期刊文献+
共找到140篇文章
< 1 2 7 >
每页显示 20 50 100
Bound States in the Continuum of Infinite Quality Factor in Finite Unit Cells
1
作者 Hua-Wei Liang Yuan-Zhi Liu +2 位作者 Yu-Jia Zeng Yang-Jian Cai Ting-Yin Ning 《Chinese Physics Letters》 2025年第8期38-53,共16页
A theory based on the superposition principle is developed to uncover the basic physics of wave behavior in a finite grating of N unit cells.The theory reveals that bound states in the continuum(BICs)of infinite quali... A theory based on the superposition principle is developed to uncover the basic physics of wave behavior in a finite grating of N unit cells.The theory reveals that bound states in the continuum(BICs)of infinite quality factor(Q-factor)can be supported by such a grating when perfect reflection is introduced at its boundaries.If geometrical perturbations are introduced into the structure,the dark BICs transform into bright quasi-BICs with finite Q-factor,maintaining spectral characteristics nearly identical to those of quasi-BICs supported by infinite gratings.When the boundaries are replaced with high-reflectivity metallic mirrors,the Q-factor of the resonant mode is reduced to be finite;however,it can be much larger than that in the corresponding nanostructure with open boundaries and can be tuned over a large range by varying the number of unit cells or boundary conditions. 展开更多
关键词 Superposition Principle wave behavior perfect reflection Finite Unit Cells geometrical perturbations dark bics Bound States Continuum Infinite quality factor
原文传递
Topology-optimized 2D silicon–air phononic crystal slabs for enhancing quality factor of laterally vibrating resonators
2
作者 Zihao Xie Yongqing Fu Jin Xie 《Nanotechnology and Precision Engineering》 2025年第1期36-44,共9页
Two-dimensional phononic crystal(PnC)slabs have shown advantages in enhancing the quality factors Q of piezoelectric laterally vibrating resonators(LVRs)through topology optimization.However,the narrow geometries of m... Two-dimensional phononic crystal(PnC)slabs have shown advantages in enhancing the quality factors Q of piezoelectric laterally vibrating resonators(LVRs)through topology optimization.However,the narrow geometries of most topology-optimized silicon–air 2D PnC slabs face significant fabrication challenges owing to restricted etching precision,and the anisotropic nature of silicon is frequently overlooked.To address these issues,this study employs the finite element method with appropriate discretization numbers and the genetic algorithm to optimize the structures and geometries of 2D silicon–air PnC slabs.The optimized square-lattice PnC slabs,featuring a rounded-cross structure oriented along the`110e directions of silicon,achieve an impressive relative bandgap(RBG)width of 82.2%for in-plane modes.When further tilted by 15° from the (100) directions within the(001)plane,the optimal RBG width is expanded to 91.4%.We fabricate and characterize thin-film piezoelectric-on-silicon LVRs,with or without optimized 2D PnC slabs.The presence of PnC slabs around anchors increases the series and parallel quality factors Q_(s) and Q_(p) from 2240 to 7118 and from 2237 to 7501,respectively,with the PnC slabs oriented along the`110e directions of silicon. 展开更多
关键词 Laterally vibrating resonators Phononic crystal slabs Topology optimization quality factor
在线阅读 下载PDF
Ultra-high quality factor and ultra-high accelerating gradient achievements in a 1.3 GHz continuous wave cryomodule
3
作者 Jin-Fang Chen Yue Zong +35 位作者 Xiao-Yun Pu Sheng-Wang Xiang Shuai Xing Zheng Li Xu-Ming Liu Yan-Fei Zhai Xiao-Wei Wu Yong-Zhou He Ling-Ling Gong Ji-Dong Zhang Shan-Shan Cao Wen-Ding Fang Bin-Tuan Zhang Kai Xu Yi-Bo Yu Guang-Hua Chen Li-Jun Lu Ya-Wei Huang Shen-Jie Zhao Hong-Tao Hou Zhen-Yu Ma Ye-Liang Zhao Xiang Zheng Jiu-Ce Sun Sen Sun Zhi-Qiang Jiang Yu-Bin Zhao Meng Zhang Ying-Bing Yan Yi-Yong Liu Qiang Gu Bo Liu Li-Xin Yin Dong Wang Hai-Xiao Deng Zhen-Tang Zhao 《Nuclear Science and Techniques》 2025年第2期18-26,共9页
