The study discussed the rapid method to test and predict the longevity of controlled release fertilizers (CRFs) coated by water soluble resin by using the short-term leaching under higher temperature. Pure water dis...The study discussed the rapid method to test and predict the longevity of controlled release fertilizers (CRFs) coated by water soluble resin by using the short-term leaching under higher temperature. Pure water dissolving incubation and higher temperature leaching were used to study the patterns of the nutrient release of the CRFs. The correlation analysis between the days at 25℃ and the hours at 80℃ of Trincote 1 and Trincote 2 for the same cumulative release rates were conducted. Patterns of cumulative nutrient release curve followed one factor quadratic regression equation at each given temperatures, and each of relative coefficient was bigger than 0.995. As the temperature increased, nutrients release of the CRFs increased. The longevity of resin coated CRFs were predicted by use of both the cumulative nutrients release equation at 80℃ and the regression equation of release time needed for the same cumulative release rates between 25 and 80℃. There were only 0.3-6.9% relative errors between the tested longevity and predicted one. In conclusion, the longevity of resin coated CRFs could be predicted more quickly and precisely by use of the higher temperature short-term leaching method than that of the traditional differential release rate. The longevity of resin coated CRF could be rapidly and precisely predicted in a few hours by application of the higher temperature shortterm leaching method.展开更多
Cowpea (Vigna unguiculata (L.) Walp), a legume crop that is grown in the worldwide, provides beneficial proteins for human consumption and animal feeding. In comparison, Rapid N analyzer as traditional method, has bee...Cowpea (Vigna unguiculata (L.) Walp), a legume crop that is grown in the worldwide, provides beneficial proteins for human consumption and animal feeding. In comparison, Rapid N analyzer as traditional method, has been widely used to measure protein content through the percentage of total nitrogen in the seed’s grounded powder. Near-Infrared Reflectance (NIR) has commonly been used to measure protein content in soybean seeds using whole grain without the need of seed grinding, which makes it possible to obtain fast results at a lower cost-per-analysis than the traditional combustion method. The specific objective of this study is to test a rapid method for measuring cowpea seed protein content by the NIR analyzer comparing to the traditional rapid N analyzer. A total of 240 cowpea genotypes were used in this study, including six seed coat colors, black, blackeye, browneye, cream, pinkeye, and red with 40 cowpea genotypes. The results showed that a linear relationship exists between the NIR analyzer and the Rapid N analyzer in the six different color groups. The correlation efficiency (r) between the seed protein contents from NIR and Rapid N was higher for pinkeye seed (r = 0.867), blackeye (0.771), cream (0.729), browneye (0.700), and red (0.623), respectively, but lower for black seeds, indicating that the NIR analyzer can be used to measure protein content for cowpea seeds with the five types of seed coat except black. Overview, the cowpea seed protein content measured from the NIR analyzer showed a little higher seed protein content. A series of regression models with different seed coat color have been built to adjust to protein content of colorful cowpea seeds from the NIR analyzer. But, it is not recommended to use for black color seeds due to a very low correlation efficiency (r) value with 0.184.展开更多
BACKGROUND Helicobacter pylori(H.pylori),a globally prevalent pathogen,is exhibiting increasing rates of antimicrobial resistance.However,clinical implementation of pre-treatment susceptibility testing remains limited...BACKGROUND Helicobacter pylori(H.pylori),a globally prevalent pathogen,is exhibiting increasing rates of antimicrobial resistance.However,clinical implementation of pre-treatment susceptibility testing remains limited due to the organism’s fastidious growth requirements and prolonged culture time.AIM To propose a novel detection method utilizing antibiotic-supplemented media to inhibit susceptible strains,while resistant isolates were identified through urease-mediated hydrolysis of urea,inducing a phenol red color change for visual confirmation.METHODS Colombia agar was supplemented with urea,phenol red,and nickel chloride,and the final pH was adjusted to 7.35.Antibiotic-selective media were prepared by incorporating amoxicillin(0.5μg/mL),clarithromycin(2μg/mL),metronidazole(8μg/mL),or levofloxacin(2μg/mL)into separate batches.Gastric antral biopsies were homogenized and inoculated at 1.0×105 CFU onto the media,and then incubated under microaerobic conditions at 37°C for 28-36 hours.Resistance was determined based on a color change from yellow to pink,and the results were validated via broth microdilution according to Clinical and Laboratory Standards Institute guidelines.RESULTS After 28-36 hours of incubation,the drug-resistant H.pylori isolates induced a light red color change in the medium.Conversely,susceptible strains(H.pylori 26695 and G27)produced no visible color change.Compared with the conventional 11-day protocol,the novel method significantly reduced detection time.Among 201 clinical isolates,182 were successfully evaluated using the new method,resulting in a 90.5%detection rate.This was consistent with the 95.5%agreement rate observed when compared with microdilution-based susceptibility testing.The success rate of the novel approach was significantly higher than that of the comparative method(P<0.01).The accuracy of the new method was comparable to that of the dilution method.CONCLUSION The novel detection method can rapidly detect H.pylori drug resistance within 28-36 hours.With its operational simplicity and high diagnostic performance,it holds strong potential for clinical application in the management of H.pylori antimicrobial resistance.展开更多
