期刊文献+
共找到12,035篇文章
< 1 2 250 >
每页显示 20 50 100
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
1
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
在线阅读 下载PDF
Development and Experimental Study of Air Source Heat Pump Water Heater 被引量:2
2
作者 李海峰 蔡正云 《Meteorological and Environmental Research》 CAS 2010年第2期100-102,共3页
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul... The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water. 展开更多
关键词 Air source Heat pump water heater China
在线阅读 下载PDF
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
3
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
Numerical and Experimental Study on Dynamic Performance of Heat Pump Water Heater with Electronic Expansion Valve
4
作者 Liang Zhang Xianmin Guo Weiguo Li Weihua Wang 《Journal of Energy and Power Engineering》 2012年第10期1582-1588,共7页
A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capac... A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%. 展开更多
关键词 Heat pump water heater electronic expansion valve experimental investigation simulation.
在线阅读 下载PDF
Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens 被引量:4
5
作者 LIU Zhong-bing,ZHANG Ling,YANG Zhang,XU Ming,HAN Tian-he(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期131-135,共5页
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff... A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient. 展开更多
关键词 THERMOELECTRIC heat pump KITCHENS EXHAUST water HEATER COEFFICIENT of performance
在线阅读 下载PDF
Experimental study of air source heat pump water heater:Energy,exergy,and entransy analysis
6
作者 Fang Ruan Saisai Xu +2 位作者 Dingye Qin Shun Li Pengxu Chen 《Energy and Built Environment》 2025年第2期187-200,共14页
With the continuous progress of urbanization,building energy consumption is increasing dramatically.At present,energy consumption caused by air conditioning accounts for a half in typical building energy consumption i... With the continuous progress of urbanization,building energy consumption is increasing dramatically.At present,energy consumption caused by air conditioning accounts for a half in typical building energy consumption in China.Using exergy and entransy analysis,this paper experimentally studies the thermal performance of an air source heat pump water heater and its components under different meteorological conditions.This paper,for the first time,introduces the dimensionless number of entransy dissipation ratio(EDR),namely the percentage of a component’s entransy dissipation into the entire system.The findings indicate that with the increase in air temperature,the heat production,the EDR of condenser and evaporator,and the exergy efficiency of condenser and compressor increase while the exergic efficiency of evaporator and throttle valve decrease.In the case of increased air flow rate,the heat production and exergy destruction of water heater as well as the EDR of evaporator are enhanced,while the exergy efficiency of evaporator,compressor and throttle and the EDR of condenser decrease,with the exergy efficiency of the throttle remaining the highest.The irreversibility rates of components are affected by change in the relative humidity of air,which is specified as follows:The percentage range of irreversibility rates for compressor,condenser,throttle and evaporator is 11.5–16%,37–45%,6.8–11.5%and 32–41%,respectively. 展开更多
关键词 Weather conditions Entransy dissipation EDR Exergy analysis Air source heat pump water heater
在线阅读 下载PDF
基于Pumplinx的核电站给水泵三维流场仿真
7
作者 段程豫 《价值工程》 2026年第2期106-108,共3页
本文基于PumpLinx平台构建核电站给水泵全三维瞬态流场模型,采用分层网格与SST k-ω湍流模型耦合求解,揭示设计工况及事故序列下多物理场耦合机制。研究表明:外特性曲线在特定流量比时效率达极值,超流量工况扬程断裂源于叶轮前缘空化阻... 本文基于PumpLinx平台构建核电站给水泵全三维瞬态流场模型,采用分层网格与SST k-ω湍流模型耦合求解,揭示设计工况及事故序列下多物理场耦合机制。研究表明:外特性曲线在特定流量比时效率达极值,超流量工况扬程断裂源于叶轮前缘空化阻塞;子午面分析显示空化核心区集中于诱导轮吸力面及轮缘间隙,与低压区显著重合;高湍流动能分布于级间过渡段,主因几何失配诱发流动分离。研究成果为核电站多级给水泵的空化抑制与结构优化提供了高置信度仿真设计依据。 展开更多
关键词 给水泵 pumplinx 空化阻塞 子午面流场 气相分布 湍流模型
在线阅读 下载PDF
Performance analysis of air-water dual source heat pump water heater with heat recovery 被引量:9
8
作者 CHEN ZeShao TAO WenQuan +1 位作者 ZHU YanWen HU Peng 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第8期2148-2156,共9页
A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre... A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value. 展开更多
关键词 heat pump water heater waste heat recovery dual source heat pump correspondence analysis method performance analysis
原文传递
Influence of Valve's Characteristic on Total Performance of Three Cylinders Internal Combustion Water Pump 被引量:14
9
作者 ZHANG Hongxin ZHANG Tiezhu WANG Weichao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2009年第1期91-96,共6页