We report the world-leading performance of a 1.3 GHz cryomodule equipped with eight 9-cell superconducting radio-frequency cavities that underwent a medium-temperature furnace baking process.During continuous wave hor... We report the world-leading performance of a 1.3 GHz cryomodule equipped with eight 9-cell superconducting radio-frequency cavities that underwent a medium-temperature furnace baking process.During continuous wave horizontal testing,these cavities achieved unprecedented average intrinsic quality factors of 4.0×10^(10)at 20 MV/m and 3.2×10^(10)at 29 MV/m,with no instances of field emission.The cryomodule demonstrates near-complete preservation of ultra-high quality factors and ultra-high accelerating gradients from vertical to horizontal testing,marking a significant milestone in continuous-wave superconducting radio-frequency accelerator technology.This letter presents the cryomodule development experience,includ-ing cavity preparation,cryomodule assembly,degaussing,fast cooldown,and performance testing. 展开更多
关键词 SRF cryomodule Mid-T baking High quality factor High accelerating gradient
在线阅读 下载PDF
Enhancement of Quality Factor in Gain-Assisted Acoustic Resonance Systems
4
作者 Lei Zhang Linlin Geng +3 位作者 Yonghui Zhang Youdong Duan Jinbo Yuan Xiaoming Zhou 《Acta Mechanica Solida Sinica》 2025年第1期25-32,共8页
Damped acoustic systems have a limited quality factor due to intrinsic loss.By introducing gain elements,a method to enhance the quality factor of damped systems is proposed based on the concept of bound states in the... Damped acoustic systems have a limited quality factor due to intrinsic loss.By introducing gain elements,a method to enhance the quality factor of damped systems is proposed based on the concept of bound states in the continuum(BICs).The acoustic model under study is a two-port waveguide system installed with two side Helmholtz resonators connected by a coupling tube.Based on the temporal coupled-mode theory,a Hamiltonian matrix with both intrinsic and radiation losses is used to characterize the resonance behavior of the coupled resonators.To achieve a high quality factor,acoustic gain is introduced to compensate the intrinsic loss,leading the Hamiltonian parameters toward a quasi-BIC condition.Numerical simulation demonstrates a gain-assisted and quasi-BIC-supported extremely high quality factor in damped acoustic systems.The concept is further utilized to design a sensor model for particle size detection.The enhanced sensing performance due to high quality factors is numerically demonstrated.The findings suggest potential applications in acoustic sensing and detection devices. 展开更多
关键词 Acoustic resonance quality factor Bound states in the continum Coupled-mode theory
原文传递
Effects of air damping on quality factors of different probes in tapping mode atomic force microscopy
5
作者 Yu Zeng Guo-Lin Liu +1 位作者 Jin-Hao Liu Zheng Wei 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期506-519,共14页
The AFM probe in tapping mode is a continuous process of energy dissipation,from moving away from to intermittent contact with the sample surfaces.At present,studies regarding the energy dissipation mechanism of this ... The AFM probe in tapping mode is a continuous process of energy dissipation,from moving away from to intermittent contact with the sample surfaces.At present,studies regarding the energy dissipation mechanism of this continuous process have only been reported sporadically,and there are no systematic explanations or experimental verifications of the energy dissipation mechanism in each stage of the continuous process.The quality factors can be used to characterize the energy dissipation in TM-AFM systems.In this study,the vibration model of the microcantilever beam was established,coupling the vibration and damping effects of the microcantilever beam.The quality factor of the vibrating microcantilever beam under damping was derived,and the air viscous damping when the probe is away from the sample and the air squeeze film damping when the probe is close to the sample were calculated.In addition,the mechanism of the damping effects of different shapes of probes at different tip–sample distances was analyzed.The accuracy of the theoretical simplified model was verified using both experimental and simulation methods.A clearer understanding of the kinetic characteristics and damping mechanism of the TM-AFM was achieved by examining the air damping dissipation mechanism of AFM probes in the tapping mode,which was very important for improving both the quality factor and the imaging quality of the TM-AFM system.This study’s research findings also provided theoretical references and experimental methods for the future study of the energy dissipation mechanism of micro-nano-electromechanical systems. 展开更多