The crushing of leaves is the most time and effort-consuming part in DNA extraction which is a fundamental step in the study of molecular biology. In this study, a new rapid and batch-oriented crushing method for DNA ...The crushing of leaves is the most time and effort-consuming part in DNA extraction which is a fundamental step in the study of molecular biology. In this study, a new rapid and batch-oriented crushing method for DNA extraction from maize leaves was developed. In addition, the practicability of the developed method in molecular marker-assisted breeding was verified using SSR molecular maker technology so as to provide a rapid, batch-oriented, low-cost and non-toxic leafcrushing method for a large number of molecular marker tests, improving test efficiency.展开更多
The method to predict roll deformation precisely and efficiently is vital for the strip shape control of a six-high rolling mill. Traditional calculation methods of roll deformation, such as the finite element method ...The method to predict roll deformation precisely and efficiently is vital for the strip shape control of a six-high rolling mill. Traditional calculation methods of roll deformation, such as the finite element method and the influence function method, have been widely used due to their accuracies. However, the required calculation time is too long to be applied to the realtime control. Therefore, a rapid calculation method for predicting roll deformation of a six-high rolling mill was proposed, which employed the finite difference method to calculate the roll deflection and used a polynomial to describe the nonlinear relationship between roll flattening and roll contact pressure. Furthermore, a new correction strategy was proposed in the iteration, where the roll center flattening and the roll flattening deviation were put forward and corrected simultaneously in the iteration process according to the static equilibrium of roll. Finally, by the comparison with traditional methods, the proposed method was proved to be more efficient and it was suitable for the online calculation of the strip shape control.展开更多
Transplutonium isotopes are scarce and need to be produced by irradiation in high flux reactors.However,their production is inefficient,and optimization studies are necessary.This study analyzes the physical nature of...Transplutonium isotopes are scarce and need to be produced by irradiation in high flux reactors.However,their production is inefficient,and optimization studies are necessary.This study analyzes the physical nature of transplutonium isotope produc-tion using ^(252)Cf,^(244)Cm,^(242)Cm,and ^(238)Pu as examples.Traditional methods based on the Monte Carlo burnup calculation have the limitations of many calculations and cannot analyze the individual energy intervals in detail;thus,they cannot sup-port the refined evaluation,screening,and optimization of the irradiation schemes.After understanding the physical nature and simplifying the complexity of the production process,we propose a rapid diagnostic method for evaluating radiation schemes based on the concepts“single energy interval value(SEIV)”and“energy spectrum total value(ESTV)”.The rapid diagnostic method not only avoids tedious burnup calculations,but also provides a direction for optimization.The optimal irradiation schemes for producing ^(252)Cf,^(244)Cm,^(242)Cm,and ^(238)Pu are determined based on a rapid diagnostic method.Optimal irradiation schemes can significantly improve production efficiency.Compared with the initial scheme,the optimal scheme improved the production efficiency of ^(238)Pu by 7.41 times;^(242)Cm,11.98 times;^(244)Cm,65.20 times;and ^(252)Cf,15.08 times.Thus,a refined analysis of transplutonium isotope production is conducted and provides a theoretical basis for improving production efficiency.展开更多
To determine the concentrations of total oils,petroleum hydrocarbons,and animal and vegetable oils in water,the conventional analytical methods involve two scans as well as a step of magnesium silicate adsorption to r...To determine the concentrations of total oils,petroleum hydrocarbons,and animal and vegetable oils in water,the conventional analytical methods involve two scans as well as a step of magnesium silicate adsorption to remove the animal and vegetable oils in water samples.In this study,a novel analytical method was developed to determine the above oils in wastewater samples through just one scan—the concentration of animal and vegetable oils,and that of total oils were determined by measuring the absorbance of the 〉C=O bond in the peak area between 1750 cm and 1735 cm^(-1),and of the C-H bond at 2930 cm^(-1),2960 cm,and 3030 cm^(-1),respectively.The concentration of petroleum hydrocarbons was then calculated by subtracting the concentration of animal and vegetable oils from that of total oils.Compared with the well-known analytical method GB/T 16488-1996,the novel approach displayed similar accuracy in the quantitative determination of oils in wastewater samples,but significantly reduced material cost and operation time.展开更多
