直流DR-HVDC(diode-rectifer-based high voltage direct current)输电系统是一种很有前景的海上风电低成本接入方案,它可将风能从偏远的海上风电场输送到陆上电力系统。然而随着海上DR-HVDC系统的不断增多,可能会导致风机WT(wind turbine)的变流器控制难度增大,系统稳定性变差。基于此,提出了一种适用于DR-HVDC连接海上WT变流器的新型电网形成控制方法。该方法采用2个正序控制回路来调节WTs的输出有功功率,并维持海上交流电网的频率和电压,其中第一个控制器可将每台WT的有功功率误差调节为电压角偏差,从而造成系统频率偏差;第二个控制器通过调整WT的交流电压幅值以抵消频率偏差。变流器内部电流控制回路用于限制故障电流,并消除系统中的高频谐振。最后,通过故障穿越、WT功率变化、无功扰动和WTs停机4个方面的电磁暂态仿真,验证了所提控制方法的有效性和优越性。
基金supported in part by the Natural Science Foundation of Shaanxi Province under Grant 2023JCQN0534in part by the Natural Science Foundation of Shaanxi Provincial Department of Education under Grant 23JK0660in part by the Xi’an Municipal Bureau of Science and Technology under Grant 24GXF0085。
文摘The information of the field current is essential for the brushless synchronous starter/generator system,which determines the performance and health status of this system.However,since the field winding of the main machine is installed in the rotor part,the measurement of the field current in this brushless system seem impossible.Considering that,the field current might be affected by the rectifier mode,the field current estimation method in different rectifier mode is studied in this paper.The main exciter(ME)rotor currents were restructured based on the ME flux equations.With these restructured rotor currents,the field current in different rectifier commutation mode is analyzed,then the field current estimation method considering the rectifier mode can be obtained.The experiments in different rectifier modes are carried out to verify the proposed method.