关键词 TM-AFM quality factors air viscous damping air squeeze film damping
原文传递
Nanodiamond/Ti_(3)C_(2) MXene-coated quartz crystal microbalance humidity sensor with high sensitivity and high quality factor
6
作者 Yao Yao Qiao Chen +5 位作者 Yan-Qi Li Xian-He Huang Wei-Wei Ling Zhe-MiaoXie Jia-QiWang Chang-Ming Chen 《Rare Metals》 SCIE EI CAS CSCD 2024年第6期2719-2729,共11页
To address the challenge of achieving both high sensitivity and a high quality factor in quartz crystal microbalance(QCM)humidity sensors,a nanodiamond(ND)/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was fab... To address the challenge of achieving both high sensitivity and a high quality factor in quartz crystal microbalance(QCM)humidity sensors,a nanodiamond(ND)/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was fabricated.The material characteristics of ND,Ti_(3)C_(2)MXene,and ND/Ti_(3)C_(2)MXene composite were analyzed by transmission electron microscopy(TEM)and Fourier transform infrared(FTIR)spectroscopy.The experimental results demonstrated that the hydrophilic ND nanoparticles coated on Ti_(3)C_(2) MXene nanosheet prevented the self-stacking of Ti_(3)C_(2)MXene and enhanced the sensitivity of Ti_(3)C_(2) MXene-based QCM humidity sensor.Moreover,the high mechanical modulus of Ti_(3)C_(2) MXene material helped ND/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor to achieve a high quality factor(>20,000).ND/Ti_(3)C_(2)MXene compositecoated QCM humidity sensor exhibited a sensitivity of 82.45 Hz/%RH,a humidity hysteresis of 1.1%RH,fast response/recovery times,acceptable repeatability,and good stability from 11.3%RH to 97.3%RH.The response mechanism of ND/Ti_(3)C_(2) MXene composite-coated QCM humidity sensor was analyzed in combination with a bi-exponential kinetic adsorption model.Finally,the potential application of ND/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was demonstrated through its frequency response to wooden blocks with different moisture contents. 展开更多
关键词 Humidity sensor Quartz crystal microbalance NANODIAMOND Ti_(3)C_(2)MXene High quality factor
原文传递
Comparison of Mode Quality Factors for Equilateral Triangular, Square and Rhombus Optical Micro-Resonators
7
作者 黄永箴 国伟华 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2001年第2期117-120,共4页
The mode frequencies and the quality factors for the equilateral triangular resonator (ETR), the square resonator (SR) and the rhombus resonator (RR) are numerically calculated by the finite difference time domai... The mode frequencies and the quality factors for the equilateral triangular resonator (ETR), the square resonator (SR) and the rhombus resonator (RR) are numerically calculated by the finite difference time domain technique and the Padé approximation. The numerical results show that the resonant modes confined in an equilateral triangular cavity have much higher quality factors than those in the square or the rhombus cavities. The modes in the ETR are totally confined in transverse direction while those in the SR and RR are only partly confined. For the ETR with the side length of 4μm and the refractive index of 3 2, the mode quality factor of about 5 5×10 3 at the wavelength of 1 55μm has been obtained. 展开更多
关键词 MICRORESONATOR quality factor resonant frequency finite difference time domain technique semiconductor laser
在线阅读 下载PDF
Estimation of quality factors by energy ratio method 被引量:2
8
作者 王宗俊 曹思远 +5 位作者 张浩然 曲英铭 袁殿 杨金浩 张德龙 邵冠铭 《Applied Geophysics》 SCIE CSCD 2015年第1期86-92,122,123,共9页