Human serum albumin(HSA)injectable product is a severely afflicted area on drug safety due to its high price and restricted supply.Raman spectroscopy performances high specificity on HSA detection and it is even possi...Human serum albumin(HSA)injectable product is a severely afflicted area on drug safety due to its high price and restricted supply.Raman spectroscopy performances high specificity on HSA detection and it is even possible to determine HSA injectable products noninvasively.In this study,we developed a noninvasive rapid screening method for of HSA injectable products by using portable Raman spectrometer.Qualitative models were established by using principal component analysis combined with classical least squares(PCA-CLS)algorithm,while quanti-tative model was established by using partial least squares(PLS)algorithm.Model transfer in different instruments of both the same and different apparatus modules was further discussed in this paper.A total of 34 HSA injectable samples collected from markets were used for verification.The identification results showed 100%accuracy and the predicted concentrations of those identified as true HSA were consistent with their labeled concentrations.The quantitative results also indicated that model transfer was excellent in the same apparatus modules of Raman spectrometer at all concentration levels,and still good enough in the different apparatus modules although the relative standard deviation(RSD)value showed a little increasing trend at low HSA concentration level.In conclusion,the method was proved to be feasible and efficient for screening HSA injections,especially on its screening speed and the consideration of glass containers.Moreover,with inspiring results on the model transfer,the method could be used as a universal screening mean to different Raman instruments.展开更多
Combined with the tire dynamics theoretical model,a rapid test method to obtain tire lateral and longitudinal both steady-state and transient characteristics only based on the tire quasi-steady-state test results is p...Combined with the tire dynamics theoretical model,a rapid test method to obtain tire lateral and longitudinal both steady-state and transient characteristics only based on the tire quasi-steady-state test results is proposed.For steady state data extraction,the test time of the rapid test method is half that of the conventional test method.For transient tire characteristics the rapid test method omits the traditional tire test totally.At the mean time the accuracy of the two method is much closed.The rapid test method is explained theoretically and the test process is designed.The key parameters of tire are extracted and the comparison is made between rapid test and traditional test method.The result show that the identification accuracy based on the rapid test method is almost equal to the accuracy of the conventional one.Then,the heat generated during the rapid test method and that generated during the conventional test are calculated separately.The comparison shows that the heat generated during the rapid test is much smaller than the heat generated during the conventional test process.This benefits to the reduction of tire wear and the consistency of test results.Finally,it can be concluded that the fast test method can efficiently,accurately and energy-efficiently measure the steady-state and transient characteristics of the tire.展开更多
Regarding the rapid compensation of the influence of the Earth' s disturbing gravity field upon trajectory calculation,the key point lies in how to derive the analytical solutions to the partial derivatives of the st...Regarding the rapid compensation of the influence of the Earth' s disturbing gravity field upon trajectory calculation,the key point lies in how to derive the analytical solutions to the partial derivatives of the state of burnout point with respect to the launch data.In view of this,this paper mainly expounds on two issues:one is based on the approximate analytical solution to the motion equation for the vacuum flight section of a long-range rocket,deriving the analytical solutions to the partial derivatives of the state of burnout point with respect to the changing rate of the finalstage pitch program;the other is based on the initial positioning and orientation error propagation mechanism,proposing the analytical calculation formula for the partial derivatives of the state of burnout point with respect to the launch azimuth.The calculation results of correction data are simulated and verified under different circumstances.The simulation results are as follows:(1) the accuracy of approximation between the analytical solutions and the results attained via the difference method is higher than 90%,and the ratio of calculation time between them is lower than 0.2%,thus demonstrating the accuracy of calculation of data corrections and advantages in calculation speed;(2) after the analytical solutions are compensated,the longitudinal landing deviation of the rocket is less than 20 m and the lateral landing deviation of the rocket is less than 10 m,demonstrating that the corrected data can meet the requirements for the hit accuracy of a long-range rocket.展开更多
Dengue virus infections are increasing worldwide generally and in Asia,Central and South America and Africa,particularly.It poses a serious threat to the children population.The rapid and accurate diagnostic systems a...Dengue virus infections are increasing worldwide generally and in Asia,Central and South America and Africa,particularly.It poses a serious threat to the children population.The rapid and accurate diagnostic systems are essentially required due to lack of effective vaccine against dengue virus and the progressive spread of the dengue virus infection.The recent progress in developing micro-and nano-fabrication techniques has led to low cost and scale down the biomedical point-of-care devices.Starting from the conventional and modern available methods for the diagnosis of dengue infection,this review examines several emerging rapid and point-of-care diagnostic devices that hold significant potential for the progress in smart diagnosis tools.The given review revealed that an effective vaccine is required urgently against all the dengue virus serotypes.However,the rapid detection methods of dengue virus help in early treatment and significantly reduce the dengue virus outbreak.展开更多
