Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,i...Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,in certain regions,the installation of buried pipes for heat exchangers may be complicated,and these pipes may not always serve as efficient low-temperature heat sources for the heat pumps of the system.To address this issue,the current study explored the use of solar-energy-collecting equipment to supplement buried pipes.In this design,both solar energy and geothermal energy provide low-temperature heat to the heat pump.First,a simulation model of a solar‒ground source heat pump coupling system was established using TRNSYS.The accuracy of this model was validated through experiments and simulations on various system configurations,including varying numbers of buried pipes,different areas of solar collectors,and varying volumes of water tanks.The simulations examined the coupling characteristics of these components and their influence on system performance.The results revealed that the operating parameters of the system remained consistent across the following configurations:three buried pipes,burial depth of 20 m,collector area of 6 m^(2),and water tank volume of 0.5 m^(3);four buried pipes,burial depth of 20 m,collector area of 3 m^(2),and water tank volume of 0.5 m^(3);and five buried pipes with a burial depth of 20 m.Furthermore,the heat collection capacity of the solar collectors spanning an area of 3 m^(2)was found to be equivalent to that of one buried pipe.Moreover,the findings revealed that the solar‒ground source heat pump coupling system demonstrated a lower annual cumulative energy consumption compared to the ground source heat pump system,presenting a reduction of 5.31%compared to the energy consumption of the latter.展开更多
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of...A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.展开更多
This study introduces a novel artificial heating technique aimed at addressing frost heave issues in embankments on frozen ground,offering a sustainable solution.Initial evaluations assessed various heating systems,in...This study introduces a novel artificial heating technique aimed at addressing frost heave issues in embankments on frozen ground,offering a sustainable solution.Initial evaluations assessed various heating systems,including boilers,heat pumps,solar heaters,and electric heaters,focusing on their thermal performance and applicability.The study subsequently designed and implemented a direct-expansion ground source heat pump(DX-GSHP)system as the primary heat source for embankment warming.Rigorous testing confirmed the DX-GSHP system's ability to maintain a heat-supply temperature above 40℃ and a heat-absorption temperature below -3.5℃,effectively extracting geothermal energy for transfer to the topsoil layers.With a demonstrated coefficient of performance(COP)of 3.49,the DX-GSHP system not only proves its energy efficiency but also suggests a potential role in reducing the strain on electricity supply systems.Installation of DX-GSHPs,with heating capacities ranging from 1.0 to 2.0 kW and spaced at intervals of 2.0-4.0 m,provides a rapid thermal response to frost heave in singletrack railway embankments,thereby potentially mitigating frost-induced damage in cold climate regions.展开更多
In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model wi...In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.展开更多
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho...To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.展开更多
The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of buildin...The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of building air conditioning load were considered.The results,compared with the constant flow operation,indicate that the influence on the variations of porosity,hydraulic conductivity and confined water head is decreased by 48%,51% and 71%,respectively,under variable flow operation.The security of variable flow operation is superior to that of constant flow.It is also concluded that the climate region and function of the buildings are primary factors which affect the suitability of variable flow operation in GWSHP.展开更多
Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is fo...Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.展开更多
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ...An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.展开更多
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is...The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulati...This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP.展开更多
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr...To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.展开更多
Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditio...Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%.展开更多
The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the Eur...The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the European project "Integration of Geothermal Energy Into Industrial Application - IGEIA", project number EIE 06/001, supported by the Intelligent Energy for Europe, IEE, of EACI, European Commission. In general for supermarkets installed in single buildings, the building envelope has higher rates of envelope areas per indoor air volume. In Portugal this fact produces high need of heating during the winter season and high cooling needs during the summer season. Inside the building there are strong internal heat loads produced by high densities of lights and equipments. However these internal loads are not distributed uniformly. There are some areas with high production of heat but there are others with production of cooling. Therefore the acclimatization of this kind of buildings is not so easy and the balance of heating and cooling needs is depending of different parameters which should be well evaluated. The energy consummation of the cold display cases and deep freezers in market area and storage is also very high. The different energy needs could be studied in an integrated way and could be partially satisfied by geothermal energy using ground source heat pumps. At the same time the boreholes could be used as an energy reservoir increasing the efficiency of whole system. Four different climatic zones in Portugal were selected, (north coast, interior north, south coast and interior south) using the same system. The results of the study show that the all energy needs can by partially satisfied by geothermal energy but they need to be integrated to increase the global efficiency. The paper shows that the geothermal energy can be an attractive application for the supermarkets in Portugal if the energy solution is studied in an integrated way and if it is also considered as a cost the emissions of CO2 avoid by the new system.展开更多