The quality factor Q, which reflects the energy attenuation of seismic waves in subsurface media, is a diagnostic tool for hydrocarbon detection and reservoir characterization. In this paper, we propose a new Q extrac... The quality factor Q, which reflects the energy attenuation of seismic waves in subsurface media, is a diagnostic tool for hydrocarbon detection and reservoir characterization. In this paper, we propose a new Q extraction method based on the energy ratio before and after the wavelet attenuation, named the energy-ratio method(ERM). The proposed method uses multipoint signal data in the time domain to estimate the wavelet energy without invoking the source wavelet spectrum, which is necessary in conventional Q extraction methods, and is applicable to any source wavelet spectrum; however, it requires high-precision seismic data. Forward zero-offset VSP modeling suggests that the ERM can be used for reliable Q inversion after nonintrinsic attenuation(geometric dispersion, refl ection, and transmission loss) compensation. The application to real zero-offset VSP data shows that the Q values extracted by the ERM and spectral ratio methods are identical, which proves the reliability of the new method. 展开更多
关键词 quality factor Q energy ratio time domain seismic wavelet spectral ratio method
在线阅读 下载PDF
Novel S-slot DGS with high quality factor
9
作者 朱轶智 张晓娟 方广有 《Journal of Southeast University(English Edition)》 EI CAS 2009年第4期431-434,共4页
In order to solve the problem that the quality factor ( Q factor) of the conventional defected ground structure (DGS)is not high and cannot produce a sharp resonant band, a novel S-slot DGS is presented. Compared ... In order to solve the problem that the quality factor ( Q factor) of the conventional defected ground structure (DGS)is not high and cannot produce a sharp resonant band, a novel S-slot DGS is presented. Compared with the conventional DGS, the proposed S-slot DGS has a much higher Q factor, a quite simpler layout and a steeper band rejection. Its equivalent circuit model is extracted by analyzing the transfer characteristics, and design parameters are calculated according to the deducted equations. Characteristics of this type of DGS are investigated with variable dimension parameters and an experiential method for the design of the S-slot DGS is summarized. Finally, a sample of a compact S-slot DGS unit resonated at 4. 64 GHz is fabricated. Its Q factor is as high as 39. 66 and its size is only 5.00 mm × 1.40 mm, with a steep resonant band and a low insertion-loss passband. The measured results show a good agreement with simulation, which demonstrates the applicability of the S-slot DGS in practical engineering. 展开更多
关键词 S-slot defected ground structure (DGS) quality factor
在线阅读 下载PDF
Modeling and Analysis of Mechanical Quality Factor of the Resonator for Cylinder Vibratory Gyroscope 被引量:5
10
作者 XI Xiang WU Xuezhong +1 位作者 WU Yulie ZHANG Yongmeng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第1期180-189,共10页
Mechanical Quality factor(Q factor) of the resonator is an important parameter for the cylinder vibratory gyroscope(CVG). Traditional analytical methods mainly focus on a partial energy loss during the vibration p... Mechanical Quality factor(Q factor) of the resonator is an important parameter for the cylinder vibratory gyroscope(CVG). Traditional analytical methods mainly focus on a partial energy loss during the vibration process of the CVG resonator, thus are not accurate for the mechanical Q factor prediction. Therefore an integrated model including air damping loss, surface defect loss, support loss, thermoelastic damping loss and internal friction loss is proposed to obtain the mechanical Q factor of the CVG resonator. Based on structural dynamics and energy dissipation analysis, the contribution of each energy loss to the total mechanical Q factor is quantificationally analyzed. For the resonator with radius ranging from 10 mm to 20 mm, its mechanical Q factor is mainly related to the support loss, thermoelastic damping loss and internal friction loss, which are fundamentally determined by the geometric sizes and material properties of the resonator. In addition, resonators made of alloy 3J53 (Ni42CrTiA1), with different sizes, were experimentally fabricated to test the mechanical Q factor. The theoretical model is well verified by the experimental data, thus provides an effective theoretical method to design and predict the mechanical Q factor of the CVG resonator. 展开更多