This study aimed to optimize the rapid test factors of dry basis weight of reconstituted tobacco, in order to afford a reference test method for companies which produce reconstituted tobacco to better control the basi...This study aimed to optimize the rapid test factors of dry basis weight of reconstituted tobacco, in order to afford a reference test method for companies which produce reconstituted tobacco to better control the basis weight and coating ratio on line. The dry basis weight of reconstituted tobacco was tested by fast method and normal oven method individually. And the effects on the test values of different test factors such as temperature, time and the number of baking sheets were studied. Then the test values of these two methods were compared, so the proper factors of rapid test method were determined. As the baking temperature rose from 130 ℃ to 150 ℃, and the baking time rose from 1 min to 2 min, the difference between fast test method and normal oven method grew, and when the number of baking pieces rose from 3 pieces to 5 pieces, the difference between the two methods went down. The optimum test condition was baking temperature of 130 ℃, baking time of 1 min, and baking sample sheet number of 5. Under this condition, the value of fast test method was the closest to the test value of normal oven method, and meanwhile, the test factor was more proper for testing on line. The study will provide a reference for online controlling of dry basis weight and coating ratio of reconstituted tobacco.展开更多
Background: Myeloperoxidase staining is used to differentiate leukemias since several decades. Despite implementation of flow cytometric, cytogenetic and molecular techniques for identification of leukemic blasts, his...Background: Myeloperoxidase staining is used to differentiate leukemias since several decades. Despite implementation of flow cytometric, cytogenetic and molecular techniques for identification of leukemic blasts, histochemical stains such as myeloperoxidase stain are persistently used for better classification of leukemias. The myeloperoxidase staining is a time consuming and hazardous procedure. The present report describes a sensitive, rapid and easy method for assessment of peroxidase activity. Materials and Methods: Bone marrow aspiration slides were stained with Dako product: Code number: K3467 containing DAB chromogen (3,3-diaminobenzidine in chromogen solution) and substrate buffer (Imidasole-HCL buffer, PH 7.5 containing hydrogen peroxide and an anti microbial agent) in a rapid procedure taking only ten minutes time. The staining needs no material preparation steps. Neutrophils in the slide are taken as positive control or another normal smear was costained to be used as control. All cases were followed up with flow cytometry and cytogenetic studies. Result: The reaction product of this stain is brown and granular. Promyelocytes and myelocytes are the most strongly staining cells with positive (primary) granules. Lymphoblasts are negative. The result of classification of leukemias with this technique was in concordance with flow cytometric immunophenotyping. Discussion: Many practical techniques have been described using benzidine as an indicator for myeloperoxidase staining. Benzidine is a carcinogenic material and its usage is severely restricted in laboratory. Formerly we prepared requisite materials for myeloperoxidase staining by hazardous ways (boiling), but we decided to apply ready to use 3,3-diaminobenzidine (DAB), which is used in final step of immunohistochemistry stains. Conclusion: Use of 3,3-diaminobenzidine (DAB) is highly recommended for myeloperoxidase staining, while the result is extraordinary and fully compatible with flow cytometry and the method is safe and rapid.展开更多
[Objectives ] The paper was to explore enzyme inhibition rate method for rapid detection of organophosphorus and carbamate pesticides in cowpea. [ Methods ] Acetylcholinesterase (ACHE) was added to cowpea extract, t...[Objectives ] The paper was to explore enzyme inhibition rate method for rapid detection of organophosphorus and carbamate pesticides in cowpea. [ Methods ] Acetylcholinesterase (ACHE) was added to cowpea extract, to determine the inhibition rate of extract against enzyme. The influences of different sampiing methods and sampling parts on detection results were compared. [ Results] The positive rate of standard sampling was 18.18% higher than that of non-stand- ard sampling, and the positive rate of samples collected from cowpea tail was 16.67% higher than that collected from other parts. [ Condmions] Enzyme inhibi- tion rate method is suitable for rapid detection of organophosphorus and carbamate pesticides in cowpea.展开更多
In view of the limited space of offshore platform and the large amount of polymer injection, the dissolution time method, solution viscosity method, conductivity method, undissolved filtration method and falling ball ...In view of the limited space of offshore platform and the large amount of polymer injection, the dissolution time method, solution viscosity method, conductivity method, undissolved filtration method and falling ball method are used as the rapid detection methods of polymer dissolution. The results show that the error of conductivity method is the largest, and that of dissolution time method is the second, and both methods are time-consuming. Solution viscosity method and insolubles filtration method have small error, but they are time-consuming, especially for offshore platforms, which makes detection inconvenient. The drop ball method is simple in operation and has a small error, so it is a promising method for rapid determination of polymer dissolution time.展开更多