According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP...According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP) were established in Baotou plain. The factor weights were determined by using analytic hierarchy process,and the comprehensive element method was selected to evaluate the region suitability of GSHP system. The results show that the suitable area is 559. 63 km2 for utilizing GSHP in the studied area,accounting for 62. 58% of the total area; while the unsuitable area is 334. 60 km2,accounting for37.42%. The evaluating results can provide not only a scientific basis for development and utilization rationally of shallow geothermal heat in Baotou,but also offer an important reference to the other areas.展开更多
Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to d...Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.展开更多
Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with ti...Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%.展开更多
In this paper, the operation strategy of an energy storage ground source heat pump project in Beijing is studied, and the heat balance of the ground source heat pump is analyzed and calculated under the existing opera...In this paper, the operation strategy of an energy storage ground source heat pump project in Beijing is studied, and the heat balance of the ground source heat pump is analyzed and calculated under the existing operation strategy. The research shows that after the ground source heat pump system has been in operation for one year, the temperature rise of geological body in the hole distribution area is about 0.34℃, considering the influence of formation lithology, scattered hole distribution, abundant site, groundwater runoff and other factors on the heat dissipation of geological body, and the intermission of the heat pump air conditioning system is also beneficial to the recovery of the temperature of geological body. It can be considered that the ground heat pump system has little impact on the temperature of the rock and soil mass, and the project has good sustainability.展开更多
According to the specific situation of a general hospital project, this paper analyzes the feasibility of the application of ground source heat pump air conditioning in the project from the conditions, one-time invest...According to the specific situation of a general hospital project, this paper analyzes the feasibility of the application of ground source heat pump air conditioning in the project from the conditions, one-time investment, energy consumption and operating costs of the implementation of ground source heat pump air conditioning, and comprehensively expounds several important technical measures of the implementation of ground source heat pump air conditioning. Combined with the characteristics of this project, the operation strategies of ground source heat pump air conditioning system under summer cooling condition, winter heating condition and over season condition are designed and put forward to ensure that the ground source heat pump air conditioning system can achieve the expected design effect and energy saving and emission reduction benefits.展开更多
Abandoned mines are rich in geothermal resources.In this article,the feasibility of applying a water resource heating system in abandoned mines is explored,adopting mine water in the extraction zone as the research ob...Abandoned mines are rich in geothermal resources.In this article,the feasibility of applying a water resource heating system in abandoned mines is explored,adopting mine water in the extraction zone as the research object.First,the utilization mode of geothermal resources in abandoned mines is introduced,and the applicable scenarios of different mine water heating methods are clarified.Second,to prevent the heat transfixion phenomenon caused by an irrational arrangement of pumping wells,a three-dimensional numerical calculation model for multiphysical field coupling of the pumping wells of a water source heat pump in abandoned mines is established,and 14 distinct types of well arrangements are simulated.According to the occurrence degree of heat transfixion,the most reasonable arrangement of pumping wells is selected.The influences of different recharge tempera-tures,pumping and recharging flow rates,well spacings,hydraulic gradients,aquifer thicknesses,porosities and other factors on the pumping temperature are studied according to the selected pumping and recharging well arrangement scheme.Finally,by choosing a residential building as the analysis object,a simulation model of the abandoned mine water source heat pump heating system is constructed,which is compared with a gas boiler heating system,revealing the energy savings and environmental protection benefits of the abandoned mine water source heat pump system.The results of this paper provide a scientific basis for the utilization of mine water geothermal resources,which can facilitate the transformation of abandoned mines and provide theoretical and technical guidance in engineering practice.展开更多
基金supported by 2024 Central Guidance Local Science and Technology Development Fund Project"Study on the mechanism and evaluation method of thermal pollution in water bodies,as well as research on thermal carrying capacity".(Grant 246Z4506G)Key Research and Development Project in Hebei Province:"Key Technologies and Equipment Research and Demonstration of Multiple Energy Complementary(Electricity,Heat,Cold System)for Solar Energy,Geothermal Energy,Phase Change Energy"(Grant 236Z4310G)the Hebei Academy of Sciences Key Research and Development Program"Research on Heat Transfer Mechanisms and Efficient Applications of Intermediate and Deep Geothermal Energy"(22702)。
文摘Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,in certain regions,the installation of buried pipes for heat exchangers may be complicated,and these pipes may not always serve as efficient low-temperature heat sources for the heat pumps of the system.To address this issue,the current study explored the use of solar-energy-collecting equipment to supplement buried pipes.In this design,both solar energy and geothermal energy provide low-temperature heat to the heat pump.First,a simulation model of a solar‒ground source heat pump coupling system was established using TRNSYS.The accuracy of this model was validated through experiments and simulations on various system configurations,including varying numbers of buried pipes,different areas of solar collectors,and varying volumes of water tanks.The simulations examined the coupling characteristics of these components and their influence on system performance.The results revealed that the operating parameters of the system remained consistent across the following configurations:three buried pipes,burial depth of 20 m,collector area of 6 m^(2),and water tank volume of 0.5 m^(3);four buried pipes,burial depth of 20 m,collector area of 3 m^(2),and water tank volume of 0.5 m^(3);and five buried pipes with a burial depth of 20 m.Furthermore,the heat collection capacity of the solar collectors spanning an area of 3 m^(2)was found to be equivalent to that of one buried pipe.Moreover,the findings revealed that the solar‒ground source heat pump coupling system demonstrated a lower annual cumulative energy consumption compared to the ground source heat pump system,presenting a reduction of 5.31%compared to the energy consumption of the latter.