关键词 mechanical quality factor cylinder vibratory gyroscope energy loss
在线阅读 下载PDF
Ultrahigh accelerating gradient and quality factor of CEPC 650 MHz superconducting radio-frequency cavity 被引量:3
11
作者 Peng Sha Wei-Min Pan +9 位作者 Song Jin Ji-Yuan Zhai Zheng-Hui Mi Bai-Qi Liu Chao Dong Fei-Si He Rui Ge Liang-Rui Sun Shi-Ao Zheng Ling-Xi Ye 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第10期33-40,共8页
Two 650 MHz single-cell superconducting radio-frequency(SRF)cavities used for the Circular Electron Positron Collider(CEPC)were studied to achieve a high accelerating gradient(E_(acc))and high intrinsic quality factor... Two 650 MHz single-cell superconducting radio-frequency(SRF)cavities used for the Circular Electron Positron Collider(CEPC)were studied to achieve a high accelerating gradient(E_(acc))and high intrinsic quality factor(Q_(0)).The 650 MHz single-cell cavities were subjected to a combination of buffered chemical polishing(BCP)and electropolishing(EP),and their E_(acc) exceeded40 MV/m.Such a high E_(acc) may result from the cold EP with more uniform removal.BCP is easy,cheap,and rough,whereas EP is complicated,expensive,and precise Therefore,the combination of BCP and EP investigated in this study is suitable for surface treatments of mass SRF cavities.Medium temperature(mid-T)furnace baking was also conducted,which demonstrated an ultrahigh Q_(0) of 8×10^(10) at 22 MV/m for both cavities,and an extremely low BCS resistance(R_(BCS))of~1.0 nΩwas achieved a2.0 K. 展开更多
关键词 SRF cavity Accelerating gradient quality factor ELECTROPOLISHING Vertical test
在线阅读 下载PDF
Measurement of the cavity-loaded quality factor in superconducting radio-frequency systems with mismatched source impedance 被引量:2
12
作者 Jin-Ying Ma Cheng-Ye Xu +12 位作者 An-Dong Wu Guo-Dong Jiang Yue Tao Zong-Heng Xue Long-Bo Shi Tian-Cai Jiang Zheng-Long Zhu Zi-Qin Yang Zheng Gao Lie-Peng Sun Gui-Rong Huang Feng Qiu Yuan He 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第8期12-23,共12页
The accurate measurement of parameters such as the cavity-loaded quality factor(Q_(L))and half bandwidth(f_(0.5))is essential for monitoring the performance of superconducting radio-frequency cavities.However,the conv... The accurate measurement of parameters such as the cavity-loaded quality factor(Q_(L))and half bandwidth(f_(0.5))is essential for monitoring the performance of superconducting radio-frequency cavities.However,the conventional"field decay method"employed to calibrate these values requires the cavity to satisfy a"zero-input"condition.This can be challenging when the source impedance is mismatched and produce nonzero forward signals(V_(f))that significantly affect the measurement accuracy.To address this limitation,we developed a modified version of the"field decay method"based on the cavity differential equation.The proposed approach enables the precise calibration of f_(0.5) even under mismatch conditions.We tested the proposed approach on the SRF cavities of the Chinese Accelerator-Driven System Front-End Demo Superconducting Linac and compared the results with those obtained from a network analyzer.The two sets of results were consistent,indicating the usefulness of the proposed approach. 展开更多
关键词 Loaded quality factor Field decay method Superconducting cavity MISMATCH Calibration Cavity differential equation Measurement Accelerator-driven system
在线阅读 下载PDF
Standing wave drift of hemispherical resonator with quality factor non-uniformity under a ring electrode excitation 被引量:2
13
作者 Yan HUO Zeyu WANG +3 位作者 Shunqing REN Zhennan WEI Guoxing YI Changhong WANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2022年第1期160-172,共13页