基金the National Key Technologies R&D Program during the 11th Five-Year Plan period of China (2006BAD10B02)the National Natural Science Foundation of China (39870433,30270769)
文摘The study discussed the rapid method to test and predict the longevity of controlled release fertilizers (CRFs) coated by water soluble resin by using the short-term leaching under higher temperature. Pure water dissolving incubation and higher temperature leaching were used to study the patterns of the nutrient release of the CRFs. The correlation analysis between the days at 25℃ and the hours at 80℃ of Trincote 1 and Trincote 2 for the same cumulative release rates were conducted. Patterns of cumulative nutrient release curve followed one factor quadratic regression equation at each given temperatures, and each of relative coefficient was bigger than 0.995. As the temperature increased, nutrients release of the CRFs increased. The longevity of resin coated CRFs were predicted by use of both the cumulative nutrients release equation at 80℃ and the regression equation of release time needed for the same cumulative release rates between 25 and 80℃. There were only 0.3-6.9% relative errors between the tested longevity and predicted one. In conclusion, the longevity of resin coated CRFs could be predicted more quickly and precisely by use of the higher temperature short-term leaching method than that of the traditional differential release rate. The longevity of resin coated CRF could be rapidly and precisely predicted in a few hours by application of the higher temperature shortterm leaching method.
文摘Cowpea (Vigna unguiculata (L.) Walp), a legume crop that is grown in the worldwide, provides beneficial proteins for human consumption and animal feeding. In comparison, Rapid N analyzer as traditional method, has been widely used to measure protein content through the percentage of total nitrogen in the seed’s grounded powder. Near-Infrared Reflectance (NIR) has commonly been used to measure protein content in soybean seeds using whole grain without the need of seed grinding, which makes it possible to obtain fast results at a lower cost-per-analysis than the traditional combustion method. The specific objective of this study is to test a rapid method for measuring cowpea seed protein content by the NIR analyzer comparing to the traditional rapid N analyzer. A total of 240 cowpea genotypes were used in this study, including six seed coat colors, black, blackeye, browneye, cream, pinkeye, and red with 40 cowpea genotypes. The results showed that a linear relationship exists between the NIR analyzer and the Rapid N analyzer in the six different color groups. The correlation efficiency (r) between the seed protein contents from NIR and Rapid N was higher for pinkeye seed (r = 0.867), blackeye (0.771), cream (0.729), browneye (0.700), and red (0.623), respectively, but lower for black seeds, indicating that the NIR analyzer can be used to measure protein content for cowpea seeds with the five types of seed coat except black. Overview, the cowpea seed protein content measured from the NIR analyzer showed a little higher seed protein content. A series of regression models with different seed coat color have been built to adjust to protein content of colorful cowpea seeds from the NIR analyzer. But, it is not recommended to use for black color seeds due to a very low correlation efficiency (r) value with 0.184.
基金Supported by the Guangxi Science and Technology Major Projects,No.AA23073012the National Natural Science Foundation of China,No.32360035 and No.32060018。
文摘BACKGROUND Helicobacter pylori(H.pylori),a globally prevalent pathogen,is exhibiting increasing rates of antimicrobial resistance.However,clinical implementation of pre-treatment susceptibility testing remains limited due to the organism’s fastidious growth requirements and prolonged culture time.AIM To propose a novel detection method utilizing antibiotic-supplemented media to inhibit susceptible strains,while resistant isolates were identified through urease-mediated hydrolysis of urea,inducing a phenol red color change for visual confirmation.METHODS Colombia agar was supplemented with urea,phenol red,and nickel chloride,and the final pH was adjusted to 7.35.Antibiotic-selective media were prepared by incorporating amoxicillin(0.5μg/mL),clarithromycin(2μg/mL),metronidazole(8μg/mL),or levofloxacin(2μg/mL)into separate batches.Gastric antral biopsies were homogenized and inoculated at 1.0×105 CFU onto the media,and then incubated under microaerobic conditions at 37°C for 28-36 hours.Resistance was determined based on a color change from yellow to pink,and the results were validated via broth microdilution according to Clinical and Laboratory Standards Institute guidelines.RESULTS After 28-36 hours of incubation,the drug-resistant H.pylori isolates induced a light red color change in the medium.Conversely,susceptible strains(H.pylori 26695 and G27)produced no visible color change.Compared with the conventional 11-day protocol,the novel method significantly reduced detection time.Among 201 clinical isolates,182 were successfully evaluated using the new method,resulting in a 90.5%detection rate.This was consistent with the 95.5%agreement rate observed when compared with microdilution-based susceptibility testing.The success rate of the novel approach was significantly higher than that of the comparative method(P<0.01).The accuracy of the new method was comparable to that of the dilution method.CONCLUSION The novel detection method can rapidly detect H.pylori drug resistance within 28-36 hours.With its operational simplicity and high diagnostic performance,it holds strong potential for clinical application in the management of H.pylori antimicrobial resistance.