Intenal combustion pump (ICP) is a new type power device turning the thermal energy from fuel combustion into fluid pressure energy. Three cylinders prototype has just been developed. The study on the influence of v... Intenal combustion pump (ICP) is a new type power device turning the thermal energy from fuel combustion into fluid pressure energy. Three cylinders prototype has just been developed. The study on the influence of valve's characteristic on ICP's total performance will found the base for its optimum design. Based on the theoretical and testing fruits of single cylinder prototype, the performance of the valves and complete appliance of the latest is simulated. When the natural frequency of valves is approximately to the round number times of the working frequency, volumetric efficiency is seriously low. The nominal rotational speed of the prototype is nearly to the speed where the volumetric efficiency is lowest, which is harmful to the normal work of ICP, so further structure optimization of valves should be carried out. The change of volumetric efficiency has great influence on the fuel consumption rate, output flow, effective thermal efficiency, effective power, and so on, but little on output pressure. 展开更多
关键词 internal combustion engine water pump VALVE model performance
在线阅读 下载PDF
Pressure fluctuation and its influencing factors in circulating water pump 被引量:13
10
作者 代翠 孔繁余 董亮 《Journal of Central South University》 SCIE EI CAS 2013年第1期149-155,共7页
In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbul... In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted. 展开更多
关键词 circulating water pump turbulence model sampling frequency sampling time pressure fluctuation
在线阅读 下载PDF
DYNAMICS MODEL AND SIMULATION OF FLAT VALVE SYSTEM OF INTERNAL COMBUSTION WATER PUMP 被引量:39
11
作者 Zhang Hongxin Zhang Tiezhu +2 位作者 Wang Yushun Zhao Hong Huo Wei 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第3期411-414,共4页
The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase s... The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase step when outlet valve or inlet valve opens, but is more gently in other time; The volume efficiency is influenced by the output pressure slightly, and decreases as the working rotational speed increases; When the inherent frequency of the valves is integer multiple of the working frequency, the volume efficiency of system will decrease evidently. 展开更多
关键词 Check valve Simulation Dynamics model Internal combustion water pump(ICWP)
在线阅读 下载PDF
Studies on the changes of West Lake's zoobenthic communites after Qiantang River water was pumped into it 被引量:5
12
作者 虞左明 严力蛟 吴洁 《Journal of Zhejiang University Science》 CSCD 2002年第1期118-124,共7页
During Jan.1995 to Dec.1996, monthly investigations on the zoobenthic communities of West Lake, samples were collected from six sampling stations. A total of 26 species of macrozoobenthos were identified. The seasonal... During Jan.1995 to Dec.1996, monthly investigations on the zoobenthic communities of West Lake, samples were collected from six sampling stations. A total of 26 species of macrozoobenthos were identified. The seasonal changes in density and biomass of zoobenthos in this lake were analyzed. The annual mean densities were 980~2751 ind/m\+2 and mean biomass was 19.69-122.80 g/m\+2. The densities in winter and early spring were higher than those in summer and autumn. Comparative study of theprevious data (1982 to 1983) collected by the authors, showed that the succession of zoobenthic communities, dominated by \%Procludius choreus\% in density and \%Bellamya purificata\% in biomass, had been occurred in Xiaonan sub\|lake after Qiantang River water was drawn into it; and that the species and biomass of zoobenthos were then increased and the density was decreased. In other sub\|lakes, the dominant species were \%Limnodrilus hoffmeisteri\% and \%Tokunagayusurika akamusi \%in density and \%Branchiura sowerbyi\% and \%Tokunagayusurika akamusi \%in biomass. The water quality was bad in these sub\|lakes because these dominant species are indicators of eutrophication. According to the Margalef index and Goodnight index, West Lake is still an eutrophic lake. Only the water quality of Xiaonan sub\|lake was improved after water drawn from the Qiantang River was introduced into it. 展开更多
关键词 ZOOBENTHOS EUTROPHICATION water pumped West Lake environmental engineering
在线阅读 下载PDF
Feasibility Analysis of Back-Pressure Steam Feeding Water Pump for Direct Air-Cooled Unit 被引量:1
13
作者 Zhao Xiaodong Wang Meng +2 位作者 Du Xiaoze Yang Lijun Yang Yongping 《Electricity》 2013年第1期31-35,共5页
As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introd... As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified. 展开更多
关键词 air-cooled back-pressure steam turbine steam feed water pump variable condition
在线阅读 下载PDF
Design on Vibration Monitoring and Fault Diagnosis System of Large Water Pump Motor 被引量:2
14
作者 WEI Xieben LU Xujin +1 位作者 LI Tongbin CHEN Shuqin 《International Journal of Plant Engineering and Management》 2021年第2期118-128,共11页