Hemispherical Resonator Gyroscope(HRG)is a classical high precision Coriolis Vibration Gyroscope(CVG),which performs attitude estimation of carrier by detecting the precession of standing wave of resonator,thus,the dr... Hemispherical Resonator Gyroscope(HRG)is a classical high precision Coriolis Vibration Gyroscope(CVG),which performs attitude estimation of carrier by detecting the precession of standing wave of resonator,thus,the drift of standing wave of resonator has a great influence on the output accuracy of gyroscope,where the quality factor non-uniformity of resonator is one of main error sources.Ring electrode is a classical excitation structure of HRG because the standing wave can precess freely under its excitation,which makes the gyroscope have more accurate scale factor,larger measurement range and better dynamic characteristics.In this paper,the equations of motion of an ideal resonator excited by a ring electrode are derived by the elastic thin shell theory and Lagrange mechanical principle,then the corresponding equivalent mechanical model is established.According to the“average method”,it can be seen that the ideal resonator excited by the ring electrode works in integral mode,and any position in the circumferential direction of resonator can be a working point,which means that the quality factor non-uniformity has a great effect on the drift of standing wave.Therefore,the equations of motion of resonator with quality factor non-uniformity under the ring electrode excitation are deduced by the equivalent mechanical model,and the drift model of standing wave is established by the“average method”,it can be found that both the amplitude of quality factor non-uniformity and angle between the“inherent damping axis”and antinode axis of standing wave can affect the drift rate of standing wave.Moreover,the drift model indicates that if the input angular rate does not reach the threshold,the precession angular rate of standing wave will appear“self-locking”phenomenon,that is,the gyroscope will lose the integral effect. 展开更多
关键词 Hemispherical resonator Theory of elastic thin shell Motion equations Average method quality factor non-uniformity “Self-locking”phenomenon
原文传递
Joint inversion method for interval quality factor based on amplitude and phase information 被引量:2
14
作者 Cao Dan-Ping Li Yue +1 位作者 Sun Wen-Guo Liang Kai 《Applied Geophysics》 SCIE CSCD 2019年第2期199-208,253-254,共12页
Estimating the quality factor Q accurately signifi cantly improves the seismic data resolution and reservoir characterization.The commonly used log-spectral ratio method uses least-squares fi tting to obtain Q values ... Estimating the quality factor Q accurately signifi cantly improves the seismic data resolution and reservoir characterization.The commonly used log-spectral ratio method uses least-squares fi tting to obtain Q values and involves only the amplitude information of seismic data while neglecting phase information.This paper proposes a joint interval Q inversion method based on the spectral ratio method and employs both amplitude and phase information to improve the accuracy.Based on the assumption that Q is independent of frequency,the nonlinear relation between the Q value and the two types of information is jointly used to construct an objective function,which clarifies the quantitative relation between amplitude spectrum,phase information,and Q value.The interval Q value can be inverted by calculating the minimum value of the objective function.The model test exhibits that the proposed method has higher precision and stability than the spectral ratio method;furthermore,the application to field data demonstrates that accurate Q inversion results are consistent with reservoir characteristics. 展开更多
关键词 viscoelastic medium quality factor AMPLITUDE PHASE
在线阅读 下载PDF
Revisiting the period and quality factor of the Chandler wobble and its possible geomagnetic jerk excitation 被引量:1
15
作者 Yachong An Hao Ding 《Geodesy and Geodynamics》 CSCD 2022年第5期427-434,共8页