基金Supported by Special Fund for Agro-scientific Research in the Public Interest of China(201303008)Science and Technology Plan Project of Guangdong Province(2012B020301006)Key Breeding Project for Special Maize of Department of Agriculture of Guangdong Province(B3071328)~~
文摘The crushing of leaves is the most time and effort-consuming part in DNA extraction which is a fundamental step in the study of molecular biology. In this study, a new rapid and batch-oriented crushing method for DNA extraction from maize leaves was developed. In addition, the practicability of the developed method in molecular marker-assisted breeding was verified using SSR molecular maker technology so as to provide a rapid, batch-oriented, low-cost and non-toxic leafcrushing method for a large number of molecular marker tests, improving test efficiency.
基金This work was financially supported by the National Natural Science Foundation of China (51674028), and Fundamental Research Funds for the Central Universities (FRF-IC- 16-001).
文摘The method to predict roll deformation precisely and efficiently is vital for the strip shape control of a six-high rolling mill. Traditional calculation methods of roll deformation, such as the finite element method and the influence function method, have been widely used due to their accuracies. However, the required calculation time is too long to be applied to the realtime control. Therefore, a rapid calculation method for predicting roll deformation of a six-high rolling mill was proposed, which employed the finite difference method to calculate the roll deflection and used a polynomial to describe the nonlinear relationship between roll flattening and roll contact pressure. Furthermore, a new correction strategy was proposed in the iteration, where the roll center flattening and the roll flattening deviation were put forward and corrected simultaneously in the iteration process according to the static equilibrium of roll. Finally, by the comparison with traditional methods, the proposed method was proved to be more efficient and it was suitable for the online calculation of the strip shape control.
基金sponsored by Natural Science Foundation of Shanghai (NO.22ZR1431900)Science and Technology on Reactor System Design Technology Laboratory.
文摘Transplutonium isotopes are scarce and need to be produced by irradiation in high flux reactors.However,their production is inefficient,and optimization studies are necessary.This study analyzes the physical nature of transplutonium isotope produc-tion using ^(252)Cf,^(244)Cm,^(242)Cm,and ^(238)Pu as examples.Traditional methods based on the Monte Carlo burnup calculation have the limitations of many calculations and cannot analyze the individual energy intervals in detail;thus,they cannot sup-port the refined evaluation,screening,and optimization of the irradiation schemes.After understanding the physical nature and simplifying the complexity of the production process,we propose a rapid diagnostic method for evaluating radiation schemes based on the concepts“single energy interval value(SEIV)”and“energy spectrum total value(ESTV)”.The rapid diagnostic method not only avoids tedious burnup calculations,but also provides a direction for optimization.The optimal irradiation schemes for producing ^(252)Cf,^(244)Cm,^(242)Cm,and ^(238)Pu are determined based on a rapid diagnostic method.Optimal irradiation schemes can significantly improve production efficiency.Compared with the initial scheme,the optimal scheme improved the production efficiency of ^(238)Pu by 7.41 times;^(242)Cm,11.98 times;^(244)Cm,65.20 times;and ^(252)Cf,15.08 times.Thus,a refined analysis of transplutonium isotope production is conducted and provides a theoretical basis for improving production efficiency.
基金supported by the National Program of Drawing and Revising of Environmental Protection Standards (No.997.3)the State Key Program of National Natural Science(No.50938004)+3 种基金the National Natural Science Foundation for Distinguished Young Scientists(No.50825802)Jiangsu Nature Science Foundation(No. BK2010006)the Resources Key Subject of National High Technology Research & Development Project (863 ProjectNos.2009AA06Z315 and SQ2009AA06XK1482331)from China
文摘To determine the concentrations of total oils,petroleum hydrocarbons,and animal and vegetable oils in water,the conventional analytical methods involve two scans as well as a step of magnesium silicate adsorption to remove the animal and vegetable oils in water samples.In this study,a novel analytical method was developed to determine the above oils in wastewater samples through just one scan—the concentration of animal and vegetable oils,and that of total oils were determined by measuring the absorbance of the 〉C=O bond in the peak area between 1750 cm and 1735 cm^(-1),and of the C-H bond at 2930 cm^(-1),2960 cm,and 3030 cm^(-1),respectively.The concentration of petroleum hydrocarbons was then calculated by subtracting the concentration of animal and vegetable oils from that of total oils.Compared with the well-known analytical method GB/T 16488-1996,the novel approach displayed similar accuracy in the quantitative determination of oils in wastewater samples,but significantly reduced material cost and operation time.