Large water pump motor,whose operation decides the reliability of the whole production line,plays a very important role.Therefore,its online condition monitoring can help companies better know its operation,process fa... Large water pump motor,whose operation decides the reliability of the whole production line,plays a very important role.Therefore,its online condition monitoring can help companies better know its operation,process fault analysis and protection.The essay mainly studies and designs large water pump motor′s real time vibration monitoring and fault diagnosis system.The essay completes the systems project design,the establishment of the system and performance test.Eddy-currentsensor,XM-120 vibration module,XM-320 axial translation module,XM-362 temperature module,XM-360 process amount module and XM-500 gateway module are used to measure the axial vibration and displacement of main motors.Laboratory tests prove that the system can meet the requirements of motor vibration monitoring. 展开更多
关键词 large water pump motor vibration monitoring real-time monitoring fault diagnosis TEST
在线阅读 下载PDF
Study on corrosion behavior of heat exchanger in water source heat pump
15
作者 刘作华 龙洋 +2 位作者 李百战 丁勇 周小霞 《化工进展》 EI CAS CSCD 北大核心 2010年第S1期695-698,共4页
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T... Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value. 展开更多
关键词 water source HEAT pump water quality RIVER water corrosion
在线阅读 下载PDF
Assessment of the Rural Water Supply Potential by Mechanical Wind Pumping Around the Floodplains of Lake Chad
16
作者 DieudonnéKaoga Kidmo Bachirou Bogno +1 位作者 Kodji Deli Michel Aillerie 《Energy Engineering》 EI 2021年第4期931-945,共15页
In the present work,an assessment of the rural water supply potential by mechanical wind pumping around the floodplains of Lake Chad has been considered.Inside the floodplains around Lake Chad,available surface water ... In the present work,an assessment of the rural water supply potential by mechanical wind pumping around the floodplains of Lake Chad has been considered.Inside the floodplains around Lake Chad,available surface water is largely contaminated and represents health hazards to populations.Access to underground and clean water has increasingly become rare.Moreover,clean water scarcity has led to conflict and territorial pressures,which are contributing factors to poverty in the considered area.Four localities,Baga,Baga-Sola,Makari and Nguigmi,respectively,in Nigeria,Chad,Cameroon and Niger have been selected inside the floodplains around Lake Chad,to evaluate the potential of wind power and prospects of windmills development to provide safe drinking-water supply,livestock watering and small-scale irrigation.Long-term satellite-derived data,obtained through the Prediction of Worldwide renewable Energy Resources have been considered suitable and viable alternative to missing site-specific data from ground stations.Windmill of Multi-blade driven piston pump is the preferred water pumping option for this study because of its higher overall system efficiency.The results of this study indicate that mean wind speeds,at 10 m height above ground level,are 4.64 m/s for Baga,4.76 m/s for Baga-Sola,4.32 m/s for Makari and 4.44 m/s for Nguigmi.In addition,wind speeds for Baga,for instance,are in the range of 2.5–10 m(working range of a wind pump),at 10,15,20 and 25 m height agl,for 79.64,82.80,84.79,and 86.19 per cent of the time.Corresponding values for Baga-Sola,Makari and Nguigmi are in the range of 80.50–87.76 per cent,76.86–85,58 per cent,77.92–86.21 per cent,respectively.For a Windmill with a 2 m-blade,a 25 m-height tower and considering a total dynamic head of 30 m,average monthly discharges for the dry season are 1,330,1,374,1,200 and 1,199 m3,respectively for Baga,Baga-Sola,Makari and Nguigmi.Furthermore,corresponding costs of water are 9.53,9.23,10.56 and 10.57 XAF/m3,for Baga,Baga-Sola,Makari and Nguigmi,in that order. 展开更多
关键词 Wind energy WINDMILL water pumping lake chad
在线阅读 下载PDF
A Lightweight Electronic Water Pump Shell Defect Detection Method Based on Improved YOLOv5s
17
作者 Qunbiao Wu Zhen Wang +2 位作者 Haifeng Fang Junji Chen Xinfeng Wan 《Computer Systems Science & Engineering》 SCIE EI 2023年第7期961-979,共19页
For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surf... For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surface defect detection,a lightweight detection method based on an improved YOLOv5s method is proposed to replace the traditional manual detection methods.In this method,the MobileNetV3 module replaces the backbone network of YOLOv5s,depth-separable convolution is introduced,the parameters and calculations are reduced,and CIoU_Loss is used as the loss function of the boundary box regression to improve its detection accuracy.A dataset of electronic pump shell defects is established,and the performance of the improved method is evaluated by comparing it with that of the original method.The results show that the parameters and FLOPs are reduced by 49.83%and 61.59%,respectively,compared with the original YOLOv5s model,and the detection accuracy is improved by 1.74%,which is an indication of the superiority of the improved method.To further verify the universality of the improved method,it is compared with the results using the original method on the PASCALVOC2007 dataset,which verifies that it yields better performance.In summary,the improved lightweight method can be used for the real-time detection of electronic water pump shell defects. 展开更多