基金the National Natural Science Foundation of China(No.51776117)。
文摘A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.
基金supported by the National Natural Science Foundation of China(Grant Nos.42001059,52178340)the Natural Science Foundation of Hebei Province,China(Grant No.E2020210044)+1 种基金the Key Laboratory of Mechanical Behavior Evolution and Control of Traffic Engineering Structures in Hebei(Grant No.SZ 2022-03)the Overseas Expertise Introduction Project for Discipline Innovation("111 Project",Grant No.B21011).
文摘This study introduces a novel artificial heating technique aimed at addressing frost heave issues in embankments on frozen ground,offering a sustainable solution.Initial evaluations assessed various heating systems,including boilers,heat pumps,solar heaters,and electric heaters,focusing on their thermal performance and applicability.The study subsequently designed and implemented a direct-expansion ground source heat pump(DX-GSHP)system as the primary heat source for embankment warming.Rigorous testing confirmed the DX-GSHP system's ability to maintain a heat-supply temperature above 40℃ and a heat-absorption temperature below -3.5℃,effectively extracting geothermal energy for transfer to the topsoil layers.With a demonstrated coefficient of performance(COP)of 3.49,the DX-GSHP system not only proves its energy efficiency but also suggests a potential role in reducing the strain on electricity supply systems.Installation of DX-GSHPs,with heating capacities ranging from 1.0 to 2.0 kW and spaced at intervals of 2.0-4.0 m,provides a rapid thermal response to frost heave in singletrack railway embankments,thereby potentially mitigating frost-induced damage in cold climate regions.
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B04)China Postdoctoral Science Foundation(No.20090461050)+1 种基金the Project of Researchand Development of Ministry of Housing and Urban-Rural Development ofChina(No.2008-K1-26)the New Century Talent Project of Yangzhou University for Excellent Young Backbone Teacher(2008)
文摘In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.
基金Project(50606007) supported by the National Natural Science Foundation of China
文摘To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.
基金Project(2006BAJ01B05) supported by the National Science and Technology Pillar Program during the 11th Five-Year Plane Period
文摘The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of building air conditioning load were considered.The results,compared with the constant flow operation,indicate that the influence on the variations of porosity,hydraulic conductivity and confined water head is decreased by 48%,51% and 71%,respectively,under variable flow operation.The security of variable flow operation is superior to that of constant flow.It is also concluded that the climate region and function of the buildings are primary factors which affect the suitability of variable flow operation in GWSHP.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProject(2010DFA72740-05) supported by the International Science & Technology Cooperation Program of China
文摘Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.
基金Supported bythe"11th Five-Year Plan"for National Plans of Major Technology Projects
文摘An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.
基金Project(2012BAJ06B04)supported by"12th Five-Year Plan"National science and Technology,ChinaProject(2014-228)supported by Department of Housing and Urban Rural Development of Hebei,China
文摘The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
基金supported by the Estonian Research Council,with Institutional research funding grant IUT1-15with the project“Development of efficient tech-nologies for air change and ventilation necessary for the increase of energy efficiency of buildings,AR12045”,financed by SA Archimedesby the project“Civil and Environmental Engineering PhD School,DAR9085”.
文摘This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP.
文摘To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.
基金the Science and Technology Program Project of the Ministry of Housing and Urban-Rural Development“Research on Indoor Thermal Environment Based on Zero Energy Building Technology in Hot Summer and Cold Winter Area”(2017-K1-014)Hubei Provincial Natural Fund Youth Fund“Technology and Evaluation of Multi-energy Complementary Energy Supply for Rural Residential Buildings in Hubei”(2017CFB311).
文摘Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%.