基金Youth Develop-ment Research Foundation(No.2015C03)of Na-tional Institutes of Food and Drug Control,P.R.China.
文摘Human serum albumin(HSA)injectable product is a severely afflicted area on drug safety due to its high price and restricted supply.Raman spectroscopy performances high specificity on HSA detection and it is even possible to determine HSA injectable products noninvasively.In this study,we developed a noninvasive rapid screening method for of HSA injectable products by using portable Raman spectrometer.Qualitative models were established by using principal component analysis combined with classical least squares(PCA-CLS)algorithm,while quanti-tative model was established by using partial least squares(PLS)algorithm.Model transfer in different instruments of both the same and different apparatus modules was further discussed in this paper.A total of 34 HSA injectable samples collected from markets were used for verification.The identification results showed 100%accuracy and the predicted concentrations of those identified as true HSA were consistent with their labeled concentrations.The quantitative results also indicated that model transfer was excellent in the same apparatus modules of Raman spectrometer at all concentration levels,and still good enough in the different apparatus modules although the relative standard deviation(RSD)value showed a little increasing trend at low HSA concentration level.In conclusion,the method was proved to be feasible and efficient for screening HSA injections,especially on its screening speed and the consideration of glass containers.Moreover,with inspiring results on the model transfer,the method could be used as a universal screening mean to different Raman instruments.
基金Supported by National Natural Science Foundation of China(Grant No.51775224).
文摘Combined with the tire dynamics theoretical model,a rapid test method to obtain tire lateral and longitudinal both steady-state and transient characteristics only based on the tire quasi-steady-state test results is proposed.For steady state data extraction,the test time of the rapid test method is half that of the conventional test method.For transient tire characteristics the rapid test method omits the traditional tire test totally.At the mean time the accuracy of the two method is much closed.The rapid test method is explained theoretically and the test process is designed.The key parameters of tire are extracted and the comparison is made between rapid test and traditional test method.The result show that the identification accuracy based on the rapid test method is almost equal to the accuracy of the conventional one.Then,the heat generated during the rapid test method and that generated during the conventional test are calculated separately.The comparison shows that the heat generated during the rapid test is much smaller than the heat generated during the conventional test process.This benefits to the reduction of tire wear and the consistency of test results.Finally,it can be concluded that the fast test method can efficiently,accurately and energy-efficiently measure the steady-state and transient characteristics of the tire.
文摘Regarding the rapid compensation of the influence of the Earth' s disturbing gravity field upon trajectory calculation,the key point lies in how to derive the analytical solutions to the partial derivatives of the state of burnout point with respect to the launch data.In view of this,this paper mainly expounds on two issues:one is based on the approximate analytical solution to the motion equation for the vacuum flight section of a long-range rocket,deriving the analytical solutions to the partial derivatives of the state of burnout point with respect to the changing rate of the finalstage pitch program;the other is based on the initial positioning and orientation error propagation mechanism,proposing the analytical calculation formula for the partial derivatives of the state of burnout point with respect to the launch azimuth.The calculation results of correction data are simulated and verified under different circumstances.The simulation results are as follows:(1) the accuracy of approximation between the analytical solutions and the results attained via the difference method is higher than 90%,and the ratio of calculation time between them is lower than 0.2%,thus demonstrating the accuracy of calculation of data corrections and advantages in calculation speed;(2) after the analytical solutions are compensated,the longitudinal landing deviation of the rocket is less than 20 m and the lateral landing deviation of the rocket is less than 10 m,demonstrating that the corrected data can meet the requirements for the hit accuracy of a long-range rocket.
基金supported by the Scientific Research Fund of the Shenzhen International cooperation projects under Grant Nos.(GJHZ20190819151403615)the Natural Science Youth Foundation of China(61801307).