关键词 Electronic water pump shell surface defect detection lightweight network loss function
在线阅读 下载PDF
Comprehensive Study,Design and Economic Feasibility Analysis of Solar PV Powered Water Pumping System
18
作者 K.Karthick K.Jaiganesh S.Kavaskar 《Energy Engineering》 EI 2021年第6期1887-1904,共18页
The energy efficient product can be operated with longer duration.They offer wonderful solutions compared to other conventional water pumping system as it needs less maintenance,simple in installation,zero fuel cost,l... The energy efficient product can be operated with longer duration.They offer wonderful solutions compared to other conventional water pumping system as it needs less maintenance,simple in installation,zero fuel cost,longer operating life,highly reliable and free from production of greenhouse gases.In this paper we analyzed the different topologies of DC–DC converter in terms of their operating region of MPPT,quality of input and output currents.We discussed the MPPT algorithms to address partial shading effects in SPV array,present state of the technology,factors affecting the performance of the system,efficiency improvements and identified the research gaps.Also,the economic feasibility analysis has been done for the real time scenario using the Homer Pro software.The estimation of total dynamic head and horse power calculation has been done to decide the total load capacity.The economic analysis results such as cumulative cash flow over project lifetime of 25 years are presented.It is observed that the capital investment requirement is$7,425 for installing Fronius PV system that has a nominal capacity of 2.47 kW and annualized savings will be$134.93.In the long-term perspective,the return on investment is−2.18%as per the present tariff plan. 展开更多
关键词 DC-DC converter economic feasibility analysis MPPT solar photo voltaic solar pumps water pumping system
在线阅读 下载PDF
Optimised Design and Analysis of Solar Water Pumping Systems for Pakistani Conditions
19
作者 Usman Ashraf M. Tariq Iqbal 《Energy and Power Engineering》 2020年第10期521-542,共22页
This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakis... This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakistan. The design, sizing, cost analysis and steady state analysis of the proposed systems were done in HOMER and dynamic analysis of the designed system with battery bank was performed in MATLAB/Simulink. The simulations performed in HOMER involved proper mapping of the loads which helped to evaluate the PV panel requirement, inverter rating, batteries (in case of battery based solution), modeling of water tank as a deferrable load (in case of solution based of water tank) and detailed cost analysis for a life time of 25 years. To verify the design of the solar water pumping system with battery bank, a simulation in MATLAB/Simulink for study of dynamic behavior of the overall system was performed which involved mathematical modeling of a PV panel, buckboost converter, inverter, battery bank and motor/pump, a perturb and observe maximum power point tracking algorithm based control system. Analysis was conducted based on the economic results that indicate designed solar water pumping system with water tank would be a cheaper solution as compared to solar water pumping system with a battery bank. This work can be taken as a case study for the understanding and optimized designs of solar water pumping system with battery bank and with cylindrical tank in Pakistani conditions. 展开更多
关键词 Solar water pumping System MATLAB Simulink Solar Energy HOMER Manual Formulation Methods Computers Based Method Steady State Modeling Dynamic Modeling Solar Panels
在线阅读 下载PDF
Application of Solar Photovoltaic Water Pumping System in Hainan Agriculture
20
作者 Xiangchun YU Qingqing LIN +1 位作者 Xuedong ZHOU Zhibin YANG 《Asian Agricultural Research》 2013年第12期104-106,110,共4页
With radical socio-economic development and strengthening of regulation of agricultural industrial structure in Hainan Province,fresh water resource becomes increasingly insufficient.Existing water-saving facilities a... With radical socio-economic development and strengthening of regulation of agricultural industrial structure in Hainan Province,fresh water resource becomes increasingly insufficient.Existing water-saving facilities and measures are unable to promote sustainable and stable development of local economy.This needs modern irrigation method.Solar photovoltaic water pumping system is necessary and feasible in Hainan agriculture,and will have directive significance for Hainan Province developing photovoltaic agriculture. 展开更多
关键词 HAINAN AGRICULTURE SOLAR ENERGY PHOTOVOLTAIC pumpi
在线阅读 下载PDF