The period and quality factor of the Chandler wobble(CW)are useful for constraining the Earth’s internal structure properties,such as the mantle elasticity.It has been shown that the CW is mainly excited by a combina... The period and quality factor of the Chandler wobble(CW)are useful for constraining the Earth’s internal structure properties,such as the mantle elasticity.It has been shown that the CW is mainly excited by a combination of atmospheric and oceanic processes;hence based on a deconvolution method,we can remove them from the excitation sequence of the CW to estimate its period P and quality factor Q.We finally re-estimate P=432.3±0.8 days and Q=85±15 for the CW.Based on those two estimates,we investigate the relationship between the geomagnetic jerks and the excitation sequences of the CW.The geomagnetic jerks or jerk bounds are well consistent with the sudden changes of the excitation sequences of the CW.This demonstrates that the geomagnetic jerks could be a possible excitation source of the CW.It is crucial for understanding the excitation of the CW and for deeper geophysical insights into the geomagnetic jerks. 展开更多
关键词 Chandler wobble quality factor De-convolution Geomagnetic jerks
原文传递
Influence of the quality factor on simulated seismic waves:A case study of the 1994 Northridge earthquake 被引量:1
16
作者 Qingpei Zeng Xiangchao Wang Jinting Wang 《Earthquake Science》 2022年第5期329-342,共14页
In numerical simulations of ground motion,the constant quality factor Q of a viscoelastic medium can be determined using the time-domain constitutive approximation method of the generalized standard linear solid(GSLS)... In numerical simulations of ground motion,the constant quality factor Q of a viscoelastic medium can be determined using the time-domain constitutive approximation method of the generalized standard linear solid(GSLS)model.This study introduces a numerical seismic wavefield simulation method which combines the spectral element method with the constant-Q model.The method is used to simulate the seismic wavefield of the 1994 Northridge earthquake.The optimal attenuation coefficient for the simulated seismic waves in this study area is determined empirically based on a quantitative analysis of the deviation curve.Further,the effect of the quality factor on the simulated wavefield are analyzed according to the site characteristics of each seismic station.The quality factor shows a variable effect on the different frequency components of the simulated wavefield.The effect of the quality factor also varies with the characteristic parameters of each seismic station site,such as site velocity structure,fault distance,and azimuth angle. 展开更多
关键词 ground motion simulation quality factor VISCOELASTICITY SLS spectral element method
在线阅读 下载PDF
A WSN Node Fault Diagnosis Model Based on BRB with Self-Adaptive Quality Factor 被引量:1
17
作者 Guo-Wen Sun Gang Xiang +3 位作者 Wei He Kai Tang Zi-Yi Wang Hai-Long Zhu 《Computers, Materials & Continua》 SCIE EI 2023年第4期1157-1177,共21页
Wireless sensor networks (WSNs) operate in complex and harshenvironments;thus, node faults are inevitable. Therefore, fault diagnosis ofthe WSNs node is essential. Affected by the harsh working environment ofWSNs and ... Wireless sensor networks (WSNs) operate in complex and harshenvironments;thus, node faults are inevitable. Therefore, fault diagnosis ofthe WSNs node is essential. Affected by the harsh working environment ofWSNs and wireless data transmission, the data collected by WSNs containnoisy data, leading to unreliable data among the data features extracted duringfault diagnosis. To reduce the influence of unreliable data features on faultdiagnosis accuracy, this paper proposes a belief rule base (BRB) with a selfadaptivequality factor (BRB-SAQF) fault diagnosis model. First, the datafeatures required for WSN node fault diagnosis are extracted. Second, thequality factors of input attributes are introduced and calculated. Third, themodel inference process with an attribute quality factor is designed. Fourth,the projection covariance matrix adaptation evolution strategy (P-CMA-ES)algorithm is used to optimize the model’s initial parameters. Finally, the effectivenessof the proposed model is verified by comparing the commonly usedfault diagnosis methods for WSN nodes with the BRB method consideringstatic attribute reliability (BRB-Sr). The experimental results show that BRBSAQFcan reduce the influence of unreliable data features. The self-adaptivequality factor calculation method is more reasonable and accurate than thestatic attribute reliability method. 展开更多