文摘Dengue virus infections are increasing worldwide generally and in Asia,Central and South America and Africa,particularly.It poses a serious threat to the children population.The rapid and accurate diagnostic systems are essentially required due to lack of effective vaccine against dengue virus and the progressive spread of the dengue virus infection.The recent progress in developing micro-and nano-fabrication techniques has led to low cost and scale down the biomedical point-of-care devices.Starting from the conventional and modern available methods for the diagnosis of dengue infection,this review examines several emerging rapid and point-of-care diagnostic devices that hold significant potential for the progress in smart diagnosis tools.The given review revealed that an effective vaccine is required urgently against all the dengue virus serotypes.However,the rapid detection methods of dengue virus help in early treatment and significantly reduce the dengue virus outbreak.
基金Supported by Science and Technology Planning Project of China Tobacco Schweitzer(Yunnan)Reconstituted Tobacco Co.,Ltd.(KY-17-ZL-01)China Tobacco Yunnan Industrial Co.,Ltd.(2016YL02)
文摘This study aimed to optimize the rapid test factors of dry basis weight of reconstituted tobacco, in order to afford a reference test method for companies which produce reconstituted tobacco to better control the basis weight and coating ratio on line. The dry basis weight of reconstituted tobacco was tested by fast method and normal oven method individually. And the effects on the test values of different test factors such as temperature, time and the number of baking sheets were studied. Then the test values of these two methods were compared, so the proper factors of rapid test method were determined. As the baking temperature rose from 130 ℃ to 150 ℃, and the baking time rose from 1 min to 2 min, the difference between fast test method and normal oven method grew, and when the number of baking pieces rose from 3 pieces to 5 pieces, the difference between the two methods went down. The optimum test condition was baking temperature of 130 ℃, baking time of 1 min, and baking sample sheet number of 5. Under this condition, the value of fast test method was the closest to the test value of normal oven method, and meanwhile, the test factor was more proper for testing on line. The study will provide a reference for online controlling of dry basis weight and coating ratio of reconstituted tobacco.
文摘Background: Myeloperoxidase staining is used to differentiate leukemias since several decades. Despite implementation of flow cytometric, cytogenetic and molecular techniques for identification of leukemic blasts, histochemical stains such as myeloperoxidase stain are persistently used for better classification of leukemias. The myeloperoxidase staining is a time consuming and hazardous procedure. The present report describes a sensitive, rapid and easy method for assessment of peroxidase activity. Materials and Methods: Bone marrow aspiration slides were stained with Dako product: Code number: K3467 containing DAB chromogen (3,3-diaminobenzidine in chromogen solution) and substrate buffer (Imidasole-HCL buffer, PH 7.5 containing hydrogen peroxide and an anti microbial agent) in a rapid procedure taking only ten minutes time. The staining needs no material preparation steps. Neutrophils in the slide are taken as positive control or another normal smear was costained to be used as control. All cases were followed up with flow cytometry and cytogenetic studies. Result: The reaction product of this stain is brown and granular. Promyelocytes and myelocytes are the most strongly staining cells with positive (primary) granules. Lymphoblasts are negative. The result of classification of leukemias with this technique was in concordance with flow cytometric immunophenotyping. Discussion: Many practical techniques have been described using benzidine as an indicator for myeloperoxidase staining. Benzidine is a carcinogenic material and its usage is severely restricted in laboratory. Formerly we prepared requisite materials for myeloperoxidase staining by hazardous ways (boiling), but we decided to apply ready to use 3,3-diaminobenzidine (DAB), which is used in final step of immunohistochemistry stains. Conclusion: Use of 3,3-diaminobenzidine (DAB) is highly recommended for myeloperoxidase staining, while the result is extraordinary and fully compatible with flow cytometry and the method is safe and rapid.
文摘[Objectives ] The paper was to explore enzyme inhibition rate method for rapid detection of organophosphorus and carbamate pesticides in cowpea. [ Methods ] Acetylcholinesterase (ACHE) was added to cowpea extract, to determine the inhibition rate of extract against enzyme. The influences of different sampiing methods and sampling parts on detection results were compared. [ Results] The positive rate of standard sampling was 18.18% higher than that of non-stand- ard sampling, and the positive rate of samples collected from cowpea tail was 16.67% higher than that collected from other parts. [ Condmions] Enzyme inhibi- tion rate method is suitable for rapid detection of organophosphorus and carbamate pesticides in cowpea.
文摘In view of the limited space of offshore platform and the large amount of polymer injection, the dissolution time method, solution viscosity method, conductivity method, undissolved filtration method and falling ball method are used as the rapid detection methods of polymer dissolution. The results show that the error of conductivity method is the largest, and that of dissolution time method is the second, and both methods are time-consuming. Solution viscosity method and insolubles filtration method have small error, but they are time-consuming, especially for offshore platforms, which makes detection inconvenient. The drop ball method is simple in operation and has a small error, so it is a promising method for rapid determination of polymer dissolution time.