文摘The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the European project "Integration of Geothermal Energy Into Industrial Application - IGEIA", project number EIE 06/001, supported by the Intelligent Energy for Europe, IEE, of EACI, European Commission. In general for supermarkets installed in single buildings, the building envelope has higher rates of envelope areas per indoor air volume. In Portugal this fact produces high need of heating during the winter season and high cooling needs during the summer season. Inside the building there are strong internal heat loads produced by high densities of lights and equipments. However these internal loads are not distributed uniformly. There are some areas with high production of heat but there are others with production of cooling. Therefore the acclimatization of this kind of buildings is not so easy and the balance of heating and cooling needs is depending of different parameters which should be well evaluated. The energy consummation of the cold display cases and deep freezers in market area and storage is also very high. The different energy needs could be studied in an integrated way and could be partially satisfied by geothermal energy using ground source heat pumps. At the same time the boreholes could be used as an energy reservoir increasing the efficiency of whole system. Four different climatic zones in Portugal were selected, (north coast, interior north, south coast and interior south) using the same system. The results of the study show that the all energy needs can by partially satisfied by geothermal energy but they need to be integrated to increase the global efficiency. The paper shows that the geothermal energy can be an attractive application for the supermarkets in Portugal if the energy solution is studied in an integrated way and if it is also considered as a cost the emissions of CO2 avoid by the new system.
基金Supported by project of Shallow Geothermal Energy Survey of Inner Mongolia Baotou Plain(No.2010-3-SK35)
文摘According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP) were established in Baotou plain. The factor weights were determined by using analytic hierarchy process,and the comprehensive element method was selected to evaluate the region suitability of GSHP system. The results show that the suitable area is 559. 63 km2 for utilizing GSHP in the studied area,accounting for 62. 58% of the total area; while the unsuitable area is 334. 60 km2,accounting for37.42%. The evaluating results can provide not only a scientific basis for development and utilization rationally of shallow geothermal heat in Baotou,but also offer an important reference to the other areas.
文摘Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.
文摘Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%.
文摘In this paper, the operation strategy of an energy storage ground source heat pump project in Beijing is studied, and the heat balance of the ground source heat pump is analyzed and calculated under the existing operation strategy. The research shows that after the ground source heat pump system has been in operation for one year, the temperature rise of geological body in the hole distribution area is about 0.34℃, considering the influence of formation lithology, scattered hole distribution, abundant site, groundwater runoff and other factors on the heat dissipation of geological body, and the intermission of the heat pump air conditioning system is also beneficial to the recovery of the temperature of geological body. It can be considered that the ground heat pump system has little impact on the temperature of the rock and soil mass, and the project has good sustainability.
文摘According to the specific situation of a general hospital project, this paper analyzes the feasibility of the application of ground source heat pump air conditioning in the project from the conditions, one-time investment, energy consumption and operating costs of the implementation of ground source heat pump air conditioning, and comprehensively expounds several important technical measures of the implementation of ground source heat pump air conditioning. Combined with the characteristics of this project, the operation strategies of ground source heat pump air conditioning system under summer cooling condition, winter heating condition and over season condition are designed and put forward to ensure that the ground source heat pump air conditioning system can achieve the expected design effect and energy saving and emission reduction benefits.
基金supported by the Natural Science Foundation of Shandong Province,China(No.ZR2022ME079)the National Natural Science Foundation of China(Project No.52278115)the Plan of Guidance and Cultivation for Young Innovative Talents of Shandong Provincial Colleges and Universities.
文摘Abandoned mines are rich in geothermal resources.In this article,the feasibility of applying a water resource heating system in abandoned mines is explored,adopting mine water in the extraction zone as the research object.First,the utilization mode of geothermal resources in abandoned mines is introduced,and the applicable scenarios of different mine water heating methods are clarified.Second,to prevent the heat transfixion phenomenon caused by an irrational arrangement of pumping wells,a three-dimensional numerical calculation model for multiphysical field coupling of the pumping wells of a water source heat pump in abandoned mines is established,and 14 distinct types of well arrangements are simulated.According to the occurrence degree of heat transfixion,the most reasonable arrangement of pumping wells is selected.The influences of different recharge tempera-tures,pumping and recharging flow rates,well spacings,hydraulic gradients,aquifer thicknesses,porosities and other factors on the pumping temperature are studied according to the selected pumping and recharging well arrangement scheme.Finally,by choosing a residential building as the analysis object,a simulation model of the abandoned mine water source heat pump heating system is constructed,which is compared with a gas boiler heating system,revealing the energy savings and environmental protection benefits of the abandoned mine water source heat pump system.The results of this paper provide a scientific basis for the utilization of mine water geothermal resources,which can facilitate the transformation of abandoned mines and provide theoretical and technical guidance in engineering practice.