关键词 Self-adaptive quality factor belief rule base wireless sensor networks fault diagnosis
在线阅读 下载PDF
Relationship between the Water Body Chlorophylla and Water Quality Factors of Wetlands Baiguishan Reservoir 被引量:1
18
作者 SHE Qiu-sheng TIAN Xun WANG Guo-zhen JI Xiao-cun LI Jiu-xuan ZHAO Zhen 《Agricultural Science & Technology》 CAS 2011年第4期581-583,591,共4页
[Objective] The aim was to explore the relationship between water body Chlorophyll-a and water quality factors of wetlands Baiguishan reservoir.[Method] Chlorophyll-a and water quality factors of water quality of Wetl... [Objective] The aim was to explore the relationship between water body Chlorophyll-a and water quality factors of wetlands Baiguishan reservoir.[Method] Chlorophyll-a and water quality factors of water quality of Wetlands BaiGuishan Reservoir was studied,the analysis of the relationship on water quality of Wetlands Baiguishan Reservoir was made by use of trophic status indices and SPSS17.0 statistical analysis.[Result] Total phosphorus was an important factor of influence Chlorophyll-a in reservoir,water body had slight eutrophication phenomenon in reservoir of July to October in 2010.[Conclusion] Comprehensive management should be strengthened so as to improve the water quality of Baiguishan wetland. 展开更多
关键词 Wetlands Baiguishan Reservoir CHLOROPHYLL-A Water quality factors RELATIONSHIP
在线阅读 下载PDF
Bulk GaN-based SAW resonators with high quality factors for wireless temperature sensor
19
作者 Hongrui Lv Xianglong Shi +6 位作者 Yujie Ai Zhe Liu Defeng Lin Lifang Jia Zhe Cheng Jie Yang Yun Zhang 《Journal of Semiconductors》 EI CAS CSCD 2022年第11期78-83,共6页
Surface acoustic wave(SAW)resonator with outstanding quality factors of 4829/6775 at the resonant/anti-resonant frequencies has been demonstrated on C-doped semi-insulating bulk GaN.The impact of device parameters inc... Surface acoustic wave(SAW)resonator with outstanding quality factors of 4829/6775 at the resonant/anti-resonant frequencies has been demonstrated on C-doped semi-insulating bulk GaN.The impact of device parameters including aspect ratio of length to width of resonators,number of interdigital transducers,and acoustic propagation direction on resonator performance have been studied.For the first time,we demonstrate wireless temperature sensing from 21.6 to 120℃ with a stable temperature coefficient of frequency of–24.3 ppm/℃ on bulk GaN-based SAW resonators. 展开更多
关键词 surface acoustic wave RESONATOR gallium nitride quality factor temperature sensor
在线阅读 下载PDF
Improved Design and Modeling of Micromachined Tuning Fork Gyroscope Characterized by High Quality Factor
20
作者 Ji-Ping Guan Xiao-Ming Liu 《Journal of Electronic Science and Technology》 CAS 2010年第3期280-286,共7页
This paper proposes an improved design of micromachined tuning fork gyroscope (M-TFG) to decouple the cross talk between driving and sensing directions better and to increase resolution. By employing dual-folds spri... This paper proposes an improved design of micromachined tuning fork gyroscope (M-TFG) to decouple the cross talk between driving and sensing directions better and to increase resolution. By employing dual-folds spring suspension, the drive mode and the sense mode are mechanically decoupled. Through careful layout design of the location of the dual-folds spring suspension and the drive combs, the mechanical coupling effect is further decreased by isolating the unwanted excitation from detection. The quality factor investigation demonstrates that high quality factor can be attained by using this structure, which can bring in accurate resolution. As a result, this design has the potential to accomplish low bias drift and accurate resolution for initial level applications. 展开更多
关键词 Decouple GYROSCOPE micromachined quality factor tuning fork.
在线阅读 下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部